Open PDF In Browser | View PDF |
2015 NAECA Compliant Residential Power Vent Gas Water Heater Photo is of RG2PV50H6N FEATURING: The TTW® Models Feature: ■ ENERGY STAR® Qualified—Some models qualify for the September 1, 2010 minimum ENERGY STAR® EF requirement, as well as most utility rebate programs. ■ Bradford White ICON System™—Intelligent gas control with spark to pilot ignition system eliminates the constant burning pilot. This results in savings of pilot gas during standby periods (120 V.A.C.). -- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Delivery ratings and tighter temperature differentials. -- Advanced Temperature Control System—Microprocessor constantly monitors and controls burner operation to maintain consistent and accurate water temperature levels. -- Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up and provides ten different diagnostic codes to assist in troubleshooting. ■ Power Vented Water Heater—Designed for installations where atmospheric units cannot be used. Exhaust gases are vented under positive pressure directly out of the building through the roof or the wall. ■ Powerful Blower Motor—Our significantly quiet design has greater resistance to outside winds and the power to vent in many difficult venting situations. -- Ten Foot Power Cord—Included (120 VAC). ■ Horizontal and Vertical Venting—PVC, ABS or CPVC (Maximum equivalent vent length on reverse side). ■ Advanced ScreenLok® Technology Flame Arrestor Design—Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater (excluding RG1PV55H6N & RG2PV75H6N). ■ Flammable Vapor Sensor—Electronic sensor prevents burner operation if flammable vapors are detected. The sensor will also prevent operation if there is ongoing flammable vapor burn inside the combustion chamber (excluding RG1PV55H6N & RG2PV75H6N). ■ Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is required under normal conditions (excluding RG1PV55H6N & RG2PV75H6N). ■ Sight Window—Offers a view into the combustion chamber to observe the operation of the pilot and burner. ■ Factory-Installed Hydrojet® Total Performance System—Cold water inlet sediment reducing device helps prevent sediment build-up in tank. This increases first hour delivery, while minimizing temperature build-up at top of tank. ■ Vitraglas® Lining—Bradford White tanks are lined with an exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a temperature of over 1600°F (871ºC). ■ Non-CFC Foam Insulation—Covers the sides and top, reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies, and jacket rigidity. ■ Water Connections—3/4" NPT factory-installed true dielectric fittings. ■ 3/4" NPT Side Connections—(RG2PV50H6N, RG1PV55H6N, and RG2PV75H6N only). ■ Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss in piping and eliminates the potential for noise generation. ■ Protective Magnesium Rod—(RG1PV55H6N has 2). ■ T&P Relief Valve—Installed. ■ Thermostatic Mixing Valve (ASSE Approved)—Included (RG1PV55H6N only). ■ Low Restriction Brass Drain Valve—Durable tamper-proof design. 6 or 10-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System®, ScreenLok®, TTW®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation. 1260-A-0715 Residential Power Vent Gas Water Heater TTW® Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency NATURAL GAS AND LIQUID PROPANE GAS Model Number Capacity Recovery at 90°F Rise* Model Number Nat. LP 1st Hour Nat. Nat. LP LP U.S. Imp. BTU/Hr. BTU/Hr. Rating Energy U.S. Imp. U.S. Imp. Gal. Gal. Input Input (Gal.) Factor GPH GPH GPH GPH RG1PV40S6N RG1PV50S6N ★ RG2PV40T6N ★ RG2PV50T6N ★ RG2PV50H6N RG1PV55H6N RG2PV75H6N 40 50 40 50 48 55 75 33 42 33 42 42 46 62 40,000 40,000 40,000 40,000 65,000 78,000 76,000 38,000 38,000 40,000 40,000 58,000 78,000 75,500 Model Number A Floor to Vent Conn. in. B Jacket Dia. in. RG1PV40S6N RG1PV50S6N ★ RG2PV40T6N ★ RG2PV50T6N ★ RG2PV50H6N RG1PV55H6N RG2PV75H6N 57 5/16 58 1/4 66 7/8 66 7/8 66 1/8 64 3/16 69 7/16 20 22 20 22 22 22 26 Model Number A Floor to Vent Conn. mm. B Jacket Dia. mm. RG1PV40S6N RG1PV50S6N ★ RG2PV40T6N ★ RG2PV50T6N ★ RG2PV50H6N RG1PV55H6N RG2PV75H6N 1456 1480 1699 1699 1680 1630 1764 508 559 508 559 559 559 660 72 86 72 86 112 N/A N/A C Vent Size 0.66 0.65 0.70 0.70 0.70 N/A N/A 36 36 36 36 58 70 68 43 43 43 43 70 84 82 41 41 43 43 62 84 81 34 34 36 36 52 70 67 RG1PV40S6N RG1PV50S6N ★ RG2PV40T6N ★ RG2PV50T6N ★ RG2PV50H6N RG1PV55H6N RG2PV75H6N Capacity Recovery at 50°C Rise* Liters Nat. kW Input LP kW Input 151 189 151 189 182 208 284 11.7 11.7 11.7 11.7 19.1 22.9 22.3 11.1 11.1 11.7 11.7 17.0 22.9 22.1 E Floor to Gas Conn. in. F Floor to Top of Heater in. H C/L of Water Conn. in. J Floor to Water Conn. in. K Depth in. D Floor to T&P Conn. in. 2 or 3 2 or 3 2 or 3 2 or 3 3 or 4 3 or 4 3 or 4 40 40 5/8 50 50 50 1/8 47 15/16 51 1/2 11 3/4 11 3/4 113/4 113/4 11 3/4 111/2 13 1/2 47 1/2 48 1/4 56 3/4 56 3/4 56 3/8 54 5/8 59 1/2 8 8 8 8 11 8 11 49 50 1/2 58 58 57 3/4 56 60 3/4 C Vent Size mm. D Floor to T&P Conn. mm. E Floor to Gas Conn. mm. F Floor to Top of Heater mm. H C/L of Water Conn. mm. 51or76 51or76 51or76 51or76 76 or 102 76 or 102 76 or 102 1016 1032 1270 1270 1273 1218 1308 298 298 298 298 298 279 343 1207 1226 1441 1441 1432 1388 1511 203 203 203 203 279 203 279 1st Hour Rating Energy (Liters) Factor 273 326 273 326 424 N/A N/A 0.66 0.65 0.70 0.70 0.70 N/A N/A Nat. Liters/ Hour LP Liters/ Hour 163 163 163 163 265 318 310 155 155 163 163 235 317 307 M Floor to Space Heating Outlet in. Approx. Shipping Weight in. L Floor to Space Heating Inlet in. 27 7/8 26 3/4 24 1/2 26 1/2 26 3/4 26 1/2 30 1/4 N/A N/A N/A N/A 13 1/2 133/8 13 3/8 N/A N/A N/A N/A 50 1/8 47 15/16 511/2 140 166 146 173 187 219 260 J Floor to Water Conn. mm. K Depth M Floor to Space Heating Outlet mm. Approx. Shipping Weight mm. L Floor to Space Heating Inlet mm. 1245 1283 1473 1473 1467 1422 1543 708 679 622 673 679 673 768 N/A N/A N/A N/A 343 340 340 N/A N/A N/A N/A 1273 1218 1308 64 75 66 78 85 99 118 lbs. kg. Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "N" to "X". For 10 year models, change suffix from “6” to “10”. *Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC 60HZ 3.1 Amperes. Energy Factor and First Hour Rating is based on the latest AHRI directory listings. C ★ = ENERGY STAR® Qualified. B K H RG1PV40S6N RG1PV50S6N RG2PV40T6N RG2PV50T6N Max. Equivalent Length Min. Equivalent Length Number 1 of 2 90° Elbows 3 2" Vent Pipe †50 ft. 7 ft. 45 ft. 40 ft. 35 ft. 3" Vent Pipe †120 ft. 15 ft. 115 ft. 110 ft. 105 ft. RG2PV50H6N RG1PV55H6N RG2PV75H6N Max. Equivalent Length Min. Equivalent Length Number 1 of 2 90° Elbows 3 3" Vent Pipe †50 ft. 7 ft. 45 ft. 40 ft. 35 ft. 4" Vent Pipe †180 ft. 15 ft. 175 ft. 170 ft. 165 ft. Subtract 5ft. for each additional 90° elbow †For high altitude installations, consult the installation instructions. J A F D&M L E General: All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4" NPT (19mm), all gas connections are 1⁄2" (13mm). All models design-certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and/or 10.3 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative. Ambler, PA Sales 800-523-2931 ● Fax 215-641-1670 / Technical Support 800-334-3393 ● Fax 269-795-1089 ● Warranty 800-531-2111 ● Fax 269-795-1089 International: Telephone 215-641-9400 ● Telefax 215-641-9750 / www.bradfordwhite.com Sales / Technical Support 866-690-0961 / 905-238-0100 ● Fax 905-238-0105 / www.bradfordwhite.com 1260-A-0715 ©2015, Bradford White Corporation. All rights reserved. Printed in U.S.A.