NAECA

Compliant

Residential Power Vent
Gas Water Heater

Photo is of
RG2PV50H6N
FEATURING:

The TTW® Models Feature:
■ ENERGY STAR® Qualified—Some models qualify for the September 1, 2010
minimum ENERGY STAR® EF requirement, as well as most utility rebate programs.
■ Bradford White ICON System™—Intelligent gas control with spark to pilot ignition
system eliminates the constant burning pilot. This results in savings of pilot gas during
standby periods (120 V.A.C.).
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Delivery
ratings and tighter temperature differentials.
-- Advanced Temperature Control System—Microprocessor constantly monitors and
controls burner operation to maintain consistent and accurate water temperature levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer during
start-up and provides ten different diagnostic codes to assist in troubleshooting.
■ Power Vented Water Heater—Designed for installations where atmospheric units
cannot be used. Exhaust gases are vented under positive pressure directly out of the
building through the roof or the wall.
■ Powerful Blower Motor—Our significantly quiet design has greater resistance to
outside winds and the power to vent in many difficult venting situations.
-- Ten Foot Power Cord—Included (120 VAC).
■ Horizontal and Vertical Venting—PVC, ABS or CPVC (Maximum equivalent vent
length on reverse side).
■ Advanced ScreenLok® Technology Flame Arrestor Design—Flame arrestor is
designed to prevent ignition of flammable vapor outside of the water heater (excluding
RG1PV55H6N & RG2PV75H6N).
■ Flammable Vapor Sensor—Electronic sensor prevents burner operation if flammable
vapors are detected. The sensor will also prevent operation if there is ongoing
flammable vapor burn inside the combustion chamber (excluding RG1PV55H6N &
RG2PV75H6N).
■ Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is
required under normal conditions (excluding RG1PV55H6N & RG2PV75H6N).
■ Sight Window—Offers a view into the combustion chamber to observe the operation
of the pilot and burner.
■ Factory-Installed Hydrojet® Total Performance System—Cold water inlet sediment
reducing device helps prevent sediment build-up in tank. This increases first hour
delivery, while minimizing temperature build-up at top of tank.
■ Vitraglas® Lining—Bradford White tanks are lined with an exclusively engineered
enamel formula that provides superior tank protection from the highly corrosive effects
of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a
temperature of over 1600°F (871ºC).
■ Non-CFC Foam Insulation—Covers the sides and top, reducing the amount of heat
loss. This results in less energy consumption, improved operation efficiencies, and
jacket rigidity.
■ Water Connections—3/4" NPT factory-installed true dielectric fittings.
■ 3/4" NPT Side Connections—(RG2PV50H6N, RG1PV55H6N, and RG2PV75H6N
only).
■ Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat
loss in piping and eliminates the potential for noise generation.
■ Protective Magnesium Rod—(RG1PV55H6N has 2).
■ T&P Relief Valve—Installed.
■ Thermostatic Mixing Valve (ASSE Approved)—Included (RG1PV55H6N only).
■ Low Restriction Brass Drain Valve—Durable tamper-proof design.

6 or 10-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526;
6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984;
8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS:
2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System®, ScreenLok®, TTW®, Vitraglas® and Hydrojet® are registered
trademarks of Bradford White® Corporation.
1260-A-0715

Residential Power Vent Gas Water Heater
TTW® Models

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery Efficiency

NATURAL GAS AND LIQUID PROPANE GAS
Model
Number

Capacity

Recovery at
90°F Rise*

Model
Number

Nat.
LP 1st Hour
Nat. Nat. LP LP
U.S. Imp. BTU/Hr. BTU/Hr. Rating Energy U.S. Imp. U.S. Imp.
Gal. Gal. Input
Input
(Gal.) Factor GPH GPH GPH GPH
RG1PV40S6N
RG1PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N

40
50
40
50
48
55
75

33
42
33
42
42
46
62

40,000
40,000
40,000
40,000
65,000
78,000
76,000

38,000
38,000
40,000
40,000
58,000
78,000
75,500

Model
Number

A
Floor to
Vent
Conn.
in.

B
Jacket
Dia.
in.

RG1PV40S6N
RG1PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N

57 5/16
58 1/4
66 7/8
66 7/8
66 1/8
64 3/16
69 7/16

20
22
20
22
22
22
26

Model
Number

A
Floor to
Vent
Conn.
mm.

B
Jacket
Dia.
mm.

