QUANTUM PLUS 13 SEER
HEAT PUMP WITH
PURON™ REFRIGERANT

The Quantum Plus line of split-system outdoor units has been
expanded to include the Model 650A 13 SEER heat pump
(with efficiencies up to 14.5 SEER). Homeowners will appreciate the Quantum Plus with Puron Refrigerant because of its
efficiency, environmental soundness and its availability for
years to come.
Another benefit of the Quantum Plus is the durability of the
scroll compressor. Model 650A has received certifications
from UL, c-UL, ARI, CEC, and CSA-EEV. The 650A is also
approved by Energy StarSM for energy efficiency and by Green
Seal for efficiency and environmental soundness.
FEATURES
REFRIGERANT—The environmentally sound refrigerant
used in the 650A is Puron. This advanced refrigerant contains no chlorine which can contribute to ozone depletion in
the atmosphere, so it’s a smart choice for homeowners who
are concerned with protecting our environment, now and for
future generations. And it’s a smart choice for anyone interested in high-efficiency cooling.
RELIABLE BUILT-IN COMPONENTS—All units include a
suction line accumulator that minimizes the amount of liquid
refrigerant that reaches the compressor; a high-pressure
switch for high-pressure protection; a low-pressure switch for
loss of charge protection; and a liquid-line filter drier to
remove any moisture or foreign matter from the system. A
crankcase heater is standard on the 048 and 060 sizes.
COMPRESSOR PROTECTION—Each scroll compressor
motor is protected with internal temperature and currentsensitive overloads. For improved serviceability each compressor is equipped with a compressor terminal plug.
UNIT DESIGN—Copper tube, enhanced aluminum fin coil
is designed for strong heat transfer. Vertical air discharge
carries sound and hot condenser air up and away from
adjacent patio areas and foliage. Heat pump style base pan
is popular for its easy removal of water, dirt, and leaves.
The AeroQuiet System (AQS) consists of 4 design features
to achieve ultra-low sound ratings.
Aerocoustic Design featuring the Aeromax opening and

650A (60 Hz)
Sizes 024 thru 060

wire dome top results in quieter and more efficient operation.
Energy-Efficient Fan and Fan Motor provide a slower fan
operation, thus reducing noise and improving efficiency.
Sound Hood muffles noise from operation.
Discharge Muffler minimizes low frequency sound and
pressure pulsation generated by compressor discharge gas.
WEATHER-PROTECTIVE CABINET—Steel is galvanized
and coated with a layer of zinc phosphate. A layer of modified
polyester powder is then applied and baked on, providing
each unit with a durable finish that will last for many years.
All screws on cabinet exterior are coated for a long-lasting,
rust-resistant, quality appearance.
COIL PROTECTION—The DuraGuard coil protector, made of
a 12 gage coated steel wire grid with vertical 3/8-in. spacing, is
designed to help protect the coil from inclement weather, vandalism, and incidental damage. It provides protection while not
restricting airflow and maintaining ease of coil inspection and
cleaning.
EASY SERVICEABILITY—One access panel provides
access to electrical controls and compressor. Removal of
wire dome gives access to fan motor and removal of the top
gives access to the coil.
WIDE RANGE OF SIZES—Available in 6 nominal sizes from
024 through 060 to meet the needs of residential and light
commercial applications.
LIMITED WARRANTY—Standard 1-year limited warranty on
parts, with an additional 9-year limited warranty on compressor.
TOTALLY ENCLOSED FAN MOTOR—Means greater reliability under adverse weather conditions and dependable
performance for many years. Permanent split-capacitor-type
motors provide more economical operation.
DEFROST CONTROL BOARD—Incorporates a built-in
5-minute compressor time-delay relay, defrost relay, defrost
timer, and low-voltage terminal board. The defrost control is a
time/temperature initiation/termination control, which includes
3 field-selectable time periods of 30, 50, and 90 minutes.
APPLICATION VERSATILITY—Due to PressureGuard™
the 650A can be combined with a wide variety of evaporator
coils and blower packages to provide quiet, dependable
comfort. The 650A can be installed on a roof or at ground
level on a slab.
EXTERNAL SERVICE VALVES—Both service valves are
brass, back seating type with sweat connections. Valves are
externally located so refrigerant tube connections can be
made quickly and easily. Each valve has a service port for
ease of checking operating refrigerant pressures.
THERMOSTATIC EXPANSION VALVE (TXV)—This unit
must be installed with a Puron™ approved TXV on the
indoor coil. The FX4 and FV4 fan coils come factory
equipped with Puron TXVs. When installed with these fan
coils, no further change is required. For any other coil
combination, the approved field accessory Puron TXV
must be installed. For applications with fan coils such as the
FC4 and FK4 which have R-22 TXVs, the R-22 TXV must be
replaced with the approved field accessory Puron TXV.
ELECTRICAL RANGE—All units are offered in 208/230v
single phase only.

Form No. PDS 650A.24.2

UNIT
SIZE
024
030
036
042
048
060

—2—

SERIES
A,C
A,C
A,C
A,C
A,C
B,C

A
39-13/16
33-13/16
27-13/16
27-13/16
39-13/16
39-13/16

AIR DISCHARGE

AIR IN

AIR DISCHARGE

L

B
30
30
30
30
30
30

AIR IN

AIR IN

C
33
33
33
33
33
33

8 3/16"

C
L

D
5-1/16
5-1/16
5-1/16
5-1/16
5-1/16
5-1/16

E

D

K

E
9-11/16
9-11/16
9-11/16
9-11/16
9-11/16
9-11/16

N

1 9/16"

2 1/2"

UNIT DIMENSIONS
F
G
27-15/16
34-3/8
21-15/16
28-3/8
15-15/16
22-3/8
15-15/16
22-3/8
27-15/16
34-3/8
27-15/16
34-3/8

DIMENSIONS (IN.)

AIR DISCHARGE

C

3/8 IN. DIA (9.5) TIEDOWN KNOCKOUTS
(2) PLACES IN BASEPAN

H
5/8
3/4
3/4
7/8
7/8
7/8

K
15-7/8
14
16-1/8
16-1/4
16-1/4
16

1 3/4"

4"

L
14-3/8
13-1/8
14-1/8
14
14-1/4
13-3/4

10 1/2"

3/8 IN. DIA LIQUID
LINE CONN

LINE CONN

H DIA SUCTION

FIELD CONTROL
SUPPLY CONN
7/8 IN. DIA HOLE

F

G

M

M
14-1/4
13-3/4
13-1/4
13-1/8
14-1/2
14

A

N
2-15/16
2-15/16
2-15/16
2-15/16
2-15/16
2-15/16

1 1/4"

FIELD POWER SUPPLY CONN 7/8 IN. DIA (22.22)
HOLE WITH 1 1/8 IN. DIA (34.92) KNOCKOUT
AND 1 3/8 IN. DIA KNOCKOUT

1.Allow 30 in. clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side,
and 24 in. between units for proper airflow.
2.Minimum outdoor operating ambient in cooling mode is 55°F (unless low ambient control is used) max 125°F.
3.Maximum outdoor operating ambient in heating mode is 66°F.
4.Series designation is the 14th position of the unit model number.
5.Center of gravity
.

NOTES:

MINIMUM MOUNTING
PAD DIMENSIONS
Support Feet Snow Stand
26 x 32
31 x 35
26 x 32
31 x 35
26 x 32
31 x 35
26 x 32
31 x 35
26 x 32
31 x 35
26 x 32
31 x 35

A94148

ACCESS
PANEL

B

DIMENSIONS

RECOMMENDED TUBE DIAMETERS
LIQUID TUBE DIAMETER (IN.)
0 to 50 Ft
Tube Length
Alternate
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8

UNIT
SIZE
024
030
036
042, 048
060

VAPOR TUBE DIAMETER (IN.)
0 to 50 Ft
Tube Length
5/8
3/4
3/4
7/8
1-1/8

Alternate
3/4 ACR
7/8
7/8
7/8
7/8

RST*
(Not Permitted)
3/4
1-1/8
1-1/8
3/4 and 1-1/8
3/4

* RST—Refrigeration Service Tubing, standard refrigerant grade tubing.
NOTES:
1. Tube diameters are for lengths up to 50 ft. For tubing lengths greater than 50 ft, consult the Application Guideline and Service Manual for Residential SplitSystem Air Conditioners and Heat Pumps using Puron Refrigerant.
2. Refrigerant tubes and indoor coils must be evacuated to 500 microns to minimize contamination and moisture in the system.

METERING DEVICE
UNIT SIZE
024
030
036
042
048
060

SERIES
A,C
A,C
A,C
A,C
A,C
B,C

OUTDOOR PISTON
46
52
57
59
61
73

INDOOR TXV*
KSATX0201HSZ
KSATX0201HSZ
KSATX0301HSZ
KSATX0301HSZ
KSATX0401HSZ
KSATX0501HSZ

REQUIRED SUBCOOLING
(°F)
11
9
9
11
10
12

* TXV must be installed when indoor coil is not equipped with a Puron approved TXV. TXV listed is for any approved coil combination. All TXVs are Puron specific bi-flow hard shutoff.

SOUND RATING (dBA)
UNIT SIZE–SERIES
024-A,C
030-A,C
036-A,C
042-A,C
048-A,C
060-B,C

Meets GREEN SEAL Environmental Criteria
for high energy efficiency, low noise, and
recycled packaging. Does not use an ozone
depleting substance during manufacturing,
or as a refrigerant.

A

AIR
CO

Y

NING
ITIO
ND

UNIT
AR

T
IFIED O ARI A
RT
S
C
CE

EQ

RI

YING WITH
PL
OM

MANUFACTUR
ER

As an ENERGY STARSM
partner, Bryant Heating &
Cooling Systems has
determined that this product meets the ENERGY
STAR guidelines for
energy efficiency.

