EFFECTIVE DATE
FEBRUARY 11, 2019
At Bradford White, our business is being there for your business. Our job is to
help you serve the needs of contractors, installers and specifying engineers.
And that’s not just talk – we stand behind you every day.
When you sell Bradford White, you can always count on getting:
Built to be the BestTM
©2017, Bradford White Corporation. All rights reserved.
Built to be the BestTM
WE’RE HERE
FOR THE PRO.
And We Mean It.
Visit bwforthepro.com
to learn more!
Built to be the Best™ water
heaters, boilers and tanks that deliver
top quality, high performance and
unmatched reliability.
Unparalleled Tech Sales Support,
so you have all the resources you
need to make sure the needs of your
customers are met.
Marketing Materials to help you
communicate with your professional
customers and prospects more
e ectively than ever before.
Our Exclusive For The Pro®
Website – full of tools to help you
build your business and ensure your
success.
LEARN MORE ABOUT US AND OUR PRODUCTS AT BRADFORDWHITECORPORATION.COM/AMERICANSTRONG
American Pride has always been in everything we do. Bradford White began
over 135 years ago with a simple vision, to deliver high quality, superior products made by
American craftspeople.
We are committed to American manufacturing. We are an American-owned
company, with all our manufacturing facilities located in the United States. Bradford White
proudly employs over 1,500 people at our American facilities.
We proudly support the professional. At Bradford White, we focus on the
professional. Our quality product deserves a quality installation.
American Strong…around the world. Bradford White products are available
to professionals around the world. For example, our Halton Hills, ON sales, training and
distribution center provides full support to our Canadian customers.
Built to be the Best™. Bradford White proudly brings American ingenuity and quality
to customers around the world. By combining American Strong manufacturing with
select components and products sourced from top international partners, the result is all
Bradford White products are Built to be the Best
TM
- now and in the future.
What American Strong means to Bradford White.
At Bradford White, our business is being there for your business. Our job is to
help you serve the needs of contractors, installers and specifying engineers.
And that’s not just talk – we stand behind you every day.
When you sell Bradford White, you can always count on getting:
Built to be the BestTM
©2017, Bradford White Corporation. All rights reserved.
Built to be the BestTM
WE’RE HERE
FOR THE PRO.
And We Mean It.
Visit bwforthepro.com
to learn more!
Built to be the Best™ water
heaters, boilers and tanks that deliver
top quality, high performance and
unmatched reliability.
Unparalleled Tech Sales Support,
so you have all the resources you
need to make sure the needs of your
customers are met.
Marketing Materials to help you
communicate with your professional
customers and prospects more
eectively than ever before.
Our Exclusive For The Pro®
Website – full of tools to help you
build your business and ensure your
success.
for the pro ad 8.5x11_no_solar.indd 1 11/16/18 9:31 AM
3
Index
Terms of Sale ........................................................................................ 3
n General Information n Parts
n Freight Policy n Return Material Policy
Warranty Information ........................................................................... 4
New Model Number Naming Structure ............................................. 5
Commercial Gas Models
Light Duty Atmospheric Vent High Input Models .....................................7
Light Duty Commercial High Efficiency eF Series® Power Vent Model .....8
Light Duty Power Vent (TTW®) Models ...................................................... 8
Light Duty Power Direct Vent Models........................................................8
Light Duty Direct Vent Models ...................................................................9
Light Duty Ultra Low NOx Atmospheric Vent High Input Models ...........9
Light Duty Ultra Low NOx Direct Vent Models .......................................10
Light Duty Ultra Low NOx Power Vent (TTW®) Models .......................... 10
Light Duty Ultra Low NOx Power Direct Vent Models ...........................10
Commander Series™ Atmospheric Vent Models ....................................11
Electronic Ignition Models ........................................................................12
Induced Draft Models ...............................................................................13
Millivolt Models ..........................................................................................13
eF Series® Ultra High Efficiency Models ...........................................14-15
Commercial Electric Models
ElectriFLEX LD™ (Light Duty) Upright..............................................16-17
ElectriFLEX LD™ (Light Duty) Lowboy .............................................16-17
ElectriFLEX LD™ (Light Duty) Utility ...................................................... 18
ElectriFLEX LD™ (Light Duty) Wall Hung ............................................. 18
ElectriFLEX MD™ (Medium Duty) ......................................................... 19
ElectriFLEX HD™ (Heavy Duty) ........................................................20-22
ASME Models ..................................................................................23-24
Brute® Vertical Round ...................................................................... 25-28
Commercial Indirect-Fired
PowerStor Series™ Single-Wall Indirect Models ................................. 29
Commercial Storage Tank
Large Volume Storage Tank Models ............................................... 30-35
YELLOW SHADED AREAS INDICATE PRODUCTS INTRODUCED IN THIS PRICE SCHEDULE.
Any product not manufactured by Bradford White cannot be returned for credit.
BLUE SHADED HEADERS INDICATE PRODUCTS THAT ARE NET AND NOT SUBJECT TO PERFORMANCE INCENTIVE PROGRAM.
n GENERAL INFORMATION
1. This price schedule does not constitute an offer
to sell. All orders are subject to final approval and
acceptance. Prices, terms and specifications are
subject to change without notice. Billing prices are
those in effect on the date of order entry for immediate
shipment only.
2. All shipments are F.O.B. shipping point. Under such
F.O.B. terms, the beneficial and legal title to, ownership
of, right to possession of, control over and risk of loss
and damage to the goods shall pass to Customer at
the F.O.B. shipping point upon Seller’s tender of the
goods for delivery to Customer or a common carrier.
For purposes of this Agreement, delivery of the goods
includes tendering the goods to be loaded into the
transportation unit of the Customer or common carrier
located on Seller’s property.
3. Terms 2% 10th prox. Net 30th prox. origin.
4. All gas water heaters are design certified by CSA
International (formerly AGA and CGA) in accordance
with ANSI Z21.10.1 or 10.3 latest edition. Closed
combustion manufactured home heaters are listed by
Underwriters Laboratories.
5. All electric water heaters are listed by Underwriters
Laboratories and/or Intertek (ETL).
6. Please specify type of gas, element wattages, phase,
and voltages when ordering.
n PARTS
(Standard stock Shipments)
All parts orders under $500.00 net will be shipped
prepaid and charged F.O.B. shipping point. Parts
orders totaling $500.00 or more net will be shipped
F.F.A.
“Surface”. We reserve the right to ship by the carrier
of our choice.
Water heater replacement parts that are defective
will be replaced free of charge (exclusive of freight
charges) within 1 year of purchase. The return must be
accompanied by a receipt providing date of purchase
and statement of defect.
n FREIGHT POLICY
The following terms apply to shipment of orders
to one destination. Commercial heaters each have
a unit value of one. 150 or more units to one
destination qualify for a $3.00 per unit truckload
allowance.
Large Volume Storage Tanks are excluded from
this freight policy. These units are shipped prepaid
and charged F.O.B. shipping point. No freight
allowed.
1 to 3 units - Shipped prepaid, full freight allowed,
plus $75.00 per unit handling charge. The per unit
handling charge is for factory and rep warehouse
orders. This applies to both shipments and pick-ups.
4 or more units - Shipped prepaid, full freight allowed,
no handling charge.
COMBINED HEATER FREIGHT TERMS
Handling charge for commercial heaters is waived if
order is accompanied by a residential order of 50 or
more pieces shipping to the same destination.
Power Lift Gate Charge ...............$125.00
Special LTL Packaging Charge......$75.00 per unit
n RETURN MATERIAL POLICY
No merchandise may be returned for credit until
written authorization has been received from Bradford
White Corporation. When so returned (provided the
equipment is saleable, unused, no more than six
months old based on manufacturing date and in
original carton), it must be returned freight prepaid,
and will be subject to a minimum 15% re-stocking
charge. Custom built Commercial Electric product
cannot be returned for credit. All merchandise returned
without authorization will be refused and returned
to the customer with any incurred expenses being
charged back to the customer.
Terms of Sale
4
Warranty Information
Warranty Extension Commercial Products Only
Some states do not allow limitations on warranties. See copy of the Warranty included with the heater. *Heat Exchanger Only **10 year parts warranty on warranty upgrade kit
models only. †Heater Body Element Assembly.
Limited Tank
Warranty
Limited Tank
Warranty
Commercial Electric Models
ElectriFLEX LD™ (Light Duty) Upright ...................................................... 3 year 1 Year
ElectriFLEX LD™ (Light Duty) Lowboy ..................................................... 3 year 1 Year
ElectriFLEX LD™ (Light Duty) Utility ........................................................ 3 year 1 Year
ElectriFLEX LD™ (Light Duty) Wall Hung ................................................. 3 year 1 Year
ElectriFLEX MD™ (Medium Duty) ............................................................ 3 year 1 Year
ElectriFLEX HD™ (Heavy Duty) ................................................................ 3 year 1 Year
Surface Mounted & Immersion Thermostat (Heavy Duty) Models .......... 3 year 1 Year
ASME Models ......................................................................................... 3 year 1 Year
Brute™ Vertical Round ............................................................................ 3 year 1 Year
Commercial Indirect-Fired
PowerStor Series® Single-Wall Indirect Models ..................................... 3 year 1 Year
Commercial Storage Tank
M3ST Models (80,120,200).................................................................... 5 year 1 Year
Custom Models .............................................................. Varies by tank lining 1 Year
Commercial Gas Models
Light Duty Atmospheric Vent High Input Models .................................... 3 year 1 Year
Light Duty Power Vent (TTW®) Models ................................................... 3 year 1 Year
Light Duty Power Direct Vent Models ..................................................... 3 year 1 Year
Light Duty Direct Vent Models ................................................................ 3 year 1 Year
Light Duty Ultra Low NOx Atmospheric Vent High Input Models ............. 3 year 1 Year
Light Duty Ultra Low NOx Direct Vent Models ........................................ 3 year 1 Year
Light Duty Commercial High Efficiency eF Series® Power Vent Model ... 3 year 1 Year
Light Duty Ultra Low NOx Power Vent (TTW®) Models ........................... 3 year 1 Year
Light Duty Ultra Low NOx Power Direct Vent Models ............................. 3 year 1 Year
Commander Series™ Atmospheric Vent Models ..................................... 3 year 1 Year
Electronic Ignition Models ...................................................................... 3 year 1 Year
Induced Draft Models ............................................................................. 3 year 1 Year
Millivolt Models ...................................................................................... 3 year 1 Year
eF Series® Ultra High Efficiency Models ................................................. 3 year 1 Year
Limited Parts
Warranty
Limited Parts
Warranty
Warranty Options
ASME Electric
6A .................... $255.00
12A ................... $255.00
20A ................... $255.00
30A ................... $434.00
40A ................... $434.00
50A ................... $434.00
80A ................... $829.00
120A .................. $829.00
Commander Series™
UCG-80H-125-3(N,X)* .... $342.00
UCG-80H-125-3(N,X)A* ... $464.00
UCG-80H-199-3(N,X)* .... $447.00
UCG-80H-199-3(N,X)A* ... $536.00
UCG-80H-270-3(N,X)* .... $562.00
UCG-80H-270-3(N,X)A* ... $613.00
UCG-80H-399-3(N,X)* .... $783.00
UCG-80H-399-3(N,X)A* ... $839.00
UCG-100H-199-3(N,X)* ... $447.00
UCG-100H-199-3(N,X)A* .. $567.00
UCG-100H-270-3(N,X)* ... $509.00
UCG-100H-270-3(N,X)A* .. $598.00
UCG-100H-399-3N ....... $733.00
UCG-100H-399-3NA ...... $773.00
HD Immersion Electrics
CEHD50 ................ $365.00
CEHD50A ............... $393.00
CEHD80 ................ $365.00
CEHD80A ............... $393.00
CEHD120 ............... $365.00
CEHD120A .............. $393.00
Light Duty Electric
LE16U3 ................ $113.00
LE110U3 ............... $113.00
LE112T3 ............... $113.00
LE115U3 ............... $113.00
LE120L3 ............... $113.00
LE120U3 ............... $113.00
LE130L3 ............... $113.00
LE140L3 ............... $113.00
LE150L3 ............... $113.00
LE230S3 ............... $126.00
LE240S3 ............... $126.00
LE250S3 ............... $126.00
LE265T3 ............... $126.00
LE280T3 ............... $126.00
LE2120T3 .............. $126.00
eF Series®
EF60T125E3(N,X)* ....... $315.00
EF60T125E3(N,X)A* ...... $404.00
EF60T150E3(N,X)* ....... $448.00
EF60T150E3(N,X)A* ...... $557.00
EF60T199E3(N,X)* ....... $515.00
EF60T199E3(N,X)A* ...... $630.00
EF100T150E3(N,X)* ...... $428.00
EF100T150E3(N,X)A* ..... $527.00
EF100T199E3(N,X)* ...... $439.00
EF100T199E3(N,X)A* ..... $538.00
EF100T250E3(N,X)* ...... $497.00
EF100T250E3(N,X)A* ..... $591.00
EF100T300E3(N,X)* ...... $567.00
EF100T300E3(N,X)A* ..... $667.00
EF120T4003(N)* ......... $618.00
EF120T4003(N)A* ........ $715.00
EF120T5003(N)* ......... $713.00
EF120T5003(N)A* ........ $784.00
Ultra Low Nox Light Duty Gas
ULG250H553N .......... $139.00
ULG275H763N .......... $169.00
ULG2100H853N ......... $199.00
ULG2DV50H453N-FLX .... $217.00
ULG2DV50H453N-OLY .... $217.00
ULG2DV50H453N-SLD .... $217.00
ULG2PDV50H503N ....... $219.00
ULG2PV50H563N ........ $239.00
ULG2PV75H763N ........ $202.00
Light Duty Gas
LC2PV50H763(N,X)* ..... $278.00
LG1PV55H783(N,X)* ..... $228.00
LG2PV50H653(N,X)* ..... $206.00
LG2PV75H763(N,X)* ..... $169.00
LG250H653(N,X)* ........ $103.00
LG255H803(N,X)* ........ $103.00
LG275H763(N,X)* ........ $147.00
LG2100H853(N,X)* ....... $182.00
LG2DV50H503(N,X)*-FLX .. $184.00
LG2DV50H503(N,X)*-OLY .. $184.00
LG2DV50H503(N,X)*-SLD .. $184.00
LG2PDV50H603(N,X)* .... $197.00
LG2PDV75H803(N,X)* .... $197.00
Medium Duty Electrics
E32-50S3-3 ............. $283.00
E32-80R3-3 ............. $283.00
E32-120R3-3 ............ $283.00
LE16WV3 ............... $113.00
LE112WV3 .............. $113.00
LE120WV3 .............. $113.00
D-Series
D-38T-155-3(N,X)* ....... $354.00
D-65T-370-3(N,X)* ....... $491.00
D-65T-370-3(N,X)A* ...... $580.00
D-65T-399-3N ........... $613.00
D-65T-399-3NA .......... $704.00
D-65T-625-3(N,X)* ....... $809.00
D-65T-625-3(N,X)A* ...... $829.00
D-75T-125-3(N,X)* ....... $278.00
D-75T-160-3(N,X)* ....... $354.00
D-75T-300-3(N,X)* ....... $437.00
D-75T-300-3(N,X)A* ...... $525.00
D-80L-399-3(N,X)* ....... $613.00
D-80L-399-3(N,X)A* ...... $704.00
D-80L-450-3(N,X)* ....... $690.00
D-80L-450-3(N,X)A* ...... $766.00
D-80L-505-3(N,X)* ....... $690.00
D-80L-505-3(N,X)A* ...... $766.00
D-80T-180-3(N,X)* ....... $365.00
D-80T-199-3(N,X)* ....... $367.00
D-80T-250-3(N,X)* ....... $392.00
D-80T-250-3(N,X)A* ...... $483.00
D-80T-425-3(N,X)* ....... $467.00
D-80T-425-3(N,X)A* ...... $525.00
D-80T-505-3(N,X)* ....... $467.00
D-80T-505-3(N,X)A* ...... $525.00
D-80T-725-3(N,X)* ....... $822.00
D-80T-725-3(N,X)A* ...... $853.00
D-100L-199-3(N,X)* ...... $375.00
D-100L-250-3(N,X)* ...... $416.00
D-100L-250-3(N,X)A* ..... $508.00
D-100L-270-3N .......... $428.00
D-100L-270-3NA ......... $522.00
D-100L-300-3(N,X)* ...... $437.00
D-100L-300-3(N,X)A* ..... $525.00
D-100S-199-3(N,X)* ...... $375.00
D-100S-250-3(N,X)* ...... $416.00
D-100S-250-3(N,X)A* ..... $508.00
D-100T-199-3(N,X)* ...... $375.00
D-100T-250-3(N,X)* ...... $416.00
D-100T-250-3(N,X)A* ..... $508.00
DM-80T-199-3N ......... $387.00
DM-100T-199-3N ........ $398.00
n * “N” = Natural Gas, “X” = Propane, A =ASME
n Extends standard three year tank warranty to five year
n Parts warranty remains at one year when upgrading to five year
tank warranty
n To ship five year warranty product from plant, in lieu of upgrading
to five year product, use invoice cost for three year warranty
product plus warranty increase upgrade cost1
n Use CEHD equivalent gallon product to upgrade MII products
Change the 3 to a 5
Examples:
EF100T199E3N to EF100T199E5N
D-75T-125-3N to D-75T-125-5N
Effective July 2, 2018 (rev 021419). U.S. Sales Only
How to change model number when ordering five year warranty product1
5
L G 2 H50 65 3 N
Application
L=Light Duty Commercial
C=Commercial
Capacity
Gallons
Input
MBTU/Hr.
