Bradfordwhite Canada Residential Gas Natural Atmospheric Vent Damper High Efficiency D4 Quebec Specsheet 120 I User Manual

Residential Gas Natural Atmospheric Vent Damper High Efficiency D4 Prior Naeca Archived Specsheet 120B residential_gas_natural_atmospheric_vent_damper_high_efficiency_d4_prior_naeca_archived_specsheet_120b residential_gas_natural_atmospheric_vent_damper_high_efficiency_d4_prior_naeca_archived_specsheet_120b uploads wp-content bradfordwhitecorp :

2017-01-09

User Manual: Bradfordwhite Canada Residential Gas Natural Atmospheric Vent Damper High Efficiency D4 Quebec Specsheet 120 canada_residential_gas_natural_atmospheric_vent_damper_high_efficiency_d4_quebec_specsheet_120 uploads wp-content bradfordwhitecorp :

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadBradfordwhite Canada Residential Gas Natural Atmospheric Vent Damper High Efficiency D4 Quebec Specsheet 120 I User Manual
Open PDF In BrowserView PDF
Residential Damper Atmospheric Vent
High EF Energy Saver Gas Water Heater
The Damper High EF FVIR Defender Safety System® Models Feature:

Photo is of
D-4-403S6FBN
FEATURING:

■ ENERGY STAR® Qualified—These models qualify for the September 1st, 2010
minimum ENERGY STAR® EF requirement, as well as most utility rebate programs.
■ Bradford White ICON System™—Intelligent gas control with spark to pilot ignition
system eliminates the constant burning pilot. This results in savings of pilot gas during
stand by periods (120 V.A.C.).
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Delivery
ratings and tighter temperature differentials.
-- Advanced Temperature Control System—Microprocessor constantly monitors
and controls burner operation to maintain consistent and accurate water temperature
levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer during
start-up and provides ten different diagnostic codes to assist in troubleshooting.
-- Separate Immersed Thermowell—High strength advanced polymer composite
thermowell provides isolation between electric temperature sensor and surrounding
water. No need to drain the tank when removing gas valve.
■ Compatible With Optional Accessory Packages—Performance Package,
Protection Package and Inlet Shut-Off Valve Packages.
■ Automatic Flue Damper—Reduces stand-by heat loss, resulting in less gas
consumption, higher energy factor ratings and improved overall efficiency.
-- Flexible line cord and plug included (120 V.A.C.).
■ Advanced ScreenLok® Technology Flame Arrestor Design—Flame arrestor is
designed to prevent ignition of flammable vapor outside of the water heater.
■ Flammable Vapor Sensor—Electronic sensor prevents burner operation if
flammable vapors are detected.
■ Maintenance Free—No regular cleaning of air inlet openings or flame arrestor is
required under normal conditions.
■ Sight Window—Offers a view into the combustion chamber to observe the
operation of the pilot and burner.
■ Factory Installed Hydrojet® Total Performance System—Cold water inlet sediment
reducing device helps prevent sediment build up in tank. Increases first hour delivery of
hot water while minimizing temperature build up in tank.
■ Vitraglas® Lining—Bradford White tanks are lined with an exclusively engineered
enamel formula that provides superior tank protection from the highly corrosive effects
of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a
temperature of over 1600°F (871°C).
■ 2" Non-CFC Foam Insulation—Covers the side and top, reducing the amount of
heat loss. This results in less energy consumption, improved operation efficiencies
and jacket rigidity.
■ Pedestal Base.
■ Water Connections—3⁄4" NPT factory installed true dielectric fittings.
■ Factory Installed Heat Traps—Design incorporates a flexible disk that reduces heat
loss in piping and eliminates the potential for noise generation.
■ Protective Magnesium Anode Rod.
■ 3x4 “Snap Lock” Draft Diverter—Allows either 3" or 4" vent connections.
■ T&P Relief Valve—Installed.
■ Low Restriction Brass Drain Valve—Durable tamper proof design.

