  Page 1 of 21 2002-08-05 Release: 1.0  ID: ID020058               ScanIDTechnical Reports
ScanID    Release 1.0   Page 2 of 21 2002-08-05 ID: ID020058  1 INTRODUCTION 3 1.1 SYSTEM DESCRIPTION 3 2 IMPORTANT NOTES  4 3 HARDWARE 5 3.1 MEMBRANE KEYBOARD 6 3.2 TECHNICAL DATA 7 3.3 READING RANGES 8 3.4 CHARGE STATION 8 3.5 LICENSES AND CERTIFICATES / DECLARATION OF CONFORMITY 8 4 SOFTWARE 9 4.1 STANDARD SOFTWARE 9 4.2 ENTER THE MENU 10 4.2.1 Menu Settings  10 4.2.2 Brightness of the Display  10 4.2.3 Read Mode  11 4.2.4 Code Type  12 4.2.5 Page Select  12 4.2.6 HERMOS Menu  14 4.2.7 HERMOS Setup  15
ScanID    Release 1.0   Page 3 of 21 2002-08-05 ID: ID020058  1 Introduction  1.1 System Description  The ScanID hand held System is a high frequency identification system using the FM-transmission.  The basic item is a transponder working as a forgery-proof electronic identity disc.   The reading unit of the system sends an energy impulse via the antenna. The capacitor of the passive, battery-less transponder is charged by this impulse. After that, the transponder returns a signal with the stored data.  The data received by the transponder reader were checked in the µ-controller and send to the display.  The total reading cycle takes less than 100 ms.  As a sight-connection between transponder and reader is not absolutely necessary, the transponder can also be identified through non-metallic material.
ScanID    Release 1.0   Page 4 of 21 2002-08-05 ID: ID020058 2 Important Notes   This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1)  this device may not cause harmful interference , and 2)  this device must accept any interference received, including interference that may cause undesired operation.  CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorientate or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to     which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.                Please note when opening the device:  Static sensitive devices! Handle only at static safe work stations!
ScanID    Release 1.0   Page 5 of 21 2002-08-05 ID: ID020058   3  Hardware        The three load contacts are used to load the ScanID in the load station. The charging activity is shown on the display during the battery charging. The message ‘battery charged’ is shown in case of a full charged battery.Load contacts Membrane keyboardGraphic display
ScanID    Release 1.0   Page 6 of 21 2002-08-05 ID: ID020058  3.1 Membrane Keyboard  On/Off: This key switches on and off the reader. Push the key for more than 3 seconds to switch off.  Read: The ‘Read’ button is used to start the reading of the RF-tag data. In case of an unsuccessful reading, the handheld tries to read the RF tag up to 5 times  (default setting). In menu mode this key applies the entered code to enter the HERMOS menu.  Select: Normally this key is used to rotate between the different views of the tag information. Also it selects the marked menu items in the menu mode. In triggered mode the select button establishes a channel to the base station to transmit the data.   ESC: The ESC key steps out of the current menu up to the start screen.  Shift up and down: These buttons are used to scroll in the different menus.  Display: Graphic display with a resolution of 128x64 dots. The display can show 8 lines with 21 signs per line. The big font needs two lines per sign. The display memory can hold 32 lines with 21 signs which can be scrolled.
ScanID    Release 1.0   Page 7 of 21 2002-08-05 ID: ID020058  3.2  Technical Data    Parameter Value Operation temperature  0 to +50°C Stock temperature  -25 to +70 °C Permissible humidity @ 50C°  25 - 80 % Transmitter frequency LF  134.2 kHz Typical period of charging impulse  50ms Max. repeat of reading  8/s   Protection mode  IP 40 Housing material  ABS Weight   about 300g Li-Ion Accu  7,2 V / 1450 mAh  The accumulator is designed to read more than 2500 tags before you have to reload the ScanID. The ScanID turn off automatically after a adjustable time – typically 60 seconds. a1
ScanID    Release 1.0   Page 8 of 21 2002-08-05 ID: ID020058  3.3 Reading Ranges  The reading range is only valid for the transponder types Read only, Read/Write and for the first page of the multipage transponder. If you want to read another page than page 1 of a multipage transponder, the transponder requires the page number. In this case the reading range can be reduced.  Rod Antenna:    2,4 inch (Transponder parallel to antenna) Frame Antenna:    4 inch (Transponder parallel to axis of frame)   3.4 Charge Station  The charge station charges automatically the li-ion accumulator. The charging time is about 4 hours, a message  occurred on the display, when the device is charged. The supply voltage is 100-240V AC.  The housing of this charge station is made of ABS or high-grade steel. The charge station can be mounted horizontal or vertical.   3.5  Licenses and Certificates / Declaration of Conformity   •      •  FCC ID: N5GSID Compliance with: FCC Code of Federal Regulations, Part 15 Subpart C, Section §15.205 FCC Code of Federal Regulations, Part 15 Subpart C, Section §15.209
