eF Series
Ultra High Efficiency
Commercial Gas Water Heaters
®

Bradford White’s eF Series

®

The celebrated eF Series® is one of the many
exceptional performers in Bradford White’s
commercial line-up.
Utilizing exclusive designs and technologies, this

time-tested top performer outclasses the competition
when it comes to installation

flexibility, quiet operation, and,

most importantly, efficiency. The
eF Series provides year-round
®

energy and money savings while

meeting your toughest installation

challenges and hot water demands.

Highlights
• Fully Condensing Design
• ICON HD™ Commercial Control System
• High Recovery Rates
• ENERGY STAR® Models Available—EF60T125 &
EF100T (150, 199, 250, 399) Models
• Reliable Trouble–Free Performance
• Down-Fired Premix Power Burner Automatically
Adjusts up to 10,000 ft. above Sea Level
• Meets California Ultra Low NOx Requirements
• Ultra Quiet Operation
• Zero Inch Clearance to Combustible Materials

The Best All-Around
Efficiency
TheUltra
Best High
All-Around
Ultra High Efficienc

®
®
Powerful
and and
proven
performers,
eF Series
Ultra High
Efficiency
Powerful
proven
performers,
eF Series
Ultra
High Effi
water heaters are known for incredible delivery and super-fast
delivery and super-fast recovery, making them the best al
recovery, making them the best all-around Ultra High Efficiency
®
in the
industry.
eF Series
– Built to satisfy your toughe
Water
Heaters
in theThe
industry
.

Sequence of Operation
1

2

Combustion gases generated by
the Premix Power Burner travel
through three heat exchangers.
The combustion gases enter the
1st pass heat exchanger at a
temperature above 2000°F and
then travel down the 8" heat
exchanger tube.

3

When the combustion
gases reach the 1st
pass collector at a
temperature near
1100°F, the gases are
then redirected upwards
into two 4" 2nd pass
heat exchanger tubes.

4

The gases
then move into
the 2nd pass
collector, where
the temperature
has now been
reduced down
to approximately
500°F.

The combustion
gases are then forced
downward through
eight 2" 3rd pass
heat exchanger
tubes and reach the
exhaust collector
at a temperature of
approximately 120°F.

Venting Options
•

*

Flexible Venting up to 240 ft.

•

*

•

Optional Concentric Vent Termination
Kit – available in 2" or 3"

Ability to vent with 2", 3", 4" or 6" PVC,
CPVC, ABS or PP Pipe (Canada must
use specific ULC S636 vent material)

*Review, spec sheet and manual for venting limitations.

Power Vent – using inside
air for combustion,
venting vertically
through the roof or
horizontally through
the wall

Dire
o
c
v
h
e
t

Water Heater in the Industry

Efficiency Water Heater in the Industry

®
a High Effi
water
heaters
are your
known
for incredible
Theciency
eF Series
– Built
to satisfy
toughest
hot water
he bestrequirements.
all-around Ultra High Efficiency Water Heaters

our toughest hot water requirements.

The extensive commercial
eF Series® line-up will help you
meet the demands of any job,
including those found in hotels,
motels, restaurants, medical
centers, schools, apartments,
health clubs, stadiums, office
buildings, shopping centers,
laundromats, and more.

Free eF Series® Efficiency
Calculator App

orced
ugh
s

the
or
e of
20°F.

Scan the QR code to download any of our FREE Apps!
iPad/iPhone & Android Compatible

Direct Vent – using
outside air for
combustion either
vertically or
horizontally and
exhausting through
the wall or roof

•

Calculate the savings of
eF Series® Ultra High
Efficiency Water Heaters.

•

See daily and yearly energy
and cost savings.

