The Commander Series Models feature:
ICON HDThe proven design of an intelligent Honeywell® Integrated Control
combines temperature control, diagnostic codes, and system functions and
status into a single control with a digital LCD display.
-- Operation Mode—Simple, intuitive temperature adjustment up to
180°F/82°C. The user can easily select between Fahrenheit and Celsius.
-- Service Mode—The display has a “Service Mode” for changing the
maximum setpoint and accessing information that may aid in the service of
the water heater. These eight digitally displayed service screens can be easily
cycled through by pressing the select button. The service screens include:
max setpoint value, water temperature reading, flame current of pilot flame
sensor, current temperature setpoint, F°/C° display change, temperature
differential, software version, and error code history (up to ten previous error
codes).
Optional Air Intake Ducting—Optional ducting of PVC, CPVC, or ABS air
intake. Can either be installed as a traditional atmospheric product requiring
inside air for combustion or applications where outside air is preferred.
Premix Power Burner—A self compensating negative pressure system
automatically regulates fuel flow when a change in combustion air is detected.
This provides for optimum combustion and efficiency. Automatically adjusts for
altitudes up to 10,000 ft.
Direct Spark Ignition—For improved operational dependability and durability.
Integrated Exhaust System—New configuration and vent connector height
allow for easy replacement of existing atmospheric vent water heaters.
Sanitizing Capability—Complies with sanitation capabilities up to 180°F
(82°C).
Factory-Installed Hydrojet® Total Performance System—Sediment reducing
device that also increases first hour delivery of hot water while minimizing
temperature build-up in tank.
Vitraglas® Lining—An exclusively engineered enamel formula that provides
superior tank protection from the highly corrosive effects of hot water. This
formula (Vitraglas®) is fused to the steel surface by firing at a temperature of
over 1600°F (871°C).
Insulation System—Non-CFC foam covers the sides and top of the tank,
reducing heat loss. This results in less energy consumption, improved
efficiencies, and jacket rigidity.
Water Connections—Factory-installed true dielectric fittings extend water
heater life and simplify water line connections.
1" (25mm) NPT Side Connections for Space Heating.
Up to 82% Thermal Efficiency.
Zero Inch Clearance to Combustibles Excluding UCG-80H-399 &
UCG-100H-399.
Hand Hole Cleanout.
NSF Construction Available.
T&P Relief Valve—Installed.
Low Restrictive Brass Drain Valve—Durable tamper proof design.
Ultra Low NOx Construction (14 ng/J NOx emissions)—Natural gas models
only.
CSA Certified Low Lead Content.
ASME Code Available on All Models.
3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada. and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
Commander Series Atmospheric Vent
Commercial Gas Water Heater
Photo is of
UCG-100H-199-3N
FEATURING:
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526;
6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984;
8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS:
2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.
741-C-1217
©2017, Bradford White Corporation. All rights reserved.
Sales / Technical Support 866-690-0961 / 905-203-0600 l Fax 905-636-0666 / www.bradfordwhite.com
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 l Fax 215-641-1670 / Technical Support 800-334-3393 l Fax 269-795-1089 l Warranty 800-531-2111 l Fax 269-795-1089
International: Telephone 215-641-9400 l Telefax 215-641-9750 / www.bradfordwhite.com
Ambler, PA
Commander Series Atmospheric Vent Commercial Gas Water Heater
NATURAL GAS
Commander Series
Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model
Number
C
Floor to
Cold
Water
Inlet
in.
Approx.
Shipping
Weight
lbs.
G
Floor
to
Gas
Conn.
in.
A
Floor
to
Top of
Vent
in.
Input
Nat.
BTU/Hr.
Input
Capacity
U.S.
Gal.
E
Floor
to Hot
Water
Outlet
in.
B
Vent.
Dia.
in.
140°F100°F40°F
GPH Recovery
at Degree Rise*
UCG-80H-125-3N(A)
UCG-80H-199-3N(A)
UCG-80H-270-3N(A)
UCG-80H-399-3N(A)
UCG-100H-199-3N(A)
UCG-100H-270-3N(A)
UCG-100H-399-3N(A)
125,000
199,999
270,000
399,999
199,999
270,000
399,999
308
493
665
960
493
665
994
123
197
266
384
197
266
398
88
141
190
274
141
190
284
80
80
80
80
100
100
98
Imp.
Gal.
67
67
67
67
83
83
82
63
643/4
643/4
683/4
731/4
731/4
771/4
5
6
6
8
6
6
8
10
10
10
10
10
10
10
11/2
11/2
11/2
11/2
11/2
11/2
11/2
3/4
3/4
1
1
3/4
1
1
3/4
3/4
3/4
3/4
3/4
3/4
3/4
47
47
47
47
551/2
551/2
551/2
553/4
553/4
553/4
553/4
631/4
631/4
631/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4
30
30
30
30
30
30
30
44
44
44
44
521/2
521/2
521/2
611/4
611/4
611/4
611/4
69 3/4
69 3/4
69 3/4
D
Floor
to
T&P
Conn.
in.
F
Floor
to
Top of
Heater
in.
Gas
Conn.
Dia.
in.
Water
Conn.
Dia.
in.
Relief
Valve
Open
in.
Model
Number
C
Floor to
Cold
Water
Inlet
mm.
Approx.
Shipping
Weight
kgs.
G
Floor
to
Gas
Conn.
mm.
A
Floor
to
Top of
Vent
mm.
Input
Nat.
kW
Input
Capacity
Liters
E
Floor
to Hot
Water
Outlet
mm.
B
Vent.
Dia.
mm.
78°C56°C22°C
LPH Recovery
at Degree Rise*
UCG-80H-125-3N(A)
UCG-80H-199-3N(A)
UCG-80H-270-3N(A)
UCG-80H-399-3N(A)
UCG-100H-199-3N(A)
UCG-100H-270-3N(A)
UCG-100H-399-3N(A)
36.6
58.6
79.1
117.2
58.6
79.1
117.2
1164
1864
2517
3634
1866
2517
3757
466
746
1007
1454
745
1006
1476
333
533
719
1038
533
719
1060
303
303
303
303
379
379
371
1600
1645
1645
1746
1861
1861
1962
127
152
152
203
152
152
203
254
254
254
254
254
254
254
38
38
38
38
38
38
38
19
19
25
25
19
25
25
19
19
19
19
19
19
19
1194
1194
1194
1194
1410
1410
1410
K
Floor to
Cold Water
Inlet/Hot
Water Outlet
in.
543/4
543/4
543/4
543/4
631/4
631/4
631/4
K
Floor to
Cold Water
Inlet/Hot
Water Outlet
mm.
1391
1391
1391
1391
1607
1607
1607
1416
1416
1416
1416
1607
1607
1607
H
Depth
in.
H
Depth
mm.
762
762
762
762
762
762
762
J
Width
in.
11/2
11/2
11/2
11/2
11/2
11/2
11/2
3/4
3/4
3/4
3/4
3/4
3/4
1
391/2
391/2
391/2
391/2
391/2
421/2
431/2
J
Width
mm.
718
718
718
718
718
718
718
535
535
545
545
632
632
657
243
243
247
247
286
286
298
1118
1118
1118
1118
1334
1334
1334
1556
1556
1556
1556
1772
1772
1772
D
Floor
to
T&P
Conn.
mm.
F
Floor
to
Top of
Heater
mm.
Gas
Conn.
Dia.
mm.
Water
Conn.
Dia.
mm.
Relief
Valve
Open
mm.
Up to 82% Thermal Efficiency
For Propane Gas models change suffix “N” to “X”. Example: UCG-100H-199-3X (UCG-100H-399 available in Natural
Gas only). Natural gas models comply with the latest Ultra Low NOx requirements (14 ng/J or less).
Amp Draw range = 1.0 to 1.8 amps.
(A) ASME - All models are available with ASME construction.
To order ASME construction add the (A) to the end of the model number.
G
C
E
J
H
D
AF
K
B
Sample Specification
The water heater shall be a Bradford White model UCG-_____ with a rated storage capacity of not less than _____ gallons/ liters, a minimum gas input of __________ BTU/Hr., a minimum
recovery of _____ GPH/LPH at 100°F (56°C) temperature rise, a Thermal Efficiency Rating of _____. It shall be design certified by CSA International (formerly AGA and CGA) for 180°F (82°C)
application, either with or without a separate storage tank. The tank shall be lined with Vitraglas
®
vitreous enamel and shall have a bolted hand hole cleanout. This water heater shall be
equipped with stainless steel cold water inlet, Hydrojet
®
Sediment Reduction System. The heater shall be insulated with Non-CFC foam. This water heater shall be equipped with an ICON
HD
ignition system, an ASME rated T&P relief valve and a premix combustion system. The water heater shall be factory assembled and tested. A digital LCD display shall be integrated into
the front and be an adjustable electronic thermostat to any temperature up to 180°F. A recycling Energy Cut Off (E.C.O.) shuts off all gas in the event of an overheat condition. The entire
installation shall be made in compliance with state and local codes and ordinances.
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All models are design certified by CSA International (formerly AGA/CGA), to
ANSI standard Z-21.10.3, for up to 180°F (82°C) application as an Automatic Storage Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems.
It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it can supply 180°F (82°C) sanitizing and lower temperature general purpose
hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended).
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Model
Optional Air Intake Ducting Maximum Lengths
2"
PVC, ABS,
or CPVC
20 ft.
20 ft.
20 ft.
20 ft.
20 ft.
N/A
N/A
3"
PVC, ABS,
or CPVC
50 ft.
50 ft.
50 ft.
50 ft.
50 ft.
25 ft.
25 ft.
4"
PVC, ABS,
or CPVC
75 ft.
75 ft.
75 ft.
75 ft.
75 ft.
50 ft.
50 ft.
UCG-80H-125-3(N,X)
UCG-80H-199-3(N,X)
UCG-100H-199-3(N,X)
UCG-80H-270-3(N,X)
UCG-100H-270-3(N,X)
UCG-80H-399-3(N,X)
UCG-100H-399-3N
Printed in U.S.A.741-C-1217
Optional Power Vent Kits – for side wall
termination only.
Model Numbers Kit Number
UCG-80H-125/199/270,
UCG-100H-199/270: 239-81764-00
UCG-80H-399,
UCG-100H-399: 239-81766-00
Optional Honeywell EnviraCOM Alarm Module – Provides indication (contacts are
closed) when an alarm is present via normally open contacts (rated for up to 24 VAC).
Kit Number – 265-51961-00
TYPICAL APPLICATIONS
G
C
E
J
H
D
AF
K
B
Vent Kit