SOUND RATING
72
74
76
76
78
78

UIP M E N T

STA

NDARD

21

0

CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.

REGISTERED QUALITY SYSTEM

—3—

SPECIFICATIONS
UNIT SIZE-SERIES
Operating Weight (Lb)

024-A,C

030-A,C

036-A,C

214

205

217

ELECTRICAL
Unit Volts—Hertz—Phase

208/230—60—1

Operating Voltage Range*

187—253

Compressor Rated Load Amps

15.1

14.7

15.4

Compressor Locked Rotor Amps

61.0

72.5

83.0

Condenser Fan Motor—Full Load Amps

0.8

1.1

1.1

Minimum Unit Ampacity for Wire Sizing

19.7

19.5

20.4

Minimum Wire Size (60°C Copper) (AWG)†

14

14

12

Minimum Wire Size (75°C Copper) (AWG)†

14

14

12

Maximum Wire Length (60°C) (Ft)‡

39

39

60

Maximum Wire Length (75°C) (Ft)‡

37

37

57

Maximum Branch Circuit Fuse Size**

30

30

30

COMPRESSOR & REFRIGERANT
Compressor Manufacturer

Copeland

Compressor Type

Scroll

Refrigerant Type

Puron

Refrigerant Amount (Lb)††

7.18

6.63

8.87

OUTDOOR COIL & FAN
Coil Face Area (Sq Ft)
Fins per In.—Rows—Circuits
Fan Motor—HP & RPM
Rated Airflow (CFM)

18.18

15.15

12.12

25—1—2

25—1—3

20—2—3

1/8 and 825

1/5 and 825

1/5 and 825

2400

2800

2800

OPTIONAL EQUIPMENT
Support Feet—4 In. (4)

KSASF0101AAA

Snow Stand—18 In.
Time Delay Relay

KHASS0206MPK
KAATD0101TDR

Interface Control (Energy Minder)‡‡

KHAIC0101AAA

Service Alarm***

KHASA0101AAA

Outdoor Thermostat

KHAOT0301FST

Secondary Outdoor Thermostat

KHAOT0201SEC

Crankcase Heater

KAACH1201AAA

Start Assist—Capacitor/Relay Type

KSAHS1501AAA

Start Assist—PTC Type

Standard

Bi-Flow TXV (Hard Shutoff)

KSATX0201HSZ

Filter Drier (Suction Line)

KH45LG140 (RCD)

Evaporator Freeze Thermostat†††

KAAFT0101AAA

Isolation Relay†††

KHAIR0101AAA

Liquid-Line Solenoid Valve (LSV)

KHALS0401LLS

Low-Ambient Pressure Switch

KSALA0301410

See notes on page 5.

—4—

KSATX0301HSZ

SPECIFICATIONS Continued
UNIT SIZE-SERIES
Operating Weight (Lb)

042-A.C

048-A,C

060-B,C

218

266

295

ELECTRICAL
Unit Volts—Hertz—Phase

208/230—60—1

Operating Voltage Range*

187—253

Compressor Rated Load Amps

21.1

20.5

27.6

Compressor Locked Rotor Amps

104.0

109.0

158.0

Condenser Fan Motor—Full Load Amps

1.1

1.4

1.4

Minimum Unit Ampacity for Wire Sizing

27.5

27.0

35.9

Minimum Wire Size (60°C Copper) (AWG)†

10

10

8

Minimum Wire Size (75°C Copper) (AWG)†

10

10

8

Maximum Wire Length (60°C) (Ft)‡

71

74

86

Maximum Wire Length (75°C) (Ft)‡

68

70

82

Maximum Branch Circuit Fuse Size**

40

40

60

COMPRESSOR & REFRIGERANT
Compressor Manufacturer

Copeland

Compressor Type

Scroll

Refrigerant Type

Puron

Refrigerant Amount (Lb)††

8.63

13.25

13.25

OUTDOOR COIL & FAN
Coil Face Area (Sq Ft)
Fins per In.—Rows—Circuits
Fan Motor—HP & RPM
Rated Airflow (CFM)

12.12

18.18

18.18

20—2—3

20—2—4

20—2—5

1/5 and 825

1/4 and 1100

1/4 and 1100

2800

3300

3300

OPTIONAL EQUIPMENT
Support Feet—4 In. (4)

KSASF0101AAA

Snow Stand—18 In.
Time Delay Relay

KHASS0206MPK
KAATD0101TDR

Interface Control (Energy Minder)‡‡

KHAIC0101AAA

Service Alarm***

KHASA0101AAA

Outdoor Thermostat

KHAOT0301FST

Secondary Outdoor Thermostat

KHAOT0201SEC

Crankcase Heater

KAACH1201AAA

Standard

Start Assist—Capacitor/Relay Type

KSAHS1501AAA

KSAHS1601AAA

Start Assist—PTC Type
Bi-Flow TXV (Hard Shutoff)

Standard
KSATX0301HSZ

Filter Drier (Suction Line)

KAACS0201PTC
KSATX0401HSZ

KSATX0501HSZ

KH45LG141 (RCD)

Evaporator Freeze Thermostat†††

KAAFT0101AAA

Isolation Relay†††

KHAIR0101AAA

Liquid-Line Solenoid Valve (LSV)

KHALS0401LLS

Low-Ambient Pressure Switch

KSALA0301410

* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If other than uncoated (non-plated), 60°C or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than
10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable
(NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26.
‡ Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 percent.
** Time-delay fuse or circuit breaker.
†† The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, refer to the Residential Split-Systems Long-Line
Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using Puron (R-410A).
‡‡ Outdoor thermostat required.
*** For indicator function, thermostat specified must be used and wired according to service alarm Installation Instructions.
††† Use with low-ambient pressure switch.
NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.

—5—

THERMOSTATS AND ACCESSORIES
Thermostat—Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool

TSTATBBNHP01-B

Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool

TSTATBBPHP01-B

Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, Dual Fuel, Includes Outdoor
Sensor (TSTATXXSEN01)

TSTATBBPDF01-B*

Thermidistat™ Control—Non-Programmable/Programmable Thermostat with Humidity
Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air
Temperature Sensor.)

TSTATBBPRH01-B*

Builder’s Thermostat—Manual Changeover, Non-Programmable, °F/°C, 2-Stage Heat,
1-Stage Cool, Heat Pump

TSTATBBBHP01*

Outdoor Air Temperature Sensor

TSTATXXSEN01

Backplate for Non-Programmable Thermostat

TSTATXXNBP01†

Backplate for Programmable Thermostat and Thermidistat™ Control

TSTATXXPBP01†

Backplate for Builder’s Thermostat

TSTATXXBBP01†

Thermostat Conversion Kit (4 to 5 Wire)—10 Pack

TSTATXXCNV10‡

* Do not use in zoning heat pump applications.
† This plate is designed to cover surrounding wall area located behind thermostat.
‡ Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used
to replace a broken thermostat wire, or add an extra wire when needed.
** Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version and
builder’s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat.
The outdoor air temperature sensor must be used with the dual fuel thermostat.
The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.

ACCESSORY USAGE GUIDELINE
ACCESSORY

REQUIRED FOR LOW-AMBIENT
APPLICATIONS
(Below 55°F)

REQUIRED FOR LONG-LINE
APPLICATIONS*
(Over 50 Ft)

Crankcase Heater

Yes

Yes

Evaporator Freeze Thermostat

Yes

No

Compressor Start Assist—Capacitor and Relay

Yes

Yes

Puron Low-Ambient Pressure Switch

Yes

No

Wind Baffle

See Low-Ambient
Pressure Switch Instructions

No

Support Feet

Recommended

No

Puron Hard Shutoff TXV

Yes†

Yes†

Puron Liquid-Line Solenoid Valve for Heating

No

See Long-Line
Application Guideline

* For tubing line sets between 50 and 175 ft and/or 20 ft elevation difference between indoor and outdoor units, refer to the Application Guideline
and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using Puron Refrigerant.
† Required for all applications.

