Bron Elektronik RFS2 RFS Transceiver Module User Manual Annex No 5 01

Bron Elektronik AG RFS Transceiver Module Annex No 5 01

User Manual

Annex No.5              User Manual Functional Description
Radio System for Studio Flash Equipment          914.0MHz: RFS Transceiver Module L7272.03/ L7272.13/ L7272.23 916.5MHz: RFS Transceiver Module L7272.01/ L7272.11/ L7272.21     Bron Elektronik AG, 4123 Allschwil, Switzerland       The application concerns the data transmission from an operator console (MAC/PC) to the flash units of a Photo Studio, in both directions, as well as the transmission of a flash trigger signal from the camera to all of the flash units.
 ---------------  Studio flash unit  ----------------     The radio equipment in the studio flash unit consists of a RFS transceiver module (three versions) and a unit specific RFS interface      916.5MHz  Flash unit „Grafit“:        RFS Transceiver Module L7272.01 and RFS Interface L 7273.00 Flash unit „Topas“:        RFS Transceiver Module L7272.11 and RFS Interface L 7275.00 Flash unit „Minicom/Logos“: RFS Transceiver Module L7272.21 and RFS Interface L 7274.00  914.0MHz  Flash unit „Grafit“:        RFS Transceiver Module L7272.03 and RFS Interface L 7273.00 Flash unit „Topas“:        RFS Transceiver Module L7272.13 and RFS Interface L 7275.00 Flash unit „Minicom/Logos“: RFS Transceiver Module L7272.23 and RFS Interface L 7274.00         RFS Transceiver Module specifications ( typical ):  •  Output power:     12dBm •  Frequency:      914.0 – 916.5MHz •  Modulation:     ASK •  RF input impedance    50 ohms •  Data rate / Data format:        38.4 kBaud Æ 76.8kBit in Manchester •  Transmission time flash triggering:    0.625ms – 0.833ms •  Transmission time data-block:    1.9ms – 10.4ms •  Size:      35mm x 52mm x 12mm •  Operating voltage:    3V •  Operating current:    2mA receive mode 10µA power down mode
Interface connector:  Pin Description 1   3V_PA: power amplifier 2   RXDATA:  76.8kBit  Manchester (baud rate= 38.4kBaud) 3  Ground 4   TXMOD:  76.8kBit  Manchester (baud rate= 38.4kBaud)  5   PA_IO: power amplifier control, 0=receive, 1=transmit 6   CNTRL1: 7   CNTRL0: 8   3V: power input  CNTRL1: CNTRL0:  control 0  0   power down mode 0  1   OOK transmit mode 1  0   ASK transmit mode 1  1   receive mode    Transmission format  Data format:   MSB first  Flash-block: •  Preamble   11100110  01100110    optimisation of DC-balance •  Start symbol „Flash“:   01110001  11010110 Manchester modified •  ID (Studio no.) 01010101  01010110    Æ ID=1   ( Manchester )   Data-block: •  Preamble:   11100110  01100110    optimisation of DC-balance •  Start symbol „Data“:   01110001  11011001 Manchester modified  •  Block number:  ...    each new block receives a new  block number, but not a repetition. •  Byte count:  ... •  Start info:  01011010  01011001    •  Studio ID: 01010101  01010110    Æ ID=1   ( Manchester ) •  Unit ID:  ... •  n data  ... ... ... ...  max. 50 Byte •  Check sum:  ... •  End Symbol „Data“:   01110110  00100110 Manchester modified   A dual directional data transmission only takes place when the setting on the flash units or the operator console (MAC/PC) is adjusted. This reduces the probability of a collision with a flash-block. A correctly transmitted data-block is confirmed with an ACK. An unconfirmed data-block is repeated.  A flash-block is not repeated.
Flash unit Grafit: RFS Transceiver Module L7272.01/ L7272.03 and RFS Interface L7273.00  The RFS transceiver module and the RFS interface are connected by a flat cable. A straight SMC connector is soldered, on the front end, onto the transceiver module and a ¼-wave antenna is mounted. The RFS transceiver module has a soldered-on shield.
  Flash unit Grafit
Flash unit Topas: RFS Transceiver Module L7272.11/ L7272.13 and RFS Interface L7275.00   The RFS transceiver module and the RFS interface are connected by a flat cable. An angle SMC connector is soldered onto the RFS transceiver module and a ¼-wave antenna is mounted.
  Flash unit Topas
Flash unit Minicom/Logos: RFS Transceiver Module L7272.21/ L7272.21 and RFS Interface L7274.00   The RFS transceiver module is attached directly onto the RFS interface. The rod-type antenna Z7276.00 is soldered into the RFS transceiver module. In the RFS interface, there are no components assembled in the section around the RFS transceiver module. In this section, the Cu-surface, together with a metal frame, serve as a shield.
  Flash unit Minicom
  Flash unit Logos
SMC-Antenna  No. 40462.00        PRODUCT CODE :- SMCUHFF915MHz .    Manufacturer : R.W. Badland Ltd. England Tuned frequency :-915 Mhz .  Gain [ unity ] ¼  wave  0 db Radiator::- flexible plastic coated Base :-   moulded in situ Length : - 80 mm Diameter :-   Base  :-   9.5mm                      Centre :- 4.1 mm                       Tip :-     7 mm VWSR :- better than 1.5 : 1 Band width @ 2 : 1 VWSR 5%
Operating Instructions b r o n c o l o r   Minicom 40 / 80  Before use  We are very pleased you have chosen a broncolor Minicom compact unit which is a high-quality product in every respect. If used properly, it will render you many years of good service. Please read the information contained in these operating instructions carefully. They contain important details on the use, safety and maintenance of the appliance. Keep these operating instructions in a safe place and pass them on to further users if necessary. Observe the safety instructions.    Contents page   Important safety instructions  2 Attention:  Read before starting up the compact unit  3 Controls and displays  4  1.  Application Minicom         6 2.  Start up  6 3.  Energy control   7 4.  Modelling light  7 5.  Release  8 6.  Ready signals visual/audible  9 7.  Additional functions with settings  10 8.  Flash tube   12 9.  Protecting glass  12 10.  Fuse  12 11.  Basic settings ex works  12 12.  Protective facilities / Fault indication  14 13.  Car battery converter   15 14.  Mounting 15 15.  Umbrella holder  16 16.  Accessories   16 17.  Maintenance / repairs  16 18.  Technical data  17 19.  broncolor Minicom RFS  18 20.  Order numbers for diverse spare parts / accessories  19  1
Important safety instructions  This unit is designed for professional photography and is to be handled by skilled staff only.  When using your studio flash equipment, basic safety precautions should always be followed, including the following:   1.   Read and understand all instructions before using.   2.  Close supervision is necessary when any appliance is used near children. Do not leave appliance unattended while in use.   3.  Care must be taken as burns can occur from touching hot parts.   4.  Do not operate appliance with a damaged cable or if the appliance has been dropped or damaged – until it has been examined by a qualified service person.   5.  Position the cable so that it will not be tripped over, pulled, or contact hot surfaces.   6.  If an extension cable is necessary, a cable with a current rating at least equal to that of the appliance should be used. Cables rated for less amperage than the appliance may overheat. When using a cable reel, it must be completely unrolled before use to prevent overheating of the cable.   7.  For safety reasons, never operate the appliance without the protecting glass in place.   8.  Always unplug appliance from electrical socket before cleaning and servicing and when in use. Never jerk cable to pull plug from socket. Grasp plug and pull to disconnect.   9.  Let appliance cool completely before putting away.   10.  When putting away and winding up cables, take care they do not get in contact with hot parts of the appliance.   11.  To reduce the risk of electric shock, do not immerse this appliance in water or other liquids.   12.   To reduce the risk of electric shock, do not open this appliance, but take it to a qualified service person when service or repair work is required. Incorrect reassembly can cause electric shock when the appliance is used subsequently.   13.  To avoid a risk of fire, electric shock or any injuries to persons, use only accessories which are recommended by the manufacturer.   14.  Connect this appliance to an earthed socket.  2
Attention:  Read before starting up the compact unit    -  Prior to replace fuses, modelling lamp or flash tubes, discharges the unit anddisconnect it immediately from power supply. Prior to replacing the modelling lampor flash tube, let the unit cool down for a period of 10 minutes.  -  The unit is designed for use in dry conditions. Protect it form water and fromexcessive exposure do dust.    -  The unit is not suitable for use in an environment where there is a risk ofexplosure.  -  The accessories mounted onto to the compact unit may heat up to high temperatures under specific conditions. Handle with care.  -  With due allowance for heat radiation, units with more than 100 W modelling lightmay be directed against inflammable surfaces only at a minimum distance of 1meter.   -  For safety reasons, never operate the unit without protecting glass in place.    -  Flash light contains, similar to sunlight, a specific portion of UV light. Theundesirable side effects on skin and eyes are considerably reduced by using flashtubes and glass covers with an UV coating. Without these or other protectivefilters, use with extreme care when shooting.   -  Even when disconnected from the power supply, dangerous voltages may remaininside the unit. For this reason, units should be opened by authorized broncolor service shops.   -   Do not block the cooling louvers on the unit    -  Only fuses of the type indicated on the safety label may be used. This is especiallyimportant for the halogen lamp which can explode when used with the wrong fuse.    Only use sand-filled fuses. They can be identified by their opaque fuse container.   3
Controls and displays  1. Photocell on/off  2.  IR-receiver and/or RFS-Interface on/off  3.  Umbrella holder   4.  Mains switch on/off  5.  Modelling light on/off   6.1  Sync socket (when required, usable as connection socket for computer link)   6.2  Sync socket   7.  Test release, ready display green   8.  Connection socket for mains cable  9. Fuse  10.  Auxiliary functions (aux)  11.  Operating mode modelling light  12. Flash sequence  13.  Charging dimmer   14. Buzzer   15.  Slow charge   16.  Appliance address (for Minicom 40 RFS / Minicom 80 RFS)  17.  Digital flash energy display   18.  Energy control up/down  19.  IR-receiver and photocell    4
Front panel for Minicom 40 / 80    181917111213141516109543216.1786.2   5
1.   Application Minicom    This mains supplied studio flash unit is designed for professional photography only. In countries with earthed mains systems, use a three-wire extension cable when required.   2.   Start up  2.1 Mains voltage  The compact units Minicom 40 and Minicom 80 are available in two different versions:  a) As a bi-voltage-unit, of which the technical data are optimised for a mains voltage of 200 - 240 V. If this version is operated with a mains voltage of 100 – 120 V, the following restrictions result: Mains voltage 120 V:  doubling of the charging time  Mains voltage 100 V:  doubling  of  the  charging time as well as reduction of the maximum flash energy of 250 J (Minicom 40) respectively 500 J (Minicom 80), extension of the flash duration by 20 %  b) As a bi-voltage-unit, of which the technical data are optimised for a mains voltage of 120 V. If this version is operated with a mains voltage of 200 – 240 V or 100 V, the following restrictions result: Mains voltage 230 V:  doubling of the charging time Mains voltage 100 V:  Extension of the charging time by 20% as well as a reduction of the maximum flash energy of 250 J (Minicom 40) respectively 500 J (Minicom 80), extension of the flash duration by 20 % Attention:  The operating voltage of the modelling lamp must correspond to the mains voltage.  2.2 Earthed mains  Connect unit to current supply always using an earthed mains plug.  2.3 Start up    In the proximity of the halogen lamp, the unit, depending on the accessories used, can acquire high temperatures. For this reason, we recommend to touch the unit only on the rear handle or on the stand adapter. Due to the intense heat radiation when a modelling light is in operation, keep the unit at a minimum distance of 1 meter from flammable surfaces.  1.) Remove the transparent plastic cap by turning and releasing the unlocking slide at the same time. Insert modelling lamp and flash tube as per instructions in chapter 8. Put on the protecting glass as well as the desired light shaper and turn in any direction.  2.) Please check that the mains supply corresponds to the information on the label of the unit. Connect unit to earthed mains.   6
3.) Switch on the unit with the mains switch (4). During charging, the digital flash energy display (17) flashes, afterwards the value is indicated continuously. Additionally the green control lamp of the ready display (7) is illuminated. 4.)  Set the desired flash energy by means of the energy control keys “up / down“ (18). 5.) Switch IR-receiver, photocell or RFS-interface on or off depending on the exposure situation. 6.)  If required, plug in synchronous cable in one of the sync sockets (6.1) or (6.2).    3.   Energy control  Use the „up/down“ keys (18) to control the flash energy (flash intensity) within a range of 4 f-stops. A value of 10 indicates maximum intensity, 6 the minimum. Whole numbers correspond to whole f-stops, decimal places to tenth f-stop steps. There is the option, to extend the control range up to 5 f-stops (see chapter 11), where in the underneath range a slightly higher exposure-tolerance has to be expected. Brief pressure on the energy control keys "up/down" (18) changes the setting by a 1/10 interval, prolonged pressure  by 1/1 f-stop interval. The energy display (17) then flashes until charging or discharging have stabilized the new level of energy.   4.   Modelling light   4.1 General   The Minicom units are equipped with a halogen modelling lamp. The modelling light is switched on by the key “mod“ (5). When switched on, the green diode lights up. To protect the lamp filament from damage, it is advisable to switch off the modelling lamp when handling the compact unit. In chapter 7 you can find the instructions how to set the different operating modes (modelling light proportionality). Attention:  The operating voltage of the modelling lamp must correspond to the mains voltage.  4.2 Proportionality    The brightness of the modelling light can be set proportionally to the flash intensity. To assure proportionality also when units with different power output ratings are operated together, the units have various proportionality levels. Proportionality is guaranteed if the identical prop level has been set for all units. The higher the digit, the brighter the modelling light.    The following operating modes are possible:  “P“  This level can be set if either only Minicom 40 or only Minicom 80 are in use (most intense proportional modelling light). That means, the modelling light is proportional to the energy level 300J respectively 600J.  7
 “P1“  Proportional modelling light with broncolor power packs rated 6400 J.  “P2“  Proportional modelling light with broncolor power packs rated 3200 J.  “P3“  Proportional modelling light with broncolor power packs rated 1600 J.  “P4“  This proportionality level is optimised for an output level of  800 J. Recommended modelling light when using  Minicom 80 in combination with Minicom 40. “P5“  If an unit is operated at a lower output level, the modelling light will be relatively weak and yellowish. To counteract this problem, the Minicom compact units are equipped with the additional modelling light proportionality level “P5“. It is optimised for the output level 400 J and less. Thus the brightness of the modelling light can be increased.  “HI“  The unit operates at full modelling light, independent of flash output. “LO“  The unit operates at lower lighting level, independent of flash output, to reduce power consumption and extend the service life of the halogen lamps.    Pressing the “mod“ key (5) for 1 second when the modelling light is on, will give direct access to the “HI“ mode. To return to the previous mode briefly press the “mod“ key.   4.3  Replacing the halogen lamps    Before replacing the halogen lamp, it is essential to discharge the unit by flashes, immediately afterwards, disconnect it from the power supply.    The halogen lamps are plug-in types. First the protecting glass has to be pulled off carefully in an axial direction (avoid tilting). The protecting glasses for the compact unit Minicom have a marking line and the glass rim has 2 grooves. When removing the protecting glass from the unit the marking line must be situated at the top. Taking into consideration the service life, the halogen lamp should not be touched with bare hands. To exchange the lamp, it must be pulled out of the plug socket in an axial direction.  When inserting, ensure that the lamp is fully pushed back in. When engaging the protecting glass into the locking mechanism of the Minicom compact unit, the marking line must be situated at the top. After having engaged the protecting glass, it must be slightly turned, to prevent accidental loosening.   5.   Release    The flash release is enabled when 75% of the selected energy is available. Please note however , that the ready indicator is activated only at 100% charge (Kap. 6). The release is possible by means of a sync cable, infrared, photocell, or “test” key.  When releasing via the photocell or the IR-receiver, ensure that the receiving cell of the unit is not obstructed by obstacles.   8
The appliance has a synchronous circuit with a low onload voltage to protect your camera contact. The synchronous circuit may not be connected in parallel with products of other manufacturers which operate with high synchronous voltage.  5.1 Photocell   The photocell can be switched on or off by using the “cell“ key (1). If it is activated the green LED lights up. After a flash sequence, an active photocell will be blocked and the green LED blinks. By pressing the "cell" key, the photocell is reactivated.  5.2  Infrared receiver / RFS-interface (ir/rf)  The IR receiver and, if available, the RFS interface can be switched on and off with the key „ir/rf“ (2). Optionally it can be established, if with this key, every time, both functions (IR and RFS) or just one of the two can be switched on or off (see chapter 11). Is one or both functions active, the green display lights up.  5.3  Infrared flash release channel  The Minicom compact units can be released with broncolor infrared transmitters. When the unit is triggered via infrared, the flash release is effected with a time delay of 1/1000 s.   The IR receiver integrated in the unit is used for a wireless release by with following units: -  IRQ transmitter -  IRX 2 transmitter -  FCM 2 lightmeter and contrast photometer -  FCC colour temperature measuring unit  5.4 Sync sockets  The synchronous cables, art. no. 34.111.00 respectively 34.112.00, may be plugged into the sync sockets (1) or (2) to release flashes via cable  5.5 “Test“ key    This „test“ key (7) allows manual release of the compact unit Minicom. The respective LED lights up when the flash voltage corresponds exactly to the selected value. During charging and discharging the LED goes out and the flash energy display (17) blinks.     6.   Ready display visual /audible  6.1  The visual ready display  is the green LED at the „test“ key (7). It lights up only when  unit is at 100% charge. After releasing the flash this LED goes out until the unit is fully charged again.   6.2  The audible ready signal „buzzer“ sounds when the unit is at 100 % charged. It may be switched on or off (chapter 7).   9
6.3  Audible fault signal  When the flash discharge fails, a warning signal of approx. 3 s duration will sound and the flash energy (17) of the compact unit will flash.   7.   Setting additional functions  The “aux“ key (10) is used to set the additional functions. With repeated actuation of the key the following modes can be selected:   •  Setting proportionality level of the modelling light  LED “prop“ blinks (11) •  Define sequence (serial flashes)  LED “seq“ blinks (12) •  Charging dimmer switch on / off  LED “dim“ blinks (13) •  Buzzer switch on / off  LED “buz“ blinks (14) •  Slow charge switch on / off  LED “slow“ blinks (15) •  Setting appliance address / studio address  LED „unit“ blinks (16) •  Return to standard display  no LED blinks  After the setting has been performed, the standard display can be re-activated by pressing the “aux“ key (10) or automatically after a waiting period of approx. 30 seconds.  To select the additional functions and appliance settings, choose the respective LED  (e.g. „charging dimmer switch on/off). The digital display (17) will then show the actual selected value which can be changed by the energy control keys  „up/down“ (18).  If a setting is entered which deviates from the standard setting value or a function is activated, the respective LED will remain lit as a reminder after the display returns to standard (exception: function “prop“).  If the unit is switched off and on again , it will be in the “standard display” mode. Previously set additional functions are retained.   7.1  Setting proportionality level of the modelling light (prop)  The proportionality level of the modelling light can be selected by briefly pressing the energy control keys „up/down“ (18).  With repeated actuation of the key the following modes can be set, each shown respectively on the digital display (17): LO, P, P1, P2, P3, P4, P5, HI.  7.2  Sequence (serial flashes) (seq)  This function allows to set a defined number of flash discharges from 1 to 50. By briefly pressing the energy control keys „up/down“ (18) the required number of flashes can be selected.   10
With a long pressure on the energy control keys “up/down”, the setting changes in intervals of ten. Each release signal triggers the selected number of flashes. A current sequence can be aborted by a long pressure on the energy control keys “up/down” or by switching off and on again the unit. The function is switched off, by setting the number of flashes to „0“.  7.3  Charging dimmer / boost function (dim)  The „dim“ function can be switched on or off (on/--) by briefly pressing the energy control keys “up/down” (18). When switching on the “dim” function with the modelling light on (green LED of the “mod” key (5) lights up), the modelling light switches off while charging takes place. This feature allows visual flash control, to fade out the modelling light during flash sequences or to reduce the current load on weak mains.  If the “dim” function is activated when the modelling light is switched off (green LED of the “mod” key (5) is off), the boost function will be activated. In this mode, the modelling light remains on as a visual flash monitor during charging.  7.4  Buzzer switch on/off (buz)  The ready buzzer signals when the unit is at 100 % charge. The buzzer is switched on or off (on/--) by briefly pressing the energy control keys “up/down” (18). The warning signal also functions with the buzzer switched off.  7.5  Slow charge switch on/off (slow)  In case of weak mains power supply lines, charging time may be extended to approx. double the standard value. The slow charge mode is switched on or off (on/--) by briefly pressing the energy control keys “up/down” (18).  7.6  Studio / appliance address (unit)  The compact units Minicom are also available as versions with built-in RFS Interface (Radio  Frequency  System). For remote control respectively flash release via radio, an individual appliance address and a studio desk top (remote control channel) can be assigned to each RFS unit by means of the function “unit” (16).  To carry out the settings, dial the LED „unit“ using the „aux“ key (10). The digital display (17) shows the letter “U”, followed by an appliance number between 1 and 8. By briefly pressing the energy control keys “up/down” (18), the required value can be selected. When pressing again the “aux” key, the digital display shows the letter “C”, followed by a studio number between 1 and 8. By briefly pressing the energy control keys “up/down”, the required value can be selected.   8.   Flash tube  The flash tube is coated to ensure an optimal colour temperature. For your security, only original flash tubes must be used. For safety reasons, never operate a unit without protecting glass in place.  11
 8.1  Replacing the flash tube    The flash tube is a plug-in type. To replace the flash tube, discharge the unit by flashes, disconnect it from power supply and let it cool off for ten minutes (to discharge the flash capacitors)  1.)  The protecting glasses for the compact unit have a marking line and the rim of the glass  has 2 grooves. When taking off the protecting glass of the unit the marking line must be situated at the top. Pull off the protecting glass carefully in an axial direction. (Avoid tilting).  2.)   Press the spring radially inward and pull the flash tube out of the socket in an axial direction (do not touch the flash tube with bare hands)  3.)  Insert the new flash tube and press the spring radially inward. When inserting ensure that the ceramic socket is fully pushed back in. The spring serves as well as contact and prevents accidental loosening of the flash tube.  4.)   Replace the protecting glass. When engaging the protecting glass into the locking mechanism of the Minicom compact unit the marking line must be situated at the top. After having engaged the protecting glass it must be slightly turned to prevent accidental loosening.  5.)   Connect the unit to the power supply, now it is ready for use again.    9.   Protecting glass  For safety reasons, never operate a unit without protecting glass in place.    10.  Fuse  The fuse (9) is located on the rear of the unit. Sand-filled fuses with value 3.15 AF may only be used (sand-filled fuses can be identified by their opaque fuse container). Using wrong fuses is dangerous; it may cause the halogen lamp to burst. Original broncolor replacement lamps are therefore delivered with the correct fuse.   11.  Basic settings ex work  The basic settings ex work can be viewed and in some instances changed with the following procedure:  When the unit is switched on, simultaneously press the “mod” (5) and “aux” (10) keys for approx. 5 seconds (the LED array “prop” / “seq” / “dim” / “buz” / “slow” / “unit” blinks to indicate that you are in the programming mode).   12
Additionally the LED of the “mod” (5) key is lit. The digital display (17) shows the function number 0. The other function numbers can be selected by pressing the energy control keys “up/down” (18).  By briefly pressing the “aux” key, the digital display shows the actual value respectively the actual setting within the selected function number. The LED of the “mod” key does not light up in this mode. Within the function numbers 1, 2, 3 and 9, the settings can be changed with the energy control keys “up/down”.  Concerning the function numbers 0 and 4 – 8, the different pairs of these multiple digit values can be shown by means of the energy control keys “up/down”.  Return to normal operation by pressing (1 s) the “aux” key, by switching the unit off and on again or automatically after a period of 20 seconds.     Function number  Meaning and possible settings  0 Program version: Standard display Program number:  after pressing the energy control „down“ key   1  Control range flash energy: Setting ex work: "off" (--). Display "on" the control range of the flash energy  is extended on to 5 f-stops (10 - 5.0).   2  Sensibility of the photocell: Setting ex work: "on" This function reduces the sensibility of the photocell. If the function is activated the digital display shows the value “off“.   3  Definition function „ir/rf“: Setting ex work: digital display shows the value "3" = IR receiver and RFS Interface (if available) activated. Display value “1“ = only IR receiver activated  Display value “2“ = only RFS Interface activated.  4 Flash counter: Figure group in the display: xxxxXX = standard display Figure group in the display: xxXXxx = after pressing the energy control „up“ key Figure group in the display: XXxxxx = after pressing the energy control „up“ key  5 Series number of the unit: Figure group in the display: xxXX  6 Series number of the unit: Figure group in the display: XXxx  7 Production date of the unit: Figure group in the display: xxXX = month  8 Production date of the unit:  Figure group in the display: XXxx = year  9 Reduction of the modelling light: Setting ex work: “off” (--) The activation of this function is recommended on power mains with great fluctuations. The voltage for the modelling lamp is reduced (light output ./. 1/3 f-stop), which results in a longer service life of the halogen lamp. If this function is activated, the digital display shows the value “on”.   13
12. Protective facilities / Fault indication  12.1 Cooling fan  The cooling of flash tube, modelling lamp and internal electronics is effected by a cooling fan. It also runs when the modelling light is turned off. The cooling works on two levels, the fan runs smoothly when small flash sequences are effected. With longer flash sequences, the cooling fan switches to the higher level.  12.2 Display “th“  If excessively high temperatures build up inside despite the fan cooling, the charge mode will be blocked and a long audible signal will be generated. The modelling light is blocked as well for about 6 minutes. The digital display shows the indication “th” during the cooling period. The cooling process is accelerated by the fan which is still in operation. Attention: Do not switch off the unit during the cooling period! If the unit is switched off too early, only a small number of flashes can be effected until the next blockout, when switching on again the unit, despite a long break, because the processor could not completely pursue the cooling process.  12.3 Display “A1“    The unit is equipped with an automatic afterglow blockout. If the flash tube exhibits (e.g. at the end of its service life) afterglow, this blockout will block further charging to prevent consequential damage. This status is also discernible by the ready display, which is no longer green. The blockout can be cancelled by switching the unit off and on again.  12.4 Display “A2“    This indication is shown, when the unit is overcharging. Switch off the unit and switch it on again after a few minutes. If this fault continues to exist, please contact an after-sales service centre  12.5  Acoustic flash monitoring    At the end of their service life, flash tubes often have triggering interruptions. This fault is indicated by an audible, intermittent signal. The signal disappears when the flash tube flashes properly again or the unit is switched off.  12.6  Monitoring of the modelling light  If the compact units Minicom are connected to 200 V – 240 V mains voltage, after previously having been operated on 100 V - 120 V mains voltage, they will release an audible signal and the modelling light will blink at a safely reduced voltage. This function serves as a reminder that the modelling lamp must be exchanged, and also to protect against damage of the lamp. Switch the unit off and on again to return to standard operation.    14
13. Car battery converter   If no mains power is available the 12 V-car battery converter can be used to charge the unit (only for 230 V units). The modelling light cannot be used in this operating mode (excessive load on the battery) and must be removed.  •  Switch off the modelling light and remove the halogen lamp •  Connect the converter with the + and – connector clamps to the 12 V car battery. •  Connect the unit to the converter and switch on the unit and the converter  •  Switch off the converter during pauses after flash work. Charge battery if needed by allowing the car engine to run.  Two compact units Minicom can be connected to one converter. Approx. 200 flashes of 300 J respectively 100 flashes of 600 J are possible with a fully charged battery.   14. Mounting  The stand adapter is located below the housing. The adapter is designed for standard broncolor® bolts (12 mm) and Manfrotto® pins (16 mm).  Make sure the unit is firmly attached to the stand before operating. The click-stops of the locking handle can be adjusted by pulling it out.  There are three possibilities for suspended mounting:  a) b) c) The bracket of the compact unit is mounted upwards. To this purpose, dismount the bracket by removing the locking lever as well as the two retaining screws at the side of the unit. Turn over the bracket by directing the stand support upwards. Afterwards insert the bracket in the lower guide rail of the housing and re-insert the locking lever as well as the two retaining screws. In this case the enclosed locking pin must be screwed into the lower part of the stand adapter. This is not required for stand mounting. In this kind of suspended mounting, compared with the following option, the front panel of the unit is still readable (instead of hanging upside down) and the cooling efficiency is not reduced. It is also possible to tilt the compact unit to enable mounting of the bracket with upwards directed stand support. Also in this case the enclosed locking pin must be screwed into the lower part of the stand adapter. An alternative bracket for suspended mounting is available under art. no. 35.228.00. The above mentioned instructions are also valid for this application.  Attention: A safety cable must be installed whenever the unit is suspended.       15
15. Umbrella holder  Diffusing and reflex umbrellas are used in conjunction with the umbrella reflector (art. no. 33.496.00).The umbrella bar is inserted into the special holder in the stand adapter.   16. Accessories   By using the Pulso-bajonet the whole range of broncolor reflectors is at your disposal. You will find the complete overall view in the broncolor system catalogue „creative work with light and with system”.   17. Service / repair  Your broncolor compact unit is a precision device which will work for many years without malfunction if you take proper care of it. If nevertheless malfunctions do arise, please do not attempt to open the unit to repair it yourself. Even when the unit is switched off, dangerous voltages may remain within the interior of the device. Always leave service and repairs to the broncolor after-sales service.    16
18.  Technical data    Minicom 40  Minicom 80     Flash energy   300 J (100 V: 250 J)  600 J (100 V: 500 J) F-stop in 2 m distance 100 ISO, reflector  P50 // P70 32 5/10 // 22 5/10 (100 V: 32 2/10 // 22 2/10) 45 5/10 // 32 5/10 (100 V: 45 2/10 // 32 2/10) Flash duration t 0.1 (t 0.5)  1/900 s (1/2500 s) with mains voltage 110 – 240 V 1/420 s (1/1500 s) with mains voltage 110 – 240 V   Flash duration with mains voltage 100 V: ca. 20% longer Charging time  (for 100% of the selected energy) 230 V / 50 Hz: 0,3 – 0,9 s 120 V / 60 Hz: 0,3 – 1,2 s 100 V / 50 Hz: 0,3 – 1,5 s 230 V / 50 Hz: 0,4 – 1,4 s 120 V / 60 Hz: 0,4 – 1,9 s 100 V / 50 Hz: 0,4 – 3,0 s   Can be switched to slow charge mode  Attention: The above mentioned charging times do not apply to units being operated on alternative mains voltages.   The technical data for these units are optimised for a certain mains voltage (200-240 V or 120 V). If the unit is operated with a alternative mains voltage the charging time increases. When operating the unit with mains voltage of 100 V the maximum flash energy reduces to 250J (Minicom 40) respectively to 500J (Minicom 80).  Controls   Illuminated digital display, LED-display as well as dust and scratch-proof illuminated silicone keyboard Control range of flash energy  (Japan: ⅓ f-stop less) Over 4 f-stops in 1/10 f-stop increments (1:16); Can be extended to 5 f-stops (1:32) Modelling light  Halogen max. 300 W  Proportional to the flash energy as well as „full” and “low” settings.  Proportionality adjustable to all broncolor flash systems and the different output levels. Attention:  The operating voltage of the modelling lamp must correspond to the mains voltage. Flash release  Manual release button, photocell ( can be switched off), infrared receiver (can be switched off), sync cable FCM 2, FCC, IRX2, IRQ Ready display  Visual and audible (can be switched off) signals when 100% of selected energy is reached  Flash monitoring   Visual:  Dim and boost function for modelling light Audible: Buzzer Additional function  - Sequences (serial flashes up to 50 flashes) - Sensibility of the photocell may be reduced Number of sync sockets  2 Stabilized flash voltage  +/- 1,5% Cooling Fan Standards  EC standards 73/23, UL 122 Power requirements  200-240 V / 50-60 Hz:  6 A 100-120 V / 50-60 Hz:  10 A  Minicom 40  Minicom 80     Dimensions (L x W x H)  286 x 154 x 194 mm  286 x 154 x 194 mm Weight kg  3,0  3,3     17
