HUM
Humidifiers
Product Data
Controlling indoor humidity is very important. In many cases the
air inside a home is drier than a desert. Dry, indoor air is often the
culprit for such common problems as itchy or cracked skin, eye
irritation, dry nasal passages, and damaged home furnishings. Dry
indoor air can also increase the possibility of catching cold and flu
viruses and can reduce the efficiency and effectiveness of the
heating system.
All of these problems can be alleviated with the help of a Bryantr
humidifier. Bryant offers four humidifier models designed to put
moisture back into the indoor environment so homeowners can
relax in warm, soothing comfort. Depending on the model that best
matches the system, a Bryant humidifier can deliver between 12
and 18 gallons (45 and 68 liters) of moisture per day to minimize
the problems of excessively dry air. And, because humidified air
feels warmer, using lower thermostat settings may be possible for
added energy savings.
Water Saver Models -- WBP Series units deliver 100% of water
used. For use in applications where water costs are high, with
septic systems or in drought--stricken areas
Large Fan Powered
Model
HUMBBLFP1418
Large Bypass
Models
HUMBBLBP2417
HUMBBWBP2417 (water saver)
FEATURES/BENEFITS
Easy Access for Cleaning and Maintenance—The treated
aluminum water panel (or wicking paper water panel in the
water--saver model) ensures top performance. Front or side access
door allows for quick and convenient removal and replacement of
water panel.
Smooth, Low--Noise Operation—Nearly silent operation is the
result of Bryant humidifier’s precision--engineered fan and motor
combination on fan powered models. Air is drawn through the
water panel quietly and efficiently, turning water into the water
vapor that humidifies the home.
Long Lasting, Attractive Cover—The outside casing and interior
components of all Bryant humidifiers are made from durable UV
resistant plastic. This plastic resists deterioration, even when
exposed to ultra--violet light sources common in many systems.
Built--In Bypass Damper—On the LBP, SBP and WBP models.
Optimum Distribution of Moisture—Through the combination
of the solenoid valve and water distribution system by Bryant,
homeowners will benefit from the most optimum distribution of
moisture possible.
Four Humidity Control Options—Choose between four separate
control options, the Humidistat, the HumidiTract, the
Thermidistatt, and the Evolutiont Control. Each of these units
provide precise control over the humidity levels in the home.
Taupe Metallic—Color--matched to the furnace (excluding small
fan powered models).
Small Bypass
Model
HUMBBSBP2412
Small Fan Powered
Model
HUMBBSFP1016
TM
MODEL NUMBER NOMENCLATURE
HUM
BB
LFP
14
18
Product Type
Brand
Model Type
Series
Gallons (Liters) Per Day
Humidifier
Bryant
LFP --- Large Fan Powered
SBP --- Small Bypass
LBP --- Large Bypass
SFP --- Small Fan Powered
WBP --- Water Saving
Large Bypass
14 --- LFP
24 --- SBP, LBP, WBP
10 --- SFP
LFP --- 18 (68)
