353AAV Plus 90x 4--Way Multipoise Condensing Gas Furnace Input Rates: 40,000 Only Product Data 4--WAY MULTIPOISE DESIGN ALLOWS MORE APPLICATIONS the furnace resulting in lower electrical usage. The high efficiency achieved by superior heat transfer is made only better—by optimizing the efficient ECM motor speed tap locations. A standard media filter cabinet accessory is provided with the Plus 90x in order to provide an opportunity to enhance indoor air quality. As with all other Bryant furnaces, this model is designed to work as a part of the total home comfort system which includes elements for cooling, air cleaning, humidification, ventilation and zoning. Boosting the unit’s efficiency with the ECM motor and Bryant’s deluxe features show the Plus 90x has been designed with the homeowner in mind. PLUS 90X FEATURES & BENEFITS EverlasticTM — Exclusive Everlastic coating, a patented polypropylene laminate is used on the secondary heat exchanger and greatly reduces maintenance. Perfect Light™ Igniter — Bryant’s unique Perfect Light™ igniter is not only physically robust but it is also electrically robust. It is capable of running at line voltage and does not require complex voltage regulators as do other brands. This unique feature further enhances the reliability of the Plus 90x gas furnace and continues Bryant’s tradition of technology leadership and innovation in providing a reliable and durable product. A05085 A UNIQUE SEER SOLUTION The Plus 90x is an exciting addition to your product line. This high--efficiency 4--way multipoise design furnace allows more applications while the ECM motor and Bryant’s control logic combine to provide a SEER increase of up to 1.5 points.* Some of Bryant’s best--engineered components contribute to the efficient performance of this condensing furnace. The Plus 90x utilizes Power Lightt hot surface ignition (HSI), which ignites the burners directly. HSI eliminates gas waste that typical continuous--pilot designs can bring. Hot surface ignition has proven to contribute to reliable start--up and operation of Bryant furnaces. Another deluxe feature included with this furnace is Bryant’s trusted Everlastict secondary heat exchanger; a patented polypropylene laminate that provides exceptional heat transfer and corrosion resistance. Using the exclusive flow--through design, the secondary heat exchanger reduces the pressure drop in FanOn™ — Improves comfort all year long by allowing the homeowner to select different fan speeds during continuous fan operation to achieve more or less airflow. This is done right at the thermostat. SmartEvap™ — This feature allows your system to reduce summertime humidity levels by nearly 10% over standard systems. Media Filter Cabinet — Enhanced indoor air quality in your home is made easier with our media filter cabinet—a standard accessory on all Deluxe furnaces. When installed as a part of your system, this cabinet allows for easy and convenient addition of a Bryant high--efficiency air filter. Control Center — Microprocessor controls sequencing and furnace operation. Equipped with a component test feature and status indicator light to assist in troubleshooting. Microprocessor controls blower times to start blower after main burners ignite to eliminate cold air blowing into rooms. *as compared to the Air---Conditioning, Heating and Refrigeration Institute’s standard coil---only rating (A/Cs up to 3.5 tons) when paired with selected Bryant evaporator coils. 1 Casing — One piece, seamless wrap--around construction of heavy, galvanized steel that resists corrosion. Direct or Non--direct Venting — The Plus 90x can be installed as a 1 pipe/Non--Direct vent (except 140 size unit and in manufactured/mobile home installations) or 2 pipe/Direct vent furnace. All direct vent Plus 90x models can be installed in a manufactured (mobile) home when the optional kit is used. This provides added flexibility to meet diverse installation needs. Adjustable Blower Speed — For precise airflow selection of heating or cooling operation. Monoport Burners — The burners are finely tuned for smooth, quiet combustion plus economical gas usage. Insulated Blower Compartment —The acoustical insulation reduces air and motor noise to promote quiet operation. Slow Opening Redundant Gas Valve — Shuts off gas to burners if any of the valves fails to close completely for any reason. The slow opening feature reduces start--up noise from rapid ignition. Combustion Products Venting — The combustion--air and vent pipes can terminate through a side wall or through the roof when used with a factory--authorized vent termination kit. Quality Registration — The Plus 90x is engineered and manufactured under an ISO 9001 registered quality system. 353AAV Insulation — Foil--faced insulation in heat exchanger section of the casing minimizes heat loss. Certifications — The Plus 90x Model units are CSA (A.G.A. and C.G.A.) design certified for use with natural and propane gases. The furnace is factory--shipped for use with natural gas. A CSA (A.G.A./C.G.A.) listed gas conversion kit is required to convert furnace for use with propane gas. The efficiency is GAMA efficiency rating certified. The Plus 90x meets California Air Quality Management District emission requirements. Refer to Vent Table, for elevation limitations. Bottom Closure — Factory--installed for side return; easily removable for bottom return. Filter — Cleanable filter with retainer is standard. Blower Access Panel Switch — Shuts off all 115--v power through furnace components whenever blower access panel is opened. BLOWER OFF-DELAY BLOWER OFF-DELAY 120 180 90 150 T1 DHUM TWINNING AND/OR COMPONENT TEST TERMINAL G COM 24V 24-V THERMOSTAT TERMINALS W HUMIDIFIER TERMINAL (24-VAC 0.5 AMP. MAX ) PLT TIT2 TEST / TWIN R HUH 3-AMP FUSE SEC-1 COM 24VAC PL1 LED OPERATION & DIAGNOSTIC LIGHT SEC-2 24V COM TRANSFORMER 24-VAC CONNECTION HEAT COOL MTR S 1 FAN TAPS BLOWER SPEED SELECTION TERMINALS SPARE 2 SPARE 1 PL1-LOW VOLTAGE MAIN HARNESS CONNECTOR EAC-2 EAC-1 115-VAC (L2) NEUTRAL CONNECTIONS L1 BL-1 PR-1 PL2 EAC-1 TERMINAL (115-VAC 1.0 AMP. MAX0 115-VAC (LI) NUETRAL CONNECTIONS PL1-HOT SURFACE IGNITER & INDUCER MOTOR CONNECTION A08345 A92505 2 A02172 1 2 3 13 4 14 5 6 6 7 8 9 10 15 16 11 12 353AAV 17 18 19 20 A08421 1. Burner sight glass for viewing burner flame. 11. Heavy--duty blower circulates air across the heat exchangers to transfer heat into the home. 2. Burner assembly (inside), operates with energy--sav- ing, inshot burners and hot surface igniter for safe, dependable heating. 12. Air filter and retainer may be used for side or bottom 3. Combustion--air intake connection to ensure contam- 13. Rollout switch (manual reset) to prevent overtemper- 4. Redundant gas valve, safe, efficient, features 1 gas 14. Primary serpentine heat exchanger (inside). Stretches return application. inant--free air (right or left side). ature in burner area. control with 2 internal shutoff valves. fuel dollars with the S--shaped heat--flow design. Solid weld--free construction of corrosion--resistant aluminized steel means reliability. 5. Junction box for 115--v electrical power supply. (right or left side) 15. A 3--amp fuse provides electrical and component protection. 6. Vent outlet uses sealed PVC pipe to carry vent gases from the furnace’s combustion system (right or left side). 16. Light emitting diode (LED) on control center. Code lights are for diagnosing furnace operation and service requirements. 7. Secondary condensing heat exchanger (inside), wrings out more heat through condensation of gases. Constructed with polypropylene--laminated steel to ensure durability. 17. Control center. 18. Blower access panel safety interlock switch. 8. Pressure switch ensures adequate flow of flue products through furnace and out vent system. 19. Transformer (24v) behind control center provides low--voltage power to furnace control center and thermostat. 9. Inducer motor pulls hot flue gases through the heat exchangers, maintaining negative pressure for added safety. 20. Power choke (used with 1 HP and 3/4 HP motors.) 10. Condensate drain connection collects moisture condensed during the combustion process. 1 2 3 4 5 6 3 PHYSICAL DATA UNIT SIZE SHIPPING WEIGHT LB. (KG) LIMIT CONTROL HEATING BLOWER CONTROL (Off Delay) BURNERS (Monoport) GAS CONNECTION SIZE GAS VALVE(Redundant) Manufacturer Minimum Inlet Pressure (in. wc) Maximum Inlet Pressure (in. wc) IGNITION DEVICE DIRECT--- DRIVE MOTOR (ECM X--- 13) MOTOR FULL LOAD AMPS RPM (Nominal) --- SPEEDS BLOWER WHEEL DIAMETER X WIDTH --- IN (mm) FILTER SIZE (Washable) --IN (mm) DE C ER 036040 175 (47) 036060 182 (57) 036080 198 (64) 048080 205 (69) SPST TIFIE 060100 232 060120 261 (74) 5 6 1 1 10.9 10.9 11 X 10 (279 X 254) (1) 20 X 25 X 3/4 (508 X 635 X 19) 11 X 10 (279 X 254) (1) 24 X 25 X 3/4 (610 X 635 X 19) Solid---State Time Operation 2 3 4 4 1/2---in. NPT White---Rodgers 4.5 (Natural Gas) 13.6 (Natural Gas) Hot Surface 1/2 1/2 1/2 6.8 6.8 6.8 10 X 7 (254 X 178) 3/4 8.4 1050---5 10 X 7 10 X 7 11 X 8 (254 X 178) (254 X 178) (279 X 203) (1) 16 X 25 X 3/4 (406 X 635 X 19) Always Ask For S I GN D 353AAV **Note: 060--120 Sizes are phasing out.** CERTIFIED Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org. 4 BRYANT ACCESSORIES* ACCESSORIES THERMOSTAT --NON--- PROGRAMMABLE THERMOSTAT --PROGRAMMABLE ZONING CONTROL KGANP4601ALL KGANP3901ALL KGAMH0301KIT KGASB0301ALL 2 --- IN. --- KGAVT0101BRA 3 --- IN. --- KGAVT0201BRA 2 --- IN. --- KGAVT0701CVT 3 --- IN. --- KGAVT0801CVT KGAHT01010CFP P908 --- 0001 Model EACB Models GAPAAXBB1625, GAPAAXBB2025 Models EZXCAB, FILCAB Model HUM Model HRV Model ERV Model UVL KGAET0106ETK KGBAC0110DGK KGAWF1301UFR KGAWF1401UFR KGAWF1501UFR For use with 1 --- speed Air Conditioner --- deg. F/C, Auto Changeover --- T6 --- NAC, T2 --- NAC For use with 1 --- speed Air Conditioner --- deg. F/C, Auto Changeover --- T6 --- NHP--- T2 --- NHP* For use with 2 --- speed Air Conditioner --- deg. F/C, Auto Changeover --- T6 --- NRH* For use with multi--- use / stage configurations --- deg. F/C, Auto Changeover/Temperature and Humidity Control --- T6 --- PRH{ For use with 1 --- speed Air Conditioner --- deg. F/C, Auto Changeover, 7 --- Day Programmable --T6 --- PAC For use with 1 --- speed Air Conditioner --- deg. F/C, Auto Changeover, 7 --- Day Programmable --T6 --- PHP* For use with 2 --- speed Air Conditioner --- deg. F/C, Auto Changeover, 7 --- Day Programmable --T6 --- PRH* For use with 1 --- speed Air Conditioner --- deg. F/C, 5 --- 2 Day Programmable --- T2 --- PAC For use with multi--- stage applications --- deg. F/C, Auto Changeover, 7 --- Day Programmable --T6 --- PHP} For multi--- use / stage configurations --- deg. F/C, Auto Changeover, 7 --- Day Programmable/ Temperature and Humidity Control --- T6 --- PRH{ Comfort Series Three--- Zone Zone Kit --- ZONEBB3ZAC01, ZONEBB3ZHP01 2 --- Performance Series Zoning/Temperature and Humidity Control --- ZONEBB2KIT01 --- B 4 --- Performance Series Zoning/Temperature and Humidity Control --- ZONEBB4KIT01 --- B 8 --- Performance Series Zoning/Temperature and Humidity Control --- ZONEBB8KIT01 --- B *Factory---authorized and field---installed. Gas conversion kits are CSA (A.G.A./C.G.A.) recognized Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant cased coil is used. *Model HP and 2S thermostat must be field converted to air conditioner operation. {Thermidistatt Control control can be configured for multiple use and staging. It must be configured for each specific application. }Dual Fuel thermostat is used with furnace and heat pump application. 5 353AAV GAS CONVERSION KIT --NATURAL TO PROPANE GAS CONVERSION KIT --PROPANE TO NATURAL MANUFACTURED (MOBILE) HOME KIT DOWNFLOW BASE (For Combustible Floors)} VENT TERMINATION KIT (Bracket Only for 2 Pipes) CONCENTRIC TERMINATION KIT (Single Exit) CONDENSATE FREEZE PROTECTION KIT CONDENSATE NEUTRALIZER KIT (Obtained thru RCD) ELECTRONIC AIR CLEANER (EAC) AIR PURIFIER MECHANICAL AIR CLEANER HUMIDIFIER HEAT RECOVERY VENTILATOR ENERGY RECOVERY VENTILATOR UV LIGHTS VENT/EXHAUST PIPE EXTERNAL TRAP KIT DOOR GASKET KIT UNFRAMED FILTER, PERMANENT WASHABLE 3/4” (19mm) 16 x 25 (406 x 635 mm) UNFRAMED FILTER, PERMANENT WASHABLE 3/4” (19mm) 16 x 25 (508 x 635 mm) UNFRAMED FILTER, PERMANENT WASHABLE 3/4” (19mm) 16 x 25 (610 x 635 mm) A93086 353AAV CONCENTRIC VENT (DIRECT VENT/ 2-PIPE ONLY) A88202 A96214 DOWNFLOW SUBBASE A concentric vent kit allows vent and combustion-air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe. BRYANT CASED N-COIL One base fits all furnace sizes. The base is designed to be installed between the furnace and a combustible floor when no coil box is used or when a coil box other than a Bryant cased coil is used. It is CSA (A.G.A./C.G.A.) design certified for use with select Bryant furnaces when installed in downflow applications. (as shown) The Bryant Cased N-Coil or A-Coil is an upflow/downflow furnace coil which can also replace the downflow subbase when installing select Bryant furnaces on combustible flooring in the downflow orientation. A08450 A97432 CONTROLS: THERMOSTATS AND ZONING Available in programmable and non-programmable models, Bryant thermostats maintain a constant, comfortable temperature level in the home. For the ultimate in home comfort, Bryant’s 2, 4, and 8-zone systems allow temperature control of individual “zones” of the home. This is accomplished through a series of electronic dampers and remote room sensors. The 4-zone system is shown. C04009 MECHANICAL OR ELECTRONIC AIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. A01484 HUMIDIFIER By adding moisture to winter-dry air, a Bryant humidifier can often improve comfort and keep furniture, rugs, and draperies in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures. ENERGY/HEAT RECOVERY VENTILATOR Bryant’s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level. Especially useful for today’s tighter constructed houses. Energy recovery ventilator is shown. A08153 6 A08321 7 11⁄4" (32mm) 1" (25mm) 14 1⁄2" TYP (368mm) 26 15⁄16" TYP (684mm) 23 1⁄4" TYP (591mm) SIDE INLET SIDE INLET DIA THERMOSTAT ENTRY (13mm) 22 11 ⁄16" (576mm) 1⁄2-IN. 2-IN. VENT CONN (51mm) DIA GAS CONN (13mm) 1⁄2-IN. 26 15⁄16" (684mm) 26 1⁄4" (667mm) 1⁄2" 24 (666mm) 22 5⁄16" (567mm) 2-IN. COMBUSTIONAIR CONN (51mm) 13⁄16" (17mm) 11 ⁄16" E INLET OUTLET D (17mm) 11 ⁄16" TYP (14mm) DIMPLE LOCATORS FOR HORIZONTAL HANGING CONDENSATE DRAIN LOCATION (UPFLOW) 18 1⁄4" (464mm) 30 (775mm) 1⁄2" CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL RIGHT) OR ALTERNATE 1⁄2 -IN. DIA GAS CONN (21mm) 13⁄16" 9⁄16" UNIT SIZE 040-12 / 036040 060-12 / 036060 080-12 / 036080 080-16 / 048080 100-20 / 060100 120-20 / 060120 A 17-1/2 (445) 17-1/2 (445) 17-1/2 (445) 17-1/2 (445) 21 (25.4) 24-1/2 (622) D 15-7/8 (403) 15-7/8 (403) 15-7/8 (403) 15-7/8 (403) 19-3/8 (492) 22-7/8 (581) 353AAV E 16 (406) 16 (406) 16 (406) 16 (406) 19-1/2 (495) 23 (584) NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer‘s recommendation for equivalent diameters. 2. Minimum return-air opening at furnace: a. For 800 CFM 16-in . (406mm) round or 14 1 / 2 (368mm) x 12-in. (305mm) rectangle. b. For 1200 CFM 20-in . (508mm) round or 14 1 / 2 (368mm) x 19 1 / 2-in. (495mm) rectangle. c. For 1600 CFM 22-in .(559mm) round or 14 1 / 2 (368mm) x 23 1 / 4-in.(591mm) rectangle. d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM at 0.5 in. W.C. ESP. CONDENSATE DRAIN LOCATION (UPFLOW) (21mm) 33 1⁄4" TYP (845mm) 30 (783mm) 11 ⁄16" 29 DIA (22mm) TYP ACCESSORY (754mm) POWER ENTRY 32 5⁄8" 27 5⁄8" TYP (702mm) CONDENSATE (829mm) DRAIN TRAP 27 9⁄16" LOCATION TYP (700mm) (ALTERNATE UPFLOW) 24 1⁄2" (622mm) 17 5⁄16" 9 7⁄16" (440mm) TYP (240mm) 7⁄8-IN. DIA (22mm) POWER CONN 7⁄8-IN. CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL LEFT) 13⁄16" A AIRFLOW 22 1⁄4" TYP (565mm) 24 3⁄16" BOTTOM INLET (614mm) SIDE INLET 22 11 ⁄16" 2-IN. VENT CONN DIA THERMOSTAT ENTRY 1⁄2-IN. DIA POWER CONN 7⁄8-IN. DIA GAS CONN 1⁄2-IN. 2-IN. COMBUSTIONAIR CONN OUTLET 19" (483mm) 22 5⁄16" (567mm) 26 1⁄4" (667mm) 26 15⁄16" (694mm) 28 1⁄2" (724mm) (16mm) 11 ⁄16" (17mm) 7⁄16" (11mm) 1" (25mm) 39 7⁄8" (1013mm) 5⁄16" (8mm) 5⁄8" 13⁄16" (21mm) DOWNFLOW SUBBASE DIMENSIONS -- IN. (MM) PLENUM OPENING FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION 17-1/2 (445) 21 (533) 24-1/2 (622) Furnace with or without Cased Coil Assembly or Coil Box Furnace with or without Cased Coil Assembly or Coil Box Furnace with or without Cased Coil Assembly or Coil Box HOLE NO. FOR WIDTH ADJUST--MENT FLOOR OPENING A B C D 15---1/8 (384) 18---5/8 (473) 22-1/8 (562) 19 (483) 19 (483) 16-3/4 (425) 20---1/4 (514) 23-3/4 (603) 20---3/8 (518) 20---3/8 (518) 20---3/8 (518) 19 (483) 3 2 1 *The plenum should be constructed 1/4---in. (6 mm) smaller in width and depth than the plenum dimensions shown above. LOCATING TAB 1 1/4″ (32 μμ) TYP 353AAV PLENUM OPENING B A D 1 2 4 3 LOCATING TAB C FACTORY-SUPPLIED FIELD-INSTALLED INSULATION 4 3 2 1 COMBUSTION--AIR PIPE FOR NON--DIRECT VENT (1--PIPE) APPLICATION (SIZES 040 THROUGH 120 ONLY) FIELD-SUPPLIED 2-IN. (51 mm) DIA. PVC 90° ELBOW FIELD-SUPPLIED 2-IN. (51 mm) DIA. PVC PIPE LENGTH OF STRAIGHT PIPE PORTION OF COMBUSTION AIR INLET PIPE ASSEMBLY - IN. (mm) CASING WIDTH A A 17-1/2 (445 mm) 8-1/2 ± 1/2 (216 ± 13 mm) 21 (533 mm) 10-1/2 ± 1/2 (267 ± 13 mm) 24-1/2 (622 mm) COMBUSTION-AIR DISC (FACTORY-SUPPLIED IN LOOSE PARTS BAG) 12 ± 1/2 (305 ± 13 mm) A96211 CONCENTRIC VENT FOR DIRECT VENT (2--PIPE) APPLICATION (ALL MODEL SIZES) B IN. (MM) DIA PVC VENT/EXHAUST F E C IN. (MM) DIA 13/16 (30 mm) 11/2 D (38 mm) A B IN. (MM) DIA PVC INTAKE/COMBUSTION AIR KIT PART NO. KGAVT0701CVT KGAVT0801CVT A* 33---3/8 (848) 38---7/8 (987) B 2 (51) 3 (76) C 3---1/2 (89) 4---1/2 (114) D{ 16---5/8 (422) 21---1/8 (537) E 6---1/4 (159) 7---3/8 (187) F 5---3/4 (146) 6---1/2 (165) *Dimension A will change accordingly as Dimension D is lengthened or shortened. {Dimension D may be lengthened to 60---in. (1524 mm) maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12--- in. (305 mm) minimum. 8 353AAV CONDENSATE TRAP A93026 MEDIA FILTER CABINET 25 5/8" (651 mm) 23 5/8" (600 mm) 24 3/8" (619 mm) Opening with Flanges Bent 23 3/8" (594 mm) 23 1/8" (587 mm) Opening B Opening A Duct Side Furnace Side 23 3/4" (603 mm) Centerline Screw Slots 5 3/4 (146 mm) Media Filter Cabinet A B Shipped with sizes 16" (406) 17" (432) 16" (406) 040-08, 040-12, 060-08, 060-12, 060-16, 080-12, 080-16 20" (508) 21" (533) 20" (508) 080-20, 100-16, 100-20 24" (610) 25" (635) 24" (610) 120-20, 140-20 A05186 9 353AAV CLEARANCE TO COMBUSTIBLES 335122-201 REV. B LIT TOP A08435 10 UNIT SIZE CAPACITY* Direct Vent (2---pipe) (Shaded capacities are specified on the rating plate) CAPACITY* Non---Direct vent (1---pipe) AFUE* Direct Vent (2---pipe) Non---weatherized ICS AFUE* Non---Direct Vent (1---pipe) Non-weatherized ICS Upflow Downflow Horizontal Upflow Downflow Horizontal Upflow Downflow Horizontal Upflow Downflow Horizontal Input Btuh { UNIT SIZE CERTIFIED TEMPERATURE RANGE --_F (_C) CERTIFIED EX STATIC PRESSURE (in. wc) AIRFLOW (CFM)} Heating Cooling Heating Cooling EFFICIENCY 036040 036060 38000 56000 38000 56000 38000 56000 38000 56000 38000 56000 38000 56000 95 93.6 94.4 94.7 93.3 94.1 036080 75000 75000 74000 75000 74000 74000 048080 75000 75000 75000 75000 75000 75000 93 91.5 92.3 92.4 91.4 91.4 060100 94000 94000 93000 94000 93000 93000 060120 113000 113000 112000 113000 112000 112000 40000 60000 80000 80000 100000 120000 036040 20---50 (11---28) 0.10 0.50 845 1260 036060 30---60 (17---33) 0.12 0.50 1040 1250 036080 40---70 (22---39) 0.15 0.50 1180 1240 048080 30---60 (17---33) 0.15 0.50 1450 1620 060100 30---60 (17---33) 0.20 0.50 1890 1635 060120 40---70 (22---39) 0.20 0.50 2065 1925 *Capacity and AFUE in accordance with U.S. Government DOE test procedures. {Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce ratings 2% for each 1000 ft. (305 M) above sea level. In Canada, derate the unit 5% for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level. }Airflow shown is for bottom only return---air supply with factory supplied 3/4---in. (19 mm) washable filter(s). For air delivery above 1800 CFM, see Air Delivery table for other options. An airflow reduction of up to 7% may occur when using the factory---specified 4 5/16---in. (110 mm) wide, high efficiency media filter. For best furnace efficiency when using the 4---5/16---in. (110 mm) wide media filter, adjust the blower speed tap to near the mid---point of the rise range. ICS --- Isolated Combustion System. 11 353AAV PERFORMANCE DATA AIR DELIVERY—CFM (WITH FILTER) UNIT SIZE RETURN-AIR SUPPLY 036040 SIDE/BOTTOM 353AAV 036060 SIDE/BOTTOM 036080 SIDE/BOTTOM 048080 SIDE/BOTTOM 060100 SIDE/BOTTOM 060120 SIDE/BOTTOM SPEED EXTERNAL STATIC PRESSURE (in.wc) 0.3 0.4 0.5 0.6 0.7 0.8 0.1 0.2 0.9 1 5(Gry) 1425 1385 1350 1305 1260 1210 1165 1100 995 855 4(Yel) 3(Blu) 2(Org) 1(Red) 1215 1060 890 880 1165 1005 835 675 1130 960 770 570 1085 910 695 475 1025 845 640 425 970 790 570 335 905 715 510 245 840 660 450 - 795 610 355 - 730 560 235 - 5(Gry) 1430 1390 1345 1300 1250 1205 1150 1080 995 845 3(Blu) 4(Yel) 1(Red) 2(Org) 1240 1090 900 805 1200 1030 835 620 1145 980 780 440 1100 935 705 380 1040 850 635 300 975 800 565 - 915 730 490 - 860 665 410 - 790 590 335 - 730 525 200 - 5(Gry) 1400 1360 1325 1285 1240 1205 1160 1125 1075 1000 3(Blu) 4(Yel) 1(Red) 2(Org) 1340 1195 1025 855 1300 1160 980 800 1265 1115 935 745 1215 1065 880 680 1180 1025 835 635 1135 985 795 560 1100 935 745 515 1055 895 685 460 1015 850 635 420 965 800 585 360 5(Gry) 1720 1695 1690 1655 1620 1580 1540 1495 1465 1415 3(Blu) 4(Yel) 2(Org) 1(Red) 1565 1330 1210 1110 1535 1310 1180 1065 1530 1270 1135 1005 1490 1220 1085 960 1450 1180 1035 910 1420 1135 995 865 1375 1095 950 820 1335 1055 910 770 1295 1010 865 720 1255 970 810 670 5(Gry) 2070 2020 1985 1925 1890 1850 1795 1755 1690 1610 3(Blu) 4(Yel) 2(Org) 1(Red) 1815 1580 1380 1170 1775 1535 1325 1105 1730 1480 1275 1055 1690 1440 1220 985 1635 1380 1220 935 1595 1380 1165 870 1555 1340 1105 805 1500 1285 1060 765 1460 1235 1000 705 1410 1185 960 660 5(Gry) 2250 2205 2155 2110 2065 2020 1970 1925 1870 1790 3(Blu) 4(Yel) 1(Red) 2(Org) 2130 1890 1640 1420 2085 1835 1585 1370 2030 1790 1525 1305 1980 1740 1475 1255 1925 1690 1425 1190 1880 1640 1365 1135 1830 1590 1315 1065 1775 1535 1260 1010 1730 1480 1200 940 1675 1435 1140 880 ] • Airflow shown is for bottom only return---air supply with factory supplied 3/4---in. (19 mm) washable filter(s). For air delivery above 1800 CFM, see Air Delivery table for other options. An airflow reduction of up to 7% may occur when using the factory---specified 4 5/16---in. (110 mm) wide, high efficiency media filter. For best furnace efficiency when using the 4 5/16---in. (110 mm) wide media filter, adjust the blower speed tap to near the mid---point of the rise range. For horizontal and downflow applications, use one side or bottom or bottom only as airflow reference. 12 COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS UNIT SIZE (BTUH) 40,000 60,000 0 to 2000 (0 to 610) 80,000 100,000 120,000 ALTITUDE FT (M) UNIT SIZE (BTUH) TERMINATION TYPE 2 Pipe or 2-in Concentric 2 Pipe or 2-in Concentric 2 Pipe or 2-in Concentric 2 Pipe or 3-in Concentric 2 Pipe or 3-in. Concentric TERMINATION TYPE 2 Pipe or 2-in Concentric 60,000 2 Pipe or 2-in Concentric 80,000 2 Pipe or 2-in Concentric 100,000 2 Pipe or 3-in Concentric 2001 to 3000 (610 to 914) 2 Pipe or 3-in. Concentric NUMBER OF 90° ELBOWS PIPE DIA IN. (mm)* 1 2 3 4 5 6 1 (25) 1 (25) 5 (1.5) NA NA NA NA NA 1-1/2 (38) 1-1/2 (38) 70 (21.3) 70 (21.3) 65 (19.8) 60 (18.3) 60 (18.3) 55 (16.8) 2 (51) 2 (51) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 1-1/2 (38) 1-1/2 (38) 20 (6.1) 15 (4.6) 10 (3.0) 5 (1.5) NA NA 2 (51) 2 (51) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 1-1/2 (38) 1-1/2 (38) 10 (3.0) NA NA NA NA NA 2 (51) 2 (51) 55 (16.8) 50 (15.2) 35 (10.7) 30 (9.1) 30 (9.1) 20 (6.1) 2-1/2 (64) 2-1/2 (64) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 2 (51) 2 (51) 5 (1.5) NA NA NA NA NA 2-1/2 (64) 2-1/2 (64) 40 (12.2) 30 (9.1) 20 (6.1) 20 (6.1) 10 (3.0) NA 3 (76) 3 (76) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 2-1/2 (64) one disk 2-1/2 (64) 10 (3.0) NA NA NA NA NA 3 (76)† NA 45 (13.7) 40 (12.2) 35 (10.7) 30 (9.1) 25 (7.6) 20 (6.1) 3 (76) † no disk 3 (76)† 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) DIRECT VENT (2-PIPE) ONLY 40,000 120,000 PIPE DIA IN. (mm)* NON-DIRECT VENT (1-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS PIPE DIA IN. (mm)* PIPE DIA IN. (mm)* 1 2 3 4 5 6 1-1/2 (38) 1-1/2 (38) 67 (20.4) 62 (18.9) 57 (17.4) 52 (15.8) 52 (15.8) 47 (14.3) 2 (51) 2 (51) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 1-1/2 (38) 1-1/2 (38) 17 (5.2) 12 (3.7) 7 (2.1) NA NA NA 2 (51) 2 (51) 70 (21.3) 67 (20.4) 66 (20.1) 61 (18.6) 61 (18.6) 61 (18.6) 2 (51) 2 (51) 49 (14.9) 44 (13.4) 30 (9.1) 25 (7.6) 25 (7.6) 15 (4.6) 2-1/2 (64) 2-1/2 (64) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 2-1/2 (64) 2-1/2 (64) 35 (10.7) 26 (7.9) 16 (4.9) 16 (4.9) 6 (1.8) NA 3 (76) 3 (76) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 66 (20.1) 61 (18.6) 3 (76) NA 14 (4.3) 9 (2.7) NA NA NA NA NA 3 (76)† 63 (19.2) 62 (18.9) 62 (18.9) 61 (18.6) 61 (18.6) 61 (18.6) 3 (76)† no disk NA 70 (21.3) 70 (21.3) 63 (19.2) 56 (17.1) 50 (15.2) 43 (13.1) 4 (102)† no disk 4 (102)† no disk 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) See notes at end of table. 13 353AAV ALTITUDE FT (M) DIRECT VENT (2-PIPE) ONLY COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.) 353AAV ALTITUDE FT (M) 3001 to 4000 (914 to 1219) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY TERMINATION TYPE 40,000 2 Pipe or 2-in Concentric 60,000 2 Pipe or 2-in Concentric 80,000 2 Pipe or 2-in Concentric 100,000 2 Pipe or 3-in Concentric 120,000 2 Pipe or 3-in. Concentric 4† no disk ALTITUDE FT (M) 4001 to 5000‡ (1219 to 1524) UNIT SIZE (BTUH) TERMINATION TYPE 2 Pipe or 2-in Concentric 60,000 2 Pipe or 2-in Concentric 80,000 2 Pipe or 2-in Concentric 100,000 2 Pipe or 3-in Concentric 2 Pipe or 3-in. Concentric NUMBER OF 90° ELBOWS PIPE DIA IN (mm)* 1 2 3 4 5 6 1-1/2 (38) 1-1/2 (38) 64 (19.5) 59 (18.0) 54 (16.5) 49 (14.9) 48 (14.6) 43 (13.1) 2 (51) 2 (51) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 1-1/2 (38) 1-1/2 (38) 16 (4.9) 11 (3.4) 6 (1.8) NA NA NA 2 (51) 2 (51) 68 (20.7) 63 (19.2) 62 (18.9) 57 (17.4) 57 (17.4) 56 (17.1) 2 (51) 2 (51) 46 (14.0) 41 (12.5) 28 (8.5) 23 (7.0) 22 (6.7) 13 (4.0) 2-1/2 (64) 2-1/2 (64) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 2-1/2 (64) 2-1/2 (64) 33 (10.1) 24 (7.3) 15 (4.6) 14 (4.3) 5 (1.5) NA 3 (76) 3 (76) 70 (21.3) 70 (21.3) 70 (21.3) 66 (20.1) 61 (18.6) 56 (17.1) 3 (76)† no disk NA 65 (19.8) 58 (17.7) 51 (15.5) 44 (13.4) 38 (11.6) 31 (9.4) NA 3 (76)† 59 (18.0) 59 (18.0) 58 (17.7) 57 (17.4) 57 (17.4) 56 (17.1) 4 (102)† no disk 4 (102) † no disk 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) DIRECT VENT (2-PIPE) ONLY 40,000 120,000 PIPE DIA IN (mm)* NON-DIRECT VENT (1-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS PIPE DIA IN. (mm)* PIPE DIA IN. (mm)* 1 2 3 4 5 6 1-1/2 (38) 1-1/2 (38) 60 (18.3) 55 (16.8) 50 (15.2) 45 (13.7) 44 (13.4) 39 (11.9) 2 (51) 2 (51) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 1-1/2 (38) 1-1/2 (38) 15 (4.6) 10 (3.0) 5 (1.5) NA NA NA 2 (51) 2 (51) 64 (19.5) 59 (18.0) 58 (17.7) 53 (16.2) 52 (15.8) 52 (15.8) 2 (51) 2 (51) 44 (13.4) 39 (11.9) 26 (7.9) 21 (6.4) 20 (6.1) 11 (3.4) 2-1/2 (64) 2-1/2 (64) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 2-1/2 (64) 2-1/2 (64) 31 (9.4) 22 (6.7) 13 (4.0) 12 (3.7) NA NA 3 (76) 3 (76) 70 (21.3) 70 (21.3) 67 (20.4) 62 (18.9) 57 (17.4) 52 (15.8) 3 (76)† no disk NA 53 (16.2) 46 (14.0) 40 (12.2) 33 (10.1) 26 (7.9) 20 (6.1) NA 3 (76)† 56 (17.1) 55 (16.8) 54 (16.5) 53 (16.2) 52 (15.8) 52 (15.8) 4 (102)† no disk 4 (102)† no disk 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) See notes at end of table. 14 COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.) 5001 to 6000‡ (1524 to 1829) UNIT SIZE (BTUH) 6001 to 7000‡ (1829 to 2134) TERMINATION TYPE 40,000 2 Pipe or 2-in Concentric 60,000 2 Pipe or 2-in Concentric 80,000 2 Pipe or 2-in Concentric 100,000 2 Pipe or 3-in Concentric 120,000 ALTITUDE FT (M) DIRECT VENT (2-PIPE) ONLY UNIT SIZE (BTUH) 2 Pipe or 3-in. Concentric PIPE DIA IN. (mm)* 40,000 2 Pipe or 2-in Concentric 60,000 2 Pipe or 2-in Concentric 80,000 2 Pipe or 2-in Concentric 100,000 2 Pipe or 3-in Concentric 120,000 2 Pipe or 3-in. Concentric NUMBER OF 90° ELBOWS PIPE DIA IN. (mm)* 1 2 3 4 5 6 1-1/2 (38) 1-1/2 (38) 57 (17.4) 52 (15.8) 47 (14.3) 42 (12.8) 40 (12.2) 35 (10.7) 2 (51) 2 (51) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 1-1/2 (38) 1-1/2 (38) 14 (4.3) 9 (2.7) NA NA NA NA 2 (51) 2 (51) 60 (18.3) 55 (16.8) 54 (16.5) 49 (14.9) 48 (14.6) 47 (14.3) 2 (51) 2 (51) 41 (12.5) 36 (11.0) 23 (7.0) 18 (5.5) 17 (5.2) 8 (2.4) 2-1/2 (64) 2-1/2 (64) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 2-1/2 (64) 2-1/2 (64) 29 (8.8) 21 (6.4) 12 (3.7) 11 (3.4) NA NA 3 (76) 3 (76) 70 (21.3) 67 (20.4) 62 (18.9) 57 (17.4) 52 (15.8) 47 (14.3) 3 (76)† no disk NA 42 (12.8) 35 (10.7) 29 (8.8) 22 (6.7) 15 (4.6) 9 (2.7) NA 3 (76)† 53 (16.2) 52 (15.8) 50 (15.2) 49 (14.9) 48 (14.6) 47 (14.3) 4 (102)† no disk 4 (102)† no disk 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) 70 (21.3) DIRECT VENT (2-PIPE) ONLY TERMINATION TYPE NON-DIRECT VENT (1-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS PIPE DIA IN. (mm)* PIPE DIA IN. (mm)* 1 2 3 4 5 6 1-1/2 (38) 1-1/2 (38) 53 (16.2) 48 (14.6) 43 (13.1 38 (11.6) 37 (11.3) 32 (9.8) 2 (51) 2 (51) 70 (21.3) 70 (21.3) 68 (20.7) 67 (20.4) 66 (20.1) 64 (19.5) 1-1/2 (38) 1-1/2 (38) 13 (4.0) 8 (2.4) NA NA NA NA 2 (51) 2 (51) 57 (17.4) 52 (15.8) 50 (15.2) 45 (13.7) 44 (13.4) 43 (13.1) 2 (51) 2 (51) 38 (11.6) 33 (10.1) 21 (6.4) 16 (4.9) 15 (4.6) 6 (1.8) 2-1/2 (64) 2-1/2 (64) 70 (21.3) 70 (21.3) 68 (20.7) 67 (20.4) 66 (20.1) 64 (19.5) 2-1/2 (64) 2-1/2 (64) 27 (8.2) 19 (5.8) 10 (3.0) 9 (2.7) NA NA 3 (76) 3 (76) 68 (20.7) 63 (19.2) 58 (17.7) 53 (16.2) 48 (14.6) 43 (13.1) 3 (76)† no disk NA 31 (9.4) 24 (7.3) 18 (5.5) 11 (3.4) NA NA NA 3 (76)† 49 (14.9) 48 (14.6) 47 (14.3) 45 (13.7) 44 (13.4) 43 (13.1) See notes at end of table. 15 353AAV ALTITUDE FT (M) COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.) ALTITUDE FT (M) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY 353AAV TERMINATION TYPE 7001 to 8000‡ (2134 to 2438) 40,000 2 Pipe or 2-in Concentric 60,000 2 Pipe or 2-in Concentric 80,000 2 Pipe or 2-in Concentric 100,000 2 Pipe or 3-in Concentric 120,000 ALTITUDE FT (M) UNIT SIZE (BTUH) 2 Pipe or 3-in. Concentric 40,000 2 Pipe or 2-in Concentric 60,000 2 Pipe or 2-in Concentric 80,000 2 Pipe or 2-in Concentric 100,000 2 Pipe or 3-in Concentric 120,000 2 Pipe or 3-in. Concentric NUMBER OF 90° ELBOWS PIPE DIA IN. (mm)* 1 2 3 4 5 6 1-1/2 (38) 1-1/2 (38) 49 (14.9) 44 (13.4) 39 (11.9) 34 (10.4) 33 (10.1) 28 (6.5) 2 (51) 2 (51) 66 (20.1) 65 (19.8) 63 (19.2) 62 (18.9) 60 (18.3) 59 (18.0) 1-1/2 (38) 1-1/2 (38) 12 (3.7) 7 (2.1) NA NA NA NA 2 (51) 2 (51) 53 (16.2) 48 (14.6) 46 (14.0) 41 (12.5) 40 (12.2) 38 (11.6) 2 (51) 2 (51) 36 (11.0) 31 (9.4) 19 (5.8) 14 (4.3) 12 (3.7) NA 2-1/2 (64) 2-1/2 (64) 66 (20.1) 65 (19.8) 63 (19.2) 62 (18.9) 60 (18.3) 59 (18.0) 2-1/2 (64) 2-1/2 (64) 25 (7.6) 17 (5.2) 8 (2.4) 7 (2.1) NA NA 3 (76) 3 (76) 63 (19.2) 58 (17.7) 53 (16.2) 48 (14.6) 43 (13.1) 38 (11.6) 3 (76)† no disk NA 20 (6.1) 13 (4.0) 7 (2.1) NA NA NA NA 3 (76)† 46 (14.0) 44 (13.4) 43 (13.1) 41 (12.5) 40 (12.2) 38 (11.6) 4 (102)† no disk 4 (102)† no disk 61 (18.6) 56 (17.1) 51 (15.5) 46 (14.0) 41 (12.5) 36 (11.0) DIRECT VENT (2-PIPE) ONLY TERMINATION TYPE 8001 to 9000‡ (2438 to 2743) PIPE DIA IN. (mm)* NON-DIRECT VENT (1-PIPE) ONLY PIPE DIA IN. (mm)* NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS PIPE DIA IN. (mm)* 1 2 3 4 5 6 1-1/2 (38) 1-1/2 (38) 46 (14.0) 41 (12.5) 36 (11.0) 31 (9.4) 29 (8.8) 24 (7.3) 2 (51) 2 (51) 62 (18.9) 60 (18.3) 58 (17.7) 56 (17.1) 55 (16.8) 53 (16.2) 1-1/2 (38) 1-1/2 (38) 11 (3.4) 6 (1.8) NA NA NA NA 2 (51) 2 (51) 49 (14.9) 44 (13.4) 42 (12.8) 37 (11.3) 35 (10.7) 34 (10.4) 2 (51) 2 (51) 33 (10.1) 28 (8.5) 17 (5.2) 12 (3.7) 10 (3.0) NA 2-1/2 (64) 2-1/2 (64) 62 (18.9) 60 (18.3) 58 (17.7) 56 (17.1) 55 (16.8) 53 (16.2) 2-1/2 (64) 2-1/2 (64) 23 (7.0) 15 (4.6) 7 (2.1) 5 (1.5) NA NA 3 (76) 3 (76) 59 (18.0) 54 (16.5) 49 (14.9) 44 (13.4) 39 (11.9) 34 (10.4) 3 (76)† no disk NA 10 (3.0) NA NA NA NA NA NA 3 (76)† 43 (13.1) 41 (12.5) 39 (11.9) 37 (11.3) 35 (10.7) 34 (10.4) 4 (102)† no disk 4† no disk 35 (10.7) 30 (9.1) 25 (7.6) 20 (6.1) 15 (4.6) 10 (3.0) See notes at end of table. 16 COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.) UNIT SIZE (BTUH) NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA IN. (mm)* PIPE DIA IN. (mm)* 1 2 3 4 5 6 2 Pipe or 2-in 1-1/2 (38) 1-1/2 (38) 42 (12.8) 37 (11.3) 32 (9.8) 27 (8.2) 25 (7.6) 20 (6.1) Concentric 2 (51) 2 (51) 57 (17.4) 55 (16.8) 53 (16.2) 51 (15.5) 49 (14.9) 47 (14.3) 60,000 2 Pipe or 2-in Concentric 2 (51) 2 (51) 45 (13.7) 40 (12.2) 38 (11.6) 33 (10.1) 31 (9.4) 29 (8.8) 2 Pipe or 2-in Concentric 2 (51) 2 (51) 30 (9.1) 25 (7.6) 14 (4.3) 9 (2.7) 7 (2.1) NA 80,000 2-1/2 (64) 2-1/2 (64) 57 (17.4) 55 (16.8) 53 (16.2) 51 (15.5) 49 (14.9) 47 (14.3) 2 Pipe or 3-in Concentric 2-1/2 (64) 2-1/2 (64) 21 (6.4) 13 (4.0) 5 (1.5) NA NA NA 100,000 3 (76) 3 (76) 54 (16.5) 49 (14.9) 44 (13.4) 39 (11.9) 34 (10.4) 29 (8.8) 2 Pipe or 3-in. Concentric NA 3 (76)† 120,000 39 (11.9) 37 (11.3) 35 (10.7) 33 (10.1) 31 (9.4) 29 (8.8) 4 (102)† no disk 4 (102)† no disk 10 (3.0) 5 (1.5) NA NA NA NA 40,000 9001 to 10,000‡ (2743 to 3048) DIRECT VENT (2-PIPE) ONLY * Disk usage-Unless otherwise specified, use perforated disk assembly (factory-supplied in loose parts bag). # If one disk is stated, separate 2 halves of perforated disk assembly and use shouldered disk half. When using shouldered disk half, install screen side toward inlet box. † Wide radius elbow. ‡ Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by the local authorities having jurisdiction. NA-Not Allowed; pressure switch will not make. NOTES: 1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur. 2. Size both the combustion-air and vent pipe independently, then use the larger diameter for both pipes. 3. Assume two 45° elbows equal one 90° elbow. Wide radius elbows are desirable and may be required in some cases. 4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count. 5. The minimum pipe length is 5 ft (1.5 M) for all applications. 6. Use 3-in. (76 mm) diameter vent termination kit for installations requiring 4-in (102 mm) diameter pipe. 17 353AAV ALTITUDE FT (M) MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH -- FT (M) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* FURNACE SIZE 040 353AAV 060 080 100 120 WINTER DESIGN TEMPERATURE °F 〈°C) MAX PIPE DIAMETER IN (mm) WITHOUT INSULATION FT (M) WITH 3/8–IN. OR THICKER INSULATION† FT (M) 20 (---7) 0 (---18) ---20 (---29) 20 (---7) 0 (---18) ---20 (---29) 20 (---7) 0 (---18) ---20 (---29) 20 (---7) 0 (---18) ---20 (---29) 20 (---7) 0 (---18) ---20 (---29) 20 (---7) 0 (---18) ---20 (---29) 20 (---7) 0 (---18) ---20 (---29) 20 (---7) 0 (---18) ---20 (---29) 20 (---7) 0 (---18) ---20 (---29) 1.5 (38) 1.5 (38) 1.5 (38) 2 (51) 2 (51) 2 (51) 2 (51) 2 (51) 2 (51) 2 (51) 2 (51) 2 (51) 2.5 (64) 2.5 (64) 2.5 (64) 2.5 (64) 2.5 (64) 2.5 (64) 3 (76) 3 (76) 3 (76) 3 (76) 3 (76) 3 (76) 4 (102) 4 (102) 4 (102) 51 (16) 28 (9) 16 (5) 45 (14) 22 (7) 10 (3) 65 (20) 35 (11) 20 (6) 55 (17) 48 (15) 30 (9) 70 (21) 47 (14) 28 (9) 40 (12) 40 (12) 38 (12) 70 (21) 50 (15) 28 (9) 70 (21) 61 (19) 37 (11) 70 (21) 48 (15) 23 (7) 70 (21) 70 (21) 70 (21) 70 (21) 70 (21) 58 (18) 70 (21) 70 (21) 70 (21) 55 (17) 55 (17) 55 (17) 70 (21) 70 (21) 70 (21) 40 (12) 40 (12) 40 (12) 70 (21) 70 (21) 70 (21) 70 (21) 70 (21) 70 (21) 70 (21) 70 (21) 70 (21) * Pipe length ft (M) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe length as specified in Table. † Insulation thickness based on R value of 3.5 per in. 18 ELECTRICAL DATA UNIT SIZE UNIT VOLTS --- HERTZ --- PHASE MAXIMUM UNIT AMPS UNIT AMPACITY MINIMUM WIRE SIZE MAXIMUM WIRE LENGTH --- FT (M) MAXIMUM FUSE OR CKT BKR (Amps)** TRANSFORMER (24v) HEATING EXTERNAL CONTROL POWER AVAILABLE COOLING AIR CONDITIONING BLOWER RELAY 036040 115---60---1 8 10.8 14 34 (10.3) 15 036060 115---60---1 9.4 12.5 14 29 (8.8) 15 036080 048080 115---60---1 115---60---1 9.4 9.6 12.5 12.8 14 14 29 (8.8) 29 (8.8) 15 15 40va 12va 21va 24v Standard 060100 115---60---1 12.1 15.9 12 36 (10.9) 20 060120 115---60---1 12.1 15.9 12 36 (10.9) 20 353AAV TYPICAL WIRING SCHEMATIC FIELD 24-V WIRING FIELD 115-, 208/230-, 460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING NOTE 2 W FIVE WIRE THREE-WIRE HEATING-ONLY C R G Y THERMOSTAT TERMINALS FIELD-SUPPLIED DISCONNECT 208/230- OR 460-V THREE PHASE BLOWER DOOR SWITCH BLK BLK WHT WHT GND 115-V FIELDSUPPLIED DISCONNECT W GND AUXILIARY J-BOX C O N T R O L R 208/230-V SINGLE PHASE G COM GND NOTE 1 CONDENSING UNIT Y/Y2 24-V TERMINAL BLOCK FURNACE TWO WIRE NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation. 2. Some thermostats require a "C" terminal connection as shown. 3. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire. A99440 19 TYPICAL INSTALLATIONS COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) OUTDOOR UNIT VENT PIPE A/C COIL 353AAV HUMIDIFIER COMBUSTION AIR INLET (NON-DIRECT 1-PIPE APPLICATION) GAS-FIRED WATER HEATER ELECTRONIC AIR CLEANER FRONT OF FURNACE AIRFLOW A05064 Upflow Application ELECTRONIC AIR CLEANER VENT COMBUSTION AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION COMBUSTION AIR (DIRECT VENT/ 2 PIPE APPLICATION HUMIDIFIER OUTDOOR UNIT A/C COIL AIRFLOW FRONT OF FURNACE A05065 Downflow Application 20 TYPICAL INSTALLATIONS (CONTINUED) COMBUSTION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) COMBUSTION–AIR PIPE DIRECT VENT/2-PIPE APPLICATION) 353AAV VENT PIPE ELECTRONIC AIR CLEANER FRONT OF FURNACE FURNACE CONDENSATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW A05066 Attic -- Horizontal Application COMBUSTION– AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) COMBUSTION - AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION) VENT PIPE REFRIGERATION PIPING AIR CONDITIONING COIL ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN FRONT OF FURNACE A08422 Crawlspace -- Horizontal Application 21 GUIDE SPECIFICATIONS Filters Plus 90x Furnace shall have reusable--type filters. Filter shall be ______ in (x) ______in. An accessory high efficiency Media Filter is available as an option. ______________Media Filter. Single--Stage/Deluxe Gas Furnace 353AAV GENERAL System Description Casing Casing shall be of .030 in. (.03 mm) thickness minimum, pre--painted galvanized steel. Furnish a _________________ (4--way multipoise) fixed capacity gas--fired condensing furnace for use with natural gas or propane (factory authorized conversion kit required for propane); furnish cold air return plenum; furnish external medial cabinet for use with accessory media filter or standard filter. 353AAV Quality Assurance Unit will be designed, tested and constructed to the current ANSI Z 21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit will be 3rd party certified by CSA to the current ANSI Z 21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit will carry the CSA Blue Star® and Blue Flame® labels. Unit efficiency testing will be performed per the current DOE test procedure as listed in the Federal Register. Unit will be certified for capacity and efficiency and listed in the latest GAMA Consumer’s Directory of Certified Efficiency Ratings. Unit will carry the current Federal Trade Commission Energy Guide efficiency label. Delivery, Storage and Handling Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendation. Warranty (for inclusion by specifying engineer) U.S. and Canada only. request. Warranty certificate available upon Inducer motor shall be soft mounted to reduce vibration transmission. Primary Heat Exchangers Primary Heat exchangers shall be 3--Pass 20 gauge corrosion resistant aluminized steel of fold--and--crimp sectional design, which operates under negative pressure. Secondary Heat Exchangers Secondary Heat exchangers shall be of a flow--through design having a patented interior laminate coating of polypropylene for greater corrosion resistance with fold--and--crimp design, which operates under negative pressure. Controls Controls shall include a microprocessor based integrated electronic control board with at least 11 service troubleshooting codes displayed via diagnostic flashing LED light on the control, has ability to store fault codes, when activated a self--test feature checks all major functions of the furnace within one minute, and a replaceable automotive--type circuit protection fuse. Multiple operational settings available including separate blower speeds. Cooling airflow will be selectable between 350 or 400 CFM per ton of air conditioning. Features will also include temporary reduced airflow in the cooling mode for improved dehumidification when a Thermidistat® is selected as the thermostat. Operating Characteristics PRODUCTS Equipment Components shall include: slow--opening gas valve to reduce ignition noise, regulate gas flow, with electric switch gas shut--off; flame proving sensor, hot surface igniter, pressure switch assembly verifies inducer operation; flame rollout switch, drain tubing and installed condensate drain trap, blower and inducer assembly, 40va transformer; low--voltage (heating) (heating/ cooling) thermostat. Blower Wheel and Blower Motor Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed bearings, of _____ hp, and shall be multiple--speed direct drive. Blower motor shall be soft mounted to the blower scroll to reduce vibration transmission. E2010 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Inducer Motor Heating Capacity shall be_________Btuh input;____________Btuh output capacity. Fuel Gas Efficiency shall be 93% AFUE. Air delivery shall be__________ CFM minimum at 0.50 in. wc. external static pressure. Dimensions shall be: depth__________in.; width__________in.; height _________in. (casing only). Height shall be__________in. with A/C coil and____________in. overall with plenum. Electrical Requirements Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal). Minimum wire size shall be_________AWG; maximum fuse size or HACR--type, designated circuit breaker shall be _______Amps. Special Features Refer to section of the product data sheet identifying accessories and descriptions for specific features and available enhancements. Printed in U.S.A. Edition Date: 09/10 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 22 Catalog No. PDS353AAV--- 03 Replaces: PDS353AAV---02
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Creator : BACT559 Title : PDS353AAV-03 Create Date : 2010:09:08 16:31:27-04:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2010:09:08 16:31:27-04:00 Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:f45aee07-645a-4152-8d71-6d3a40246634 Instance ID : uuid:167aec62-b007-4aa3-9f41-d1ded6bc3f95 Page Count : 22 Author : BACT559EXIF Metadata provided by EXIF.tools