P1000i/P2000i QUICK START GUIDE

This Quick Start Guide is not a substitute for reading the Operator’s Manual.
To reduce the risk of injury or death, user must read and understand Operator’s Manual before using this product.

IMPORTANT
Do not connect to a building’s
electrical system unless the generator
and transfer switch have been verified
by a qualified electrician. The
connection must isolate the generator
power from utility power and must
comply with all applicable laws and
electrical codes.

First Time Starting (Cont.)
DANGER

Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide.
This is a poison you cannot see or smell.

NEVER use inside a home
or garage. EVEN IF doors
and windows are open.

7.

Once the engine is running,
slowly move choke lever left
to the RUN position.

8.

After a 2-3 minute warm up,
Push the SMART THROTTLE
switch to ON.

Troubleshooting
PROBLEM

- Engine switch is off.
- No fuel.
- Stale fuel or water
in fuel.
- Engine oil level is low.
- Spark plug faulty, fouled
or improperly gapped.
- Choke lever is in
RUN position.
- Engine stored without
treating or draining
fuel.
- Refueled with bad
fuel.
- Dirty fuel filter.

- Turn engine switch to ON.
- Fill fuel tank.
- Drain entire fuel system
and refill with fresh fuel.
- Engine is equipped with
Low Oil Shutoff. If the
engine oil level is
low, the unit will not start.
Check engine oil
level and fill if necessary.
- Replace spark plug.
- Move choke lever to
START position.
- Drain fuel and carburetor.
Refuel with fresh
fuel.
- Contact authorized
service dealer.

Engine hard to start.

- Water in fuel.
- Weak spark at spark plug.

- Drain entire system and
refill with fresh fuel.
- Contact authorized
service dealer.

Engine lacks power.

- Dirty air filter.
- Engine stored without
treating or draining
fuel, or refueled with
bad fuel.

- Check air filter element.
- Clean or replace as
needed.
- Drain fuel and carburetor.
- Refuel with fresh fuel.

AC receptacle does not work.

Item plugged in is defective. Overload
indicator on (light solid)

- Try a different item.
- Press reset button.

DC receptacle does not work.

- Circuit protector engaged.
- Item plugged in is defective.

- Remove any load from
the generator.
- Replace the fuse,
then depress the DC
circuit breaker.
- Try a different item.

Generator makes a “spark
knock” or “pinging” noise.

- If knocking or pinging
occurs under normal load
at a steady engine
speed, the problem may
be with the fuel
being used.
- An occasional light
“knocking” or “pinging”
under heavy load is not a
cause for concern.

- Switch to a different
brand of fuel with
a octane rating of 86 or
higher.
- Contact authorized
service dealer.

Only use OUTSIDE and
far away from windows,
doors, and vents.

Add engine oil per the Operator’s Manual instructions.

Stopping The Unit
1.

Disconnect all appliances connected to the generator.
Position the Engine Fuel Switch to OFF.

Oil fill recommendations using included oil fill bottle:
P1000i

P2000i

1 oil fill bottles up to #2 mark

2 oil fill bottles up to #2 mark

ON
OFF

Always verify oil level is at upper limit mark on dipstick before operating.

2.

3.

5.

Fill the fuel tank per the Operator’s Manual instructions.
Position the fuel tank cap vent lever to ON, if equipped.

Push the SMART THROTTLE
switch to OFF.

Position the Engine Fuel
Switch to ON.

ON
OFF

4.

6.

Move CHOKE lever right to
START position.

Lightly pull the engine recoil until
resitance is felt. Firmly Pull the
engine recoil until the engine starts.

2.

Allow the engine to cool.
Position the fuel tank cap vent lever to OFF, if equipped.

Using The Generator
Connect devices to be powered by following the steps below.
- Make sure the total rated power from the items you plan to use at the
same time are less than the generator continuous (running) watts. Make
sure the total surge (starting) power from the items you plan to use at the
same time are less than the generator maximum watts. See Operator’s
Manual to calculate total amount of power needed.
- Start the generator with nothing connected.
- Plug in and turn on the first load (perferably the largest load).
- Allow the generator output to stabilize (engine runs smoothly and
attached device operates properly).
- Repeat previous steps for additional loads.
IMPORTANT: Never add more load than the generator’s capacity. Please consider surge
load when determining total power need.

SOLUTION

Engine will not start.

First Time Starting
1.

POSSIBLE CAUSE

If problems persist after trying the above solutions, contact your authorized service dealer.
The following symptoms may indicate problems that will affect the emissions level on the unit.
- Hard starting or stalling
- Rough idle
- Misfiring or backfiring under load
- Afterburning (backfiring)
- Black exhaust smoke or high fuel consumption
If you encounter any of these symptoms, take the unit to your authorized service dealer for service.

Storing The Unit

When preparing to store the generator, allow the unit to cool completely. If the unit is going
to be stored for more than 4 weeks, drain fuel by releasing the carburator drain screw.
Follow complete storage instructions in Operator’s Manual.

9926057 R2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Create Date                     : 2014:11:21 13:01:52-06:00
Creator                         : Adobe InDesign CS6 (Windows)
Modify Date                     : 2014:11:24 15:14:49-06:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:11:24 15:14:49-06:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:cc0d201f-9c8b-4471-b7ae-ff306725ecd5
Original Document ID            : xmp.did:5BF41C92AA71E411B590D82C1C9B218D
Document ID                     : xmp.id:81A4E54AAF71E411B590D82C1C9B218D
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:7EA4E54AAF71E411B590D82C1C9B218D
Derived From Document ID        : xmp.did:7EA4E54AAF71E411B590D82C1C9B218D
Derived From Original Document ID: xmp.did:5BF41C92AA71E411B590D82C1C9B218D
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:11:21 13:01:52-06:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 1
EXIF Metadata provided by EXIF.tools

Navigation menu