—6—

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
1. Compressor Start Assist—Capacitor and Relay
Start capacitor and start relay which gives a “hard” boost to compressor motor at each start-up.
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.
Installations where outdoor design temperature exceeds 105°F (40.6°C).
Units installed with Low Ambient Pressure Switch. Units installed with Liquid-Line Solenoid Valve.
2. Compressor Start Assist—PTC Type
Solid-state electrical device which gives a “soft” boost to the compressor at each start-up.
SUGGESTED USE: Installations with marginal power supply.
3. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication
on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. (Use with Low-Ambient Pressure Switch.)
All commercial installations.
4. Evaporator Freeze Thermostat
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.
SUGGESTED USE: All units to which Low-Ambient Pressure Switch has been added.
5. Filter Drier—Suction Line
A device for removing contaminants from refrigerant circulating in a heat pump system; 2-direction flow for heat pumps.
SUGGESTED USE: Split-system heat pumps.
6. Interface Control (Energy Minder)
An electric control for controlling a heat pump and gas or oil furnace system for maximum energy savings. It allows heat pump to operate down to a
predetermined economic balance point temperature, then switches to allow furnace operation only below that temperature. Requires outdoor thermostat
(Item 11) to be adjusted for economic balance point temperature.
SUGGESTED USE: For heat pump and gas- or oil-fired furnace combination systems unless Duel Fuel Thermostat or Thermidistat™ Control is used.
7. Isolation Relay
An SPDT relay which switches the Low-Ambient Controller out of the outdoor fan motor circuit when the heat pump switches to heating mode.
SUGGESTED USE: All heat pumps where Low-Ambient Pressure Switch has been added.
8. Liquid-Line Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor unit which stops and starts refrigerant liquid flow in response to compressor operation.
Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.
SUGGESTED USE: In long-line applications. (Refer to the Residential Split-System Long-Line Application Guideline and Service Manual.)
9. Low-Ambient Pressure Switch
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure
within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at low-ambient temperatures down to
0°F (–17.8°C) when properly installed.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).
10. Outdoor Air Temperature Sensor
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat.
SUGGESTED USE: All Bryant programmable thermostats.
11. Outdoor Thermostat
An SPDT temperature actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below set point.
SUGGESTED USE: Heat pump installations with multiple-stage supplemental heaters.
12. Secondary Outdoor Thermostat
An SPDT temperature actuated switch which turns on a third stage of supplemental electric heaters when outdoor air temperature drops below the
second-stage set point.
SUGGESTED USE: Heat pump installations where 3-stage operation of supplemental heaters is desired.
13. Service Alarm
A current-sensing lockout relay which provides immediate notification that compressor is not operating during a call for heating or cooling. Used with
proper room thermostat, a thermostat signal is turned on signifying service is required. This can minimize electrical cost increase due to operation of
supplemental heaters only.
SUGGESTED USE: As a feature to notify owner immediately when the system is not operating most efficiently.
14. Snow Stand
Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base.
SUGGESTED USE: Heat pump installations in heavy snowfall areas.
Heat pump installations in snowdrift locations.
Heat pump installations in areas of prolonged subfreezing temperatures.
All commercial installations.
15. Support Feet
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base;
minimizes corrosion.
SUGGESTED USE: Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
16. Thermostatic Expansion Valve (TXV)—Bi-Flow
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the
evaporator. Kit includes valve, adapter tubes, and external equalizer tube.
SUGGESTED USE: Required for all installations.
17. Time-Delay Relay
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. (Refer to ARI Unitary Directory.)
Required for use on all zoning systems.

—7—

COMBINATION RATINGS*

UNIT
SIZESERIES

024-A,C

030-A,C

036-A,C

042-A,C

048-A,C

INDOOR
UNIT
FX4ANF030†
F(A,B)4AN(F,C)030
FC4BNF030
FK4CNF001
FK4CNF002
FK4CNF003
FV4ANF002
FV4ANF003
CC5A/CD5AA036
CD5AW036
CE3AA036
CJ5A/CK5A/CK5BA036
CJ5A/CK5A/CK5BW036
CJ5A/CK5A/CK5BN036
CK3BA036
FX4ANF030†
F(A,B)4AN(F,C)036
FC4BNF036
FK4CNF001
FK4CNF002
FK4CNF003
FV4ANF002
FV4ANF003
FX4ANF036
CC5A/CD5AA036
CD5AW036
CE3AA036
CJ5A/CK5A/CK5BN036
CJ5A/CK5A/CK5BW036
CK3BA036
FX4ANF042†
F(A,B)4AN(F,B,C)042
FC4BN(F,B)042
FK4CNF003
FK4CNF005
FV4ANF003
FV4ANF005
CC5A/CD5AA042
CC5A/CD5AW042
CC5A/CD5AC048
CC5A/CD5AW048
CD5AA048
CE3AA042
CE3AA048
CJ5A/CK5A/CK5BA042
CJ5A/CK5A/CK5BN042
CJ5A/CK5A/CK5BA048
CJ5A/CK5A/CK5BN048
CJ5A/CK5A/CK5BW048
CK3BA042
CK3BA048
FV4ANF003†
F(A,B)4AN(F,B,C)048
FC4BN(F,B)048
FK4CNF003
FK4CNF005
FV4ANF005
FX4ANF042
CE3AA048
CJ5A/CK5A/CK5BA048
CJ5A/CK5A/CK5BN048
CJ5A/CK5A/CK5BW048
CK3BA048
FV4ANF005†
F(A,B)4AN(F,B,C)060
FB4ANB070
FC4BN(F,B)060
FC4BNB070
FK4CNF005
FK4CNB006
FV4ANB006
FX4ANF048
FX4ANB060
CE3AA060

CFM††
800
800
800
700
700
700
700
700
900
900
800
800
800
800
800
1050
1050
1050
875
875
875
875
875
1050
1080
1080
1050
1000
1050
1050
1125
1125
1125
1050
1050
1050
1050
1125
1260
1260
1275
1275
1125
1125
1125
1125
1125
1125
1125
1125
1125
1225
1400
1400
1225
1225
1225
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400

TC
25,000
23,600
24,000
24,400
25,200
25,200
25,200
25,200
24,000
24,000
23,800
24,200
24,200
24,200
24,200
29,000
28,400
28,400
28,600
28,800
29,000
29,200
29,400
29,000
28,800
28,800
28,600
28,800
28,800
28,800
35,000
33,600
33,600
34,000
35,400
34,400
35,600
34,000
33,600
33,600
34,000
34,000
34,000
34,200
33,800
33,800
34,200
34,200
34,200
33,800
34,200
40,500
40,000
40,500
40,500
41,000
41,000
40,500
40,500
40,000
40,000
40,000
4,0000
45,500
44,500
46,000
44,500
46,000
45,500
46,500
46,500
45,000
45,500
45,500

ARI STANDARD RATINGS*
Cooling
Seasonal Efficiency SEER
Field-Supplied
High-Temp
FactoryAccessory‡
Supplied
Enhance- Standard Puron Puron TXV
TXV & TDR** EER
TC
COP
ment
Rating
TDR&TXV
13.00
—
—
11.10 25,000
3.30
TDR
—
12.50
—
10.95 24,400
3.18
TDR
—
12.50
—
10.95 24,400
3.18
TDR
—
13.80
—
12.00 23,800
3.30
TDR
—
14.00
—
12.35 25,000
3.58
TDR
—
14.20
—
12.60 25,200
3.54
TDR&TXV
14.20
—
—
12.05 25,200
3.44
TDR&TXV
14.50
—
—
12.35 25,000
3.44
NONE
—
—
13.00
11.10 24,800
3.28
NONE
—
—
13.00
11.10 24,800
3.28
NONE
—
—
12.60
11.05 24,600
3.20
NONE
—
—
13.00
11.20 24,800
3.34
NONE
—
—
13.00
11.20 24,800
3.34
NONE
—
—
13.00
11.20 24,800
3.34
NONE
—
—
13.00
11.20 24,800
3.34
TDR&TXV
13.00
—
—
11.15 30,000
3.56
TDR
—
12.20
—
10.75 29,800
3.42
TDR
—
12.20
—
10.75 29,800
3.42
TDR
—
13.70
—
12.10 28,600
3.54
TDR
—
13.70
—
12.15 29,000
3.68
TDR
—
14.20
—
12.55 28,600
3.68
TDR&TXV
14.00
—
—
12.15 29,000
3.68
TDR&TXV
14.50
—
—
12.55 28,600
3.70
TDR&TXV
12.30
—
—
10.85 30,000
3.52
NONE
—
—
13.00
11.25 29,400
3.52
NONE
—
—
13.00
11.25 29,400
3.52
NONE
—
—
12.70
11.15 29,200
3.44
NONE
—
—
12.70
11.25 29,400
3.54
NONE
—
—
13.00
11.30 29,400
3.56
NONE
—
—
13.00
11.30 29,400
3.56
TDR&TXV
13.00
—
—
10.80 35,000
3.40
TDR
—
12.30
—
10.65 34,200
3.26
TDR
—
12.30
—
10.65 34,200
3.26
TDR
—
13.70
—
11.80 33,600
3.40
TDR
—
14.00
—
12.30 33,800
3.70
TDR&TXV
13.70
—
—
11.80 33,600
3.44
TDR&TXV
14.00
—
—
12.30 34,000
3.70
NONE
—
—
12.50
10.65 34,000
3.20
NONE
—
—
12.20
10.50 34,000
3.16
NONE
—
—
12.20
10.50 33,600
3.10
NONE
—
—
12.50
10.60 34,200
3.24
NONE
—
—
12.50
10.65 34,200
3.26
NONE
—
—
12.50
10.65 34,200
3.26
NONE
—
—
12.50
10.70 34,200
3.30
NONE
—
—
12.50
10.60 34,200
3.26
NONE
—
—
12.50
10.60 34,200
3.26
NONE
—
—
12.50
10.70 34,400
3.32
NONE
—
—
12.50
10.70 34,400
3.32
NONE
—
—
12.50
10.70 34,400
3.32
NONE
—
—
12.50
10.60 34,200
3.26
NONE
—
—
12.50
10.70 34,400
3.32
TDR&TXV
13.00
—
—
11.00 40,500
3.36
TDR
—
12.00
—
10.25 41,500
3.34
TDR
—
12.00
—
10.25 41,500
3.38
TDR
—
13.00
—
11.10 40,000
3.32
TDR
—
13.50
—
11.55 40,000
3.56
TDR&TXV
14.00
—
—
11.55 40,000
3.56
TDR&TXV
12.00
—
—
10.25 41,500
3.40
NONE
—
—
12.00
10.35 41,500
3.32
NONE
—
—
12.00
10.30 41,500
3.34
NONE
—
—
12.00
10.30 41,500
3.34
NONE
—
—
12.00
10.30 41,500
3.34
NONE
—
—
12.00
10.30 41,500
3.34
TDR&TXV
13.50
—
—
11.60 47,500
3.58
TDR
—
11.70
—
10.20 48,500
3.32
TDR
—
12.50
—
10.90 48,000
3.54
TDR
—
11.70
—
10.20 48,000
3.32
TDR
—
12.50
—
10.90 48,000
3.54
TDR
—
13.20
—
11.60 48,000
3.58
TDR
—
14.00
—
12.05 48,000
3.76
TDR&TXV
14.10
—
—
12.05 48,000
3.76
TDR&TXV
12.50
—
—
10.75 48,000
3.42
TDR&TXV
12.60
—
—
10.90 48,000
3.54
NONE
—
—
12.50
10.80 48,000
3.40

See notes on page 9.

—8—

Heating
Low-Temp
TC
16,600
16,500
16,500
16,000
16,100
16,000
16,100
15,900
16,600
16,600
16,600
16,600
16,600
16,600
16,600
18,500
18,700
18,700
17,800
17,900
17,700
17,900
17,700
18,800
18,500
18,500
18,500
18,500
18,500
18,500
21,600
21,400
21,400
20,600
20,800
20,600
20,800
21,400
21,400
21,400
21,400
21,400
21,600
21,600
21,600
21,600
21,600
21,600
21,600
21,600
21,600
25,400
26,600
26,600
25,400
25,200
25,200
26,600
26,400
26,400
26,400
26,400
26,400
27,600
29,000
28,600
29,000
28,600
27,800
27,600
27,600
28,400
28,600
28,400

COP
2.38
2.32
2.32
2.42
2.54
2.54
2.48
2.48
2.36
2.36
2.34
2.38
2.38
2.38
2.38
2.38
2.32
2.32
2.44
2.48
2.50
2.48
2.52
2.36
2.38
2.38
2.36
2.38
2.40
2.40
2.34
2.28
2.28
2.40
2.52
2.40
2.52
2.26
2.24
2.22
2.28
2.28
2.28
2.30
2.28
2.28
2.30
2.30
2.30
2.28
2.30
2.46
2.42
2.42
2.44
2.56
2.56
2.42
2.40
2.40
2.40
2.40
2.40
2.46
2.26
2.38
2.26
2.38
2.46
2.54
2.54
2.34
2.38
2.34

HSPF
8.00
7.50
7.50
7.75
8.00
8.00
8.00
8.00
7.50
7.50
7.40
7.50
7.50
7.50
7.50
8.00
7.40
7.40
7.80
8.00
8.00
8.10
8.10
8.00
7.65
7.65
7.45
7.65
7.70
7.70
7.70
7.40
7.40
7.70
8.00
7.80
8.10
7.30
7.30
7.30
7.30
7.30
7.40
7.45
7.40
7.40
7.50
7.50
7.50
7.40
7.50
7.70
7.50
7.55
7.40
8.00
8.10
7.55
7.40
7.50
7.50
7.50
7.50
8.50
7.80
8.00
7.70
8.00
8.20
8.50
8.60
8.00
8.10
8.00

COMBINATION RATINGS Continued

UNIT
SIZESERIES
048-A,C

060-B,C

INDOOR
UNIT
CJ5A/CK5A/CK5BA060
CJ5A/CK5A/CK5BN060
CJ5A/CK5A/CK5BX060
CK3BA060
FV4ANB006†
FB4ANB070
FC4BNB070
FK4CNB006
FX4ANB060
CC5A/CD5AW060
CJ5A/CK5A/CK5BX060

CFM††
1400
1400
1400
1400
1750
1750
1750
1750
1750
1750
1750

TC
45,000
45,500
45,500
45,000
58,000
57,000
57,000
58,000
57,000
56,000
56,500

ARI STANDARD RATINGS*
Cooling
Seasonal Efficiency SEER
Field-Supplied
High-Temp
FactoryAccessory‡
Supplied
Enhance- Standard Puron Puron TXV
TXV & TDR** EER
TC
COP
ment
Rating
NONE
—
—
12.50
10.75 48,000
3.50
NONE
—
—
13.00
10.90 48,500
3.52
NONE
—
—
13.00
10.90 48,500
3.52
NONE
—
—
12.50
10.75 48,000
3.50
TDR&TXV
13.00
—
—
10.75 60,000
3.56
TDR
—
12.00
—
10.20 60,000
3.44
TDR
—
12.00
—
10.20 60,000
3.44
TDR
—
12.80
—
10.75 59,500
3.56
TDR&TXV
12.00
—
—
10.20 60,000
3.44
NONE
—
—
12.50
10.45 58,500
3.26
NONE
—
—
12.50
10.55 59,000
3.44

Heating
Low-Temp
TC
28,600
28,600
28,600
28,600
37,000
37,800
37,800
37,000
37,800
36,800
37,000

COP
2.38
2.38
2.38
2.38
2.54
2.46
2.46
2.54
2.46
2.42
2.50

HSPF
8.20
8.25
8.25
8.20
8.00
7.80
7.80
8.00
7.80
7.50
7.70

* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.
‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.
** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the
394HAD.
†† Indoor Airflow
COP — Coefficient of Performance
EER — Energy Efficiency Ratio
HSPF — Heating Seasonal Performance Factor
SEER — Seasonal Energy Efficiency Ratio
TC
— Total Capacity (Btuh)
TDR — Time-Delay Relay
TXV
— Thermostatic Expansion Valve

—9—

650A BALANCE POINT WORKSHEET

8.8

11.7

14.7

17.6

23.4

650AN060-B,C
FV4A006

650AN048-A,C
FV4A005

650AN042-A,C
FV4A003

650AN036-A,C
FX4A042

650AN030-A,C
FX4A030

650AN024-A,C
FX4A030

80

80

60

50

40

30

50

BASED ON INDOOR ENT. AIR AT
70˚F AND AT RATED CFM

60

70

5.9

40

20

30

2.9

20

10

10

20.5

0

A99002

—10—

70

-10

OUTDOOR TEMPERATURE, ˚F

KW

NOTE: The performance shown includes the PressureGuard™ cycling the outdoor fan. The ambient temperature that the outdoor fan
cycles depends on the outdoor/indoor combination, indoor airflow, installation practices, and system maintenance, all of which affect
system performance.

BUILDING HEAT LOSS, 1000 BTU/HR
UNIT INTEGRATED HEATING CAPACITY, 1000 BTU/HR

DETAILED COOLING CAPACITIES*
EVAP
AIR

CFM

EWB

75
Capacity
Total
MBtuh†
Sys
Total Sens‡ Kw**

CONDENSER ENTERING AIR TEMPERATURES °F
85
95
105
115
Capacity
Capacity
Capacity
Capacity
Total
Total
Total
Total
MBtuh†
MBtuh†
MBtuh†
MBtuh†
Sys
Sys
Sys
Sys
Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**

125
Capacity
Total
MBtuh†
Sys
Total Sens‡ Kw**

650AN024-A,C
, Outdoor Section With FX4ANF030 Indoor Section
700

800

900

72
67
63††
62
57
72
67
63††
62
57
72
67
63††
62
57

29.7
27.2
25.3
24.8
23.7
30.3
27.7
25.8
25.4
24.7
30.8
28.2
26.2
25.9
25.5

Indoor
Section
FX4ANF

14.5
18.2
17.7
21.7
23.7
15.2
19.3
18.8
23.3
24.7
15.8
20.4
19.8
24.7
25.5

1.85
1.85
1.85
1.84
1.84
1.88
1.88
1.88
1.88
1.88
1.92
1.92
1.92
1.92
1.91

Size
030

28.4
14.0
2.07
26.9
13.5
2.31
25.4
12.9
2.57
23.8
25.9
17.6
2.06
24.6
17.1
2.30
23.2
16.5
2.55
21.7
24.1
17.2
2.06
22.9
16.6
2.29
21.6
16.1
2.54
20.2
23.7
21.2
2.06
22.5
20.6
2.29
21.3
20.0
2.54
20.0
22.8
22.8
2.06
21.9
21.9
2.29
20.9
20.9
2.54
19.8
28.9
14.6
2.11
27.3
14.1
2.35
25.8
13.6
2.61
24.1
26.4
18.7
2.10
25.0
18.2
2.34
23.6
17.6
2.59
22.0
24.6
18.2
2.10
23.3
17.7
2.33
21.9
17.1
2.58
20.5
24.2
22.7
2.10
23.0
22.1
2.33
21.8
21.4
2.58
20.5
23.7
23.7
2.10
22.7
22.7
2.33
21.6
21.6
2.58
20.5
29.3
15.3
2.14
27.7
14.7
2.38
26.1
14.2
2.64
24.3
26.8
19.8
2.14
25.3
19.3
2.37
23.9
18.7
2.63
22.3
24.9
19.2
2.13
23.6
18.6
2.37
22.2
18.1
2.62
20.8
24.7
24.1
2.13
23.5
23.3
2.37
22.3
22.3
2.62
21.1
24.5
24.5
2.13
23.4
23.4
2.37
22.3
22.3
2.62
21.1
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Indoor
Capacity
Power
Section
Size
1.00
1.00
CE3AA
030

F(A,B)4AN(F,C)

030

0.94

1.00

FC4BNF

030

0.96

1.00

FK4CNF

FV4ANF

CJ5A/CK5A/CK5BA

12.3
15.9
15.5
19.4
19.8
13.0
17.0
16.5
20.5
20.5
13.6
18.1
17.4
21.1
21.1

2.85
2.83
2.82
2.81
2.81
2.88
2.87
2.85
2.85
2.85
2.92
2.90
2.89
2.89
2.89

22.0
20.1
18.7
18.6
18.6
22.2
20.4
19.0
19.2
19.2
22.4
20.5
19.1
19.7
19.7

11.7
15.3
14.8
18.5
18.6
12.3
16.4
15.8
19.2
19.2
12.9
17.4
16.7
19.7
19.7

Cooling
Capacity
0.94

Power
1.00

036

0.95

1.00

030

0.94

1.00

001

0.98

0.93

036

0.97

1.00

002

1.01

0.93

CJ5A/CK5A/CK5BN

036

0.97

1.00

003

1.01

0.91

CJ5A/CK5A/CK5BW

030

0.94

1.00

002

1.01

0.93

036

0.97

1.00

003

1.01

0.91

—

—

—

CK3BA

See notes on page 14.

—11—

030

0.94

1.00

036

0.97

1.00

3.14
3.12
3.11
3.11
3.11
3.18
3.16
3.15
3.15
3.15
3.22
3.20
3.19
3.19
3.19

DETAILED COOLING CAPACITIES* Continued
EVAP
AIR

CFM

EWB

75
Capacity
Total
MBtuh†
Sys
Total Sens‡ Kw**

CONDENSER ENTERING AIR TEMPERATURES °F
85
95
105
115
Capacity
Capacity
Capacity
Capacity
Total
Total
Total
Total
MBtuh†
MBtuh†
MBtuh†
MBtuh†
Sys
Sys
Sys
Sys
Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**

125
Capacity
Total
MBtuh†
Sys
Total Sens‡ Kw**

650AN030-A,C Outdoor Section With FX4ANF030 Indoor Section
1825

1050

1250

72
67
63††
62
57
72
67
63††
62
57
72
67
63††
62
57

34.3
31.4
29.2
28.8
27.8
35.2
32.4
30.2
29.9
29.8
35.8
32.9
30.7
31.0
31.0

17.2
21.7
21.1
26.2
27.8
18.7
24.3
23.6
29.4
29.8
20.0
26.5
25.6
31.0
31.0

2.07
2.06
2.04
2.04
2.04
2.14
2.13
2.11
2.11
2.11
2.20
2.19
2.17
2.17
2.17

32.6
16.6
2.31
30.9
15.9
2.58
29.0
15.3
2.87
27.0
29.9
21.1
2.29
28.3
20.5
2.56
26.6
19.8
2.86
24.8
27.8
20.5
2.28
26.4
19.9
2.55
24.8
19.2
2.84
23.1
27.4
25.5
2.28
26.0
24.8
2.55
24.5
24.0
2.84
23.0
26.7
26.7
2.27
25.6
25.6
2.54
24.3
24.3
2.84
23.0
33.5
18.1
2.38
31.6
17.4
2.65
29.7
16.8
2.94
27.6
30.7
23.7
2.36
29.0
23.0
2.63
27.2
22.3
2.93
25.3
28.6
22.9
2.35
27.0
22.3
2.62
25.4
21.5
2.91
23.6
28.6
28.5
2.35
27.2
27.2
2.62
25.8
25.8
2.91
24.3
28.5
28.5
2.35
27.2
27.2
2.62
25.8
25.8
2.91
24.3
34.0
19.4
2.44
32.1
18.7
2.71
30.0
18.1
3.00
27.8
31.2
25.8
2.42
29.4
25.1
2.69
27.6
24.4
2.98
25.6
29.1
24.9
2.41
27.5
24.2
2.67
25.7
23.4
2.97
23.9
29.7
29.7
2.41
28.3
28.3
2.68
26.8
26.8
2.98
25.1
29.7
29.7
2.41
28.3
28.3
2.68
26.8
26.8
2.98
25.1
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

Indoor
Section
FX4ANF

Size
030

F(A,B)4AN(F,C)
FC4BNF
FK4CNF

Capacity
1.00

Power
1.00

14.6
19.1
18.5
23.0
23.0
16.1
21.6
20.8
24.3
24.3
17.3
23.6
22.6
25.1
25.1

3.20
3.18
3.17
3.17
3.17
3.27
3.25
3.24
3.24
3.24
3.33
3.31
3.30
3.31
3.31

24.8
22.7
21.2
21.4
21.4
25.2
23.2
21.6
22.5
22.6
25.4
23.4
21.9
23.2
23.2

13.8
18.3
17.7
21.4
21.4
15.3
20.7
19.9
22.5
22.6
16.5
22.6
21.5
23.2
23.2

3.56
3.54
3.53
3.53
3.53
3.62
3.61
3.59
3.60
3.60
3.68
3.67
3.65
3.67
3.67

Cooling

Indoor
Section
FV4ANF

Size
002
003

1.01

0.90

FX4ANF

036

1.00

1.03

Capacity
1.01

Power
0.93

030

0.97

1.00

036

0.98

1.03

030

0.97

1.00

CE3AA

036

0.99

1.00

036

0.98

1.03

CJ5A/CK5A/CK5BN

036

0.99

1.00

001

0.99

0.92

CJ5A/CK5A/CK5BW

036

0.99

1.00

002

0.99

0.93

CK3BA

036

0.99

1.00

003

1.00

0.90

—

—

—

650AN036-A,C Outdoor Section With FX4ANF042 Indoor Section
1125

1250

1375

72
67
63††
62
57
72
67
63††
62
57
72
67
63††
62
57

42.3
38.7
36.1
35.5
34.7
42.7
39.2
36.6
36.1
35.7
43.1
39.6
36.9
36.7
36.6

21.3
27.3
26.5
33.0
34.7
22.1
28.6
27.8
34.8
35.7
22.8
30.0
29.0
36.4
36.6

2.64
2.63
2.63
2.63
2.63
2.69
2.68
2.68
2.68
2.68
2.74
2.73
2.73
2.73
2.73

40.3
20.6
2.93
38.3
19.8
3.26
36.0
19.1
3.61
33.7
36.9
26.5
2.93
35.0
25.8
3.25
33.0
25.0
3.60
30.8
34.4
25.7
2.92
32.6
25.0
3.24
30.6
24.1
3.59
28.6
33.9
32.2
2.92
32.2
31.4
3.24
30.4
30.3
3.59
28.7
33.3
33.3
2.92
31.9
31.9
3.24
30.4
30.4
3.59
28.7
40.7
21.4
2.98
38.6
20.6
3.31
36.3
19.9
3.66
33.9
37.3
27.9
2.98
35.4
27.1
3.30
33.2
26.3
3.65
31.0
34.8
27.0
2.97
32.9
26.2
3.29
31.0
25.4
3.64
28.8
34.5
33.9
2.97
32.8
32.8
3.29
31.2
31.2
3.64
29.4
34.3
34.3
2.97
32.8
32.8
3.29
31.2
31.2
3.64
29.4
41.1
22.1
3.03
38.9
21.4
3.36
36.6
20.6
3.71
34.1
37.7
29.2
3.03
35.6
28.4
3.35
33.5
27.6
3.70
31.3
35.1
28.2
3.02
33.2
27.4
3.34
31.2
26.6
3.69
29.0
35.1
35.1
3.02
33.5
33.5
3.34
31.8
31.8
3.69
30.0
35.1
35.1
3.02
33.5
33.5
3.34
31.8
31.8
3.69
30.0
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

18.3
24.1
23.3
28.7
28.7
19.0
25.4
24.5
29.4
29.4
19.8
26.7
25.7
30.0
30.0

4.00
3.98
3.96
3.96
3.96
4.05
4.03
4.01
4.02
4.02
4.10
4.08
4.06
4.07
4.07

31.0
28.3
26.3
26.8
26.8
31.2
28.5
26.5
27.4
27.4
31.3
28.7
26.7
28.0
27.9

17.4
23.2
22.3
26.8
26.8
18.1
24.5
23.5
27.4
27.4
18.9
25.7
24.6
28.0
27.9

Cooling

Indoor
Section

Size

Capacity

Power

Indoor
Section

Size

Capacity

Power

FX4ANF

042

1.00

1.00

CE3AA

042

0.97

1.00

F(A,B)4AN(F,B,C)

042

0.96

1.00

048

0.98

1.00

FC4BN(F,B)

042

0.96

1.00

042

0.97

1.00

FK4CNF

003

0.97

0.91

048

0.98

1.00

005

1.01

0.91

003

0.98

0.91

005

1.02

0.91

CJ5A/CK5A/CK5BW

048

0.98

1.00

042

0.99

1.00

CK3BA

042

0.97

1.00

—

—

048

0.98

1.00

FV4ANF
CC5A/CD5AA

—

CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BN

See notes on page 14.

—12—

042

0.97

1.00

048

0.98

1.00

4.40
4.38
4.36
4.37
4.37
4.46
4.43
4.41
4.42
4.42
4.51
4.48
4.46
4.48
4.48

DETAILED COOLING CAPACITIES* Continued
EVAP
AIR

CFM

EWB

75
Capacity
Total
MBtuh†
Sys
Total Sens‡ Kw**

CONDENSER ENTERING AIR TEMPERATURES °F
85
95
105
115
Capacity
Capacity
Capacity
Capacity
Total
Total
Total
Total
MBtuh†
MBtuh†
MBtuh†
MBtuh†
Sys
Sys
Sys
Sys
Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**

125
Capacity
Total
MBtuh†
Sys
Total Sens‡ Kw**

650AN042-A,C Outdoor Section With FV4ANF003 Indoor Section
1225

1400

1575

72
67
63††
62
57
72
67
63††
62
57
72
67
63††
62
57

48.5
44.6
41.7
41.0
39.7
49.4
45.4
42.5
41.9
41.2
50.0
46.0
43.1
42.7
42.4

24.4
30.9
30.1
37.2
39.7
25.6
32.9
32.0
39.7
41.2
26.7
34.7
33.7
41.9
42.4

2.95
2.91
2.89
2.88
2.87
2.99
2.96
2.93
2.93
2.92
3.04
3.00
2.98
2.97
2.97

46.4
23.6
3.32
44.1
22.8
3.72
41.7
21.9
4.17
39.0
42.6
30.1
3.28
40.5
29.2
3.68
38.3
28.3
4.12
35.8
39.8
29.3
3.25
37.8
28.4
3.65
35.7
27.5
4.09
33.4
39.2
36.3
3.24
37.3
35.3
3.65
35.3
34.3
4.09
33.2
38.2
38.2
3.24
36.7
36.7
3.64
35.0
35.0
4.08
33.1
47.1
24.8
3.36
44.8
23.9
3.77
42.2
23.1
4.22
39.5
43.3
32.0
3.32
41.2
31.2
3.73
38.8
30.2
4.17
36.3
40.5
31.1
3.30
38.4
30.2
3.70
36.2
29.3
4.14
33.9
40.0
38.7
3.29
38.2
37.6
3.70
36.2
36.2
4.14
34.2
39.6
39.6
3.29
37.9
37.9
3.69
36.1
36.1
4.14
34.2
47.7
25.9
3.41
45.3
25.1
3.81
42.7
24.2
4.26
39.9
43.9
33.9
3.37
41.6
33.0
3.77
39.3
32.1
4.22
36.7
41.0
32.8
3.34
38.9
31.9
3.74
36.7
31.0
4.19
34.3
40.9
40.7
3.34
39.0
39.0
3.74
37.1
37.1
4.19
35.1
40.8
40.8
3.34
39.0
39.0
3.74
37.1
37.1
4.19
35.1
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

21.0
27.4
26.5
33.0
33.1
22.1
29.3
28.3
34.2
34.2
23.2
31.1
29.9
35.1
35.1

4.65
4.61
4.57
4.57
4.57
4.70
4.65
4.62
4.62
4.62
4.74
4.70
4.66
4.68
4.68

36.1
33.2
31.0
31.1
31.1
36.5
33.6
31.3
32.0
32.0
36.8
33.9
31.6
32.8
32.8

20.0
26.3
25.5
31.1
31.1
21.1
28.2
27.2
32.0
32.0
22.2
29.9
28.8
32.8
32.8

5.17
5.12
5.09
5.09
5.09
5.22
5.17
5.14
5.15
5.15
5.26
5.22
5.18
5.20
5.20

Cooling

Indoor
Section

Size

Capacity

Power

Indoor
Section

Size

Capacity

Power

FV4ANF

003

1.00

1.00

CE3AA

048

1.00

1.08

F(A,B)4AN(F,B,C)

048

0.99

1.07

CJ5A/CK5A/CK5BA

048

0.99

1.08

FC4BN(F,B)

048

1.00

1.09

CJ5A/CK5A/CK5BN

048

0.99

1.08

FK4CNF

003

1.00

1.00

CJ5A/CK5A/CK5BW

048

0.99

1.08

005

1.01

0.98

CK3BA

048

0.99

1.08

FV4ANF

005

1.01

0.98

—

—

—

FX4ANF

042

1.00

1.09

650AN048-A,C Outdoor Section With FV4ANF005 Indoor Section
1400

1600

1800

72
67
63††
62
57
72
67
63††
62
57
72
67
63††
62
57

54.7
50.2
46.8
46.1
44.9
55.6
51.1
47.7
47.1
46.7
56.3
51.7
48.3
48.2
48.1

Indoor
Section
FV4ANF

27.7
35.2
34.3
42.5
44.9
29.1
37.5
36.5
45.5
46.7
30.4
39.7
38.5
48.1
48.1

3.20
3.16
3.13
3.12
3.11
3.26
3.22
3.19
3.18
3.18
3.32
3.28
3.24
3.24
3.24

52.2
26.8
3.56
49.6
25.9
3.96
46.9
24.9
4.41
43.9
47.9
34.3
3.52
45.5
33.3
3.92
43.0
32.3
4.36
40.3
44.7
33.3
3.49
42.4
32.4
3.89
40.1
31.3
4.33
37.6
44.0
41.5
3.48
42.0
40.5
3.88
39.7
39.3
4.33
37.5
43.2
43.2
3.47
41.4
41.4
3.88
39.6
39.6
4.33
37.5
53.0
28.1
3.62
50.3
27.2
4.02
47.4
26.2
4.47
44.4
48.7
36.6
3.58
46.2
35.6
3.98
43.6
34.6
4.42
40.8
45.4
35.5
3.55
43.1
34.5
3.95
40.7
33.5
4.39
38.1
45.1
44.4
3.54
42.9
42.9
3.95
41.0
41.0
4.39
38.8
44.8
44.8
3.54
42.9
42.9
3.94
40.9
40.9
4.39
38.8
53.6
29.4
3.68
50.8
28.5
4.08
47.9
27.5
4.53
44.8
49.3
38.8
3.64
46.7
37.8
4.04
44.1
36.8
4.48
41.2
46.0
37.5
3.60
43.6
36.5
4.00
41.1
35.5
4.45
38.5
46.2
46.2
3.61
44.2
44.2
4.01
42.1
42.1
4.46
39.8
46.2
46.2
3.60
44.2
44.2
4.01
42.1
42.1
4.46
39.8
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

Size
005

Capacity
1.00

Power
1.00

Indoor
Section
FX4ANF

23.9
31.3
30.3
37.5
37.5
25.2
33.5
32.4
38.8
38.8
26.5
35.7
34.4
39.8
39.8

4.90
4.85
4.82
4.82
4.82
4.96
4.91
4.88
4.89
4.89
5.01
4.97
4.94
4.95
4.95

40.7
37.4
34.9
35.2
35.2
41.1
37.8
35.3
36.3
36.4
41.4
38.2
35.7
37.3
37.3

22.8
30.1
29.1
35.2
35.2
24.1
32.3
31.2
36.3
36.4
25.4
34.4
33.1
37.3
37.3

Cooling
Size
048

Capacity
0.99

Power
1.06

F(A,B)4AN(F,B,C)

060

0.98

1.10

FX4ANB

060

1.00

1.06

FB4ANB

070

1.01

1.06

CE3AA

060

1.00

1.06

FC4BN(F,B)

060

0.98

1.10

CJ5A/CK5A/CK5BA

060

0.99

1.06

FC4BNB

070

1.01

1.06

CJ5A/CK5A/CK5BN

060

1.00

1.06

FK4CNB

006

1.02

0.98

CJ5A/CK5A/CK5BX

060

1.00

1.06

FK4CNF

005

1.00

1.00

CK3BA

060

0.99

1.06

FV4ANB

006

1.02

0.98

—

—

—

See notes on page 14.

—13—

5.43
5.39
5.36
5.37
5.37
5.49
5.45
5.42
5.43
5.43
5.55
5.51
5.48
5.50
5.50

DETAILED COOLING CAPACITIES* Continued
EVAP
AIR

CFM

EWB

75
Capacity
Total
MBtuh†
Sys
Total Sens‡ Kw**

CONDENSER ENTERING AIR TEMPERATURES °F
85
95
105
115
Capacity
Capacity
Capacity
Capacity
Total
Total
Total
Total
MBtuh†
MBtuh†
MBtuh†
MBtuh†
Sys
Sys
Sys
Sys
Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw**

125
Capacity
Total
MBtuh†
Sys
Total Sens‡ Kw**

650AN060-B,C Outdoor Section With FV4ANB006 Indoor Section
1750

2000

2250

72
67
63††
62
57
72
67
63††
62
57
72
67
63††
62
57

70.1
64.4
60.2
59.2
57.8
71.1
65.5
61.2
60.5
60.1
72.0
66.2
61.9
61.8
61.8

35.6
45.5
44.3
55.1
57.8
37.4
48.5
47.1
59.0
60.1
39.1
51.4
49.8
61.8
61.8

4.43
4.35
4.30
4.29
4.27
4.52
4.44
4.39
4.38
4.38
4.61
4.53
4.48
4.48
4.48

66.6
34.4
4.92
63.1
33.1
5.47
59.2
31.7
6.07
55.0
61.3
44.2
4.85
58.0
42.9
5.40
54.5
41.5
6.00
50.6
57.2
43.0
4.79
54.2
41.7
5.34
50.9
40.3
5.94
47.3
56.4
53.7
4.78
53.5
52.3
5.33
50.5
50.4
5.93
47.5
55.6
55.6
4.77
53.1
53.1
5.32
50.5
50.5
5.93
47.5
67.6
36.1
5.02
63.9
34.8
5.57
59.8
33.4
6.16
55.5
62.2
47.2
4.94
58.8
45.9
5.49
55.1
44.4
6.09
51.1
58.1
45.8
4.88
54.9
44.4
5.43
51.6
43.0
6.03
47.9
57.7
57.4
4.88
54.9
54.9
5.43
52.1
52.1
6.04
48.9
57.6
57.6
4.88
54.9
54.9
5.43
52.1
52.1
6.04
49.0
68.3
37.8
5.10
64.4
36.5
5.65
60.4
35.1
6.25
55.9
62.9
50.1
5.03
59.4
48.7
5.57
55.6
47.3
6.17
51.7
58.8
48.5
4.97
55.6
47.1
5.52
52.1
45.6
6.12
48.3
59.2
59.2
4.98
56.5
56.5
5.53
53.5
53.5
6.14
50.2
59.2
59.2
4.98
56.4
56.4
5.53
53.4
53.4
6.14
50.2
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

Indoor
Section
FV4ANB

Size
006

Capacity
1.00

Power
1.00

30.3
40.0
38.8
47.5
47.5
32.0
42.9
41.5
48.9
49.0
33.7
45.7
44.0
50.2
50.2

6.73
6.65
6.60
6.60
6.60
6.81
6.74
6.68
6.70
6.70
6.90
6.83
6.77
6.80
6.80

50.2
46.4
43.4
44.2
44.2
50.6
46.8
43.8
45.3
45.4
50.8
47.1
44.1
46.4
46.4

28.7
38.4
37.1
44.2
44.2
30.4
41.2
39.7
45.3
45.4
32.0
43.9
42.1
46.4
46.4

7.42
7.35
7.30
7.32
7.32
7.51
7.44
7.39
7.42
7.42
7.59
7.53
7.48
7.51
7.51

Cooling

Indoor
Section
FX4ANB

Size
060

Capacity
0.98

Power
1.04

FB4ANB

070

0.98

1.04

CC5A/CD5AW

060

0.97

0.99

FC4BNB

070

0.98

1.04

CJ5A/CK5A/CK5BX

060

0.97

1.00

FK4CNB

006

1.00

1.00

—

—

—

* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C).
** System kw is total of indoor and outdoor unit kilowatts.
†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.
EWB—Entering Wet Bulb

—14—

HEAT PUMP HEATING PERFORMANCE
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3
7
17
27
37
47
57
67
Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total
MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr
CFM Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†

INDOOR
AIR

EDB

650AN024-A,C Outdoor Section With FX4ANF030 Indoor Section
65
70
75

700
800
900
700
800
900
700
800
900

12.0
12.2
12.4
11.8
12.0
12.1
11.5
11.7
11.8

11.1
11.2
11.4
10.8
11.0
11.2
10.6
10.7
10.9

1.79
1.80
1.82
1.87
1.88
1.90
1.96
1.97
1.98

14.3
14.5
14.6
14.1
14.3
14.4
13.9
14.1
14.3

13.1 1.87 16.6 15.1 1.95 19.0 16.9 2.04 21.9 19.9 2.16 25.0 25.0
13.3 1.87 16.8 15.3 1.95 19.2 17.1 2.03 22.1 20.1 2.13 25.4 25.4
13.4 1.88 17.0 15.5 1.95 19.4 17.3 2.03 22.4 20.4 2.13 25.6 25.6
13.0 1.96 16.4 15.0 2.05 18.8 16.7 2.14 21.6 19.6 2.26 24.7 24.7
13.1 1.96 16.6 15.1 2.04 19.0 16.9 2.13 21.8 19.9 2.24 25.0 25.0
13.3 1.97 16.8 15.3 2.05 19.2 17.0 2.13 22.1 20.1 2.23 25.3 25.3
12.8 2.05 16.2 14.8 2.15 18.5 16.5 2.25 21.3 19.4 2.38 24.3 24.3
13.0 2.06 16.4 15.0 2.14 18.8 16.7 2.23 21.5 19.6 2.35 24.6 24.6
13.1 2.07 16.6 15.1 2.15 19.0 16.8 2.23 21.8 19.8 2.34 24.9 24.9
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

Indoor
Section
FX4ANF

Size
030

Capacity
1.00

Power
1.00

2.30
2.27
2.25
2.41
2.38
2.36
2.53
2.50
2.48

28.5
28.9
29.3
28.1
28.5
28.8
27.7
28.1
28.4

28.5
28.9
29.3
28.1
28.5
28.8
27.7
28.1
28.4

2.48
2.44
2.43
2.60
2.56
2.54
2.73
2.68
2.66

32.6
33.1
33.4
32.0
32.5
32.9
31.5
32.0
32.4

32.6
33.1
33.4
32.0
32.5
32.9
31.5
32.0
32.4

Cooling

Indoor
Section
CE3AA

Size
030
036

0.98

1.01

CJ5A/CK5A/CK5BA

030

0.98

1.01

Capacity
0.98

Power
1.01

F(A,B)4AN(F,C)

030

0.98

1.01

FC4BNF

030

0.98

1.01

FK4CNF

001

0.95

0.95

036

0.99

0.98

002

1.00

0.92

CJ5A/CK5A/CK5BN

036

0.99

0.98

003

1.01

0.94

CJ5A/CK5A/CK5BW

030

0.98

1.01

002

1.01

0.97

036

0.99

0.98

003

1.00

0.96

—

—

FV4ANF

—

CK3BA

2.74
2.69
2.67
2.87
2.81
2.79
3.00
2.94
2.91

030

0.98

1.01

036

0.99

0.98

650AN030-A,C Outdoor Section With FX4ANF030 Indoor Section
65
70
75

825
1050
1250
825
1050
1250
825
1050
1250

12.6
12.9
13.2
12.3
12.7
13.0
12.0
12.4
12.7

11.6
11.9
12.2
11.3
11.7
11.9
11.1
11.4
11.7

Indoor
Section
FX4ANF
F(A,B)4AN(F,C)
FC4BNF
FK4CNF

2.07
2.11
2.15
2.18
2.21
2.25
2.29
2.32
2.36

15.4
15.7
16.0
15.2
15.6
15.8
15.0
15.3
15.6

14.1 2.12 18.3 16.7 2.16 21.6 19.2 2.22 25.4 23.1 2.29 29.7 29.7
14.4 2.14 18.7 17.0 2.17 22.0 19.6 2.21 25.9 23.6 2.27 30.4 30.4
14.7 2.17 19.0 17.3 2.19 22.4 19.9 2.23 26.3 23.9 2.28 30.8 30.8
14.0 2.23 18.1 16.5 2.28 21.4 19.0 2.33 25.1 22.8 2.41 29.4 29.4
14.3 2.25 18.5 16.9 2.28 21.8 19.4 2.32 25.6 23.3 2.38 30.0 30.0
14.5 2.28 18.8 17.1 2.30 22.1 19.6 2.34 26.0 23.6 2.39 30.4 30.4
13.7 2.34 18.0 16.4 2.40 21.1 18.8 2.46 24.8 22.6 2.54 29.0 29.0
14.1 2.35 18.3 16.7 2.40 21.6 19.1 2.44 25.3 23.0 2.50 29.6 29.6
14.4 2.39 18.6 17.0 2.42 21.9 19.4 2.45 25.7 23.4 2.51 30.0 30.0
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

Size
030

Capacity
1.00

Power
1.00

2.39
2.35
2.36
2.52
2.47
2.47
2.65
2.59
2.59

34.6
35.4
36.0
34.1
34.9
35.4
33.7
34.4
34.9

34.6
35.4
36.0
34.1
34.9
35.4
33.7
34.4
34.9

2.69
2.63
2.64
2.82
2.76
2.76
2.96
2.89
2.89

32.7
33.5
33.9
32.2
33.0
33.4
31.7
32.5
33.0

32.7
33.5
33.9
32.2
33.0
33.4
31.7
32.5
33.0

Cooling

Indoor
Section
FV4ANF

Size
002
003

0.95

0.92

FX4ANF

036

1.00

1.01

Capacity
0.97

Power
0.94

030

0.98

1.02

036

0.99

1.03

030

0.98

1.02

CE3AA

036

0.97

1.01

036

0.99

1.03

CJ5A/CK5A/CK5BN

036

0.98

0.99

001

0.95

0.96

CJ5A/CK5A/CK5BW

036

0.98

0.98

002

0.97

0.94

CK3BA

036

0.98

0.98

003

0.95

0.92

—

—

—

See notes on page 17.

—15—

2.55
2.49
2.49
2.67
2.60
2.60
2.80
2.72
2.71

HEAT PUMP HEATING PERFORMANCE Continued
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3
7
17
27
37
47
57
67
Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total
MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr
CFM Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†

INDOOR
AIR

EDB

650AN036-A,C Outdoor Section With FX4ANF042 Indoor Section
65
70
75

1125
1250
1375
1125
1250
1375
1125
1250
1375

14.7
14.9
15.1
14.1
14.4
14.6
13.5
13.8
14.0

13.5
13.7
13.9
13.0
13.2
13.4
12.4
12.7
12.9

2.42
2.45
2.49
2.51
2.54
2.58
2.60
2.63
2.67

18.3
18.5
18.7
17.9
18.1
18.4
17.4
17.7
17.9

16.8 2.51 21.9 20.0 2.59 25.8 22.9 2.66 30.4 27.6 2.76 35.6 35.6
17.0 2.53 22.9 20.9 2.61 26.1 23.2 2.67 30.7 27.9 2.76 35.9 35.9
17.2 2.56 22.4 20.4 2.62 26.3 23.4 2.68 31.0 28.2 2.76 36.3 36.3
16.4 2.61 21.6 19.7 2.70 25.4 22.6 2.79 29.9 27.2 2.89 35.0 35.0
16.7 2.63 21.9 19.9 2.72 25.7 22.8 2.79 30.2 27.5 2.89 35.4 35.4
16.9 2.66 22.1 20.1 2.74 26.0 23.1 2.81 30.5 27.8 2.89 35.7 35.7
16.0 2.71 21.2 19.4 2.82 25.0 22.2 2.92 29.5 26.8 3.03 34.5 34.5
16.2 2.74 21.5 19.6 2.84 25.3 22.5 2.92 29.8 27.1 3.02 34.8 34.8
16.4 2.76 21.7 19.8 2.86 25.6 22.7 2.93 30.1 27.4 3.03 35.2 35.2
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

41.7
42.1
42.5
41.5
41.5
41.8
40.3
40.8
41.2

41.7
42.1
42.5
41.5
41.5
41.8
40.3
40.8
41.2

3.04
3.03
3.03
3.19
3.17
3.16
3.34
3.31
3.31

48.8
49.3
49.7
48.0
48.5
48.9
47.1
47.7
48.1

48.8
49.3
49.7
48.0
48.5
48.9
47.1
47.7
48.1

Size
042

Capacity
1.00

Power
1.00

F(A,B)4AN(F,B,C)

042

0.98

1.02

FC4BN(F,B)

