BriarTek ORCA Overboard Recovery Communications User Manual ORCA User s Guide revision March 27

BriarTek Inc. Overboard Recovery Communications ORCA User s Guide revision March 27

Users Manual

Download: BriarTek ORCA Overboard Recovery Communications User Manual ORCA User s Guide revision March 27
Mirror Download [FCC.gov]BriarTek ORCA Overboard Recovery Communications User Manual ORCA User s Guide revision March 27
Document ID271857
Application ID5NsBCIY/auRai56NL7Ntaw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.3kB (303717 bits)
Date Submitted2002-09-20 00:00:00
Date Available2002-11-18 00:00:00
Creation Date2002-07-30 14:41:19
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2002-07-30 14:41:19
Document TitleORCA-User's Guide revision March 27
Document CreatorADOBEPS4.DRV Version 4.50
Document Author: accounting

ORCA™
VERBOARD
ECOVERY
OMMUNICATIONS
User’s Guide
Briar
TM
Tek
Incorporated
Applied Innovations
PPARATUS
If you have any questions or need
technical support contact:
Technical Support
BriarTek Incorporated
112 East Del Ray Ave
Alexandria, Virginia 22301
Telephone: (703)548-7892 Extension 205
Email: support@briartek.com
ORCA™
User’s Guide
March 2002
BriarTek Inc.
112 E. Del Ray
Suite A
Alexandria, VA 22301
ORCATM (Overboard Recovery Communications Apparatus) is a personal water-activated man overboard (MOB) alarm system developed by BriarTek Inc.
The alarm system includes a signal device transmitter (TX100-base model), a
receiving station (RX100-base model), and an optional direction finder (RDF).
ORCATM aids in the detection, location and recovery of individuals who become separated from the safety of their vessel, and thus exposed to the harsh
elements of the sea. When the alarm is activated, ORCATM transmits an initial
FM message from the victim to the victim's shipboard receiver. The onboard
alarm sounds upon receipt of a valid message. If the wearer of the transmitter
does not disable the alarm within one (1) minute, the ORCATM will begin
transmitting an AM alerting signal that can be received by standard SAR
equipment including most types of RDFs. The ID data will be rebroadcast on
average every minute.
ORCA thus allows for a locally managed MOB situation ensuring that a victim
is recovered quickly so as to minimize effects of exposure. Search and rescue
(SAR) assets outfitted with direction finding equipment are capable of homing
in on the 121.5 MHz emergency frequency to aid in a recovery effort.
WARRANTY INFORMATION
WARRANTY INFORMATION
Please detach and complete the following warranty information and mail
to BriarTek Inc. at the address listed below. This updates our owner records and places you on our private mailing list for updated product and
service information.
User Name __________________________________________
User Address ________________________________________
City/State/ZIP _______________________________________
User Affiliation (U.S. Navy, Coast
Guard, comm. boating, etc…) __________________________
ORCATM Special Features:
•
Capable of communicating with rescue authorities and other ships
in the immediate area.
•
Uses patented technology to communicate with the ship in an emergency.
•
Provides unique identification.
•
The RX100 can be used to determine how many sailors are in the
water and in need of rescue.
•
Enables the user to signal “All Clear” to all receivers in the event of
an inadvertent activation.
•
The TX100 has very low current consumption for longer battery
life.
•
The TX100 uses standard 9 volt alkaline batteries.
Model #: _________________ Serial #: _________________
BriarTek Incorporated
112 East Del Ray Ave
Alexandria, Virginia 22301
14
WARRANTY
BriarTek Inc. guarantees each product it distributes to be free from defective materials and workmanship and agrees to remedy any such defect, or to furnish a new or equal part in exchange (at its option) for a
period of one year from the date of purchase. For an exchange of the
product, carefully pack the equipment and return to BriarTek Inc. at the
following address:
BriarTek Inc.
112 E. Del Ray Ave
Suite A
Alexandria, VA 22301
This warranty is void if equipment has been subject to misuse, improper
installation by a non-BriarTek employee or designee, or has been repaired or altered by a non-BriarTek employee or designee.
FACTORY REPAIR
For repairs not covered by the warranty, or for repairs after the warranty
expires, the factory offers repair service for a nominal charge. For service, carefully pack the equipment and return to BriarTek Inc. at the address listed above. Please include a description of the problem as well
as your name, address and telephone number along with the package.
13
TRANSMITTER OPERATION
Parts Overview - See Figure 1.
A. Manual Activation/Test Button (ON)Depress for test purposes to
confirm the operability of
ORCA™ TX 100.
B. Reset Button (OFF) - Depress to reset
ORCA™ from ‘Transmit Mode’