RG1PV40S6N
RG1PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N

1456
1480
1699
1699
1680
1630
1764

508
559
508
559
559
559
660

72
86
72
86
112
N/A
N/A

C
Vent
Size

0.66
0.65
0.70
0.70
0.70
N/A
N/A

36
36
36
36
58
70
68

43
43
43
43
70
84
82

41
41
43
43
62
84
81

34
34
36
36
52
70
67

RG1PV40S6N
RG1PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N

Capacity

Recovery at
50°C Rise*

Liters

Nat.
kW
Input

LP
kW
Input

151
189
151
189
182
208
284

11.7
11.7
11.7
11.7
19.1
22.9
22.3

11.1
11.1
11.7
11.7
17.0
22.9
22.1

E
Floor to
Gas
Conn.
in.

F
Floor to
Top of
Heater
in.

H
C/L
of Water
Conn.
in.

J
Floor to
Water
Conn.
in.

K
Depth

in.

D
Floor to
T&P
Conn.
in.

2 or 3
2 or 3
2 or 3
2 or 3
3 or 4
3 or 4
3 or 4

40
40 5/8
50
50
50 1/8
47 15/16
51 1/2

11 3/4
11 3/4
113/4
113/4
11 3/4
111/2
13 1/2

47 1/2
48 1/4
56 3/4
56 3/4
56 3/8
54 5/8
59 1/2

8
8
8
8
11
8
11

49
50 1/2
58
58
57 3/4
56
60 3/4

C
Vent
Size
mm.

D
Floor to
T&P
Conn.
mm.

E
Floor to
Gas
Conn.
mm.

F
Floor to
Top of
Heater
mm.

H
C/L
of Water
Conn.
mm.

51or76
51or76
51or76
51or76
76 or 102
76 or 102
76 or 102

1016
1032
1270
1270
1273
1218
1308

298
298
298
298
298
279
343

1207
1226
1441
1441
1432
1388
1511

203
203
203
203
279
203
279

1st Hour
Rating Energy
(Liters) Factor
273
326
273
326
424
N/A
N/A

0.66
0.65
0.70
0.70
0.70
N/A
N/A

Nat.
Liters/
Hour

LP
Liters/
Hour

163
163
163
163
265
318
310

155
155
163
163
235
317
307

M
Floor to
Space Heating
Outlet
in.

Approx.
Shipping
Weight

in.

L
Floor to
Space Heating
Inlet
in.

27 7/8
26 3/4
24 1/2
26 1/2
26 3/4
26 1/2
30 1/4

N/A
N/A
N/A
N/A
13 1/2
133/8
13 3/8

N/A
N/A
N/A
N/A
50 1/8
47 15/16
511/2

140
166
146
173
187
219
260

J
Floor to
Water
Conn.
mm.

K
Depth

M
Floor to
Space Heating
Outlet
mm.

Approx.
Shipping
Weight

mm.

L
Floor to
Space Heating
Inlet
mm.

1245
1283
1473
1473
1467
1422
1543

708
679
622
673
679
673
768

N/A
N/A
N/A
N/A
343
340
340

N/A
N/A
N/A
N/A
1273
1218
1308

64
75
66
78
85
99
118

lbs.

kg.

Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "N" to "X". For 10 year models, change suffix
from “6” to “10”. *Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC 60HZ 3.1 Amperes.
Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
C
★ = ENERGY STAR® Qualified.

B

K
H

RG1PV40S6N
RG1PV50S6N
RG2PV40T6N
RG2PV50T6N
Max. Equivalent Length
Min. Equivalent Length
Number
1
of
2
90° Elbows
3

2"
Vent Pipe
†50 ft.
7 ft.
45 ft.
40 ft.
35 ft.

3"
Vent Pipe
†120 ft.
15 ft.
115 ft.
110 ft.
105 ft.

RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
Max. Equivalent Length
Min. Equivalent Length
Number
1
of
2
90° Elbows
3

3"
Vent Pipe
†50 ft.
7 ft.
45 ft.
40 ft.
35 ft.

4"
Vent Pipe
†180 ft.
15 ft.
175 ft.
170 ft.
165 ft.

Subtract 5ft. for each additional 90° elbow
†For high altitude installations, consult the installation instructions.

J
A
F
D&M

L

E

General: All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4"
NPT (19mm), all gas connections are 1⁄2" (13mm). All models design-certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and/or 10.3 and
peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this
system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Ambler, PA

Sales 800-523-2931 ● Fax 215-641-1670 / Technical Support 800-334-3393 ● Fax 269-795-1089 ● Warranty 800-531-2111 ● Fax 269-795-1089
International: Telephone 215-641-9400 ● Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 ● Fax 905-238-0105 / www.bradfordwhite.com

1260-A-0715

©2015, Bradford White Corporation. All rights reserved.

Printed in U.S.A.



Navigation menu