Warranty
Years
Insulation Thickness
1=1"
2=2"
3=3"
Fuel
G=Gas
E=Electric
C=Condensing
Fuel Type
N=Natural
X=LP Gas
Tank Style
L=Lowboy
H=Hydronic Space Heating
U=Utility
WV=Wall Hung Vertical
NOTE: Indicators in “Vent Type” may not be present in all model numbers.
Combustion Process
U=Natural Gas Ultra Low NOx
Vent Type
None=Atmospheric
PV=Power Vent
PDV=Power Direct Vent
DV=Direct Vent
Model Number Naming Structure
Light Duty Commercial Model Number Structure
Our contractor directory has been updated and improved to add valuable new features -
and we want your professional customers to be on it! Encourage your contractor customers
to put their business listing on the Bradford White FIND A PRO directory today and they’ll:
Get Great New Features
Expanded profiles, customer reviews, ability to upload project photos, list certifications,
industry associations and more.
Attract More Customers
New expanded profile will help contractors stand out more and promote their business.
Grow Their and Your Business
Local customers will be connected directly with contractors, delivering new sales
opportunities for them and you.
Close New Leads FAST
Contractors get notified instantly about new
customer leads so they can lock-up jobs quickly.
Takes just 5 minutes to register –
it’s fast, easy and FREE!
©2017, Bradford White Corporation. All rights reserved.
Built to be the BestTM
Built to be the BestTM
bradfordwhite.com
© 2018 Bradford White Corporation.
All rights reserved.
Bradford White FIND A PRO Contractor Directory
HELP HOMEOWNERS FIND
YOUR PRO CUSTOMERS!
NEW
Visit bwfindapro.com
7
Commercial Gas Models
Commercial Gas Models
All Models meet or exceed both the Recovery Efficiency and Standby Loss Requirements of ASHRAE 90.1b (current standard) and are
listed with the California Energy Commission (CEC).
Model numbers shown are for Natural Gas. For LP Gas (Propane) change the suffix “N” to “X” and add $40.00 to Natural Gas net prices.
EX: LG250H653N becomes LG250H653X.
Some LP Gas inputs and recoveries vary from their Natural Gas counterparts. Consult current specification sheets for accurate information.
Because some states require that heaters 200,000 BTU/Hr. and over, or 120 gallons of storage and over, to be ASME constructed, check with
local codes and authorities for applicability.
All Commercial Gas models are designed certified by CSA International (formerly AGA and CGA).
COMMERCIAL
WATER HEATERS
TO MEET ANY
INDUSTRY NEED
High Performance Models
Light Duty Commercial Atmospheric Vent High Input Models
Non-CFC Foam Insulation
LG250H653N
LG255H783N
LG275H763N
LG2100H803N
63
78
74
82
Standard
Standard
Standard
Standard
4"
4"
4"
4"
193
207
263
424
22"
24"
26"
281/4"
601/2"
581/2"
625/8"
701/16"
50"
591/4"
63"
633/4"
65,000
78,000
76,000
80,000
48
55
75
100
46
55
72
95
106
117
135
157
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F
Rise
First
Hour
Rating
(Gal.) Style
Floor
to
Flue
Conn.
Jacket
Dia.
Vent
Size
Approx.
Shpg.
Wt.
Limited
3 Year
Tank Warranty
Price
DOE
Rated
Storage
Volume
(Gal.)
T&P Valve installed.
Temperature adjustment up to 180°F.
All models feature side connections for space heating and two anode rods.
*When tested to the industry standard Residential First Hour Delivery procedure.
Temperature adjustment up to 180°F.
NSF compliance kits available for all models.
Circulating Loop Installation Kit:
P/N 265-43103-00 (Dielectric unions, Isolation valves and Extended nipples) . . . $68.25
Water Connection Centers as Follows:
LG250H653N = 11"
LG255H783N = 8"
LG275H763N = 11"
LG2100H803N = 16"
Water Connection Sizes as Follows:
LG250H653N = 3⁄4"
LG255H783N = 3⁄4"
LG275H763N = 1"
LG2100H803N = 11/4"
Hand Hole cleanout standard on 100 gallon model only.
$2,150.00
2,300.00
3,070.00
3,810.00
8
Commercial Gas Models
Commercial Gas Models
Power Vent, Power Direct Vent Models
T&P Relief Valve Installed.
All models feature side connections for space heating.
NSF compliance kits available for all models.
Temperature adjustments up to 180ºF.
LG2PDV50H603N
LG2PDV75H803N
58
77
Standard
Standard
3"or 4"
3"or 4"
205
392
22"
26"
675/16"
6711/16"
50"
591/4"
63"
633/4"
60,000
80,000
48
75
46
72
103
134
Light Duty Commercial Power Direct Vent Models
2" Non-CFC Foam Insulation - 120 VAC required
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F
Rise
First
Hour
Rating
(Gal.) Style
Floor
to
Exhaust
Conn.
Jacket
Dia.
Vent
Size
Approx.
Shpg.
Wt.
Limited
3 Year
Tank Warranty
Price
DOE
Rated
Storage
Volume
(Gal.)
n 3" Concentric Vent Kit Termination P/N 239-44069-01 .........
$67.20
n Air Intake Relief Device P/N 239-48392-00 .........
$70.35
T&P Relief Valve Installed
. LG1PV55H783N Includes Mixing Valve.
All models feature side connections for space heating.
NSF compliance kits available for all models
Temperature adjustments up to 180ºF.
LG2PV50H653N
LG1PV55H783N
LG2PV75H763N
63
76
74
Standard
Standard
Standard
3"or 4"
3"or 4"
3"or 4"
186
253
252
22"
22"
26"
643/4"
643/8"
6711/16"
50"
591/4"
63"
633/4"
65,000
78,000
76,000
48
55
75
46
55
72
116
125
121
Light Duty Commercial TTW
® Power Vent Models
2" Non-CFC Foam Insulation - 120 VAC required
(LG1PV55H783N has 1" Non-CFC Foam Insulation)
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F
Rise
First
Hour
Rating
(Gal.) Style
Floor
to
Vent
Conn.
Jacket
Dia.
Vent
Size
Approx.
Shpg.
Wt.
Limited
3 Year
Tank Warranty
Price
DOE
Rated
Storage
Volume
(Gal.)
Light Duty Commercial High Efficiency eF Series
® Power Vent Model
2" Non-CFC Foam Insulation — 120 VAC required
LC2PV50H763N 83 Standard 2", 3"or 4" 22524"6731/74"
50"
591/4"
63"
633/4"
76,00050 49 120
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH
Rec.
100°F
Rise
First
Hour
Rating
(Gal.) Style
Floor
to
Vent
Conn.
Jacket
Dia.
Vent
Size
Approx.
Shpg.
Wt.
Limited
3 Year
Tank Warranty
Price
DOE
Rated
Storage
Volume
(Gal.)
$3,300.00
4,154.00
3,505.00
$3,085.00
$2,910.00
4,104.00
T&P Relief Valve Installed.
Feature side connections for space heating.
9
Commercial Gas Models
Commercial Gas Models
Direct Vent Models
Ultra Low NOx Models
LG2DV50H503N-SLD
LG2DV50H503N-FLX
LG2DV50H503N-OLY
47
47
47
Standard
Standard
Standard
4"
4"
4"
6"
6"
6"
217
217
217
22"
22"
22"
7511/16"
7511/16"
7511/16"
50"
591/4"
63"
633/4"
50,000
50,000
50,000
48
48
48
46
46
46
96
96
96
Light Duty Commercial Direct Vent Models
2" Non-CFC Foam Insulation
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F
Rise
First
Hour
Rating
(Gal.) Style
Floor to
C/L
of Vent
Conn.
(min.)
Jacket
Dia.
Vent
Size
I.D. O.D.
Approx.
Shpg.
Wt.
Limited
3 Year
Tank Warranty
Price
DOE
Rated
Storage
Volume
(Gal.)
Telescoping Solid Vent Kit (-SLD), or Flexible Vent Kit (-FLX) is shipped with the water heater.
Ex: LG2DV50H503N-SLD. This model ships with Telescoping Solid Vent Kit
Ex: LG2DV50H503N-FLX. This model ships with Flexible Vent Kit
When a Vent Kit is not needed or is required to be shipped separately add (-OLY) to the model number.
EX: LG2DV50H503N-OLY. This model ships without a Vent Kit.
Solid Vent Kit shipped separately. P/N 239-51286-00 ............
Flexible Vent Kit shipped separately. P/N 239-51287-00 ............
Refer to Installation and Operating Manual for Vent Kit Components. Horizontal vent termination only.
Optional Telescoping Solid Vent Kits:
n Kit “F” Telescopes from 43⁄4" to 511⁄16" P/N 239-42516-00 ............
n Kit “G” Telescopes from 61⁄2" to 93⁄16" P/N 239-42517-00 ............
n Kit “H” Telescopes from 133⁄4" to 2311⁄16" P/N 239-42514-00 ............
n Kit “I” Telescopes from 4913⁄16" to 9513⁄16" P/N 239-42512-00 ............
T&P Relief Valve Installed
.
All models feature side connections for space heating.
NSF compliance kits available for all models. Water connections are 3/4" on 11" centers.
Temperature adjustments up to 180ºF.
$2,905.00
3,010.00
2,850.00
$136.00
$172.00
$47.25
$59.85
$73.50
$129.15
ULG250H553N
ULG275H763N
ULG2100H803N
53
74
82
Standard
Standard
Standard
4"
4"
4"
193
263
424
22"
26"
281/4"
601/2"
643/4"
725/16"
50"
591/4"
63"
633/4"
55,000
76,000
80,000
48
75
100
46
72
95
110
135
157
Light Duty Commercial Ultra Low NOx Atmospheric Vent High Input Models
2" Non-CFC Foam Insulation
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F
Rise
First
Hour
Rating
(Gal.) Style
Floor
to
Flue
Conn.
Jacket
Dia.
Vent
Size
Approx.
Shpg.
Wt.
Limited
3 Year
Tank Warranty
Price
DOE
Rated
Storage
Volume
(Gal.)
T&P Relief Valve Installed.
All models feature side connections for space heating.
NSF compliance kits available for all models.
Temperature adjustments up to 180ºF.
$3,421.00
3,510.00
4,104.00
10
Commercial Gas Models
Commercial Gas Models
T&P Relief Valve Installed
. All models feature side connections for space heating.
NSF compliance kits available for all models. Water connections are 3/4" on 11" centers. Temperature adjustments up to 180ºF.
Telescoping Solid Vent Kit (-SLD), or Flexible Vent Kit (-FLX) is shipped with the water heater.
Ex: ULG2DV50H453N-SLD. This model ships with Telescoping Solid Vent Kit
Ex: ULG2DV50H453N-FLX. This model ships with Flexible Vent Kit
When a Vent Kit is not needed or is required to be shipped separately add (-OLY) to the model number.
EX: ULG2DV50H453N-OLY. This model ships without a Vent Kit.
Solid Vent Kit shipped separately. P/N 239-51286-00 .................
Flexible Vent Kit shipped separately. P/N 239-51287-00 .................
Refer to Installation and Operating Manual for Vent Kit Components. Horizontal vent termination only.
Optional Telescoping Solid Vent Kits:
n Kit “F” Telescopes from 43⁄4" to 511⁄16" P/N 239-42516-00 .................
n Kit “G” Telescopes from 61⁄2" to 93⁄16" P/N 239-42517-00 .................
n Kit “H” Telescopes from 133⁄4" to 2311⁄16" P/N 239-42514-00 .................
n Kit “I” Telescopes from 4913⁄16" to 9513⁄16" P/N 239-42512-00 .................
T&P Relief Valve Installed. All models feature side connections for space heating.
NSF compliance kits available for all models.
Temperature adjustments up to 180ºF.
ULG2PV50H563N
ULG2PV75H763N
54
74
Standard
Standard
3"or 4"
3"or 4"
190
270
22"
26"
643/4"
6711/16"
50"
591/4"
63"
633/4"
56,000
76,000
48
75
46
72
107
121
Light Duty Commercial Ultra Low NOx TTW® Power Vent Models
2" Non-CFC Foam Insulation - 120 VAC required
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F
Rise
First
Hour
Rating
(Gal.) Style
Floor
to
Vent
Conn.
Jacket
Dia.
Vent
Size
Approx.
Shpg.
Wt.
Limited
3 Year
Tank Warranty
Price
DOE
Rated
Storage
Volume
(Gal.)
*
$3,597.00
5,124.00
ULG2DV50H453N-SLD
ULG2DV50H453N-FLX
ULG2DV50H453N-OLY
43
43
43
Standard
Standard
Standard
4"
4"
4"
6"
6"
6"
201
201
201
22"
22"
22"
755/16"
755/16"
755/16"
50"
591/4"
63"
633/4"
45,000
45,000
45,000
48
48
48
46
46
46
83
83
83
Light Duty Commercial Ultra Low NOx Direct Vent Models
1" Non-CFC Foam Insulation
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F
Rise
First
Hour
Rating
(Gal.) Style
Floor to
C/L
of Vent
Conn.
(min.)
Jacket
Dia.
Vent
Size
I.D. O.D.
Approx.
Shpg.
Wt.
Limited
3 Year
Tank Warranty
Price
DOE
Rated
Storage
Volume
(Gal.)
Light Duty Commercial Gas Product Options Add
n NSF Compliance Kit: (All models except (U)LG100H
P/N 243-41203-00 ........................................................................................................
n NSF Compliance Kit: (U)LG2100H Only
P/N 243-41209-00 ........................................................................................................
n For LP gas (propane) change suffix “N” to “X” and add ..........................................
to natural gas net prices where applicable.
n Circulating Loop Installation Kit:
P/N 265-43103-00 (Dielectric unions, Isolation valves and Extended nipples)...........
The NSF kit for Light Duty Commercial Gas water heaters is ordered as a separate line item with the water heater using the
applicable part number. The kits are also available for order through our parts department for field conversions.
ULG2PDV50H503N 48 Tall 3"or 4" 20122"675/16"
50"
591/4"
63"
633/4"
50,00048 46 82
Light Duty Ultra Low NOx Power Direct Vent Models
2" Non-CFC Foam Insulation - 120 VAC required
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F
Rise
First
Hour
Rating
(Gal.) Style
Floor
to
Vent
Conn.