SBP --- 12 (45)
LBP --- 17 (64)
SFP --- 12.8 (48)
WBP --- 17 (64)
HUM
PHYSICAL DATA
MODEL
Gallons
(Liters)/Day
Gallons (Liters)/Hr
Type
Airflow
HUMBBLFP1418
HUMBBLBP2417
18 (68)
HUMBBWBP2417
17 (64)
HUMBBSBP2412
HUMBBSFP1016
12 (45)
12.8 (48)
6 (23)
3 (11)
3.2 (12)
Fan
Bypass
Sump with Overflow
Drain
Fan
Water Flow
Drain Through
Drain Through
General
Water Panel
P110--- 3545
P110--- 3545
P110--- 4545
P110--- 1045
324897--- 761
Replacement
(10 packs)
(10 packs)
(5 --- 2 packs)
(10 packs)
(10 packs)
Water Panel
13 x 10 x 1.7
9.9 x 9.6 x 1.7
9.7 x 9.2 x 1.2
in (mm)
(330 x 254 x43)
(251 x 244 x 41)
(248 x 235 x 32)
(H x W x D)
Water Panel
Quick Release Cover
Side Door
Access
Unit Size
18.0 x 16.0 x 10.25
15.125 x 14.0 x 10.25
12.25 x 14.0 x 10.25
12 x 12.5 x 10.18
in (mm)
(457 x 406 x 260)
(384 x 356 x 260)
(311 x 356 x 260)
(305 x 318 x 259)
(H x W x D)
Weight lbs (kg)
17.1 (7.8)
8.0 (4)
7.0 (3)
10.9 (5)
Water Usage
6 (23)
3 (11)
3.2 (12)
Gal (liters)/hr)
Electrical Control Low---Voltage Solenoid
Volts
24V--- 60Hz
Amps (Max)
0.5
VA (Max)
12
Watts
2.3
1.0
High Voltage Cord
Volts
120V--- 1ph--- 60Hz
N/A
115V--- 1ph--- 60Hz
Amps
0.7
N/A
1.9
Connections
Water Inlet
1/4--- in. Copper Tubing
Water Drain
1/2--- in. I.D. plastic hose
5/8--- in. Tube
Bypass Opening
N/A
6--- in. round elbow or straight
N/A
Duct Opening
14.81 x 14.25
9.87 x 12.62
9.5 x 9.5
11.87 x 11.5
in (mm)
(376 x 362)
(251 x 321)
(241 x 241)
(302 x 292)
(W x H)
Standard Equipment
Water Valve
Solenoid, 24VAC
Thermal Protected
Thermal Protected
120VAC
Motor
N/A
115VAC, 25MH
(0.014HP = 1/70 HP)
Relay
DPST 24VAC*
N/A
SPST 24VDC to AC
Humidistat
24V
24V (not included)
24V
Saddle Valve
Standard
Damper
N/A
Standard
N/A
Template
Installation Sheet Included
Accessories
HumidiTract
KUAW0101CAC
Automatic Control
Current Sensing
P110--- 0050
N/A
Relay
*
Field---supplied part no. HN61KQ120
2
DIMENSIONS
Model HUMBBLBP2417 & HUMBBWBP2417
Model HUMBBLFP1418
10.25
(260)
14.0
(356)
10.25
(260)
16.0
(406)
Damper
"Season"
Selector
SUMMER
WINTER
15.75
(400)
5.68
(144)
Model HUMBBSBP2412
Model HUMBBSFP1016
14.0
(356)
10.25
(260)
DUCT CUT-OUT SIZE
WxH
9.88 x 12.75
(251 x 324)
HUM
DUCT CUT-OUT SIZE
WxH
14.81 x 14.25
(376 x 362)
SUMMER
Built-In
Bypass
Damper
18.0
(457)
OPTIONAL WATER
VALVE MOUNTING
WATER
INLET
SIDE
DOOR
Damper
"Season"
Selector
WINTER
SUMMER
13.0
(330)
12
(305)
SUMMER
Built-In
Bypass
Damper
DRAIN
5.68
(144)
12.5
(318)
115V PLUG CORD
DUCT CUT-OUT SIZE
WxH
9.50 x 9.50
(241 x 241)
24VAC
10.18
(259)
FRONT ACCESS COVER
A08384
3
RECOMMENDED RELATIVE HUMIDITY BY OUTDOOR TEMPERATURE
OUTDOOR TEMP
_F (_C)
OUTDOOR RELATIVE HUMIDITY
(%)
INDOOR RELATIVE HUMIDITY
(%) W/O HUMIDIFIER*
MAX RECOMMENDED INDOOR
RELATIVE HUMIDITY{
--- 10 (--- 23)
30 to 70
1 to 2
20 (Lo)
0 (--- 18)
30 to 70
2 to 4
25
10 (--- 12)
30 to 70
3 to 6
30
20 (--- 7)
30 to 70
4 to 10
35
30 (--- 1)
30 to 70
6 to 15
40 (Med)
*
Indoor relative humidity level when outdoor air is heated to 72_F/22_C.
{ As stipulated by the Air Conditioning Contractors of America.
INDOOR RELATIVE HUMIDITY LIMIT FOR NO WINDOW CONDENSATION
HUM
(Indoor Air at 74_F/23_C Dry Bulb)
OUTDOOR TEMPERATURE
_F (_C)
SINGLE PANE WINDOWS (%)
DOUBLE PANE WINDOWS (%)
40 (4)
39
59
30 (--- 1)
29
50
20 (--- 7)
21
43
10 (--- 12)
15
36
0 (--- 18)
10
30
--- 10 (--- 23)
7
26
--- 20 (--- 29)
5
21
--- 30 (--- 34)
3
17
MAXIMUM MOISTURE REQUIREMENTS*
VOLUME OF RESIDENCE
CUBIC FEET
(CUBIC METER)
TIGHT HOUSE
AVERAGE HOUSE
POUNDS
(KILOGRAMS) PER
HOUR
GALLONS (LITERS)
PER DAY
POUNDS
(KILOGRAMS) PER
HOUR
GALLONS (LITERS)
PER DAY
8,000 (227)
1.76 (0.8)
5.09 (19)
3.52 (1.6)
10.17 (38)
10,000 (283)
2.21 (1.0)
6.35 (24)
4.41 (2.0)
12.72 (48)
12,000 (340)
2.64 (1.2)
7.63 (29)
5.29 (2.4)
15.26 (58)
14,000 (396)
3.09 (1.4)
8.91 (34)
5.92 (2.7)
17.08 (65)
16,000 (453)
3.53 (1.6)
10.18 (39)
7.06 (3.2)
20.35 (77)
18,000 (510)
3.97 (1.8)
11.45 (43)
7.94 (3.6)
22.89 (87)
20,000 (566)
4.41 (2.0)
12.72 (48)
8.82 (4.0)
25.44 (96)
22,000 (623)
4.85 (2.2)
13.99 (53)
9.71 (4.4)
27.98 (106)
24,000 (680)
5.29 (2.4)
15.27 (58)
10.59 (4.8)
30.52 (116)
26,000 (736)
5.74 (2.6)
16.54 (63)
11.47 (5.2)
33.07 (125)
28,000 (793)
6.18 (2.8)
17.81 (67)
12.35 (5.6)
35.61 (135)
30,000 (850)
6.62 (3.0)
19.08 (72)
13.24 (6.0)
38.16 (144)
*
Based on design conditions of outdoor 20_F/ ---7_C dry bulb, 80% RH; indoor 70_F/21_C dry bulb, 40% RH, and minimum moisture production from residential operations for an absolute humidity difference of 0.0049 lb/hr.
NOTE:
Tight house is defined as being well insulated, having vapor barriers, tight storm doors and windows with weatherstripping, and having dampered fireplaces.
Average house is defined as being insulated, having vapor barriers, loose storm door and windows and having dampered fireplace.
4
TYPICAL HUMIDIFIER INSTALLATIONS
HORIZONTAL
Built-in Bypass Damper
HUM
Built-in Bypass Damper
Built-in Bypass Damper
DOWNFLOW
UPFLOW
*
*Note - It is recommended
that hot water be supplied
in this return air application.
UPFLOW
UPFLOW
A06225
5
HUMIDIFIER REPLACEMENT WATER PANELS
DESCRIPTION
USED WITH
TOTALINE ORDERING NO.
HUMBBLFP1418
P110--- 3545
HUMBBLBP2417
Replacement Water Panel
HUMBBSBP2412
P110--- 1045
HUMBBSFP1016
324897--- 761
HUMBBWBP2417
P110--- 4545 (2 pack)
USED WITH
PART NO.
HUM
HUMIDIFIER ACCESSORIES
DESCRIPTION
HUMBBLFP1418
HumidiTract Automatic Control
HUMBBLBP2417
KUAWC0101CAC --- A10
HUMBBSBP2412
HUMBBWBP2417
Humidistat Manual Control
HUMBBWBP2417
4363 (Totaline)
Relay
HUMBBLFP2417
HN61KQ120 (Totaline)
E2008 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 08/08
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
6
Catalog No. PDSHUM---6
Replaces: PDSHUM.5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:09:05 14:45:05-04:00 Create Date : 2008:09:05 14:45:05-04:00 Format : application/pdf Title : PDSHUM-6 Creator : bact625 Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:cfcacec0-7f4d-42b0-a412-9359950b5681 Instance ID : uuid:71021d2a-70d0-4a61-84e0-b08e8fb6bf26 Page Count : 6 Author : bact625EXIF Metadata provided by EXIF.tools