Brochure_brute_ft_floor_standing_combi_brtftfl Brochure Brute Ft Floor Standing Combi Brtftfl
2019-02-26
: Bradfordwhite Brochure Brute Ft Floor Standing Combi Brtftfl brochure_brute_ft_floor_standing_combi_brtftfl uploads wp-content
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
F I R E T U B E T E C H N O L O G Y Floor Standing Combination Boiler & Water Heater 95% Efficient (AFUE) 10:1 Modulation Environmentally Friendly Low NOx Emissions Integrated Indirect Tank for Superior DHW Performance Vent up to 100 ft. in PVC, CPVC & Polypropylene Field Convertible to LP Easily! ENERGY STAR® Rated High Efficiency Fire Tube Combi Boiler The Brute FT ® is a combination (“Combi” - heating and domestic hot water) floor standing boiler packed with features. It easily satisfies the heating and hot water needs of the modern home. Powering the Brute FT® is an advanced fire tube heat exchanger that uses the latest in heating tube technology. Advanced Straightforward Controls Every Brute FT® is equipped with the Advanced Integrated Control System • Easy–to–use dial and push button input system with large backlit display • Functions are clearly displayed for quick set-up and diagnostics • Quick access buttons for temperature control and boiler status functions • Outdoor reset feature for fuel savings Saves You Money Greatly reduces heating bills when compared to older, mid-efficient boilers - up to 20%. • 95% efficiency (AFUE) equals lower fuel use • Outdoor reset technology balances your home’s heating needs with the outside temperature • Brute FT® modulates to a lower firing rate during cool days to reduce fuel use even further • ENERGY STAR® Qualified and Rebate Eligible. Enough Hot Water for Everyone The Bradford White Brute FT® uses a condensing The indirect tank makes sure you have an heat exchanger and integrated indirect tank design that combines the best of space and domestic water heating into one compact system. The indirect tank is kept charged with three gallons of hot water, always on standby to ensure that you abundance of hot water quickly and the boiler makes sure you never run out of hot water for as long as you need it! have ample hot water available as fast as possible. When the stored hot water begins to be used by your faucet, shower, etc., the boiler fires and immediately begins to produce more hot water. The best of both worlds! Hot water fast and an endless supply – never run out again. Reliable & Innovative Design Automatic Air Elimination Valve High Performance Blower Allows for a quiet, clean combustion and a wide range of venting options. Clean Burning Burner Uses fuel efficiently and produces ultra low NOx and CO emissions. Modulating Gas Valve Field convertible to LP. Brute FT® Integrated Control • Outdoor Reset • Conformal coating encapsulates control board protecting it from moisture • Dual stage anti-freezing mechanism • Built-in gas leak detection (alarm will activate and the unit will shut down if a leak is detected) Advanced Fire Tube Heat Exchanger Provides maximum efficiency and excellent heat transfer. Condensate Trap Central Heat Circulator Domestic Water Circulator Separate, dedicated circulators optimize high performance and reliability. Domestic Hot Water Heat Exchanger By combining both storage and recovery capacity, the Brute FT® Domestic Hot Water heat exchanger bridges the comfort gap between instantaneous and tanktype water heating equipment. • Provides immediate response to demand • Hot boiler water inside the tank provides immediate recovery • Heated in a coiled, corrugated stainless tube contained in a heavily-insulated stainless tank • Inside the tank, 158°F boiler water surrounds the domestic hot water coil • Contains approximately three gallons of storage Brute FT® Specifications SPECIFICATION Input, Max Fire Output, Max Fire Turndown Efficiency / Energy Factor Fuel UNITS / CONDITION Minimum Flow Rate MBH (kW) MBH (kW) — AFUE — 35˚F Temp Rise – GPM (l/m) 45˚F Temp Rise – GPM (l/m) 77˚F Temp Rise – GPM (l/m) GPM (l/m) Gas Supply Pressure (In WC) Pressure Relief Settings psi (kPa) Vent Diameter / Eq Length* lbs. / ft DHW Flow Rate Vent Material Power Supply Weight Unit Weight Shipping (Est.) Dimensions (W x H x L) Warranty — Volts / Hertz lbs. (kg) lbs. (kg) inches — BMFTCF199 199 (58) 189 (55) 10:1 95% Natural Gas or Propane 9.9 (38) 7.7 (29) 4.8 (18) 0.5 (1.9) Natural Gas - Min 3.5/ Max 10.5 Propane - Min 8.0 / Max 13.0 30 (207) 2” / 50’* 3” / 100’ PVC, CPVC, Polypropylene 120 / 60 180 (82) 242 (91) 15.7 x 53.7 x 26.7 Limited 10 Year Warranty Item A B C D E F G I O Description Gas Inlet Connection (NPT) 199 MBH Space Heating 'CH' Supply (NPT) Space Heating 'CH' Return (NPT) DHW Outlet (NPT) DHW Inlet (NPT) Condensate Line (NPT) Drain Line (NPT) Air Intake Collar Exhaust Outlet Pipe Collar Diameter 3/4" 1" 1" 3/4" 3/4" 1/2" 1/2" 3” 3” BMFTCF199 H L W 53.7" (134 cm) 26.7" (68 cm) 15.7" (40 cm) *Propane models vent limited to 25 equivalent feet in length. For field service, contact your professional installer or local Bradford White sales representative. Sales 800-523-2931 • Fax 215-641-1612 Technical Support 800-334-3393 • Email techserv@bradfordwhite.com Warranty 800-531-2111 • Email warranty@bradfordwhite.com International: Telephone 1-215-641-9400 • Email international@bradfordwhite.com / www.bradfordwhite.com ©2019 Bradford White Corporation. All rights reserved. BRTFTFL BRO 0119
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c016 91.163616, 2018/10/29-16:58:49 Create Date : 2019:02:26 12:22:18-05:00 Metadata Date : 2019:02:26 12:23:01-05:00 Modify Date : 2019:02:26 12:23:01-05:00 Creator Tool : Adobe InDesign CC 14.0 (Macintosh) Instance ID : uuid:924c4bbd-52da-ea4b-b449-993799ed0312 Original Document ID : xmp.did:1a35429e-1ab1-43e3-b140-5157f03ec335 Document ID : xmp.id:91920245-9489-45ca-97c6-60e04ecd4beb Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:46995679-cf5b-497a-a913-0fc9e2ce5aa8 Derived From Document ID : xmp.did:6bb6d6a6-e575-461d-828c-f288a6558891 Derived From Original Document ID: xmp.did:1a35429e-1ab1-43e3-b140-5157f03ec335 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 14.0 (Macintosh) History Changed : / History When : 2019:02:26 12:22:18-05:00 Format : application/pdf Title : brochure_brute_ft_floor_standing_combi_brtftfl.pdf Creator : Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 4 Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools