Bryant 395Cav Users Manual
395CAV to the manual a13e9edf-d795-4eba-b836-9354b1021eec
2015-02-02
: Bryant Bryant-395Cav-Users-Manual-411962 bryant-395cav-users-manual-411962 bryant pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
395CAV ENERGY-EFFICIENT INDUCED-COMBUSTION DELUXE UPFLOW FURNACE Sizes 045 thru 155 Series H and J With a unique approach to induced-combustion design, a 40-in. tall cabinet, 4-pass heat exchanger, an inshot burner system, and its safety features, this furnace is without peer. The model 395CAV Deluxe Induced-Combustion Upflow Furnace achieves one of the highest Annual Fuel Utilization Efficiency (AFUE) ratings available in a noncondensing, induced-combustion furnace. Its ease and economy of installation, ease of serviceability, economical initial cost, and short payback time put it in a class well ahead of the competition. The model 395CAV Gas Furnace has the kind of overall performance needed in today’s homes. All models are GAMA efficiency rating certified and certified for use in California Air Quality Management Districts. FEATURES EFFICIENCY—The 395CAV Deluxe Induced-Combustion Gas Furnace provides the efficiency customers want with 80.0 percent AFUE. MEDIA FILTER CABINET—Enhanced indoor air quality in your home is made easier with our media filter cabinet—a standard accessory on all deluxe upflow furnaces. When installed as a part of your system, this cabinet allows for easy and convenient addition of a Bryant high-efficiency air filter. HOT SURFACE IGNITION—This field proven ignition system will save energy and improve reliability. ALUMINIZED HEAT EXCHANGER—The patented 4-pass heat exchanger is made of aluminized steel and backed by a 20-year Limited Warranty. INTELLIGENT CONTROL BOARD—The 395CAV Furnace has an intelligent control board with an LED status indicator light to ensure top furnace performance. This control board also has a self-test feature that enables the servicing technician to verify operation of the board itself, the inducer, the hot surface ignitor, both high- and low-speed blower operation, and the humidifier. The board also features a 3-amp fuse that protects the transformer and board. We guarantee the reliability of the control board with a 3-year Limited Warranty. 40-IN. HEIGHT—The 395CAV Deluxe Induced-Combustion Furnace with a 40-in. cabinet height simplifies installation in alcoves, attics, basements (ideal for short basement), closets, and utility rooms, especially with a high-efficiency cooling coil. PREPAINTED CABINET—The 395CAV uses prepainted sheet metal for the cabinet. This is the same high-quality finish found on refrigerators and other appliances today. We ensure its durability by using a galvanized steel substrate to provide superior rust protection. PATENTED BLOCKED VENT SAFEGUARD—Our inducedcombustion furnace has a patented blocked vent safeguard. The safeguard will stop furnace operation if the vent system becomes blocked or is not operating properly. An exclusive with the 395CAV Furnace. EASY INSTALLATION—The model 395CAV has many features that make installation easier: left or right gas and electrical connections, Molex blower speed selector, matching coil sizes, accessory low-voltage connections, and many more. QUIET OPERATION—A soft mount inducer assembly and slow opening gas valve improves sound level. Form No. PDS 395CAV.40.8 AIRFLOW 28 1⁄2″ 2 1⁄16″ VENT CONN 2 1⁄16″ DIA HOLE POWER ENTRY 7⁄8-IN. DIA ACCESSORY 7⁄8-IN. DIA POWER ENTRY 5 3⁄8″ 12 5⁄16″ 2 11⁄16″ 5 13⁄16″ 5 13⁄16″ 2 3⁄8″ 1 3⁄4-IN. DIA HOLE GAS ENTRY 1 1⁄2-IN. DIA R.H. GAS ENTRY 7⁄8-IN. DIA ACCESSORY 1⁄2-IN. DIA THERMOSTAT WIRE ENTRY 2 3⁄8″ DIA HOLE THERMOSTAT WIRE ENTRY 13⁄16″ OUTLET 1″ 5 3⁄8″ 1⁄2-IN. 19″ 13⁄16″ 1″ 7⁄8-IN. 39 7⁄8″ A D SIDE INLET SIDE INLET 141⁄2″ TYP 1″ 11⁄4″ 11⁄16″ 5⁄16″ 24 AIR INLET 3″ 11⁄16″ E 11⁄16″ 1″ 231⁄4″ SIDE RETURN DUCT LOCATION 5⁄8″ TYP NOTES: 1. Two additional 7⁄8-in. dia holes are located in the top plate. 2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters. 3. Minimum return-air opening at furnace: a. For 800 CFM–16-in. round or 141⁄2 x 12-in. rectangle. b. For 1200 CFM–20-in. round or 141⁄2 x 191⁄2-in. rectangle. c. For 1600 CFM–22-in. round or 141⁄2 x 231⁄4-in. rectangle. d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. A98520 DIMENSIONS (In.) A 14-3/16 14-3/16 14-3/16 14-3/16 17-1/2 21 17-1/2 21 24-1/2 21 24-1/2 24-1/2 D 12-9/16 12-9/16 12-9/16 12-9/16 15-7/8 19-3/8 15-7/8 19-3/8 22-7/8 19-3/8 22-7/8 22-7/8 E 11-11/16 11-11/16 11-11/16 11-11/16 16 18-1/2 16 18-1/2 22 18-1/2 22 22 VENT CONN* (Dia) 4 4 4 4 4 4 4 4 4 5† 5† 5† SHIPPING WEIGHT (Lb) 122 124 132 134 150 154 160 166 184 178 194 204 25 5/8" 23 5/8" 24 3/8" Opening with Flanges Bent 23 3/8" 23 1/8" Opening B Opening UNIT SIZE 024045 036045 024070 036070 042091 048091 036111 048111 060111 048135 060135 060155 MEDIA FILTER CABINET A Furnace Side Duct Side 23 3/4" Centerline Screw Slots 5 3/4" Media/ Filter Cabinet A B 16" 17 16" 20" 21 20" 24" 25 24" * Refer to the furnace Installation Instructions for proper venting procedures. † Oval collar A00309 ama MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. —2— CERTIFIED REGISTERED QUALITY SYSTEM MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION TOP / PLENUM his forced air furnace is equipped for use with This furnace is approved for UPFLOW installations only. natural gas at altitudes 0 - 10,000 ft (0-3,050m). n accessory kit, supplied by the manufacturer, 1" s all be used to convert to propane gas use or m y be required for some natural gas applications. his furnace is for indoor installation in uilding constructed on site. 1" 0" BA # his furnace may be installed on combustible E CK D SI E flooring in alcove or closet at minimum clearance C A RN fr m combustible material. FU T ON his furnace may be used with a Type B-1 Vent FR SE a nd may be vented in common with other gas-fired RV IC a pliances. E E SI # FR 1" # T 30" ## 0" Clearance in inches. ON MIN BOTTOM DESSOUS # For furnaces wider than 14.25 inches (362mm) may be 0 inches. For single wall vent type 6 inches. For Type B-1 vent type 3 inches. D 320325-101 REV. H Vent Clearance to combustibles: For Single Wall vents 6 inches (6 po). For Type B-1 vent type 1 inch (1 po). A98122E CONTROLS—THERMOSTATS AND ZONING THERMOSTAT—NON-PROGRAMMABLE Auto Changeover, °F/°C, 1-Stage Heat/1-Stage Cool — TSTATBBNAC01-B Auto Changeover, °F/°C, 2-Stage Heat/1-Stage Cool — TSTATBBNHP01-B Auto Changeover, °F/°C, 2-Stage Heat/2-Stage Cool — TSTATBBN2S01-B in AC Mode, 3-Stage Heat in AC Mode/2-Stage Cool in HP Mode Air Conditioner, 1-Stage Heat/1-Stage Cool, Manual Changeover, °F/°C — TSTATBBBAC01 Heat Pump, 2-Stage Heat/1-Stage Cool, Manual Changeover, °F/°C — TSTATBBBHP01* THERMOSTAT—PROGRAMMABLE Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool — TSTATBBPAC01-B Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool — TSTATBBPHP01-B Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/2-Stage Cool — TSTATBBP2S01-B in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode Dual Fuel Thermostat, Includes Outdoor Air Temperature Sensor — TSTATBBPDF01-B* Thermidistat Control — Non-Programmable/Programmable Thermostat — TSTATBBPRH01-B* with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) ZONING—2-ZONE ZONEBB2KIT01, ZONEKIT2ZBDP ZONING—4-ZONE ZONEBB4KIT01 ZONING—8-ZONE ZONEBB8KIT01 * Do not use in zoning heat pump applications. —3— SPECIFICATIONS UNIT SIZE RATINGS AND PERFORMANCE Input Btuh* Output Capacity (Btuh)† Nonweatherized ICS AFUE† Nonweatherized ICS Certified Temperature Rise Range °F Certified External Static Pressure Heat/Cool Airflow CFM‡ Heating Cooling ELECTRICAL Unit Volts—Hertz—Phase Operating Voltage Range Min—Max Maximum Unit Amps Maximum Wire Length (Measured 1 Way in Ft) Minimum Wire Size Maximum Fuse or Ckt Bkr Size (Amps)** Transformer (24v) External Control Heating Power Available Cooling Air Conditioning Blower Relay CONTROLS Limit Control Heating Blower Control Burners (Monoport) Gas Connection Size GAS CONTROLS Gas Valve (Redundant) Min Inlet Pressure (In. wc) Max Inlet Pressure (In. wc) Ignition Device BLOWER DATA Direct-Drive Motor HP (PSC) Motor Full Load Amps RPM (Nominal)—Speeds Blower Wheel Diameter x Width (In.) Filter Size (In.)—Permanent Washable (Supplied) 024045 036045 024070 036070 042091 048091 44,000 35,000 80.0 25—55 0.10/0.50 855 880 44,000 35,000 80.0 15—45 0.10/0.50 980 1250 66,000 53,000 80.0 40—70 0.12/0.50 830 880 66,000 53,000 80.0 30—60 0.12/0.50 1140 1195 88,000 71,000 80.0 40—70 0.15/0.50 1170 1360 88,000 71,000 80.0 30—60 0.15/0.50 1445 1740 9.0 31 10.4 27 4 4 1/3 5.8 1075—4 10 x 7 1/2 7.9 1075—4 10 x 8 (1) 20 x 25 x 1 115—60—1 104—127 6.0 47 8.3 34 5.9 47 8.7 32 14 15 40va 12va 35va Standard 2 2 SPST Solid-State Time Operation 3 3 1/2-in. NPT White Rodgers 4.5 (Natural Gas) 13.6 (Natural Gas) Hot Surface 1/5 2.9 1075—3 10 x 6 1/3 5.8 1075—4 10 x 6 FACTORY-AUTHORIZED DEALER-INSTALLED ACCESSORIES Twinning Kit Gas Conversion Kit—Natural-to-Propane Gas Conversion Kit—Propane-to-Natural Air Cleaner Humidifier Ventilator 1/5 2.9 1075—3 10 x 6 (1) 16 x 25 x 1 1/3 5.8 1075—4 10 x 6 N/A KGANP2001ALL KGAPN1601ALL Model AIRA or 902B Model HUM Model VA3B, VB5B, VC5B, or VL3A KGATW0401HSI * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to National Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level. † Capacity and AFUE in accordance with U.S. government DOE test procedures. ‡ • Airflow shown is for bottom only return-air supply with factory-supplied 1-in. washable filter(s). • For air delivery above 1800 CFM, see Air Delivery table for other options. • An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter. • For best furnace efficiency when using the 4-5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range. ** Time-delay type is recommended. ICS—Isolated Combustion System N/A—Not Applicable —4— SPECIFICATIONS UNIT SIZE 036111 RATINGS AND PERFORMANCE Input Btuh* 110,000 Capacity (Btuh)† Nonweatherized ICS 89,000 AFUE† Nonweatherized ICS 80.0 Certified Temperature Rise Range °F 55—85 Certified External Static Pressure Heat/Cool 0.20/0.50 Airflow CFM‡ Heating 1175 Cooling 1205 ELECTRICAL Unit Volts—Hertz—Phase Operating Voltage Range Min—Max Maximum Unit Amps 8.0 Maximum Wire Length (Measured 1 Way in Ft) 35 Minimum Wire Size 14 Maximum Fuse or Ckt Bkr Size (Amps)** 15 Transformer (24v) External Control Heating Power Available Cooling Air Conditioning Blower Relay CONTROLS Limit Control Heating Blower Control Burners (Monoport) 5 Gas Connection Size GAS CONTROLS Gas Valve (Redundant) Min Inlet Pressure (In. wc) Max Inlet Pressure (In. wc) Ignition Device BLOWER DATA Direct-Drive Motor HP (PSC) 1/3 Motor Full Load Amps 5.8 RPM (Nominal)—Speeds 1075—4 Blower Wheel Diameter x Width (In.) 10 x 7 Filter Size (In.)—Permanent Washable (1) 16 x 25 x 1 FACTORY-AUTHORIZED DEALER-INSTALLED ACCESSORIES Twinning Kit N/A Gas Conversion Kit—(Natural-to-Propane) Gas Conversion Kit—(Propane-to-Natural) Air Cleaner Humidifier Ventilator 048111 060111 048135 060135 060155 110,000 89,000 80.0 45—75 0.20/0.50 1415 1575 110,000 89,000 80.0 25—55 0.20/0.50 1750 2225 132,000 107,000 80.0 50—80 0.20/0.50 1645 1620 132,000 107,000 80.0 40—70 0.20/0.50 1775 2025 154,000 124,000 80.0 50—80 0.20/0.50 1770 2055 13.3 33 12 20 14.0 31 12 20 6 7 115—60—1 104—127 10.1 28 14 15 14.4 31 12 20 10.1 28 14 15 40va 12va 35va Standard 5 SPST Solid-State Time Operation 5 6 1/2-in. NPT White Rodgers 4.5 (Natural Gas) 13.6 (Natural Gas) Hot Surface 1/2 7.9 1075—4 10 x 8 (1) 20 x 25 x 1 3/4 11.1 1075—4 11 x 10 (1) 24 x 25 x 1 1/2 7.9 1075—4 10 x 8 (1) 20 x 25 x 1 3/4 3/4 11.1 11.1 1075—4 1075—4 11 x 10 11 x 10 (1) 24 x 25 x 1 KGATW0401HSI KGANP2001ALL KGAPN1601ALL Model AIRA or 902B Model HUM Model VA3B, VB5B, VC5B, or VL3A * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to National Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level. † Capacity and AFUE in accordance with U.S. government DOE test procedures. ‡ • Airflow shown is for bottom only return-air supply with factory-supplied 1-in. washable filter(s). • For air delivery above 1800 CFM, see Air Delivery table for other options. • An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter. • For best furnace efficiency when using the 4-5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range. ** Time-delay type is recommended. ICS—Isolated Combustion System N/A—Not Applicable —5— AIR DELIVERY—CFM (With Filters)* UNIT SIZE RETURN-AIR SUPPLY 024045 Bottom or 1 Side 036045 Bottom or 1 Side 024070 Bottom or 1 Side 036070 Bottom or 1 Side 042091 Bottom or 1 Side 048091 Bottom or 1 Side 036111 Bottom or 1 Side 048111 Bottom or 1 Side Bottom Only 060111 Both Sides or 1 Side & Bottom 1 Side Only 048135 Bottom or 1 Side Bottom Only 060135 Both Sides or 1 Side & Bottom 1 Side Only Bottom Only 060155 Both Sides or 1 Side & Bottom 1 Side Only EXTERNAL STATIC PRESSURE (IN. WC) SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 High Med-High Med-Low High Med-High Med-Low Low High Med-High Med-Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High High Med-High High Med-High Med-Low Low High Med-High Med-Low Low High Med-High High Med-High High Med-High Med-Low Low High Med-High High Med-High 1030 855 755 1490 1335 1140 980 1040 855 745 1430 1310 1140 990 1570 1370 1170 1010 2010 1675 1445 1260 1470 1340 1185 1015 1880 1660 1455 1265 — 2125 1745 1545 2475 2100 2415 2080 1900 1695 1460 1275 — 2110 1790 1495 2425 2055 2245 2050 — — 1790 1520 2405 2090 2325 2085 1005 830 725 1430 1305 1130 975 1010 830 715 1380 1275 1130 965 1535 1355 1165 1005 1950 1660 1430 1260 1415 1305 1175 1010 1815 1615 1410 1265 2465 2120 1750 1545 2465 2080 2340 2050 1845 1645 1415 1260 2260 2070 1775 1500 2360 2035 2175 1985 2300 2050 1770 1525 2385 2090 2260 2045 970 800 695 1385 1270 1105 965 975 800 690 1325 1235 1100 960 1480 1330 1150 990 1875 1625 1415 1260 1340 1245 1140 980 1745 1570 1375 1240 2385 2075 1740 1545 2425 2075 2250 2010 1780 1580 1375 1245 2185 2015 1755 1515 2275 1995 2070 1925 2235 2005 1740 1505 2310 2040 2175 1985 925 765 650 1325 1230 1075 915 935 765 650 1265 1190 1065 935 1415 1290 1115 965 1810 1600 1400 1250 1270 1185 1075 955 1690 1505 1350 1210 2305 2040 1720 1520 2365 2055 2170 1955 1705 1520 1340 1230 2085 1960 1720 1485 2195 1945 1980 1850 2155 1945 1710 1485 2220 1990 2085 1920 880 720 605 1250 1160 1030 875 880 715 605 1195 1135 1000 905 1360 1240 1085 950 1740 1545 1370 1210 1205 1130 1030 910 1575 1435 1290 1180 2225 1985 1685 1495 2305 2015 2070 1885 1620 1460 1290 1180 2025 1885 1670 1450 2095 1880 1900 1765 2055 1880 1635 1450 2140 1925 2000 1855 815 670 555 1175 1090 975 840 810 660 550 1125 1065 965 855 1280 1170 1035 905 1660 1490 1325 1180 1115 1045 950 840 1500 1355 1235 1110 2125 1900 1635 1450 2230 1940 2000 1805 1530 1385 1205 1135 1935 1810 1610 1400 2010 1810 1805 1690 1980 1805 1580 1410 2045 1850 1900 1765 745 595 475 1085 1005 900 785 735 600 475 1045 990 910 800 1185 1080 970 845 1550 1395 1265 1115 985 915 835 725 1400 1260 1145 995 2020 1825 1565 1390 2145 1865 1890 1745 1445 1280 1110 — 1835 1715 1535 1345 1890 1735 1695 1585 1870 1720 1520 1350 1945 1765 1805 1680 615 485 400 975 915 830 715 640 490 385 945 900 815 710 1070 955 880 745 1455 1295 1170 1030 845 780 705 600 1265 1170 985 855 1910 1715 1500 1330 2015 1765 1780 1645 1320 1155 — — 1730 1620 1455 1270 1775 1640 1575 1480 1775 1640 1440 1290 1825 1660 1705 1570 * A filter is required for each return-air supply. Airflow shown is with factory supplied 1-in. washable filter(s). An airflow reduction of up to 7% may occur when using the factory specified 4-5/16-inch wide, high-efficiency media filter. For best furnace efficiency when using the 4-5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range. — Indicates unstable operating conditions. —6— —7— SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS 395CAV.40.7 © 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls., IN 46231 —8— PRINTED IN U.S.A. Catalog No. 5239-502 10-00
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : 3.1-701 Create Date : 2000:11:06 10:24:32Z Modify Date : 2005:11:14 11:46:08-05:00 Metadata Date : 2005:11:14 11:46:08-05:00 Producer : Acrobat Distiller 4.0 for Windows Keywords : Format : application/pdf Title : Description : Creator : Carrier Corporation Subject : Document ID : uuid:ff4099e2-0985-4537-b9f1-53fc9cdff5b5 Instance ID : uuid:34e2f474-d06d-4c82-8891-e3cb4bc45fd3 Page Count : 8 Author : Carrier CorporationEXIF Metadata provided by EXIF.tools