F I R E

T U B E

T E C H N O L O G Y

Floor Standing Combination
Boiler & Water Heater

95% Efficient (AFUE)
10:1 Modulation
Environmentally Friendly
Low NOx Emissions
Integrated Indirect Tank for
Superior DHW Performance
Vent up to 100 ft. in PVC,
CPVC & Polypropylene
Field Convertible to LP Easily!
ENERGY STAR® Rated

High Efficiency Fire Tube Combi Boiler
The Brute FT ® is a combination (“Combi” - heating and domestic hot water)
floor standing boiler packed with features. It easily satisfies the heating and hot
water needs of the modern home.
Powering the Brute FT® is an advanced fire tube heat exchanger that uses the
latest in heating tube technology.

Advanced Straightforward Controls
Every Brute FT® is equipped with the Advanced Integrated Control System
• Easy–to–use dial and push button input system with large backlit display
• Functions are clearly displayed for quick set-up and diagnostics
• Quick access buttons for temperature control and boiler status functions
• Outdoor reset feature for fuel savings

Saves You Money
Greatly reduces heating bills when compared to older, mid-efficient boilers - up to 20%.
• 95% efficiency (AFUE) equals lower fuel use
• Outdoor reset technology balances your home’s heating needs with the outside temperature
• Brute FT® modulates to a lower firing rate during cool days to reduce fuel use even further
• ENERGY STAR® Qualified and Rebate Eligible.

Enough Hot Water for Everyone
The Bradford White Brute FT® uses a condensing

The indirect tank makes sure you have an

heat exchanger and integrated indirect tank design
that combines the best of space and domestic
water heating into one compact system. The
indirect tank is kept charged with three gallons of
hot water, always on standby to ensure that you

abundance of hot water quickly and the boiler
makes sure you never run out of hot water for as
long as you need it!

have ample hot water available as fast as possible.
When the stored hot water begins to be used by
your faucet, shower, etc., the boiler fires and
immediately begins to produce more hot water.

The best of both worlds! Hot water fast and an
endless supply – never run out again.

Reliable & Innovative Design

Automatic Air Elimination Valve

High Performance Blower
Allows for a quiet, clean combustion
and a wide range of venting options.

Clean Burning Burner
Uses fuel efficiently and
produces ultra low NOx and
CO emissions.

Modulating Gas Valve
Field convertible to LP.

Brute FT® Integrated Control
• Outdoor Reset
• Conformal coating encapsulates control
board protecting it from moisture
• Dual stage anti-freezing mechanism
• Built-in gas leak detection (alarm will
activate and the unit will shut down
if a leak is detected)

Advanced Fire Tube Heat
Exchanger
Provides maximum efficiency and
excellent heat transfer.

Condensate Trap

Central Heat Circulator
Domestic Water Circulator
Separate, dedicated circulators
optimize high performance
and reliability.

Domestic Hot Water Heat Exchanger
By combining both storage and recovery capacity, the Brute FT® Domestic Hot
Water heat exchanger bridges the comfort gap between instantaneous and tanktype water heating equipment.
• Provides immediate response to demand
• Hot boiler water inside the tank provides immediate recovery
• Heated in a coiled, corrugated stainless tube contained in a heavily-insulated
stainless tank
• Inside the tank, 158°F boiler water surrounds the domestic hot water coil
• Contains approximately three gallons of storage

Brute FT® Specifications
SPECIFICATION
Input, Max Fire
Output, Max Fire
Turndown
Efficiency / Energy Factor
Fuel

UNITS / CONDITION

Minimum Flow Rate

MBH (kW)
MBH (kW)
—
AFUE
—
35˚F Temp Rise – GPM (l/m)
45˚F Temp Rise – GPM (l/m)
77˚F Temp Rise – GPM (l/m)
GPM (l/m)

Gas Supply Pressure

(In WC)

Pressure Relief Settings

psi (kPa)

Vent Diameter / Eq Length*

lbs. / ft

DHW Flow Rate

Vent Material
Power Supply
Weight Unit
Weight Shipping (Est.)
Dimensions (W x H x L)
Warranty

—
Volts / Hertz
lbs. (kg)
lbs. (kg)
inches
—

BMFTCF199
199 (58)
189 (55)
10:1
95%
Natural Gas or Propane
9.9 (38)
7.7 (29)
4.8 (18)
0.5 (1.9)
Natural Gas - Min 3.5/ Max 10.5
Propane - Min 8.0 / Max 13.0
30 (207)
2” / 50’*
3” / 100’
PVC, CPVC, Polypropylene
120 / 60
180 (82)
242 (91)
15.7 x 53.7 x 26.7
Limited 10 Year Warranty

Item
A
B
C
D
E
F
G
I
O

Description
Gas Inlet Connection (NPT) 199 MBH
Space Heating 'CH' Supply (NPT)
Space Heating 'CH' Return (NPT)
DHW Outlet (NPT)
DHW Inlet (NPT)
Condensate Line (NPT)
Drain Line (NPT)
Air Intake Collar
Exhaust Outlet Pipe Collar

Diameter
3/4"
1"
1"
3/4"
3/4"
1/2"
1/2"
3”
3”

BMFTCF199
H
L
W

53.7" (134 cm)
26.7" (68 cm)
15.7" (40 cm)

*Propane models vent limited to 25 equivalent feet in length.

For field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 • Fax 215-641-1612
Technical Support 800-334-3393 • Email techserv@bradfordwhite.com
Warranty 800-531-2111 • Email warranty@bradfordwhite.com
International: Telephone 1-215-641-9400 • Email international@bradfordwhite.com / www.bradfordwhite.com

©2019 Bradford White Corporation. All rights reserved.
BRTFTFL BRO 0119



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c016 91.163616, 2018/10/29-16:58:49
Create Date                     : 2019:02:26 12:22:18-05:00
Metadata Date                   : 2019:02:26 12:23:01-05:00
Modify Date                     : 2019:02:26 12:23:01-05:00
Creator Tool                    : Adobe InDesign CC 14.0 (Macintosh)
Instance ID                     : uuid:924c4bbd-52da-ea4b-b449-993799ed0312
Original Document ID            : xmp.did:1a35429e-1ab1-43e3-b140-5157f03ec335
Document ID                     : xmp.id:91920245-9489-45ca-97c6-60e04ecd4beb
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:46995679-cf5b-497a-a913-0fc9e2ce5aa8
Derived From Document ID        : xmp.did:6bb6d6a6-e575-461d-828c-f288a6558891
Derived From Original Document ID: xmp.did:1a35429e-1ab1-43e3-b140-5157f03ec335
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 14.0 (Macintosh)
History Changed                 : /
History When                    : 2019:02:26 12:22:18-05:00
Format                          : application/pdf
Title                           : brochure_brute_ft_floor_standing_combi_brtftfl.pdf
Creator                         : 
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 4
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu