Braeburn Systems 7220 thermostat User Manual

Braeburn Systems LLC thermostat

a href="https://usermanual.wiki/Braeburn-Systems" itemprop="url"> Braeburn Systems >

User manual

Universal Wireless Thermostat Kit• Possible electric shock or damage to equipment can occur.• Disconnect power before beginning installation.CautionThis thermostat requires 2 properly installed “AA” Alkaline batteries for proper operation. When connecting optional 24 Volt AC power the batteries may be installed as a backup.For use only as described in this manual. Any other use will void warranty.7500 Up to 3 Heat / 2 Cool Heat Pump  Up to 2 Heat / 2 Cool Conventional with wireless Humidity Control*WarningFor installation by experienced service technicians only.®      KIT INCLUDES: Wireless thermostat (7220), control module (7325) and return air plenum sensor.    This thermostat is compatible with:  • Singlestageheat/coolconventionalandheatpumpsystems  • Conventionalsystemsupto2stagesofheatingand2stagesofcooling  • Heatpumpsystemsupto3stagesofheatingand2stagesofcooling  • 2or3wirehydroniczonesystems   Electrical and control specifications:  • ElectricalRating:24VoltAC  • 1ampmaximumloadperterminal  • ACPower:18–30VoltsAC  • DCPower:3.0VoltDC(2“AA”AlkalineBatteriesIncluded)  • ControlRange:45°–90°F(7°–32°C)  • TemperatureAccuracy:+/-1°F(+/-.5°C)  • OutdoorTemperatureDisplayRange:-40°-120°F(-40°-49°C)   Terminations  Thermostat:R,C(optional24VACpowerterminals)  ControlModule:Rh,Rc,G,W1/E,W2/AUX,Y1,Y2,O/B/V3,L,C,P1,P2,S1,S21Specifications7500-100-03Installer Guide*WirelessHumidityControlrequiresaccessorymodel7330.1 Specifications    2 Installation and Wireless Setup   3 Quick Reference    4 Installer Settings   5 Wireless Remote Sensors   6 System TestingTM
Installer Guide                                                                   22Installation and Wireless Setup    Install and Wire the Control Module1Wiring Terminations for Control Module  Terminal  Conventional Systems  Heat Pump Systems  Rh 24VoltACHeatingTransformer 24VoltACTransformer  Rc 24VoltACCoolingTransformer NotUsed  G SystemFanRelay SystemFanRelay  W1/E (W1)1stStageHeatRelay (E)EmergencyHeatRelay    W2/AUX (W2)2ndStageHeatRelay (AUX)AuxiliaryHeatRelay     O/B/V3 (V3)ZoneValvePowerClose (O)CoolActiveReversingValve   (HydronicSystemsOnly) (B)HeatActiveReversingValve  Y1 1stStageCoolingRelay 1stStageCompressorRelay  Y2 2ndStageCoolingRelay 2ndStageCompressorRelay  L NotUsed  SystemFaultIndicator  C 24VoltACTransformerCommon 24VoltACTransformerCommon  S1 OptionalWiredRemoteSensor OptionalWiredRemoteSensor  S2 (IndoororOutdoor) (IndoororOutdoor)  P1 RequiredReturnAirPlenum RequiredReturnAirPlenum  P2 Sensor(mustbeinstalled) Sensor(mustbeinstalled)WarningDisconnect power before beginning installation.Control Module LocationInstallthecontrolmoduleonawallnearHVACequipment orontheHVACequipment.•Removethecoverofthecontrolmodule.•Mountthecontrolmoduleusingthetwomountingholesandtheappropriatetypeofscrewsfortheapplication.Install Return Air Sensor (required)TheReturnAirSensormaintainsdefaulttemperaturecontrolifwirelesscommunicationislost.•InstalltheReturnAirSensoratleast12inchesupstream ofanyhumidicationorventilationequipment.•ConnecttheReturnAirSensortotheP1andP2  terminals on the control module.•Forhydronicapplications,mountsensorinanareathat maintainslivingspacetemperature.Donotmount onthesupplypipes. WiringPunchoutMountingHoleMountingHoleWiringPunchout  Heat Only  Set System Type to 11CONV Rh 24VoltACPower(heatingtransformer)[note 1] W1 HeatRelay G FanRelay[note 3] C 24VoltACTransformerCommon 1 HEAT / 1 COOL Single or Dual Transformer   Set System Type to 11CONV Rh 24VoltACPower(heatingtransformer)[note 1] Rc 24VoltACPower(coolingtransformer)[note 1] W1 HeatRelay Y1 CompressorRelay G FanRelay C 24VoltACTransformerCommon[note 2] 2 HEAT / 2 COOL Single or Dual transformer  Set System Type to 22CONV Rh 24VoltACPower(heatingtransformer)[note 1] Rc 24VoltACPower(coolingtransformer)[note 1] W1 HeatRelayStage1 W2 HeatRelayStage2 Y1 CompressorRelayStage1 Y2 CompressorRelayStage2 [note 3] G FanRelay C 24VoltACTransformerCommon[note 2]ConnectButton Rc/RhTerminalJumper (J3)
Download:
Mirror Download [FCC.gov]
Document ID2575028
Application IDjCuxNsWaYMLyk4bblhEiww==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize294.72kB (3684037 bits)
Date Submitted2015-04-03 00:00:00
Date Available2015-04-03 00:00:00
Creation Date2015-03-23 19:31:59
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2015-04-01 19:17:11
Document TitleUser manual
Document CreatorAdobe InDesign CS6 (Macintosh)
FCC ID Filing: 2ADX6-7220

Navigation menu