Jacket
Dia.
Vent
Size
Approx.
Shpg.
Wt.
Limited
3 Year
Tank Warranty
Price
DOE
Rated
Storage
Volume
(Gal.)
T&P Relief Valve Installed
. Feature side connections for space heating. NSF compliance kits available for all models.
Water connections are 3/4" on 11" centers.
Temperature adjustments up to 180ºF.
n 3" Concentric Vent Kit Termination P/N 239-44069-01 ........
n Air Intake Relief Device P/N 239-48392-00 ........
$3,902.00
$67.20
$70.35
$76.65
$76.65
$40.00
$68.25
$3,268.00
3,359.00
3,178.00
$136.00
$172.00
$47.25
$59.85
$73.50
$129.15
11
Commercial Gas Models
Commercial Gas Models
COMMANDER
SERIES
™
COMMERCIAL GAS WATER HEATER,
WITH ITS SMALL FOOTPRINT, LIGHT
WEIGHT, AND SHORTER HEIGHT,
FITS JUST ABOUT
ANYWHERE.
Heavy Duty Atmospheric Vent Models
Commander Series Atmospheric Vent Models — Non-ASME
Non-CFC Foam Insulation - 120 VAC Required
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise Style Floor to
Flue Conn.
Jacket
Dia.
Vent
Size
Approx.
Shpg. Wt.
UCG-80H-125-3N
UCG-80H-199-3N
UCG-80H-270-3N
UCG-80H-399-3N
UCG-100H-199-3N
UCG-100H-270-3N
UCG-100H-399-3N
123
197
266
384
197
266
398
Standard
Standard
Standard
Standard
Standard
Standard
Standard
5"
6"
6"
8"
6"
6"
8"
535
535
545
545
632
632
657
28"
28"
28"
28"
28"
28"
28"
6815/16"
6213/16"
6213/16"
6815/16"
731/4"
731/4"
777/16"
50"
591/4"
63"
633/4"
125,000
199,999
270,000
399,999
199,999
270,000
399,999
80
80
80
80
100
100
98
Limited 3 Year
Tank Warranty Price
TM
Commander Series Atmospheric Vent Models — ASME
Non-CFC Foam Insulation - 120 VAC Required
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise Style Floor to
Flue Conn.
Jacket
Dia.
Vent
Size
Approx.
Shpg. Wt.
UCG-80H-125-3NA
UCG-80H-199-3NA
UCG-80H-270-3NA
UCG-80H-399-3NA
UCG-100H-199-3NA
UCG-100H-270-3NA
UCG-100H-399-3NA
123
197
266
384
197
266
398
Standard
Standard
Standard
Standard
Standard
Standard
Standard
5"
6"
6"
8"
6"
6"
8"
535
535
545
545
632
632
657
28"
28"
28"
28"
28"
28"
28"
6815/16"
6213/16"
6213/16"
6815/16"
731/4"
731/4"
777/16"
50"
591/4"
63"
633/4"
125,000
199,999
270,000
399,999
199,999
270,000
399,999
80
80
80
80
100
100
98
Limited 3 Year
Tank Warranty Price
TM
Product Options
n For propane gas models change suffix “N” to “X” (Propane Gas not available on UCG-100H-399-3N)
Example: UCG-100H-199-3X, and add .........................................................................................................................
to natural gas net prices where applicable.
T&P Relief Valve Installed.
NSF compliance kits available for all models.
$7,165.00
9,370.00
10,750.00
15,390.00
9,370.00
10,685.00
16,425.00
$10,015.00
11,569.00
14,050.00
17,650.00
11,910.00
13,250.00
18,830.00
$40.00
12
Commercial Gas Models
Commercial Gas Models
Flue Damper and Induced Draft Models
Low NOx Models: For Low NOx models add “E” to the model number as displayed, EX: D-100T-199E-3N
and increase net price by: ...................................................................
The Low NOx option is available on Natural Gas Models ONLY, with inputs from 125,000 to 399,999.
T&P Relief Valve Installed and Hand Hole Cleanout is standard.
Electronic Ignition Models — Non-ASME
Non-CFC Foam Insulation - 120 VAC required
†† Available in Natural Gas only.
Electronic Ignition Models — ASME
Non-CFC Foam Insulation - 120 VAC required
†† Available in Natural Gas only.
$175.00
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise
Floor to
Top of
Heater
Dia. Vent
Size
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
Price
D-38T-155-3N 38 155,000 150 471⁄16"281⁄4" 6" 438 $7,885.00
D-65T-370-3N 65 370,000 359 685⁄16" 281⁄4" 8" 665
10,990.00
D-65T-399-3N†† 65 399,999 388 685⁄16" 281⁄4" 8" 665
13,055.00
D-75T-125-3N 75 125,000 121 691⁄16" 281⁄4" 5" 520
5,880.00
D-75T-160-3N 75 160,000 155 691⁄16" 281⁄4" 6" 520
7,345.00
D-75T-300-3N 75 300,000 291 6913⁄16" 281⁄4" 7" 590
9,135.00
D-80T-180-3N 80 180,000 175 685⁄16" 281⁄4" 6" 540
7,600.00
D-80T-199-3N 80 199,999 194 685⁄16" 281⁄4" 6" 540
7,600.00
D-80T-250-3N 80 250,000 242 685⁄16" 281⁄4" 6" 540
8,100.00
D-80L-399-3N 80 399,999 388 641⁄4" 301⁄4" 8" 800
10,345.00
D-80L-450-3N 80 450,000 436 641⁄4" 301⁄4" 10" 800
14,475.00
D-80T-425-3N 80 425,000 412 795⁄16" 281⁄4" 10" 750
14,680.00
D-80L-505-3N 80 505,000 489 641⁄4" 301⁄4" 10" 800
14,510.00
D-80T-505-3N 80 505,000 489 795⁄16" 281⁄4" 10" 750
14,510.00
D-100L-199-3N 100 199,999 194 6815⁄16" 301⁄4" 6" 725
7,825.00
D-100S-199-3N 100 199,999 194 795⁄16" 281⁄4" 6" 667
7,825.00
D-100T-199-3N 98 199,999 194 795⁄16" 281⁄4" 6" 610
7,825.00
D-100L-250-3N 100 250,000 242 685⁄16" 301⁄4" 6" 725
8,705.00
D-100S-250-3N 100 250,000 242 795⁄16 281⁄4" 6" 667
8,705.00
D-100T-250-3N 98 250,000 242 795⁄16" 281⁄4" 6" 610
8,705.00
D-100L-270-3N†† 100 270,000 262 685⁄16" 301⁄4" 6" 725
8,980.00
D-100L-300-3N 100 300,000 291 685⁄16" 301⁄4" 7" 725
9,200.00
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise
Floor to
Top of
Heater
Dia. Vent
Size
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
Price
D-65T-370-3NA 65 370,000 359 685⁄16" 281⁄4" 8" 720
$12,755.00
D-65T-399-3NA†† 65 399,999 388 685⁄16" 281⁄4" 8" 720
13,485.00
D-75T-300-3NA 75 300,000 291 6913⁄16" 281⁄4" 7" 645
11,010.00
D-80T-250-3NA 80 250,000 242 685⁄16" 281⁄4" 6" 590
10,045.00
D-80L-399-3NA 80 399,999 388 641⁄4" 301⁄4" 8" 835
12,160.00
D-80L-450-3NA 80 450,000 436 641⁄4" 301⁄4" 10" 835
15,930.00
D-80T-425-3NA 80 425,000 412 795⁄16" 281⁄4" 10" 800
15,985.00
D-80L-505-3NA 80 505,000 489 641⁄4" 301⁄4" 10" 835
15,995.00
D-80T-505-3NA 80 505,000 489 795⁄16" 281⁄4" 10" 800
15,995.00
D-100L-250-3NA 100 250,000 242 685⁄16" 301⁄4" 6" 765
10,690.00
D-100S-250-3NA 100 250,000 242 795⁄16" 281⁄4" 6" 702
10,690.00
D-100T-250-3NA 98 250,000 242 795⁄16" 281⁄4" 6" 690
10,690.00
D-100L-270-3NA†† 100 270,000 262 685⁄16" 301⁄4" 6" 765
10,885.00
D-100L-300-3NA 100 300,000 291 685⁄16" 301⁄4" 7" 765
10,995.00
13
Commercial Gas Models
Commercial Gas Models
Induced Draft Models — ASME
Non-CFC Foam Insulation - 120 VAC required
Product Options
n Power Vent Kits Available for Electronic Ignition models ONLY with inputs from 125,000 to 505,000 BTU’s/Hr.
125,000 - 270,000 BTU/Hr. P/N 239-81764-00 ............................................
300,000 - 399,999 BTU/Hr. P/N 239-81766-00 ............................................
400,000 - 505,000 BTU/Hr. P/N 239-82148-00 ............................................
n NSF Compliance Kits: P/N 265-44541-01 (D-Series T and S Models) ...........................
P/N 265-44541-02 (D-Series L Models) .................................
Induced Draft Models — Non-ASME
Non-CFC Foam Insulation - 120 VAC required
$635.25
$752.85
$843.15
$76.65
$76.65
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise
Floor to
Top of
Heater
Dia. Vent
Size
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
Price
D-65T-625-3N 65 625,000 606 733⁄8"281⁄4" 8" 720 $15,040.00
D-80T-725-3N 80 725,000 703 8315⁄16" 281⁄4" 8" 800 15,770.00
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise
Floor to
Top of
Heater
Dia. Vent
Size
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
Price
D-65T-625-3NA 65 625,000 606 733⁄8"281⁄4" 8" 775 $16,045.00
D-80T-725-3NA 80 725,000 703 8315⁄16" 281⁄4" 8" 880 16,805.00
Product Options
n NSF Compliance Kits:
P/N 265-44541-05 DM-Series T and S Models .............................................
P/N 265-44541-06 DM-Series L Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
n Low NOx Models: For Low NOx models add “E” to the model number as displayed, EX: DM-100T-199E-3N
and increase net price by: ..................................................................
The Low NOx option is available on Natural Gas Models ONLY, with inputs from 125,000 to 270,000.
T&P Relief Valve Installed and Hand Hole Cleanout is standard.
Millivolt Models — Non-ASME
Non-CFC Foam Insulation - No electricity required
$175.00
$76.65
$76.65
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise
Floor to
Top of
Heater
Dia. Vent
Size
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
Price
DM-80T-199-3N 80 199,999 194 763⁄8" 281⁄4" 6" 540
$8,025.00
DM-100T-199-3N 98 199,999 194 8815⁄16" 281⁄4" 6" 610
8,236.00
Millivolt Models
14
Commercial Gas Models
Commercial Gas Models
ENERGY-SAVING
PERFORMANCE FOR
THE MOST DEMANDING
APPLICATIONS.
ULTRA HIGH
EFFICIENCY
WATER HEATERS
Ultra High Efficiency Models — Non-ASME
Non-CFC Foam Insulation - 120 VAC required
Product Options
n Direct Spark Ignition Conversion Kit: P/N 265-48866-01 (125,000 - 199,000 BTU/Hr.) ............
P/N 265-48866-02 (250,000 & 300,000 BTU/Hr.) ............
n 2" Concentric Vent Kit Termination: P/N 239-44069-02 .....................................
n 3" Concentric Vent Kit Termination: P/N 239-44069-01 .....................................
n NSF Compliance Kit: P/N 265-44542-04. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
n Maxitrol Pressure Regulator:
For separate part order 243-45517-00 ......................................................
n Low Inlet Gas Pressure (3.5" w.c.):
For eF heater (except EF-100T-300) with Low Inlet Gas Pressure option
order with a “-879”, and add ...............................................................
n For propane gas models change suffix “N” to “X” and remove “E” from the model number.
Example: EF-100T-150-3X, and add .........................................................
to natural gas net prices where applicable. Low NOx construction standard.
T&P Relief Valve installed and Hand Hole Cleanout is standard.
n Optional Condensate Neutralizer: P/N A2123601 (125,000 – 250,000 BTU/Hr.) ................
P/N A2123602 (300,000 BTU/Hr.) .........................
Ultra High Efficiency Models — ASME
Non-CFC Foam Insulation - 120 VAC required
$676.20
$736.05
$57.75
$67.20
$75.60
$102.90
$77.00
$40.00
$144.90
$235.20
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise
Floor to
Top of
Heater
Dia. Vent
Size
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
Price
H EF-60T-125E-3N 60 125,000 145 563⁄8" 281⁄4"3" or 4" 570
$6,558.00
EF-60T-150E-3N 60 150,000 169 563⁄8" 281⁄4"3" or 4" 570
8,825.00
EF-60T-199E-3N 60 199,999 223 563⁄8" 281⁄4"3" or 4" 570
8,975.00
H EF-100T-150E-3N 100 150,000 180 853⁄8" 281⁄4"3" or 4" 900
9,150.00
H EF-100T-199E-3N 100 199,999 239 853⁄8" 281⁄4"3" or 4" 900
9,195.00
H EF-100T-250E-3N 100 250,000 294 853⁄8" 281⁄4"3" or 4" 900
10,280.00
EF-100T-300E-3N 100 300,000 335 853⁄8" 281⁄4"3" or 4" 900
11,595.00
H EF-100T-399E-3N 100 399,999 451 853⁄8" 281⁄4"3" or 4" 950
12,895.00
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise
Floor to
Top of
Heater
Dia. Vent
Size
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
Price
HEF-60T-125E-3NA 60 125,000 145 563⁄8" 281⁄4"2", 3"or 4" 570
$8,375.00
EF-60T-150E-3NA 60 150,000 169 563⁄8" 281⁄4"2", 3"or 4" 570
10,040.00
EF-60T-199E-3NA 60 199,999 223 563⁄8" 281⁄4"2", 3"or 4" 570
10,500.00
HEF-100T-150E-3NA 100 150,000 180 853⁄8" 281⁄4"2", 3"or 4" 900
11,175.00
HEF-100T-199E-3NA 100 199,999 239 853⁄8" 281⁄4"2", 3"or 4" 900
11,195.00
HEF-100T-250E-3NA 100 250,000 294 853⁄8" 281⁄4"3" or 4" 900
12,300.00
EF-100T-300E-3NA 100 300,000 335 853⁄8" 281⁄4"3" or 4" 900
13,725.00
HEF-100T-399E-3NA 100 399,999 451 853⁄8" 281⁄4"3", 4"or 6" 950
14,905.00
H = ENERGY STAR® Qualified.
H = ENERGY STAR® Qualified.
15
Commercial Gas Models
Commercial Gas Models
Ultra High Efficiency Models — Non-ASME
Non-CFC Foam Insulation - 120 VAC required
Ultra High Efficiency Models — ASME
Non-CFC Foam Insulation - 120 VAC required
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise
Floor to
Top of
Heater
Dia. Vent
Size
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
Price
H EF-120T-400-3N 119 399,999 456 771⁄8" 33" 4" or 6" 1,120
$12,725.00
H EF-120T-500-3N 119 499,000 568 771⁄8" 33" 4" or 6" 1,135
14,665.00
Model
Number
Nominal
Capacity
(Gal.)
Input
BTU/Hr.
GPH Rec.
100°F Rise
Floor to
Top of
Heater
Dia. Vent
Size
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
Price
H EF-120T-400-3NA 119 399,999 456 771⁄8" 33" 4" or 6" 1,120
$14,715.00
H EF-120T-500-3NA 119 499,000 568 771⁄8" 33" 4" or 6" 1,135
16,075.00
H = ENERGY STAR® Qualified.
H = ENERGY STAR® Qualified.
Product Options
n NSF Compliance Kit—p/n 265-44542-04 ....................................................................................................................
$75.60
16
Commercial Electric Models
Commercial Electric Models
All models are UL and/or ETL listed. All water connections are 3/4" NPT (LE2120T3-3 has 1" NPT). All electrical connections are 3/4". All
models are certified at 300 psi test pressure and 150 psi working pressure. All models come equipped with two installed heat traps (except
LE2120T, LE120L, and Utility and Wall Hung Models). T&P Valve Installed.
Voltage
Wattage
Limitations
1500W / 1500W
2000W / 2000W
2500W / 2500W
3000W / 3000W
3500W / 3500W
4000W / 4000W
4500W / 4500W
5000W / 5000W
5500W / 5500W
6000W / 6000W
yes
no
no
no
no
no
no
no
no
no
120V
yes
yes
yes
yes
yes
yes
yes
yes
no
no
208V
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
240V
yes
yes
yes
yes
no
yes
yes
yes
yes
yes
277V
yes
yes
yes
yes
no
yes
yes
yes
yes
yes
480V
ElectriFLEX LD™ Light Duty Commercial Upright Models
Non-CFC Foam Insulation
n NSF Kit: P/N
265-44542-04 ..............................................................
For voltage and wattage conversions, order one of the kits from chart below.
For INCOLOY® Elements add . . . $8.00 for each element. No additional charges for 277 volt or 480 volt.
ElectriFLEX LD™ Light Duty Commercial Lowboy Models
Non-CFC Foam Insulation
* Dimension does not include additional insulation blanket.
** Models include supplied insulation blanket.
n NSF Kit: P/N
265-44542-04 ..............................................................
For voltage and wattage conversions, order one of the kits from chart below.
For INCOLOY® Elements add . . . $8.00 for each element. No additional charges for 277 volt or 480 volt.
NOTE: WHEN ORDERING WATER HEATERS SPECIFY VOLTAGE AND kW INPUT ONLY.
THE FOLLOWING TABLES ARE FOR INFORMATIONAL PURPOSES ONLY.
Phase and Operation are determined by the voltage.
All 208V, 240V and 480V models are shipped standard three phase, non-simultaneous.
Can be converted to single phase and/or simultaneous operation in the field.
All 120V and 277V models are shipped standard single phase, non-simultaneous.
Can be converted to simultaneous operation in the field. Three phase not available.
Commercial Light Duty Upright and Lowboy Model Number Suffix
Phase 1 Single Phase
3 Three Phase
EX: LE250S3-3NCWW
Operation N Non-Simultaneous
S Simultaneous
EX: LE250S3-3NCWW
Designator J K L M N P R S T W X Y Z
Wattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 6000
EX: LE250S3-3NCWW
Designator A C E H J L*
Voltage 120 208/240 277 480 600 208
EX: LE250S3-3NCWW
* Use “L” voltage designator if wiring 208V with 4500W or 5000W.
For 120V, 277V, 480V, and 600V operation
EX: LE250S3-3NCWW, will give 240V with 4500W/4500W. This same heater can also be energized at 208V with reduced wattage of
3500W/3500W.
** Use “L” voltage designator if wiring 208V with 4500W or 5000W.
For 240V and 208V operation (Dual rated elements show a value for both 240V and 208V)
Designator J K L M N P R S T W X Y Z X** Y** Z**
240V Wattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 — — — —
208V Wattage — — 1000 1500 2000 — 2500 — 3000 3500 — 4000 4500 5000 — —
$75.60
$75.60
Model Nominal Floor to Top Floor to Jacket Approx.
Number Capacity (Gal.) of Heater Water Conn. Dia. Shpg. Wt.
LE230S3-3 30 461⁄8" 473⁄4" 18" 85
LE240S3-3 40 475⁄8" 483⁄4" 20" 103
LE250S3-3 50 475⁄8" 489⁄16" 22" 130
LE265T3-3 65 60" 61" 22" 156
LE280T3-3 80 60" 61" 24" 183
LE2120T3-3 119 63" 6413⁄16" 28" 305
Limited 3 Year Tank Warranty
Price
$1,850.00
2,025.00
2,270.00
2,595.00
2,880.00
4,040.00
Model Nominal Floor to Top Floor to Jacket Approx.
Number Capacity (Gal.) of Heater Water Conn. Dia. Shpg. Wt.
LE120L3-3 19 243⁄4" 253⁄4" 18" 58
LE130L3-3** 30 30" 323⁄4" 20"* 86
LE140L3-3** 40 3213⁄16" 333⁄4" 22"* 115
LE150L3-3** 47 3213⁄16" 341⁄2" 24"* 140
Limited 3 Year Tank Warranty
Price
$910.00
1,845.00
2,110.00
2,340.00
17
Commercial Electric Models
Commercial Electric Models
Voltage and Wattage Conversion Kits for Upright and Lowboy Models
Note: Above chart can be used to determine maximum wattage at certain voltages.
**INCOLOY
®
element only.
Each kit will include two replacement elements, two gaskets, a rating plate overlay and one set of instructions. For water heaters
with only one element, please retain the extra element and gasket as a service part.
Simultaneous and
Voltage
Non-Simultaneous
Wattage
120 208 240 277 380 415 480
1500/1500 265-46409-01 265-46409-05 265-46409-13 265-46409-16 265-46409-24 265-46409-41 265-46409-32
Price
2000/2000 N/A 265-46409-06 265-46409-05 265-46409-17 265-46409-43 265-46409-24 265-46409-33
Price N/A
2500/2500 N/A 265-46409-07 265-46409-06 265-46409-18 265-46409-25 265-46409-43 265-46409-34
Price N/A
3000/3000 N/A 265-46409-08 265-46409-14 265-46409-19 265-46409-26 265-46409-25 265-46409-35
Price N/A
3500/3500 N/A 265-46409-09 265-46409-07 N/A 265-46409-27 265-46409-26 N/A
Price N/A N/A N/A
4000/4000 N/A 265-46409-10 265-46409-08 265-46409-20 265-46409-29 265-46409-27 265-46409-36
Price N/A
4500/4500 N/A 265-46409-11 265-46409-09 265-46409-21 265-46409-30 265-46409-28 265-46409-37
Price N/A
5000/5000 N/A 265-46409-12 265-46409-15 265-46409-22 265-46409-31 265-46409-29 265-46409-38
Price N/A
5500/5500 N/A N/A 265-46409-10 265-46409-40** 265-46409-44 265-46409-30 265-46409-42**
Price N/A N/A
6000/6000 N/A N/A N/A 265-46409-23 265-46409-45 265-46409-31 265-46409-39
Price N/A N/A N/A
All models are UL and/or ETL listed. All water connections are 3/4" NPT (LE2120T has 1" NPT). All electrical connections are 3/4". All models
are certified at 300 psi test pressure and 150 psi working pressure. All models come equipped with two installed heat traps (Except LE2120T,
LE120L, and Utility and Wall Hung Models). T&P Valve Installed.
Voltage
Wattage
Limitations
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
yes
yes
yes
yes
no
no
no
no
no
no
120V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
208V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
240V
yes
yes
yes
yes
no
yes
yes
yes
yes
yes
277V
yes
yes
yes
yes
no
yes
yes
yes
yes
yes
480V
NOTE: WHEN ORDERING WATER HEATERS SPECIFY VOLTAGE AND kW INPUT ONLY.
THE FOLLOWING TABLES ARE FOR INFORMATIONAL PURPOSES ONLY.
All models (120V, 208V, 240V, 277V and 480V) are shipped standard single phase,
non-simultaneous. Three phase, simultaneous operation is not available.
Commercial Light Duty Utility and Wall Hung Model Number Suffix
Phase 1 Single Phase
3 Three Phase
EX: LE120U3-1NAL
Operation N Non-Simultaneous
S Simultaneous
EX: LE120U3-1NAL
Designator A C E H J L*
Voltage 120 208/240 277 480 600 208
EX: LE120U3-1NAL
* Use “L” voltage designator if wiring 208V with 5000, 5500
or 6000 watt; also 2500W or 3000W on LE16U, LE112T, &
LE16WV models
Designator J K L* M N P R S T W X Y Z
Wattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 6000
EX: LE120U3-1NAL
* Use “L” voltage designator if wiring 208V with 2500W or 3000W on LE16U, LE112T, & LE16WV models.
For 120V, 277V, 480V, and 600V operation
EX: LE120U3-1NAL, will give 240V with 4500W/4500W. This same heater can also be energized at 208V with reduced wattage of
3500W/3500W.
** Use “L” voltage designator if wiring 208V with 5000, 5500 or 6000 watt.
† Available in non-simultaneous only.
For 240V and 208V operation (Dual rated elements show a value for both 240V and 208V)
Designator J K L M N P R S T W X Y Z X** Y** Z**
240V Wattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 6000 — — —
208V Wattage — — 1000 1500 2000 — 2500 — 3000 3500 — 4000 4500 5000 5500† 6000†
$34.65 $34.65 $34.65 $34.65 $57.75 $57.75 $34.65
$34.65 $34.65 $34.65 $57.75 $57.75 $34.65
$34.65 $34.65 $34.65 $57.75 $57.75 $34.65
$34.65 $34.65 $57.75 $57.75 $57.75 $57.75
$34.65 $34.65 $57.75 $57.75
$34.65 $34.65 $57.75 $57.75 $57.75 $57.75
$34.65 $34.65 $57.75 $57.75 $57.75 $57.75
$34.65 $34.65 $57.75 $57.75 $57.75 $57.75
$34.65 $57.75 $57.75 $57.75 $57.75
$57.75 $57.75 $57.75 $57.75
18
Commercial Electric Models
Commercial Electric Models
ElectriFLEX LD™ Light Duty Commercial Utility Models — Non-CFC Foam Insulation
†
Maximum wattage at any voltage is 3000W.
* Height bottom to top.
n NSF Kit: Kit Utility 265-44542-04 ..........................................................
For voltage and wattage conversions, order one of the kits from chart below.
The 6 and 12 gallon Utility models have water connections standard on the side and optional connections on the top.
For INCOLOY® Elements add . . . $8.00 for each element. No additional charges for 277 volt or 480 volt.
Voltage and Wattage Conversion Kits for Utility, Wall Hung and Single Element Heaters
Note: Above chart can be used to determine maximum wattage at certain voltages.
** INCOLOY® element only. * 265-46409-02, -03, -04, -46, -47, & -48 contain only one element.
These kits cannot be wired as simultaneous. These are non-simultaneous kits only.
Except where noted above, each kit will
include two replacement elements, two gaskets, a rating plate overlay and one set of instructions. For water heaters with only one
element, please retain the extra element and gasket as a service part.
Voltage
Single Element
Wattage
120 208 240 277 380 415 480
1500 265-46409-01 265-46409-05 265-46409-13 265-46409-16 265-46409-24 265-46409-41 265-46409-32
Price
2000 265-46409-02* 265-46409-06 265-46409-05 265-46409-17 265-46409-43 265-46409-24 265-46409-33
Price
2500 265-46409-03* 265-46409-07 265-46409-06 265-46409-18 265-46409-25 265-46409-43 265-46409-34
Price
3000 265-46409-04* 265-46409-08 265-46409-14 265-46409-19 265-46409-26 265-46409-25 265-46409-35
Price
3500 N/A 265-46409-09 265-46409-07 N/A 265-46409-27 265-46409-26 N/A
Price N/A N/A N/A
4000 N/A 265-46409-10 265-46409-08 265-46409-20 265-46409-29 265-46409-27 265-46409-36
Price N/A
4500 N/A 265-46409-11 265-46409-09 265-46409-21 265-46409-30 265-46409-28 265-46409-37
Price N/A
5000 N/A 265-46409-12 265-46409-15 265-46409-22 265-46409-31 265-46409-29 265-46409-38
Price N/A
5500 N/A 265-46409-46* 265-46409-10 265-46409-40** 265-46409-44 265-46409-30 265-46409-42**
Price N/A
6000 N/A 265-46409-47* 265-46409-48* 265-46409-23 265-46409-45 265-46409-31 265-46409-39
Price N/A
ElectriFLEX LD™ Light Duty Commercial Wall Hung Models
Non-CFC Foam Insulation
†
Maximum wattage at any voltage is 3000W.
* Height bottom to top.
n NSF Kit: Wall Hung 265-44542-05 .........................................................
For voltage and wattage conversions, order one of the kits from chart below.
For INCOLOY® Elements add . . . $8.00 for each element. No additional charges for 277 volt or 480 volt.
$75.60
$39.90
$34.65 $34.65 $34.65 $34.65 $57.75 $57.75 $34.65
$26.25 $34.65 $34.65 $34.65 $57.75 $57.75 $34.65
$26.25 $34.65 $34.65 $34.65 $57.75 $57.75 $34.65
$26.25 $34.65 $34.65 $57.75 $57.75 $57.75 $57.75
$34.65 $34.65 $57.75 $57.75
$34.65 $34.65 $57.75 $57.75 $57.75 $57.75
$34.65 $34.65 $57.75 $57.75 $57.75 $57.75
$34.65 $34.65 $57.75 $57.75 $57.75 $57.75
$57.75 $34.65 $57.75 $57.75 $57.75 $57.75
$57.75 $57.75 $57.75 $57.75 $57.75 $57.75
Model Nominal Floor to Top Floor to Jacket Approx.
Number
Capacity (Gal.)
of Heater Hot Water Conn. Dia. Shpg. Wt.
LE16U3-1† 6 161⁄2" 101⁄8" 14" 33
LE110U3-1 10 171⁄2" 15" 16" 48
LE112T3-1† 12 273⁄4" 211⁄8" 14" 48
LE115U3-1 15 201⁄4" 173⁄4" 18" 55
LE120U3-1 19 243⁄4" 181⁄2" 18" 59
Price
$735.00
790.00
830.00
840.00
905.00
Model Nominal Height Wall to Height to Height to Jacket Approx.
Number
Cap. (Gal.)
of Heater Front Bracket T&P Conn. Dia. Shpg. Wt.
LE16WV3-1† 6 161⁄8" 145⁄8" 12 12" 14" 33
LE112WV-3-1 12 161⁄2" 185⁄8" 121⁄2" 13" 18" 48
LE120WV-3-1 19 241⁄2" 185⁄8" 181⁄4" 21" 18" 59
Price
$870.00
930.00
1,020.00
19
Commercial Electric Models
Commercial Electric Models
Commercial ElectriFLEX MD™ Model Number Suffix
Required
Total Heater
kW 208 Volts 240 Volts 480 Volts Price
6 265-43942-13 265-43942-07 265-43942-01
9 265-43942-14 265-43942-08 265-43942-02
12 265-43942-15 265-43942-09 265-43942-03
13.5 265-43942-16 265-43942-10 265-43942-04
15 265-43942-17 265-43942-11 265-43942-05
18 — 265-43942-12 265-43942-06
18 265-43942-18 — —
Field Conversion Kit For ElectriFLEX MD™ Models
Kit Part Numbers
ElectriFLEX MD™ Commercial Models
2" Non-CFC Foam Insulation
All Medium Duty water heaters are wired 240v, 3 phase, 18kW as standard.
Other wattages, wiring phase, and kW are available and must be specified when ordering.
All 277V models are shipped standard single phase. Three phase not available.
No additional charges for 277 volt or 480 volt.
Phase 1 Single Phase
3 Three Phase
EX: E32-120R-3-3C18, Three Phase 240V, 18kW.
Designator 06 09 12 135 15 18
Wattage 6000 9000 12000 13500 15000 18000
EX: E32-120R-3-3C18
Designator L C E H
Voltage 208 240 277 480
EX: E32-120R-3-3C18
NOTE: WHEN ORDERING WATER HEATERS SPECIFY VOLTAGE, PHASE AND WATTAGE. THE FOLLOWING TABLES ARE FOR
INFORMATIONAL PURPOSES ONLY.
Product Options
n NSF Compliance Kits:
P/N 265-45446-01 (50S) ...................................................................
P/N 265-45446-02 (80R) ...................................................................
P/N 265-45446-03 (120R) ..................................................................
$39.90
$39.90
$39.90
$75.60
75.60
75.60
75.60
75.60
75.60
479.85
Model Nominal Floor to Top Floor to Jacket Floor to Floor to Control Box to Approx.
Number
Cap. (Gal.)
of Heater Water Conn. Dia. T&P Conn. Control Box Back of Heater Shpg. Wt.
E32-50S-3 50 471⁄4" 477⁄8" 22" 481⁄8" 441⁄2" 245⁄8" 137
E32-80R-3 80 593⁄4" 61" 24" 613⁄8" 57" 265⁄8" 190
E32-120R-3 119 63" 645⁄8" 281⁄4" 65" 611⁄2" 307⁄8" 312
Limited 3 Year
Tank Warranty
Price
$3,000.00
3,600.00
4,100.00
20
Commercial Electric Models
Commercial Electric Models
ElectriFLEX HD™ Commercial Models
ElectriFLEX HD™ Commercial Models — Non-ASME
3" Non-CFC Foam Insulation
Specify Voltage, Wattage, and Phase when ordering.
Product Options Add
For 277/480 volt (INCOLOY® Elements standard) ...........................
NSF Compliance Kits:
265-44542-01 CEHD-50 Models ...................................
265-44542-02 CEHD-80 Models ...................................
265-44542-03 CEHD-120 Models ..................................
$60.00
$75.60
$75.60
$75.60
Model
Number
Nominal
Cap. (Gal.)
Input
kW
Number of
Elements
GPH Rec.
100°F Rise
Jacket
Dia.
Floor to
Top of Htr.
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
CEHD-50-6-3CF 50 6 3 25 24" 507⁄16" 270 $3,320.00
CEHD-50-9-3CF 50 9 3 37 24" 507⁄16" 270 3,520.00
CEHD-50-12-3CF 50 12 3 50 24" 507⁄16" 270 3,530.00
CEHD-50-13.5-3CF 50 13.5 3 56 24" 507⁄16" 270 3,590.00
CEHD-50-15-3CF 50 15 3 62 24" 507⁄16" 270 3,590.00
CEHD-50-18-3CF 50 18 3 74 24" 507⁄16" 270 3,660.00
CEHD-50-24-3CF 50 24 6 99 24" 507⁄16" 270 4,990.00
CEHD-50-27-3CF 50 27 6 112 24" 507⁄16" 270 5,185.00
CEHD-50-30-3CF 50 30 6 124 24" 507⁄16" 270 5,310.00
CEHD-50-36-3CF 50 36 6 149 24" 507⁄16" 270 5,350.00
CEHD-50-45-3CF 50 45 9 186 24" 507⁄16" 270 7,250.00
CEHD-50-54-3CF 50 54 9 223 24" 507⁄16" 270 7,475.00
CEHD-80-6-3CF 80 6 3 25 26" 611⁄4" 335 $4,235.00
CEHD-80-9-3CF 80 9 3 37 26" 611⁄4" 335 4,430.00
CEHD-80-12-3CF 80 12 3 50 26" 611⁄4" 335 4,435.00
CEHD-80-13.5-3CF 80 13.5 3 56 26" 611⁄4" 335 4,490.00
CEHD-80-15-3CF 80 15 3 62 26" 611⁄4" 335 4,490.00
CEHD-80-18-3CF 80 18 3 74 26" 611⁄4" 335 4,570.00
CEHD-80-24-3CF 80 24 6 99 26" 611⁄4" 335 5,870.00
CEHD-80-27-3CF 80 27 6 112 26" 611⁄4" 335 6,070.00
CEHD-80-30-3CF 80 30 6 124 26" 611⁄4" 335 6,180.00
CEHD-80-36-3CF 80 36 6 149 26" 611⁄4" 335 6,210.00
CEHD-80-45-3CF 80 45 9 186 26" 611⁄4" 335 7,700.00
CEHD-80-54-3CF 80 54 9 223 26" 611⁄4" 335 7,830.00
CEHD-120-6-3CF 119 6 3 25 301⁄4" 6411⁄16" 430 $5,025.00
CEHD-120-9-3CF 119 9 3 37 301⁄4" 6411⁄16" 430 5,230.00
CEHD-120-12-3CF 119 12 3 50 301⁄4" 6411 ⁄16" 430 5,235.00
CEHD-120-13.5-3CF 119 13.5 3 56 301⁄4" 6411⁄16" 430 5,245.00
CEHD-120-15-3CF 119 15 3 62 301⁄4" 6411 ⁄16" 430 5,245.00
CEHD-120-18-3CF 119 18 3 74 301⁄4" 6411⁄16" 430 5,350.00
CEHD-120-24-3CF 119 24 6 99 301⁄4" 6411⁄16" 430 6,660.00
CEHD-120-27-3CF 119 27 6 112 301⁄4" 6411⁄16" 430 6,825.00
CEHD-120-30-3CF 119 30 6 124 301⁄4" 6411⁄16" 430 6,970.00
CEHD-120-36-3CF 119 36 6 149 301⁄4" 6411⁄16" 430 6,990.00
CEHD-120-45-3CF 119 45 9 186 301⁄4" 6411⁄16" 430 8,545.00
CEHD-120-54-3CF 119 54 9 223 301⁄4" 6411⁄16" 430 8,625.00
NOTE WHEN ORDERING WATER HEATERS SPECIFY VOLTAGE AND kW INPUT.
THE FOLLOWING TABLES ARE FOR INFORMATIONAL PURPOSES ONLY.
All 208V, 240V and 480V models are shipped standard three phase.
Can be converted to single phase in the field.
All 277V models are shipped standard single phase. Three phase not available.
21
Commercial Electric Models
Commercial Electric Models
For 277/480 volt (INCOLOY® Elements standard) ...........................
NSF Compliance Kits:
265-44542-01 CEHD-50 Models ...................................
265-44542-02 CEHD-80 Models ...................................
265-44542-03 CEHD-120 Models ..................................
$60.00
$75.60
$75.60
$75.60
ElectriFLEX HD™ Commercial Models — ASME
3" Non-CFC Foam Insulation
Specify Voltage, Wattage, and Phase when ordering.
Product Options Add
ASME Construction
For ASME Construction add “A” to model number as displayed
Model
Number
Nominal
Cap. (Gal.)
Input
kW
Number of
Elements
GPH Rec.
100°F Rise
Jacket
Dia.
Floor to
Top of Htr.
Approx.
Shpg. Wt.
Limited 3 Year
Tank Warranty
CEHD-50A-6-3CF 50 6 3 25 24" 507⁄16" 302 $3,805.00
CEHD-50A-9-3CF 50 9 3 37 24" 507⁄16" 302 3,995.00
CEHD-50A-12-3CF 50 12 3 50 24" 507⁄16" 302 4,000.00
CEHD-50A-13.5-3CF 50 13.5 3 56 24" 507⁄16" 302 4,100.00
CEHD-50A-15-3CF 50 15 3 62 24" 507⁄16" 302 4,100.00
CEHD-50A-18-3CF 50 18 3 74 24" 507⁄16" 302 4,140.00
CEHD-50A-24-3CF 50 24 6 99 24" 507⁄16" 302 5,450.00
CEHD-50A-27-3CF 50 27 6 112 24" 507⁄16" 302 5,650.00
CEHD-50A-30-3CF 50 30 6 124 24" 507⁄16" 302 5,770.00
CEHD-50A-36-3CF 50 36 6 149 24" 507⁄16" 302 5,800.00
CEHD-50A-45-3CF 50 45 9 186 24" 507⁄16" 302 7,795.00
CEHD-50A-54-3CF 50 54 9 223 24" 507⁄16" 302 7,620.00
CEHD-80A-6-3CF 80 6 3 25 26" 611⁄4" 378 $4,750.00
CEHD-80A-9-3CF 80 9 3 37 26" 611⁄4" 378 4,940.00
CEHD-80A-12-3CF 80 12 3 50 26" 611⁄4" 378 4,955.00
CEHD-80A-13.5-3CF 80 13.5 3 56 26" 611⁄4" 378 5,010.00
CEHD-80A-15-3CF 80 15 3 62 26" 611⁄4" 378 5,010.00
CEHD-80A-18-3CF 80 18 3 74 26" 611⁄4" 378 5,070.00
CEHD-80A-24-3CF 80 24 6 99 26" 611⁄4" 378 6,400.00
CEHD-80A-27-3CF 80 27 6 112 26" 611⁄4" 378 6,580.00
CEHD-80A-30-3CF 80 30 6 124 26" 611⁄4" 378 6,680.00
CEHD-80A-36-3CF 80 36 6 149 26" 611⁄4" 378 6,700.00
CEHD-80A-45-3CF 80 45 9 186 26" 611⁄4" 378 8,240.00
CEHD-80A-54-3CF 80 54 9 223 26" 611⁄4" 378 8,410.00
CEHD-120A-6-3CF 119 6 3 25 301⁄4" 6411⁄16" 485 $5,500.00
CEHD-120A-9-3CF 119 9 3 37 301⁄4" 6411⁄16" 485 5,690.00
CEHD-120A-12-3CF 119 12 3 50 301⁄4" 6411 ⁄16" 485 5,720.00
CEHD-120A-13.5-3CF 119 13.5 3 56 301⁄4" 6411 ⁄16" 485 5,795.00
CEHD-120A-15-3CF 119 15 3 62 301⁄4" 6411 ⁄16" 485 5,795.00
CEHD-120A-18-3CF 119 18 3 74 301⁄4" 6411⁄16" 485 5,850.00
CEHD-120A-24-3CF 119 24 6 99 301⁄4" 6411⁄16" 485 7,130.00
CEHD-120A-27-3CF 119 27 6 112 301⁄4" 6411⁄16" 485 7,200.00
CEHD-120A-30-3CF 119 30 6 124 301⁄4" 6411⁄16" 485 7,320.00
CEHD-120A-36-3CF 119 36 6 149 301⁄4" 6411⁄16" 485 7,440.00
CEHD-120A-45-3CF 119 45 9 186 301⁄4" 6411⁄16" 485 8,920.00
CEHD-120A-54-3CF 119 54 9 223 301⁄4" 6411⁄16" 485 9,155.00
Commercial Electric Models
22
Commercial Electric Models
Model
Number
Desired Input Conversion Kit Part Numbers***
Total
kW
Element
kW 208 Volts 240 Volts 277 Volts 380 Volts 415 Volts
480 Volts 600 Volts*
CEHD with
3 Elements
6 2
265-51043-73
Price
$72.00
265-51043-61
Price
$72.00
265-51043-49
Price
$72.00
265-51043-37
Price
$72.00
265-51043-25
Price
$72.00
265-51043-13
Price
$72.00
265-51043-01
Price
$72.00
9 3
265-51043-74
Price
$72.00
265-51043-62
Price
$72.00
265-51043-50
Price
$72.00
265-51043-38
Price
$72.00
265-51043-26
Price
$72.00
265-51043-14
Price
$72.00
265-51043-02
Price
$72.00
12 4
265-51043-75
Price
$72.00
265-51043-63
Price
$72.00
265-51043-51
Price
$72.00
265-51043-39
Price
$72.00
265-51043-27
Price
$72.00
265-51043-15
Price
$72.00
265-51043-03
Price
$72.00
13.5 4.5
265-51043-76
Price
$72.00
265-51043-64
Price
$72.00
265-51043-52
Price
$72.00
265-51043-40
Price
$72.00
265-51043-28
Price
$72.00
265-51043-16
Price
$72.00
265-51043-04
Price
$72.00
15 5
265-51043-77
Price
$72.00
265-51043-65
Price
$72.00
265-51043-53
Price
$72.00
265-51043-41
Price
$72.00
265-51043-29
Price
$72.00
265-51043-17
Price
$72.00
265-51043-05
Price
$72.00
18 6
265-51043-78
Price
$72.00
265-51043-66
Price
$72.00
265-51043-54
Price
$72.00
265-51043-42
Price
$72.00
265-51043-30
Price
$72.00
265-51043-18
Price
$72.00
265-51043-06
Price
$72.00
CEHD with
6 Elements
24 4
265-51043-79
Price
$124.00
265-51043-67
Price
$124.00
265-51043-55
Price
$124.00
265-51043-43
Price
$124.00
265-51043-31
Price
$124.00
265-51043-19
Price
$124.00
265-51043-07
Price
$124.00
27 4.5
265-51043-80
Price
$124.00
265-51043-68
Price
$124.00
265-51043-56
Price
$124.00
265-51043-44
Price
$124.00
265-51043-32
Price
$124.00
265-51043-20
Price
$124.00
265-51043-08
Price
$124.00
30 5
265-51043-81
Price
$124.00
265-51043-69
Price
$124.00
265-51043-57
Price
$124.00
265-51043-45
Price
$124.00
265-51043-33
Price
$124.00
265-51043-21
Price
$124.00
265-51043-09
Price
$124.00
36 6
265-51043-82
Price
$124.00
265-51043-70
Price
$124.00
265-51043-58
Price
$124.00
265-51043-46
Price
$124.00
265-51043-34
Price
$124.00
265-51043-22
Price
$124.00
265-51043-10
Price
$124.00
CEHD with
9 Elements
45 5
265-51043-83
Price
$175.00
265-51043-71
Price
$175.00
265-51043-59
Price
$175.00
265-51043-47
Price
$175.00
265-51043-35
Price
$175.00
265-51043-23
Price
$175.00
265-51043-11
Price
$175.00
54 6
265-51043-84**
Price
$175.00
265-51043-72
Price
$175.00
265-51043-60
Price
$175.00
265-51043-48
Price
$175.00
265-51043-36
Price
$175.00
265-51043-24
Price
$175.00
265-51043-12
Price
$175.00
* Only kW conversion is allowed for models rated 600V. Models rated 480V and below must not be converted to 600V.
** Only available as a three phase conversion kit.
Note
3 element models may convert 6 kW thru 18 kW ONLY
6 element models may convert 24 kW thru 36 kW ONLY
9 element models may convert 45 kW thru 54 kW ONLY
From
*** Converting 6 or 9 element configurations (24-54kW)
208/240/480 Volt
277/380/415 Volt
208/240/480 Volt
277/380/415 Volt
To
277/380/415 Volt
208/240/480 Volt
208/240/480 Volt
277/380/415 Volt
Transformer Required
264-41995-02
264-41995-01
No Transformer Change Required
No Transformer Change Required
From
*** Converting 3 Element Configurations (6-18kW)
208/240/480 Volt
277/380/415 Volt
208/240/480 Volt
277/380/415 Volt
To
277/380/415 Volt
208/240/480 Volt
208/240/480 Volt
277/380/415 Volt
Transformer Required
264-41994-02
264-41994-01
No Transformer Change Required
No Transformer Change Required
ElectriFLEX HD™ Commercial Models — ASME
3" Non-CFC Foam Insulation
Commercial Electric Models
23
Commercial Electric Models
ASME Models
Commercial ASME Models
2" Non-CFC Foam Insulation
Number of Elements
Model Input Single Three Floor to Floor to Floor to Jacket Approx.
Number kW Phase Phase Top of Heater CW Inlet HW Outlet Dia. Shpg. Wt.
6A-3-3 6 3 1 1 171⁄8" 61⁄8" 181⁄4" 16" 83
12A-3-3 12 3 1 1 28" 61⁄8" 29" 16" 118
12A-6-3 12 6 3 3 28" 61⁄8" 29" 16" 118
12A-9-3 12 9 3 3 28" 61⁄8" 29" 16" 118
20A-3-3 20 3 1 1 275⁄8" 61⁄8" 281⁄2" 20" 145
20A-6-3 20 6 3 3 275⁄8" 61⁄8" 281⁄2" 20" 145
20A-9-3 20 9 3 3 275⁄8" 61⁄8" 281⁄2" 20" 145
20A-12-3 20 12 3 3 275⁄8" 61⁄8" 281⁄2" 20" 145
20A-13.5-3 20 13.5 3 3 275⁄8" 61⁄8" 281⁄2" 20" 145
20A-15-3 20 15 3 3 275⁄8" 61⁄8" 281⁄2" 20" 145
20A-18-3 20 18 3 3 275⁄8" 61⁄8" 281⁄2" 20" 145
30A-3-3 30 3 1 1 38" 61⁄8" 39" 20" 180
30A-6-3 30 6 3 3 38" 61⁄8" 39" 20" 180
30A-9-3 30 9 3 3 38" 61⁄8" 39" 20" 180
30A-12-3 30 12 3 3 38" 61⁄8" 39" 20" 180
30A-13.5-3 30 13.5 3 3 38" 61⁄8" 39" 20" 180
30A-15-3 30 15 3 3 38" 61⁄8" 39" 20" 180
30A-18-3 30 18 3 3 38" 61⁄8" 39" 20" 180
30A-24-3 30 24 4 6 38" 61⁄8" 39" 20" 180
30A-27-3 30 27 6 6 38" 61⁄8" 39" 20" 180
30A-30-3 30 30 6 6 38" 61⁄8" 39" 20" 180
30A-36-3 30 36 6 6 38" 61⁄8" 39" 20" 180
40A-3-3 40 3 1 1 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-6-3 40 6 3 3 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-9-3 40 9 3 3 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-12-3 40 12 3 3 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-13.5-3 40 13.5 3 3 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-15-3 40 15 3 3 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-18-3 40 18 3 3 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-24-3 40 24 4 6 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-27-3 40 27 6 6 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-30-3 40 30 6 6 481⁄4" 61⁄8" 491⁄4" 20" 220
40A-36-3 40 36 6 6 481⁄4" 61⁄8" 491⁄4" 20" 220
50A-3-3 48 3 1 1 483⁄4" 7" 491⁄4" 24" 270
50A-6-3 48 6 3 3 483⁄4" 7" 491⁄4" 24" 270
50A-9-3 48 9 3 3 483⁄4" 7" 491⁄4" 24" 270
50A-12-3 48 12 3 3 483⁄4" 7" 491⁄4" 24" 270
50A-13.5-3 48 13.5 3 3 483⁄4" 7" 491⁄4" 24" 270
50A-15-3 48 15 3 3 483⁄4" 7" 491⁄4" 24" 270
50A-18-3 48 18 3 3 483⁄4" 7" 491⁄4" 24" 270
50A-24-3 48 24 4 6 483⁄4" 7" 491⁄4" 24" 270
50A-27-3 48 27 6 6 483⁄4" 7" 491⁄4" 24" 270
50A-30-3 48 30 6 6 483⁄4" 7" 491⁄4" 24" 270
50A-36-3 48 36 6 6 483⁄4" 7" 491⁄4" 24" 270
50A-45-3 48 45 9 9 483⁄4" 7" 491⁄4" 24" 270
50A-54-3 48 54 9 9 483⁄4" 7" 491⁄4" 24" 270
50A-81-3 48 81 9 9 483⁄4" 7" 491⁄4" 24" 270
Specify Voltage, Wattage, and Phase when ordering.
All models available in 208, 240, 277 and 480 volt at above prices.
All 277V models are shipped standard single phase. Three phase not available.
INCOLOY® elements standard.
Hand Hole cleanout opening standard, except 6 and 12 gallon models.
T&P relief valve supplied (not installed) with heater.
$3,944.00
4,114.00
4,375.00
4,751.00
4,298.00
4,504.00
4,919.00
5,003.00
5,273.00
5,273.00
5,430.00
4,478.00
4,712.00
4,969.00
5,207.00
5,369.00
5,369.00
5,624.00
5,817.00
7,127.00
7,732.00
7,813.00
Limited 3 Year
Tank Warranty
Price
$4,641.00
4,859.00
5,094.00
5,369.00
5,574.00
5,574.00
5,767.00
5,993.00
7,371.00
7,949.00
8,602.00
$5,921.00
5,978.00
6,038.00
6,213.00
6,237.00
6,303.00
6,383.00
8,410.00
8,824.00
8,914.00
9,179.00
10,871.00
11,040.00
18,185.00
Nom.
Cap.
(Gal.)
24
Commercial Electric Models
Commercial Electric Models
Options
Low Water Cut-Off Switch .............................. $285.00
Safety Door Interlock .................................. $510.00
High and Low Pressure Limit Switches .................... $485.00
Alarm Horn .......................................... $545.00
Temperature and Pressure Gauge ........................ $155.00
Time Delay Step Sequence (24 kW & above) ................ $353.00
BMS Relay ........................................... $88.00
NSF Compliance Kit: P/N 265-44542-04 ................. $75.60
Number of Elements
Model Input Single Three Floor to Floor to Floor to Jacket Approx.
Number kW Phase Phase Top of Heater CW Inlet HW Outlet Dia. Shpg. Wt.
80A-3-3 78 3 1 1 601⁄4" 7" 613⁄4" 26" 335
80A-6-3 78 6 3 3 601⁄4" 7" 613⁄4" 26" 335
80A-9-3 78 9 3 3 601⁄4" 7" 613⁄4" 26" 335
80A-12-3 78 12 3 3 601⁄4" 7" 613⁄4" 26" 335
80A-13.5-3 78 13.5 3 3 601⁄4" 7" 613⁄4" 26" 335
80A-15-3 78 15 3 3 601⁄4" 7" 613⁄4" 26" 335
80A-18-3 78 18 3 3 601⁄4" 7" 613⁄4" 26" 335
80A-24-3 78 24 4 6 601⁄4" 7" 613⁄4" 26" 335
80A-27-3 78 27 6 6 601⁄4" 7" 613⁄4" 26" 335
80A-30-3 78 30 6 6 601⁄4" 7" 613⁄4" 26" 335
80A-36-3 78 36 6 6 601⁄4" 7" 613⁄4" 26" 335
80A-45-3 78 45 9 6 601⁄4" 7" 613⁄4" 26" 335
80A-54-3 78 54 9 9 601⁄4" 7" 613⁄4" 26" 335
80A-81-3 78 81 9 9 601⁄4" 7" 613⁄4" 26" 335
Commercial ASME Models
2" Non-CFC Foam Insulation
120A-3-3 119 3 1 1 6411⁄16" 7" 66" 301⁄4" 430
120A-6-3 119 6 3 3 6411 ⁄16" 7" 66" 301⁄4" 430
120A-9-3 119 9 3 3 6411 ⁄16" 7" 66" 301⁄4" 430
120A-12-3 119 12 3 3 6411⁄16" 7" 66" 301⁄4" 430
120A-13.5-3 119 13.5 3 3 6411 ⁄16" 7" 66" 301⁄4" 430
120A-15-3 119 15 3 3 6411⁄16" 7" 66" 301⁄4" 430
120A-18-3 119 18 3 3 6411⁄16" 7" 66" 301⁄4" 430
120A-24-3 119 24 4 6 6411⁄16" 7" 66" 301⁄4" 430
120A-27-3 119 27 6 6 6411⁄16" 7" 66" 301⁄4" 430
120A-30-3 119 30 6 6 6411⁄16" 7" 66" 301⁄4" 430
120A-36-3 119 36 6 6 6411⁄16" 7" 66" 301⁄4" 430
120A-45-3 119 45 9 9 6411⁄16" 7" 66" 301⁄4" 430
120A-54-3 119 54 9 9 6411⁄16" 7" 66" 301⁄4" 430
120A-81-3 119 81 9 9 6411⁄16" 7" 66" 301⁄4" 430
No additional charges for 277 volt or 480 volt.
Limited 3 Year
Tank Warranty
Price
$7,285.00
7,355.00
7,355.00
7,404.00
7,450.00
7,524.00
7,575.00
9,478.00
9,855.00
9,953.00
10,230.00
11,821.00
11,973.00
18,736.00
$8,739.00
8,828.00
8,828.00
8,916.00
9,006.00
9,099.00
9,360.00
10,358.00
10,752.00
10,859.00
11,119.00
12,627.00
12,779.00
19,267.00
Nom.
Cap.
(Gal.)
25
Commercial Electric Models
Commercial Electric Models
Electric Brute™ Models
Immersion Thermostats
VERTICAL ROUND MODELS
Three Year Limited Tank Warranty
Commercial multipliers (CSDs) are not applicable to
this product. Please call your local Bradford White
sales representative for pricing.
Electric Brute™ Vertical Round
Volts: 208V, 240V, and 277V
Model
Number 12kW 15kW 18kW 30kW 36kW Max
kW Load
Approx.
Shpg. Wt.
VR-150-(kW) $19,388.00 $19,527.00 $19,694.00 $20,211.00 $20,655.00 90 650
VR-200-(kW) 20,304.00 20,440.00 20,610.00 $21,084.00 21,478.00 162 750
VR-250-(kW) 20,919.00 21,057.00 21,224.00 21,766.00 22,395.00 162 1165
VR-300-(kW) 22,347.00 22,481.00 22,653.00 23,104.00 23,467.00 162 1350
VR-400-(kW) 26,767.00 26,904.00 27,072.00 27,540.00 27,834.00 162 1590
VR-500-(kW) 31,136.00 31,270.00 31,442.00 31,922.00 32,170.00 162 1700
VR-600-(kW) 36,333.00 36,467.00 36,639.00 37,094.00 37,351.00 216 2010
VR-800-(kW) 42,435.00 42,435.00 42,601.00 43,081.00 43,305.00 270 2450
VR-1000-(kW) 47,645.00 47,645.00 47,818.00 48,284.00 48,529.00 360 3160
VR-1250-(kW) 49,568.00 49,568.00 49,568.00 50,270.00 50,973.00 360 3792
VR-1500-(kW) 54,309.00 54,309.00 54,309.00 55,013.00 55,718.00 360 4550
VR-2000-(kW) 70,275.00 70,275.00 70,275.00 71,034.00 71,794.00 360 5460
VR-2500-(kW) 75,370.00 75,370.00 75,370.00 76,071.00 76,772.00 360 6553
Volts: 208V, 240V, and 277V
Model
Number 45kW 54kW 60kW 72kW 90kW Max
kW Load
Approx.
Shpg. Wt.
VR-150-(kW) $21,947.00 $23,277.00 $23,476.00 $24,431.00 $25,537.00 90 650
VR-200-(kW) 23,272.00 24,611.00 24,801.00 25,911.00 27,021.00 162 750
VR-250-(kW) 24,242.00 25,580.00 25,771.00 26,732.00 27,932.00 162 1165
VR-300-(kW) 25,267.00 25,491.00 26,797.00 27,758.00 28,881.00 162 1350
VR-400-(kW) 29,405.00 30,739.00 30,934.00 31,895.00 32,944.00 162 1590
VR-500-(kW) 33,457.00 34,785.00 34,988.00 35,913.00 37,005.00 162 1700
VR-600-(kW) 38,410.00 39,741.00 39,939.00 40,713.00 41,541.00 216 2010
VR-800-(kW) 43,907.00 45,253.00 46,093.00 46,876.00 47,602.00 270 2450
VR-1000-(kW) 49,087.00 50,306.00 51,085.00 51,864.00 52,614.00 360 3160
VR-1250-(kW) 51,950.00 52,928.00 53,906.00 54,885.00 57,361.00 360 3792
VR-1500-(kW) 56,956.00 58,194.00 59,432.00 60,670.00 63,147.00 360 4550
VR-2000-(kW) 73,033.00 74,271.00 75,508.00 76,747.00 79,223.00 360 5460
VR-2500-(kW) 78,011.00 79,248.00 80,487.00 81,725.00 75,302.00 360 6553
* Not subject to Commercial Stocking Program
* Not subject to Commercial Stocking Program
These Products Are Net And Not Subject To Performance Incentive Program.
26
Commercial Electric Models
Commercial Electric Models
Electric Brute™ Vertical Round
Volts: 208V, 240V, and 277V
Model
Number 108kW 120kW 135kW 144kW 162kW Max
kW Load
Approx.
Shpg. Wt.
VR-150-(kW) — — — — — 90 650
VR-200-(kW) $28,880.00 $28,403.00 $29,436.00 $29,999.00 $32,753.00 162 750
VR-250-(kW) 29,628.00 29,874.00 30,242.00 30,725.00 33,318.00 162 1165
VR-300-(kW) 30,744.00 30,967.00 31,580.00 31,821.00 34,238.00 162 1350
VR-400-(kW) 34,789.00 35,024.00 35,401.00 35,969.00 38,499.00 162 1590
VR-500-(kW) 39,625.00 39,968.00 40,706.00 40,353.00 43,317.00 162 1700
VR-600-(kW) 43,320.00 43,548.00 43,920.00 44,055.00 47,357.00 216 2010
VR-800-(kW) 48,967.00 49,215.00 49,475.00 49,726.00 52,719.00 270 2450
VR-1000-(kW) 53,867.00 54,096.00 54,339.00 54,581.00 54,581.00 360 3160
VR-1250-(kW) 59,836.00 61,152.00 62,468.00 63,784.00 66,789.00 360 3792
VR-1500-(kW) 65,622.00 67,263.00 68,905.00 70,550.00 72,836.00 360 4550
VR-2000-(kW) 81,698.00 83,532.00 85,364.00 87,198.00 89,653.00 360 5460
VR-2500-(kW) 86,676.00 87,509.00 88,341.00 89,176.00 89,176.00 360 6553
Volts: 208V, 240V, and 277V
Model
Number 180kW 216kW 252kW 270kW 288kW 324kW 360kW Max
kW Load
Approx.
Shpg. Wt.
VR-150-(kW) — — — — — — — 90 650
VR-200-(kW) — — — — — — — 162 750
VR-250-(kW) — — — — — — — 162 1165
VR-300-(kW) — — — — — — — 162 1350
VR-400-(kW) — — — — — — — 162 1590
VR-500-(kW) — — — — — — — 162 1700
VR-600-(kW)
$64,503.00 $68,813.00
— — — — — 216 2010
VR-800-(kW)
62,695.00 66,718.00 $71,385.00 $72,555.00
— — — 270 2450
VR-1000-(kW)
67,398.00 71,788.00 77,121.00 78,875.00 $80,490.00 $85,534.00
— 360 3160
VR-1250-(kW)
69,795.00 74,692.00 81,054.00 82,537.00 84,019.00 89,548.00 $93,505.00
360 3792
VR-1500-(kW)
75,125.00 80,477.00 85,976.00 88,743.00 91,498.00 95,329.00 99,252.00
360 4550
VR-2000-(kW)
92,109.00 96,554.00 101,871.00 104,302.00 106,731.00 111,407.00 118,123.00
360 5460
VR-2500-(kW)
95,747.00 101,533.00 106,476.00
109,176.00
111,876.00 116,388.00 122,320.00
360 6553
Options
Alarm Bell ............................................................................. $279.00
BMS Contacts ...................................................................... $243.00
Manway ................................................................................ $485.00
Low Water Cut-off (LWCO) .................................................. $360.00
High or Low Water Pressure Switch .................................... $266.00
Pilot Lights and Switches ..................................................... $125.00
Safety Door Interlock ........................................................... $369.00
Seismic Bracing ................................................................... $233.00
Shunt Trip Disconnect ............................................. Consult Factory
Temperature Gauge ............................................................. $146.00
Pressure Gauge .................................................................... $146.00
Time Clock (24 hour) ............................................................ $340.00
Time Clock (7 day) ............................................................... $605.00
Double Vitraglas® Lining
(6-Year Limited Tank Warranty) .............................. Consult Factory
Solid State Step Controls:
1–4 steps .............................................................................. $704.00
5–8 steps ........................................................................... $1,698.00
9–12 steps ......................................................................... $2,746.00
Standard Equipment:
n ASME Construction
n 150 psi
n INCOLOY® heating elements
n Internal fusing (above 120 amps)
n Painted steel jacket
n Lifting Lug Access
n Magnesium anode rods
n Immersion Thermostats
n Magnetic contactors
n Manual reset high limit
n Hinged door with keyed lock
n ASME temperature & pressure relief valve
n Approved for 180ºF (82.2ºC) operation
*May require additional control box * Not subject to Commercial Stocking Program
*May require additional control box * Not subject to Commercial Stocking Program
These Products Are Net And Not Subject To Performance Incentive Program.