19. broncolor Minicom RFS / Minicom plus    The compact units Minicom are also available as unit version with integrated 8 channel RFS Interface (Radio  Frequency  System). Each channel (studio) can control up to 8 units. This interface allows remote control respectively flash release by radio via transmitter RFS as well as by means of a transceiver RFS via PC or Macintosh computer. When controlling via screen, 4 storage spaces for different lighting situations are at your disposal.  19.1  Modification to Minicom RFS  There is the possibility, to modify Minicom compact units later on with a RFS interface. The modification will be made by the customer service centre of our broncolor agency in your country.   19.2 Minicom plus Because of the laws in some countries, the use of the broncolor radio system is not allowed. Therefore the Minicom compact units are also available in the version Minicom Plus (that means with cable remote control). Besides the cable connection between the compact unit and the computer, the application with RFS is almost identical.    Attention: There is no camera transmitter available for Minicom!    19.3 Technical data    Minicom RFS  Minicom plus Remote control  With integrated 8 channel RFS interface (Radio  Frequency  System) for the remote control of the unit by radio via transceiver RFS from PC or Macintosh computer. Each channel (studio) can control up to 8 units. With integrated interface for the remote control of the unit by cable from PC or Macintosh computer. Each channel (studio) can control up to 8 units. Flash release  Transmitter RFS, Transceiver RFS (besides the options in chapter 18)   analogue chapter 18 Operational distance outdoors Up to 30 m  Length of the connection cable from the computer to the unit: 5m  Length of the connection cable between the units  2,5 m Operational distance in closed rooms up to20 m  see above Range  up to 300 m  see above Number of sync sockets  2  1 (the second sync socket is configured as connection for the computer cable)  Norms  UL 122, EC norms73/23, 89/336 and 99/5 ERM  EN 300 220-1,-3 EMC  EN 301 489-1,-3  EN 60950  EN 50371   FCC Part 15 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and  18
 19(2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.   Subject to change in the interest of product enhancement.    20.  Order numbers for diverse spare parts   /accessories   Flash tube 5500 K for Minicom 40 / 80  Art. no. 34.307.55 Halogen modelling lamp 300 W / 120 V  Art. no. 34.225.XX Halogen modelling lamp 300 W / 230 V  Art. no. 34.231.XX Halogen modelling lamp 150 W / 230 V  Art. no. 34.250.XX Halogen modelling lamp 150 W / 120 V  Art. no. 34.251.XX Protecting glass clear 5500 K  Art. no. 34.336.55 Protecting glass clear 5900 K  Art. no. 34.336.59 Protecting glass mat 5500 K  Art. no. 34.337.55 Protecting glass mat 5900 K  Art. no. 34.337.59 Fuse 3.15 AF  Art. no. 37137.00 Protection cap for transport, transparent  Art. no. Z6750.00 Mains cable CH 200-240V  Art. no. 39084.00 Mains cable USA 100-120V  Art. no. 39085.00 Mains cable Europe 200-240V  Art. no. 39086.00 12 V battery converter   Art. no. 36.450.XX Bracket for suspended mounting  Art. no. 35.228.00
Operating Instructions V I S A T E C   LOGOS 800 / 1600  Before use Please read all the information contained in these operating instructions carefully. They contain important details on the use, safety and maintenance of the appliance. Keep these operating instructions in a safe place and pass them on to further users if necessary. Observe the safety instructions.   Contents Page Important safety instructions  2 Attention: Read before starting up the compact unit  3 Controls and displays  4 1. Application LOGOS  6 2.  Start up  6 3.  Energy control  7 4.  Modelling light  7 5.  Release  8 6.  Ready signals visual / audible  8 7.  Additional functions with settings  9 8.  Flash tube  11 9.  Protecting glass  11 10.  Fuse  11 11.  Basic settings ex works  11 12.  Protective facilities / Fault indication  13 13.  Car battery converter  14 14.  Mounting 14 15.  Umbrella holder  14 16.  Accessories 15 17.  Maintenance / repairs  15 18.  Technical data  16 19.  VISATEC LOGOS RFS  17 20.  Order numbers for diverse spare parts / accessories  18   - 1 -
Important safety instructions  When using your studio flash equipment, basic safety precautions should always be followed, including the following:  1.  This mains supplied studio flash is designed for professional photography.   2.  Read and understand all instructions before using.  3.  Close supervision is necessary when any appliance is used near children. Do not leave appliance unattended while in use.  4.  Care must be taken as burns can occur from touching hot parts.  5.  Do not operate appliance with a damaged cable or if the appliance has been dropped or damaged – until it has been examined by a qualified service person.  6.  Position the cable so that it will not be tripped over, pulled, or contact hot surfaces.  7.  If an extension cable is necessary, a cable with a current rating at least equal to that of the appliance should be used. For your own safety, use a three-wire extension cable. Cables rated for less amperage than the appliance may overheat. When using a cable reel, it must be completely unrolled before use to prevent overheating of the cable.  8.  For safety reasons,  never operate the appliance without the protecting glass in place.  9.  Always unplug appliance from electrical socket before cleaning and servicing and when not in use. Never jerk cable to pull plug from socket. Grasp plug and pull to disconnect.   10.  Let appliance cool completely before putting away.  11.  When putting away and winding up cables, take care they do not get in contact with hot parts of the appliance.  12.  To reduce the risk of electric shock, do not immerse this appliance in water or other liquids.  13.  To reduce the risk of electric shock, do not open this appliance, but take it to a qualified service person when service or repair work is required. Incorrect reassembly can cause electric shock when the appliance is used subsequently.  14.  To avoid a risk of fire, electric shock or any injuries to persons, use only accessories which are recommended by the manufacturer.  15.  Connect this appliance to an earthed socket.   - 2 -
Attention:  Read before starting up the compact unit:   -  Prior to replacing fuses, modelling lamp or flash tubes, discharge the unit anddisconnect it immediately from power supply. Prior to replacing the modelling lamp or flash tube, let the unit cool down for a period of 10 minutes.  -  The unit is designed for use in dry conditions. Protect it from water and fromexcessive exposure to dust.  -  The unit is not suitable for use in an environment where there is a risk of explosion. -  The accessories mounted onto to the compact unit may heat up to hightemperatures under specific conditions. Handle with care.  -  With due allowance for heat radiation, units with more than 100 W modelling lightmay be directed against inflammable surfaces only at a minimum distance of 1meter.  -  For safety reasons, never operate the unit without protecting glass in place.   -  Flash light contains, similar to sunlight, a specific portion of UV light. Theundesirable side effects on skin and eyes are considerably reduced by using flashtubes and glass covers with an UV coating. Without these or other protectivefilters, use with extreme care when shooting.  -  Even when disconnected from the power supply, dangerous voltages may remain inside the unit. For this reason, units should be opened by authorized VISATECservice shops.  -   Do not block the cooling louvers on the unit.   -  Only fuses of the type indicated on the safety label may be used. This is especiallyimportant for the halogen lamp which can explode when used with the wrong fuse.   Only use sand-filled fuses. They can be identified by their opaque fuse container.   - 3 -
Controls and displays  1.  Sync socket (when required, usable as connection socket for computer link)  2.   Sync socket  3.   Photocell on / off  4.   Modelling light on / off  5.   Test release, ready display green  6.   Connection socket for mains cable  7.   Fuse  8.   Energy control up / down  9.   Mains switch on / off  10.  Digital flash energy display  11.  Auxiliary functions (aux)  12.  Operating mode modelling light  13. Flash sequence  14. Charging dimmer  15. Buzzer  16. Slow charge  17. Photocell  18.  Appliance address (for LOGOS 800 RFS / LOGOS 1600 RFS)    - 4 -
 Front panel for LOGOS 800 / 1600      12458971012 13 14 15 16 1711auxauxprop seq buz slowdim unittestmodsync / comsynccell1863    - 5 -
1.   Application LOGOS    We are very pleased you have chosen a VISATEC LOGOS compact unit which is a high-quality product in every respect. If used properly, it will render you many years of good service.    This mains supplied studio flash is designed for professional photography. For your own safety, use a three-wire extension cable when required.   2.   Start up  2.1 Mains voltage  The compact units LOGOS 800 and LOGOS 1600 are available in two different versions:  a) As a bi-voltage unit, of which the technical data are optimised for a mains voltage of 200 - 240 V. If this version is operated with a mains voltage of 100 – 120 V, a doubling of the charging time results. b) As an unit, which is exclusively designed for mains voltage of 100 - 120 V.  2.2 Earthed mains  Connect unit to current supply always using an earthed mains plug.  2.3 Start up    In the proximity of the halogen lamp, the unit, depending on the accessories used, can acquire high temperatures. For this reason, we recommend to touch the unit only on the handle at the rear or on the stand adapter. Due to the intense heat radiation when a modelling light is in operation, keep the unit at a minimum distance of 1 meter from flammable surfaces. 1.) Remove the grey plastic protecting cap by turning and releasing the unlocking slide at the same time. Insert modelling lamp and flash tube as per instructions in chapter 8. Put on the protecting glass as well as the desired light shaper and turn in any direction. 2.) Please check that the mains supply corresponds to the information on the label of the unit. Connect unit to earthed mains. 3.) Switch on the unit with the mains switch (9). During charging, the digital flash energy display (10) flashes, afterwards the value is indicated continuously. Additionally the green control lamp of the ready display (5) is illuminated. 4.)  Set the desired flash energy by means of the energy control keys “up / down“ (8). 5.)  Switch photocell (17) on or off, depending on the exposure situation. 6.)  If required, plug in synchronous cable in one of the sync sockets (1) or (2).     - 6 -
3.   Energy control  Use the „up / down“ keys (8) to control the flash energy (flash intensity) within a range of 4 f-stops. A value of 10 indicates maximum intensity, 6 the minimum. Whole numbers correspond to whole f-stop intervals, decimal places to tenth f-stop steps. Brief pressure on the energy control keys “up / down“ (8) changes the setting by a 1/10 interval, prolonged pressure by 1/1 f-stop interval. The energy display (10) then flashes until charging or discharging have stabilized the new level of energy.   4.   Modelling light  4.1 General  The LOGOS compact units are equipped with a very bright 150 W halogen modelling lamp. The modelling light is switched on by the key “mod“ (4). When switched on, the green diode lights up. In chapter 7 you can find the instructions how to set the different operating modes (modelling light proportionality).  4.2 Proportionality    The brightness of the modelling light can be set proportionally to the flash intensity. To assure proportionality also when units with different power output ratings are operated together, the units have various proportionality levels. Proportionality is guaranteed if the identical prop level has been set for all units. The higher the digit, the brighter the modelling light. The proportionality levels of the LOGOS compact units are compatible with those of the broncolor units.    The following operating modes are possible:  “P“  This level can be set if either only LOGOS 800 or only LOGOS 1600 are in use (most intense proportional modelling light). That means, the modelling light is proportional to the energy level 300J respectively 600J. “P1“  weak proportional modelling light, applicable for all types of units “P2“  recommended modelling light when using LOGOS 1600 (also in combination with LOGOS 800) “P3“  recommended modelling light when using only LOGOS 800  “P4/5“  If an unit is operated  at a lower output level, the modelling light will be relatively weak and yellowish. To counteract this problem, the LOGOS compact units are equipped with two additional modelling light proportionality levels: “P4“ for 150 J or less and “P5“ for 75 J or less. Thus the brightness of the modelling light can be increased. “HI“  The unit operates at full modelling light, independent of flash output. “LO“  The unit operates at lower lighting level, independent of flash output, to reduce power consumption and extend the service life of the halogen lamps.    - 7 -
  Pressing the “mod“ key (4) for 1 second when the modelling light is on, will give direct access to the “HI“ mode. To return to the previous mode briefly press the “mod“ key.  The halogen lamp can be plugged in; when exchanging, do not touch the lamp with bare hands. Please note that the flash tube must be pulled out before exchanging the halogen lamp.   5.   Release  The flash release is enabled when 85 % of the selected energy is available. Please note, however, that the ready indicator is activated only at 100 % charge (chapter 6). The release is possible by means of a sync cable, photocell or the manual release key.  5.1 Photocell (cell)  The photocell can be switched on or off by using the “cell“ key (3). If it is activated the green LED lights up. After a flash sequence, an active photocell will be blocked and the green LED blinks. By pressing the "cell" key, the photocell is reactivated.  When releasing via the photocell, ensure that the receiving cell of the unit it not obstructed by obstacles.  Because the photocell is also infrared-sensitive, the compact unit can be wirelessly released in a simple way by using a small  flash unit with an infrared-permeable filter in front, mounted onto the camera. The VISATEC flash trigger is available under article number 56.200.00.  5.2 Sync sockets  The synchronous cable, art. no. 54.104.00, may be plugged into the sync sockets (1) or (2) to release flashes via cable. The appliance has a synchronous circuit with a low onload voltage to preserve your camera contact. The synchronous circuit may not be connected in parallel with products of other manufacturers which operate with high synchronous voltage.  5.3 “Test“ key    This “test“ key (5) allows manual release of the compact unit LOGOS. The respective LED lights up, when the flash voltage corresponds exactly to the selected value. During charging and discharging, the LED goes out and the output display blinks.   6.   Ready display  visual /audible  6.1  The visual ready display is the green LED at the “test“ key (5). It lights up only when the unit is at 100 % charge. After releasing the flash, this LED goes out until the unit is fully charged again.   - 8 -
 6.2  The audible ready signal „buzzer“ sounds when the unit is at 100 % charge. It may be switched on or off (chapter 7).  6.3  Audible fault signal  When the flash discharge fails, a warning signal of approx. 3 s duration will sound and the display (10) of the compact unit will flash.   7.   Setting additional functions  The “aux“ key (11) is used to set the additional functions. With repeated actuation of the key the following modes can be selected:  •  Setting proportionality level of the modelling light  LED “prop“ blinks (12) •  Define sequence (serial flashes)  LED “seq“ blinks (13) •  Charging dimmer switch on / off  LED “dim“ blinks (14) •  Buzzer switch on / off  LED “buz“ blinks (15) •  Slow charge switch on / off  LED “slow“ blinks (16) •  Setting appliance address / studio address  LED „unit“ blinks (18) •  Return to standard display  no LED blinks  After the setting has been performed, the standard display can be re-activated by pressing the “aux“ key (11) or automatically after a waiting period of approx. 30 seconds.  To select the additional functions and appliance settings, choose the respective LED (eg „charging dimmer switch on / off“). The digital display (10) will then show the actual selected value which can be changed by the energy control keys “up / down“ (8). If a setting is entered which deviates from the standard setting value or a function is activated, the respective LED will remain lit as a reminder after the display returns to standard (exception: functions “prop“ and “unit“).  If the unit is switched off and on again, it will be in the „standard display“ mode. Previously set additional functions are retained.  7.1  Setting proportionality level of the modelling light (prop)  The proportionality level of the modelling light can be selected by briefly pressing the energy control keys “up / down“ (8). With repeated actuation of the key the following modes can be set, each shown respectively on the digital display (10): P, P1, P2, P3, P4, P5, HI, LO.   - 9 -
 7.2  Sequence (serial flashes) (seq)  This function allows to set a defined number of flash discharges from 1 to 50. By briefly pressing the energy control keys “up / down“ (8), the required number of flashes can be selected. With a long pressure on the energy control keys “up / down“ (8), the setting changes in intervals of ten. Each release signal triggers the selected number of flashes. A current sequence can be aborted by a long pressure on the energy control keys “up / down“ (8) or by switching off and on again the unit.  7.3  Charging dimmer / boost function (dim)  The “dim“ function can be switched on or off (on/--) by briefly pressing the energy control keys “up / down“ (8). When switching on the “dim“ function with the modelling light on (green LED of the “mod“ key (4) lights up), the modelling light switches off while charging takes place. This feature allows visual flash control, to fade out the modelling light during flash sequences or to reduce the current load on weak mains.  If the “dim“ function is activated when the modelling light is switched off (green LED of the “mod“ key (4)  is off), the boost function will be activated. In this mode, the modelling light remains on as a visual flash monitor during charging.  7.4  Buzzer switch on / off (buz)  The ready buzzer signals when the unit is at 100 % charge. The buzzer is switched on or off (on/--) by briefly pressing the energy control keys “up / down“ (8). The warning signal also functions with the buzzer switched off.  7.5  Slow charge switch on / off (slow)  In case of weak mains power supply lines, charging time may be extended to approx. double the standard value. The slow charge mode is switched on or off (on/--) by briefly pressing the energy control keys “up / down“ (8).  7.6  Studio / appliance address (unit)  The compact units LOGOS are also available as versions with built-in RFS Interface (Radio  Frequency  System). For remote control respectively flash release via radio, an individual appliance address and a studio desk top (remote control channel) can be assigned to each RFS unit by means of the function “unit“ (18).  To carry out the settings, dial the LED „unit“ using the “aux“ key (11). The digital display (10) shows the letter “U“, followed by an appliance number between 1 and 8. By briefly pressing the energy control keys “up / down“ (8), the required value can be selected. When pressing again  the “aux“ key (11), the digital display (10) shows the letter “C“, followed by a studio number between 1 and 8. By briefly pressing the energy control keys “up / down“ (8), the required value can be selected.     - 10 -
8.   Flash tube  The flash tube is coated to ensure an optimal colour temperature. For your security, only original flash tubes must be used. For safety reasons, never operate a unit without protecting glass in place.  If the compact unit LOGOS 800 is used for longer flash sequences, we recommend to employ the flash tube for LOGOS 1600 / SOLO 1600B - Art. no. 54.301.00.  8.1  Replacing the flash tube  1.)  To replace the flash tube, discharge the unit by flashes, disconnect it from power supply and let it cool off for ten minutes (to discharge the flash capacitors).  2.)   Remove the protecting glass.  3.)   First pull out the ignition cable and then the flash tube (do not touch the flash tube with bare hands).  4.)  Insert the new flash tube.  5.)   Re-insert the ignition cable.  6.)   Replace the protecting glass.  7.)   Connect the unit to the power supply, now it is ready for use again.  9.   Protecting glass  For safety reasons, never operate a unit without protecting glass in place.   10.  Fuse  The fuse (7) is located on the rear of the unit. Sand-filled fuses with value 3.15 AF may only be used (sand-filled fuses can be identified by their opaque fuse container). Using wrong fuses is dangerous; it may cause the halogen lamp to burst. Original VISATEC replacement lamps are therefore delivered with the correct fuse.   11.  Basic settings ex work  The basic settings ex work can be viewed and in some instances changed with the following procedure:  When the unit is switched on, simultaneously press the "mod" and "aux" keys for approx. 5 seconds (the LED array "prop" / “seq“ / "dim" / "buz" / “slow“ / "unit" blinks to indicate that you are in the programming mode).   - 11 -
 Additionally the LED of the „mod“ key is lit. The digital display shows the function number 0. The other function numbers can be selected by pressing the energy control keys “up / down“ (8).  By briefly pressing the „aux“ key, the digital display shows the actual value respectively the actual setting within the selected function number. The LED of the „mod“ key does not light up in this mode. Within the function numbers 1 and 7, the settings can be changed with the energy control keys “up / down“ (8). Concerning the function numbers 0 and 2 – 6, the different pairs of these multiple digit values can be shown by means of the energy control keys “up / down“ (8).  Return to normal operation by pressing (1 s) the „aux“ key, by switching the unit off and on again or automatically after a period of 20 seconds.   Function number Meaning and possible settings  0 Program version: Standard display Program number:  after pressing the energy control “down“ key (8)  1  RFS Interface switch on / off (only for RFS versions): Setting ex work: "on" (LED “unit“ is lit). With  RFS Interface switched off, the digital display shows the value “--“.  2 Flash counter: Figure group in the display: xxxxXX = Standard display Figure group in the display: xxXXxx = after pressing the energy    control “down“ key (8) Figure group in the display: XXxxxx = after pressing the energy    control “down“ key (8)  3 Series number of the unit: Figure group in the display: xxXX  4 Series number of the unit: Figure group in the display: XXxx  5 Production date of the unit: Figure group in the display: xxXX = month  6 Production date of the unit: Figure group in the display: XXxx = year  7  Reduction of the modelling light: Setting ex works: "off" (--) The activation of this function is recommended on power mains with great fluctuations. The voltage for the modelling lamp is reduced (light output ./. 1/3 f-stop), which results in a longer service life of the halogen lamp. If this function is activated, the digital display shows the value “on“.    - 12 -
12. Protective facilities / Fault indication  12.1 Cooling fan  The cooling of flash tube, modelling lamp and internal electronics is effected by a cooling fan. It also runs when the modelling light is turned off. The cooling works on two levels, the fan runs smoothly when small flash sequences are effected. With longer flash sequences, the cooling fan switches to the higher level.  12.2 Display “th“    If excessively high temperatures build up inside despite the fan cooling, the charge mode will be blocked and a long audible signal will be generated. The modelling light is blocked as well for about 6 minutes. The digital display shows the indication "th" during the cooling period. The cooling process is accelerated by the fan which is still in operation.  12.3 Display “A1“    The unit is equipped with an automatic afterglow blockout. If the flash tube exhibits (e.g. at the end of its service life) afterglow, this blockout will block further charging to prevent consequential damage. This status is also discernible by the ready display, which is no longer green. The blockout can be cancelled by switching the unit off and on again.  Attention: Do not switch off the unit during the cooling period! If the unit is switched off too early, only a small number of flashes can be effected until the next blockout, when switching on again the unit, despite a long break, because the processor could not completely pursue the cooling process.  12.4 Display “A2“    This indication is shown, when the unit is overcharging. Switch off the unit and switch it on again after a few minutes. If this fault continues to exist, please contact an after-sales service centre.  12.5  Acoustic flash monitoring    At the end of their service life, flash tubes often have triggering interruptions. This fault is indicated by an audible, intermittent signal. The signal disappears when the flash tube flashes properly again or the unit is switched off.  12.6  Monitoring of the modelling light  If the compact units LOGOS are connected to 200 V – 240 V mains voltage, after previously having been operated on 100 V - 120 V mains voltage, they will release an audible signal and the modelling light will blink at a safely reduced voltage. This function serves as a reminder that the modelling lamp must be exchanged, and also to protect against damage of the lamp. Switch the unit off and on again to return to standard operation.    - 13 -
 13. Car battery converter  If no mains power is available, the 12 V car battery converter can be used to charge the unit (only for 230 V units). The modelling light cannot be used in this operating mode (excessive load on the battery) and must be removed.  •  Before removing respectively replacing the flash tube and the modelling lamp, switch off the modelling light, discharge the unit, then immediately disconnect it from mains supply and let it cool down for 10 minutes. •  Remove the flash tube. •  Remove the halogen lamp (modelling). •  Connect the converter with the + and – connector clamps to the 12 V car battery. •  Connect the unit to the converter and switch on the unit and the converter. •  Switch off the converter during pauses after flash work. Charge battery if needed by allowing the car engine to run. One compact unit LOGOS can be connected to one converter. Approx. 200 flashes of 300 J respectively 100 flashes of 600 J are possible with a fully charged battery.   14. Mounting  The stand adapter is located below the housing. The adapter is designed for standard broncolor® bolts (12 mm) and Manfrotto® pins (16 mm).  Make sure the unit is firmly attached to the stand before operating. The click-stops of the locking handle can be adjusted by pulling it out.  A bracket for suspended mounting is available under art. no. 35.228.00. If the unit should be suspended without bracket on a broncolor® bolt, the enclosed locking pin must be screwed into the lower part of the stand adapter. This is not required for stand mounting. A safety cable must be installed whenever the unit is suspended.   15. Umbrella holder  Diffusing and reflex umbrellas are used in conjunction with the umbrella reflector (art. no. 53.457.00). The umbrella bar is inserted into the special holder in the stand adapter.    - 14 -
 16. Accessories  The compact unit LOGOS is equipped with an interlocking VISATEC bajonet, which permits a 360° rotation of the mounted light shapers. For this reason, the whole range of  VISATEC accessories assortment is at your disposal. You will find the complete overall view in the VISATEC system catalogue.  16.1  Mounting of barn doors  The barn doors are attached onto the fastening braces on the reflector.   17. Service / repair  Your VISATEC compact unit is a precision device which will work for many years without malfunction if you take proper care of it. If nevertheless malfunctions do arise, please do not attempt to open the unit to repair it yourself. Even when the unit is switched off, dangerous voltages may remain within the interior of the device. Always leave service and repairs to the VISATEC after-sales service.   - 15 -
 18. Technical data   LOGOS 800  LOGOS 1600     Flash energy  300 J (100 V: 250 J)  600 J (100 V: 500 J) F-stop at 1 m distance 100 ISO, standard reflector 45 (100 V: 32 7/10)  64  (100 V: 45 7/10) Flash duration t 0.5 (t 0.1)  1/800 s (1/250 s) with mains voltage 110 – 240 V 1/600 s (1/150 s) with mains voltage 110 – 240 V   Flash duration with mains voltage 100 V: approx. 20% longer Charging time (for 100 % of the  selected energy) 230 V / 50 Hz: 0,3 – 1,2 s 120 V / 60 Hz: 0,3 – 1,2 s 100 V / 50 Hz: 0,3 – 1,5 s 230 V / 50 Hz: 0,5 – 1,9 s 120 V / 60 Hz: 0,4 – 2,0 s 100 V / 50 Hz: 0,4 – 3,0 s   Can be switched to slow charge mode  With LOGOS 800 / 1600 – version 230 V (bi-voltage): Automatic adaptation to the respective mains voltage Attention: The above mentioned charging times for 100 – 120 V do not apply   to the bi-voltage version. Controls Illuminated digital display, LED line and keyboard Control range of flash energy (Japan: ½ f-stop less) Over 4 f-stops in 1/10 f-stop increments (1:16) Modelling light  Halogen max. 150 W  Proportional to flash energy as well as “full” and “low” settings. Proportionality adjustable to all VISATEC flash systems and the different output levels (except VISATEC LITEPAC). Flash release  Manual release button, infrared-sensitive photocell (can be switched off), sync cable, VISATEC flash release Ready display  Visual and audible (can be switched off), signals when 100% of selected energy is reached Flash monitoring  Visual:  Dim and boost function for modelling light Audible: Buzzer Additional function  Sequence (serial flashes) up to 50 flashes Number of sync sockets  2 Stabilized flash voltage  +/- 1,5% Cooling Fan Standards  EC standard 73/23, UL 122 Power requirements  200-240 V / 50-60 Hz:  6 A 100-120 V / 50-60 Hz:  10 A Dimensions (L x W x H)  120 x 195 x 276 mm  120 x 195 x 276 mm Weight kg  2,6  3,1  Subject to change in the interest of product enhancement.    - 16 -
19. VISATEC LOGOS RFS / LOGOS plus    The compact units LOGOS are also available as unit versions with integrated 8 channel RFS Interface (Radio  Frequency  System). Each channel (studio) can control up to 8 units. This interface allows remote control respectively flash release by radio via transmitter RFS as well as by means of a transceiver RFS via PC or Macintosh computer. When controlling via screen, 4 storage spaces for different lighting situations are at your disposal.   19.1  Modification to LOGOS RFS  There is the possibility, to modify LOGOS compact units later on with a RFS interface. The modification will be made by the customer service centre of our VISATEC agency in your country.   19.2 LOGOS plus Because of the laws in some countries, the use of the VISATEC radio system is not allowed. Therefore the LOGOS compact units are also available in the version LOGOS Plus (that means with cable remote control). Besides the cable connection between the compact unit and the computer, the applications with RFS is almost identical.   Attention: There is no camera transmitter available for LOGOS plus!   19.3 Technical data   LOGOS RFS  LOGOS plus Remote control  With integrated 8 channel RFS interface (Radio  Frequency  System) for the remote control of the unit by radio via transceiver RFS from PC or Macintosh computer. Each channel (studio) can control up to 8 units. With integrated interface for the remote control of the unit by cable from PC or Macintosh computer. Each channel (studio) can control up to 8 units. Flash release  Transmitter RFS, Transceiver RFS (beside the options in chapter 18)   analogue chapter 18 Operational distance outdoors up to 30 m  Length of the connection cable from the computer to the unit: 5m  Length of the connection cable between the units:  2,5 m Operational distance in closed rooms up to 20 m  see above Range  up to  300 m  see above Number of sync sockets  2  1 (the second sync socket is configured as connection for the computer cable)            - 17 -
  - 18 - Norms  UL 122, EC norms73/23, 89/336 and 99/5 ERM  EN 300 220-1,-3 EMC  EN 301 489-1,-3  EN 60950  EN 50371   FCC Part 15 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.   Subject to change in the interest of product enhancement.   20. Order numbers for diverse    spare parts / accessories  Halogen modelling lamp 150 W / 120 V  Art. no. 54.251.XX Halogen modelling lamp 150 W / 230 V  Art. no. 54.252.XX Flash tube, coated, to LOGOS 800 / SOLO 800B  Art. no. 54.300.00 Flash tube, coated, to LOGOS 1600 / SOLO 1600B  Art. no. 54.301.00 Protecting glass, clear  Art. no. 54.400.59 Fuse 3.15 AF  Art. no. 37137.00 Mains cable CH 200-240 V  Art. no. 39084.00 Mains cable USA 100-120 V  Art. no. 39085.00 Mains cable Europe 200-240 V  Art. no. 39086.00 Protection cap for transport, grey  Art. no. Z3620.00 Bracket for suspended mounting  Art. no. 35.228.00 12 V battery converter  Art. no. 36.450.XX
Operating instructions    b r o n c o l o r  Grafit A2/A4   Before use  We are pleased you have chosen a broncolor Grafit A power pack which is a high-quality product in every respect. If used properly, it will render you many years of good service.  Please read all the information contained in these operating instructions carefully. They contain important details on the use, safety and maintenance of the appliance. Keep these operating instructions in a safe place and pass them on to further users if necessary. Observe the safety instructions.   Contents   page Important safety instructions  2 Attention:  Read before starting up the power pack  3 Controls and displays  4 1.   Application Grafit A  6  2.  Start up           6  3.   Energy control  6 4.   Lamp base outlets  7 5.  Modelling light  7 6.   Release and remote control  10 7.   Flash ready signals visual/audible  11 8.   Setting additional functions  12 9. Protective facilities / Fault indication  17 10. Lamp bases  18 11.  Preset sequence (preprogr. series of flashes)  21 12.   Technical data  26 13.   Grafit A RFS / Grafit A plus  27 1
