Bryant Cc5A Users Manual

CD5A to the manual d96a12be-8779-4e27-9c63-69f578a2f00d

2015-02-02

: Bryant Bryant-Cc5A-Users-Manual-411827 bryant-cc5a-users-manual-411827 bryant pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadBryant Bryant-Cc5A-Users-Manual-  Bryant-cc5a-users-manual
Open PDF In BrowserView PDF
HEATING/COOLING
COIL

CC5A, CD5A
Sizes 018 thru 060

The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout
the life of a quality Bryant Air Conditioner or Heat Pump system.
Evaporator coils manufactured by Bryant and installed as part of
a total comfort system provide ARI rated performance ratings
and are additionally listed with UL, c-UL, and RADCO.
The CC5A is an uncased A-coil that provides flexibility for a wide
variety of field applications installed in either a factory manufactured accessory casing, or a field supplied plenum enclosure.
The CD5A is a cased A-coil that is housed in a durable, prepainted cabinet. The fully insulated cabinet provides for quiet,
efficient operation of the evaporator coil.
The coils are available in sizes 018 through 060 (1-1/2–5 tons).

COMMON FEATURES

CD5A

CC5A

Durable Condensate Pan—Each coil is equipped with a corrosion resistant condensate drain pan. The condensate drain pan
is designed with a slope to help ensure proper drainage,
improved moisture removal, and home comfort.
Brass Inserts—Every condensate pan features two 3/4 in.
female threaded brass insert connections. The Bryant unique
brass inserts provide for a leak-free condensate line connection
to prevent water damage.
Refrigerant Connections—The coils are provided with proven
sweat-connections for leak-free operation maintaining system
reliability.
Burst Pressures—These coils meet or exceed burst pressure
of 2100 psi which is at least three to five times the pressure they
will see in actual application.
External Piston Location—Provides easy access to the piston
metering device, for quick installations and standard service
procedures.
Liquid Line Bracket—Holds the piston body in place for quick,
safe piston access without needing a back-up wrench.
Neoprene Ring—The ring, installed inside the liquid line connection, is the best option for preventing refrigerant leaks and
future service calls. Neoprene works with both Puron® and R-22
Refrigerant.
Protective Tube Sheets—Protect the durable copper tubing
from being damaged during the manufacturing and installation
process.
Warranty—All Bryant coils feature a 1-year limited warranty
on parts, with additional extended warranties available for the
system.

CC5A FEATURES
Coil Support—Bryant provides a standard factory support for
the uncased coil. This provides precise, durable support in the
plenum for easier installations.
Face Plate—A unique Bryant feature that provides for a more
professional installation and prevents air leaks at the refrigerant
line connections.

CD5A FEATURES
Easy Serviceability—Every coil is designed to slide out of the
casing easily, for quick installations and service.

Form No. PDS CC5A.18.6

MODEL NUMBER NOMENCLATURE
C

D

5

A

X

A

018
018-1 1/2 Ton
024-2 Ton
030-2 1/2 Ton
Etc.

C-Coil

C-Piston, Uncased, A-Coil
D-Piston, Cased, A-Coil
E-Piston, Cased, Slab
F-Manufactured Home, Uncased, A-Coil w/ Piston
G-Manufactured Home, Uncased, A-Coil w/ TXV
K-Piston, Cased N-Coil

A-Standard
C-Compact
W-Wide
Position Not Used

3-Horizontal
5-Upflow/Downflow

014

Major Series Change

014-14 3/16 In. Casing Width
017-17 1/2 In. Casing Width
021-21 In. Casing Width
024-24 1/2 In. Casing Width
031-31 In. Casing Width

UNIT
AR

AIR
CO

Y

NING
ITIO
ND

MANUFACTUR
ER

Y

T
IFIED O ARI A
RT
S
C
CE

YING WITH
PL
OM

HE

MP
PU
AT

UNIT
AR

T
IFIED O ARI A
RT
S
C
CE

YING WITH
PL
OM

MANUFACTUR
ER

A98057

• CERTIFICATION • LISTING

®

A

EQ

RI

UIP M E NT

STA

NDARD

0
24

A

EQ

RI

UIP M E N T

STA

NDARD

• TESTING • INSPECTION

0
21

CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI

—2—

®

21″
(533.4)
1 1/8″
(28.6)

D

13/16″

19″
(482.6)

1 /2 ″

(20.6)

(12.7)

5/8″
(15.9)

E

C

2"
(50.8)
IN. SUCTION LINE

3/8″ LIQUID LINE
(9.5)
3/4″ NPT
7 1/2″
PLUGGED DRAIN
(190.5)
(19.1)

10 1/8″
(257.2)

2 1/8″
(54.0)

1 9/16″
(39.7)
3″
(76.2)

1 3 /8 ″
(34.9)

2 1 /8 ″
(54.0)
1 7/8″
(47.6)

3/4″ NPT DRAIN
(19.1)

A

RIGHT SIDE

FRONT

CASED COILS CD5AXA018, 024, 030, 036, 042, 048, CD5AXW024, 036, CD5AXC048
21 15/16″
(557.2)

1 1/8″
(28.6)

19″
(482.6)

1 /2 ″

D

13/16″

(12.7)

(20.6)

5/8″

(15.9)
1 7 /8 ″
(47.6)

2″
(50.8)

E IN.
SUCTION LINE
(15.88)
3/8″ LIQUID LINE
(9.5)
2 1/8″

C

10 1/8″
(257.2)

3/4″ (19.1) NPT
PLUGGED DRAIN

7 1/2″
(190.5)

(54.0)

2 1 /8 ″
(54.0)

1 /2 ″
(12.7)

1 3/8″
(34.9)

3/4″ NPT DRAIN
(19.1)

1 9/16″
(39.7)
3″
(76.2)

A

FRONT

LEFT SIDE

CASED COILS CD5AXW042, 048, 060, CD5AXA060
A98067

A

C

D

E

SHIPPING WEIGHT

UNIT

SERIES

In.

mm

In.

mm

In.

mm

In.

mm

Lb.

Kg.

CD5AXA018014

A

14-3/16

360.4

14-5/8

371.5

12-9/16

319.1

5/8

15.88

27

12.2

CD5AXA024014

A

14-3/16

360.4

14-5/8

371.5

12-9/16

319.1

5/8

15.88

29

13.2

CD5AXW024017

A

17-1/2

444.5

17

431.8

15-7/8

403.2

3/4

19.05

37

16.8

CD5AXA030014

A

14-3/16

360.4

17

431.8

12-9/16

319.1

3/4

19.05

32

14.5

CD5AXW030017

A

17-1/2

444.5

17

431.8

15-7/8

403.2

3/4

19.05

37

16.8

CD5AXA036017

A

17-1/2

444.5

20-1/2

520.7

15-7/8

403.2

3/4

19.05

43

19.5

CD5AXW036021

A

21

533.4

19

482.6

19-3/8

492.1

3/4

19.05

45

20.4

CD5AXA042021

A

21

533.4

20-1/2

520.7

19-3/8

492.1

7/8

22.23

45

20.4

CD5AXA048021

A

21

533.4

26-3/8

669.9

19-3/8

492.1

7/8

22.23

57

25.9

CD5AXC048021

A

21

533.4

22

558.8

19-3/8

492.1

7/8

22.23

48

21.8

CD5AXW042024

A

24-1/2

622.3

20-1/2

520.7

22-7/8

581.0

7/8

22.23

49

22.2

CD5AXW048024

A

24-1/2

622.3

22

558.8

22-7/8

581.0

7/8

22.23

53

24.0

CD5AXA060024

A

24-1/2

622.3

22

558.8

22-7/8

581.0

7/8

22.23

53

24.0

CD5AXW060031

A

31-1/2

800.1

22

558.8

29-7/8

758.8

7/8

22.23

66

29.9

—3—

3 3/16″
(80.9)
2 15/16″
(74.6)

1 7/16″
(36.5)

D SUCTION LINE
3/8″ LIQUID LINE
(9.5)

C
9 1/2″
(241.3)

10 13/16″
(274.6)

3/4″ NPT PLUGGED

(19.1)

DRAIN

7 1/4″
(184.2)

1 7/16″
(36.5)
11/16″

3/4″ NPT DRAIN
(19.1)

13/16″

(20.6)

1 3 /4 ″
(44.4)

3/16″

2 5/16″
(58.7)

(17.4)

(4.8)

19″
(482.6)

A

FRONT

RIGHT SIDE

UNCASED COILS CC5AXA018, 024, 030, 036, 042, CC5AXW024, 030, 036 CC5AXCO48

3 3/16″
(80.9)
1 7/16″
(36.5)

2 15/16″
(74.6)

D SUCTION LINE
C

9 1 /2 ″
(241.3)

3/8″ LIQUID LINE
(9.5)

10 13/16″
(274.6)

7 1 /4 ″
(184.2)

1 7/16″
(36.5)

1 3 /8 ″
(34.9)

11/16″

19″
(482.6)

(17.4)

13/16″

2 5/16″
(58.7)

3/4″ NPT DRAIN
(19.1)

(20.6)

A

LEFT SIDE

FRONT
UNCASED COILS CC5AXW042, 048, 060, CC5AXA060

A98068

A

C

D

SHIPPING WEIGHT

UNIT

SERIES

In.

mm

In.

mm

In.

mm

Lb.

Kg.

CC5AXA018014

A

12-5/8

320.7

10-9/16

268.3

5/8

15.88

15

6.8

CC5AXA024014

A

12-5/8

320.7

12-11/16

322.2

5/8

15.88

17

7.7

CC5AXW024017

A

15-15/16

404.8

14-3/4

374.6

3/4

19.05

22

10.0

CC5AXA030014

A

12-5/8

320.7

15-1/8

384.2

3/4

19.05

20

9.1

CC5AXW030017

A

15-15/16

404.8

14-3/4

374.6

3/4

19.05

22

10.0

CC5AXA036017

A

15-15/16

404.8

18-1/2

469.9

3/4

19.05

24

10.9

CC5AXW036021

A

19-3/8

492.1

17-3/4

450.8

3/4

19.05

26

11.8

CC5AXA042021

A

19-3/8

492.1

17-3/4

450.8

7/8

22.23

26

11.8

CC5AXW042024

A

22-15/16

582.6

16-3/16

411.1

7/8

22.23

28

12.7

CC5AXW048024

A

22-15/16

582.6

20-1/16

509.6

7/8

22.23

31

14.0

CC5AXC048021

A

19-3/8

492.1

20-1/16

509.6

7/8

22.23

27

12.2

CC5AXA060024

A

22-15/16

582.6

20-1/16

509.6

7/8

22.23

31

14.0

CC5AXW060031

A

29-15/16

760.4

20-1/16

509.6

7/8

22.23

39

17.7

—4—

COOLING CAPACITIES (MBtuh)
COIL REFRIGERANT TEMPERATURE* (°F)

UNIT
SIZE

A018

A024
W024

A030
W030

A036
W036

A042
W042

A048
W048

C048

A060

W060

EVAP
AIR
CFM
BF
450
0.17
600
0.22
750
0.25
600
0.12
800
0.16
1000
0.18
750
0.13
1000
0.17
1250
0.20
900
0.10
1200
0.13
1500
0.16
1050
0.14
1400
0.17
1750
0.20
1200
0.18
1600
0.22
2000
0.25
1200
0.11
1600
0.15
2000
0.19
1600
0.22
2000
0.25
2400
0.28
1600
0.16
2000
0.19
2400
0.21

35

40

45

50

55

Evaporator Air — Entering Wet Bulb Temperature (°F)
62
22
15
26
19
30
22
28
20
34
25
39
29
37
26
45
33
52
39
42
34
50
41
57
48
45
37
53
45
60
52
48
39
55
47
61
54
44
39
52
48
57
55
57
47
65
55
71
62
63
52
71
60
78
68

67
27
15
33
18
38
21
36
20
43
24
49
27
46
25
57
31
66
36
52
32
62
39
70
44
56
54
66
41
73
47
59
36
68
43
74
49
57
36
65
44
71
50
71
44
80
51
88
57
78
48
88
55
96
62

* Saturated suction leaving evaporator coil
CFM — Cubic Ft. per Minute
EWB — Entering Wet Bulb (°F)
LWB — Leaving Wet Bulb (°F)
TC — Total Cooling Capacity 1000 Btuh

72
34
14
41
17
47
20
44
18
52
22
60
25
57
24
70
29
81
34
63
30
75
35
84
40
68
32
79
37
87
42
71
33
80
38
88
42
69
33
78
38
85
42
87
41
97
46
105
50
94
44
105
50
114
54

62
18
14
22
17
25
20
24
18
29
22
33
26
31
24
38
29
44
35
35
30
43
38
49
44
38
33
45
41
51
47
41
36
47
43
53
50
36
35
43
42
49
49
48
43
54
50
60
56
54
47
61
55
67
62

67
24
13
29
16
33
19
31
17
37
21
43
25
41
23
50
28
57
23
46
29
55
35
62
41
49
31
58
38
65
44
52
34
60
40
66
45
48
33
56
40
62
46
62
40
70
46
77
52
69
44
78
51
85
57

72
30
13
37
15
42
17
39
16
47
20
54
23
52
22
63
26
73
30
57
27
68
32
76
37
61
29
72
34
80
38
64
30
74
35
81
39
62
30
71
35
78
40
78
37
88
42
95
46
85
40
96
46
104
51

62
14
12
18
15
20
17
19
16
23
19
27
23
25
21
30
26
35
30
28
27
34
33
39
39
31
29
36
36
42
42
33
32
39
38
44
44
30
30
37
37
42
42
38
37
43
43
48
48
43
41
49
48
55
54

67
20
12
24
14
28
17
26
15
32
19
36
22
34
20
42
25
48
29
39
26
46
32
52
37
41
28
49
34
55
40
44
30
51
36
57
42
40
29
46
36
50
41
52
36
59
42
65
47
59
40
66
46
73
52

72
26
11
32
13
37
15
34
14
41
17
47
20
45
19
55
23
63
27
50
24
60
29
67
33
54
26
63
31
70
35
57
28
66
32
72
36
53
27
61
32
68
36
68
33
76
38
83
42
75
36
85
42
93
46

62
11
10
14
12
17
14
15
13
19
16
22
19
19
17
25
21
29
25
22
22
28
28
33
33
25
25
31
31
36
36
30
30
33
33
38
38
25
25
31
31
36
36
31
31
36
36
41
41
35
35
41
41
46
46

67
16
10
19
12
22
14
21
13
25
16
29
19
27
17
33
22
38
25
31
22
37
28
42
33
33
24
39
30
44
35
36
27
41
32
46
37
29
25
35
31
39
37
41
31
46
37
51
41
47
35
53
41
58
46

72
22
9
27
11
30
13
29
12
35
15
39
17
38
16
46
20
53
23
42
21
50
25
57
29
45
23
53
27
60
31
49
24
56
29
62
33
43
23
50
28
55
32
57
29
64
33
70
37
64
32
72
37
79
41

62
9
8
12
10
14
11
13
11
16
13
19
16
14
14
17
17
20
20
19
19
23
23
27
27
20
20
25
25
30
30
22
22
27
27
32
32
20
20
25
25
29
29
26
26
30
30
34
34
29
29
34
34
39
39

67
11
8
13
10
15
12
15
11
18
14
20
16
16
14
19
18
22
21
22
19
26
23
30
28
23
21
26
28
32
30
26
23
30
28
34
32
21
21
25
25
29
29
29
26
33
31
36
34
34
29
39
34
43
39

BF — Bypass Factor
MBH — 1000 Btuh
SHC — Sensible Heat Capacities (1000 Btuh) shown in Italic type. SHC is based on 80°F db temperature of air entering the evaporator coil. Below 80°F db, subtract (corr factor x cfm) from SHC.
Above 80°F db, add (correction factor x cfm) to SHC.

See notes on page 6.

—5—

72
18
8
21
10
24
11
23
10
27
13
31
15
25
13
30
16
34
19
33
18
40
22
45
25
36
19
42
23
47
27
39
21
45
25
50
29
32
19
37
24
41
27
44
24
50
28
55
31
51
27
58
32
64
36

NOTES:
1. Formulas:
Leaving db = entering db —

sensible heat cap.
1.09 x CFM

Leaving wb = wb corresponding to enthalpy of air leaving coil (hLWB)
hLWB = hEWB —

total capacity (Btuh)
4.5 x CFM

where hEWB = enthalpy of air entering coil.
2. Direct interpolation is permissible. Do not extrapolate.
3. Fan motor heat has not been deducted.
4. All data points are based on 10°F superheat leaving coil, and use of thermal expansion valve device.
5. All units have sweat suction tube connection and a liquid tube connection. For 1-1/8-in. system suction tube, 3/4- x 1-1/8-in. suction tube connection adapter
is available as accessory.
6. Check-Flo-Rater pistons (sized for matched cooling-only systems). Refer to outdoor unit installation instructions for pistons required for other systems.
7. The CD5A and CC5A coils can be used in any properly designed system using R-22 or Puron® refrigerant.
8. Before using maximum cfm shown in table, check coil static pressure drop to ensure system blower can provide necessary static pressure needed for coil
and duct systems.

ENTERING AIR DRY BULB TEMPERATURE (°F)

BYPASS
FACTOR
0.10
0.20
0.30

79

78

81

82

0.98
0.87
0.76

1.96
1.74
1.53

77

76
75
83
84
84
Correction Factor
2.94
3.92
4.91
2.62
3.49
4.36
2.29
3.05
3.82

Under 75
Above 85

Use formula
shown below

Interpolation is permissible.
Correction Factor = 1.09 x (1 – BF) x (db – 80)

INDOOR COIL PISTONS
UNIT

FACTORY-INSTALLED INDOOR PISTON SIZE

CD5AXA018
CC5AXA018

52

CD5AXA024, W024
CC5AXA024, W024

59

CD5AXA030, W030
CC5AXA030, W030

67

CD5AXA036, W036
CC5AXA036, W036

70

CD5AXA042, W042
CC5AXA042, W042

78

CD5AXA048, C048, W048
CC5AXC048, W048

84

CD5AXA060
CC5AXA060

90

CD5AXW060
CC5AXW060

90

ACCESSORY EMPTY COIL CASING FOR UNCASED A-COIL
ACCESSORY PART NO.*

NOMINAL CC5A COIL SIZES

KCAKC1212ECC

A018, A024, A030

DIMENSIONS (In.) W x H x D
14-3/16 x 19 x 21

KCAKC1312ECC

W024, W030, A036

17-1/2 x 20-1/2 x 21

KCAKC1408ECC

W036, A042, C048

21 x 22 x 21

KCAKC1508ECC

W042, W048, A060

24-1/2 x 22 x 21

KCAKC1604ECC

W060

31-1/2 x 22 x 21

* Individual casings are sold and shipped in multi-packs as indicated in the 8th and 9th digits.

—6—

COIL STATIC PRESSURE DROP (IN. WC)
UNIT SIZE

BULB

AIR QUANTITY (CFM)

A018

WET
DRY

400
0.08
0.06

A024

WET
DRY

600
0.16
0.13

700
0.21
0.17

800
0.27
0.21

900
0.35
0.27

W024

WET
DRY

600
0.11
0.07

700
0.15
0.10

800
0.19
0.13

900
0.23
0.16

A030

WET
DRY

700
0.16
0.14

800
0.21
0.18

900
0.26
0.22

1000
0.32
0.28

W030

WET
DRY

700
0.12
0.09

800
0.16
0.12

900
0.19
0.15

1000
0.24
0.18

1100
0.28
0.22

A036

WET
DRY

900
0.16
0.14

1000
0.20
0.17

1100
0.24
0.21

1200
0.28
0.24

1300
0.33
0.28

W036

WET
DRY

900
0.13
0.11

1000
0.16
0.13

1100
0.19
0.16

1200
0.23
0.18

1300
0.27
0.21

A042

WET
DRY

1100
0.19
0.16

1200
0.22
0.18

1300
0.26
0.21

1400
0.30
0.25

W042

WET
DRY

1100
0.13
0.12

1200
0.15
0.13

1300
0.18
0.15

1400
0.21
0.16

A048

WET
DRY

1400
0.21
0.17

1500
0.24
0.19

1600
0.27
0.22

1700
0.31
0.25

W048

WET
DRY

1400
0.19
0.15

1500
0.22
0.17

1600
0.24
0.20

1700
0.27
0.22

1800
0.31
0.25

C048

WET
DRY

1300
0.22
0.17

1400
0.26
0.20

1500
0.30
0.23

1600
0.34
0.26

A060

WET
DRY

1600
0.24
0.20

1700
0.27
0.22

1800
0.31
0.25

1900
0.34
0.27

W060

WET
DRY

1600
0.17
0.11

1700
0.19
0.13

1800
0.21
0.14

1900
0.23
0.16

—7—

500
0.12
0.09

600
0.16
0.13

700
0.22
0.18

2000
0.25
0.17

1500
0.24
0.18

2100
0.27
0.18

2200
0.30
0.21

SERVICE TRAINING
Packaged Service Training programs are an excellent way to increase your
knowledge of the equipment discussed in this manual, including:
• Unit Familiarization
• Maintenance
• Installation Overview
• Operating Sequence
A large selection of product, theory, and skills programs is available, using popular
video-based formats and materials. All include video and/or slides, plus companion
book.
Classroom Service Training plus "hands-on" the products in our labs can mean
increased confidence that really pays dividends in faster troubleshooting, fewer
callbacks. Course descriptions and schedules are in our catalog.
CALL FOR FREE CATALOG 1-800-962-9212
[ ] Packaged Service Training

[ ] Classroom Service Training
A94328

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels: PDS CC5A.18.5
© 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St.

Indpls., IN 46231

—8—

PRINTED IN U.S.A.

Catalog No. 12CC-5A1

3-99



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Create Date                     : 1999:04:01 11:51:45Z
Modify Date                     : 2005:11:14 11:52:03-05:00
Metadata Date                   : 2005:11:14 11:52:03-05:00
Producer                        : Acrobat Distiller 2.0 for Windows
Keywords                        : 
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : Carrier Corporation
Subject                         : 
Document ID                     : uuid:1ebb0386-01f4-4db5-ac61-cd255260eb53
Instance ID                     : uuid:aa988d25-c946-480e-8cf1-429252aef945
Page Count                      : 8
Author                          : Carrier Corporation
EXIF Metadata provided by EXIF.tools

Navigation menu