to ‘Armed Mode’.
C. Water Sensors - Detects the
presence of water in a man
overboard situation. Keep
clear of debris!
D. LED/Antenna - Flashing LED
confirms the transmission of
emergency signal during a man
overboard situation or during
operational testing.
Figure 1. ORCA TM TX100
Activation - Insert an alkaline 9-volt battery into the rear panel of ORCA
(all ORCATM TX100s are shipped from the factory with new batteries installed). This will automatically arm ORCATM until activated through a man
overboard situation or by depressing the ON button for manual activation or
operational tests. Once activated, the LED will begin blinking to indicate it is
transmitting an emergency signal. The emergency signal contains identification data tones to be decoded by the matching receiver, in addition to an extended RDF transmission to aid in the location and recovery of the sailor overboard.
Once the device is activated, the LED will flash on and off for approximately
10 seconds. Once the unit begins to transmit an alert it will turn on and stay on
for at least a minute as the unit transmits the alert and ID code to the receiver
using FM mode. Once the ID codes have been sent the unit will transmit an
audible tone in AM mode to allow RDF equipment an opportunity to locate the
device. When the unit is transmitting in AM mode the LED will flash, and
when the unit is transmitting in FM mode the LED will remain illuminated.
Deactivation - The OFF button should generally be used if the transmitter was
unintentionally activated. DO NOT DEPRESS THE OFF BUTTON IF YOU
HAVE FALLEN IN THE WATER. To deactivate ORCATM, simply depress
the OFF button for approximately one second. Continue depressing the OFF
button until the LED powers off.
Notes
NOTE - Deactivation resets ORCATM to its armed mode until activated to
transmit again or until the user removes the battery
Low Battery Indicator - The ORCATM is equipped with an internal low battery
indicator circuit. To determine if the battery needs to be replaced follow these
steps.
1. Activate the unit by depressing the ON
button
2. As soon as the LED begins to flash
depress and hold the OFF button
3. If the LED turns on and remains on for
10 seconds prior to unit shut off, the
battery is still useable. If however the
LED flashes on and off prior to
shutting down, the battery should be
replaced.
Battery Replacement - Using a small Phillips
head screwdriver, unscrew the two battery
door screws on the rear panel of ORCATM. Be
careful not to lose battery door gasket and
screws when replacing battery. Open battery
door and remove used battery by holding
battery connector and disconnecting battery.
See figure 2. Caution: Applying excessive force
on battery lead when disconnecting battery
may break battery lead and cause unit to fail.
Figure 2. Battery Removal
12
Notes
Attach new 9-volt alkaline battery and place in battery housing. Ensure battery
door gasket is correctly seated (see figures 3 and 4). Battery connector lead
should not interfere with seal between battery door gasket and battery compartment (see figures 5 and 6). Close and screw down battery door.
Figure 3. INCORRECT gasket seating
Figure 4. CORRECT gasket seating
Figure 5. INCORRECT battery
connector lead
11
Figure 6. CORRECT battery
connector lead
How To Wear The Beacon
The beacon should be worn in a manner such that the beacon will be easily accessible should the person fall overboard. If the user intends the beacon to activate automatically in the water, the beacon should be worn so that the water
sensors would be underwater and the antenna would be above water when the
person is floating in the water.
Receiver
Receiver
Size: 7.9 in x 5.9 in x 2.75 in
Weight: 15.2 oz
Power source: One (1) 9V alkaline battery or wall adaptor
Current draw (typical): 55 mA
RF sensitivity: .25 - .60 uVpd
RF Input Impedance: 50 ohms
Adjacent Channel Rejection: 70 dB
Figure 7. TX100 placement - no
PFD
Figure 8. TX100 placement PFD
10
SPECIFICATIONS
RECEIVER OPERATION
Transmitter
Transmitter
Size: 3 in x 1.5 in. x 1.7 in
Weight: 5.6 oz
Range: 2 miles (surface to surface) Ranges of 20 miles have been recorded
when alerting an elevated antenna.
Power source: One (1) 9V alkaline battery
Parts Overview - See Figures 9 and 10
A.
LCD - Displays MOB
B.
Keypad - Data input
C.
Buzzer - Audible alarm
D.
Serial Connector
E.
Antenna jack
F.
Power jack
G.
Audio jack
H.
Power switch - Activates receiver to receive MOB
transmissions.
Battery Life: One year or one activation. Once activated a minimum of 24
hours transmission time.
Activation:
- Manual
- Water
Current draw:
-Armed
-Sleep
-Transmitting
10uA
1 mA
18mA
Modulation Frequency: 121.5MHz FM/AM
Frequency accuracy: +/- 2.0 kHz
Figure 9. ORCATM RX100 - face panel
Spurious and harmonic output:
-typical –60dBm
-max –45dBm
FM deviation: 1.5 – 3.5 kHz
Modulation bandwidth: 0 – 1500 Hz
Operating temperature: -10 deg C to +55 deg C
Storage temperature: -40 deg C to +80 deg C
Figure 10. ORCATM RX100 - end panel
Automatic Systems Diagnostics
Receiving MOB Transmissions
Connect the antenna to the UHF coaxial antenna connector “E”.
The ON/OFF switch ‘H’ is a rocker switch that, when in the ON position,
powers up the RX100 using 12VDC applied at the 1.3 mm 12VDC jack
“F”. The RX100B also comes with a backup 9VDC battery connector.
The LCD “A” will display “ORCA v___” after the system has initialized.
It will then begin scanning and will remain in this mode until it receives a
MOB transmission.
When a MOB transmission is received, the LCD will indicate which transmitter has been activated and an audible alarm will sound. The alarm is a
piezo-electric buzzer providing a 100 dB alert.
When an alarm is received, the user should depress the asterisk on the keypad to silence the alarm. Note: This only silences the alarm, it does not
clear the MOB from the database.
If more than one transmitter has been activated, the LCD will display each
transmitter in sequence as the respective signals are received.
When the receiver is turned on a pattern of asterisks should flash across the top
of the LCD indicating that the system is functioning properly. If this pattern
stops or fails to appear the receiver will not receive alarms. The receiver
should be reset for 5 seconds and then turned on. If the test pattern appears indicating normal operations then no further servicing is required. If the test pattern fails to appear and move from left to right then the unit is broken and
should be returned to the manufacturer for servicing.
To register a transmitter as belonging to ownship
Resetting the Receiver
Press the A button on the receiver keypad. The LCD should change to display
“Activate the ORCA to be registered.” Follow the on screen instructions, activate the transmitter and as soon as the transmitter is identified by the receiver,
the receiver will display “If ID number is correct press A.” NOTE: the ID
number is the same as the transmitter serial number, this number can be found
in two places. One label with the serial number is on the back of the transmitter unit, the other label is located inside the battery compartment. If the ID
number displayed on the receiver is not correct, press the B button on the keypad and restart the process. Once the unit is registered the transmitter should
be turned off. To exit setup mode press the D button on the keypad.
To delete transmitter(s) from the ownship list
To reset the receiver, push switch to the OFF position, wait 5 seconds and
then push it back to the ON position. Once the receiver has been reset, it
will continue to receive MOB transmissions from ORCA if the individual transmitters have not been reset to the armed mode. Note: A receiver
reset will not clear the MOB data currently in the database.
When an individual ORCA transmitter is reset, the receiver’s LCD will
display “ALARM RESET”. This only removes that transmitter’s ID from
the receiver’s system. The identification numbers of all other active
ORCAs will remain displayed on the receiver’s LCD.
To delete one or more selected transmitters from the ownship list, press the B
button on the receiver keypad. The LCD should change to display “Activate
the ORCA to be Unregistered.” Follow the on screen instructions, activate the
transmitter and as soon as the transmitter is identified by the receiver, the receiver will display “If ID number is correct press A” NOTE: the ID number is
the same as the transmitter serial number, this number can be found in two
places. One label with the serial number is on the back of the transmitter unit,
the other label is located inside the battery compartment. If the ID number
displayed on the receiver is not correct, press the B button on the keypad and
restart the process. Once the unit is unregistered the transmitter should be
turned off. To exit setup mode press the D button on the keypad.
To clear MOB from the ownship list
To clear the receiver of all MOB ownship contacts, press the C “Clear MOB
List.” NOTE: The MOB list cannot be deleted by cycling power to the receiver. It must be cleared by this procedure. It is meant to force attention to
the registerred man over board alarm. If power is recycled, an uncleared
MOB’s will reactivate the alarm.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2002:07:30 14:41:19-04:00
Modify Date                     : 2002:07:30 14:41:19-04:00
Page Count                      : 10
Creation Date                   : 2002:07:30 18:41:19Z
Mod Date                        : 2002:07:30 18:41:19Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : accounting
Metadata Date                   : 2002:07:30 18:41:19Z
Creator                         : accounting
Title                           : ORCA-User's Guide revision March 27
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QJYORCA

Navigation menu