Important safety instructions   When using your photographic equipment, basic safety precautions should always be followed, including the following:    1.  Read and understand all instructions before using.   2.  Close supervision is necessary when any appliance is used near children. Do not leave appliance unattended while in use.   3.  Care must be taken as burns can occur from touching hot parts.   4.  Do not operate appliance with a damaged cable or if the appliance has been dropped or damaged - until it has been examined by a qualified service person.   5.  Position the cable so that it will not be tripped over, pulled, or contact hot surfaces.    6.   If an extension cable is necessary, a cable with a current rating at least equal to that of the appliance should be used. Cables rated for less amperage than the appliance may overheat. When using a cable reel, it must be completely unrolled before use to prevent overheating of the cable.   7.  When plugging in and unplugging lamp plugs, the unit must be switched off.    8.  Always unplug appliance from electrical socket before cleaning and servicing and when not in use. Never jerk cable to pull the plug from the socket. Grasp plug and pull to disconnect.   9.  Let appliance and connected lamp bases cool completely before putting away.   10.   When putting away and winding up cables, take care they do not come into contact with hot parts of the appliance.   11.  To reduce risk of electric shock, do not immerse this appliance in water or other liquids.   12.  To reduce the risk of electric shock, do not open this appliance, but take it to a qualified service person when service or repair work is required. Incorrect reassembly can cause electric shock when the appliance is used subsequently.   13.  The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire, electric shock, or injury to persons.   14.  Connect this appliance to a grounded socket.    2
Attention:  Read before starting up the power pack   -  Prior to replacing fuses, light bulbs or flash tubes, discharge the power pack and disconnectfrom power supply. Disconnect the lamp base from the power pack.  -  These units are designed for use in dry conditions. Protect them from water and fromexcessive exposure to dust.  -  The units are not suitable for use in an environment where there is a risk of explosion.  -  The accessories mounted onto the lamp bases may heat up to high temperatures underspecific conditions. Handle with care!  -  With due allowance for heat radiation, lamp bases with more than 100 W modelling lightmay be directed against inflammable surfaces only at a minimum distance of 1 m.  -  For safety reasons, never operate the lamps without the protecting glassin place.  -  Flash light contains, similar to sunlight, a specific portion of UV light. The undesirable sideeffects on skin and eyes are considerably reduced by using flash tubes and glass covers with a UV coating. Without these or other protective filters, use with extreme care whenshooting.  -  Even when disconnected from the power supply, dangerous voltages may remain inside theunit. For this reason units should be opened by authorized broncolor service persons only.  -  Do not block the cooling louvers on the unit.  -  broncolor power packs and lamp bases meet an extremely high safety standard. Whenconnecting  broncolor products to other manufacturers' products, integrated safety measures may become ineffective. Due to different design features and contact assignmentof the lamp plugs of other brands, the user himself/herself may even be at risk. We offer noguarantee and accept no liability for damages which may be caused by this type of usage.  3
Controls and displays   1.   Mains switch 2.   Voltage selector 110V/230V 3.   Circuit breaker 4.   Sync socket 5.   Connection socket for mains cable 6.1   Outlet I 6.2   Outlet II 6.3   Outlet III 7.1   Lamp base switch 1, on/off 7.2   Lamp base switch 2, on/off 7.3   Lamp base switch 3, on/off 8.   Power selector per lamp +/- 9.   Digital power display per lamp 10.   Master power selector +/- 11.   Photocell 12.   Digital master power display 13.   Photocell on/off 14.   IR receiver cell 15.  IR receiver and/or RFS-interface on/off 16.   Modelling light on/off 17.   Test key, ready light green 18.   4 line LCD display 19.   Cursor up/down 20.   Reset key 21.   Auxiliary functions setting key   4
   5
1. Application Grafit A  This mains (AC-line) supplied studio flash unit is designed for professional photography only. For your safety use a three-wire extension cable when required.     2.   Start up  2.1   Mains voltage / voltage selector    Set the unit to the required mains voltage by turning voltage switch (2) with a coin or screwdriver.   The unit is designed for 230V, 120V or 100V according to voltage of country. If a different voltage than the original one is selected, the following limitations come into force:  230V unit on 120V:    Can only be operated with power up to level 9.   The charging time becomes longer.  120V unit on 230V:   The recycling time becomes longer  100V unit on 230V:   The recycling time becomes longer    2.2   Earthed Mains (AC-line)    Connect unit to current supply always using earthed mains plug.     2.3   Start up    Use the mains (AC-line) switch (1) to power-up unit. During the charging process the digital master power display (12) flashes, after which, it becomes continuous.     3.   Energy control  3.1   Grafit A2/A4  Use the "+/-" keys (10) to control the flash energy (flash intensity) on both main outlets (I, II) within a range of 6 7/10 f-stops, and when including reserve lamp III within a range of 4 f-stops. A value of 10 in the display indicates maximum intensity, 3.3 resp. 6 minimum. Whole numbers are full f-stop intervals, decimals indicate 1/10 f-stop steps. Brief pressure on the "+/-" keys (7.1, 7.2, 7.3, 10) runs the power up (or down) by a 1/10 f-stop interval, prolonged pressure by a full f-stop. The display (12) then blinks until charging or discharging has stabilized the new level.   6
3.2  1/10 or 1/3 f-stop increments control The fractional power level adjustment can be programmed for 1/10 or 1/3 f-stop intervals; the units are factory set to 1/10 steps. For reprogramming to 1/3 steps see chapter 7.   3.3   Individual energy distribution (Asymmetry)  The Grafit A power packs incorporate a circuit for selectively distributing the power between the lamp base outlets. If outlet III is used as well, it has the highest flash energy. To ensure an optimum quality of colour temperature it is recommended to limit the maximum asymmetry of the flash power between each individual lamp outlet to three f-stops. The unit indicates this limitation if applicable.    4.   Lamp base outlets    Lamp base outlets of the Grafit units are marked with the Roman numerals I to III.    All outlets may be switched individually (7.1, 7.2, 7.3). The LED (9) indicates the flash energy for each separate lamp base. For newly connected lamp bases, the connection will be automatically activated.    5.   Modelling light  5.1  The "mod" key (16) switches on the modelling lamps for all connected lamp bases. When switched on, the green LED (Liquid Electronic Display) lights up. Lamp bases also have an additional modelling lamp switch. You may also operate the modelling light proportionally  (Chapter 5.2) and adapt it to the various maximum outputs of broncolor power packs.   5.2 Proportionality    In chapter 8 is an explanation of how to set the various operating modes (modelling light proportionality).     Stages prop1, prop2, prop3, prop4 and prop5 are used to adapt the modelling light brightness of power packs with different output. The setting "modelling light proportional" duly allows for the output set, the number of lamp bases as well as an asymmetrical energy distribution.    7
Proportionality is guaranteed if the identical operating mode has been set for all power packs. The higher the digit, the brighter the modelling light.   The following operating modes are possible:  "prop1"  This level allows matching of the Grafit A units to the proportional control of the Pulso 8 power pack.  "prop2"  Proportional modelling light - brightest level with Grafit A4.  "prop3"   Proportional modelling light - brightest level with Grafit A2.  "prop4/5"  If you use a power pack with less power it is known that the halogen modelling light is relatively weak and yellowish. To solve this problem the power packs have been provided with two additional proportional light levels. If the power of the Grafit A4 is lower than "8.0" and of the Grafit  A2 lower than "9.0" you can increase the modelling light immensely with "prop4".     If the power of the Grafit A4 is lower than "7.0" and of the Grafit A2 lower than "8.0" you can increase the modelling light immensely with "prop5".  "P.Max."   When working only with one power pack in asymmetrical operation; using the level "P.Max.", the lamp base with the highest flash energy will be operated with full modelling light and the others will operate proportionally, corresponding to their selected power.    "full"   All lamp bases with full modelling light, independent of flash output, type of power pack and output distribution.  "economy"  Lighting level reduced for all lamps to reduce power consumption and extend the burning life of the tungsten-halogen lamps.   8
  Highest possible proportionality settings when combining packs of different output:     Nano 2 Topas A2 Grafit A2 Mobil  Nano A4 Topas A4 Grafit A4  Topas A8  Nano 2 Topas A2 Grafit A2  Mobil   P3 (or “P” when only using Nano 2)  P2  P1  Nano A4 Topas A4 Grafit A4   P2  P2 (or “P” when only using Nano A4)  P1   Topas A8  P1  P1  P1  Example 1:  A power pack Grafit A2 is operated together with a power pack Topas 8. The modelling light is proportional when both are set to mode "prop1".  Example 2:  A power pack Grafit A4 is operated together with a Grafit A2. The modelling light is proportional and highest possible when both are set to mode "prop2".   5.3  Reduced modelling light intensity    To avoid overloading the mains supply (AC-line), the 100-120 volt versions of the power packs reduce the modelling light intensity during charging. You can clear this factory-installed program if the power rating of the mains supply (AC-line) is sufficient - see key combinations in section 8.11 of the programming additional functions. When working with limited-power on the mains supplies (AC-line) you can also slow down the charging rate with the additional functions "slow charging" - this reduces the risk of blowing the supply fuses.   5.4  Modelling light switch on lamp base   The switch on the lamp bases permits selective lighting control with the modelling light. To avoid damage to the lamp filament, always switch off the modelling light before moving the lamp base.    9
6.   Release and remote control  6.1   Photocell (cell)     The photocell can be switched on or off by using the "cell" key (13). If it is activated the green LED lights up.    After a flash sequence, an active photocell will be blocked and the green LED blinks. By pressing the "cell" key the cell is reactivated.   6.2  Infrared receiver (ir)        The IR receiver can be switched on or off with the key “ir” (15). If the function is active, the green display lights up.  6.3   Infrared flash channels     You can trigger Grafit A power packs from broncolor infrared transmitters. These have two different channels. Setting instructions are stated in chapter 8.     If a power pack is triggered via infrared, the flash release follows with a time delay. If the setting of the IR channel is "all" the delay is 1/1000s, if the setting is selective it is 1/500s.    Important: when selective triggering is selected, all units in operation must be set to 1 or 2 (none on "all") and all the photocells should be switched off.   6.4 RFS interface     The RFS interface of the RFS version of the Grafit A units can be switched on or off as an additional function on the display by using the toggle key (21). (See chapter 8).   6.5  Sync socket (4)    Synchronous cables art. no. 34.111.00 or 34.112.00 may be plugged into the socket to release flashes via cable.    6.6  "Test" key (17)    This key (17) allows manual release of the power pack as soon as 70% of the set energy is available.   6.7 Remote Control    The remote control of the power pack Grafit A is operated by the Remote Control units Servor 3 and Servor d. If the power pack is switched to "stand-by" via the remote control unit, the decimal point of the main display will blink. The power pack can be "re-activated" either by the remote control unit or by pressing any button on the front panel.   10
 6.8  Remote control channels    Remote control by the means of servor or RFS may be performed via separate channels (studio workstations). This is explained in chapter 8.  6.9  Power pack addresses    Addresses will be assigned to each power pack for individual control. This is explained in chapter 8.     7.   Flash ready signals visual/audible  7.1   The visual ready signal is the green LED at the "test" key (17). It lights up only when the unit is fully charged. After a flash this LED goes out and lights up again when the unit is fully charged once more.   7.2   The audible signal "buzzer" sounds when the power capacitors are at 100% charge. It may be switched on or off. This is explained in chapter 8.    7.3  Audible fault signal   When the flash discharge fails, a warning signal of approx. 3s duration will sound and the display of the relevant lamp base will flash.    11
8.   Setting additional functions       Meaning of additional symbols on display    Indicates that one or several additional functions are active   !  Frames fault / alarm messages  ∗  Frames help text  #  Suggested default value for a certain setting   Help function          Advance the cursor to the “Additional” function and press the toggle-key v or ∧ for about 2 seconds to display an explanation of the function. The text begins and ends with “*” characters. To quit the help function, press the toggle switch again.         Function  possible settings       With the toggle-key v ∧ (19, on the front panel at the bottom left) the cursor can be moved up or down to select the various functions.    With the +/- key (21, on the front panel at the bottom right) different settings can be made.       8.1  Lamp 3, 2, 1     Display of the lamp power    - ..J   (joules)     - ..%   (percentage) 8.2  Modelling light     Choice of the proportional level    - prop1   (see as well chapter 4.)    - prop2     - prop3     - prop4     - prop5     - P.Max.     - full     - economy      12
 8.3  Sequence     In this mode you can select a number of flashes to be triggered  automatically.    - off - 2-50 (when t 0.1 (min), and  interval shorter 0,200s only   2-15)      8.4  t 0.1 (flash duration setting)     When operating lamp I or II, you can select the flash duration (t 0.1). Lamp III may not be used simultaneously. The unit always indicates the t 0.1 value of the lamp with the longest total flash duration.  - (min.) "flash duration"    On this setting the shortest flash duration will always be selected automatically regardless of the CTC control system.   -  (opt.) "flash duration"   The most suitable flash duration will automatically be selected to obtain the optimum colour temperature.    If the colour temperature is changed with the broncolor FCC, an arrow appears on the display next to the "(opt.)".      - 1/125 (only Grafit A4)   w/o CTC -  1/250   w/o CTC -  1/500   w/o CTC -  1/1000   w/o CTC -  1/2000     w/o CTC -  1/4000   w/o CTC -  1/6000   w/o CTC      8.5  Interval     This function allows to define the time between the flashes and therefore to delay the flash sequence. The interval setting cannot be used when: charging time is long and there are unsuitable supply voltages.   - off -  "delay time" (shortest charging   time - 50.00s)     13
 8.6  Delay of the first flash     You can delay triggering of the first flash by 0,01s - 50,00s.   - off -  0,01s - 50,00s      8.7  Alternate (ping-pong release)     This provides the option of determining the release sequence of 2 power packs, i.e., only one power pack triggers per IR signal, while the other is at rest.  This function allows performing faster photographic sequences.   - off - 1   (1. unit in succession) - 2   (2. unit in succession)      8.8  Preset sequence     Pre-programmed series of flashes with different intensity and different intervals (only outlets I+II). If this function is switched on the following settings are blocked: - output control -  power selector per lamp - lamp 1-3 - modelling light - sequence - t 0.1 - interval  -  alternate triggering of the flash  - No. 1 - No. 2 - No. 3 - etc. -  No. 16 (Details see chapter 11)     8.9  Charging time (slow charging)     In case of weak power supply lines, charging time may be extended.   - fast  -  slow       8.10  Memory 1 + 2     All setting can be stored and recalled later on.     -  Press the "+" key for 2s to store all settings (STORE) -  Press the "-" key for 2s to recall a previously stored setting (RCL)       14
 8.11  DIM     This function dims the modelling light during the recycling time (min. 0,5s). It allows a visual flash control and the extinction of the modelling light during sequences.   - ON -  OFF      8.12  Buzzer     The audible signal sounds when the power capacitors are 100% charged up. You can switch on resp. off the signal.    - ON -  OFF      8.13  IR channel     The Grafit power packs use two different channels for selective triggering of specific power packs or groups (studio workstations).   - all  (the unit will release on all IR signals) - 1  (the IR transmitter must be set correspondingly) - 2  (the IR transmitter must be set correspondingly)      8.14  IR channel / RFS interface     With Grafit A RFS power packs the IR-channel is defined in the additional functions “IR/RF” by briefly pressing the +/- (21).  Extended pressure on the +/- key switches the RFS function on resp. off.    IR- channel - all  (the unit will release on all IR signals) - 1  (the IR transmitter must be set correspondingly) - 2  (the IR transmitter must be set correspondingly)  RFS- Interface -  ON (RFS interface is switched on) -  -- (RFS interface is switched off)       8.15  Studio / Gen.      Studio = workstation Extended pressure on of the key -/+ sets the workstation .  01/20 Servor Enables the choice between studio  01 or 02.  RFS Enables the choice between studio 01 to 10       power pack  = power pack address  Brief pressure on the key -/+ sets the power pack address for remote control.  01/20 Servor Enables the choice between address 01 to 08. RFS enables the choice between address 01 to 10      8.16  Flash count   15
  Counts the already released flashes. By pressing extensively on the -/+ key the counter can be set back to 0.         8.17  Total count     Every flash discharge is counted.            8.18  Max. Display    1/10 f-stop The Grafit units can display flash output in 1/10 f-stop over a range of 6,7 f-stops. All Grafit power packs are factory-set to show values from 10 to 3.3. 10 indicates the maximum and 3.3 the minimum output level.   - 10 -  9 -  8 -  7    The display range can be shifted downwards in order to correspond with units of different power (Grafit A2/A4). The result will be the same number on the display for the same amount of selected power Grafit A2   value 8  =   1600J Grafit A4   value 9  =   3200J Pulso 8   value 10   =   6400J        10 9 8 7   10 9 9 8 8 8 7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3.3 3 3 3  2.3 2 2   1.3 1    0.3        1/3-f stop   - 1/3   For the display in 1/3 steps the power range is shown +9 to -11.         General:      With the remote control servor 3, we recommend retaining the standard setting (maximum energy = 10) since complications in the display in the command mode "all" may arise otherwise.          8.19  Store Aux       Grafit A power packs are factory-set to clear    - on 16
all programming function adjustments on loss of mains supply power, for whatever reason. This avoids operating errors on subsequent startup. - off      8.20  Language     To simplify the operation, you can select your language.   - G - E - F - etc.         8.21  Progr. Release       Shows the software release of the  EPROM.           8.22  Country     The country code is for sales and service.           8.23  Delivery date    First operation        8.24  Serial number      For service and sales        Reset key  -   When pressed briefly, the cursor jumps on the line "modelling light".   -   When pressed for 2s, the settings (sequence, t 0.1, interval, delay, alternate, preset sequence, charging time) are switched off.  -   When pressed for more than 10s, the unit is reset to the factory setting.   17
9.  Protective facilities / Fault indication    Fault / alarm messages are framed with "!" characters on each line.   9.1 Cooling    The cooling fan switches to a higher speed after some flashes    9.2  Thermal overheating display    To protect against overheating after extended series of flashes, the unit will power down for a number of minutes. At that stage, the following message will appear on the LCD display: "XX min. COOLING BREAK, DO NOT DISCONNECT" The cooling time is shortened if the unit remains connected and switched on.   9.3 Afterglow    In case of afterglow of an older flash tube, the LCD display will show the corresponding message.   9.4 Circuit breaker (3)  In the event of an electrical malfunction, the circuit breaker will automatically disconnect the power pack from the power source. The unit can be restarted by pressing the circuit breaker button. If it disconnects again immediately, the power pack must be serviced by an authorised technician.    10. Lamp bases    The following information applies to Pulso, Primo and Picolite lamp bases.    10.1  Replacing flash tubes    Prior to any change of the flash tube, the lamp base must be disconnected from the power pack!    Lamp bases use plug-in flash tubes.    18
  Normally the Pulso and Primo flash tube 1600 J have the UV-coating directly on the flash tube. In this case the protecting glass used must be clear. The protecting glasses as and the flash tubes 1600 J are available in the versions UVE coated (5500 K) and  uncoated (5900 K). Therefore, the Pulso and Primo lamp bases can be supplied upon request with an uncoated flash tube and a coated protecting glass.     The flash tubes 3200 J for Pulso and Primo lamp bases as well as the flash tubes for Picolite are available only uncoated for thermal reasons. Therefore those lamps must be used with a UV-coated protecting glass.     The flash tube and protecting glass of the Pulso 8 lamp bases form one module.     10.1.1  Pulso-/Primo lamp bases up to 3200 J  To change the flash tube, carefully pull off the protecting glass. Pull straight, without tilting. Lamp bases manufactured from 1996 on, have the upper of the three springs holding the protecting glass differently shaped to provide a better hold. When removing the protecting glass it is necessary to first pull out the glass from the bottom springs. Release the contact spring (only Primo lamp) and again be sure to pull the flash tube straight along the lamp base axis.   When inserting the tube check that the ceramic base is fully pushed back in, and that for the Primo lamp bases the contact spring rests on the inside ignition wire.  Then the protecting glass has to be re-inserted in front of the modelling light and flash tube. It is held by three springs. Because the Primo lamp base can be operated with 1600 J flash tubes as well as with 3200 J flash tubes, a corresponding warning sign is supplied with each flash tube. Please stick this warning sign on the lamp base plug when inserting the flash tube.  10.1.2  Pulso 8 lamp base    The flash tube is only available with a built-in protecting glass. When exchanging the flash tubes or replacing the modelling lamp, hold the flash tube carefully on the protecting glass and pull out in axial direction. When inserting the flash tube check that the ceramic base is fully pushed back in.      10.1.3  Picolite small lamp  This small lamp has a plug-in flash tube with spring fastener. For thermal reasons the UV-coating is on the protecting glass. The protecting glass is available in the versions UVE-coated (5500 K) and UVE-matt coated (5500 K).   To change the flash tube release the spring ring and remove the protecting glass. The flash tube must be pulled out straight along the lamp base axis. When inserting the tube be sure that it is fully pushed in. Finally replace the protecting glass and fasten with the spring ring.        10.2  Changing the halogen lamp  19
  The halogen lamps are also plug-in or screw-in. Taking the lifespan into consideration, the halogen lamp should not be handled with bare hands.  Exchange of the halogen lamp is practically indentical to that of the flash tube.     The Primo and Picolite lamp base can be operated on the local mains (AC-Line) voltage (100V-240V) when a halogen lamp is used which corresponds to the voltage.    10.3 Cooling fan    A cooling fan in the lamp base cools the flash tube and modelling lamp. It also runs when the modelling lamp is turned off.   10.4 Thermal protection    The lamp bases have been fitted with an automatic thermal protection. Should the lamp base overheat (e.g. by impeding the flow of cooling air), the modelling light is shut off. Nevertheless you may continue producing flashes. The Picolite, however, has an additional thermal protection which limits the number of flashes.    10.5  Lamp base plugs    The lamp base plugs and sockets have mechanical interlocks to prevent inadvertent disconnection. When plugging in, ensure that those interlocks engage completely. To unplug, push down the locking spring below the cable guide and lift out the plug. The power pack must be switched off to plug-in and to unplug.     10.6 Reflectors    Primo and Pulso lamp bases have a bayonet fitting to take reflectors. The small lamp Picolite has an integrated reflector.    10.7 Fuses    Only sand-filled fuses of the type indicated on the type plate may be used; otherwise the halogen lamp may explode.           20
11.  Preset sequence (preprogr. series of flashes)  Table 1:  Grafit A2 with one lamp + Grafit A4 with one or two lamps  able 2: 1. flash 2. flash 3. flash 4.flashnumber delay energy delay energy delay energy delay energy10s 7.2 0.02s 8.220s 7.2 0.04s 8.230s 7.2 0.08s 8.240s 7.2 0.16s 8.250s 7.2 0.02s 7.2 0.04s 8.260s 7.2 0.04s 7.2 0.08s 8.270s 7.2 0.08s 7.2 0.16s 8.280s 7.2 0.16s 7.2 0.32s 8.290s 5.2 0.02s 6.2 0.04s 7.2 0.06s 8.210 0s 5.2 0.04s 6.2 0.08s 7.2 0.12s 8.211 0s 5.2 0.08s 6.2 0.16s 7.2 0.24s 8.212 0s 5.2 0.16s 6.2 0.32s 7.2 0.48s 8.213 0s 5.2 0.02s 6.2 0.06s 7.2 0.14s 8.214 0s 5.2 0.04s 6.2 0.12s 7.2 0.28s 8.215 0s 5.2 0.08s 6.2 0.24s 7.2 0.56s 8.216 0s 5.2 0.16s 6.2 0.48s 7.2 1.12s 8.2 T  with two lamps Grafit A2 1. flash 2. flash 3. flash 4. flashnumber delay energy delay energy delay energy delay energy10s 7.2 0.02s 8.220s 7.2 0.04s 8.230s 7.2 0.08s 8.240s 7.2 0.16s 8.250s 7.2 0.02s 7.2 0.04s 8.260s 7.2 0.04s 7.2 0.08s 8.270s 7.2 0.08s 7.2 0.16s 8.280s 7.2 0.16s 7.2 0.32s 8.290s 6.1 0.02s 6.1 0.04s 7.1 0.06s 8.110 0s 6.1 0.04s 6.1 0.08s 7.1 0.12s 8.111 0s 6.1 0.08s 6.1 0.16s 7.1 0.24s 8.112 0s 6.1 0.16s 6.1 0.32s 7.1 0.48s 8.113 0s 6.1 0.02s 6.1 0.06s 7.1 0.14s 8.114 0s 6.1 0.04s 6.1 0.12s 7.1 0.28s 8.115 0s 6.1 0.08s 6.1 0.24s 7.1 0.56s 8.116 0s 6.1 0.16s 6.1 0.48s 7.1 1.12s 8.1  21
22    These diagrams are provided as an explanation of table 1     Delay since moment of triggering         Energy / time     Nr. 0.00s0.02s0.04s0.06s0.08s0.10s0.12s0.14s0.16s0.18s0.20s0.22s0.24s0.26s0.28s0.30s0.32s0.34s0.36s0.38s0.40s0.42s0.44s0.46s0.48s0.50s0.52s0.54s7.2 8.227.2 8.237.2 8.247.2 8.257.2 7.2 8.267.2 7.2 8.287.2 7.2 8.295.26.27.28.211 5.26.27.28.212 5.26.27.28.13 5.2 6.2 7.2 8.214 5.2 6.2 7.2 8.215 5.2 6.2 7.216 5.2 6.2 7.2177.2 7.2 8.210 5.27.27.28.22
23               0.56s0.58s0.60s0.62s0.64s0.66s0.68s0.70s0.72s0.74s0.76s0.78s0.80s0.82s0.84s0.86s0.88s0.90s0.92s0.94s0.96s0.98s1.00s1.02s1.04s1.06s1.08s1.00s1.12s28.28.
   These diagrams are provided as an explanation of table 2 elay since moment of triggering    Energy / time              D Nr. 0.00s0.02s0.04s0.06s0.08s0.10s0.12s0.14s0.16s0.18s0.20s0.22s0.24s0.26s0.28s0.30s0.32s0.34s0.36s0.38s0.40s0.42s0.44s0.46s0.48s0.50s0.52s0.54s7.2 8.227.2 8.237.2 8.247.2 8.257.2 7.2 8.267.2 7.2 8.277.2 7.2 8.287.2 7.2 8.296.1 6.1 7.1 8.110 6.1 6.1 7.1 8.111 6.1 6.1 7.1 8.112 6.1 6.1 7.1 8.113 6.1 6.1 7.1 8.114 6.1 6.1 7.1 8.115 6.1 6.1 7.116 6.1 6.1 7.11   24
            0.56s0.58s0.60s0.62s0.64s0.66s0.68s0.70s0.72s0.74s0.76s0.78s0.80s0.82s0.84s0.86s0.88s0.90s0.92s0.94s0.96s0.98s1.00s1.02s1.04s1.06s1.08s1.10s1.12s8.18.1      25
12.  Technical data    Grafit A2  Grafit A4    Flash energy  1600 J  3200 J f-ISstop at distance of 2 m (6 1/2 ft.), 100 O, reflector P70 64 2/10  90 2/10 Flash duration t 0.1 (t 0.5)  1/150 - 1/6000 s (1/450 - 1/10000 s) 1/80 - 1/6000 s 1/240 - 1/10000 s)   Flash duration and energy automatically regulated for optimum colour temperature. Flash duration can be preselected. Charging time (for 100% of selected energy) Version 1: 0.03 - 1.3 s (230 V) Version 2: 0.03 - 1.6 s (120 V) Version 3: 0.03 - 2.2 s (100 V) Version 1: 0.04 - 2.6 s (230 V) Version 2: 0.04 - 3.2 s (120 V) Version 3: 0.04 - 2.2 s (100 V)   Can be switched to slow charging mode for low-amperage power outlets Ready display  Visual and audible (can be switched off); signals when 100 % of selected energy is reached Lamp base outlets  2 main connectors with flash cut-off and 1 reserve connector Power output distribution  Symmetrical and variable asymmetrical Controls  Illuminated silicone keyboard, resistant to dust and scratches. Wireless remote control of all functions with infrared Servor e, alternatively, can be controlled with PC and Macintosh®. Control range  6 7/10 f-stops for main connectors, 4 f-stops for reserve connector, in 1/10 or 1/3 f-stop intervals Displayed simultaneously in joules and f-stops, joules switchable to percentage Colour temperature  CTC (Colour Temperature Control) for uniform or deliberately variable colour temperature with broncolor FCC (Flash Color Chronoscope) Modelling light  Halogen, max. 3 x 650 W at 200 - 240 V Halogen, max. 3 x 300 W at 100 - 120 V Proportional to flash energy and «full» and «low» settings. Proportionality adjustable to other broncolor power packs and their various output ranges Additional functions  Flash sequences, triggering delay, selectable flash duration, slow charging, ping-pong release, stroboscopic effects with one or more power packs, choice of two infrared channels; etc. User-friendly menu-driven design. Menu text available in multiple languages (German, English, French, etc.) Flash release  Manual release button, photocell (can be switched off) infrared receiver, sync cable, FCM 2, FCC, IRX2, IRQ No. of sync sockets  2 Stabilized flash voltage  +/- 0.5% Standards  UL 122, EC standard 73/23, 89/336 and 99/5UL 122 Power requirements  Version 1:  220-240V / 50Hz, switchable to 120V / 60 Hz, current consumption 10A, longer series with shorter charging times 16A. Version 2:  110-120V / 60Hz, switchable to 230V / 50Hz, current consumption 15A.  Version 3:  100V / 50Hz, switchable to 230V / 50Hz, current consumption 15A.Dimensions  288 x 180 x 311.5 mm  288 x 180 x 407.5 mm Weight kg  8  11        26
13. Grafit A RFS / Grafit A plus The power packs Grafit A are also available as an unit version with integrated 10 channel  RFS interface (Radio  Frequency  System). Each channel (Studio) can control up to 15 units. This face allows remote control respectively flash releases by radio via transmitter RFS as well as    PC or Macintosh compu en controlling via screen, 4 or different  ns are at your disp 13.1   Modification to Grafit A  interby means of a transceiver RFS via ter. Whstorage spaces f lighting situatio osal.    RFS    There is the possibility, to er pack face. The modification will be mad  in your try.    modify the Grafit A pow s later on with a RFS intere by the customer service centre of our broncolor agencycoun 13.2   Grafit A plus  some countries, the use of the broncolor radio system is noallo Grafit A power pack is also available in the version Grafit A plusputer, the application with RFS is almost identical.   era transmitter available for Grafit A plus!   Grafit A RFS  Grafit A plus itter RFS, transceiver RFS (besides tions in chapter 12) Analogue chapter  12 Remote control  -  Winterthe r   radio via transceiver RFS from  PC- or Macintosh computer. Each channel (Stud-  w l rd forthe GMacintosh computer. Each channel (Studio) can control up to 15 units.  ith integrated 10 channel RFS face (Radio  Frequency  System) for emote control of the unit by-  With integrated interface for the remote control of the unit by cable from PC or io) can control up to 15 units.   ith IR-manua emote control  servor  -  With IR- manual remote control servor  the control of the main functions of rafit A.  d for the control of the main functions of the Grafit A 50 m  Length of the connection cable from the com 5 m puter to the unit:    Because of the laws in t wed. Therefore the   (that means with cable remote control). Besides the cable connection between the power pack and the comAttention: there is no cam 13.3 Technical data  Flash release   Transmthe opOperational distance outdoors  Up to Length of the connection cable between the units:   2,5 m Operational distance in closed oms Up to 30 m  See above roRange  Up to 300 m  See above Number of sync sockets  1 (instead of the second sync socket there is the radio antenna)  1 (the second sync socket is configured as connection for the computer cable)  27
28 tandards  UL 122, EC-standards 73/23, 89/336 und 99/5 Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and is device must accept any interference received, including interference that may cause undesired operation. Technical data (continuation)  SERM  EN 300 220-1,-3 EMC  EN 301 489-1,-3  EN 60950  EN 50371   FCC Part 15 This device complies with part 15 of the FCC (2) ThChanges or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  ubject to change in the interest of product enhancement. S
Operating Instructions b r o n c o l o r          Topas A2/A4/A8   Before use  We are very pleased you have chosen a broncolor Topas compact unit which is a high-quality product in every respect. If used properly, it will render you many years of good service. Please read the information contained in these operating instructions carefully. They contain important details on the use, safety and maintenance of the appliance. Keep these operating instructions in a safe place and pass them on to further users if necessary. Observe the safety instructions.  Content Page Before use  1 Important safety instructions  2 Attention:  Read before starting up the power pack  3 Controls and displays  4 1.  Application Topas A  6 2.  Commissioning 6 3.  Energy control  7 4.  Lamp base outlets  10 5.  Modelling light  10 6.  Release and remote control  12 7.  Flash ready signals visual/audible  13 8.  Setting additional functions  14 9.  Basic settings ex works  15 10. Protective facilities / Fault indication  17 11.  Service/repair 18 13. Lamp bases  18 14.   Topas A RFS  21 15.   Technical data  22 1
Important safety instructions  This unit is designed for professional photography and is to be handled by skilled staff only.  When using your studio flash equipment, basic safety precautions should always be followed, including the following:  1.  Read and understand all instructions before using.  2.  Close supervision is necessary when any appliance is used near children. Do not leave appliance unattended while in use.  3.   Care must be taken as burns can occur from touching hot parts.  4.   Do not operate appliance with a damaged cable or if the appliance has been dropped or damaged – until it has been examined by a qualified service person.  5.   Position the cable so that it will not be tripped over, pulled, or contact hot surfaces.  6.   If an extension cable is necessary, a cable with a current rating at least equal to that of the appliance should be used. Cables rated for less amperage than the appliance may overheat. When using a cable reel, it must be completely unrolled before use to prevent overheating of the cable.   7.  The power pack must be switched off while plugging in or unplugging the lamp head plugs.  8.   Always unplug appliance from electrical socket before cleaning and servicing and when in use. Never jerk cable to pull plug from socket. Grasp plug and pull to disconnect.  9.   After use, let appliance as well as the connected lamp heads cool down completely before putting away.   10.   Put away and wind up  the cables so that they do not touch hot parts of appliances and lamps.  11.   To reduce the risk of electric shock, do not immerse this appliance in water or other liquids.  12.   To reduce the risk of electric shock, do not disassemble this appliance, but take it to a qualified serviceman when service or repair work is required. Incorrect reassembly can cause electric shock when the appliance is used subsequently.  13.   The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire, electric shock, or injury to persons.   14.   Connect this appliance to an earthed socket. 2
