Bradfordwhite Piping Diagram Residential Gas With Integrated Mixing Device Honeywell Imd Two Water Heaters 30773_PD12 3 RG & RC User Manual
Piping Diagram Commercial Gas Light Duty With Integrated Mixing Device Honeywell Imd Two Water Heaters piping_diagram_commercial_gas_light_duty_with_integrated_mixing_device_honeywell_imd_two_water_heaters piping_diagram_commercial_gas_light_duty_with_integrated_mixing_device_honeywell_imd_two_water_heaters uploads wp-content bradfordwhitecorp :
2017-11-15
User Manual: Bradfordwhite Piping Diagram Residential Gas With Integrated Mixing Device Honeywell Imd Two Water Heaters piping_diagram_residential_gas_with_integrated_mixing_device_honeywell_imd_two_water_heaters uploads wp-content bradfordwhitecorp :
Open the PDF directly: View PDF
.
Page Count: 1

TWO RESIDENTIAL/LD
ATMOSPHERIC VENT
MODELS WITH
INTEGRATED
MIXING DEVICE
WATER SUPPLY
MIXED WATER
BACK-FLOW PREVENTER
SHUT OFF VALVE
EXPANSION TANK*
SHUT OFF VALVE
TEMPERATURE
AND PRESSURE
RELIEF VALVE
DISCHARGE TUBE
DRAIN
DRAIN OUTLET
DRAIN
DRAIN OUTLET
DISCHARGE TUBE
SHUT OFF
VALVE
UNION
HONEYWELL INTEGRATED
MIXING DEVICE (IMD)
UNION
SHUT OFF VALVE
UNION
SHUT OFF
VALVE
UNION
UNION
TEMPERATURE
AND PRESSURE
RELIEF VALVE
HONEYWELL INTEGRATED
MIXING DEVICE (IMD)
THIS DRAWING SHOWS A SUGGESTED PIPING
CONFIGURATION AND OTHER DEVICES; CHECK
WITH LOCAL CODES AND ORDINANCES FOR
ADDITIONAL REQUIREMENTS.
*EXPANSION TANK RECOMMENDED TO
MINIMIZE ANY PRESSURE BUILD UP IF THE
WATER SUPPLY PIPING HAS A BACK-FLOW
PREVENTER, CHECK VALVE OR WATER
METER WITH A CHECK VALVE.