Bryant Quantum Plus 650A Users Manual
650A to the manual d24a0fc4-7fd3-45a4-8e1e-111800967b9f
2015-02-02
: Bryant Bryant-Quantum-Plus-650A-Users-Manual-412059 bryant-quantum-plus-650a-users-manual-412059 bryant pdf
Open the PDF directly: View PDF .
Page Count: 20
Download | ![]() |
Open PDF In Browser | View PDF |
QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON™ REFRIGERANT The Quantum Plus line of split-system outdoor units has been expanded to include the Model 650A 13 SEER heat pump (with efficiencies up to 14.5 SEER). Homeowners will appreciate the Quantum Plus with Puron Refrigerant because of its efficiency, environmental soundness and its availability for years to come. Another benefit of the Quantum Plus is the durability of the scroll compressor. Model 650A has received certifications from UL, c-UL, ARI, CEC, and CSA-EEV. The 650A is also approved by Energy StarSM for energy efficiency and by Green Seal for efficiency and environmental soundness. FEATURES REFRIGERANT—The environmentally sound refrigerant used in the 650A is Puron. This advanced refrigerant contains no chlorine which can contribute to ozone depletion in the atmosphere, so it’s a smart choice for homeowners who are concerned with protecting our environment, now and for future generations. And it’s a smart choice for anyone interested in high-efficiency cooling. RELIABLE BUILT-IN COMPONENTS—All units include a suction line accumulator that minimizes the amount of liquid refrigerant that reaches the compressor; a high-pressure switch for high-pressure protection; a low-pressure switch for loss of charge protection; and a liquid-line filter drier to remove any moisture or foreign matter from the system. A crankcase heater is standard on the 048 and 060 sizes. COMPRESSOR PROTECTION—Each scroll compressor motor is protected with internal temperature and currentsensitive overloads. For improved serviceability each compressor is equipped with a compressor terminal plug. UNIT DESIGN—Copper tube, enhanced aluminum fin coil is designed for strong heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan is popular for its easy removal of water, dirt, and leaves. The AeroQuiet System (AQS) consists of 4 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening and 650A (60 Hz) Sizes 024 thru 060 wire dome top results in quieter and more efficient operation. Energy-Efficient Fan and Fan Motor provide a slower fan operation, thus reducing noise and improving efficiency. Sound Hood muffles noise from operation. Discharge Muffler minimizes low frequency sound and pressure pulsation generated by compressor discharge gas. WEATHER-PROTECTIVE CABINET—Steel is galvanized and coated with a layer of zinc phosphate. A layer of modified polyester powder is then applied and baked on, providing each unit with a durable finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rust-resistant, quality appearance. COIL PROTECTION—The DuraGuard coil protector, made of a 12 gage coated steel wire grid with vertical 3/8-in. spacing, is designed to help protect the coil from inclement weather, vandalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning. EASY SERVICEABILITY—One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil. WIDE RANGE OF SIZES—Available in 6 nominal sizes from 024 through 060 to meet the needs of residential and light commercial applications. LIMITED WARRANTY—Standard 1-year limited warranty on parts, with an additional 9-year limited warranty on compressor. TOTALLY ENCLOSED FAN MOTOR—Means greater reliability under adverse weather conditions and dependable performance for many years. Permanent split-capacitor-type motors provide more economical operation. DEFROST CONTROL BOARD—Incorporates a built-in 5-minute compressor time-delay relay, defrost relay, defrost timer, and low-voltage terminal board. The defrost control is a time/temperature initiation/termination control, which includes 3 field-selectable time periods of 30, 50, and 90 minutes. APPLICATION VERSATILITY—Due to PressureGuard™ the 650A can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. The 650A can be installed on a roof or at ground level on a slab. EXTERNAL SERVICE VALVES—Both service valves are brass, back seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. THERMOSTATIC EXPANSION VALVE (TXV)—This unit must be installed with a Puron™ approved TXV on the indoor coil. The FX4 and FV4 fan coils come factory equipped with Puron TXVs. When installed with these fan coils, no further change is required. For any other coil combination, the approved field accessory Puron TXV must be installed. For applications with fan coils such as the FC4 and FK4 which have R-22 TXVs, the R-22 TXV must be replaced with the approved field accessory Puron TXV. ELECTRICAL RANGE—All units are offered in 208/230v single phase only. Form No. PDS 650A.24.2 UNIT SIZE 024 030 036 042 048 060 —2— SERIES A,C A,C A,C A,C A,C B,C A 39-13/16 33-13/16 27-13/16 27-13/16 39-13/16 39-13/16 AIR DISCHARGE AIR IN AIR DISCHARGE L B 30 30 30 30 30 30 AIR IN AIR IN C 33 33 33 33 33 33 8 3/16" C L D 5-1/16 5-1/16 5-1/16 5-1/16 5-1/16 5-1/16 E D K E 9-11/16 9-11/16 9-11/16 9-11/16 9-11/16 9-11/16 N 1 9/16" 2 1/2" UNIT DIMENSIONS F G 27-15/16 34-3/8 21-15/16 28-3/8 15-15/16 22-3/8 15-15/16 22-3/8 27-15/16 34-3/8 27-15/16 34-3/8 DIMENSIONS (IN.) AIR DISCHARGE C 3/8 IN. DIA (9.5) TIEDOWN KNOCKOUTS (2) PLACES IN BASEPAN H 5/8 3/4 3/4 7/8 7/8 7/8 K 15-7/8 14 16-1/8 16-1/4 16-1/4 16 1 3/4" 4" L 14-3/8 13-1/8 14-1/8 14 14-1/4 13-3/4 10 1/2" 3/8 IN. DIA LIQUID LINE CONN LINE CONN H DIA SUCTION FIELD CONTROL SUPPLY CONN 7/8 IN. DIA HOLE F G M M 14-1/4 13-3/4 13-1/4 13-1/8 14-1/2 14 A N 2-15/16 2-15/16 2-15/16 2-15/16 2-15/16 2-15/16 1 1/4" FIELD POWER SUPPLY CONN 7/8 IN. DIA (22.22) HOLE WITH 1 1/8 IN. DIA (34.92) KNOCKOUT AND 1 3/8 IN. DIA KNOCKOUT 1.Allow 30 in. clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2.Minimum outdoor operating ambient in cooling mode is 55°F (unless low ambient control is used) max 125°F. 3.Maximum outdoor operating ambient in heating mode is 66°F. 4.Series designation is the 14th position of the unit model number. 5.Center of gravity . NOTES: MINIMUM MOUNTING PAD DIMENSIONS Support Feet Snow Stand 26 x 32 31 x 35 26 x 32 31 x 35 26 x 32 31 x 35 26 x 32 31 x 35 26 x 32 31 x 35 26 x 32 31 x 35 A94148 ACCESS PANEL B DIMENSIONS RECOMMENDED TUBE DIAMETERS LIQUID TUBE DIAMETER (IN.) 0 to 50 Ft Tube Length Alternate 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 UNIT SIZE 024 030 036 042, 048 060 VAPOR TUBE DIAMETER (IN.) 0 to 50 Ft Tube Length 5/8 3/4 3/4 7/8 1-1/8 Alternate 3/4 ACR 7/8 7/8 7/8 7/8 RST* (Not Permitted) 3/4 1-1/8 1-1/8 3/4 and 1-1/8 3/4 * RST—Refrigeration Service Tubing, standard refrigerant grade tubing. NOTES: 1. Tube diameters are for lengths up to 50 ft. For tubing lengths greater than 50 ft, consult the Application Guideline and Service Manual for Residential SplitSystem Air Conditioners and Heat Pumps using Puron Refrigerant. 2. Refrigerant tubes and indoor coils must be evacuated to 500 microns to minimize contamination and moisture in the system. METERING DEVICE UNIT SIZE 024 030 036 042 048 060 SERIES A,C A,C A,C A,C A,C B,C OUTDOOR PISTON 46 52 57 59 61 73 INDOOR TXV* KSATX0201HSZ KSATX0201HSZ KSATX0301HSZ KSATX0301HSZ KSATX0401HSZ KSATX0501HSZ REQUIRED SUBCOOLING (°F) 11 9 9 11 10 12 * TXV must be installed when indoor coil is not equipped with a Puron approved TXV. TXV listed is for any approved coil combination. All TXVs are Puron specific bi-flow hard shutoff. SOUND RATING (dBA) UNIT SIZE–SERIES 024-A,C 030-A,C 036-A,C 042-A,C 048-A,C 060-B,C Meets GREEN SEAL Environmental Criteria for high energy efficiency, low noise, and recycled packaging. Does not use an ozone depleting substance during manufacturing, or as a refrigerant. A AIR CO Y NING ITIO ND UNIT AR T IFIED O ARI A RT S C CE EQ RI YING WITH PL OM MANUFACTUR ER As an ENERGY STARSM partner, Bryant Heating & Cooling Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency. SOUND RATING 72 74 76 76 78 78 UIP M E N T STA NDARD 21 0 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. REGISTERED QUALITY SYSTEM —3— SPECIFICATIONS UNIT SIZE-SERIES Operating Weight (Lb) 024-A,C 030-A,C 036-A,C 214 205 217 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187—253 Compressor Rated Load Amps 15.1 14.7 15.4 Compressor Locked Rotor Amps 61.0 72.5 83.0 Condenser Fan Motor—Full Load Amps 0.8 1.1 1.1 Minimum Unit Ampacity for Wire Sizing 19.7 19.5 20.4 Minimum Wire Size (60°C Copper) (AWG)† 14 14 12 Minimum Wire Size (75°C Copper) (AWG)† 14 14 12 Maximum Wire Length (60°C) (Ft)‡ 39 39 60 Maximum Wire Length (75°C) (Ft)‡ 37 37 57 Maximum Branch Circuit Fuse Size** 30 30 30 COMPRESSOR & REFRIGERANT Compressor Manufacturer Copeland Compressor Type Scroll Refrigerant Type Puron Refrigerant Amount (Lb)†† 7.18 6.63 8.87 OUTDOOR COIL & FAN Coil Face Area (Sq Ft) Fins per In.—Rows—Circuits Fan Motor—HP & RPM Rated Airflow (CFM) 18.18 15.15 12.12 25—1—2 25—1—3 20—2—3 1/8 and 825 1/5 and 825 1/5 and 825 2400 2800 2800 OPTIONAL EQUIPMENT Support Feet—4 In. (4) KSASF0101AAA Snow Stand—18 In. Time Delay Relay KHASS0206MPK KAATD0101TDR Interface Control (Energy Minder)‡‡ KHAIC0101AAA Service Alarm*** KHASA0101AAA Outdoor Thermostat KHAOT0301FST Secondary Outdoor Thermostat KHAOT0201SEC Crankcase Heater KAACH1201AAA Start Assist—Capacitor/Relay Type KSAHS1501AAA Start Assist—PTC Type Standard Bi-Flow TXV (Hard Shutoff) KSATX0201HSZ Filter Drier (Suction Line) KH45LG140 (RCD) Evaporator Freeze Thermostat††† KAAFT0101AAA Isolation Relay††† KHAIR0101AAA Liquid-Line Solenoid Valve (LSV) KHALS0401LLS Low-Ambient Pressure Switch KSALA0301410 See notes on page 5. —4— KSATX0301HSZ SPECIFICATIONS Continued UNIT SIZE-SERIES Operating Weight (Lb) 042-A.C 048-A,C 060-B,C 218 266 295 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187—253 Compressor Rated Load Amps 21.1 20.5 27.6 Compressor Locked Rotor Amps 104.0 109.0 158.0 Condenser Fan Motor—Full Load Amps 1.1 1.4 1.4 Minimum Unit Ampacity for Wire Sizing 27.5 27.0 35.9 Minimum Wire Size (60°C Copper) (AWG)† 10 10 8 Minimum Wire Size (75°C Copper) (AWG)† 10 10 8 Maximum Wire Length (60°C) (Ft)‡ 71 74 86 Maximum Wire Length (75°C) (Ft)‡ 68 70 82 Maximum Branch Circuit Fuse Size** 40 40 60 COMPRESSOR & REFRIGERANT Compressor Manufacturer Copeland Compressor Type Scroll Refrigerant Type Puron Refrigerant Amount (Lb)†† 8.63 13.25 13.25 OUTDOOR COIL & FAN Coil Face Area (Sq Ft) Fins per In.—Rows—Circuits Fan Motor—HP & RPM Rated Airflow (CFM) 12.12 18.18 18.18 20—2—3 20—2—4 20—2—5 1/5 and 825 1/4 and 1100 1/4 and 1100 2800 3300 3300 OPTIONAL EQUIPMENT Support Feet—4 In. (4) KSASF0101AAA Snow Stand—18 In. Time Delay Relay KHASS0206MPK KAATD0101TDR Interface Control (Energy Minder)‡‡ KHAIC0101AAA Service Alarm*** KHASA0101AAA Outdoor Thermostat KHAOT0301FST Secondary Outdoor Thermostat KHAOT0201SEC Crankcase Heater KAACH1201AAA Standard Start Assist—Capacitor/Relay Type KSAHS1501AAA KSAHS1601AAA Start Assist—PTC Type Bi-Flow TXV (Hard Shutoff) Standard KSATX0301HSZ Filter Drier (Suction Line) KAACS0201PTC KSATX0401HSZ KSATX0501HSZ KH45LG141 (RCD) Evaporator Freeze Thermostat††† KAAFT0101AAA Isolation Relay††† KHAIR0101AAA Liquid-Line Solenoid Valve (LSV) KHALS0401LLS Low-Ambient Pressure Switch KSALA0301410 * Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure. † If other than uncoated (non-plated), 60°C or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. ‡ Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 percent. ** Time-delay fuse or circuit breaker. †† The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, refer to the Residential Split-Systems Long-Line Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using Puron (R-410A). ‡‡ Outdoor thermostat required. *** For indicator function, thermostat specified must be used and wired according to service alarm Installation Instructions. ††† Use with low-ambient pressure switch. NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. —5— THERMOSTATS AND ACCESSORIES Thermostat—Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool TSTATBBNHP01-B Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool TSTATBBPHP01-B Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, Dual Fuel, Includes Outdoor Sensor (TSTATXXSEN01) TSTATBBPDF01-B* Thermidistat™ Control—Non-Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) TSTATBBPRH01-B* Builder’s Thermostat—Manual Changeover, Non-Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool, Heat Pump TSTATBBBHP01* Outdoor Air Temperature Sensor TSTATXXSEN01 Backplate for Non-Programmable Thermostat TSTATXXNBP01† Backplate for Programmable Thermostat and Thermidistat™ Control TSTATXXPBP01† Backplate for Builder’s Thermostat TSTATXXBBP01† Thermostat Conversion Kit (4 to 5 Wire)—10 Pack TSTATXXCNV10‡ * Do not use in zoning heat pump applications. † This plate is designed to cover surrounding wall area located behind thermostat. ‡ Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed. ** Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version and builder’s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the dual fuel thermostat. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat. ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55°F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) Crankcase Heater Yes Yes Evaporator Freeze Thermostat Yes No Compressor Start Assist—Capacitor and Relay Yes Yes Puron Low-Ambient Pressure Switch Yes No Wind Baffle See Low-Ambient Pressure Switch Instructions No Support Feet Recommended No Puron Hard Shutoff TXV Yes† Yes† Puron Liquid-Line Solenoid Valve for Heating No See Long-Line Application Guideline * For tubing line sets between 50 and 175 ft and/or 20 ft elevation difference between indoor and outdoor units, refer to the Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using Puron Refrigerant. † Required for all applications. —6— ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Compressor Start Assist—Capacitor and Relay Start capacitor and start relay which gives a “hard” boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105°F (40.6°C). Units installed with Low Ambient Pressure Switch. Units installed with Liquid-Line Solenoid Valve. 2. Compressor Start Assist—PTC Type Solid-state electrical device which gives a “soft” boost to the compressor at each start-up. SUGGESTED USE: Installations with marginal power supply. 3. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55°F (12.8°C) outdoor air temperature. (Use with Low-Ambient Pressure Switch.) All commercial installations. 4. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units to which Low-Ambient Pressure Switch has been added. 5. Filter Drier—Suction Line A device for removing contaminants from refrigerant circulating in a heat pump system; 2-direction flow for heat pumps. SUGGESTED USE: Split-system heat pumps. 6. Interface Control (Energy Minder) An electric control for controlling a heat pump and gas or oil furnace system for maximum energy savings. It allows heat pump to operate down to a predetermined economic balance point temperature, then switches to allow furnace operation only below that temperature. Requires outdoor thermostat (Item 11) to be adjusted for economic balance point temperature. SUGGESTED USE: For heat pump and gas- or oil-fired furnace combination systems unless Duel Fuel Thermostat or Thermidistat™ Control is used. 7. Isolation Relay An SPDT relay which switches the Low-Ambient Controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. SUGGESTED USE: All heat pumps where Low-Ambient Pressure Switch has been added. 8. Liquid-Line Solenoid Valve (LSV) An electrically operated shutoff valve to be installed at the outdoor unit which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. SUGGESTED USE: In long-line applications. (Refer to the Residential Split-System Long-Line Application Guideline and Service Manual.) 9. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at low-ambient temperatures down to 0°F (–17.8°C) when properly installed. SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C). 10. Outdoor Air Temperature Sensor A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat. SUGGESTED USE: All Bryant programmable thermostats. 11. Outdoor Thermostat An SPDT temperature actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below set point. SUGGESTED USE: Heat pump installations with multiple-stage supplemental heaters. 12. Secondary Outdoor Thermostat An SPDT temperature actuated switch which turns on a third stage of supplemental electric heaters when outdoor air temperature drops below the second-stage set point. SUGGESTED USE: Heat pump installations where 3-stage operation of supplemental heaters is desired. 13. Service Alarm A current-sensing lockout relay which provides immediate notification that compressor is not operating during a call for heating or cooling. Used with proper room thermostat, a thermostat signal is turned on signifying service is required. This can minimize electrical cost increase due to operation of supplemental heaters only. SUGGESTED USE: As a feature to notify owner immediately when the system is not operating most efficiently. 14. Snow Stand Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base. SUGGESTED USE: Heat pump installations in heavy snowfall areas. Heat pump installations in snowdrift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 15. Support Feet Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base; minimizes corrosion. SUGGESTED USE: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. 16. Thermostatic Expansion Valve (TXV)—Bi-Flow A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. SUGGESTED USE: Required for all installations. 17. Time-Delay Relay An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. (Refer to ARI Unitary Directory.) Required for use on all zoning systems. —7— COMBINATION RATINGS* UNIT SIZESERIES 024-A,C 030-A,C 036-A,C 042-A,C 048-A,C INDOOR UNIT FX4ANF030† F(A,B)4AN(F,C)030 FC4BNF030 FK4CNF001 FK4CNF002 FK4CNF003 FV4ANF002 FV4ANF003 CC5A/CD5AA036 CD5AW036 CE3AA036 CJ5A/CK5A/CK5BA036 CJ5A/CK5A/CK5BW036 CJ5A/CK5A/CK5BN036 CK3BA036 FX4ANF030† F(A,B)4AN(F,C)036 FC4BNF036 FK4CNF001 FK4CNF002 FK4CNF003 FV4ANF002 FV4ANF003 FX4ANF036 CC5A/CD5AA036 CD5AW036 CE3AA036 CJ5A/CK5A/CK5BN036 CJ5A/CK5A/CK5BW036 CK3BA036 FX4ANF042† F(A,B)4AN(F,B,C)042 FC4BN(F,B)042 FK4CNF003 FK4CNF005 FV4ANF003 FV4ANF005 CC5A/CD5AA042 CC5A/CD5AW042 CC5A/CD5AC048 CC5A/CD5AW048 CD5AA048 CE3AA042 CE3AA048 CJ5A/CK5A/CK5BA042 CJ5A/CK5A/CK5BN042 CJ5A/CK5A/CK5BA048 CJ5A/CK5A/CK5BN048 CJ5A/CK5A/CK5BW048 CK3BA042 CK3BA048 FV4ANF003† F(A,B)4AN(F,B,C)048 FC4BN(F,B)048 FK4CNF003 FK4CNF005 FV4ANF005 FX4ANF042 CE3AA048 CJ5A/CK5A/CK5BA048 CJ5A/CK5A/CK5BN048 CJ5A/CK5A/CK5BW048 CK3BA048 FV4ANF005† F(A,B)4AN(F,B,C)060 FB4ANB070 FC4BN(F,B)060 FC4BNB070 FK4CNF005 FK4CNB006 FV4ANB006 FX4ANF048 FX4ANB060 CE3AA060 CFM†† 800 800 800 700 700 700 700 700 900 900 800 800 800 800 800 1050 1050 1050 875 875 875 875 875 1050 1080 1080 1050 1000 1050 1050 1125 1125 1125 1050 1050 1050 1050 1125 1260 1260 1275 1275 1125 1125 1125 1125 1125 1125 1125 1125 1125 1225 1400 1400 1225 1225 1225 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 TC 25,000 23,600 24,000 24,400 25,200 25,200 25,200 25,200 24,000 24,000 23,800 24,200 24,200 24,200 24,200 29,000 28,400 28,400 28,600 28,800 29,000 29,200 29,400 29,000 28,800 28,800 28,600 28,800 28,800 28,800 35,000 33,600 33,600 34,000 35,400 34,400 35,600 34,000 33,600 33,600 34,000 34,000 34,000 34,200 33,800 33,800 34,200 34,200 34,200 33,800 34,200 40,500 40,000 40,500 40,500 41,000 41,000 40,500 40,500 40,000 40,000 40,000 4,0000 45,500 44,500 46,000 44,500 46,000 45,500 46,500 46,500 45,000 45,500 45,500 ARI STANDARD RATINGS* Cooling Seasonal Efficiency SEER Field-Supplied High-Temp FactoryAccessory‡ Supplied Enhance- Standard Puron Puron TXV TXV & TDR** EER TC COP ment Rating TDR&TXV 13.00 — — 11.10 25,000 3.30 TDR — 12.50 — 10.95 24,400 3.18 TDR — 12.50 — 10.95 24,400 3.18 TDR — 13.80 — 12.00 23,800 3.30 TDR — 14.00 — 12.35 25,000 3.58 TDR — 14.20 — 12.60 25,200 3.54 TDR&TXV 14.20 — — 12.05 25,200 3.44 TDR&TXV 14.50 — — 12.35 25,000 3.44 NONE — — 13.00 11.10 24,800 3.28 NONE — — 13.00 11.10 24,800 3.28 NONE — — 12.60 11.05 24,600 3.20 NONE — — 13.00 11.20 24,800 3.34 NONE — — 13.00 11.20 24,800 3.34 NONE — — 13.00 11.20 24,800 3.34 NONE — — 13.00 11.20 24,800 3.34 TDR&TXV 13.00 — — 11.15 30,000 3.56 TDR — 12.20 — 10.75 29,800 3.42 TDR — 12.20 — 10.75 29,800 3.42 TDR — 13.70 — 12.10 28,600 3.54 TDR — 13.70 — 12.15 29,000 3.68 TDR — 14.20 — 12.55 28,600 3.68 TDR&TXV 14.00 — — 12.15 29,000 3.68 TDR&TXV 14.50 — — 12.55 28,600 3.70 TDR&TXV 12.30 — — 10.85 30,000 3.52 NONE — — 13.00 11.25 29,400 3.52 NONE — — 13.00 11.25 29,400 3.52 NONE — — 12.70 11.15 29,200 3.44 NONE — — 12.70 11.25 29,400 3.54 NONE — — 13.00 11.30 29,400 3.56 NONE — — 13.00 11.30 29,400 3.56 TDR&TXV 13.00 — — 10.80 35,000 3.40 TDR — 12.30 — 10.65 34,200 3.26 TDR — 12.30 — 10.65 34,200 3.26 TDR — 13.70 — 11.80 33,600 3.40 TDR — 14.00 — 12.30 33,800 3.70 TDR&TXV 13.70 — — 11.80 33,600 3.44 TDR&TXV 14.00 — — 12.30 34,000 3.70 NONE — — 12.50 10.65 34,000 3.20 NONE — — 12.20 10.50 34,000 3.16 NONE — — 12.20 10.50 33,600 3.10 NONE — — 12.50 10.60 34,200 3.24 NONE — — 12.50 10.65 34,200 3.26 NONE — — 12.50 10.65 34,200 3.26 NONE — — 12.50 10.70 34,200 3.30 NONE — — 12.50 10.60 34,200 3.26 NONE — — 12.50 10.60 34,200 3.26 NONE — — 12.50 10.70 34,400 3.32 NONE — — 12.50 10.70 34,400 3.32 NONE — — 12.50 10.70 34,400 3.32 NONE — — 12.50 10.60 34,200 3.26 NONE — — 12.50 10.70 34,400 3.32 TDR&TXV 13.00 — — 11.00 40,500 3.36 TDR — 12.00 — 10.25 41,500 3.34 TDR — 12.00 — 10.25 41,500 3.38 TDR — 13.00 — 11.10 40,000 3.32 TDR — 13.50 — 11.55 40,000 3.56 TDR&TXV 14.00 — — 11.55 40,000 3.56 TDR&TXV 12.00 — — 10.25 41,500 3.40 NONE — — 12.00 10.35 41,500 3.32 NONE — — 12.00 10.30 41,500 3.34 NONE — — 12.00 10.30 41,500 3.34 NONE — — 12.00 10.30 41,500 3.34 NONE — — 12.00 10.30 41,500 3.34 TDR&TXV 13.50 — — 11.60 47,500 3.58 TDR — 11.70 — 10.20 48,500 3.32 TDR — 12.50 — 10.90 48,000 3.54 TDR — 11.70 — 10.20 48,000 3.32 TDR — 12.50 — 10.90 48,000 3.54 TDR — 13.20 — 11.60 48,000 3.58 TDR — 14.00 — 12.05 48,000 3.76 TDR&TXV 14.10 — — 12.05 48,000 3.76 TDR&TXV 12.50 — — 10.75 48,000 3.42 TDR&TXV 12.60 — — 10.90 48,000 3.54 NONE — — 12.50 10.80 48,000 3.40 See notes on page 9. —8— Heating Low-Temp TC 16,600 16,500 16,500 16,000 16,100 16,000 16,100 15,900 16,600 16,600 16,600 16,600 16,600 16,600 16,600 18,500 18,700 18,700 17,800 17,900 17,700 17,900 17,700 18,800 18,500 18,500 18,500 18,500 18,500 18,500 21,600 21,400 21,400 20,600 20,800 20,600 20,800 21,400 21,400 21,400 21,400 21,400 21,600 21,600 21,600 21,600 21,600 21,600 21,600 21,600 21,600 25,400 26,600 26,600 25,400 25,200 25,200 26,600 26,400 26,400 26,400 26,400 26,400 27,600 29,000 28,600 29,000 28,600 27,800 27,600 27,600 28,400 28,600 28,400 COP 2.38 2.32 2.32 2.42 2.54 2.54 2.48 2.48 2.36 2.36 2.34 2.38 2.38 2.38 2.38 2.38 2.32 2.32 2.44 2.48 2.50 2.48 2.52 2.36 2.38 2.38 2.36 2.38 2.40 2.40 2.34 2.28 2.28 2.40 2.52 2.40 2.52 2.26 2.24 2.22 2.28 2.28 2.28 2.30 2.28 2.28 2.30 2.30 2.30 2.28 2.30 2.46 2.42 2.42 2.44 2.56 2.56 2.42 2.40 2.40 2.40 2.40 2.40 2.46 2.26 2.38 2.26 2.38 2.46 2.54 2.54 2.34 2.38 2.34 HSPF 8.00 7.50 7.50 7.75 8.00 8.00 8.00 8.00 7.50 7.50 7.40 7.50 7.50 7.50 7.50 8.00 7.40 7.40 7.80 8.00 8.00 8.10 8.10 8.00 7.65 7.65 7.45 7.65 7.70 7.70 7.70 7.40 7.40 7.70 8.00 7.80 8.10 7.30 7.30 7.30 7.30 7.30 7.40 7.45 7.40 7.40 7.50 7.50 7.50 7.40 7.50 7.70 7.50 7.55 7.40 8.00 8.10 7.55 7.40 7.50 7.50 7.50 7.50 8.50 7.80 8.00 7.70 8.00 8.20 8.50 8.60 8.00 8.10 8.00 COMBINATION RATINGS Continued UNIT SIZESERIES 048-A,C 060-B,C INDOOR UNIT CJ5A/CK5A/CK5BA060 CJ5A/CK5A/CK5BN060 CJ5A/CK5A/CK5BX060 CK3BA060 FV4ANB006† FB4ANB070 FC4BNB070 FK4CNB006 FX4ANB060 CC5A/CD5AW060 CJ5A/CK5A/CK5BX060 CFM†† 1400 1400 1400 1400 1750 1750 1750 1750 1750 1750 1750 TC 45,000 45,500 45,500 45,000 58,000 57,000 57,000 58,000 57,000 56,000 56,500 ARI STANDARD RATINGS* Cooling Seasonal Efficiency SEER Field-Supplied High-Temp FactoryAccessory‡ Supplied Enhance- Standard Puron Puron TXV TXV & TDR** EER TC COP ment Rating NONE — — 12.50 10.75 48,000 3.50 NONE — — 13.00 10.90 48,500 3.52 NONE — — 13.00 10.90 48,500 3.52 NONE — — 12.50 10.75 48,000 3.50 TDR&TXV 13.00 — — 10.75 60,000 3.56 TDR — 12.00 — 10.20 60,000 3.44 TDR — 12.00 — 10.20 60,000 3.44 TDR — 12.80 — 10.75 59,500 3.56 TDR&TXV 12.00 — — 10.20 60,000 3.44 NONE — — 12.50 10.45 58,500 3.26 NONE — — 12.50 10.55 59,000 3.44 Heating Low-Temp TC 28,600 28,600 28,600 28,600 37,000 37,800 37,800 37,000 37,800 36,800 37,000 COP 2.38 2.38 2.38 2.38 2.54 2.46 2.46 2.54 2.46 2.42 2.50 HSPF 8.20 8.25 8.25 8.20 8.00 7.80 7.80 8.00 7.80 7.50 7.70 * Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit. High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit. Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit. † Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps. ‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type. ** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD. †† Indoor Airflow COP — Coefficient of Performance EER — Energy Efficiency Ratio HSPF — Heating Seasonal Performance Factor SEER — Seasonal Energy Efficiency Ratio TC — Total Capacity (Btuh) TDR — Time-Delay Relay TXV — Thermostatic Expansion Valve —9— 650A BALANCE POINT WORKSHEET 8.8 11.7 14.7 17.6 23.4 650AN060-B,C FV4A006 650AN048-A,C FV4A005 650AN042-A,C FV4A003 650AN036-A,C FX4A042 650AN030-A,C FX4A030 650AN024-A,C FX4A030 80 80 60 50 40 30 50 BASED ON INDOOR ENT. AIR AT 70˚F AND AT RATED CFM 60 70 5.9 40 20 30 2.9 20 10 10 20.5 0 A99002 —10— 70 -10 OUTDOOR TEMPERATURE, ˚F KW NOTE: The performance shown includes the PressureGuard™ cycling the outdoor fan. The ambient temperature that the outdoor fan cycles depends on the outdoor/indoor combination, indoor airflow, installation practices, and system maintenance, all of which affect system performance. BUILDING HEAT LOSS, 1000 BTU/HR UNIT INTEGRATED HEATING CAPACITY, 1000 BTU/HR DETAILED COOLING CAPACITIES* EVAP AIR CFM EWB 75 Capacity Total MBtuh† Sys Total Sens‡ Kw** CONDENSER ENTERING AIR TEMPERATURES °F 85 95 105 115 Capacity Capacity Capacity Capacity Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 125 Capacity Total MBtuh† Sys Total Sens‡ Kw** 650AN024-A,C , Outdoor Section With FX4ANF030 Indoor Section 700 800 900 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 29.7 27.2 25.3 24.8 23.7 30.3 27.7 25.8 25.4 24.7 30.8 28.2 26.2 25.9 25.5 Indoor Section FX4ANF 14.5 18.2 17.7 21.7 23.7 15.2 19.3 18.8 23.3 24.7 15.8 20.4 19.8 24.7 25.5 1.85 1.85 1.85 1.84 1.84 1.88 1.88 1.88 1.88 1.88 1.92 1.92 1.92 1.92 1.91 Size 030 28.4 14.0 2.07 26.9 13.5 2.31 25.4 12.9 2.57 23.8 25.9 17.6 2.06 24.6 17.1 2.30 23.2 16.5 2.55 21.7 24.1 17.2 2.06 22.9 16.6 2.29 21.6 16.1 2.54 20.2 23.7 21.2 2.06 22.5 20.6 2.29 21.3 20.0 2.54 20.0 22.8 22.8 2.06 21.9 21.9 2.29 20.9 20.9 2.54 19.8 28.9 14.6 2.11 27.3 14.1 2.35 25.8 13.6 2.61 24.1 26.4 18.7 2.10 25.0 18.2 2.34 23.6 17.6 2.59 22.0 24.6 18.2 2.10 23.3 17.7 2.33 21.9 17.1 2.58 20.5 24.2 22.7 2.10 23.0 22.1 2.33 21.8 21.4 2.58 20.5 23.7 23.7 2.10 22.7 22.7 2.33 21.6 21.6 2.58 20.5 29.3 15.3 2.14 27.7 14.7 2.38 26.1 14.2 2.64 24.3 26.8 19.8 2.14 25.3 19.3 2.37 23.9 18.7 2.63 22.3 24.9 19.2 2.13 23.6 18.6 2.37 22.2 18.1 2.62 20.8 24.7 24.1 2.13 23.5 23.3 2.37 22.3 22.3 2.62 21.1 24.5 24.5 2.13 23.4 23.4 2.37 22.3 22.3 2.62 21.1 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Capacity Power Section Size 1.00 1.00 CE3AA 030 F(A,B)4AN(F,C) 030 0.94 1.00 FC4BNF 030 0.96 1.00 FK4CNF FV4ANF CJ5A/CK5A/CK5BA 12.3 15.9 15.5 19.4 19.8 13.0 17.0 16.5 20.5 20.5 13.6 18.1 17.4 21.1 21.1 2.85 2.83 2.82 2.81 2.81 2.88 2.87 2.85 2.85 2.85 2.92 2.90 2.89 2.89 2.89 22.0 20.1 18.7 18.6 18.6 22.2 20.4 19.0 19.2 19.2 22.4 20.5 19.1 19.7 19.7 11.7 15.3 14.8 18.5 18.6 12.3 16.4 15.8 19.2 19.2 12.9 17.4 16.7 19.7 19.7 Cooling Capacity 0.94 Power 1.00 036 0.95 1.00 030 0.94 1.00 001 0.98 0.93 036 0.97 1.00 002 1.01 0.93 CJ5A/CK5A/CK5BN 036 0.97 1.00 003 1.01 0.91 CJ5A/CK5A/CK5BW 030 0.94 1.00 002 1.01 0.93 036 0.97 1.00 003 1.01 0.91 — — — CK3BA See notes on page 14. —11— 030 0.94 1.00 036 0.97 1.00 3.14 3.12 3.11 3.11 3.11 3.18 3.16 3.15 3.15 3.15 3.22 3.20 3.19 3.19 3.19 DETAILED COOLING CAPACITIES* Continued EVAP AIR CFM EWB 75 Capacity Total MBtuh† Sys Total Sens‡ Kw** CONDENSER ENTERING AIR TEMPERATURES °F 85 95 105 115 Capacity Capacity Capacity Capacity Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 125 Capacity Total MBtuh† Sys Total Sens‡ Kw** 650AN030-A,C Outdoor Section With FX4ANF030 Indoor Section 1825 1050 1250 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 34.3 31.4 29.2 28.8 27.8 35.2 32.4 30.2 29.9 29.8 35.8 32.9 30.7 31.0 31.0 17.2 21.7 21.1 26.2 27.8 18.7 24.3 23.6 29.4 29.8 20.0 26.5 25.6 31.0 31.0 2.07 2.06 2.04 2.04 2.04 2.14 2.13 2.11 2.11 2.11 2.20 2.19 2.17 2.17 2.17 32.6 16.6 2.31 30.9 15.9 2.58 29.0 15.3 2.87 27.0 29.9 21.1 2.29 28.3 20.5 2.56 26.6 19.8 2.86 24.8 27.8 20.5 2.28 26.4 19.9 2.55 24.8 19.2 2.84 23.1 27.4 25.5 2.28 26.0 24.8 2.55 24.5 24.0 2.84 23.0 26.7 26.7 2.27 25.6 25.6 2.54 24.3 24.3 2.84 23.0 33.5 18.1 2.38 31.6 17.4 2.65 29.7 16.8 2.94 27.6 30.7 23.7 2.36 29.0 23.0 2.63 27.2 22.3 2.93 25.3 28.6 22.9 2.35 27.0 22.3 2.62 25.4 21.5 2.91 23.6 28.6 28.5 2.35 27.2 27.2 2.62 25.8 25.8 2.91 24.3 28.5 28.5 2.35 27.2 27.2 2.62 25.8 25.8 2.91 24.3 34.0 19.4 2.44 32.1 18.7 2.71 30.0 18.1 3.00 27.8 31.2 25.8 2.42 29.4 25.1 2.69 27.6 24.4 2.98 25.6 29.1 24.9 2.41 27.5 24.2 2.67 25.7 23.4 2.97 23.9 29.7 29.7 2.41 28.3 28.3 2.68 26.8 26.8 2.98 25.1 29.7 29.7 2.41 28.3 28.3 2.68 26.8 26.8 2.98 25.1 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Section FX4ANF Size 030 F(A,B)4AN(F,C) FC4BNF FK4CNF Capacity 1.00 Power 1.00 14.6 19.1 18.5 23.0 23.0 16.1 21.6 20.8 24.3 24.3 17.3 23.6 22.6 25.1 25.1 3.20 3.18 3.17 3.17 3.17 3.27 3.25 3.24 3.24 3.24 3.33 3.31 3.30 3.31 3.31 24.8 22.7 21.2 21.4 21.4 25.2 23.2 21.6 22.5 22.6 25.4 23.4 21.9 23.2 23.2 13.8 18.3 17.7 21.4 21.4 15.3 20.7 19.9 22.5 22.6 16.5 22.6 21.5 23.2 23.2 3.56 3.54 3.53 3.53 3.53 3.62 3.61 3.59 3.60 3.60 3.68 3.67 3.65 3.67 3.67 Cooling Indoor Section FV4ANF Size 002 003 1.01 0.90 FX4ANF 036 1.00 1.03 Capacity 1.01 Power 0.93 030 0.97 1.00 036 0.98 1.03 030 0.97 1.00 CE3AA 036 0.99 1.00 036 0.98 1.03 CJ5A/CK5A/CK5BN 036 0.99 1.00 001 0.99 0.92 CJ5A/CK5A/CK5BW 036 0.99 1.00 002 0.99 0.93 CK3BA 036 0.99 1.00 003 1.00 0.90 — — — 650AN036-A,C Outdoor Section With FX4ANF042 Indoor Section 1125 1250 1375 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 42.3 38.7 36.1 35.5 34.7 42.7 39.2 36.6 36.1 35.7 43.1 39.6 36.9 36.7 36.6 21.3 27.3 26.5 33.0 34.7 22.1 28.6 27.8 34.8 35.7 22.8 30.0 29.0 36.4 36.6 2.64 2.63 2.63 2.63 2.63 2.69 2.68 2.68 2.68 2.68 2.74 2.73 2.73 2.73 2.73 40.3 20.6 2.93 38.3 19.8 3.26 36.0 19.1 3.61 33.7 36.9 26.5 2.93 35.0 25.8 3.25 33.0 25.0 3.60 30.8 34.4 25.7 2.92 32.6 25.0 3.24 30.6 24.1 3.59 28.6 33.9 32.2 2.92 32.2 31.4 3.24 30.4 30.3 3.59 28.7 33.3 33.3 2.92 31.9 31.9 3.24 30.4 30.4 3.59 28.7 40.7 21.4 2.98 38.6 20.6 3.31 36.3 19.9 3.66 33.9 37.3 27.9 2.98 35.4 27.1 3.30 33.2 26.3 3.65 31.0 34.8 27.0 2.97 32.9 26.2 3.29 31.0 25.4 3.64 28.8 34.5 33.9 2.97 32.8 32.8 3.29 31.2 31.2 3.64 29.4 34.3 34.3 2.97 32.8 32.8 3.29 31.2 31.2 3.64 29.4 41.1 22.1 3.03 38.9 21.4 3.36 36.6 20.6 3.71 34.1 37.7 29.2 3.03 35.6 28.4 3.35 33.5 27.6 3.70 31.3 35.1 28.2 3.02 33.2 27.4 3.34 31.2 26.6 3.69 29.0 35.1 35.1 3.02 33.5 33.5 3.34 31.8 31.8 3.69 30.0 35.1 35.1 3.02 33.5 33.5 3.34 31.8 31.8 3.69 30.0 Multipliers for Determining the Performance With Other Indoor Sections Cooling 18.3 24.1 23.3 28.7 28.7 19.0 25.4 24.5 29.4 29.4 19.8 26.7 25.7 30.0 30.0 4.00 3.98 3.96 3.96 3.96 4.05 4.03 4.01 4.02 4.02 4.10 4.08 4.06 4.07 4.07 31.0 28.3 26.3 26.8 26.8 31.2 28.5 26.5 27.4 27.4 31.3 28.7 26.7 28.0 27.9 17.4 23.2 22.3 26.8 26.8 18.1 24.5 23.5 27.4 27.4 18.9 25.7 24.6 28.0 27.9 Cooling Indoor Section Size Capacity Power Indoor Section Size Capacity Power FX4ANF 042 1.00 1.00 CE3AA 042 0.97 1.00 F(A,B)4AN(F,B,C) 042 0.96 1.00 048 0.98 1.00 FC4BN(F,B) 042 0.96 1.00 042 0.97 1.00 FK4CNF 003 0.97 0.91 048 0.98 1.00 005 1.01 0.91 003 0.98 0.91 005 1.02 0.91 CJ5A/CK5A/CK5BW 048 0.98 1.00 042 0.99 1.00 CK3BA 042 0.97 1.00 — — 048 0.98 1.00 FV4ANF CC5A/CD5AA — CJ5A/CK5A/CK5BA CJ5A/CK5A/CK5BN See notes on page 14. —12— 042 0.97 1.00 048 0.98 1.00 4.40 4.38 4.36 4.37 4.37 4.46 4.43 4.41 4.42 4.42 4.51 4.48 4.46 4.48 4.48 DETAILED COOLING CAPACITIES* Continued EVAP AIR CFM EWB 75 Capacity Total MBtuh† Sys Total Sens‡ Kw** CONDENSER ENTERING AIR TEMPERATURES °F 85 95 105 115 Capacity Capacity Capacity Capacity Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 125 Capacity Total MBtuh† Sys Total Sens‡ Kw** 650AN042-A,C Outdoor Section With FV4ANF003 Indoor Section 1225 1400 1575 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 48.5 44.6 41.7 41.0 39.7 49.4 45.4 42.5 41.9 41.2 50.0 46.0 43.1 42.7 42.4 24.4 30.9 30.1 37.2 39.7 25.6 32.9 32.0 39.7 41.2 26.7 34.7 33.7 41.9 42.4 2.95 2.91 2.89 2.88 2.87 2.99 2.96 2.93 2.93 2.92 3.04 3.00 2.98 2.97 2.97 46.4 23.6 3.32 44.1 22.8 3.72 41.7 21.9 4.17 39.0 42.6 30.1 3.28 40.5 29.2 3.68 38.3 28.3 4.12 35.8 39.8 29.3 3.25 37.8 28.4 3.65 35.7 27.5 4.09 33.4 39.2 36.3 3.24 37.3 35.3 3.65 35.3 34.3 4.09 33.2 38.2 38.2 3.24 36.7 36.7 3.64 35.0 35.0 4.08 33.1 47.1 24.8 3.36 44.8 23.9 3.77 42.2 23.1 4.22 39.5 43.3 32.0 3.32 41.2 31.2 3.73 38.8 30.2 4.17 36.3 40.5 31.1 3.30 38.4 30.2 3.70 36.2 29.3 4.14 33.9 40.0 38.7 3.29 38.2 37.6 3.70 36.2 36.2 4.14 34.2 39.6 39.6 3.29 37.9 37.9 3.69 36.1 36.1 4.14 34.2 47.7 25.9 3.41 45.3 25.1 3.81 42.7 24.2 4.26 39.9 43.9 33.9 3.37 41.6 33.0 3.77 39.3 32.1 4.22 36.7 41.0 32.8 3.34 38.9 31.9 3.74 36.7 31.0 4.19 34.3 40.9 40.7 3.34 39.0 39.0 3.74 37.1 37.1 4.19 35.1 40.8 40.8 3.34 39.0 39.0 3.74 37.1 37.1 4.19 35.1 Multipliers for Determining the Performance With Other Indoor Sections Cooling 21.0 27.4 26.5 33.0 33.1 22.1 29.3 28.3 34.2 34.2 23.2 31.1 29.9 35.1 35.1 4.65 4.61 4.57 4.57 4.57 4.70 4.65 4.62 4.62 4.62 4.74 4.70 4.66 4.68 4.68 36.1 33.2 31.0 31.1 31.1 36.5 33.6 31.3 32.0 32.0 36.8 33.9 31.6 32.8 32.8 20.0 26.3 25.5 31.1 31.1 21.1 28.2 27.2 32.0 32.0 22.2 29.9 28.8 32.8 32.8 5.17 5.12 5.09 5.09 5.09 5.22 5.17 5.14 5.15 5.15 5.26 5.22 5.18 5.20 5.20 Cooling Indoor Section Size Capacity Power Indoor Section Size Capacity Power FV4ANF 003 1.00 1.00 CE3AA 048 1.00 1.08 F(A,B)4AN(F,B,C) 048 0.99 1.07 CJ5A/CK5A/CK5BA 048 0.99 1.08 FC4BN(F,B) 048 1.00 1.09 CJ5A/CK5A/CK5BN 048 0.99 1.08 FK4CNF 003 1.00 1.00 CJ5A/CK5A/CK5BW 048 0.99 1.08 005 1.01 0.98 CK3BA 048 0.99 1.08 FV4ANF 005 1.01 0.98 — — — FX4ANF 042 1.00 1.09 650AN048-A,C Outdoor Section With FV4ANF005 Indoor Section 1400 1600 1800 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 54.7 50.2 46.8 46.1 44.9 55.6 51.1 47.7 47.1 46.7 56.3 51.7 48.3 48.2 48.1 Indoor Section FV4ANF 27.7 35.2 34.3 42.5 44.9 29.1 37.5 36.5 45.5 46.7 30.4 39.7 38.5 48.1 48.1 3.20 3.16 3.13 3.12 3.11 3.26 3.22 3.19 3.18 3.18 3.32 3.28 3.24 3.24 3.24 52.2 26.8 3.56 49.6 25.9 3.96 46.9 24.9 4.41 43.9 47.9 34.3 3.52 45.5 33.3 3.92 43.0 32.3 4.36 40.3 44.7 33.3 3.49 42.4 32.4 3.89 40.1 31.3 4.33 37.6 44.0 41.5 3.48 42.0 40.5 3.88 39.7 39.3 4.33 37.5 43.2 43.2 3.47 41.4 41.4 3.88 39.6 39.6 4.33 37.5 53.0 28.1 3.62 50.3 27.2 4.02 47.4 26.2 4.47 44.4 48.7 36.6 3.58 46.2 35.6 3.98 43.6 34.6 4.42 40.8 45.4 35.5 3.55 43.1 34.5 3.95 40.7 33.5 4.39 38.1 45.1 44.4 3.54 42.9 42.9 3.95 41.0 41.0 4.39 38.8 44.8 44.8 3.54 42.9 42.9 3.94 40.9 40.9 4.39 38.8 53.6 29.4 3.68 50.8 28.5 4.08 47.9 27.5 4.53 44.8 49.3 38.8 3.64 46.7 37.8 4.04 44.1 36.8 4.48 41.2 46.0 37.5 3.60 43.6 36.5 4.00 41.1 35.5 4.45 38.5 46.2 46.2 3.61 44.2 44.2 4.01 42.1 42.1 4.46 39.8 46.2 46.2 3.60 44.2 44.2 4.01 42.1 42.1 4.46 39.8 Multipliers for Determining the Performance With Other Indoor Sections Cooling Size 005 Capacity 1.00 Power 1.00 Indoor Section FX4ANF 23.9 31.3 30.3 37.5 37.5 25.2 33.5 32.4 38.8 38.8 26.5 35.7 34.4 39.8 39.8 4.90 4.85 4.82 4.82 4.82 4.96 4.91 4.88 4.89 4.89 5.01 4.97 4.94 4.95 4.95 40.7 37.4 34.9 35.2 35.2 41.1 37.8 35.3 36.3 36.4 41.4 38.2 35.7 37.3 37.3 22.8 30.1 29.1 35.2 35.2 24.1 32.3 31.2 36.3 36.4 25.4 34.4 33.1 37.3 37.3 Cooling Size 048 Capacity 0.99 Power 1.06 F(A,B)4AN(F,B,C) 060 0.98 1.10 FX4ANB 060 1.00 1.06 FB4ANB 070 1.01 1.06 CE3AA 060 1.00 1.06 FC4BN(F,B) 060 0.98 1.10 CJ5A/CK5A/CK5BA 060 0.99 1.06 FC4BNB 070 1.01 1.06 CJ5A/CK5A/CK5BN 060 1.00 1.06 FK4CNB 006 1.02 0.98 CJ5A/CK5A/CK5BX 060 1.00 1.06 FK4CNF 005 1.00 1.00 CK3BA 060 0.99 1.06 FV4ANB 006 1.02 0.98 — — — See notes on page 14. —13— 5.43 5.39 5.36 5.37 5.37 5.49 5.45 5.42 5.43 5.43 5.55 5.51 5.48 5.50 5.50 DETAILED COOLING CAPACITIES* Continued EVAP AIR CFM EWB 75 Capacity Total MBtuh† Sys Total Sens‡ Kw** CONDENSER ENTERING AIR TEMPERATURES °F 85 95 105 115 Capacity Capacity Capacity Capacity Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 125 Capacity Total MBtuh† Sys Total Sens‡ Kw** 650AN060-B,C Outdoor Section With FV4ANB006 Indoor Section 1750 2000 2250 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 70.1 64.4 60.2 59.2 57.8 71.1 65.5 61.2 60.5 60.1 72.0 66.2 61.9 61.8 61.8 35.6 45.5 44.3 55.1 57.8 37.4 48.5 47.1 59.0 60.1 39.1 51.4 49.8 61.8 61.8 4.43 4.35 4.30 4.29 4.27 4.52 4.44 4.39 4.38 4.38 4.61 4.53 4.48 4.48 4.48 66.6 34.4 4.92 63.1 33.1 5.47 59.2 31.7 6.07 55.0 61.3 44.2 4.85 58.0 42.9 5.40 54.5 41.5 6.00 50.6 57.2 43.0 4.79 54.2 41.7 5.34 50.9 40.3 5.94 47.3 56.4 53.7 4.78 53.5 52.3 5.33 50.5 50.4 5.93 47.5 55.6 55.6 4.77 53.1 53.1 5.32 50.5 50.5 5.93 47.5 67.6 36.1 5.02 63.9 34.8 5.57 59.8 33.4 6.16 55.5 62.2 47.2 4.94 58.8 45.9 5.49 55.1 44.4 6.09 51.1 58.1 45.8 4.88 54.9 44.4 5.43 51.6 43.0 6.03 47.9 57.7 57.4 4.88 54.9 54.9 5.43 52.1 52.1 6.04 48.9 57.6 57.6 4.88 54.9 54.9 5.43 52.1 52.1 6.04 49.0 68.3 37.8 5.10 64.4 36.5 5.65 60.4 35.1 6.25 55.9 62.9 50.1 5.03 59.4 48.7 5.57 55.6 47.3 6.17 51.7 58.8 48.5 4.97 55.6 47.1 5.52 52.1 45.6 6.12 48.3 59.2 59.2 4.98 56.5 56.5 5.53 53.5 53.5 6.14 50.2 59.2 59.2 4.98 56.4 56.4 5.53 53.4 53.4 6.14 50.2 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Section FV4ANB Size 006 Capacity 1.00 Power 1.00 30.3 40.0 38.8 47.5 47.5 32.0 42.9 41.5 48.9 49.0 33.7 45.7 44.0 50.2 50.2 6.73 6.65 6.60 6.60 6.60 6.81 6.74 6.68 6.70 6.70 6.90 6.83 6.77 6.80 6.80 50.2 46.4 43.4 44.2 44.2 50.6 46.8 43.8 45.3 45.4 50.8 47.1 44.1 46.4 46.4 28.7 38.4 37.1 44.2 44.2 30.4 41.2 39.7 45.3 45.4 32.0 43.9 42.1 46.4 46.4 7.42 7.35 7.30 7.32 7.32 7.51 7.44 7.39 7.42 7.42 7.59 7.53 7.48 7.51 7.51 Cooling Indoor Section FX4ANB Size 060 Capacity 0.98 Power 1.04 FB4ANB 070 0.98 1.04 CC5A/CD5AW 060 0.97 0.99 FC4BNB 070 0.98 1.04 CJ5A/CK5A/CK5BX 060 0.97 1.00 FK4CNB 006 1.00 1.00 — — — * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. † Total and sensible capacities are net capacities. Blower motor heat has been subtracted. ‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80°F (27°C). ** System kw is total of indoor and outdoor unit kilowatts. †† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb. EWB—Entering Wet Bulb —14— HEAT PUMP HEATING PERFORMANCE OUTDOOR COIL ENTERING AIR TEMPERATURES °F –3 7 17 27 37 47 57 67 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr CFM Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† INDOOR AIR EDB 650AN024-A,C Outdoor Section With FX4ANF030 Indoor Section 65 70 75 700 800 900 700 800 900 700 800 900 12.0 12.2 12.4 11.8 12.0 12.1 11.5 11.7 11.8 11.1 11.2 11.4 10.8 11.0 11.2 10.6 10.7 10.9 1.79 1.80 1.82 1.87 1.88 1.90 1.96 1.97 1.98 14.3 14.5 14.6 14.1 14.3 14.4 13.9 14.1 14.3 13.1 1.87 16.6 15.1 1.95 19.0 16.9 2.04 21.9 19.9 2.16 25.0 25.0 13.3 1.87 16.8 15.3 1.95 19.2 17.1 2.03 22.1 20.1 2.13 25.4 25.4 13.4 1.88 17.0 15.5 1.95 19.4 17.3 2.03 22.4 20.4 2.13 25.6 25.6 13.0 1.96 16.4 15.0 2.05 18.8 16.7 2.14 21.6 19.6 2.26 24.7 24.7 13.1 1.96 16.6 15.1 2.04 19.0 16.9 2.13 21.8 19.9 2.24 25.0 25.0 13.3 1.97 16.8 15.3 2.05 19.2 17.0 2.13 22.1 20.1 2.23 25.3 25.3 12.8 2.05 16.2 14.8 2.15 18.5 16.5 2.25 21.3 19.4 2.38 24.3 24.3 13.0 2.06 16.4 15.0 2.14 18.8 16.7 2.23 21.5 19.6 2.35 24.6 24.6 13.1 2.07 16.6 15.1 2.15 19.0 16.8 2.23 21.8 19.8 2.34 24.9 24.9 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Section FX4ANF Size 030 Capacity 1.00 Power 1.00 2.30 2.27 2.25 2.41 2.38 2.36 2.53 2.50 2.48 28.5 28.9 29.3 28.1 28.5 28.8 27.7 28.1 28.4 28.5 28.9 29.3 28.1 28.5 28.8 27.7 28.1 28.4 2.48 2.44 2.43 2.60 2.56 2.54 2.73 2.68 2.66 32.6 33.1 33.4 32.0 32.5 32.9 31.5 32.0 32.4 32.6 33.1 33.4 32.0 32.5 32.9 31.5 32.0 32.4 Cooling Indoor Section CE3AA Size 030 036 0.98 1.01 CJ5A/CK5A/CK5BA 030 0.98 1.01 Capacity 0.98 Power 1.01 F(A,B)4AN(F,C) 030 0.98 1.01 FC4BNF 030 0.98 1.01 FK4CNF 001 0.95 0.95 036 0.99 0.98 002 1.00 0.92 CJ5A/CK5A/CK5BN 036 0.99 0.98 003 1.01 0.94 CJ5A/CK5A/CK5BW 030 0.98 1.01 002 1.01 0.97 036 0.99 0.98 003 1.00 0.96 — — FV4ANF — CK3BA 2.74 2.69 2.67 2.87 2.81 2.79 3.00 2.94 2.91 030 0.98 1.01 036 0.99 0.98 650AN030-A,C Outdoor Section With FX4ANF030 Indoor Section 65 70 75 825 1050 1250 825 1050 1250 825 1050 1250 12.6 12.9 13.2 12.3 12.7 13.0 12.0 12.4 12.7 11.6 11.9 12.2 11.3 11.7 11.9 11.1 11.4 11.7 Indoor Section FX4ANF F(A,B)4AN(F,C) FC4BNF FK4CNF 2.07 2.11 2.15 2.18 2.21 2.25 2.29 2.32 2.36 15.4 15.7 16.0 15.2 15.6 15.8 15.0 15.3 15.6 14.1 2.12 18.3 16.7 2.16 21.6 19.2 2.22 25.4 23.1 2.29 29.7 29.7 14.4 2.14 18.7 17.0 2.17 22.0 19.6 2.21 25.9 23.6 2.27 30.4 30.4 14.7 2.17 19.0 17.3 2.19 22.4 19.9 2.23 26.3 23.9 2.28 30.8 30.8 14.0 2.23 18.1 16.5 2.28 21.4 19.0 2.33 25.1 22.8 2.41 29.4 29.4 14.3 2.25 18.5 16.9 2.28 21.8 19.4 2.32 25.6 23.3 2.38 30.0 30.0 14.5 2.28 18.8 17.1 2.30 22.1 19.6 2.34 26.0 23.6 2.39 30.4 30.4 13.7 2.34 18.0 16.4 2.40 21.1 18.8 2.46 24.8 22.6 2.54 29.0 29.0 14.1 2.35 18.3 16.7 2.40 21.6 19.1 2.44 25.3 23.0 2.50 29.6 29.6 14.4 2.39 18.6 17.0 2.42 21.9 19.4 2.45 25.7 23.4 2.51 30.0 30.0 Multipliers for Determining the Performance With Other Indoor Sections Cooling Size 030 Capacity 1.00 Power 1.00 2.39 2.35 2.36 2.52 2.47 2.47 2.65 2.59 2.59 34.6 35.4 36.0 34.1 34.9 35.4 33.7 34.4 34.9 34.6 35.4 36.0 34.1 34.9 35.4 33.7 34.4 34.9 2.69 2.63 2.64 2.82 2.76 2.76 2.96 2.89 2.89 32.7 33.5 33.9 32.2 33.0 33.4 31.7 32.5 33.0 32.7 33.5 33.9 32.2 33.0 33.4 31.7 32.5 33.0 Cooling Indoor Section FV4ANF Size 002 003 0.95 0.92 FX4ANF 036 1.00 1.01 Capacity 0.97 Power 0.94 030 0.98 1.02 036 0.99 1.03 030 0.98 1.02 CE3AA 036 0.97 1.01 036 0.99 1.03 CJ5A/CK5A/CK5BN 036 0.98 0.99 001 0.95 0.96 CJ5A/CK5A/CK5BW 036 0.98 0.98 002 0.97 0.94 CK3BA 036 0.98 0.98 003 0.95 0.92 — — — See notes on page 17. —15— 2.55 2.49 2.49 2.67 2.60 2.60 2.80 2.72 2.71 HEAT PUMP HEATING PERFORMANCE Continued OUTDOOR COIL ENTERING AIR TEMPERATURES °F –3 7 17 27 37 47 57 67 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr CFM Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† INDOOR AIR EDB 650AN036-A,C Outdoor Section With FX4ANF042 Indoor Section 65 70 75 1125 1250 1375 1125 1250 1375 1125 1250 1375 14.7 14.9 15.1 14.1 14.4 14.6 13.5 13.8 14.0 13.5 13.7 13.9 13.0 13.2 13.4 12.4 12.7 12.9 2.42 2.45 2.49 2.51 2.54 2.58 2.60 2.63 2.67 18.3 18.5 18.7 17.9 18.1 18.4 17.4 17.7 17.9 16.8 2.51 21.9 20.0 2.59 25.8 22.9 2.66 30.4 27.6 2.76 35.6 35.6 17.0 2.53 22.9 20.9 2.61 26.1 23.2 2.67 30.7 27.9 2.76 35.9 35.9 17.2 2.56 22.4 20.4 2.62 26.3 23.4 2.68 31.0 28.2 2.76 36.3 36.3 16.4 2.61 21.6 19.7 2.70 25.4 22.6 2.79 29.9 27.2 2.89 35.0 35.0 16.7 2.63 21.9 19.9 2.72 25.7 22.8 2.79 30.2 27.5 2.89 35.4 35.4 16.9 2.66 22.1 20.1 2.74 26.0 23.1 2.81 30.5 27.8 2.89 35.7 35.7 16.0 2.71 21.2 19.4 2.82 25.0 22.2 2.92 29.5 26.8 3.03 34.5 34.5 16.2 2.74 21.5 19.6 2.84 25.3 22.5 2.92 29.8 27.1 3.02 34.8 34.8 16.4 2.76 21.7 19.8 2.86 25.6 22.7 2.93 30.1 27.4 3.03 35.2 35.2 Multipliers for Determining the Performance With Other Indoor Sections Cooling 41.7 42.1 42.5 41.5 41.5 41.8 40.3 40.8 41.2 41.7 42.1 42.5 41.5 41.5 41.8 40.3 40.8 41.2 3.04 3.03 3.03 3.19 3.17 3.16 3.34 3.31 3.31 48.8 49.3 49.7 48.0 48.5 48.9 47.1 47.7 48.1 48.8 49.3 49.7 48.0 48.5 48.9 47.1 47.7 48.1 Size 042 Capacity 1.00 Power 1.00 F(A,B)4AN(F,B,C) 042 0.98 1.02 FC4BN(F,B) 042 0.98 1.02 FK4CNF 003 0.96 0.96 005 0.97 0.89 CJ5A/CK5A/CK5BW 048 0.98 1.01 003 0.96 0.95 CK3BA 042 0.98 1.02 005 0.97 0.89 048 0.98 1.01 042 0.98 1.02 — — — 048 0.98 1.01 CE3AA CJ5A/CK5A/CK5BN 3.27 3.25 3.25 3.42 3.40 3.39 3.58 3.55 3.54 Cooling Indoor Section FX4ANF FV4ANF Indoor Section CJ5A/CK5A/CK5BA 2.88 2.87 2.87 3.02 3.00 3.00 3.16 3.15 3.15 Size 042 Capacity 0.98 Power 1.02 048 0.98 1.01 042 0.98 1.02 048 0.98 1.01 650AN042-A,C Outdoor Section With FV4ANF003 Indoor Section 65 70 75 1225 1400 1575 1225 1400 1575 1225 1400 1575 17.3 17.6 17.8 16.8 17.1 17.3 16.3 16.6 16.8 15.9 16.2 16.4 15.5 15.7 15.9 15.0 15.2 15.4 2.61 2.61 2.62 2.74 2.75 2.76 2.88 2.89 2.90 21.5 22.5 21.9 21.1 21.4 21.6 20.6 20.9 21.2 19.8 2.74 25.7 23.4 2.86 30.0 26.6 2.99 35.1 32.0 3.14 41.1 41.1 20.7 2.74 25.9 23.6 2.84 30.2 26.9 2.95 35.5 32.3 3.09 41.5 41.5 20.2 2.73 26.1 23.8 2.83 30.5 27.1 2.93 35.8 32.6 3.06 41.9 41.9 19.4 2.88 25.4 23.2 3.03 29.6 26.3 3.16 34.7 31.6 3.32 40.5 40.5 19.6 2.87 25.6 23.4 3.00 29.9 26.6 3.12 35.0 31.9 3.27 41.0 41.0 19.8 2.87 25.8 23.6 2.99 30.1 26.8 3.10 35.3 32.2 3.24 41.3 41.3 19.0 3.02 25.1 22.9 3.19 29.3 26.0 3.34 34.3 31.2 3.51 40.0 40.0 19.2 3.01 25.3 23.1 3.17 29.6 26.3 3.30 34.6 31.5 3.46 40.4 40.4 19.4 3.01 25.5 23.3 3.16 29.8 26.5 3.28 34.9 31.8 3.42 40.8 40.8 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Section FV4ANF Size 003 Capacity 1.00 Power 1.00 F(A,B)4AN(F,B,C) 048 1.02 FC4BN(F,B) 048 1.02 FK4CNF 003 FV4ANF 3.34 3.28 3.24 3.53 3.46 3.42 3.73 3.66 3.61 40.4 40.8 41.2 39.8 40.2 40.6 39.2 39.6 40.0 40.4 40.8 41.2 39.8 40.2 40.6 39.2 39.6 40.0 3.30 3.22 3.18 3.48 3.40 3.35 3.66 3.58 3.53 39.5 40.0 40.4 38.9 39.4 39.8 38.3 38.8 39.1 39.5 40.0 40.4 38.9 39.4 39.8 38.3 38.8 39.1 Cooling Indoor Section FX4ANF Size 042 Capacity 1.02 Power 1.01 1.03 CE3AA 048 1.02 1.04 1.02 CJ5A/CK5A/CK5BA 048 1.02 1.03 0.99 1.00 CJ5A/CK5A/CK5BN 048 1.02 1.03 005 0.99 0.93 CJ5A/CK5A/CK5BW 048 1.02 1.03 005 0.99 0.93 CK3BA 048 1.02 1.03 See notes on page 17. —16— 3.21 3.14 3.09 3.38 3.30 3.25 3.56 3.47 3.41 HEAT PUMP HEATING PERFORMANCE Continued OUTDOOR COIL ENTERING AIR TEMPERATURES °F –3 7 17 27 37 47 57 67 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr CFM Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† INDOOR AIR EDB 650AN048-A,C Outdoor Section With FV4ANF005 Indoor Section 65 70 75 1400 1600 1800 1400 1600 1800 1400 1600 1800 18.5 18.7 18.9 18.1 18.4 18.6 17.7 18.0 18.2 17.0 17.2 17.4 16.7 16.9 17.1 16.3 16.6 16.8 2.86 2.87 2.89 3.03 3.03 3.05 3.19 3.20 3.22 22.9 23.2 23.4 22.7 23.0 23.2 22.4 22.7 22.9 21.1 2.99 27.9 25.4 3.11 33.5 29.8 3.26 40.2 36.6 3.45 48.2 48.2 21.3 2.98 28.1 25.6 3.10 33.8 30.1 3.23 40.7 37.0 3.41 48.7 48.7 21.5 2.99 28.4 25.9 3.10 34.1 30.3 3.23 41.0 37.3 3.40 49.1 49.1 20.9 3.16 27.6 25.2 3.29 33.2 29.4 3.44 39.8 36.2 3.64 47.5 47.5 21.1 3.15 27.8 25.4 3.27 33.5 29.7 3.41 40.2 36.5 3.60 48.0 48.0 21.3 3.16 28.1 25.6 3.27 33.8 30.0 3.41 40.5 36.9 3.58 48.4 48.4 20.6 3.33 27.4 24.9 3.48 32.8 29.2 3.64 39.3 35.7 3.84 46.8 46.8 20.9 3.33 27.6 25.2 3.46 33.1 29.4 3.60 39.7 36.1 3.79 47.4 47.4 21.1 3.33 27.8 25.4 3.45 33.4 29.7 3.59 40.0 36.4 3.77 47.8 47.8 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Section FV4ANF Size 005 Capacity 1.00 Power 1.00 Indoor Section FX4ANB 3.69 3.64 3.63 3.89 3.83 3.81 4.09 4.04 4.01 53.8 54.4 54.9 54.3 53.6 54.1 52.2 52.8 53.3 53.8 54.4 54.9 54.3 53.6 54.1 52.2 52.8 53.3 4.34 4.28 4.26 4.57 4.50 4.47 4.80 4.72 4.69 53.1 53.7 54.1 52.3 52.9 53.3 51.4 52.0 52.5 53.1 53.7 54.1 52.3 52.9 53.3 51.4 52.0 52.5 4.20 4.14 4.12 4.40 4.33 4.31 4.62 4.54 4.51 Cooling Size 060 Capacity 1.01 Power 1.02 F(A,B)4AN(F,B,C) 060 1.02 1.10 FX4ANF 048 1.01 1.06 FB4ANB 070 1.01 1.02 CE3AA 060 1.01 1.06 FC4BN(F,B) 060 1.01 1.09 CJ5A/CK5A/CK5BA 060 1.01 1.03 FC4BNB 070 1.01 1.02 CJ5A/CK5A/CK5BN 060 1.02 1.04 FK4CNB 006 1.01 0.96 CJ5A/CK5A/CK5BX 060 1.02 1.04 FK4CNF 005 1.01 1.01 CK3BA 060 1.01 1.03 FV4ANB 006 1.01 0.96 — — — 650AN060-B,C Outdoor Section With FV4ANB006 Indoor Section 65 70 75 1750 2000 2250 1750 2000 2250 1750 2000 2250 24.4 24.9 25.3 23.4 23.8 24.3 22.2 22.7 23.2 22.4 22.9 23.3 21.5 21.9 22.3 20.5 20.9 21.3 3.73 3.76 3.80 3.92 3.95 4.00 4.12 4.15 4.20 30.9 31.5 31.9 30.0 30.5 31.0 28.9 29.5 30.0 28.4 3.88 37.9 34.6 4.05 45.0 40.0 4.24 52.6 47.9 4.45 60.8 60.8 28.9 3.90 38.5 35.1 4.05 45.7 40.6 4.22 53.2 48.4 4.41 61.6 61.6 29.3 3.93 39.0 35.5 4.06 46.2 41.0 4.23 53.7 48.9 4.39 62.2 62.2 27.6 4.09 37.0 33.7 4.27 44.2 39.2 4.46 52.0 47.3 4.70 60.0 60.0 28.0 4.10 37.6 34.3 4.26 44.8 39.8 4.44 52.5 47.8 4.65 60.7 60.7 28.5 4.13 38.1 34.7 4.28 45.4 40.3 4.45 53.1 48.3 4.63 61.4 61.4 26.6 4.30 36.0 32.9 4.49 43.2 38.4 4.70 51.3 46.7 4.96 59.2 59.2 27.1 4.31 36.7 33.4 4.49 43.9 39.0 4.67 51.9 47.2 4.90 59.9 59.9 27.5 4.34 37.2 33.9 4.50 44.5 39.5 4.67 52.4 47.7 4.88 60.6 60.6 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Section FV4ANB Size 006 Capacity 1.00 Power 1.00 4.68 4.61 4.58 4.94 4.87 4.83 5.21 5.13 5.09 58.2 59.0 59.6 57.4 58.1 58.8 56.5 57.3 57.9 58.2 59.0 59.6 57.4 58.1 58.8 56.5 57.3 57.9 4.52 4.44 4.39 4.76 4.67 4.62 5.02 4.92 4.86 56.3 57.1 57.8 55.4 56.2 56.9 54.5 55.3 56.0 56.3 57.1 57.8 55.4 56.2 56.9 54.5 55.3 56.0 4.47 4.37 4.31 4.71 4.60 4.53 4.95 4.83 4.76 Cooling Indoor Section FX4ANB Size 060 Capacity 1.00 Power 1.03 FB4ANB 070 1.00 1.03 CC5A/CD5AW 060 0.98 1.06 FC4BNB 070 1.00 1.03 CJ5A/CK5A/CK5BX 060 0.98 1.02 FK4CNB 006 0.99 0.99 — – — * The Btuh heating capacity values shown are net “integrated” values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity. † The kw values include the compressor, outdoor fan motor, and indoor blower motor. The kw from supplement heaters should be added to these values to obtain total system kilowatts. EDB—Entering Dry Bulb NOTE: The performance shown includes the PressureGuard™ cycling the outdoor fan. The ambient temperature that the outdoor fan cycles depends on the outdoor/indoor combination, indoor airflow, installation practices, and system maintenance, all of which affect system performance. —17— System Design 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. Minimum outdoor operating air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C). Maximum outdoor operating air temperature for cooling mode is 125°F (51.7°C). Minimum outdoor operating air temperature for heating mode is –30°F (–34.4°C). Maximum outdoor operating air temperature for heating mode is 66°F (18.9°C). For reliable operation, unit should be level in all horizontal planes. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft. (See items 8 and 9 following). For interconnecting refrigerant tube lengths greater than 50 ft and/or elevation differences between indoor and outdoor units greater than 20 ft, consult Residential Split-System Application Guideline and Service Manual for Air Conditioners and Heat Pumps using Puron Refrigerant. If ANY refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36-in. may be buried without further considerations. Buried refrigerant tubing lengths greater than 36 in. are not recommended. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. Mixmatches of indoor coil capacity more than 1 size larger than outdoor unit capacity (unless so specified) may result in inadequate indoor comfort. Do not apply capillary tube indoor coils to these units. Factory-supplied filter drier must be installed. MATCHED SYSTEM HEAT PUMP VENTILATOR PLUS ZONE PERFECT PLUS ™ EQUIPMENT CONTROLLER FAN COIL HUMIDIFIER AIR CLEANER A98536 —18— —19— SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: • Unit Familiarization • Maintenance • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG 1-800-962-9212 [ ] Packaged Service Training [ ] Classroom Service Training A94328 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS 650A.24.1 © 1998 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indianapolis, IN 46231 —20— PRINTED IN U.S.A. Catalog No. 5265-002 1-99
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : 3.1-701 Create Date : 1999:02:02 11:11:49Z Modify Date : 2005:11:14 11:50:02-05:00 Metadata Date : 2005:11:14 11:50:02-05:00 Producer : Acrobat Distiller 2.0 for Windows Keywords : Format : application/pdf Title : Description : Creator : Carrier Corporation Subject : Document ID : uuid:d58a33b3-c605-4116-874d-4a1ab6090b77 Instance ID : uuid:1a726915-2b6a-4a3b-83e5-050343d86999 Page Count : 20 Author : Carrier CorporationEXIF Metadata provided by EXIF.tools