Attention:  Read before starting up the power pack   -  Prior to replacing fuses, modelling lamps or flash tubes, discharge the power packand disconnect from power supply. Disconnect the lamp base from the powerpack.  -  These units are designed for use in dry conditions. Protect them from water andfrom excessive exposure to dust.  -  The units are not suitable for use in an environment where there is a risk of explosion.  -  The accessories mounted onto the lamp bases may heat up to high temperaturesunder specific conditions. Handle with care!  -  With due allowance for heat radiation, lamp bases with more than 100 W modellinglight may be directed against inflammable surfaces only at a minimum distance of1 m.  -  For safety reasons, never operate the lamps without the protecting glassin place.  -  Flash light contains, similar to sunlight, a specific portion of UV light. Theundesirable side effects on skin and eyes are considerably reduced by using flashtubes and glass covers with a UV coating. Without these or other protective filters,use with extreme care when shooting.  -  Even when disconnected from the power supply, dangerous voltages may remaininside the unit. For this reason units should be opened by trained personnel only.  -  Do not block the cooling louvers on the unit.  -  broncolor power packs and lamp bases meet an extremely high safety standard.When connecting broncolor products to other manufacturers' products, integrated safety measures may become ineffective. Due to different design features andcontact assignment of the lamp plugs of other makes, the user himself/herself mayeven be at risk. We offer no guarantee and accept no liability for damages which may be caused by this type of usage. 3
 Controls and displays   1. Mains switch 2. Circuit breaker 3.  Keys for individual power distribution 4.  Slave cell on/off 5.  IR receiver on/off 6.  Modelling light on/off 7.  Test key, ready light green 8.  Additional functions (aux) 9.  Display symmetrical power distribution 10. Buzzer 11. Slow charge 12. Charging dimmer 13.  Operating mode modelling light 14.  IR receiver cell 15.  Digital power display per lamp 16. Slave cell 17.  Energy control up/down 18. Sync socket 19.1  Lamp base outlet 1 19.2  Lamp base outlet 2 20.  Connection socket for mains (AC-line) cable 4
5
 1.   Application Topas A  We are delighted that you have chosen the high quality product broncolor Topas A. With proper care it will render you many years of good service.  This mains (AC-line) supplied studio flash unit is designed for professional photography. For your safety, use a three-wire extension cable when required.    2.   Commissioning   2.1  Mains (AC-line) voltage  The power packs Topas A2 and Topas A4 automatically adapt to the respective mains (AC-line) voltage between 240 V and 100 V. When the unit is operated on 100 V the following limitations come into force:  - maximum flash energy Topas A2:  1200 J instead of 1600 J - maximum flash energy Topas A4:  2400 J instead of 3200 J - the flash duration is extended by about 20%    The Topas A8 Evolution power pack is designed only for mains voltage 200 – 240 V.  Bitte kontrollieren Sie, ob Ihre lokale Netzspannung mit den Angaben auf dem Typenschild des Gerätes übereinstimmt. Vergewissern Sie sich auch, dass die Halogenlampen (Einstelllicht) der angeschlossenen Leuchten ebenfalls mit der entsprechenden Netzspannung übereinstimmen.   2.2  Earthed Mains (AC-line)    Connect unit to current supply always using earthed mains plug.   2.3 Start-up    Use the mains (AC-line) switch (1) to power-up unit. During the charging process the digital power displays (15) of the two lamp outlets (1 and 2) flash, after which, they become continuous. Additionally the green ready light (7) is lit. 6
 3.   Energy control   3.1.  Variation of the energy  Use the "up/down" keys (17) to control the flash energy (flash intensity) on both lamp outlets (1 and 2) within a range of 5-stops. Whole numbers are full f-stop intervals, decimals indicate 1/10 f-stop steps.   Brief pressure on the "up/down" keys runs the power up (or down) by a 1/10 f-stop interval, prolonged pressure by a full f-stop. The energy displays (15) then blink until charging or discharging has stabilized the new level.   3.1.1  Topas A2 / Topas A4  The maximum flash energy corresponds to value 10, the minimum to value 5. It is possible to extend the control range by  Topas A2 to 6 f-stops and by Topas A4 to 6,5 f-stops (see chapter 9). Additionally the control range can be extended in the asymmetrical mode with following f-stops values by choosing the specific lamp outlet: by Topas A2: +1,3 f-stops and by Topas A4 +1,7 f-stops.   3.1.2  Topas A8 Evolution  The maximum flash energy corresponds to value 10, the minimum to value 6. It is possible to extend the control range by  5 f-stops (see chapter 9). Additionally the control range can be extended in the asymmetrical mode by one f-stop by choosing the specific lamp outlet or channel.     3.2  Symmetrical or individual energy distribution  Topas A power packs can be switched from symmetrical to individual (asymmetrical) energy distribution for each lamp base outlet. Press the keys "sym" or "asym" to select the required operating mode (3). The green control lamp of the display "sym" (9) lights up when the unit is in symmetrical operation. In the asymmetrical mode each lamp outlet is individually controllable. The only exception is the Topas A8 Evolution, which four lamp outlets are controlled in pairs over two individual, controllable channels.   7
3.2.1  Topas A2 on mains (AC-line) 110 V-240 V  If the unit is set to individual energy distribution the power is divided between the two lamp base outlets as follows:  Lamp outlet 1 = 60%. The control range of the flash energy extends between 1000 J down to 30 J (optional down to 15 J)  Lamp outlet 2 = 40%. The control range of the flash energy extends between 600 J down to 20 J (optional down to 10 J)   3.2.2  Topas A4 on mains (AC-line) 110 V - 240 V  If the unit is set to individual energy distribution the power is divided between the two lamp base outlets as follows:  Lamp outlet 1 = 70%. The control range of the flash energy extends between 2200 J down to 70 J (optional down to 25 J) Lamp outlet 2 = 30%. The control range of the flash energy extends between 1000 J down to 30 J (optional down to 10 J)   3.2.3  Topas A8 Evolution on mains (AC-line) 200 V -240 V  If the unit is set to individual energy distribution the power is divided between the two lamp base outlets I and II (1) respectively III and IV (2): Lamp base outlet 1: - with one lamp on lamp base outlet I or II = 50% - with two lamp on lamp base outlet I or II = 25% per outlet Lamp base outlet 2: - with one lamp on lamp base outlet III or IV = 50% - with two lamp on lamp base outlet III or IV = 25% per outlet  8
The control range of the flash energy extends per outlet: a) by using of a lamp base outlet:  up 3050 J down to 190 J (optional down to 95 J) b) by using both lamp base outlets:  up 1525 J down to 95 J (optional down to 50 J)  In asymmetrical mode, a maximum of 3050 J can be drawn from each lamp socket respectively channel by Topas A8 Evolution. Consequently Topas A Evolution power packs are in asymmetrical mode compatible with all broncolor lamp bases. Should the total power pack energy of 6100 J be triggered from one individual lamp base, a Pulso Twin lamp must be used, which, in comparison with a Pulso 8 lamp, results in a shorter flash duration.   If the power pack Topas A8 Evolution works in symmetrical mode,  the full power pack energy of 6100 J can be drawn from any socket. This requires the use of a Pulso 8 lamp however. For security reasons, smaller lamps are blocked in this operating mode. The advantage of the Pulso 8 lamp in comparison with the Twin lamp is its single and longer lamp cable, which is also suitable for large installations.   3.2.5  Operation Topas A2 on mains (AC-line) 100 V  If the unit is set to individual energy distribution the power is divided between the two lamp base outlets as follows: Lamp base outlet 1 = 60%. The control range of the flash energy extends between 700 J down to 45 J (optional down to 20 J) Lamp base outlet 2 = 40%. The control range of the flash energy extends between 500 J down to 30 J (optional down to 15 J)   3.2.6 Operation Topas A4 on mains (AC-line) 100 V  If the unit is set to individual energy distribution the power is divided between the two lamp base outlets as follows: Lamp base outlet 1 = 70%. The control range of the flash energy extends between 1700 J down to 105 J (optional bis 55 J) Lamp base outlet 2 = 30%. The control range of the flash energy extends between 700 J down to 45 J (optional bis 20 J)  9
 3.2.7  Stabilisation of the colour temperature   The power packs Topas A2 and Topas A4 are equipped with an automatic stabilisation of the colour temperature (CTC light). In this way the colour can be maintained, in symmetrical operation, at a constant temperature over a range of about 3 f-stops within +/- 150 K.    4.   Lamp base outlets  The two lamp base outlets (19.1 / 19.2) of the Topas A2 / A4 are marked with the numbers 1 and 2.   The four lamp base outlets (19.1 / 19.2 / 19.3 / 19.4) of the Topas A8 Evolution are defined in pairs with the numbers 1 and 2 on the two outlets. Each outlet respectively channel can be switched on individually. The luminous number display (15) show the flash energy of the respective lamp or channel.   The broncolor lamp assortment can be applied without limitations with Topas A2 and Topas A4. Only the lamp bases Pulso 8 can be used with Topas A8 Evolution in symmetrical mode.     5.   Modelling light   5.1 General  The "mod" key (6) switches on the modelling lamps for all connected lamp bases. When switched on, the green LED lights up. Lamp bases also have an additional modelling lamp switch.  Note:  Please note, the voltage of the modelling lamp must correspond with the mains voltage.    5.2 Proportionality    The brightness of the modelling light can be set proportionally to the flash intensity. To assure proportionality when operating units with different power output ratings, the units have various proportionality levels. Proportionality is guaranteed if the identical prop level has been set for all power packs. The higher the digit, the brighter the modelling light.  The following operating modes are possible:   10
„P1“  Proportional modelling light with broncolor power packs up to 6400 J   (= setting ex works for Topas A8) „P2“  Proportional modelling light with broncolor power packs up to 3200 J   (= setting ex works for Topas A4) „P3“  Proportional modelling light with broncolor power packs up to 1600 J (=setting ex works for Topas A2) „P4/5“  If a power pack is operated at a low output level, the halogen modelling light will be as known relatively weak and yellowish. To counteract this problem, the Topas is equipped with two additional modelling light proportionality levels: P4 for 800 J and less, P5 for 400 J and less. Thus the brightness of the modelling light can be increased. „HI“  All lamp bases operate at full modelling light power independent of flash output. This setting will allow video recordings using the modelling lamps. „LO“  Lighting level is reduced for all lamps independent of the flash output to reduce power consumption and extend the burning life of the halogen lamps.  Pressing the "mod" key (6) for 2 seconds when the modelling lamp is on will give direct access to the “HI” mode. To return to previous mode briefly press "mod" again.   Highest possible proportionality settings when combining devices of different output:      Topas A2 Grafit A2 Nano 2 Mobil Topas A4 Grafit A4 Nano A4 Topas A8 Evolution  Topas A2 Grafit A2 Nano 2 Mobil  P3  P2  P1  Topas A4 Grafit A4 Nano A4  P2  P2  P1  Topas A8 Evolution  P1 P1 P1   Example 1: A power pack Topas A2 is operated together with a power pack Topas A8 Evolution. The modelling light is proportional and most intense when both are set to mode "prop1".  Example 2: A power pack Topas A4 is operated together with Grafit A2. The modelling light is proportional and highest possible when both are set to mode "prop2".  11
 5.3  Modelling light switch on lamp base  The switch on the lamp bases permits selective lighting control with the modelling light. To avoid damage to the lamp filament, we recommend, always switch off the modelling light before moving the lamp base.    6.   Release and remote control  The flash release is enabled when 75% of the selected energy is available. Please note, however, that the ready indicator is activated only at 100% charge (chapter 7).  By triggering through the “cell” or infrared receiver (IR) you must be careful, that the infrared receiver of the device is not disturbed by hindrances.    6.1  Slave cell (cell)  The slave cell can be switched on or off by using the „cell“ (4). Is the function activated the green LED light(s) up. After a flash series an active cell is blocked, and the green  LED light(s) up. By pressing the „cell"  button, the blocking is over.   By triggering through the “cell” or infrared receiver (IR) you must be careful, that the infrared receiver of the device is not disturbed by hindrances.  6.2 Infrared-receiver (ir/rf)  The infrared receiver can be switched on and off by using the „ir/rf“ (5) key. If the function is activated the green LED light’s up.   By triggering through the “cell” or infrared receiver (IR) you must be careful, that the infrared receiver of the device is not disturbed by hindrances.   6.3  Infrared flash release channel  You can trigger Topas A power packs from broncolor infrared transmitters. If a power pack is triggered via infrared, the flash is released after a transmission delay of  1/1000 s.  12
 6.4   RFS-Interface (ir/rf)  The RFS interface by the power packs Topas A in RFS version is switched on/off through the key „ir/if“ (5) together with the infrared receiver. As option you can change the settings of this key (see chapter 9), if you wish to switch on/off both functions or only the infrared receiver. If one of these functions is activated, the green LED light(s) up.   6.5  Remote control channels  The remote control can only be used with the power packs Topas A RFS and operates by radio over the separate channels (studio working stations). This is explained in chapter 9.    6.6  Addresses power packs  The assignment of addresses by radio for each device is only possible with the power packs Topas A RFS. This allows the individual operation within the same studio working station. This is explained in chapter 9.    6.7 Sync socket  Synchronous cables art. no. 34.111.00 or 34.112.00 may be plugged into the socket to release flashes via cable.   6.8 „Test“ key   The key (7) allows manual release of the power pack (look chapter 7.1).    7.   Flash ready signals visual/audible   7.1  The visual ready signal is the green LED at the "test" key (7). It lights up only when the unit is fully charged with the regulated flash energy.   .  After a flash the energy displays (15) of the occupied lamb base outlets blink and the LED goes out and lights up again when the unit is fully charged once more.   13
 7.2  The audible signal "buzzer" sounds when the power capacitors are at 100% charge of the regulated flash energy. It may be switched on or off (chapter 8).    7.3  Audible fault signal    When the flash discharge fails, a warning signal of approx. 3s duration will sound and the display (15) of the respective lamp base will blink.     8.   Setting additional functions    The "aux" key (8) is used to select additional functions. Repeated actuation of the key toggles through the following display modes:    - Select proportionality level of the modelling light  LED “prop” blinks (13) - Set DIM    LED “dim” blinks (12) - Set slow charging    LED “slow” blinks (11) - Set buzzer    LED “buz” blinks (10)  - Return to standard display   no LED blinks  Nach erfolgter Einstellung Rückkehr zur Normalanzeige entweder durch Betätigen der Taste „aux“ (8) oder automatisch nach einer Wartezeit von 4 Sekunden.  To set the additional functions select the respective LED (example: "Set dim"). The digital display 2 (15) will then show the actual value which can be changed with the "up/down" key (17). If a setting is entered which deviates from the basic setting value, the respective LED will remain lit as a reminder after the display returns to standard (exception: function „prop“). If the unit is switched off and on again, it will be in the "standard display" mode. Previously set additional functions are retained.   8.1  Set proportionality level of the modelling light (prop)  The proportionality level of the modelling light can be selected by a brief pressure on the "up/down" key (17) of the lamp base switch 2. With repeated actuation of the key the following modes can be set, each shown respectively on the digital display 2 (15): P1, P2, P3, P4, P5, HI, LO.  14