27
Commercial Electric Models
Commercial Electric Models
Electric Brute™ Vertical Round
Volts: 380V, 400V, 415V, 480V and 600V
Model
Number 12kW 15kW 18kW 30kW 36kW Max
kW Load
Approx.
Shpg. Wt.
VR-150-(kW) $18,419.00 $18,625.00 $18,884.00 $19,440.00 $19,725.00 90 650
VR-200-(kW) 19,533.00 19,738.00 19,997.00 20,456.00 20,744.00 162 750
VR-250-(kW) 20,165.00 20,370.00 20,629.00 21,368.00 21,665.00 162 1165
VR-300-(kW) 21,529.00 21,734.00 21,993.00 22,568.00 22,924.00 162 1350
VR-400-(kW) 26,390.00 26,595.00 26,854.00 27,450.00 27,712.00 162 1590
VR-500-(kW) 30,964.00 31,170.00 31,429.00 32,063.00 32,327.00 162 1700
VR-600-(kW) 34,971.00 35,178.00 35,437.00 36,009.00 36,263.00 216 2010
VR-800-(kW) 40,199.00 40,199.00 40,320.00 40,879.00 41,133.00 270 2450
VR-1000-(kW) 45,500.00 45,500.00 45,615.00 46,261.00 46,490.00 360 3160
VR-1250-(kW) 49,323.00 49,323.00 49,323.00 50,034.00 50,748.00 360 3792
VR-1500-(kW) 52,962.00 52,962.00 52,962.00 53,734.00 54,508.00 360 4550
VR-2000-(kW) 67,023.00 67,023.00 67,023.00 68,802.00 70,584.00 360 5460
VR-2500-(kW) 71,985.00 71,985.00 71,985.00 73,774.00 75,562.00 360 6553
Volts: 380V, 400V, 415V, 480V and 600V
Model
Number 45kW 54kW 60kW 72kW 90kW Max
kW Load
Approx.
Shpg. Wt.
VR-150-(kW) $20,422.00 $21,041.00 $21,644.00 $22,553.00 $23,100.00 90 650
VR-200-(kW) 21,973.00 22,591.00 23,195.00 24,020.00 24,615.00 162 750
VR-250-(kW) 23,086.00 23,705.00 24,309.00 25,123.00 25,667.00 162 1165
VR-300-(kW) 24,246.00 24,866.00 25,469.00 26,141.00 26,776.00 162 1350
VR-400-(kW) 28,781.00 29,401.00 30,003.00 30,620.00 31,139.00 162 1590
VR-500-(kW) 33,151.00 33,771.00 34,373.00 35,030.00 35,502.00 162 1700
VR-600-(kW) 37,126.00 37,746.00 38,349.00 38,882.00 39,378.00 216 2010
VR-800-(kW) 41,786.00 42,594.00 43,158.00 43,723.00 44,193.00 270 2450
VR-1000-(kW) 47,069.00 48,059.00 48,605.00 49,175.00 49,656.00 360 3160
VR-1250-(kW) 51,176.00 51,605.00 52,033.00 52,463.00 54,334.00 360 3792
VR-1500-(kW) 55,442.00 56,377.00 57,313.00 58,249.00 60,119.00 360 4550
VR-2000-(kW) 71,519.00 72,454.00 73,389.00 74,325.00 76,196.00 360 5460
VR-2500-(kW) 76,497.00 77,432.00 78,367.00 79,303.00 81,175.00 360 6553
Immersion Thermostats
VERTICAL ROUND MODELS
Three Year Limited Tank Warranty
Commercial multipliers (CSDs) are not applicable to
this product. Please call your local Bradford White
sales representative for pricing.
* Not subject to Commercial Stocking Program
* Not subject to Commercial Stocking Program
These Products Are Net And Not Subject To Performance Incentive Program.
28
Commercial Electric Models
Commercial Electric Models
Electric Brute™ Vertical Round
Volts: 380V, 400V, 415V, 480V and 600V
Model
Number 108kW 120kW 135kW 144kW 162kW Max
kW Load
Approx.
Shpg. Wt.
VR-150-(kW) — — — — — 90 650
VR-200-(kW) $26,406.00 $27,665.00 $27,876.00 $28,434.00 $29,284.00 162 750
VR-250-(kW) 27,497.00 27,644.00 27,853.00 28,400.00 30,064.00 162 1165
VR-300-(kW) 28,410.00 28,557.00 28,768.00 29,148.00 31,126.00 162 1350
VR-400-(kW) 32,486.00 32,633.00 32,844.00 33,399.00 35,387.00 162 1590
VR-500-(kW) 36,774.00 36,921.00 37,130.00 37,623.00 39,799.00 162 1700
VR-600-(kW) 40,710.00 40,856.00 41,067.00 41,449.00 43,677.00 216 2010
VR-800-(kW) 45,491.00 45,771.00 46,054.00 46,344.00 48,579.00 270 2450
VR-1000-(kW) 51,511.00 51,783.00 52,070.00 52,351.00 54,608.00 360 3160
VR-1250-(kW) 55,344.00 55,779.00 56,215.00 56,651.00 61,843.00 360 3792
VR-1500-(kW) 61,129.00 61,959.00 62,789.00 63,621.00 66,071.00 360 4550
VR-2000-(kW) 77,205.00 78,420.00 79,635.00 80,850.00 83,218.00 360 5460
VR-2500-(kW) 81,999.00 82,808.00 83,617.00 84,427.00 87,962.00 360 6553
Options
Alarm Bell ............................................................................. $279.00
BMS Contacts ...................................................................... $243.00
Manway ................................................................................ $485.00
Low Water Cut-off (LWCO) .................................................. $360.00
High or Low Water Pressure Switch .................................... $266.00
Pilot Lights and Switches ..................................................... $125.00
Safety Door Interlock ........................................................... $369.00
Seismic Bracing ................................................................... $233.00
Shunt Trip Disconnect ............................................. Consult Factory
Temperature Gauge ............................................................. $146.00
Pressure Gauge .................................................................... $146.00
Time Clock (24 hour) ............................................................ $340.00
Time Clock (7 day) ............................................................... $605.00
Double Vitraglas® Lining
(6-Year Limited Tank Warranty) .............................. Consult Factory
Solid State Step Controls:
1–4 steps .............................................................................. $704.00
5–8 steps ........................................................................... $1,698.00
9–12 steps ......................................................................... $2,746.00
Standard Equipment:
n ASME Construction
n 150 psi
n INCOLOY® heating elements
n Internal fusing (above 120 amps)
n Painted steel jacket
n Lifting Lug Access
n Magnesium anode rods
n Immersion Thermostats
n Magnetic contactors
n Manual reset high limit
n Hinged door with keyed lock
n ASME temperature & pressure relief valve
n Approved for 180ºF (82.2ºC) operation
Volts: 380V, 400V, 415V, 480V and 600V
Model
Number 180kW 216kW 252kW 270kW 288kW 324kW 360kW Max
kW Load
Approx.
Shpg. Wt.
VR-150-(kW) — — — — — — — 90 650
VR-200-(kW) — — — — — — — 162 750
VR-250-(kW) — — — — — — — 162 1165
VR-300-(kW) — — — — — — — 162 1350
VR-400-(kW) — — — — — — — 162 1590
VR-500-(kW) — — — — — — — 162 1700
VR-600-(kW)
$52,573.00 $55,112.00
— — — — — 216 2010
VR-800-(kW)
57,414.00 60,278.00 $64,076.00 $65,380.00
— — — 270 2450
VR-1000-(kW)
63,657.00 66,303.00 70,129.00 71,460.00 $72,887.00 $76,609.00 $79,230.00
360 3160
VR-1250-(kW)
67,035.00 70,185.00 74,390.00 75,903.00 77,417.00 80,744.00 85,037.00
360 3792
VR-1500-(kW)
68,522.00 74,829.00 77,845.00 79,781.00 81,717.00 86,530.00 91,008.00
360 4550
VR-2000-(kW)
85,588.00 90,906.00 95,166.00 96,796.00 98,427.00 102,606.00 107,292.00
360 5460
VR-2500-(kW)
91,498.00 95,883.00 99,649.00 101,450.00 103,250.00 107,585.00 112,896.00
360 6553
*May require additional control box * Not subject to Commercial Stocking Program*May require additional control box * Not subject to Commercial Stocking Program
* May require additional control box * Not subject to Commercial Stocking Program
These Products Are Net And Not Subject To Performance Incentive Program.
29
Commercial Indirect-Fired
Models/Storage
Commercial Indirect-Fired Models/Commercial Storage Tanks
Indirect Fired Models
Storage Tank Models
Immersed Aquastat
Note: These certified ratings were obtained with a heat source output of 245,000 BTU/Hr, a flow rate of 14.0 GPM, and a
180ºF boiler water supply temperature
* Not subject to Commercial Stocking Program
PowerStor Series
™ Single-Wall Indirect Models
2" Non-CFC Foam Insulation
Model
Number
Nominal
Capacity
(Gal.)
AHRI Rating
Continuous
Draw
@ 135°F Gal./Hr.
First Hour
Rating
@ 135°F
(Gal.)
Floor
to
Water
Conn.
Jacket
Dia.
Head Loss
@ 8GPM
Approx.
Shpg.
Wt. Lifetime
Limited
Tank Warranty
SW-65C-5
SW-80C-5
SW-120C-5
Floor
to
Top of
Heater
50"
591/4"
63"
633/4"
54
67
107
405
415
445
370
370
370
591/4"
59"
621/2"
60"
593/4"
631/4"
22"
24"
281/4"
1.63 ft.
1.63 ft.
1.63 ft.
273
300
422
$1,240.00
1,380.00
1,900.00
Model Floor to Top Floor to Hot Jacket Floor to Bottom Floor to Aquastat. Water
Approx.
Number of Heater Water Conn. Dia. Circ. Conn. & Top Circ. Conn. Conn. Size
Shpg. Wt.
M-3-ST-80R5
80 583⁄4" 593⁄4" 24" 91⁄4" 141⁄4" 2"(F&T) 192
M-3-ST-120R5
119 621⁄2" 631⁄2" 28" 91⁄2" 141⁄2" 2" (F,T & R) 312
Commercial Jacketed Storage Tanks - Non-ASME
2" Non-CFC Foam Insulation
Model Floor to Top Floor to Hot Jacket Floor to Bottom Floor to Aquastat. Water
Approx.
Number of Heater Water Conn. Dia. Circ. Conn. & Top Circ. Conn. Conn. Size
Shpg. Wt.
M-3-ST-80R5A
80 583⁄4" 593⁄4" 24" 91⁄4" 141⁄4" 2"(F&T) 278
M-3-ST-120R5A
119 621⁄2" 631⁄2" 28" 91⁄2" 141⁄2" 21⁄2"(F), 2”(R) 366
M-3-ST-200R5A
200 77" 78" 32" 111⁄4" 161⁄4" 21⁄2"(F&T) 633
Commercial Jacketed Storage Tanks - ASME
2" Non-CFC Foam Insulation
Hand Hole cleanout standard on M-3-ST-80R5.
F=Front water connections. R=Rear water connections.
T=Top Hot Outlet
Hand Hole cleanout standard.
F=Front water connections. R=Rear water connections.
T=Top Hot Outlet
Product Options Dash# Add
n 2" Connections in brass (Except M-3-ST-200R5A) .................................................... (-869) ..........
n 21⁄2" Connections in brass, M-3-ST-120R5A and M-3-ST-200R5A models only ........ (-870) ..........
n Hand Hole cleanout option, M-3-ST-120R5 model only ............................................ (-874) ..........
Limited 5 Year
Tank Warranty
Price
Limited 5 Year
Tank Warranty
Price
$1,250.00
1,385.00
$2,260.00
2,550.00
3,970.00
$
64.00
$
76.00
$
58.00
Nom.
Cap.
(Gal.)
Nom.
Cap.
(Gal.)
These Products Are Net And Not Subject To Performance Incentive Program.
30
Commercial Storage Tanks
Commercial Storage Tanks
Large Volume Storage Tank Models
These Products Are Net And Not Subject To Performance Incentive Program.
LARGE VOLUME JACKETED, UNJACKETED,
AND TOP COAT MODELS
WITH GALLON CAPACITIES RANGING FROM 193 TO 6,138 GALLONS.
Warranty Information
Product Selection & Crossover Information
Commercial Large Tank Models Limited Tank Warranty Limited Parts Warranty
Commercial Glass-lined large volume storage tanks
(Bare, Jacketed, and Top Coated models ......................................................................................... 5 Year 1 Year
Commercial Double Glass-lines large volume storage tanks
Tanks ((Bare, Jacketed, and Top Coated models) ........................................................................... 10 Year 1 Year
Vessel Dimensions
The Actual Capacity listed in this Schedule refer to the actual measurements of the storage actual vessel. They do not include added size
of jacketing, insulation, base rings, or cradles. The area inside the blue dashed lines in the drawing on the next page represent the Vessel
Dimensions. These dimensions can be useful when crossing over other brands of tanks. Please refer to the Specification Sheet for the overall
dimensions of the tank.
Nominal Capacity vs. Actual Capacity
The Nominal Capacity of a storage tank is the internal capacity of a cylinder based on the diameter and length of the tank. The Nominal
Capacity assumes the ends of the tank (also referred to as “heads”) are flat. The Nominal Capacity includes the blue and white shaded portions
of tank drawing on the next page.
The Actual Capacity of a storage tank factors in the rounded shape of the tank heads, and represents the tank’s true capacity. The white area
in the tank drawing on the next page shows the tank’s Actual Capacity.
31
Commercial Storage Tanks
Commercial Storage Tanks
These Products Are Net And Not Subject To Performance Incentive Program.
Storage Tank Model Number Structure
This is a Vertical 504-Gallon, Jacketed & Insulated, 150 PSI model
Pricing:
n To calculate the List Price of a tank with 150 psi Rating, or Top Coat or Double Vitraglas® Lining options,
select the appropriate List Price adder for the option, and add it to the List Price of the tank.
n Use the Tank Price Worksheet to calculate the total List Price and proper Model Designator.
Ordering
n Large Volume Storage Tanks must be ordered on a separate Purchase Order, and cannot be combined with other
Bradford White Products.
n When changing the quantity or locations of tank connections, clearly draw and label the location on the Tank
Dimension Template, and submit with the Purchase Order. An Engineering Drawing will be sent to the distributor for
signed customer approval. Custom Tank Orders are finalized and scheduled upon receipt of customer-approved Engineering Drawing to
Order Service.
n Custom tanks cannot be modified or cancelled after the customer approved Engineering Drawing has been returned
to Order Service.
n Custom tanks cannot be returned to Bradford White Corporation.
NV 504 JG
-5
Orientation
NV = Vertical
NH = Horizontal
Pressure
5A = 125 PSI
-5 = 150 PSI
Exterior Coating
N = Bare w/Red Oxide Primer
J = Jacketed & Insulated
T = Top Coat
Lining
G = Vitraglas®
(5-yr. Limited Warranty)
D = Double Vitraglas®
(10-yr. Limited Warranty)
E = Epoxy
(1-yr. Limited Warranty - Field Repairable)
S1 = 316L Unpassivated Stainless Steel
( 1-yr Limited Warranty)
S2 = 316L Passivated Stainless Steel
( 5-yr Limited Warranty)
S3 = 2205 Passivated Duplex Stainless Steel
( 15-yr Limited Warranty)
Options
HH = 4" x 6" Hand hole
MW = 12" x16" Manway
(Not Required on Models with Standard Manway)
-1 = Hydrojet HC®
SPC = Special Connections
Capacity
193 - 6,138 Gal.
32
Commercial Storage Tanks
Commercial Storage Tanks
These Products Are Net And Not Subject To Performance Incentive Program.
Manway
(Over 36" Dia.)
Manway
(Over 36" Dia.)
Always compare vessel dimensions and
capacities when crossing over a competitive
tank to ensure the best match!
Standard Features:
n Bare Tanks Feature Heavy gauge steel primed in red oxide color
n Water Connections: Heater Supply, Heater Return, ¾" NPT Aquastat, 1¼" NPT Relief Valve,
1" NPT Drain (Horizontal models include two additional 3" NPT fittings)
n 12" x 16" Manway is standard & included on all tanks with Vessel Diameter of 42" or larger.
n Base Ring: Standard on Vertical Models
n Vitraglas®-lined Carcon Steel tanks include 5-Year Limited Tank Warranty, & 1-Year Limited Warranty on Component Parts.
n Magnesium Anode Rods: provide additional corrosion resistance for trouble-free service
n Maximum Storage Temperature of Potable Water up to 180º F
n All tanks are Constructed and certified in accordance with ASME Sect. IV, Part HLW for 125 psi
Optional Equipment:
n Jacketed & Insulated Tanks: Features Steel Jacket with 2", R-12 Rated High Density Non-CFC Foam Insulation.
n Top Coated Tanks: Spayed-on rigid Top Coat polyurethane insulation, 2½", R-16 Rated layer of high
density foam insulation is formulated to withstand extreme weather and a full range of conditions
n Double Vitraglas® Lining: Adds an additional layer of protective coating for added corrosion
resistance. All Double Vitraglas® tanks include 10-Year Limited Tank Warranty & 1-Year Limited
Warranty on Component Parts.
n 150 psi Models constructed and certified in accordance with ASME Sect. IV, Part HLW for 150 psi.
n Optional Lift Lugs: Inc. 2 lugs on top of tank allow connection to rigging without removal of
jacket components.
n Hydrojet HC®: Stainless steel, dielectrically isolated recirculation tube minimizes turbulence, resulting in greater draw-down capacity
from the tank - Available Only With Standard 3" NPT Heater Supply Fitting.
n Additional / Custom Water Connections: (NPT or Flanged)
n Hand Hole Cleanout and Manway: 4" x 6" Hand Hole cleanout and 12" x 16" Manway opening allows removal of sediment and
inspection of interior surface (See “Standard Features” for availability).
33
Commercial Storage Tanks
Commercial Storage Tanks
Refer to page 53 for Optional Configurations and connections
nn Denotes Vitraglas® and Double Vitraglas®-lined tank sizes with standard 12" x 16" manway
Tank Style:
NV = Vertical
NH = Horizontal (for horizontal tanks change “NV” to “NH” and add saddles from options pricing)
† Tank Exterior:
N = Red oxide primer
T = Top coat (requires list price adder)
J = Jacketed & Insulated (use jacketed & insulated tank price)
Tank Lining:
G = Vitraglas®
D = Double Vitraglas® (requires list price adder)
E = Epoxy (contact factory for pricing)
S = Stainless Steel (contact factory for pricing)
S1 = 316L Unpassivated Stainless Steel (contact factory for pricing)
S2 = 316L Passivated Stainless Steel (contact factory for pricing)
S3 = 2205 Passivated Duplex Stainless Steel (contact factory for pricing)
Pressure Rating:
5A = 125 psi
-5 = 150 psi (requires list price adder)
1 Vessel Dimensions are for storage only, and do not include base rings, saddles, Top Coat or Jacket & Insulation.
See spec sheet for overall dimensions.
Commercial multipliers (CSDs) are not applicable to this product. Please call your local Bradford White sales representative for pricing.
Model
Number
Vessel
Dimensions
(in.) ¹
Tank
Capacity
(Gal.)
Price List Price Adders
Bare Vitraglas®
Lined Tanks
Insulated &
Top Coat
Vitraglas®
Lined Tanks
Jacketed &
Insulated
Vitraglas®
Lined Tanks
Double Vitraglas®
Lined Tanks
(Add to Tanklist Price)
150 psi
(Add to Tanklist Price)
NV193†G5A
30 X 67 193 $5,911.00 $7,453.00 $8,435.00
$1,215.00 $1,004.00
NV229†G5A
30 X 79 229 $6,134.00 $7,957.00 $8,854.00
NV260†G5A
30 X 89 260 $6,402.00 $8,462.00 $9,476.00
NV303†G5A
30 X 103 303 $6,712.00 $9,081.00 $10,700.00
NV340†G5A
30 X 115 340 $6,955.00 $9,564.00 $10,481.00
NV318†G5A
36 X 76 318 $7,394.00 $9,454.00 $11,093.00
$1,663.00 $1,004.00
NV344†G5A
36 X 82 344 $7,588.00 $9,854.00 $11,087.00
NV375†G5A
36 X 89 375 $7,938.00 $10,410.00 $11,557.00
NV397†G5A
36 X 94 397 $8,065.00 $10,640.00 $12,360.00
NV449†G5A
36 X 106 449 $8,432.00 $11,352.00 $13,013.00
NV502†G5A
36 X 118 502 $8,743.00 $12,003.00 $13,567.00
NV555†G5A
36 X 130 555 $9,107.00 $12,680.00 $14,217.00
NV432†G5A
46 X 80 432 $9,650.00 $12,208.00 $13,794.00
$2,187.00 $1,367.00
NV486†G5A
42 X 85 486 $9,926.00 $12,673.00 $14,232.00
NV504†G5A
42 X 88 504 $10,188.00 $13,038.00 $14,494.00
NV558†G5A
42 X 97 558 $10,459.00 $13,582.00 $15,784.00
NV630†G5A
42 X 109 630 $10,875.00 $14,449.00 $16,586.00
NV702†G5A
42 X 121 702 $11,235.00 $15,118.00 $17,237.00
NV774†G5A
42 X 133 774 $11,648.00 $15,812.00 $17,983.00
NV834†G5A
42 X 143 834 $12,026.00 $16,594.00 $18,694.00
$2,991.00 $1,367.00
NV572†G5A
48 X 77 572 $11,965.00 $14,815.00 $16,784.00
NV658†G5A
42 X 88 658 $12,668.00 $15,929.00 $18,295.00
NV752†G5A
48 X 100 752 $13,659.00 $17,336.00 $20,207.00
NV846†G5A
48 X 112 846 $14,469.00 $18,591.00 $20,503.00
NV940†G5A
48 X 124 940 $15,773.00 $20,308.00 $24,049.00
NV1128†G5A
48 X 145 1,128 $17,456.00 $22,746.00 $24,080.00
These Products Are Net And Not Subject To Performance Incentive Program.
34
Commercial Storage Tanks
Commercial Storage Tanks
Commercial multipliers (CSDs) are not applicable to this product. Please call your local Bradford White sales representative for pricing.
Model
Number
Vessel
Dimensions
(in.) ¹
Tank
Capacity
(Gal.)
Price List Price Adders
Bare Vitraglas®
Lined Tanks
Insulated &
Top Coat
Vitraglas®
Lined Tanks
Jacketed &
Insulated
Vitraglas®
Lined Tanks
Double Vitraglas®
Lined Tanks
(Add to Tanklist Price)
150 psi
(Add to Tanklist Price)
NV1306†G5A
48 X 174 1,306 $19,272.00 $25,544.00 N/A
$5,562.00 $2,453.00
NV981†G5A
54 X 105 981 $20,704.00 $24,958.00 N/A
NV1119†G5A
54 X 119 1,119 $21,803.00 $26,538.00 $35,041.00
NV1219†G5A
54 X 129 1,219 $22,672.00 $27,890.00 N/A
NV1327†G5A
54 X 140 1,327 $24,807.00 $30,591.00 N/A
NV1457†G5A
54 X 153 1,457 $25,367.00 $31,577.00 N/A
NV1635†G5A
54 X 171 1,635 $26,920.00 $33,873.00 N/A
NV1814†G5A
54 X 189 1,814 $28,120.00 $35,774.00 N/A
NV1395†G5A
60 X 120 1,395 $28,950.00 $34,338.00 $44,864.00
$6,897.00 $2,593.00
NV1689†G5A
60 X 144 1,689 $31,929.00 $38,415.00 $48,438.00
NV1983†G5A
60 X 174 1,983 $34,592.00 $42,418.00 N/A
NV2165†G5A
60 X 183 2,165 $37,082.00 $45,481.00 N/A
NV2276†G5A
60 X 192 2,276 $37,868.00 $46,516.00 N/A
NV2570†G5A
60 X 216 2,570 $40,766.00 $50,477.00 N/A
NV1761†G5A
72 X 106 1,761 $31,269.00 $37,165.00 N/A
$9,567.00 Contact
Factory for Pricing
NV2061†G5A
72X 123 2,061 $33,939.00 $40,725.00 N/A
NV2115†G5A
72 X 126 2,115 $34,396.00 $41,189.00 N/A
NV2256†G5A
72 X 134 2,256 $34,701.00 $41,932.00 N/A
NV2538†G5A
72 X 150 2,538 $38,011.00 $46,104.00 N/A
NV2765†G5A
72 X 163 2,765 $39,919.00 $48,617.00 N/A
NV2959†G5A
72 X 174 2,959 $41,487.00 $50,890.00 N/A
NV3382†G5A
72 X 198 3,382 $45,966.00 $56,642.00 N/A
NV3805†G5A
72 X 222 3,805 $49,117.00 $61,088.00 N/A
NV4404†G5A
72 X 256 4,404 $53,703.00 $67,498.00 N/A
NV2901†G5A
84 X 127 2,901 $47,444.00 $55,565.00 N/A
$11,346.00 Contact
Factory for Pricing
NV3308†G5A
84 X 144 3,308 $52,505.00 $61,071.00 N/A
NV3884†G5A
84 X 168 3,884 $57,622.00 $67,695.00 N/A
NV4459†G5A
84 X 192 4,459 $61,182.00 $72,751.00 N/A
NV5038†G5A
84 X 216 5,038 $66,460.00 $79,420.00 N/A
NV6138†G5A
84 X 262 6,138 $74,960.00 $90,655.00 N/A
Refer to page 53 for Optional Configurations and connections
nn Denotes Vitraglas® and Double Vitraglas®-lined tank sizes with standard 12" x 16" manway
Tank Style:
NV = Vertical
NH = Horizontal (for horizontal tanks change “NV” to “NH” and add saddles from options pricing)
† Tank Exterior:
N = Red oxide primer
T = Top coat (requires list price adder)
J = Jacketed & Insulated (use jacketed & insulated tank price)
Tank Lining:
G = Vitraglas®
D = Double Vitraglas® (requires list price adder)
E = Epoxy (contact factory for pricing)
S = Stainless Steel (contact factory for pricing)
S1 = 316L Unpassivated Stainless Steel (contact factory for pricing)
S2 = 316L Passivated Stainless Steel (contact factory for pricing)
S3 = 2205 Passivated Duplex Stainless Steel (contact factory for pricing)
Pressure Rating:
5A = 125 psi
-5 = 150 psi (requires list price adder)
1 Vessel Dimensions are for storage only, and do not include base rings, saddles, Top Coat or Jacket & Insulation.
See spec sheet for overall dimensions.
These Products Are Net And Not Subject To Performance Incentive Program.
35
Commercial Storage Tanks
Commercial Storage Tanks
Tank Options: Add Designator to Tank Model Number to Order
Optional: Optional Fittings, Flanges, & Accessories
Description Designator List Price
Jacketed / Top Coat Tanks Bare Tanks
Hand Hole Clean-out (4" x 6") “HH” $524.00 $394.00
12" x 16" Manway¹ “MW” $1,102.00 $767.00
Hydrojet HC®—Stainless steel, dielectrically
isolated recirculation tube (Available only with
standard 3"NPT Heater Supply connection)
“-1” $356.00 $356.00
Tank Saddles - Required for Horizontal Tanks
(Includes Two 9' welded Saddles) Use “NH” Designator in Model Number
Vessel Diameter
30" & 36" $522.00
42", 48", & 54" $1,270.00
60", 72", 84" $2,313.00
List Price
Jacketed / Top Coat Tanks Bare Tanks
Seismic Clips
Can be added when Seismic Certification of the tanks is required.
Seismic Clips vary by the size and configuration of
tank. To ensure certification for the proper seismic zone, please
include the address where the tank is to be installed on the Custom
Tank Template.
$400.00 $400.00
Extended Lift Lugs
Protrude through the top jacket panel of Jacketed & Insulated
storage tanks, providing a convenient lift point.
Extended Lift Lugs are optional on Jacketed & Insulated tanks, and
standard on Bare and Top Coat tanks. List Price Adder includes
two Extended Lift Lugs per tank.
$162.00 Included
Stainless Steel Fittings
Standard NPT tank fittings constructed of stainless steel. Consult
Factory for additional or upsized Stainless Steel Fittings.
$1,863.00
¹Manway is standard & included in List Price on 42" through 72" Diameter vessels
The Hydrojet HC® Recirculation Tube threads into 3" NPT tank fittings, and diffuses the flow of water entering the tank.
The unique design minimizes turbulence, resulting in greater draw-down capacity from the tank.
Order as separate line items on PO
Use Custom Tank Template to specify type, quantity and location of optional Fittings, Flanges, & Connections.
Optional NPT Fittings List Price
Size / Type
List Price
Jacketed / Top Coat
Tanks Bare Tanks
¾" NPT $146.00 $113.00
1" NPT $151.00 $119.00
1¼" NPT $157.00 $124.00
1½" NPT $221.00 $157.00
2" NPT $232.00 $162.00
2½" NPT $254.00 $189.00
3" NPT $286.00 $221.00
4" NPT $475.00 $421.00
OPTIONAL NPT
FITTINGS
OPTIONAL
FLANGED
CONNECTIONS
Optional Flanged Connections
Size / Type
List Price
Jacketed / Top Coat
Tanks Bare Tanks
4" Flange $427.00 $324.00
6" Flange $545.00 $454.00
8" Flange $886.00 $605.00
10" Flange $1,388.00 $1,026.00
12" Flange $2,225.00 $1,361.00
14" Flange $1,102.00 $1,674.00
These Products Are Net And Not Subject To Performance Incentive Program.
At Bradford White, our business is being there for your business. Our job is to
help you serve the needs of contractors, installers and specifying engineers.
And that’s not just talk – we stand behind you every day.
When you sell Bradford White, you can always count on getting:
Built to be the BestTM
©2017, Bradford White Corporation. All rights reserved.
Built to be the BestTM
WE’RE HERE
FOR THE PRO.
And We Mean It.
Visit bwforthepro.com
to learn more!
Built to be the Best™ water
heaters, boilers and tanks that deliver
top quality, high performance and
unmatched reliability.
Unparalleled Tech Sales Support,
so you have all the resources you
need to make sure the needs of your
customers are met.
Marketing Materials to help you
communicate with your professional
customers and prospects more
e ectively than ever before.
Our Exclusive For The Pro®
Website – full of tools to help you
build your business and ensure your
success.
At Bradford White, our business is being there for your business. Our job is to
help you serve the needs of contractors, installers and specifying engineers.
And that’s not just talk – we stand behind you every day.
When you sell Bradford White, you can always count on getting:
Built to be the BestTM
©2017, Bradford White Corporation. All rights reserved.
Built to be the BestTM
WE’RE HERE
FOR THE PRO.
And We Mean It.
Visit bwforthepro.com
to learn more!
Built to be the Best™ water
heaters, boilers and tanks that deliver
top quality, high performance and
unmatched reliability.
Unparalleled Tech Sales Support,
so you have all the resources you
need to make sure the needs of your
customers are met.
Marketing Materials to help you
communicate with your professional
customers and prospects more
eectively than ever before.
Our Exclusive For The Pro®
Website – full of tools to help you
build your business and ensure your
success.
for the pro ad 8.5x11_no_solar.indd 1 11/16/18 9:31 AM
www.bradfordwhite.com
CPB-030419
©2019, Bradford White Corporation. All rights reserved.