6 or 10-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171;
(B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534;
7,270,087 B2. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271
Defender Safety System®, Vitraglas®, Hydrojet®, and ScreenLok® are registered trademarks of Bradford White® Corporation.

120-B-0413-A

Residential Atmospheric Vent Gas Water Heater
Damper High EF Energy Saver Models

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery Efficiency

NATURAL GAS AND LIQUID PROPANE GAS
Model
Number

D-4-403S6FBN
D-4-504S6FBN
Model
Number

D-4-403S6FBN
D-4-504S6FBN

Capacity

U.S.
Gal.

Imp.
Gal.

40
50

42
33

Recovery*
90°F Rise
Nat.
LP
Nat.
BTU/Hr. BTU/Hr. U.S.
Input
Input
GPH

Nat.
Imp.
GPH

LP
U.S.
GPH

LP
Imp.
GPH

38,000
40,000

33
34

40
42

33
34

38,000
40,000

Capacity

40
42

Recovery*
50°C Rise

Liters

Nat.
kW
Input

LP
kW
Input

Nat.
Liters/
Hour

LP
Liters/
Hour

151
189

11.1
11.7

11.1
11.7

148
155

148
155

A
Floor to
Flue
Conn.

B
Jacket
Dia.

C
Vent
Size

D
Floor to
T&P
Conn.

F
G
E
Floor to Floor to Floor to
Top of
Water
Gas
Conn.
Conn. Heater

H
Depth

Approx.
Shipping
Weight

in.

in.

in.

in.

in.

in.

in.

in.

lbs.

553/4
641/2

22
22

3x4
3x4

411/2
50

113/4
113/4

48
57

49
573/4

263/4
263/4

151
170

A
Floor to
Flue
Conn.

B
Jacket
Dia.

C
Vent
Size

D
Floor to
T&P
Conn.

F
G
E
Floor to Floor to Floor to
Top of
Water
Gas
Conn.
Conn. Heater

H
Depth

Approx.
Shipping
Weight

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

kg.

1416
1638

559
559

76
76

1257
1270

298
298

1219
1448

1245
1467

679
679

68
77

Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "BN" to "SX".
For 10 year models, change suffix from “6” to “10”.
*Based on manufacturers rated recovery efficiency.
115V, 60Hz. 12 Amps.

Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3⁄4" NPT
(19mm) on 11" (279mm) centers. All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating. See AHRI for current Energy Factor ratings.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable side of this system. The potable side may NEVER be
connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.

Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.

Sales 800-523-2931 ● Fax 215-641-1670 / Technical Support 800-334-3393 ● Fax 269-795-1089 ● Warranty 800-531-2111 ● Fax 269-795-1089
International: Telephone 215-641-9400 ● Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 ● Fax 905-238-0105 / www.bradfordwhite.com

©2013, Bradford White Corporation. All rights reserved.

120-B-0413-A

Printed in U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/postscript
Creator                         : BennettC
Title                           : I:\ECO\7454\04-41 LINE DRAWING Layout1 (1)
Creator Tool                    : Adobe Illustrator CS2
Create Date                     : 2013:04:11 12:51:02-04:00
Modify Date                     : 2013:04:11 12:51:02-04:00
Metadata Date                   : 2010:06:28 16:32:15-04:00
Thumbnail Width                 : 256
Thumbnail Height                : 176
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 8425 bytes, use -b option to extract)
Document ID                     : uuid:6F3C3CA7F08C11DE98B490A0049609D7
Instance ID                     : uuid:5e8df8c1-dddb-7944-8f72-8b6d1c934774
Derived From Document Name      : uuid:086b974c-5665-4624-a4fe-d7ef5ea11f97
Derived From Instance ID        : uuid:5ebffe93-5da9-40cc-9022-5070fd3d5a27
Derived From Document ID        : uuid:4330a395-ebcc-422c-9fa2-4661c87e2a01
Producer                        : Acrobat Distiller 10.1.5 (Macintosh)
Page Count                      : 2
Author                          : BennettC
EXIF Metadata provided by EXIF.tools

Navigation menu