Unbalanced Direct Vent –
using outside air for
combustion, where the air
intake pipe doesn’t have to
be the same length or the
same external building
surface as the
exhaust vent

The eF Series
Exclusive Technologies and Features
®

Down-Fired Premix
Power Burner
• Proven design with
over 10 years of use
in the field
• Self-compensating
negative pressure
system
• Automatically
regulates fuel flow
when a change in
combustion air is
detected
• Optimum combustion
and efficiency
• Automatically adjusts
for altitudes up to
10,000 feet
• Single Exhaust
Pressure Switch*

ICON HD™ Commercial
Control System
• Features an LCD
digital display showing
temperature set point and
diagnostic codes
to aid in servicing and
troubleshooting
• User-friendly touchpad
and easily viewable
data display area

Three Pass Heat
Exchanger System
• Provides maximum heat
transfer surface area
• Allows combustion gas to
move at high velocity

Submerged
Combustion Chamber
• Minimizes radiant heat
loss and improves
efficiency

Hydrojet® Sediment
Reduction System
• Helps prevent sediment
buildup inside the tank

*EF100T399 features an additional
pressure switch for intake.
RD

FO
BRAD

Scan the QR
code to see the
eF Series video!
®

HI

ORPORA
TE C
TI

O

N

W

Advantages
Specifiers

Installers

Building Owners

With high recovery rates and
exceptional installation flexibility,
the eF Series® is an outstanding
eco-friendly option that can meet
the toughest installation challenges
and hot water demands.

The design of this product allows
for exceptional installation flexibility
with many different venting options.
With our exclusive ICON HD™
Commercial Control System, the
LCD display and diagnostic codes
aid in servicing and troubleshooting.

If energy savings and ultra quiet
operation are important to you, look
no further. The eF Series® utilizes
exclusive designs for unsurpassed
reliability, efficiency, and quiet
operation. Most models are
ENERGY STAR® qualified.

Specs at a Glance
3/4"

3" PVC INLET

NPT GAS INLET

B

GAS INLET

81/4"
EXHAUST

11/2" NPT OUTLET

81/4"
AIR INTAKE

A

T&P VALVE

H

CLEANOUT

E

1" NPT SPACE
HEATING OUTLET

G

1" NPT SPACE
HEATING RETURN

C

11/2" NPT INLET

D

F
3/4" O.D.

3" PVC EXHAUST

21/2" MIN.

NATURAL GAS AND LIQUID PROPANE GAS
Model
Number

Capacity

U.S. Imp.
Gal. Gal.
EF-60T-125E-3N(A)
EF-60T-150E-3N(A)
EF-60T-199E-3N(A)
EF-100T-150E-3N(A)
EF-100T-199E-3N(A)
EF-100T-250E-3N(A)
EF-100T-300E-3N(A)
EF-100T-399E-3N(A)

60
60
60
100
100
100
100
100

50
50
50
83
83
83
83
83

Input

GPH Recovery
at Degree Rise*

Nat.
BTU/Hr.
Input

LP
BTU/Hr.
Input 40°F 100°F 140°F

125,000
150,000
199,999
150,000
199,999
250,000
300,000
399,999

125,000
150,000
199,999
150,000
199,999
250,000
300,000
399,999

364
423
558
450
597
735
836
1127

145
169
223
180
239
294
335
451

A
Floor
to
Top of
Heater
in.

B
Jacket
Dia.

57
57
57
775/8
775/8
775/8
775/8
775/8

281/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4

104
121
159
129
171
210
239
322

in.

G
H
Water Gas Relief Approx. Energy
C
D
E
F
Floor Floor Floor Floor Floor to Floor Conn. Conn. Valve Shipping Star®
Air
to
Dia.
Dia. Open Weight Qualified
to Hot to Cold
to
to
Water Water Gas Vent Intake T&P
Conn. Conn. Conn. Conn. Conn. Conn.
in.
in.
in.
in.
in.
in.
in.
in.
in.
lbs.
421/2
421/2
421/2
621/2
621/2
621/2
621/2
63