 8.2  Set charging dimmer (dim)  The dim function can be switched on or off (on/--) by briefly pressing the “up/down” key (17) of outlet 2. If the dim function is switched on, the modelling light will extinguish when charging takes place. This feature can be used as a visual flash monitor and to reduce the current load on weak mains (AC-lines).   8.3  Set slow charge (slow)    In case of weak mains (AC-line) power supply lines, charging time may be extended to approx. double the standard value. The slow charge mode is switched on or off (on/--) by briefly pressing the “up/down” key (17) of the outlet 2.   8.4  Set buzzer (buz)    The ready buzzer sounds when the power capacitors are 100% charged up. The ready buzzer is switched on or off (on/--) by briefly pressing the “up/down” key (17) of the outlet 2. The alarm tone will remain audible even if the ready buzzer is switched off.    8.5  Sequences (series of flashes)    This function is selected with a prolonged pressure (1 s) on the key “test” and it permits to set a defined number of flash discharges from 1 to 8 (displays “n1” to “n8”). When the function is activated, i.e. a value between “n1” and “n8” is selected, the luminous display no. 1 (15) shows alternately the selected value of flash energy and the sequence of flashes. The function is inactivated again by selecting the value “n0”. Returning to the former operating mode, is effected by pressing the key “aux” (8).     9.   Basic settings ex works  The basic settings ex works can be viewed and in some instances changed with the following procedure:    Switch the unit on. Simultaneously press the "mod" (7) and "aux" (8) keys for 5 seconds. Digital display 2 (15) shows the selected function number and digital display 1 (15) shows the actual setting. Both values can be changed with the "up"/"down" key (17). 15
   The LED array will blink “cell”-“ir/rf”-“mod”-“test”-“sym” to indicate that you are in the programming mode. In functions number 0 and 3, pressing the "up"/"down" key of the digital display 1 (15) will toggle through the "prop", "dim" or "slow" green LED display in order to show different parts of a multi-digit display.   Function number  Meaning and possible settings  0  Program version ("prop" is lit) Program number ("dim" is lit)    1  Setting ex works: off „on“: Extended setting range of the flash energy. The detailed values are noticed in section 3.1 of chapter 3. The lowest f-stop level exhibits greater tolerances with regard to colour and repetitive precision. The flash release is not guaranteed for all lamp devices.    2  Setting ex works: off „off“: by pressing the key „ir/rf“ (5) only the infrared receiver can be switched on or off „on“: by pressing the key „ir/rf“ (5) the RFS interface together with the infrared receiver can be switched on or off  3  Flash counter:   "slow" is lit:  xxxxXX   "dim" is lit:  xxXXxx   "prop" is lit:  XXxxxx  4  Delivery date: Month  5  Delivery date: Year  6 Country code  7 Settings of the working studio working station: By pressing the keys „up/down“ (17) of the lamp display number 1 (15) you can address the working station („01“ to „10“). You can address up to 10 studio working stations.   8 Settings of the power pack address: By pressing the keys „up/down“ (17) of the lamp display number 1 (15) you can address the desired power pack („01“ to „10“). Per studio working station you can address up to 10 different devices.   Return to normal operation by pressing the "aux" key or by switching off and on again the unit.  16
 10.  Protective facilities / Fault indication  10.1 Display "th"    If excessively high temperatures build up inside despite the fan cooling effect, the charge mode will be blocked for a certain period of time and a long audible signal will be generated.     During the cool-down period "th" shows on the display of lamp base outlet 2 (15). The display of lamp base outlet 1 shows in "countdown" procedure the remaining duration of the cooling process. The fan continues to operate, thus accelerating the cooling effect.  Attention: Do not switch off the power pack while it is cooling down. If the power pack is switched off too early, it is likely, in spite of a long break, that only a few flashes are possible when switching on again the unit, because the processor has not been able to follow the entire cooling process.   10.2 Display "A1"    The unit is equipped with an automatic afterglow blockout. If the flash tube exhibits afterglow (for example at the end of its service life), this blockout will block further charging to prevent consequential damage. A1 will show on the display of lamp base outlet 2 (15). In this status, the ready lamp is no longer green. The blockout can be cancelled by switching the unit off and on again.   10.3 Circuit breaker  In the event of an electrical malfunction, the circuit breaker (2) will automatically disconnect the power pack from the power source. The unit can be restarted by pressing the circuit breaker button. If it disconnects again immediately, the power pack must be serviced by authorized service staff.   10.4  Monitoring of the modelling light    If the power pack is connected to 200-240 V mains (AC-line) voltage, after previously having been operated on 100-120 V mains voltage, it will release an audible signal and the modelling light will blink at a safely reduced voltage. This function serves as a reminder that the modelling lamp must be exchanged, and also to protect against bursting of the lamps. Switch the unit off and on again to return to standard operation.   10.5  Accustic control flash release   At the end of life the flash tubes often show flash trigger suppression. This damage is indicated by the device through a intermittent sound. The sound disappears, when the flash tube flashes again correctly or the device is switched off.   17
Note:   By Topas A8 Evolution the acoustic flash control release is active, if per channel one of the two lamp sockets are occupied.     11.  Service/repair  Your broncolor power pack is a precision device which will work for many years without malfunctions if you take proper care of it. If malfunctions do arise, please do not attempt to open the unit to repair it yourself. Even when the unit is shut off, dangerous voltages may remain within the interior of the device. Leave service and repairs to our broncolor repair service.    12.  Car battery converter  If no mains (AC-line) power is available, use the 12 V/220 V car battery converter.  The modelling light cannot be used in this mode (excessive load on battery) and must be removed.  -  Switch off modelling light and disconnect the lamp from the power pack. -  Connect converter to the 12-volt car battery with the + and – connector clamps. -  Connect unit to converter; switch on converter and unit. -  After flash work, switch off converter during pauses. Charge battery if needed by   allowing the car engine to run. -  1 Topas A can be connected to the converter.     13. Lamp bases    The following information applies to Pulso, Primo and Picolite lamp bases.   13.1  Replacing flash tubes  Prior to any change of the flash tube, the lamp base must be disconnected from the power pack!  18
   Lamp bases use plug-in flash tubes.  The Pulso, Primo and Unilite flash tubes 1600 J normally have the UV coating directly on the flash tube. In this case an uncoated protecting glass has to be used. The protecting glasses as well as the flash tubes 1600 J are available in the versions „UVE coated“ (5500 K) as well as uncoated (5900 K). For this reason the lamp bases Pulso and Primo can also be fitted with uncoated flash tubes and coated protecting glasses.     The flash tubes 3200 J for Pulso and Primo lamp bases as well as for the small lamp Picolite are for thermal reasons only available uncoated. Because of that an UV coated protecting glass must be used with these lamp bases.   The flash tube and protection glass of the Pulso 8 lamp base form one module.   13.1.1  Pulso / Primo and Unilite lamp bases up to 3200J  To change the flash tube, carefully pull off the protecting glass. Pull straight, without tilting. Lamp bases manufactured from 1996 on, have the upper of the three springs holding the protection glass differently shaped to provide a better hold. When removing the protection glass it is necessary to first release the glass from the bottom spring.  Release the contact spring (only Primo lamp) and again be sure to pull the flash tube straight along the lamp base axis. When inserting the tube check that the ceramic base is fully pushed back in, and that for the Primo lamp bases the contact spring rests on the internal ignition.  Finally, the protecting glass must be re-inserted before the modelling lamp and flash tube. It is held by three springs. As Primo lamp bases can be used with 1600 J tubes as well as 3200 J tubes, a corresponding warning sticker is supplied with each flash tube which must be affixed to the lamp plug when inserting the tube.   13.1.2  Pulso 8 Leuchte    The flash tube is available only with integrated protecting glass. When exchanging the flash tube or replacing the modelling lamp, hold the flash tube carefully on the protecting glass and pull out in an axial direction. When inserting the flash tube check that the ceramic base is fully pushed back in.  13.1.3  Small lamp Picolite    This small lamp has a plug-in flash tube with spring fastener. For thermal reasons the UV-coating is on the protecting glass. The protecting glass is available in the versions "UVE coated" (5500 K) and "UVE matt coated" (5500 K).  To change the flash tube release the spring ring and remove the protecting glass. The flash tube must be pulled out straight along the lamp base axis. When inserting the tube be sure that it is fully pushed in. Finally, replace the protecting glass and fasten with the spring-ring.  19
 13.2  Changing the halogen lamp  The halogen lamps are also plug-in or screw-in. Taking the lifespan into consideration, the halogen lamp should not be handled with bare hands. Exchange of the halogen lamp is practically identical to that of the flash tube.   The Primo and Picolite lamp base can be run on the local mains (AC-line) voltage (100-240 V) when a halogen lamp is used which corresponds to the voltage.   13.3 Cooling fan  A cooling fan in the lamp base cools the flash tube and modelling lamp. It also runs when the modelling lamp is turned off.   13.4 Thermal protection  The lamp bases have been fitted with an automatic thermal protection. Should the lamp base overheat (e.g. by impeding the flow of cooling air), the modelling light is shut off. Nevertheless you may continue producing flashes. The Picolite, however, has an additional thermal protection which limits the number of flashes.  13.5  Lamp base plugs  The lamp base plugs and sockets have mechanical interlocks to prevent inadvertent disconnection. When plugging in, ensure that those interlocks engage completely. To unplug, push down the locking spring below the cable guide and lift out the plug. The power pack must be switched off to plug-in and to unplug.   13.6 Reflectors  Pulso and Primo lamp bases have a bayonet fitting to attach reflectors. The Picolite small lamp has a built-in reflector.   13.7 Fuses  Only sand-filled fuses of the type indicated on the type plate may be used; otherwise the halogen lamp may burst. 20
 14.  Topas A RFS  The power packs Topas A are also available as unit version with integrated 10 channel RFS Interface (Radio  Frequency  System). Each channel (studio) can control up to 10 units. This interface allows remote control respectively flash release by radio via the transmitter RFS as well as by means of a transceiver RFS via PC or Macintosh computer. When controlling via screen, 4 storage spaces for different lighting situations are at your disposal.        14.1   Modification to Topas A RFS  There is the possibility, to modify Topas A power packs later on with a RFS interface. The modification will be made by the customer service centre of our broncolor agency in your country.     14.2   Topas A PLUS    Because of the laws in some countries, the use of the broncolor radio system is not allowed. Therefore the power packs Topas A are also available in the version Topas A Plus (that means with cable remote control). Besides the cable connection between the power pack and the computer, the application with RFS is almost identical.   Attention:           There is no camera transmitter available for Topas A Plus !    14.3 Technical data   Topas A RFS  Topas A plus Flash release   Transmitter RFS, transceiver RFS (besides the options in chapter 15) Analogue chapter  15 Remote control  -  With integrated 10 channel RFS interface (Radio  Frequency  System) for the remote control of the unit by  radio via transceiver RFS from  PC- or Macintosh computer. Each channel (Studio) can control up to 10 units. -  with IR-manual remote control  servor d for the control of the main functions of the Topas A.  -  With integrated interface for the remote control of the unit by cable from PC or Macintosh computer. Each channel (Studio) can control up to 10 units.   -  With IR- manual remote control servor d for the control of the main functions of the Topas A Operational distance outdoors  Up to 50 m  Length  of  the  connection  cable  from  the computer to the unit:  5 m Length of the connection cable between the units:   2,5 m Operational distance in closed rooms Up to 30 m  See above Range  Up to 300 m  See above Number of sync sockets  1 (instead of the second sync socket there is the radio antenna)  1 (the second sync socket is configured as connection for the computer cable)  21
 15. Technical data   Topas A2  Topas A4 Flash energy  1600J (Japan 1200J)  3200J (Japan 2400J) F-stop at distance of 2m 100ISO,reflector P70 64 2/10  90 2/10 Flash duration t 0.1 (t 0.5) with  1600J: 1/300s (1/1000s)  3200J:  1/150s (1/600s) 230 V / 120 V  1000J: 1/400s (1/1300s)  2200J:  1/180s (1/800s)     600J: 1/500s (1/1600s)  1000J:  1/250s (1/1300s) Charging time (for 100% of  selected energy) 230V, 120 V:  0,4 - 1,8s 100 V: 0,5 - 2s 230V, 120 V: 0,4 - 3,4s 100 V: 0,5 - 4s   Can be switched to slow charge mode   Automatic adaptation to the respective mains (AC-line) voltage Ready display  Visual and audible (can be switched off), signals when 100% of selected energy is reached Lamp base outlets  2  2 Power output distribution  Symmetrical and individual variable (asymmetrical) Controls  Fully illuminated silicone keyboard and LED display, as option functions can be controlled from PC or Macintosh through cable or radio  Control range of flash energy (Japan: ½ f-stop less) Topas A2: 5 f-stops in intervals of 1/10 (1:32); to switch to 6 f-stops (1:64) Topas A4: 5 f-stops intervals of 1/10 (1:32); To switch to 6.5 f-stops (1:90) By selecting the corresponding lamp outlet in asymmetrical mode additionally  1.3 f-stops by Topas A2, 1.7 f-stops by Topas A4 Maximum asymmetry  6.2 f-stops  5.6 f-stops Modelling light   Halogen max. 2 x 650 W at 200-240 V Halogen max. 2 x 300 W at 100-120 V Proportional to flash energy and „full“ and „low“ settings. Proportionality adjustable to other broncolor power packs and compact units and their various output ranges.  Flash release  Manual release button, photocell (can be switched off),  infrared receiver (can be switched off), sync cable, FCM 2, FCC, IRX2, IRQ or optionally RFS radio equipment Release control  Optical: Dim function of the modelling light, acoustic: buzzer Additional function  Sequences (flash series) No. of sync sockets  2 Stabilized flash voltage  +/- 1% Standards  UL 122, EC-standards 73/23, 89/336 and 99/5 ERM  EN 300 220-1,-3 EMC  EN 301 489-1,-3  EN 60950  EN 50371   FCC Part 15 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Power requirements   200-240 V / 50 Hz:  10 A 110-120 V / 50-60 Hz:  16 A 100 V / 50 Hz:  16 A Dimensions (L x B x H)  280 x 162,7 x 272 mm  280 x 162,7 x 322 mm Weight kg  5,8  8 22
Technical data (continuation)   Topas A8 Evolution with lamp base Pulso G, Primo, Unilite or Pulso Twin Topas A8 Evolution with Pulso lamp base 8 Flash energy  2 x 3050 J (4 x 1525 J)  6100 J F-stop at distance of 2m 100ISO, reflector P65 128 (Pulso Twin)  128 Flash duration t 0.1 (t 0.5)  3050J: 1/150s (1/600s)  6100J: 1/50s (1/230s) with 230 V  1525J: 1/300s (1/1200s)   Charging time  (for 100% of selected energy) 0,5 – 5,2s  0,5 – 5,2s   Can be switched to low charge mode   Topas A8 Evolution is previewed for a voltage of 200 – 240 V. Ready display  Visual and audible (can be switched off), signals when 100% of selected energy is reached Lamp base outlets  4 Power output distribution  Symmetrical and individual variable (asymmetrical) Controls  Fully illuminated silicone keyboard and LED display, as option functions can be controlled from PC or Macintosh through cable or radio  Control range of flash energy (Japan: ½ f-stop less) 4 f-stops in intervals 1/10 (1:16); can be switched to 5 f-stops (1:32). By selecting the corresponding lamp outlet in asymmetrical mode additionally 1 f-stop  Maximum asymmetry  5 f-stops Modelling light  Halogen max. 4 x 650 W by 200-240 V Proportional to flash energy and „full“ and „low“ settings. Proportionality adjustable to other broncolor power packs and compact units and their various output ranges. Flash release  Manual release button, photocell (can be switched off), infrared receiver (can be switched off), sync cable, FCM 2, FCC, IRX2, IRQ or optionally RFS radio equipment Release control  Optical: Dim function of the modelling light, acoustic: buzzer Additional function  Sequences (flash series) No. of sync. sockets  2 Stabilized flash voltage  +/- 1% Standards  UL 122, EC-standards 73/23, 89/336 and 99/5 ERM  EN 300 220-1,-3 EMC  EN 301 489-1,-3  EN 60950  EN 50371   FCC Part 15 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Power requirements  200-240 V / 50 Hz:  10 A 110-120 V / 50-60 Hz:  16 A 100 V / 50 Hz:  16 A Dimensions (L x B x H)  280 x 162,7 x 446 mm Weight kg  12,6  23
24 Technical data (continuation)  Standards  UL 122, EC-standards 73/23, 89/336 und 99/5 ERM  EN 300 220-1,-3 EMC  EN 301 489-1,-3  EN 60950  EN 50371   FCC Part 15 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  Subject to change in the interest of product enhancement.