ScanID    Release 1.0   Page 9 of 21 2002-08-05 ID: ID020058 SCANID 1.5 LF   press Read FOUP:     FOUP1.1 Lot#:       lot01.456 Left:Text1 Righ:           Text2 Cent:     Text3 Next:        230045CD slot:1<  graphic  >25 Date:        02/05/15 4 Software  The software of  the ScanID is designed for a wide range of customer applications. It can also be developed for special applications and it is possible to update the firmware.  ! The red colored modes are not available for this type !  4.1 Standard Software   After switching on the ScanID the start page with the current software version is shown.           Press the ‚Read’ button to start the reading process of the ScanID. Therefore a transponder should be in the reading range of the antenna. The default number of attempts to read a transponder is 5 times.  Was the reading of the transponder data successfully, the data is shown on the display.  Example:
ScanID    Release 1.0   Page 10 of 21 2002-08-05 ID: ID020058 4.2  Enter the Menu  To switch into the menu mode press the two arrow buttons for more than 3 seconds.   4.2.1 Menu Settings  The menu items can be selected by the two cursor buttons. To activate a selected menu item press the ‚Select’ button.             4.2.2  Brightness of the Display  Select the wanted option (light or dark) with the cursor buttons. By pressing the ‚Select’ button you can increase or decrease the contrast of the display.             Settings Brightness Read Mode Code Type Page Select HERMOS menu  Brightness   Light Dark
ScanID    Release 1.0   Page 11 of 21 2002-08-05 ID: ID020058 4.2.3 Read Mode  The current mode is shown in the last line. To change the mode, select the requested mode with help of the cursor buttons and activate the mode by pressing the ‚Select’ button. The active mode is shown under item ‚active’.              auto. send:  After reading the FOUP-ID the ScanID establishes a connection to a host data base automatically and sends the FOUP-ID in message S3F81.  trig. send:   After reading the FOUP-ID the information is shown on the display. The operator can decide whether he establishes a connection to the host or not by pressing the ‚Select’ button or not.     not send:    After reading the FOUP-ID the information is shown on the display. The ScanID is not able to establish a connection to the host.     ! The red colored modes are not available for this type ! Read Mode  auto. send trig. send not send  active: not send
ScanID    Release 1.0   Page 12 of 21 2002-08-05 ID: ID020058 4.2.4 Code Type  The display of the current mode and the possibly change is similar to the described ‚Read Mode’.            If the current setting is ‚ASCII’, the FOUP-ID is shown in ASCII characters. In case of the setting is ‚HEX’, the 8 bytes of the ID are shown in hexadecimal format on the display.  Example:  ASCII: 00123456  Hex: 3030313233343536   4.2.5 Page Select  Select the different types of transponders or a special page of the transponder by using the cursor buttons. Apply the selection by pressing the ‚Select’ button. The active page is shown behind ‚active’. The option ‚Scan Tag’ reads always the first page of the transponder equal which type it is.           Code  Type   HEX ASCII  active: ASCII Page Select   Scan Tag  active: Scan
ScanID    Release 1.0   Page 13 of 21 2002-08-05 ID: ID020058  Scan:      The first page of a any transponder will be read.       (RO - Tags, RW - Tags, Multipage)  R/O Transponder:  Read a R/O transponder R/W Transponder:  Read a R/W transponder Multipage all:    all pages of a multipage transponder will be read       (only available in single device mode!) Multipage 1:    1. page of multipage will be read ... Multipage 17:    17. page of multipage will be read
ScanID    Release 1.0   Page 14 of 21 2002-08-05 ID: ID020058 4.2.6 HERMOS Menu  The menu item ‚announce to base’ initialize the DECT module of the ScanID to the address of the base station. Should the ScanID after an aborted firmware upload still be configured to the download station, this menu item can be used to configure the DECT module of the ScanID again to the base station. The ‚Download mode’ is used for the update of the ScanID software. If there is an online download station near by the ScanID, the ScanID can connect this download station to upload a new software.  After choosing the menu item ‚HERMOS settings’ the user will be requested to input a code. The code can be entered with the cursor buttons (number up and down) and the ‚Select’ button (step to next digit). The ‚Read’ button applies the code and in case of the right code the ScanID switches to the ‚HERMOS Setup’.  The ‘DECT commands’ item is used to configure the DECT module. The user can request the active DECT parameters and can change some settings of the module there.            ! The red colored modes are not available for this type !   HERMOS menu  announce to base Download mode HERMOS settings
ScanID    Release 1.0   Page 15 of 21 2002-08-05 ID: ID020058 4.2.7 HERMOS Setup  Select the wanted parameter with the cursor buttons. To change the value of the parameter, use the ‚Select’ button.  Readmode:  1 = read mode changeable,  0 = read mode fix Typemode:  1 = ScanID type adjustable, 0 = ScanID type fix  (dummy) Pagemode:  1 = type/page adjustable, 0 = typ/page fix Codemode:  1 = display mode adjustable, 0 = display mode fix Testmode:  0 .. 2; 0 = Off, 1 = test msg. 0x81,     2 = test msg 0x81 with sync.-reset Language:   0 = German,  1 = English MaxRepeat:  1 .. 9, number of repeated readings , default = 5 Baudrate:    baud rate of the module  (dummy) TimeOut5 :  1 .. 9, message timeout after X x 5s, default = 2 Æ 10s                  ! The red colored modes are not available for this type ! HERMOS Setup Readmode:  1 Typemode:  1 Pagemode:  1 Codemode:  1 Testmode:  0 Language:  0 MaxRepeat: 5 Baudrate:  3 TimeOut5:  2