12 7/8
12 7/8
12 7/8
12 7/8
12 7/8
12 7/8
12 7/8
13

531/2
531/2
531/2
743/4
743/4
743/4
743/4
741/4

5
5
5
5
5
5
5
5

521/2
521/2
521/2
731/8
731/8
731/8
731/8
731/8

40
40
40
60
60
60
60
60

11/2
11/2
11/2
11/2
11/2
11/2
11/2
11/2

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

1
1
1

3/4

1

570
570
570
900
900
900
900
950

Yes
Yes
Yes
Yes
Yes

(A) = ASME Code Available. Capacity
F
Input
LPH Recovery Therm.
A
B
C
D
E
G
H
Water Gas Relief Approx.
Model
For Propane
Gas models change suffix "N" to "X" and remove "E" from the model
number.Rise*
Example: EF-100T-150-3X.
Floor and
at Degree
Eff.
Floor Jacket Floor Floor Floor
Floorspecifi
to Floor
Conn.
Conn.
Valve without
Shipping
Dimensions
cations
subject
to change
notice in
Number
All models
comply with SCAQMD low NOx requirements.
to
to
Dia. to Hot to Cold
to
Air
to
Dia.
Dia. Open Weight
accordance
our policy
Please consult specification sheet and website for complete
Vent with
LP information.
Nat. product
Top of
Water Water Gas
Intake
T&P of continuous product improvement.

EF-60T-125E-3N(A)
EF-60T-150E-3N(A)
EF-60T-199E-3N(A)
EF-100T-150E-3N(A)
EF-100T-199E-3N(A)
EF-100T-250E-3N(A)
EF-100T-300E-3N(A)
EF-100T-399E-3N(A)

Liters

kW/Hr.
Input

kW/Hr.
Input

227
227
227
379
379
379
379
379

36.6
43.9
58.6
43.9
58.6
73.2
87.9
117.2

36.6
43.9
58.6
43.9
58.6
73.2
87.9
117.2

22°C 56°C 78°C
1378
1601
2112
1703
2260
2782
3165
4266

549
640
844
681
905
1113
1268
1707

394
458
602
488
647
795
905
1219

%
96.0
93.0
92.0
99.1
98.5
97.0
92.0
94.0

Heater
mm. mm.
1448
1448
1448
1972
1972
1972
1972
1972

718
718
718
718
718
718
718
718

Conn.
mm.
1087
1087
1087
1588
1588
1588
1588
1600

Conn. Conn. Conn. Conn. Conn.
mm. mm. mm. mm. mm.
327
327
327
327
327
327
327
330

1359
1359
1359
1899
1899
1899
1899
1861

127
127
127
127
127
127
127
127

1334
1334
1334
1857
1857
1857
1857
1857

1016
1016
1016
1524
1524
1524
1524
1524

mm.

mm.

mm.

kgs.

38
38
38
38
38
38
38
38

19
19
19
19
19
19
19
25

19
19
19
19
19
25
25
25

259
259
259
408
408
408
408
431

Committed to the Professional.
©2017, Bradford White Corporation. All rights reserved.

EFB-1017

www.bradfordwhite.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161210, 2017/08/11-10:28:36
Create Date                     : 2017:10:31 12:39:43-04:00
Metadata Date                   : 2017:10:31 12:39:50-04:00
Modify Date                     : 2017:10:31 12:39:50-04:00
Creator Tool                    : Adobe InDesign CC 13.0 (Macintosh)
Instance ID                     : uuid:2354361e-5a55-df48-9a5b-4dd88e9263e9
Original Document ID            : xmp.did:1a35429e-1ab1-43e3-b140-5157f03ec335
Document ID                     : xmp.id:18b4418a-4e9b-462b-b0db-ae93f8b269cc
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:50566a62-fda9-4923-b3a2-2a948af1018f
Derived From Document ID        : xmp.did:c0b4ef6b-a188-4acd-96f8-0390ffae5237
Derived From Original Document ID: xmp.did:1a35429e-1ab1-43e3-b140-5157f03ec335
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.0 (Macintosh)
History Changed                 : /
History When                    : 2017:10:31 12:39:44-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Slug Family                     : Helvetica Neue
Slug Version                    : 001.000
Slug Outline File Size          : 30129
Slug Kerning Checksum           : 48549
Slug Foundry                    : Adobe Systems
Slug Font Kind                  : PostScript
Slug Checksum                   : 1656855035
Slug Post Script Name           : HelveticaNeue-BoldExt
Slug Font Sense 12 Checksum     : 1656855035
Page Count                      : 6
Creator                         : Adobe InDesign CC 13.0 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu