Bryant 561C Users Manual
561C to the manual fd80be34-f468-4cef-a647-f08db2e6ce13
2015-02-02
: Bryant Bryant-561C-Users-Manual-411854 bryant-561c-users-manual-411854 bryant pdf
Open the PDF directly: View PDF .
Page Count: 28
Form No. PDS 561C.18.6
ELECTRIC
AIR CONDITIONER
561C (60 Hz)
Sizes 018 thru 060
Model 561C Energy-Efficient Air Conditioners incorporate inno-
vative technology to provide reliable summer cooling perfor-
mance. Built into these units are the features most desired by
homeowners today including SEER ratings of up to 11.5 when
used with components designated by manufacturer. All models
are listed with UL, c-UL, ARI, CEC, and CSA-EEV.
AVAILABLE OPTIONS
UNIT DESIGN
—Copper tube, enhanced sine wave aluminum
fin coil is designed for optimum heat transfer. Vertical air dis-
charge carries sound and hot condenser air up and away from
adjacent patio areas and foliage. Heat pump-style base pan for
easy removal of water, dirt, and leaves.
ELECTRICAL RANGE
—All units are offered in 208–230v sin-
gle phase. Three-phase units are available from 030 through
060 sizes in 208/230v and from 036 through 060 sizes in 460v.
WIDE RANGE OF SIZES
—The 561C is available in 7 nominal
sizes from 018 through 060 to meet the needs of residential and
light commercial applications.
WEATHER-PROTECTIVE CABINET
—The steel panels are
protected with a galvanized coating then covered with a layer of
zinc phosphate. A modified polyester powder coating is then
applied and baked on, providing each unit with a hard, smooth
finish that will last for many years.
All screws on cabinet exterior are coated for a long-lasting, rust-
resistant, quality appearance.
TOTALLY ENCLOSED FAN MOTOR
—Means greater reliability
under rain conditions and dependable performance for many
years. The permanent-split-capacitor-type motor was designed
for optimum efficiency. Then, under extreme conditions, the
motor was tested and qualified to help ensure the greatest reli-
ability.
APPLICATION VERSATILITY
—The unit can be combined with
a wide variety of evaporator coils and blower packages to pro-
vide quiet, dependable comfort. Unit can be installed on a roof
or at ground level on a slab.
EXTERNAL SERVICE VALVES
—The service valves are brass,
front seating type. The 561C has sweat field connections.
Valves are externally located so refrigerant tube connections
can be made quickly and easily. Each valve has a service port
for ease of checking operating refrigerant pressures.
EASY SERVICEABILITY
—One access panel provides access
to electrical controls and compressor. Removal of wire dome
gives access to fan motor and removal of the top gives access
to the coil.
COMPRESSOR PROTECTION
—Each compressor is pro-
tected with internal temperature- and current-sensitive over-
loads. An internal pressure relief valve provides high-pressure
protection to the refrigerant system.
LIMITED WARRANTY
—Standard 1-year warranty on parts,
with an additional 4-year warranty on compressor.
—2—
DIMENSIONS—561C
A97017
AIR IN
NOTES:
1. Allow 30 in. clearance to service side of
unit, 48 in. above unit, 6 in. on one side, 12 in.
on remaining side, and 24 in. between units for proper airflow.
2. Minimum outdoor operating ambient in cooling mode is
55°F, max. 125°F.
3. Series designation is the 14th position of the unit
model number.
4. Center of gravity .
AIR IN
3/8-IN. DIA
TIEDOWN
KNOCKOUTS
(2) PLACES
H
G
F
E
L
K
J
AIR IN
M
N
AIR DISCHARGE
AIR IN
AIR DISCHARGE AIR DISCHARGE
A SQ
B
P
C
2 7/8″
1 1/4″
FIELD CONTROL SUPPLY
CONN 7/8-IN. DIA HOLE
FIELD POWER SUPPLY CONN
7/8-IN. DIA HOLE WITH
1 1/8-IN. DIA KNOCKOUT
AND 1 3/8-IN. DIA KNOCKOUT
3/8-IN. DIA LIQUID
LINE CONN
D DIA VAPOR LINE CONN
DIMENSIONS (IN.)
UNIT
SIZE SERIES
UNIT DIMENSIONS MINIMUM
MOUNTING
PAD DIMENSIONSABCDEFGHJKLMNP
018 A, D 18 21-15/16 3-3/16 5/8 3 15 16-5/16 17-3/4 10-3/16 16-1/8 17-3/4 7-7/8 8-3/8 9-3/8 18 X 18
024 A, D 18 23-15/16 3-3/16 5/8 3 15 16-5/16 17-3/4 10-3/16 16-1/8 17-3/4 7-7/8 8-3/8 9-1/2 18 X 18
030 A, D 22-1/2 21-15/16 3-3/16 3/4 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-3/8 10-1/4 10-3/4 22-1/2 X 22-1/2
036 A, B, D 22-1/2 25-15/16 3-3/16 3/4 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/4 9-1/2 11-1/4 22-1/2 X 22-1/2
036 E 22-1/2 25-15/16 3-3/16 3/4 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-3/8 10-3/4 11-1/4 22-1/2 X 22-1/2
042 A, C 22-1/2 29-15/16 3-1/4 7/8 3-11/16 18-1/8 19-13/16 22-1/4 14-3/8 19-9/16 22-1/16 10-1/4 9-1/2 11-5/8 22-1/2 X 22-1/2
042 B 22-1/2 29-15/16 3-1/4 7/8 3-11/16 18-1/8 19-13/16 22-1/4 14-3/8 19-9/16 22-1/16 10-3/8 10-3/4 11-1/8 22-1/2 X 22-1/2
048 A, B, C 30 27-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15 13 14-1/2 30 X 30
060 A, E 30 35-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14 15-1/2 30 X 30
060 B 30 29-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14 15 30 X 30
—3—
CHECK-FLO-RATER® PISTON CHART
* Piston listed is for any approved coil non-capillary tube combination.
Piston is shipped with outdoor unit and must be installed in an approved
indoor coil.
RECOMMENDED TUBE DIAMETERS
* For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.
SOUND POWER (dBA)
UNIT SIZE PISTON*
IDENTIFICATION NO.
018-A, D 52
024-A, D 57
030-A, D 67
036-A, D, E 73
036-B 70
042-A, C 76
042-B 82
048-A, C 88
048-B 84
060-A, E 93
060-B 90
UNIT
SIZE
Liquid Tube Diameter (In.) Vapor Tube Diameter (In.)
0 to 50 Ft
Tube Length Long-Line Applications* 0 to 50 Ft
Tube Length Long-Line Applications*
(Maximum Diameter)
018, 024
3/8 3/8
5/8 3/4
030, 036 3/4 7/8
042, 048 7/8 1-1/8
060 1-1/8 1-1/8
UNIT
SIZE SOUND
LEVEL (dBA)
OCTAVE BAND CENTER FREQUENCY (Hz)
125 250 500 1000 2000 4000 8000
018-A 80 55.5 64.0 68.5 73.0 71.0 66.5 59.5
018-D 80 57.5 64.0 69.5 72.0 71.5 68.0 60.0
024-A 80 59.5 65.0 69.5 74.0 73.0 70.0 62.0
024-D 82 55.5 63.0 68.0 71.0 70.5 67.5 58.5
030-A 80 55.0 62.5 73.5 74.0 71.0 67.5 59.5
030-D 80 54.0 68.5 72.5 73.0 70.5 67.0 61.5
036-A 82 57.0 64.5 73.0 74.0 72.0 73.0 65.5
036-B 82 55.0 64.0 73.0 74.5 72.0 68.5 64.0
036-D 82 56.0 64.5 69.0 75.5 75.0 72.0 69.5
036-E 82 56.5 70.0 73.5 75.5 74.5 71.0 65.0
042-A 82 58.0 69.5 73.0 71.5 69.5 68.0 63.5
042-B 82 59.0 66.5 68.5 75.5 71.5 73.0 65.5
042-C 82 57.0 69.0 72.5 71.5 69.5 68.0 64.0
048-A 82 58.5 72.5 74.0 77.0 72.5 70.0 65.0
048-B 82 57.0 67.5 72.0 73.0 68.5 67.0 60.5
048-C 82 61.0 69.0 70.0 74.0 75.5 74.5 66.5
060-A 82 57.5 68.0 69.0 72.5 70.5 71.0 70.0
060-B 82 57.5 69.5 75.0 76.0 70.5 69.0 63.0
060-E 82 58.0 64.0 70.0 74.0 72.0 71.0 67.0
M
A
N
U
F
A
C
T
U
R
E
R
C
E
R
T
I
F
I
E
D
T
O
A
R
I
A
S
C
O
M
P
L
Y
I
N
G
W
I
T
H
A
R
I
S
T
A
N
D
A
R
D
2
1
0
U
N
I
T
A
R
Y
A
I
R
C
O
N
D
I
T
I
O
N
I
N
G
E
Q
U
I
P
M
E
N
T
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.
REGISTERED QUALITY SYSTEM
—4—
SPECIFICATIONS
See notes on page 7.
UNIT SIZE-SERIES 561C018-A, D 561C024-A, D 561C030-A, D 561C030-A
Operating Weight (Lb) 113/115 115/117 124/133 124
ELECTRICAL
Unit Volts—Hertz—Phase 208-230—60—1 208/230—60—3
Operating Voltage Range* 197—253 187—253
Compressor— Rated Load Amps 9.6/9.0 10.7/11.6 14.2/14.8 9.4
Locked Rotor Amps 49.0/48.0 56.0/60.0 75.0/73.0 68.0
Condenser Fan Motor—Full Load Amps 0.8 1.0 0.8 0.8
Min Unit Ampacity for Wire Sizing 12.8/12.1 14.4/15.5 18.6/19.3 12.6
Min Wire Size (60°C Copper) AWG† 14
Min Wire Size (75°C Copper) AWG† 14
Max Wire Length (60°C) (Ft)‡ 61/65 50/49 40 70
Max Wire Length (75°C) (Ft)‡ 58/61 50/47 40/38 65
Max Branch Circuit Fuse Size** 20/15 20 25 15
COMPRESSOR & REFRIGERANT
Compressor— Manufacturer Copeland/Bristol Copeland
Type Reciprocating
Temperature and Current Protection Internal Line Break
Refrigerant—Type and Amount @ 15 Ft R-22 and 3.25/3.30 R-22 and 3.76/3.65 R-22 and 4.19/4.25 R-22 and 4.19
CONDENSER COIL & FAN
Coil Face Area (Sq Ft) 5.6 6.2 7.4
Fins Per In.—Rows—Circuit 25—1—1/
22—1—1 25—1—1/
22—1—1 25—1—1/
25—1—1 25—1—2
Fan Motor—PSC Type, HP and RPM 1/8 and 1500 1/6 and 1500 1/10 and 1125 1/10 and 1125
Volts—Hertz—Phase 208/230—60—1
Condenser Airflow (CFM) 1400/1500 1550/1600 2000 1700
OPTIONAL EQUIPMENT
Coastal Filter KAACF0601SML KAACF0401MED
Time-Delay Relay KAATD0101TDR
Cycle Protector KSACY0101AAA
Low-Ambient Controller N/A P251-0083 (RCD)
Crankcase Heater KAACH1001AAA
Inlet Grille Kit KSABG0105CMC KSABG0205CMC KSABG0604CSM
Start Assist—Capacitor/Relay Type†† KSAHS0901AAA KSAHS1001AAA/KSAHS0901AAA/KSAHS0901AAA N/A
Start Assist—PTC Type KAACS0201PTC N/A
Sound Hood N/A N/A / KSASH1301TEC/
KSASH2001BRL N/A / KSASH1301TEC
TXV (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB
TXV (Hard Shutoff)†† KSATX0601HSO
Low-Pressure Switch KAALP0101LPS
High-Pressure Switch KSAHI0101HPS
Filter Drier P502-8083S (RCD)
Evaporator Freeze Thermostat‡‡ KAAFT0101AAA
Liquid-Line Solenoid Valve†† KAALS0101LLS
Winter Start Control‡‡ KAAWS0101AAA
MotorMaster® Control*** N/A 32LT660004 (RCD)
Ball Bearing Fan Motor N/A HC34GE231 (RCD)
Thermostat, Auto Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Builder’s Thermostat, Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B
Thermidistat Control, Programmable/
Non-Programmable Thermostat with
Humidity Control TSTATBBPRH01-B
Outdoor Air Temperature Sensor TSTATXXSEN01-B
Backplate for Non-Programmable
Thermostat TSTATXXNBP01
Backplate for Programmable Thermostat TSTATXXPBP01
Backplate for Builder’s Thermostat TSTATXXBBP01
Thermostat Conversion Kit (4 to 5 wire) TSTATXXCNV10
—5—
SPECIFICATIONS Continued
See notes on page 7.
UNIT SIZE-SERIES
561C036-A, B, E 561C036-B, D 561C036-B 561C042-A, B 561C042-B, C 561C042-B
Operating Weight (Lb) 129/138/138 129/133 133 138/142 142
ELECTRICAL
Unit Volts—Hertz—Phase 208-230—60—1 208/230—60—3 460—60—3 208-230—60—1 208/230—60—3 460—60—3
Operating Voltage Range* 197—253 187—253 414—506 197—253 187—253 414—506
Compressor— Rated Load Amps
16.7/14.8/16.0
10.0/10.6 5.1 20.5/19.7 13.6/12.4 6.2
Locked Rotor Amps
95.0/86.0/81.0
75.0/64.5 33.0 115.0/102.0 91.0/90.0 42.0
Condenser Fan Motor—Full Load Amps 1.4 1.4 0.8 1.4 1.4 0.8
Min Unit Ampacity for Wire Sizing
22.3/19.9/21.4
13.9/14.7 7.2 27.0/26.0 18.4/16.9 8.6
Min Wire Size (60°C Copper) AWG† 12 14 14 10 14 14
Min Wire Size (75°C Copper) AWG† 12 14 14 10 14 14
Max Wire Length (60°C) (Ft)‡ 55/55/58 65/60 250 70/75 45/50 210
Max Wire Length (75°C) (Ft)‡ 50/55/55 62/55 238 70 45/50 200
Max Branch Circuit Fuse Size** 30 20 15 40 25 15
COMPRESSOR & REFRIGERANT
Compressor— Manufacturer Millennium/
Copeland/Bristol Copeland/
Millennium Copeland Millennium/
Copeland Copeland/
Millennium Copeland
Type Scroll/
Reciprocating/
Reciprocating
Reciprocating/
Scroll Reciprocating Scroll/
Reciprocating Reciprocating/
Scroll Reciprocating
Temperature and Current Protection Internal Line Break
Refrigerant—Type and Amount @ 15 Ft R-22 and 4.63/
5.00/4.60 R-22 and 5.00/
4.63 R-22 and 5.00 R-22 and 5.00/
5.13 R-22 and 5.13/
5.00 R-22 and 5.13
CONDENSER COIL & FAN
Coil Face Area (Sq Ft) 9.1 10.7
Fins Per In.—Rows—Circuit 20—1—2/
25—1—2/
25—1—2
25—1—2/
20—1—2 25—1—2 22—1—3/
25—1—3 25—1—3/
22—1—3 25—1—3
Fan Motor—PSC Type, HP and RPM 1/5 and 1125/
1100/1125 1/5 and 1125 1/4 and 1125 1/5 and 1125 1/4 and 1125
Volts—Hertz—Phase 208/230—60—1 460—60—1 208/230—60—1 460—60—1
Condenser Airflow (CFM) 2500 3400
OPTIONAL EQUIPMENT
Coastal Filter KAACF0401MED
Time-Delay Relay KAATD0101TDR
Cycle Protector
Standard/
KSACY0101AAA/
KSACY0101AAA
KSACY0101AAA Standard/
KSACY0101AAA KSACY0101AAA
Low-Ambient Controller P251-0083 (RCD)
Crankcase Heater
KAACH1201AAA /
KAACH1001AAA/
KAACH1001AAA
KAACH1201AAA/
KAACH1001AAA KAACH1101AAA KAACH1201AAA/KAACH1001AAA KAACH1101AAA
Inlet Grille Kit
KSABG0804CSM
KSABG1004CSM
Start Assist—Capacitor/Relay Type††
KSAHS1501AAA/
KSAHS1001AAA/
KSAHS1101AAA
N/A KSAHS1501AAA/
KSAHS1301AAA N/A
Start Assist—PTC Type
KAACS0201PTC
N/A KAACS0201PTC N/A
Sound Hood
KSASH1901CYL/
KSASH1201COP/
KSASH2001BRL
KSASH1901CYL/
N/A N/A
KSASH1901CYL /KSASH1201COP KSASH1201COP
TXV (RPB) KAATX0501RPB
TXV (Hard Shutoff)†† KSATX0601HSO
Low-Pressure Switch KAALP0101LPS
High-Pressure Switch KSAHI0101HPS
Filter Drier P502-8083S (RCD) P502-8163S (RCD)
Evaporator Freeze Thermostat‡‡ KAAFT0101AAA
Liquid-Line Solenoid Valve†† KAALS0101LLS
Winter Start Control‡‡ KAAWS0101AAA
MotorMaster® Control*** 32LT660004 (RCD)
32LT660005 (RCD)
32LT660004 (RCD)
32LT660005 (RCD)
Ball Bearing Fan Motor HC40GE230 (RCD)
HC40GE461 (RCD)
HC40GE230 (RCD)
HC40GE461 (RCD)
Thermostat, Auto Changeover,
Non-Programmable, °F/°C, 1-Stage Heat,
1-Stage Cool TSTATBBNAC01-B
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Builder’s Thermostat, Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B
Outdoor Air Temperature Sensor TSTATXXSEN01-B
Backplate for Non-Programmable Thermostat TSTATXXNBP01
Backplate for Programmable Thermostat TSTATXXPBP01
Backplate for Builder’s Thermostat TSTATXXBBP01
Thermostat Conversion Kit (4 to 5 wire) TSTATXXCNV10
—6—
SPECIFICATIONS Continued
See notes on page 7.
UNIT SIZE-SERIES 561C048-A, B 561C048-B, C 561C060-A, B 561C060-B, E
Operating Weight (Lb) 192/198 233/218
ELECTRICAL
Unit Volts—Hertz—Phase
208-230—60—1 208/230—60—3
460—60—3
208-230—60—1 208/230—60—3
460—60—3
Operating Voltage Range* 197—253 187—253 414—506 197—253 187—253 414—506
Compressor— Rated Load Amps 24.4/23.7 13.5/14.1 7.4/7.1 28.9/28.8 18.3/16.0 9.0/8.0
Locked Rotor Amps 140.0/129.0 120.0/105.0 49.5/52.5 165.0/169.0 137.0/125.0 62.0/66.5
Condenser Fan Motor—Full Load Amps 1.4 1.4 0.8 1.4 1.4 0.8
Min Unit Ampacity for Wire Sizing 31.9/31.0 18.3/19.0 10.1/9.7 37.5/37.4 24.3/21.4 12.1/10.8
Min Wire Size (60°C Copper) AWG† 8 14 14 8 12 14
Min Wire Size (75°C Copper) AWG† 10 14 14 8 12 14
Max Wire Length (60°C) (Ft)‡ 95/100 45/48 185/182 80 58/68 150/165
Max Wire Length (75°C) (Ft)‡ 55/60 45/46 175/173 75 55/65 142/157
Max Branch Circuit Fuse Size** 50 25 15 60 35/30 15
COMPRESSOR & REFRIGERANT
Compressor—Manufacturer Millennium/
Copeland Copeland/
Millennium Millennium/
Copeland Copeland/
Millennium
Type Scroll Scroll Scroll Scroll
Temperature and Current Protection Internal Line Break
Refrigerant—Type and Amount @ 15 Ft R-22 and 6.63/6.38 R-22 and 9.89/8.46
CONDENSER COIL & FAN
Coil Face Area (Sq Ft) 14.8 19.8/16.1
Fins Per In.—Rows—Circuits 22—1—3/17—1—3 25—1—4
Fan Motor—PSC Type, HP and RPM 1/4 and 1125
Volts—Hertz—Phase 208/230—60—1 460—60—1 208/230—60—1 460—60—1
Condenser Airflow (CFM) 3400
OPTIONAL EQUIPMENT
Coastal Filter KAACF0501LRG
Time-Delay Relay KAATD0101TDR
Cycle Protector
Standard/
KSACY0101AAA KSACY0101AAA Standard/
KSACY0101AAA KSACY0101AAA
Low-Ambient Controller P251-0083 (RCD)
Crankcase Heater KAACH1201AAA KAACH1301AAA KAACH1201AAA KAACH1301AAA
Inlet Grille Kit K5ABG1704CMD KSABG1804CMD KSABG2104CMD
Start Assist—Capacitor/Relay Type†† KSAHS1601AAA N/A KSAHS1601AAA N/A
Start Assist—PTC Type KAACS0201PTC N/A KAACS0201PTC N/A
Sound Hood KSASH2001CYL
/
KSASH2101COP
TXV Kit (RPB) KAATX0601RPB KAATX0701RPB
TXV (Hard Shutoff)†† KSATX0701HSO
Low-Pressure Switch KAALP0101LPS
High-Pressure Switch KSAHI0101HPS
Filter Drier P502-8163S (RCD)
Evaporator Freeze Thermostat‡‡ KAAFT0101AAA
Liquid-Line Solenoid Valve†† KAALS0101LLS
Winter Start Control‡‡ KAAWS0101AAA
MotorMaster® Control*** 32LT660004 (RCD)
32LT660005 (RCD)
32LT660004 (RCD)
32LT660005 (RCD)
Ball Bearing Fan Motor HC40GE230 (RCD)
HC40GE461 (RCD)
HC40GE230 (RCD)
HC40GE461 (RCD)
Thermostat, Auto Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Builder’s Thermostat, Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B
Outdoor Air Temperature Sensor TSTATXXSEN01-B
Backplate for Non-Programmable Thermostat TSTATXXNBP01
Backplate for Programmable Thermostat TSTATXXPBP01
Backplate for Builder’s Thermostat TSTATXXBBP01
Thermostat Conversion Kit (4 to 5 wire) TSTATXXCNV10
—7—
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26.
If other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than
10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
‡ Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time-delay fuse or circuit breaker.
†† Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 036 and 042, Series A; 048 and 060, Series A/B
single phase; and all 3-phase units). Do not use hard shutoff TXV with liquid solenoid valve.
‡‡ Use with low-ambient controller.
*** Fan motor with ball bearings required.
N/A—Not Applicable
NOTES:
1. All motors/compressors contain internal overload protection.
2. Copper wire must be used from service disconnect to unit.
3. Control circuit is 24v on all units and requires external power source.
ACCESSORY USAGE GUIDELINE
* For tubing line sets between 50 and 175 ft, refer to Residential’s Split Systems Long-Line Application Guidelines.
† Only when low-pressure switch is used.
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
1. Ball Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added.
2. Coastal Filter
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.
SUGGESTED USE: In geographic areas where salt damage could occur.
3. Compressor Start Assist—Capacitor/Relay Type
Start capacitor and start relay which gives ‘‘hard’’ boost to compressor motor at each start-up.
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.
Installations where outdoor design temperature exceeds 105°F (40.6°C).
Replacement installations with hard shutoff expansion valve on indoor coil.
Installations where Liquid-Line Solenoid Valve has been added.
4. Compressor Start Assist—PTC Type
Solid-state electrical device which gives a ‘‘soft’’ boost to compressor motor at each start-up.
SUGGESTED USE: Installations with marginal power supply.
Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil.
5. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication
on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. (Use with Low-Ambient Controller.)
All commercial installations.
6. Cycle Protector
Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has
been interrupted for any reason, including normal room thermostat cycling.
SUGGESTED USE: Installations in areas where power interruptions are frequent.
Where user is likely to ‘‘play’’ with the room thermostat.
All commercial installations.
Installations where interconnecting tube length exceeds 50 ft.
High-rise applications.
7. Evaporator Freeze Thermostat
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.
SUGGESTED USE: All units where Winter Start Control has been added.
8. Filter Drier
A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow.
SUGGESTED USE: All split-system units.
ACCESSORY
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Winter Start Control Yes† No No
Accumulator No No No
Compressor Start Assist
Capacitor and Relay Yes Yes No
Low Ambient Controller
or
MotorMaster® Control Yes N o No
Wind Baffle See Low-Ambient Instructions No No
Coastal Filter No No Yes
Support Feet Recommended No Recommended
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV No See Long-Line
Application
Guideline No
Ball Bearing Fan Motor Yes No No
—8—
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued
9. High-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10
psig and resets at 298 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling,
Cycle Protector can be used with this switch.
SUGGESTED USE: Installations exposed to very ‘‘dirty’’ outdoor air.
Installations where condenser inlet air temperature exceeds 125°F (51.7°C).
10. Inlet Grille Kit
A field-installed enhanced inlet grille to replace the standard inlet grille on residential air conditioners and heat pumps.
SUGGESTED USE: For greater protection against inclement weather, incidental damage, and vandalism.
11. Liquid-Line Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts
refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.
Note:
Compressor Start Assist–Capacitor/Relay Type must also be used. Do not use with hard shutoff TXV.
SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
In certain long-line-applications. Refer to Long-Line Application Guideline.
12. Low-Ambient Controller
Head-pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. It is designed to cycle
the outdoor fan motor in order to maintain condensing temperature within normal operating limits (approximately 100°F high and 60°F low).
The control will maintain working head pressure at low-ambient temperatures down to 0°F when properly installed.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).
13. Low-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27
psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Provides protection against compressor damage due to loss of refrigerant charge. To
prevent rapid compressor recycling, Cycle Protector can be used with this switch.
SUGGESTED USE: Where indoor coil is exposed to ‘‘dirty’’ air.
All commercial installations.
14. MotorMaster® Control
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing
temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ± 10°F.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F.
All commercial installations.
15. Outdoor Air Temperature Sensor
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat
SUGGESTED USE: All corporate programmable thermostats.
16. Sound Hood
Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2 dBA.
SUGGESTED USE: Unit installed closer than 15 ft to quiet areas—bedrooms, etc.
Unit installed between 2 houses less than 10 ft apart.
17. Thermostatic Expansion Valve (TXV)
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the
evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB valves are available. Do not use hard shutoff TXV
with Liquid-Line Solenoid Valve.
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
Required for use on all zoning systems.
18. Time-Delay Relay
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
Required for use on all zoning systems.
19. Winter Start Control
An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load
conditions.
SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added.
—9—
COMBINATION RATINGS
See notes on page 14.
UNIT
SIZE-SERIES INDOOR
MODEL TOT. CAP.
BTUH
FACTORY-
SUPPLIED
ENHANCE-
MENT STANDARD
RATING
BRYANT GAS
FURNACE OR
ACCESSORY
TDR†
ACCESSORY
TXV‡ EERA
018-A, D
CC5A/CD5AA018* 17,200 NONE — 10.00 10.00 9.20
CC5A/CD5AA024 17,600 NONE 10.00 10.50 10.50 9.45
CC5A/CD5AW024 17,600 NONE 10.00 10.50 10.50 9.45
CE3AA024 17,800 NONE 10.00 10.50 10.50 9.50
CF5AA024 17,800 NONE 10.00 10.50 10.50 9.50
CK3BA024 17,600 NONE 10.00 10.50 10.50 9.55
CK5A/CK5BA018 17,200 NONE — 10.00 10.00 9.35
CK5A/CK5BA024 17,600 NONE 10.00 10.50 10.50 9.55
CK5A/CK5BW024 17,600 NONE 10.00 10.50 10.50 9.55
F(A,B)4AN(F,C)018 16,800 TDR 10.00 — 10.00 9.25
F(A,B)4AN(F,C)024 17,600 TDR 10.50 — 10.50 9.60
FC4BNF024 17,600 TDR&TXV 10.50 — — 9.60
FF1(B,C,D)NA018 17,200 TDR 10.50 — 10.50 9.55
FF1(B,C,D)NA024 17,600 TDR 10.50 — 10.50 9.55
FG3AAA024 17,500 NONE — 10.20 10.20 9.35
FK4CNF001 17,500 TDR&TXV 11.50 — — 10.70
FK4CNF002 17,600 TDR&TXV 11.50 — — 10.80
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE
CC5A/CD5AA018 17,200 TDR 11.00 — 11.00 10.10
CC5A/CD5AA024 17,600 TDR 11.20 — 11.20 10.45
CK3BA024 17,600 TDR 11.20 — 11.20 10.60
CK5A/CK5BA018 17,200 TDR 11.00 — 11.00 10.30
CK5A/CK5BA024 17,600 TDR 11.20 — 11.20 10.60
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AW024 17,600 TDR 11.20 — 11.20 10.25
CK3BA024 17,600 TDR 11.20 — 11.20 10.35
CK5A/CK5BW024 17,600 TDR 11.20 — 11.20 10.35
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AW024 17,600 TDR 11.20 — 11.20 10.30
CK5A/CK5BW024 17,600 TDR 11.20 — 11.20 10.45
024-A, D
CC5A/CD5AA024* 22,400 NONE — 10.00 10.00 9.05
CC5A/CD5AA030 22,600 NONE — 10.00 10.00 9.10
CC5A/CD5AW024 22,400 NONE — 10.00 10.00 9.05
CC5A/CD5AW030 22,600 NONE — 10.00 10.00 9.10
CE3AA024 22,600 NONE — 10.00 10.00 9.10
CE3AA030 23,000 NONE — 10.20 10.20 9.20
CF5AA024 22,600 NONE — 10.00 10.00 9.10
CK3BA024 22,400 NONE — 10.00 10.00 9.15
CK3BA030 22,600 NONE — 10.00 10.00 9.15
CK5A/CK5BA024 22,400 NONE — 10.00 10.00 9.15
CK5A/CK5BA030 22,600 NONE — 10.00 10.00 9.15
CK5A/CK5BW024 22,400 NONE — 10.00 10.00 9.15
CK5A/CK5BW030 22,600 NONE — 10.00 10.00 9.15
F(A,B)4AN(F,C)024 22,600 TDR 10.00 — 10.00 9.20
F(A,B)4AN(F,C)030 23,000 TDR 10.20 — 10.20 9.30
FC4BNF024 22,600 TDR & TXV 10.00 — — 9.20
FC4BNF030 23,000 TDR & TXV 10.20 — — 9.30
FF1(B,C,D)NA024 22,600 TDR 10.00 — 10.00 9.05
FF1(B,C,D)NA030 23,200 TDR 10.00 — 10.00 9.20
FG3AAA024 22,000 NONE — 10.00 10.00 8.95
FK4CNF001 23,200 TDR & TXV 11.20 — — 10.15
FK4CNF002 23,400 TDR & TXV 11.30 — — 10.20
FK4CNF003 23,600 TDR & TXV 11.50 — — 10.40
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE
CC5A/CD5AA024 22,400 TDR 10.50 — 10.50 9.80
CC5A/CD5AA030 22,600 TDR 11.00 — 11.00 9.95
CC5A/CD5AW030 22,600 TDR 11.00 — 11.00 9.95
CK5A/CK5BA024 22,400 TDR 10.50 — 10.50 9.90
CK5A/CK5BA030 22,600 TDR 11.00 — 11.00 10.00
CK5A/CK5BW030 22,600 TDR 11.00 — 11.00 10.00
CK3BA024 22,400 TDR 10.50 — 10.50 9.90
CK3BA030 22,600 TDR 11.00 — 11.00 10.00
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CC5A/CD5AW030 22,600 TDR 10.50 — 10.50 9.80
CK5A/CK5BW030 22,600 TDR 10.50 — 10.50 9.85
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AW024 22,400 TDR 10.50 — 10.50 9.70
CC5A/CD5AW030 22,600 TDR 10.50 — 10.50 9.80
CK3BA024 22,400 TDR 10.50 — 10.50 9.75
CK3BA030 22,600 TDR 10.50 — 10.50 9.85
CK5A/CK5BW024 22,400 TDR 10.50 — 10.50 9.75
CK5A/CK5BW030 22,600 TDR 10.50 — 10.50 9.85
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AW024 22,400 TDR 10.50 — 10.50 9.90
CC5A/CD5AW030 22,600 TDR 11.00 — 11.00 10.00
CK5A/CK5BW024 22,400 TDR 10.50 — 10.50 9.95
CK5A/CK5BW030 22,600 TDR 11.00 — 11.00 10.05
—10—
COMBINATION RATINGS Continued
See notes on page 14.
UNIT
SIZE-SERIES INDOOR
MODEL TOT. CAP.
BTUH
FACTORY-
SUPPLIED
ENHANCE-
MENT STANDARD
RATING
BRYANT GAS
FURNACE OR
ACCESSORY
TDR†
ACCESSORY
TXV‡ EERA
030-A, D
CD5A/CD5AA030* 28,000 NONE 10.00 10.10 10.10 9.10
CC5A/CD5AA036 29,000 NONE 10.00 10.10 10.10 9.30
CC5A/CD5AW030 28,000 NONE 10.00 10.10 10.10 9.10
CD5AW036 29,000 NONE 10.00 10.10 10.10 9.30
CE3AA030 27,800 NONE 10.00 10.10 10.10 9.15
CE3AA036 28,600 NONE 10.00 10.10 10.10 9.25
CF5AA036 28,800 NONE 10.00 10.10 10.10 9.30
CK3BA030 28,000 NONE 10.00 10.10 10.10 9.10
CK3BA036 29,000 NONE 10.00 10.10 10.10 9.35
CK5A/CK5BA030 28,000 NONE 10.00 10.10 10.10 9.10
CK5A/CK5BA036 29,000 NONE 10.00 10.10 10.10 9.35
CK5A/CK5BN036 27,000 NONE 10.00 10.10 10.10 9.35
CK5A/CK5BT036 29,000 NONE 10.00 10.10 10.10 9.35
CK5A/CK5BW030 28,000 NONE 10.00 10.10 10.10 9.10
CK5A/CK5BW036 29,000 NONE 10.00 10.10 10.10 9.35
F(A,B)4AN(F,C)030 27,600 TDR 10.00 — 10.00 9.20
F(A,B)4AN(F,C)036 28,200 TDR 10.00 — 10.00 9.10
FC4BNF030 27,600 TDR & TXV 10.00 — — 9.20
FC4BNF036 28,200 TDR & TXV 10.00 — — 9.10
FF1(B,C,D)NA030 28,000 TDR 10.00 — 10.00 9.10
FG3AAA036 28,000 NONE 10.00 10.10 10.10 9.20
FK4CNF001 29,000 TDR & TXV 11.00 — — 9.95
FK4CNF002 29,200 TDR & TXV 11.00 — — 10.00
FK4CNF003 29,400 TDR & TXV 11.50 — — 10.30
FK4CNF005 29,600 TDR & TXV 11.50 — — 10.55
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE
CC5A/CD5AA030 28,000 TDR 10.50 — 10.50 9.70
CC5A/CD5AA036 29,000 TDR 11.00 — 11.00 10.00
CC5A/CD5AW030 28,000 TDR 10.50 — 10.50 9.70
CK3BA030 28,000 TDR 10.50 — 10.50 9.70
CK3BA036 29,000 TDR 11.00 — 11.00 10.05
CK5A/CK5BA030 28,000 TDR 10.50 — 10.50 9.70
CK5A/CK5BA036 29,000 TDR 11.00 — 11.00 10.05
CK5A/CK5BN036 27,000 TDR 11.00 — 11.00 9.90
CK5A/CK5BT036 29,000 TDR 11.00 — 11.00 10.05
CK5A/CK5BW030 28,000 TDR 10.50 — 10.50 9.70
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE
CC5A/CD5AW030 28,000 TDR 10.50 — 10.50 9.80
CD5AW036 29,000 TDR 11.00 — 11.00 10.15
CK5A/CK5BW030 28,000 TDR 10.50 — 10.50 9.85
CK5A/CK5BW036 29,000 TDR 11.00 — 11.00 10.20
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CC5A/CD5AW030 28,000 TDR 10.50 — 10.50 9.50
CD5AW036 29,000 TDR 11.00 — 11.00 9.85
CK5A/CK5BW030 28,000 TDR 10.50 — 10.50 9.50
CK5A/CK5BW036 29,000 TDR 11.00 — 11.00 9.85
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AA036 29,000 TDR 11.00 — 11.00 9.80
CC5A/CD5AW030 28,000 TDR 10.50 — 10.50 9.50
CK3BA030 28,000 TDR 10.50 — 10.50 9.50
CK3BA036 29,000 TDR 11.00 — 11.00 9.85
CK5A/CK5BA036 29,000 TDR 11.00 — 11.00 9.85
CK5A/CK5BT036 29,000 TDR 11.00 — 11.00 9.85
CK5A/CK5BW030 28,000 TDR 10.50 — 10.50 9.50
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AW030 28,000 TDR 10.50 — 10.50 9.55
CD5AW036 29,000 TDR 11.00 — 11.00 9.90
CK5A/CK5BW030 28,000 TDR 10.50 — 10.50 9.60
CK5A/CK5BW036 29,000 TDR 11.00 — 11.00 9.95
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CC5A/CD5AW030 28,000 TDR 10.50 — 10.50 9.45
CD5AW036 29,000 TDR 11.00 — 11.00 9.80
CK5A/CK5BW030 28,000 TDR 10.50 — 10.50 9.50
CK5A/CK5BW036 29,000 TDR 11.00 — 11.00 9.85
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AW030 28,000 TDR 10.50 — 10.50 9.75
CD5AW036 29,000 TDR 11.00 — 11.00 10.10
CK5A/CK5BW030 28,000 TDR 10.50 — 10.50 9.80
CK5A/CK5BW036 29,000 TDR 11.00 — 11.00 10.10
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CD5AW036 29,000 TDR 11.00 — 11.00 10.05
CK5A/CK5BW036 29,000 TDR 11.00 — 11.00 10.05
036-A, B, D, E
CC5A/CD5AA036* 33,800 NONE 10.00 10.20 10.20 9.20
CC5A/CD5AA042 33,800 NONE 10.00 10.20 10.20 9.20
CC5A/CD5AW042 33,800 NONE 10.00 10.20 10.20 9.15
CD5AW036 33,800 NONE 10.00 10.20 10.20 9.20
CE3AA036 33,400 NONE 10.00 10.20 10.20 9.10
CE3AA042 33,600 NONE 10.00 10.20 10.20 9.25
CF5AA036 33,600 NONE 10.00 10.20 10.20 9.15
—11—
COMBINATION RATINGS Continued
See notes on page 14.
UNIT
SIZE-SERIES INDOOR
MODEL TOT. CAP.
BTUH
FACTORY-
SUPPLIED
ENHANCE-
MENT STANDARD
RATING
BRYANT GAS
FURNACE OR
ACCESSORY
TDR†
ACCESSORY
TXV‡ EERA
036-A, B, D, E
CK3BA036 33,800 NONE 10.00 10.20 10.20 9.20
CK3BA042 33,800 NONE 10.00 10.20 10.20 9.20
CK5A/CK5BA036 33,800 NONE 10.00 10.20 10.20 9.20
CK5A/CK5BA042 33,800 NONE 10.00 10.20 10.20 9.20
CK5A/CK5BN036 31,400 NONE 10.00 10.20 10.20 9.30
CK5A/CK5BN042 33,800 NONE 10.00 10.20 10.20 9.20
CK5A/CK5BT036 33,800 NONE 10.00 10.20 10.20 9.20
CK5A/CK5BT042 33,800 NONE 10.00 10.20 10.20 9.20
CK5A/CK5BW036 33,800 NONE 10.00 10.20 10.20 9.20
F(A,B)4AN(F,B,C)042 33,800 TDR 10.00 — 10.00 9.15
F(A,B)4AN(F,C)036 33,000 TDR 10.00 — 10.00 8.90
FC4BN(F,B)042 33,800 TDR & TXV 10.00 — — 9.15
FC4BNB054 34,800 TDR & TXV 10.50 — — 9.70
FC4BNF036 33,000 TDR & TXV 10.00 — — 8.90
FG3AAA036 32,600 NONE — 10.00 10.00 9.05
FK4CNB006 35,200 TDR & TXV 11.00 — — 10.55
FK4CNF001 33,000 TDR & TXV 10.00 — — 9.60
FK4CNF002 33,000 TDR & TXV 10.00 — — 9.60
FK4CNF003 33,600 TDR & TXV 10.50 — — 10.05
FK4CNF005 35,000 TDR & TXV 11.00 — — 10.35
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE
CC5A/CD5AA036 33,400 TDR 10.50 — 10.50 9.65
CK3BA036 33,400 TDR 10.50 — 10.50 9.65
CK5A/CK5BA036 33,400 TDR 10.50 — 10.50 9.65
CK5A/CK5BN036 31,400 TDR 10.50 — 10.50 9.55
CK5A/CK5BT036 33,400 TDR 10.50 — 10.50 9.65
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 33,400 TDR 10.80 — 10.80 9.85
CC5A/CD5AW042 33,400 TDR 10.80 — 10.80 9.80
CD5AW036 33,400 TDR 10.50 — 10.50 9.80
CK3BA042 33,400 TDR 10.80 — 10.80 9.85
CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 9.85
CK5A/CK5BT042 33,400 TDR 10.80 — 10.80 9.85
CK5A/CK5BW036 33,400 TDR 10.50 — 10.50 9.80
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 33,400 TDR 10.80 — 10.80 10.05
CD5AW036 33,400 TDR 10.50 — 10.50 10.00
CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 10.10
CK5A/CK5BT042 33,400 TDR 10.80 — 10.80 10.10
CK5A/CK5BW036 33,400 TDR 10.50 — 10.50 10.05
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 33,400 TDR 10.80 — 10.80 10.00
CD5AW036 33,400 TDR 10.50 — 10.50 9.95
CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 10.00
CK5A/CK5BT042 33,400 TDR 10.80 — 10.80 10.00
CK5A/CK5BW036 33,400 TDR 10.50 — 10.50 9.95
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 33,400 TDR 10.80 — 10.80 9.75
CD5AW036 33,400 TDR 10.50 — 10.50 9.70
CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 9.80
CK5A/CK5BT042 33,400 TDR 10.80 — 10.80 9.80
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AA036 33,400 TDR 10.50 — 10.50 9.70
CK3BA036 33,400 TDR 10.50 — 10.50 9.70
CK3BA042 33,400 TDR 10.80 — 10.80 9.75
CK5A/CK5BA036 33,400 TDR 10.50 — 10.50 9.70
CK5A/CK5BT036 33,400 TDR 10.50 — 10.50 9.70
CK5A/CK5BW036 33,400 TDR 10.50 — 10.50 9.75
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 33,400 TDR 10.80 — 10.80 9.80
CC5A/CD5AW042 33,400 TDR 10.80 — 10.80 9.75
CD5AW036 33,400 TDR 10.50 — 10.50 9.75
CK3BA042 33,400 TDR 10.80 — 10.80 9.85
CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 9.85
CK5A/CK5BT042 33,400 TDR 10.80 — 10.80 9.85
CK5A/CK5BW036 33,400 TDR 10.50 — 10.50 9.80
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 33,400 TDR 10.80 — 10.80 9.75
CC5A/CD5AW042 33,400 TDR 10.80 — 10.80 9.70
CD5AW036 33,400 TDR 10.50 — 10.50 9.65
CK3BA042 33,400 TDR 10.80 — 10.80 9.75
CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 9.75
CK5A/CK5BT042 33,400 TDR 10.80 — 10.80 9.75
CK5A/CK5BW036 33,400 TDR 10.50 — 10.50 9.70
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 33,400 TDR 10.80 — 10.80 9.95
CC5A/CD5AW042 33,400 TDR 10.80 — 10.80 9.90
CD5AW036 33,400 TDR 10.50 — 10.50 9.90
—12—
COMBINATION RATINGS Continued
See notes on page 14.
UNIT
SIZE-SERIES INDOOR
MODEL TOT. CAP.
BTUH
FACTORY-
SUPPLIED
ENHANCE-
MENT STANDARD
RATING
BRYANT GAS
FURNACE OR
ACCESSORY
TDR† ACCESSORY
TXV‡ EERA
036-A, B, D, E
CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 10.00
CK5A/CK5BT042 33,400 TDR 10.80 — 10.80 10.00
CK5A/CK5BW036 33,400 TDR 10.50 — 10.50 9.95
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 33,400 TDR 10.80 — 10.80 9.90
CD5AW036 33,400 TDR 10.50 — 10.50 9.85
CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 9.95
CK5A/CK5BT042 33,400 TDR 10.80 — 10.80 9.95
CK5A/CK5BW036 33,400 TDR 10.50 — 10.50 9.90
042-A, B, C
CC5A/CD5AA042* 40,000 NONE 10.00 10.10 10.10 9.00
CC5A/CD5AC048 39,500 NONE 10.00 10.10 10.10 8.95
CC5A/CD5AW042 40,000 NONE 10.00 10.10 10.10 9.00
CC5A/CD5AW048 40,000 NONE 10.00 10.10 10.10 9.00
CD5AA048 40,000 NONE 10.00 10.10 10.10 9.00
CE3AA042 39,500 NONE 10.00 10.10 10.10 8.95
CE3AA048 40,500 NONE 10.00 10.10 10.10 9.10
CK3BA042 40,000 NONE 10.00 10.10 10.10 9.00
CK3BA048 40,000 NONE 10.00 10.10 10.10 9.00
CK5A/CK5BA042 40,000 NONE 10.00 10.10 10.10 9.05
CK5A/CK5BA048 40,000 NONE 10.00 10.10 10.10 9.00
CK5A/CK5BN042 39,000 NONE 10.00 10.10 10.10 9.05
CK5A/CK5BN048 39,000 NONE 10.00 10.10 10.10 9.00
CK5A/CK5BW048 40,000 NONE 10.00 10.10 10.10 9.00
F(A,B)4AN(F,B)042 40,000 TDR 10.00 — 10.00 9.00
F(A,B)4AN(F,B)048 41,000 TDR 10.10 — 10.10 9.00
FC4BN(F,B)042 40,000 TDR&TXV 10.00 — — 8.90
FC4BN(F,B)048 41,000 TDR&TXV 10.10 — — 9.00
FC4BNB054 41,500 TDR&TXV 10.50 — — 8.90
FG3AAA048 40,000 NONE 10.00 10.10 10.10 9.00
FK4CNF003 40,000 TDR&TXV 10.50 — — 9.60
FK4CNF005 41,000 TDR&TXV 11.00 — — 9.95
FK4CNF006 41,500 TDR&TXV 11.00 — — 10.15
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 40,000 TDR 10.50 — 10.50 9.45
CC5A/CD5AC048 40,000 TDR 10.70 — 10.70 9.45
CC5A/CD5AW042 40,000 TDR 10.50 — 10.50 9.55
CC5A/CD5AW048 40,000 TDR 10.70 — 10.70 9.45
CD5AA048 40,000 TDR 10.70 — 10.70 9.45
CE3AA042 40,000 TDR 10.50 — 10.50 9.55
CE3AA048 40,000 TDR 10.70 — 10.70 9.45
CK3BA042 40,000 TDR 10.50 — 10.50 9.45
CK3BA048 40,000 TDR 10.70 — 10.70 9.45
CK5A/CK5BA042 40,000 TDR 10.50 — 10.50 9.55
CK5A/CK5BA048 40,000 TDR 10.70 — 10.70 9.45
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 40,000 TDR 10.50 — 10.50 9.60
CC5A/CD5AC048 40,000 TDR 10.70 — 10.70 9.60
CC5A/CD5AW042 40,000 TDR 10.50 — 10.50 9.60
CC5A/CD5AW048 40,000 TDR 10.70 — 10.70 9.60
CD5AA048 40,000 TDR 10.70 — 10.70 9.60
CE3AA042 40,000 TDR 10.50 — 10.50 9.45
CE3AA048 40,000 TDR 10.70 — 10.70 9.45
CK3BA042 40,000 TDR 10.50 — 10.50 9.45
CK3BA048 40,000 TDR 10.70 — 10.70 9.60
CK5A/CK5BA042 40,000 TDR 10.50 — 10.50 9.45
CK5A/CK5BW048 40,000 TDR 10.70 — 10.70 9.45
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 40,000 TDR 10.50 — 10.50 9.50
CC5A/CD5AC048 40,000 TDR 10.70 — 10.70 9.55
CC5A/CD5AW042 40,000 TDR 10.50 — 10.50 9.50
CC5A/CD5AW048 40,000 TDR 10.70 — 10.70 9.55
CD5AA048 40,000 TDR 10.70 — 10.70 9.55
CE3AA042 40,000 TDR 10.50 — 10.50 9.55
CE3AA048 40,000 TDR 10.70 — 10.70 9.55
CK3BA042 40,000 TDR 10.50 — 10.50 9.50
CK3BA048 40,000 TDR 10.70 — 10.70 9.50
CK5A/CK5BA042 40,000 TDR 10.50 — 10.50 9.50
CK5A/CK5BW048 40,000 TDR 10.70 — 10.70 9.55
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 40,000 TDR 10.50 — 10.50 9.30
CC5A/CD5AC048 40,000 TDR 10.70 — 10.70 9.45
CK3BA042 40,000 TDR 10.50 — 10.50 9.30
CK3BA048 40,000 TDR 10.70 — 10.70 9.45
CK5A/CK5BA042 40,000 TDR 10.50 — 10.50 9.30
CK5A/CK5BA048 40,000 TDR 10.70 — 10.70 9.45
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CK5A/CK5BA042 40,000 TDR 10.50 — 10.50 9.30
CK5A/CK5BA048 40,000 TDR 10.70 — 10.70 9.45
CK3BA042 40,000 TDR 10.50 — 10.50 9.30
CK3BA048 40,000 TDR 10.70 — 10.70 9.45
—13—
COMBINATION RATINGS Continued
See notes on page 14.
UNIT
SIZE-SERIES INDOOR
MODEL TOT. CAP.
BTUH
FACTORY-
SUPPLIED
ENHANCE-
MENT STANDARD
RATING
BRYANT GAS
FURNACE OR
ACCESSORY
TDR† ACCESSORY
TXV‡ EERA
042-A, B, C
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA042 40,000 TDR 10.50 — 10.50 9.45
CC5A/CD5AC048 40,000 TDR 10.70 — 10.70 9.45
CK3BA042 40,000 TDR 10.50 — 10.50 9.45
CK3BA048 40,000 TDR 10.70 — 10.70 9.45
CK5A/CK5BA042 40,000 TDR 10.50 — 10.50 9.45
CK5A/CK5BA048 40,000 TDR 10.70 — 10.70 9.45
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CK3BA042 40,000 TDR 10.50 — 10.50 9.45
CK3BA048 40,000 TDR 10.70 — 10.70 9.45
CK5A/CK5BA042 40,000 TDR 10.50 — 10.50 9.45
CK5A/CK5BW048 40,000 TDR 10.70 — 10.70 9.45
048-A, B, C
CC5A/CD5AA060 46,000 NONE 10.00 10.50 10.50 9.35
CC5A/CD5AC048 45,000 NONE 10.00 10.50 10.50 9.25
CC5A/CD5AW048 46,000 NONE 10.00 10.50 10.50 9.30
CC5A/CD5AW060 47,500 NONE 10.20 10.50 10.50 9.55
CD5A048* 46,000 NONE 10.00 10.50 10.50 9.30
CE3AA048 46,500 NONE 10.20 10.50 10.50 9.30
CE3AA060 48,000 NONE 10.20 10.50 10.50 9.50
CF5AA048 46,000 NONE 10.20 10.50 10.50 9.40
CK3BA048 46,000 NONE 10.00 10.50 10.50 9.30
CK3BA060 46,000 NONE 10.00 10.50 10.50 9.30
CK5A/CK5BA048 46,000 NONE 10.00 10.50 10.50 9.30
CK5A/CK5BA060 46,000 NONE 10.00 10.50 10.50 9.35
CK5A/CK5BN048 44,500 NONE 10.00 10.50 10.50 9.25
CK5A/CK5BW048 46,000 NONE 10.00 10.50 10.50 9.30
CK5A/CK5BX060 47,500 NONE 10.20 10.50 10.50 9.55
F(A,B)4AN(F,B)048 47,000 TDR 10.50 — 10.50 9.15
F(A,B)4AN(F,B)060 48,000 TDR 10.50 — 10.50 9.25
FB4ANB070 49,000 TDR 11.00 — 11.00 9.55
FC4BN(F,B)048 47,000 TDR&TXV 10.50 — — 9.15
FC4BN(F,B)060 47,500 TDR&TXV 10.50 — — 9.25
FC4BNB054 48,500 TDR&TXV 11.00 — — 9.55
FC4BNB070 48,500 TDR&TXV 11.00 — — 9.50
FG3AA048 46,000 NONE 10.00 10.50 10.50 9.20
FG3AA060 47,000 NONE 10.20 10.50 10.50 9.35
FK4CNF005 48,000 TDR&TXV 11.50 — — 9.90
FK4CNF006 49,000 TDR 11.50 — 11.50 10.20
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE
CC5A/CD5AC048 45,500 TDR 10.50 — 10.50 9.35
CC5A/CD5AW048 45,500 TDR 10.50 — 10.50 9.35
CD5AA048 45,500 TDR 10.50 — 10.50 9.35
CE3AA048 45,500 TDR 10.50 — 10.50 9.60
CE3AA060 46,000 TDR 11.00 — 11.00 9.60
CK3BA048 45,500 TDR 10.50 — 10.50 9.35
CK3BA060 45,500 TDR 11.00 — 11.00 9.35
CK5A/CK5BA048 45,500 TDR 10.50 — 10.50 9.35
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 45,500 TDR 11.00 — 11.00 9.20
CC5A/CD5AW048 45,500 TDR 11.00 — 11.00 9.60
CC5A/CD5AW060 46,000 TDR 11.50 — 11.50 9.90
CD5AA048 45,500 TDR 11.00 — 11.00 9.60
CD5AC048 45,500 TDR 11.00 — 11.00 9.60
CE3AA048 45,500 TDR 11.00 — 11.00 9.60
CE3AA060 46,000 TDR 11.50 — 11.50 9.60
CK3BA048 45,500 TDR 11.00 — 11.00 9.35
CK3BA060 45,500 TDR 11.00 — 11.00 9.35
CK5A/CK5BA060 45,500 TDR 11.00 — 11.00 9.90
CK5A/CK5BW048 45,500 TDR 11.00 — 11.00 9.60
CK5A/CK5BX060 46,000 TDR 11.00 — 11.00 9.60
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 45,500 TDR 11.00 — 11.00 9.55
CC5A/CD5AC048 45,500 TDR 11.00 — 11.00 9.55
CC5A/CD5AW048 45,500 TDR 11.00 — 11.00 9.55
CC5A/CD5AW060 46,000 TDR 11.00 — 11.00 9.80
CD5AA048 45,500 TDR 11.00 — 11.00 9.55
CE3AA048 45,500 TDR 11.00 — 11.00 9.55
CE3AA060 46,000 TDR 11.50 — 11.50 9.80
CK3BA048 45,500 TDR 11.00 — 11.00 9.55
CK3BA060 45,500 TDR 11.00 — 11.00 9.80
CK5A/CK5BA060 45,500 TDR 11.00 — 11.00 9.80
CK5A/CK5BW048 45,500 TDR 11.00 — 11.00 9.55
CK5A/CK5BX060 46,000 TDR 11.00 — 11.00 9.80
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CC5A/CD5AW048 45,500 TDR 10.50 — 10.50 9.05
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AC048 45,500 TDR 10.80 — 10.80 9.30
CK5A/CK5BA048 45,500 TDR 10.50 — 10.50 9.30
—14—
COMBINATION RATINGS Continued
* Tested Combination.
† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the
394HAD.
‡ TXV must be hard shutoff type; based on computer simulation.
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other com-
binations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Minimum outdoor operating ambient in cooling mode is 55°F (12.8°C), maximum 125°F (51.7°C).
UNIT
SIZE-SERIES INDOOR
MODEL TOT. CAP.
BTUH
FACTORY-
SUPPLIED
ENHANCE-
MENT STANDARD
RATING
BRYANT GAS
FURNACE OR
ACCESSORY
TDR† ACCESSORY
TXV‡ EERA
048-A, B, C
CK3BA048 45,500 TDR 10.50 — 10.50 9.30
CK3BA060 45,500 TDR 11.00 — 11.00 9.15
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CK3BA048 45,500 TDR 10.50 — 10.50 9.30
CK3BA060 45,500 TDR 11.00 — 11.00 9.15
CK5A/CK5BA048 45,500 TDR 10.50 — 10.50 9.30
CK5A/CK5BA060 45,500 TDR 10.50 — 10.50 9.15
CK5A/CK5BX060 46,000 TDR 11.00 — 11.00 9.15
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 46,000 TDR 10.50 — 10.50 9.15
CC5A/CD5AC048 45,500 TDR 10.80 — 10.80 9.30
CK3BA048 45,500 TDR 10.80 — 10.80 9.30
CK3BA060 45,500 TDR 11.00 — 11.00 9.15
CK5A/CK5BA048 45,500 TDR 10.80 — 10.80 9.30
CK5A/CK5BA060 45,500 TDR 10.50 — 10.50 9.15
CK5A/CK5BX060 46,000 TDR 11.00 — 11.00 9.15
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CK3BA048 45,500 TDR 10.80 — 10.80 9.30
CK3BA060 45,500 TDR 11.00 — 11.00 9.15
CK5A/CK5BA060 45,500 TDR 10.50 — 10.50 9.15
CK5A/CK5BW048 45,500 TDR 10.80 — 10.80 9.30
CK5A/CK5BX060 46,000 TDR 11.00 — 11.00 9.15
060-A, B, E
CC5A/CD5AA060 54,500 NONE 10.00 10.50 10.50 9.25
CC5A/CD5AW060* 57,000 NONE 10.00 10.50 10.50 9.40
CE3AA060 57,500 NONE 10.00 10.50 10.50 9.50
CK5A/CK5BA060 54,500 NONE 10.00 10.50 10.50 9.25
CK5A/CK5BN060 54,500 NONE 10.00 10.50 10.50 9.50
CK5A/CK5BX060 57,000 NONE 10.00 10.50 10.50 9.50
CK3BA060 54,500 NONE 10.00 10.50 10.50 9.50
F(A,B)4AN(F,B)060 57,500 TDR 10.00 — 10.00 9.00
FB4ANB070 58,000 TDR 10.50 — 10.50 9.35
FC4BN(F,B)060 57,000 TDR&TXV 10.00 — — 9.00
FC4BNB070 58,000 TDR&TXV 10.50 — — 9.35
FG3AAA060 56,500 NONE 10.00 10.20 10.20 9.35
FK4CNB006 58,000 TDR&TXV 11.50 — — 10.00
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 54,500 TDR 10.70 — 10.70 9.40
CC5A/CD5AW060 54,500 TDR 10.70 — 10.70 9.65
CK3BA060 54,500 TDR 10.70 — 10.70 9.50
CK5A/CK5BA060 54,500 TDR 10.70 — 10.70 9.25
CK5A/CK5BX060 57,000 TDR 10.70 — 10.70 9.40
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 54,500 TDR 10.70 — 10.70 9.20
CC5A/CD5AW060 54,500 TDR 10.70 — 10.70 9.50
CK3BA060 54,500 TDR 10.70 — 10.70 9.50
CK5A/CK5BA060 54,500 TDR 10.70 — 10.70 9.25
CK5A/CK5BX060 54,500 TDR 10.70 — 10.70 9.40
—15—
DETAILED COOLING CAPACITIES*
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C018-A, D Outdoor Section With CC5A/CD5AA018 Indoor Section
525
72 21.0 10.0 1.77 19.9 9.58 1.88 18.7 9.11 1.98 17.4 8.65 2.09 16.2 8.18 2.18 14.9 7.73 2.27
67 19.1 12.3 1.71 18.0 11.9 1.81 16.8 11.4 1.91 15.7 10.9 2.01 14.5 10.4 2.09 13.4 9.96 2.17
62 17.2 14.6 1.65 16.2 14.1 1.75 15.1 13.6 1.84 14.1 13.0 1.93 13.0 12.5 2.01 12.0 11.9 2.08
57 15.9 15.9 1.61 15.1 15.1 1.71 14.3 14.3 1.81 13.5 13.5 1.90 12.7 12.7 1.99 11.9 11.9 2.07
600
72 21.5 10.4 1.82 20.3 9.97 1.92 19.0 9.50 2.03 17.8 9.02 2.13 16.4 8.55 2.23 15.2 8.09 2.32
67 19.5 13.0 1.75 18.4 12.5 1.86 17.2 12.0 1.96 16.0 11.5 2.05 14.8 11.1 2.14 13.6 10.6 2.22
62 17.7 15.5 1.70 16.6 15.0 1.79 15.5 14.4 1.89 14.4 13.8 1.98 13.3 13.2 2.06 12.3 12.3 2.14
57 16.6 16.6 1.67 15.8 15.8 1.77 14.9 14.9 1.87 14.1 14.1 1.96 13.2 13.2 2.05 12.3 12.3 2.14
675
72 21.9 10.8 1.86 20.7 10.4 1.97 19.4 9.86 2.07 18.0 9.39 2.18 16.7 8.90 2.27 15.3 8.44 2.36
67 19.9 13.7 1.80 18.7 13.2 1.90 17.5 12.7 2.00 16.3 12.2 2.09 15.0 11.7 2.18 13.8 11.2 2.26
62 18.0 16.4 1.74 16.9 15.8 1.84 15.8 15.2 1.93 14.6 14.5 2.02 13.6 13.6 2.11 12.7 12.7 2.20
57 17.2 17.2 1.71 16.3 16.3 1.82 15.4 15.4 1.92 14.5 14.5 2.01 13.6 13.6 2.11 12.7 12.7 2.20
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 018 1.00 1.00 FK4CNF 001 1.02 0.93
024 1.02 1.01 002 1.02 0.93
CC5A/CD5AW 024 1.02 1.01 COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE
CE3AA 024 1.03 1.01 CC5A/CD5AA 018 1.00 0.91
CF5AA 024 1.03 1.01 024 1.02 0.92
CK3BA 024 1.02 1.02 CK3BA 024 1.02 0.92
CK5A/CK5BA 018 1.00 1.01 CK5A/CK5BA 018 1.00 0.92
024 1.02 1.02 024 1.02 0.92
CK5A/CK5BW 024 1.02 1.02 COILS + 355MAV042060 VARIABLE-SPEED FURNACE
F(A,B)4AN(F,C) 018 0.98 0.99 CC5A/CD5AW 024 1.02 0.95
024 1.02 1.01 CK3BA 024 1.02 0.96
FC4BNF 024 1.02 1.01 CK5A/CK5BW 024 1.02 0.96
FF1(B,C,D)NA 018 1.00 0.97 COILS + 355MAV042080 VARIABLE-SPEED FURNACE
024 1.02 1.02 CC5A/CD5AW 024 1.02 0.95
FG3AAA 024 1.02 1.01 CK5A/CK5BW 024 1.02 0.95
—16—
DETAILED COOLING CAPACITIES* Continued
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C024-A, D Outdoor Section With CC5A/CD5AA024 Indoor Section
700
72 27.2 13.2 2.34 25.8 12.6 2.46 24.3 12.0 2.57 22.7 11.5 2.68 21.1 10.9 2.78 19.5 10.3 2.88
67 24.8 16.4 2.25 23.4 15.8 2.36 22.0 15.2 2.47 20.5 14.6 2.57 19.1 14.0 2.67 17.6 13.4 2.76
62 22.4 19.5 2.17 21.1 18.9 2.27 19.8 18.2 2.37 18.5 17.6 2.47 17.2 16.8 2.56 15.9 15.9 2.65
57 21.0 21.0 2.12 20.0 20.0 2.23 19.0 19.0 2.34 18.0 18.0 2.45 17.0 17.0 2.55 15.9 15.9 2.65
800
72 27.8 13.8 2.40 26.3 13.2 2.52 24.7 12.6 2.63 23.1 12.0 2.75 21.5 11.4 2.85 19.8 10.9 2.95
67 25.3 17.4 2.31 23.9 16.8 2.42 22.4 16.2 2.53 20.9 15.6 2.64 19.4 15.0 2.73 17.8 14.4 2.82
62 23.0 20.9 2.23 21.6 20.2 2.33 20.2 19.4 2.44 18.9 18.6 2.53 17.6 17.6 2.63 16.5 16.5 2.73
57 21.9 21.9 2.19 20.9 20.9 2.30 19.8 19.8 2.42 18.7 18.7 2.52 17.6 17.6 2.63 16.5 16.5 2.73
900
72 28.3 14.3 2.46 26.7 13.7 2.58 25.1 13.1 2.69 23.4 12.5 2.80 21.7 11.9 2.91 20.0 11.4 3.00
67 25.8 18.3 2.37 24.3 17.7 2.48 22.7 17.1 2.59 21.2 16.5 2.69 19.6 15.8 2.79 18.0 15.2 2.87
62 23.4 22.0 2.28 22.0 21.3 2.39 20.6 20.4 2.50 19.3 19.3 2.60 18.1 18.1 2.70 16.9 16.9 2.80
57 22.7 22.7 2.26 21.6 21.6 2.37 20.5 20.5 2.49 19.3 19.3 2.60 18.1 18.1 2.70 16.9 16.9 2.81
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 024 1.00 1.00 COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE
030 1.01 1.00 CC5A/CD5AA 024 1.00 0.92
CC5A/CD5AW 024 1.00 1.00 030 1.01 0.92
030 1.01 1.00 CC5A/CD5AW 030 1.01 0.92
CE3AA 024 1.01 1.00 CK3BA 024 1.00 0.93
030 1.03 1.01 030 1.01 0.93
CF5AA 024 1.01 1.00 CK5A/CK5BA 024 1.00 0.93
CK5A/CK5BA 024 1.00 1.00 030 1.01 0.93
030 1.01 1.01 CK5A/CK5BW 030 1.01 0.93
CK5A/CK5BW 024 1.00 1.00 COILS + 355MAV042040 VARIABLE-SPEED FURNACE
030 1.01 1.01 CC5A/CD5AW 030 1.01 0.95
CK3BA 024 1.00 1.00 CK5A/CK5BW 030 1.01 0.95
030 1.01 1.01 COILS + 355MAV042060 VARIABLE-SPEED FURNACE
F(A,B)4AN(F,C) 024 1.01 1.00 CC5A/CD5AW 024 1.00 0.95
030 1.03 1.00 030 1.01 0.95
FC4BNF 024 1.01 1.00 CK3BA 024 1.00 0.96
030 1.03 1.00 030 1.01 0.95
FF1(B,C,D)NA 024 1.01 1.01 CK5A/CK5BW 024 1.00 0.96
030 1.04 1.02 030 1.01 0.95
FG3AAA 024 0.98 0.99 COILS + 355MAV042080 VARIABLE-SPEED FURNACE
FK4CNF 001 1.04 0.93 CC5A/CD5AW 024 1.00 0.94
002 1.04 0.94 030 1.01 0.94
003 1.05 0.92 CK5A/CK5BW 024 1.00 0.94
— — — 030 1.01 0.94
—17—
DETAILED COOLING CAPACITIES* Continued
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C030-A, D Outdoor Section With CC5A/CD5AA030 Indoor Section
875
72 34.0 16.4 2.85 32.2 15.7 3.01 30.3 15.0 3.17 28.4 14.3 3.33 26.5 13.6 3.49 24.6 12.9 3.64
67 30.9 20.4 2.74 29.2 19.7 2.89 27.5 19.0 3.04 25.7 18.2 3.20 23.9 17.5 3.34 22.2 16.8 3.49
62 28.0 24.3 2.63 26.4 23.5 2.78 24.8 22.7 2.92 23.2 21.9 3.07 21.6 21.0 3.21 20.0 20.0 3.35
57 26.2 26.2 2.57 25.0 25.0 2.73 23.8 23.8 2.88 22.5 22.5 3.04 21.3 21.3 3.19 20.0 20.0 3.35
1000
72 34.8 17.1 2.93 32.8 16.4 3.09 30.9 15.7 3.25 28.9 15.0 3.41 26.9 14.3 3.57 24.9 13.6 3.72
67 31.6 21.6 2.82 29.8 20.9 2.97 28.0 20.1 3.12 26.2 19.4 3.27 24.3 18.7 3.42 22.5 17.9 3.57
62 28.6 25.9 2.71 27.0 25.1 2.86 25.3 24.2 3.00 23.7 23.2 3.15 22.1 22.1 3.30 20.7 20.7 3.45
57 27.3 27.3 2.66 26.0 26.0 2.82 24.7 24.7 2.98 23.4 23.4 3.13 22.1 22.1 3.29 20.7 20.7 3.45
1125
72 35.3 17.8 3.01 33.3 17.1 3.17 31.3 16.3 3.32 29.3 15.6 3.48 27.3 14.9 3.64 25.2 14.2 3.80
67 32.2 22.7 2.89 30.3 22.0 3.04 28.4 21.2 3.19 26.5 20.5 3.35 24.6 19.7 3.50 22.7 19.0 3.64
62 29.1 27.4 2.78 27.5 26.4 2.93 25.8 25.4 3.08 24.2 24.2 3.23 22.7 22.7 3.39 21.3 21.3 3.54
57 28.3 28.3 2.75 26.9 26.9 2.91 25.5 25.5 3.06 24.1 24.1 3.23 22.7 22.7 3.39 21.3 21.3 3.55
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 036 1.04 1.01 COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE
CC5A/CD5AW 030 1.00 1.00 CC5A/CD5AW 030 1.00 0.93
CD5A/CD5AA 030 1.00 1.00 CD5AW 036 1.04 0.93
CD5AW 036 1.04 1.01 CK5A/CK5BW 030 1.00 0.93
CE3AA 030 0.99 1.00 036 1.04 0.93
036 1.02 1.01 COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CF5AA 036 1.03 1.01 CC5A/CD5AW 030 1.00 0.97
CK3BA 030 1.00 1.00 CD5AW 036 1.04 0.97
036 1.04 1.01 CK5A/CK5BW 030 1.00 0.97
CK5A/CK5BA 030 1.00 1.00 036 1.04 0.97
036 1.04 1.01 COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CK5A/CK5BN 036 0.96 1.01 CC5A/CD5AA 036 1.04 0.97
CK5A/CK5BT 036 1.04 1.01 CC5A/CD5AW 030 1.00 0.97
CK5A/CK5BW 030 1.00 1.00 CK3BA 030 1.00 0.97
036 1.04 1.01 036 1.04 0.97
F(A,B)4AN(F,C) 030 0.99 1.00 CK5A/CK5BA 036 1.04 0.97
036 1.01 1.02 CK5A/CK5BT 036 1.04 0.97
FC4BNF 030 0.99 1.00 CK5A/CK5BW 030 1.00 0.97
036 1.01 1.02 COILS + 355MAV042080 VARIABLE-SPEED FURNACE
FF1(B,C,D)NA 030 1.00 1.02 CC5A/CD5AA 030 1.00 0.96
FG3AAA 036 1.00 1.00 CD5AW 036 1.04 0.97
FK4CNF 001 1.04 0.94 CK5A/CK5BW 030 1.00 0.96
002 1.04 0.94 036 1.04 0.97
003 1.05 0.93 COILS + 355MAV060080 VARIABLE-SPEED FURNACE
005 1.06 0.94 CC5A/CD5AW 030 1.00 0.97
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE CD5AW 036 1.04 0.97
CC5A/CD5AA 030 1.00 0.94 CK5A/CK5BW 030 1.00 0.97
036 1.04 0.94 036 1.04 0.97
CC5A/CD5AW 030 1.00 0.94 COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CK3BA 030 1.00 0.94 CC5A/CD5AW 030 1.00 0.95
036 1.04 0.94 CD5AW 036 1.04 0.95
CK5A/CK5BA 030 1.00 0.94 CK5A/CK5BW 030 1.00 0.95
036 1.04 0.94 036 1.04 0.95
CK5A/CK5BN 036 0.96 0.95 COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CK5A/CK5BT 036 1.04 0.94 CD5AW 036 1.04 0.96
CK5A/CK5BW 030 1.00 0.94 CK5A/CK5BW 036 1.04 0.96
—18—
DETAILED COOLING CAPACITIES* Continued
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C036-A, B, D, E Outdoor Section With CC5A/CD5AA036 Indoor Section
1050
72 41.3 20.5 3.41 39.1 19.6 3.61 36.8 18.8 3.81 34.5 18.0 4.00 32.2 17.1 4.19 29.9 16.3 4.38
67 37.6 25.8 3.28 35.5 25.0 3.47 33.4 24.1 3.65 31.3 23.3 3.84 29.1 22.4 4.02 27.0 21.6 4.20
62 34.1 31.0 3.16 32.2 30.0 3.33 30.3 29.0 3.51 28.4 28.0 3.69 26.6 26.6 3.87 25.0 25.0 4.06
57 32.8 32.8 3.10 31.2 31.2 3.30 29.7 29.7 3.49 28.2 28.2 3.68 26.6 26.6 3.87 25.0 25.0 4.06
1200
72 42.1 21.4 3.51 39.8 20.6 3.70 37.4 19.7 3.90 35.1 18.9 4.09 32.6 18.0 4.29 30.2 17.2 4.47
67 38.4 27.5 3.37 36.2 26.6 3.56 34.0 25.7 3.74 31.8 24.8 3.93 29.6 23.9 4.11 27.3 23.1 4.29
62 34.9 33.1 3.24 33.0 32.0 3.42 31.0 30.8 3.61 29.2 29.2 3.80 27.5 27.5 3.99 25.8 25.8 4.19
57 34.1 34.1 3.22 32.5 32.5 3.41 30.9 30.9 3.60 29.2 29.2 3.80 27.5 27.5 3.99 25.8 25.8 4.19
1350
72 42.7 22.3 3.59 40.3 21.4 3.79 37.9 20.6 3.98 35.4 19.7 4.18 33.0 18.9 4.37 30.5 18.1 4.56
67 38.9 29.0 3.45 36.7 28.1 3.64 34.4 27.2 3.83 32.1 26.3 4.01 29.8 25.4 4.19 27.6 24.5 4.37
62 35.6 34.9 3.33 33.6 33.5 3.52 31.8 31.8 3.71 30.1 30.1 3.91 28.3 28.3 4.10 26.5 26.5 4.30
57 35.2 35.2 3.32 33.5 33.5 3.51 31.8 31.8 3.71 30.1 30.1 3.91 28.3 28.3 4.11 26.5 26.5 4.30
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 036 1.00 1.00 COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
042 1.00 1.00 CC5A/CD5AA 042 0.99 0.92
CC5A/CD5AW 042 1.00 1.00 CD5AW 036 0.99 0.92
CD5AW 036 1.00 1.00 CK5A/CK5BA 042 0.99 0.92
CE3AA 036 0.99 1.00 CK5A/CK5BT 042 0.99 0.92
042 0.99 1.00 CK5A/CK5BW 036 0.99 0.92
CF5AA 036 0.99 1.00 COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
CK3BA 036 1.00 1.00 CC5A/CD5AA 042 0.99 0.92
042 1.00 1.00 CD5AW 036 0.99 0.93
CK5A/CK5BA 036 1.00 1.00 CK5A/CK5BA 042 0.99 0.92
042 1.00 1.00 CK5A/CK5BT 042 0.99 0.92
CK5A/CK5BN 036 0.93 0.97 CK5A/CK5BW 036 0.99 0.93
042 1.00 1.00 COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CK5A/CK5BT 036 1.00 1.00 CC5A/CD5AA 042 0.99 0.93
042 1.00 1.00 CD5AW 036 0.99 0.94
CK5A/CK5BW 036 1.00 1.00 CK5A/CK5BA 042 0.99 0.93
F(A,B)4AN(F,B,C) 042 1.00 1.01 CK5A/CK5BT 042 0.99 0.93
F(A,B)4AN(F,C) 036 0.98 1.01 COILS + 355MAV042060 VARIABLE-SPEED FURNACE
FC4BN(F,B) 042 1.00 1.01 CC5A/CD5AA 036 0.99 0.94
FC4BNB 054 1.03 1.01 CK3BA 036 0.99 0.94
FC4BNF 036 0.98 1.01 042 0.99 0.93
FG3AAA 036 0.96 0.99 CK5A/CK5BA 036 0.99 0.94
FK4CNB 006 1.04 0.93 CK5A/CK5BT 036 0.99 0.94
FK4CNF 001 0.98 0.94 CK5A/CK5BW 036 0.99 0.94
002 0.98 0.95 COILS + 355MAV042080 VARIABLE-SPEED FURNACE
003 0.99 0.92 CC5A/CD5AA 042 0.99 0.93
005 1.04 0.93 CC5A/CD5AW 042 0.99 0.92
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE CD5AW 036 0.99 0.93
CC5A/CD5AA 036 0.99 0.95 CK3BA 042 0.99 0.93
CK3BA 036 0.99 0.95 CK5A/CK5BA 042 0.99 0.93
CK5A/CK5BA 036 0.99 0.95 CK5A/CK5BT 042 0.99 0.93
CK5A/CK5BN 036 0.93 0.96 CK5A/CK5BW 036 0.99 0.93
CK5A/CK5BT 036 0.99 0.95 COILS + 355MAV060080 VARIABLE-SPEED FURNACE
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE CC5A/CD5AA 042 0.99 0.93
CC5A/CD5AA 042 0.99 0.93 CC5A/CD5AW 042 0.99 0.93
CC5A/CD5AW 042 0.99 0.93 CD5AW 036 0.99 0.94
CD5AW 036 0.99 0.94 CK3BA 042 0.99 0.93
CK3BA 042 0.99 0.93 CK5A/CK5BA 042 0.99 0.93
CK5A/CK5BA 042 0.99 0.93 CK5A/CK5BT 042 0.99 0.93
CK5A/CK5BT 042 0.99 0.93 CK5A/CK5BW 036 0.99 0.94
CK5A/CK5BW 036 0.99 0.94 — — —
—19—
DETAILED COOLING CAPACITIES* Continued
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C036-A, B, D, E Outdoor Section With CC5A/CD5AA036 Indoor Section Continued
1050
72 41.3 20.5 3.41 39.1 19.6 3.61 36.8 18.8 3.81 34.5 18.0 4.00 32.2 17.1 4.19 29.9 16.3 4.38
67 37.6 25.8 3.28 35.5 25.0 3.47 33.4 24.1 3.65 31.3 23.3 3.84 29.1 22.4 4.02 27.0 21.6 4.20
62 34.1 31.0 3.16 32.2 30.0 3.33 30.3 29.0 3.51 28.4 28.0 3.69 26.6 26.6 3.87 25.0 25.0 4.06
57 32.8 32.8 3.10 31.2 31.2 3.30 29.7 29.7 3.49 28.2 28.2 3.68 26.6 26.6 3.87 25.0 25.0 4.06
1200
72 42.1 21.4 3.51 39.8 20.6 3.70 37.4 19.7 3.90 35.1 18.9 4.09 32.6 18.0 4.29 30.2 17.2 4.47
67 38.4 27.5 3.37 36.2 26.6 3.56 34.0 25.7 3.74 31.8 24.8 3.93 29.6 23.9 4.11 27.3 23.1 4.29
62 34.9 33.1 3.24 33.0 32.0 3.42 31.0 30.8 3.61 29.2 29.2 3.80 27.5 27.5 3.99 25.8 25.8 4.19
57 34.1 34.1 3.22 32.5 32.5 3.41 30.9 30.9 3.60 29.2 29.2 3.80 27.5 27.5 3.99 25.8 25.8 4.19
1350
72 42.7 22.3 3.59 40.3 21.4 3.79 37.9 20.6 3.98 35.4 19.7 4.18 33.0 18.9 4.37 30.5 18.1 4.56
67 38.9 29.0 3.45 36.7 28.1 3.64 34.4 27.2 3.83 32.1 26.3 4.01 29.8 25.4 4.19 27.6 24.5 4.37
62 35.6 34.9 3.33 33.6 33.5 3.52 31.8 31.8 3.71 30.1 30.1 3.91 28.3 28.3 4.10 26.5 26.5 4.30
57 35.2 35.2 3.32 33.5 33.5 3.51 31.8 31.8 3.71 30.1 30.1 3.91 28.3 28.3 4.11 26.5 26.5 4.30
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
COILS + 355MAV060100 VARIABLE-SPEED FURNACE COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA 042 0.99 0.92 CC5A/CD5AA 042 0.99 0.92
CC5A/CD5AW 042 0.99 0.92 CD5AW 036 0.99 0.92
CD5AW 036 0.99 0.92 CK5A/CK5BA 042 0.99 0.92
CK5A/CK5BA 042 0.99 0.92 CK5A/CK5BT 042 0.99 0.92
CK5A/CK5BT 042 0.99 0.92 CK5A/CK5BW 036 0.99 0.92
CK5A/CK5BW 036 0.99 0.92 — — —
—20—
DETAILED COOLING CAPACITIES* Continued
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C042-A, B, C Outdoor Section With CC5A/CD5AA042 Indoor Section
1225
72 48.6 23.6 4.08 45.9 22.6 4.35 43.2 21.6 4.60 40.5 20.6 4.85 37.7 19.6 5.08 34.8 18.5 5.31
67 44.2 29.5 3.92 41.8 28.4 4.17 39.3 27.4 4.41 36.7 26.3 4.64 34.1 25.3 4.86 31.2 24.2 5.06
62 40.2 35.2 3.77 37.9 34.0 4.01 35.5 32.9 4.23 33.2 31.7 4.45 30.8 30.3 4.65 28.2 28.2 4.86
57 37.8 37.8 3.69 36.1 36.1 3.93 34.3 34.3 4.17 32.5 32.5 4.40 30.5 30.5 4.63 28.2 28.2 4.86
1400
72 49.6 24.7 4.19 46.8 23.6 4.45 44.0 22.6 4.71 41.1 21.6 4.96 38.2 20.5 5.20 35.3 19.5 5.42
67 45.2 31.2 4.03 42.6 30.2 4.28 40.0 29.1 4.52 37.4 28.0 4.75 34.7 27.0 4.97 31.8 25.8 5.17
62 41.1 37.5 3.88 38.7 36.3 4.11 36.3 35.0 4.35 34.0 33.6 4.57 31.7 31.7 4.78 29.3 29.3 5.01
57 39.4 39.4 3.82 37.6 37.6 4.07 35.7 35.7 4.31 33.7 33.7 4.55 31.7 31.7 4.78 29.3 29.3 5.01
1575
72 50.4 25.6 4.29 47.5 24.6 4.55 44.6 23.5 4.81 41.6 22.5 5.06 38.6 21.5 5.30 35.6 20.4 5.52
67 46.0 32.9 4.13 43.3 31.8 4.38 40.6 30.8 4.62 37.8 29.7 4.85 35.0 28.6 5.07 32.1 27.4 5.27
62 41.8 39.7 3.98 39.4 38.3 4.22 37.0 36.7 4.45 34.8 34.8 4.68 32.6 32.6 4.92 30.3 30.3 5.15
57 40.8 40.8 3.94 38.8 38.8 4.19 36.8 36.8 4.44 34.8 34.8 4.69 32.6 32.6 4.92 30.3 30.3 5.15
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 042 1.00 1.00 CD5AA 048 1.00 0.93
CC5A/CD5AC 048 0.99 1.00 CE3AA 042 1.00 0.94
CC5A/CD5AW 042 1.00 1.00 048 1.00 0.94
048 1.00 1.00 CK3BA 042 1.00 0.93
CD5A/CD5BA 048 1.00 1.00 048 1.00 0.93
CE3AA 042 0.99 1.00 CK5A/CK5BA 042 1.00 0.93
048 1.01 1.01 CK5A/CK5BW 048 1.00 0.93
CK3BA 042 1.00 1.00 COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
048 1.00 1.00 CC5A/CD5AA 042 1.00 0.94
CK5A/CK5BA 042 1.00 1.00 CC5A/CD5AC 048 1.00 0.93
048 1.00 1.00 CC5A/CD5AW 042 1.00 0.94
CK5A/CK5BN 042 0.98 1.00 048 1.00 0.94
048 0.98 1.00 CD5AA 048 1.00 0.94
CK5A/CK5BW 048 1.00 1.00 CE3AA 042 1.00 0.95
F(A,B)4AN(F,B) 042 1.00 1.01 048 1.00 0.95
048 1.02 1.02 CK3BA 042 1.00 0.93
FC4BN(F,B) 042 1.00 1.02 048 1.00 0.93
048 1.02 1.02 CK5A/CK5BA 042 1.00 0.93
FC4BNB 054 1.04 1.02 CK5A/CK5BW 048 1.00 0.93
FG3AAA 048 1.00 1.00 COILS + 355MAV042040 VARIABLE-SPEED FURNACE
FK4CNF 003 1.00 0.94 CC5A/CD5AA 042 1.00 0.95
005 1.02 0.96 CC5A/CD5AC 048 1.00 0.93
006 1.04 0.95 CC5A/CD5AW 042 1.00 0.95
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE 048 1.00 0.93
CC5A/CD5AA 042 1.00 0.95 COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AC 048 1.00 0.93 CC5A/CD5AA 042 1.00 0.95
CC5A/CD5AW 042 1.00 0.94 CC5A/CD5AC 048 1.00 0.93
048 1.00 0.94 CC5A/CD5AW 042 1.00 0.95
CD5A/CD5BA 048 1.00 0.94 048 1.00 0.93
CE3AA 042 1.00 0.95 CK3BA 042 1.00 0.95
048 1.00 0.95 CK5A/CK5BN 042 0.98 0.95
CK3BA 042 1.00 0.95 COILS + 355MAV042080 VARIABLE-SPEED FURNACE
048 1.00 0.95 CC5A/CD5AA 042 1.00 0.95
CK5A/CK5BA 042 1.00 0.95 CC5A/CD5AC 048 1.00 0.93
048 1.00 0.95 CC5A/CD5AW 042 1.00 0.95
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE 048 1.00 0.93
CC5A/CD5AA 042 1.00 0.93 CK3BA 042 1.00 0.95
CC5A/CD5AC 048 1.00 0.92 048 1.00 0.95
CC5A/CD5AW 042 1.00 0.93 CK5A/CK5BA 042 1.00 0.95
048 1.00 0.93 048 1.00 0.95
—21—
DETAILED COOLING CAPACITIES* Continued
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C042-A, B, C Outdoor Section With CC5A/CD5AA042 Indoor Section Continued
1225
72 48.6 23.6 4.08 45.9 22.6 4.35 43.2 21.6 4.60 40.5 20.6 4.85 37.7 19.6 5.08 34.8 18.5 5.31
67 44.2 29.5 3.92 41.8 28.4 4.17 39.3 27.4 4.41 36.7 26.3 4.64 34.1 25.3 4.86 31.2 24.2 5.06
62 40.2 35.2 3.77 37.9 34.0 4.01 35.5 32.9 4.23 33.2 31.7 4.45 30.8 30.3 4.65 28.2 28.2 4.86
57 37.8 37.8 3.69 36.1 36.1 3.93 34.3 34.3 4.17 32.5 32.5 4.40 30.5 30.5 4.63 28.2 28.2 4.86
1400
72 49.6 24.7 4.19 46.8 23.6 4.45 44.0 22.6 4.71 41.1 21.6 4.96 38.2 20.5 5.20 35.3 19.5 5.42
67 45.2 31.2 4.03 42.6 30.2 4.28 40.0 29.1 4.52 37.4 28.0 4.75 34.7 27.0 4.97 31.8 25.8 5.17
62 41.1 37.5 3.88 38.7 36.3 4.11 36.3 35.0 4.35 34.0 33.6 4.57 31.7 31.7 4.78 29.3 29.3 5.01
57 39.4 39.4 3.82 37.6 37.6 4.07 35.7 35.7 4.31 33.7 33.7 4.55 31.7 31.7 4.78 29.3 29.3 5.01
1575
72 50.4 25.6 4.29 47.5 24.6 4.55 44.6 23.5 4.81 41.6 22.5 5.06 38.6 21.5 5.30 35.6 20.4 5.52
67 46.0 32.9 4.13 43.3 31.8 4.38 40.6 30.8 4.62 37.8 29.7 4.85 35.0 28.6 5.07 32.1 27.4 5.27
62 41.8 39.7 3.98 39.4 38.3 4.22 37.0 36.7 4.45 34.8 34.8 4.68 32.6 32.6 4.92 30.3 30.3 5.15
57 40.8 40.8 3.94 38.8 38.8 4.19 36.8 36.8 4.44 34.8 34.8 4.69 32.6 32.6 4.92 30.3 30.3 5.15
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA 042 1.00 0.94
CK5A/CK5BA 042 1.00 0.95 048 1.00 0.94
048 1.00 0.95 CK5A/CK5BA 042 1.00 0.94
CK3BA 042 1.00 0.95 048 1.00 0.94
048 1.00 0.95 COILS + 355MAV060120 VARIABLE-SPEED FURNACE
COILS + 355MAV060100 VARIABLE-SPEED FURNACE CK3BA 042 1.00 0.94
CC5A/CD5AA 042 1.00 0.94 048 1.00 0.94
CC5A/CD5AC 048 1.00 0.93 CK5A/CK5BA 042 1.00 0.94
CC5A/CD5AW 042 1.00 0.94 CK5A/CK5BW 048 1.00 0.94
048 1.00 0.93 — — —
—22—
DETAILED COOLING CAPACITIES* Continued
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C048-A, B, C Outdoor Section With CD5AA048 Indoor Section
1400
72 54.3 26.2 4.17 51.9 25.3 4.65 49.5 24.4 5.18 47.0 23.5 5.75 44.4 22.6 6.35 41.8 21.6 6.99
67 49.6 32.8 4.07 47.4 31.8 4.55 45.2 30.9 5.06 42.9 30.0 5.61 40.5 29.0 6.21 38.1 28.0 6.83
62 45.2 39.2 3.99 43.2 38.2 4.45 41.1 37.2 4.95 39.0 36.1 5.49 36.8 35.0 6.07 34.4 33.6 6.66
57 42.4 42.4 3.94 40.9 40.9 4.41 39.3 39.3 4.91 37.7 37.7 5.45 36.0 36.0 6.03 33.9 33.9 6.64
1600
72 55.4 27.4 4.28 52.9 26.5 4.76 50.4 25.5 5.29 47.8 24.6 5.85 45.1 23.6 6.46 42.4 22.6 7.11
67 50.6 34.6 4.17 48.4 33.7 4.65 46.0 32.7 5.17 43.6 31.8 5.72 41.2 30.8 6.31 38.6 29.8 6.94
62 46.2 41.7 4.08 44.0 40.7 4.55 41.9 39.6 5.05 39.8 38.4 5.60 37.5 37.0 6.18 35.2 35.2 6.79
57 44.1 44.1 4.04 42.5 42.5 4.52 40.8 40.8 5.03 39.1 39.1 5.57 37.2 37.2 6.17 35.2 35.2 6.79
1800
72 56.2 28.4 4.37 53.7 27.5 4.85 51.1 26.5 5.38 48.4 25.6 5.96 45.6 24.6 6.56 42.8 23.6 7.21
67 51.5 36.4 4.27 49.1 35.5 4.74 46.7 34.5 5.26 44.2 33.5 5.82 41.6 32.5 6.41 39.0 31.5 7.04
62 46.9 44.0 4.17 44.8 42.8 4.64 42.6 41.6 5.15 40.4 40.2 5.70 38.3 38.3 6.29 36.2 36.2 6.92
57 45.5 45.5 4.15 43.8 43.8 4.62 42.0 42.0 5.14 40.2 40.2 5.69 38.3 38.3 6.29 36.2 36.2 6.92
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
CD5AA 048 1.00 1.00 CD5AA 048 0.99 1.00
CC5A/CD5AA 060 1.00 1.00 CD5AC 048 0.99 1.00
CC5A/CD5AC 048 0.98 0.99 CE3AA 048 0.99 1.01
CC5A/CD5AW 048 1.00 1.00 060 1.00 1.01
060 1.03 1.01 CK3BA 048 0.99 0.94
CE3AA 048 1.01 1.00 060 0.99 0.95
060 1.04 1.01 CK5A/CK5BA 060 0.99 0.94
CF5AA 048 1.00 0.99 CK5A/CK5BW 048 0.99 0.94
CK3BA 048 1.00 1.00 CK5A/CK5BX 060 1.00 0.95
060 1.00 1.01 COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
CK5A/CK5BA 048 1.00 1.00 CC5A/CD5AA 060 0.99 1.02
060 1.00 1.01 CC5A/CD5AC 048 0.99 1.01
CK5A/CK5BN 048 0.97 0.98 CC5A/CD5AW 048 0.99 1.01
CK5A/CK5BW 048 1.00 1.00 060 1.00 1.02
CK5A/CK5BX 060 1.03 1.01 CD5AA 048 0.99 1.01
F(A,B)4AN(F,B) 048 1.02 1.02 CE3AA 048 0.99 1.02
060 1.04 1.04 060 1.00 1.02
FB4ANB 070 1.07 1.03 CK3BA 048 0.99 0.95
FB4CNF 006 1.07 1.01 060 0.99 0.95
FC4BN(F,B) 048 1.02 1.02 CK5A/CK5BA 060 0.99 0.95
060 1.03 1.03 CK5A/CK5BW 048 0.99 0.95
FC4BNB 054 1.05 1.02 CK5A/CK5BX 060 1.00 0.95
070 1.05 1.02 COILS + 355MAV042040 VARIABLE-SPEED FURNACE
FG3AA 048 1.00 1.00 CC5A/CD5AA 060 0.99 0.99
060 1.02 1.01 CC5A/CD5AC 048 0.99 0.98
FK4CNF 005 1.04 1.03 CC5A/CD5AW 048 0.99 0.98
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE 060 1.00 0.99
CC5A/CD5AA 060 0.99 1.02 COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AC 048 0.99 1.02 CC5A/CD5AA 060 0.99 0.99
CC5A/CD5AW 048 0.99 1.02 CC5A/CD5AC 048 0.99 0.98
060 1.00 1.03 CC5A/CD5AW 048 0.99 0.98
CD5A/CD5BA 048 0.99 1.02 060 1.00 0.99
CE3AA 048 0.99 1.03 COILS + 355MAV042080 VARIABLE-SPEED FURNACE
060 1.00 1.03 CC5A/CD5AA 060 1.00 0.97
CK3BA 048 0.99 0.97 CC5A/CD5AC 048 0.99 0.96
060 0.99 0.97 CC5A/CD5AW 048 0.99 0.96
CK5A/CK5BA 048 0.99 0.97 060 1.01 0.97
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE CK3BA 048 0.99 0.97
CC5A/CD5AA 060 0.99 1.01 060 0.99 0.98
CC5A/CD5AW 048 0.99 1.00 CK5A/CK5BA 048 0.99 0.97
060 1.00 1.01 — — —
—23—
DETAILED COOLING CAPACITIES* Continued
See notes on page 24.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C048-A, B, C Outdoor Section With CD5AA048 Indoor Section Continued
1400
72 54.3 26.2 4.17 51.9 25.3 4.65 49.5 24.4 5.18 47.0 23.5 5.75 44.4 22.6 6.35 41.8 21.6 6.99
67 49.6 32.8 4.07 47.4 31.8 4.55 45.2 30.9 5.06 42.9 30.0 5.61 40.5 29.0 6.21 38.1 28.0 6.83
62 45.2 39.2 3.99 43.2 38.2 4.45 41.1 37.2 4.95 39.0 36.1 5.49 36.8 35.0 6.07 34.4 33.6 6.66
57 42.4 42.4 3.94 40.9 40.9 4.41 39.3 39.3 4.91 37.7 37.7 5.45 36.0 36.0 6.03 33.9 33.9 6.64
1600
72 55.4 27.4 4.28 52.9 26.5 4.76 50.4 25.5 5.29 47.8 24.6 5.85 45.1 23.6 6.46 42.4 22.6 7.11
67 50.6 34.6 4.17 48.4 33.7 4.65 46.0 32.7 5.17 43.6 31.8 5.72 41.2 30.8 6.31 38.6 29.8 6.94
62 46.2 41.7 4.08 44.0 40.7 4.55 41.9 39.6 5.05 39.8 38.4 5.60 37.5 37.0 6.18 35.2 35.2 6.79
57 44.1 44.1 4.04 42.5 42.5 4.52 40.8 40.8 5.03 39.1 39.1 5.57 37.2 37.2 6.17 35.2 35.2 6.79
1800
72 56.2 28.4 4.37 53.7 27.5 4.85 51.1 26.5 5.38 48.4 25.6 5.96 45.6 24.6 6.56 42.8 23.6 7.21
67 51.5 36.4 4.27 49.1 35.5 4.74 46.7 34.5 5.26 44.2 33.5 5.82 41.6 32.5 6.41 39.0 31.5 7.04
62 46.9 44.0 4.17 44.8 42.8 4.64 42.6 41.6 5.15 40.4 40.2 5.70 38.3 38.3 6.29 36.2 36.2 6.92
57 45.5 45.5 4.15 43.8 43.8 4.62 42.0 42.0 5.14 40.2 40.2 5.69 38.3 38.3 6.29 36.2 36.2 6.92
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA 048 0.99 0.96
CK3BA 048 0.99 0.98 060 0.99 0.97
060 0.99 0.99 CK5A/CK5BA 048 0.99 0.96
CK5A/CK5BA 048 0.99 0.98 060 0.99 0.96
060 0.99 0.98 CK5A/CK5BX 060 1.00 0.97
CK5A/CK5BX 060 1.00 0.99 COILS + 355MAV060120 VARIABLE-SPEED FURNACE
COILS + 355MAV060100 VARIABLE-SPEED FURNACE CK3BA 048 0.99 0.96
CC5A/CD5AA 060 1.00 0.97 060 0.99 0.97
CC5A/CD5AC 048 0.99 0.96 CK5A/CK5BA 060 0.99 0.96
CC5A/CD5AW 048 0.99 0.96 CK5A/CK5BW 048 0.99 0.96
060 1.01 0.97 CK5A/CK5BX 060 1.00 0.97
—24—
DETAILED COOLING CAPACITIES* Continued
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.
** Unit kw is total of indoor and outdoor unit kilowatts.
EWB—Entering Wet Bulb
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**
Capacity
MBtuh† Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
561C060-A, B, E Outdoor Section With CC5A/CD5AW060 Indoor Section
1750
72 66.3 32.0 5.14 63.7 31.0 5.64 61.0 30.0 6.20 58.1 28.9 6.82 55.0 27.8 7.50 51.7 26.6 8.24
67 60.6 40.0 4.96 58.1 38.9 5.46 55.6 37.9 6.01 52.9 36.7 6.63 50.0 35.6 7.30 47.1 34.4 8.02
62 55.2 47.8 4.81 52.9 46.7 5.30 50.6 45.5 5.85 48.1 44.3 6.46 45.4 42.9 7.12 42.8 41.5 7.80
57 51.8 51.8 4.72 50.0 50.0 5.22 48.2 48.2 5.78 46.3 46.3 6.40 44.2 44.2 7.07 42.1 42.1 7.77
1800
72 66.6 32.3 5.17 64.0 31.3 5.67 61.2 30.3 6.23 58.3 29.2 6.85 55.2 28.1 7.53 51.9 26.9 8.27
67 60.8 40.4 4.99 58.4 39.4 5.48 55.8 38.3 6.04 53.1 37.2 6.65 50.2 36.0 7.33 47.2 34.8 8.05
62 55.5 48.4 4.83 53.2 47.3 5.33 50.8 46.1 5.88 48.2 44.8 6.49 45.6 43.5 7.14 42.9 42.0 7.83
57 52.2 52.2 4.75 50.4 50.4 5.25 48.6 48.6 5.81 46.6 46.6 6.43 44.5 44.5 7.11 42.4 42.4 7.81
2100
72 68.1 33.9 5.34 65.3 32.9 5.83 62.4 31.8 6.39 59.4 30.7 7.01 56.1 29.6 7.69 52.8 28.4 8.43
67 62.2 43.1 5.14 59.7 42.1 5.64 57.0 41.0 6.20 54.2 39.8 6.81 51.2 38.6 7.48 48.0 37.4 8.21
62 56.7 52.0 4.98 54.4 50.8 5.48 51.9 49.5 6.03 49.3 48.0 6.64 46.6 46.3 7.30 44.1 44.1 8.01
57 54.6 54.6 4.93 52.7 52.7 5.43 50.7 50.7 5.99 48.6 48.6 6.62 46.4 46.4 7.29 44.1 44.1 8.01
2250
72 68.7 34.6 5.41 65.9 33.6 5.91 62.9 32.6 6.47 59.8 31.4 7.09 56.5 30.3 7.77 53.1 29.1 8.51
67 62.8 44.4 5.22 60.2 43.4 5.71 57.5 42.3 6.27 54.6 41.1 6.89 51.5 39.9 7.56 48.3 38.6 8.28
62 57.3 53.7 5.05 54.9 52.4 5.55 52.4 51.0 6.10 49.8 49.3 6.71 47.2 47.2 7.38 44.8 44.8 8.11
57 55.6 55.6 5.01 53.7 53.7 5.51 51.6 51.6 6.08 49.5 49.5 6.70 47.2 47.2 7.38 44.8 44.8 8.11
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Unit
Size
Cooling Indoor
Section Unit
Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AW 060 1.00 1.00 FG3AAA 060 0.99 1.00
CC5A/CD5AA 060 0.96 0.97 FK4CNB 006 1.02 1.00
CE3AA 060 1.01 0.99 COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
CK3BA 060 0.96 1.00 CK3BA 060 0.96 0.95
CK5A/CK5BA 060 0.96 0.97 CK5A/CK5BA 060 0.96 0.95
CK5A/CK5BN 060 0.96 0.98 CK5A/CK5BX 060 1.00 0.95
CK5A/CK5BX 060 1.00 1.00 COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
F(A,B)4AN(F,B) 060 1.01 1.05 CK3BA 060 0.96 0.96
FB4ANB 070 1.02 1.03 CK5A/CK5BA 060 0.96 0.96
FC4BN(F,B) 060 1.00 1.04 CK5A/CK5BX 060 0.96 0.96
FC4BNB 070 1.02 1.02 — — —
—25—
CONDENSER ONLY RATINGS*
See notes on page 26.
SST
°F
CONDENSER ENTERING AIR TEMPERATURES °F
55 65 75 85 95 105 115 125
561C018-A, D
30 TCG 17.6 16.2 14.7 13.4 12.0 10.7 9.52 8.35
KW 1.37 1.49 1.58 1.66 1.73 1.77 1.80 1.82
SDT 75.6 86.1 96.4 106.0 116.0 126.0 136.0 146.0
35 TCG 19.6 18.1 16.6 15.1 13.6 12.3 10.9 9.68
KW 1.40 1.52 1.63 1.73 1.81 1.87 1.91 1.93
SDT 76.5 87.2 97.4 107.0 117.0 127.0 137.0 146.0
40 TCG 21.8 20.1 18.5 16.9 15.4 13.9 12.5 11.1
KW 1.42 1.56 1.68 1.79 1.88 1.96 2.01 2.05
SDT 77.6 88.4 98.6 109.0 119.0 128.0 138.0 147.0
45 TCG 24.1 22.3 20.6 18.9 17.2 15.6 14.1 12.6
KW 1.44 1.59 1.73 1.85 1.96 2.05 2.12 2.17
SDT 78.7 89.7 100.0 110.0 120.0 130.0 139.0 149.0
50 TCG 26.5 24.6 22.7 20.9 19.1 17.4 15.8 14.2
KW 1.46 1.62 1.77 1.91 2.03 2.14 2.22 2.29
SDT 79.8 91.0 102.0 112.0 122.0 131.0 141.0 150.0
55 TCG 29.0 27.0 25.0 23.1 21.2 19.4 17.6 15.9
KW 1.47 1.65 1.82 1.97 2.10 2.22 2.32 2.40
SDT 81.1 92.3 103.0 113.0 123.0 133.0 142.0 152.0
561C024-A, D
30 TCG 22.5 20.9 19.2 17.5 15.9 14.2 12.6 11.0
KW 1.83 1.95 2.05 2.14 2.21 2.26 2.29 2.29
SDT 70.0 82.2 93.6 104.0 115.0 125.0 135.0 145.0
35 TCG 24.9 23.2 21.5 19.7 17.9 16.2 14.5 12.8
KW 1.89 2.01 2.13 2.23 2.32 2.38 2.43 2.45
SDT 69.8 82.6 94.2 105.0 116.0 126.0 136.0 145.0
40 TCG 27.5 25.7 23.8 22.0 20.1 18.3 16.5 14.6
KW 1.94 2.08 2.21 2.32 2.42 2.50 2.57 2.60
SDT 69.5 82.9 95.0 106.0 117.0 127.0 137.0 146.0
45 TCG 30.1 28.3 26.3 24.4 22.4 20.5 18.5 16.6
KW 2.00 2.15 2.29 2.42 2.53 2.63 2.70 2.76
SDT 69.7 83.2 95.6 107.0 118.0 128.0 138.0 148.0
50 TCG 32.9 31.0 29.0 26.9 24.8 22.7 20.7 18.7
KW 2.07 2.22 2.37 2.51 2.64 2.75 2.84 2.91
SDT 70.3 83.4 96.3 108.0 119.0 129.0 139.0 149.0
55 TCG 35.8 33.8 31.8 29.6 27.3 25.1 23.0 20.9
KW 2.13 2.29 2.45 2.60 2.74 2.87 2.98 3.07
SDT 70.9 83.8 97.0 109.0 120.0 131.0 141.0 151.0
561C030-A, D
30 TCG 28.0 26.0 24.0 22.0 20.1 18.2 16.4 14.7
KW 2.21 2.35 2.48 2.61 2.72 2.82 2.91 2.98
SDT 77.5 87.5 97.4 107.0 117.0 127.0 136.0 146.0
35 TCG 31.1 28.9 26.7 24.6 22.6 20.6 18.6 16.8
KW 2.29 2.44 2.59 2.72 2.85 2.97 3.07 3.15
SDT 78.9 88.9 98.8 109.0 118.0 128.0 137.0 147.0
40 TCG 34.3 32.0 29.7 27.4 25.2 23.1 21.0 18.9
KW 2.38 2.54 2.70 2.85 2.99 3.11 3.23 3.33
SDT 80.5 90.6 100.0 110.0 120.0 129.0 139.0 148.0
45 TCG 37.7 35.2 32.8 30.4 28.0 25.7 23.4 21.2
KW 2.47 2.64 2.81 2.97 3.12 3.27 3.40 3.51
SDT 82.1 92.3 102.0 112.0 121.0 131.0 140.0 150.0
50 TCG 41.3 38.7 36.1 33.5 31.0 28.5 26.1 23.7
KW 2.56 2.75 2.92 3.10 3.27 3.42 3.57 3.70
SDT 83.9 94.0 104.0 114.0 123.0 133.0 142.0 151.0
55 TCG 45.1 42.3 39.5 36.8 34.1 31.4 28.8 26.3
KW 2.66 2.86 3.05 3.23 3.41 3.58 3.74 3.89
SDT 85.8 96.0 106.0 116.0 125.0 135.0 144.0 153.0
561C036-A, B, D, E
30 TCG 32.1 30.5 28.9 27.2 25.5 23.7 21.8 19.9
KW 2.33 2.57 2.84 3.11 3.40 3.68 3.95 4.21
SDT 78.6 89.0 99.3 109.0 120.0 129.0 139.0 149.0
35 TCG 35.2 33.5 31.8 30.0 28.2 26.3 24.3 22.3
KW 2.40 2.65 2.92 3.21 3.51 3.81 4.10 4.39
SDT 79.9 90.4 101.0 111.0 121.0 131.0 141.0 150.0
40 TCG 38.4 36.7 34.9 33.0 31.0 29.0 26.9 24.8
KW 2.47 2.72 3.00 3.30 3.61 3.93 4.25 4.56
SDT 81.3 91.9 102.0 112.0 123.0 132.0 142.0 152.0
45 TCG 41.8 40.0 38.1 36.1 34.0 31.8 29.7 27.4
KW 2.55 2.81 3.10 3.40 3.73 4.06 4.40 4.74
SDT 82.9 93.5 104.0 114.0 124.0 134.0 144.0 154.0
50 TCG 45.4 43.5 41.5 39.3 37.1 34.9 32.5 30.2
KW 2.63 2.90 3.19 3.51 3.84 4.20 4.55 4.91
SDT 84.6 95.3 106.0 116.0 126.0 136.0 146.0 155.0
55 TCG 49.2 47.2 45.0 42.8 40.4 38.0 35.5 33.0
KW 2.72 2.99 3.29 3.62 3.97 4.33 4.70 5.08
SDT 86.4 97.0 107.0 118.0 128.0 138.0 148.0 157.0
—26—
CONDENSER ONLY RATINGS* Continued
* ARI listing applies only to systems shown in Ratings and Performance table.
KW — Total Power (Kw)
SDT — Saturated Temperature Leaving Compressor (°F)
SST — Saturated Temperature Entering Compressor (°F)
TCG — Gross Cooling Capacity (1000 Btuh)
SST
°F
CONDENSER ENTERING AIR TEMPERATURES °F
55 65 75 85 95 105 115 125
561C042-A, B, C
30 TCG 37.9 36.1 34.2 32.1 30.0 27.8 25.6 23.3
KW 2.73 3.03 3.34 3.67 4.01 4.35 4.68 4.98
SDT 80.8 91.0 101.0 111.0 121.0 131.0 141.0 150.0
35 TCG 41.5 39.6 37.5 35.4 33.2 30.9 28.5 26.0
KW 2.82 3.12 3.45 3.79 4.15 4.51 4.87 5.21
SDT 82.5 92.7 103.0 113.0 123.0 133.0 142.0 152.0
40 TCG 45.3 43.3 41.1 38.9 36.5 34.1 31.5 28.9
KW 2.91 3.22 3.56 3.92 4.29 4.67 5.06 5.43
SDT 84.3 94.5 105.0 115.0 125.0 134.0 144.0 154.0
45 TCG 49.4 47.2 44.9 42.5 40.0 37.4 34.8 32.0
KW 3.01 3.33 3.68 4.05 4.44 4.84 5.25 5.65
SDT 86.3 96.5 107.0 117.0 127.0 136.0 146.0 156.0
50 TCG 53.6 51.2 48.8 46.3 43.6 40.9 38.1 35.2
KW 3.11 3.44 3.80 4.18 4.59 5.01 5.44 5.87
SDT 88.3 98.5 109.0 119.0 129.0 138.0 148.0 158.0
55 TCG 58.0 55.5 52.9 50.2 47.5 44.6 41.6 38.5
KW 3.22 3.56 3.93 4.32 4.74 5.18 5.63 6.09
SDT 90.4 101.0 111.0 121.0 131.0 140.0 150.0 160.0
561C048-A, B, C
30 TCG 42.6 40.8 38.9 36.9 34.8 32.7 30.5 28.3
KW 3.22 3.56 3.93 4.34 4.80 5.28 5.79 6.31
SDT 76.5 87.0 97.4 108.0 118.0 128.0 138.0 148.0
35 TCG 46.6 44.7 42.7 40.6 38.4 36.1 33.8 31.4
KW 3.28 3.61 3.99 4.41 4.87 5.37 5.89 6.44
SDT 77.7 88.2 98.6 109.0 119.0 129.0 139.0 149.0
40 TCG 50.9 48.8 46.7 44.4 42.1 39.7 37.2 34.7
KW 3.34 3.68 4.06 4.49 4.95 5.46 6.00 6.57
SDT 79.0 89.6 99.9 110.0 120.0 131.0 141.0 150.0
45 TCG 55.4 53.2 50.9 48.5 46.0 43.4 40.8 38.1
KW 3.42 3.75 4.14 4.57 5.04 5.56 6.11 6.70
SDT 80.4 91.0 101.0 112.0 122.0 132.0 142.0 152.0
50 TCG 60.1 57.8 55.3 52.8 50.1 47.4 44.5 41.7
KW 3.49 3.84 4.22 4.66 5.13 5.66 6.23 6.83
SDT 81.8 92.5 103.0 113.0 124.0 134.0 144.0 154.0
55 TCG 65.1 62.6 60.0 57.3 54.5 51.5 48.5 45.4
KW 3.58 3.93 4.32 4.75 5.24 5.77 6.34 6.96
SDT 83.4 94.1 105.0 115.0 125.0 135.0 145.0 155.0
561C060-A, B, E
30 TCG 52.8 50.6 48.2 45.8 43.3 40.6 37.9 35.2
KW 3.87 4.27 4.73 5.23 5.78 6.37 6.99 7.63
SDT 75.7 86.2 96.6 107.0 117.0 127.0 137.0 147.0
35 TCG 57.8 55.4 52.9 50.3 47.6 44.8 41.9 39.0
KW 3.94 4.35 4.81 5.32 5.87 6.48 7.12 7.79
SDT 76.9 87.5 97.9 108.0 118.0 129.0 139.0 148.0
40 TCG 63.0 60.5 57.8 55.1 52.2 49.2 46.1 43.0
KW 4.02 4.44 4.90 5.41 5.98 6.60 7.27 7.95
SDT 78.2 88.9 99.3 110.0 120.0 130.0 140.0 150.0
45 TCG 68.6 65.8 63.0 60.0 57.0 53.8 50.5 47.2
KW 4.12 4.53 5.00 5.52 6.09 6.72 7.41 8.12
SDT 79.6 90.3 101.0 111.0 121.0 132.0 142.0 152.0
50 TCG 74.4 71.5 68.5 65.3 62.1 58.7 55.2 51.5
KW 4.22 4.64 5.11 5.63 6.22 6.86 7.55 8.29
SDT 81.1 91.9 102.0 113.0 123.0 133.0 143.0 153.0
55 TCG 80.5 77.4 74.2 70.9 67.4 63.8 60.1 56.2
KW 4.33 4.75 5.23 5.76 6.35 7.00 7.70 8.46
SDT 82.7 93.6 104.0 115.0 125.0 135.0 145.0 155.0
—27—
SYSTEM DESIGN
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft.
6. For interconnecting refrigerant tube lengths between 50 and 175 ft, consult Residential Split Systems Long-Line Application Guideline available
from equipment distributor.
7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft.
8. If any refrigerant tubing is buried, provide a 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. may be
buried without further consideration. For buried lines longer than 3 ft, consult your local distributor.
9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
—28—
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels PDS 561C.18.5
© 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 5256-108 11-99
GUIDE SPECIFICATIONS
GENERAL
System Description
Outdoor-mounted, air-cooled, split-system air conditioner unit
suitable for ground or rooftop installation. Unit consists of a her-
metic compressor, an air-cooled coil, propeller-type condenser
fan, and a control box. Unit will discharge supply air upward as
shown on contract drawings. Unit will be used in a refrigeration
circuit to match up to a packaged fan coil or coil unit.
Quality Assurance
Unit will be rated in accordance with the latest edition of ARI
Standard 210.
Unit will be certified for capacity, efficiency, and listed in the lat-
est ARI directory.
Unit construction will comply with latest edition of ANSI/
ASHRAE and with NEC.
Unit will be constructed in accordance with UL standards and
will carry the UL label of approval. Unit will have c-UL approval.
Unit cabinet will be capable of withstanding Federal Test
Method Standard No. 141 (Method 6061) 500-hr salt spray test.
Air-cooled condenser coils will be leak tested at 150 psig and
pressure tested at 300 psig.
Unit constructed in ISO 9001 approved facility.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only.
PRODUCTS
Equipment
Factory-assembled, single-piece, air-cooled air conditioner unit.
Contained within the unit enclosure will be all factory wiring, pip-
ing, controls, compressor, refrigerant charge (R22), and special
features required prior to field start-up.
Unit Cabinet
Unit cabinet will be constructed of galvanized steel, bonderized,
and coated with a powder coat paint.
Fans
Condenser fan will be direct-drive propeller type, discharging air
upward.
Air-Cooled, Split-System
Air Conditioner
561C
1-1/2 to 5 Tons Nominal
Condenser fan motors will be totally enclosed, 1-phase type
with class B insulation and permanently lubricated bearings.
Shafts will be corrosion resistant.
Fan blades will be statically and dynamically balanced.
Condenser fan openings will be equipped with PVC-coated
steel wire safety guards.
Compressor
Compressor will be hermetically sealed.
Compressor will be mounted on rubber vibration isolators.
Condenser Coil
Condenser coil will be air cooled.
Coil will be constructed of aluminum fins mechanically bonded
to copper tubes which are then cleaned, dehydrated, and
sealed.
Refrigeration Components
Refrigeration circuit components will include liquid line shutoff
valve with sweat connections, suction line shutoff valves with
sweat connections, system charge of R22 refrigerant, and com-
pressor oil.
Operating Characteristics
The capacity of the unit will meet or exceed _____ Btuh at a
suction temperature of _____ °F. The power consumption at full
load will not exceed _____ kw.
Combination of the unit and the evaporator or fan coil unit will
have a total net cooling capacity of _____ Btuh or greater at
conditions of _____ CFM entering air temperature at the evapo-
rator at _____ °F wet bulb and _____ °F dry bulb, and air enter-
ing the unit at _____ °F.
The system will have an SEER of _____ Btuh/watt or greater at
DOE conditions.
Electrical Requirements
Nominal unit electrical characteristics will be _____ v, single
phase, 60 hertz. The unit will be capable of satisfactory opera-
tion within voltage limits of _____ v to _____ v.
Unit electrical power will be single point connection.
Control circuit will be 24v.