042

0.98

1.02

FK4CNF

003

0.96

0.96

005

0.97

0.89

CJ5A/CK5A/CK5BW

048

0.98

1.01

003

0.96

0.95

CK3BA

042

0.98

1.02

005

0.97

0.89

048

0.98

1.01

042

0.98

1.02

—

—

—

048

0.98

1.01

CE3AA

CJ5A/CK5A/CK5BN

3.27
3.25
3.25
3.42
3.40
3.39
3.58
3.55
3.54

Cooling

Indoor
Section
FX4ANF

FV4ANF

Indoor
Section
CJ5A/CK5A/CK5BA

2.88
2.87
2.87
3.02
3.00
3.00
3.16
3.15
3.15

Size
042

Capacity
0.98

Power
1.02

048

0.98

1.01

042

0.98

1.02

048

0.98

1.01

650AN042-A,C Outdoor Section With FV4ANF003 Indoor Section
65
70
75

1225
1400
1575
1225
1400
1575
1225
1400
1575

17.3
17.6
17.8
16.8
17.1
17.3
16.3
16.6
16.8

15.9
16.2
16.4
15.5
15.7
15.9
15.0
15.2
15.4

2.61
2.61
2.62
2.74
2.75
2.76
2.88
2.89
2.90

21.5
22.5
21.9
21.1
21.4
21.6
20.6
20.9
21.2

19.8 2.74 25.7 23.4 2.86 30.0 26.6 2.99 35.1 32.0 3.14 41.1 41.1
20.7 2.74 25.9 23.6 2.84 30.2 26.9 2.95 35.5 32.3 3.09 41.5 41.5
20.2 2.73 26.1 23.8 2.83 30.5 27.1 2.93 35.8 32.6 3.06 41.9 41.9
19.4 2.88 25.4 23.2 3.03 29.6 26.3 3.16 34.7 31.6 3.32 40.5 40.5
19.6 2.87 25.6 23.4 3.00 29.9 26.6 3.12 35.0 31.9 3.27 41.0 41.0
19.8 2.87 25.8 23.6 2.99 30.1 26.8 3.10 35.3 32.2 3.24 41.3 41.3
19.0 3.02 25.1 22.9 3.19 29.3 26.0 3.34 34.3 31.2 3.51 40.0 40.0
19.2 3.01 25.3 23.1 3.17 29.6 26.3 3.30 34.6 31.5 3.46 40.4 40.4
19.4 3.01 25.5 23.3 3.16 29.8 26.5 3.28 34.9 31.8 3.42 40.8 40.8
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

Indoor
Section
FV4ANF

Size
003

Capacity
1.00

Power
1.00

F(A,B)4AN(F,B,C)

048

1.02

FC4BN(F,B)

048

1.02

FK4CNF

003

FV4ANF

3.34
3.28
3.24
3.53
3.46
3.42
3.73
3.66
3.61

40.4
40.8
41.2
39.8
40.2
40.6
39.2
39.6
40.0

40.4
40.8
41.2
39.8
40.2
40.6
39.2
39.6
40.0

3.30
3.22
3.18
3.48
3.40
3.35
3.66
3.58
3.53

39.5
40.0
40.4
38.9
39.4
39.8
38.3
38.8
39.1

39.5
40.0
40.4
38.9
39.4
39.8
38.3
38.8
39.1

Cooling

Indoor
Section
FX4ANF

Size
042

Capacity
1.02

Power
1.01

1.03

CE3AA

048

1.02

1.04

1.02

CJ5A/CK5A/CK5BA

048

1.02

1.03

0.99

1.00

CJ5A/CK5A/CK5BN

048

1.02

1.03

005

0.99

0.93

CJ5A/CK5A/CK5BW

048

1.02

1.03

005

0.99

0.93

CK3BA

048

1.02

1.03

See notes on page 17.

—16—

3.21
3.14
3.09
3.38
3.30
3.25
3.56
3.47
3.41

HEAT PUMP HEATING PERFORMANCE Continued
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3
7
17
27
37
47
57
67
Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total
MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr MBtuh† Pwr
CFM Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†

INDOOR
AIR

EDB

650AN048-A,C Outdoor Section With FV4ANF005 Indoor Section
65
70
75

1400
1600
1800
1400
1600
1800
1400
1600
1800

18.5
18.7
18.9
18.1
18.4
18.6
17.7
18.0
18.2

17.0
17.2
17.4
16.7
16.9
17.1
16.3
16.6
16.8

2.86
2.87
2.89
3.03
3.03
3.05
3.19
3.20
3.22

22.9
23.2
23.4
22.7
23.0
23.2
22.4
22.7
22.9

21.1 2.99 27.9 25.4 3.11 33.5 29.8 3.26 40.2 36.6 3.45 48.2 48.2
21.3 2.98 28.1 25.6 3.10 33.8 30.1 3.23 40.7 37.0 3.41 48.7 48.7
21.5 2.99 28.4 25.9 3.10 34.1 30.3 3.23 41.0 37.3 3.40 49.1 49.1
20.9 3.16 27.6 25.2 3.29 33.2 29.4 3.44 39.8 36.2 3.64 47.5 47.5
21.1 3.15 27.8 25.4 3.27 33.5 29.7 3.41 40.2 36.5 3.60 48.0 48.0
21.3 3.16 28.1 25.6 3.27 33.8 30.0 3.41 40.5 36.9 3.58 48.4 48.4
20.6 3.33 27.4 24.9 3.48 32.8 29.2 3.64 39.3 35.7 3.84 46.8 46.8
20.9 3.33 27.6 25.2 3.46 33.1 29.4 3.60 39.7 36.1 3.79 47.4 47.4
21.1 3.33 27.8 25.4 3.45 33.4 29.7 3.59 40.0 36.4 3.77 47.8 47.8
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

Indoor
Section
FV4ANF

Size
005

Capacity
1.00

Power
1.00

Indoor
Section
FX4ANB

3.69
3.64
3.63
3.89
3.83
3.81
4.09
4.04
4.01

53.8
54.4
54.9
54.3
53.6
54.1
52.2
52.8
53.3

53.8
54.4
54.9
54.3
53.6
54.1
52.2
52.8
53.3

4.34
4.28
4.26
4.57
4.50
4.47
4.80
4.72
4.69

53.1
53.7
54.1
52.3
52.9
53.3
51.4
52.0
52.5

53.1
53.7
54.1
52.3
52.9
53.3
51.4
52.0
52.5

4.20
4.14
4.12
4.40
4.33
4.31
4.62
4.54
4.51

Cooling
Size
060

Capacity
1.01

Power
1.02

F(A,B)4AN(F,B,C)

060

1.02

1.10

FX4ANF

048

1.01

1.06

FB4ANB

070

1.01

1.02

CE3AA

060

1.01

1.06

FC4BN(F,B)

060

1.01

1.09

CJ5A/CK5A/CK5BA

060

1.01

1.03

FC4BNB

070

1.01

1.02

CJ5A/CK5A/CK5BN

060

1.02

1.04

FK4CNB

006

1.01

0.96

CJ5A/CK5A/CK5BX

060

1.02

1.04

FK4CNF

005

1.01

1.01

CK3BA

060

1.01

1.03

FV4ANB

006

1.01

0.96

—

—

—

650AN060-B,C Outdoor Section With FV4ANB006 Indoor Section
65
70
75

1750
2000
2250
1750
2000
2250
1750
2000
2250

24.4
24.9
25.3
23.4
23.8
24.3
22.2
22.7
23.2

22.4
22.9
23.3
21.5
21.9
22.3
20.5
20.9
21.3

3.73
3.76
3.80
3.92
3.95
4.00
4.12
4.15
4.20

30.9
31.5
31.9
30.0
30.5
31.0
28.9
29.5
30.0

28.4 3.88 37.9 34.6 4.05 45.0 40.0 4.24 52.6 47.9 4.45 60.8 60.8
28.9 3.90 38.5 35.1 4.05 45.7 40.6 4.22 53.2 48.4 4.41 61.6 61.6
29.3 3.93 39.0 35.5 4.06 46.2 41.0 4.23 53.7 48.9 4.39 62.2 62.2
27.6 4.09 37.0 33.7 4.27 44.2 39.2 4.46 52.0 47.3 4.70 60.0 60.0
28.0 4.10 37.6 34.3 4.26 44.8 39.8 4.44 52.5 47.8 4.65 60.7 60.7
28.5 4.13 38.1 34.7 4.28 45.4 40.3 4.45 53.1 48.3 4.63 61.4 61.4
26.6 4.30 36.0 32.9 4.49 43.2 38.4 4.70 51.3 46.7 4.96 59.2 59.2
27.1 4.31 36.7 33.4 4.49 43.9 39.0 4.67 51.9 47.2 4.90 59.9 59.9
27.5 4.34 37.2 33.9 4.50 44.5 39.5 4.67 52.4 47.7 4.88 60.6 60.6
Multipliers for Determining the Performance With Other Indoor Sections
Cooling

Indoor
Section
FV4ANB

Size
006

Capacity
1.00

Power
1.00

4.68
4.61
4.58
4.94
4.87
4.83
5.21
5.13
5.09

58.2
59.0
59.6
57.4
58.1
58.8
56.5
57.3
57.9

58.2
59.0
59.6
57.4
58.1
58.8
56.5
57.3
57.9

4.52
4.44
4.39
4.76
4.67
4.62
5.02
4.92
4.86

56.3
57.1
57.8
55.4
56.2
56.9
54.5
55.3
56.0

56.3
57.1
57.8
55.4
56.2
56.9
54.5
55.3
56.0

4.47
4.37
4.31
4.71
4.60
4.53
4.95
4.83
4.76

Cooling

Indoor
Section
FX4ANB

Size
060

Capacity
1.00

Power
1.03

FB4ANB

070

1.00

1.03

CC5A/CD5AW

060

0.98

1.06

FC4BNB

070

1.00

1.03

CJ5A/CK5A/CK5BX

060

0.98

1.02

FK4CNB

006

0.99

0.99

—

–

—

* The Btuh heating capacity values shown are net “integrated” values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
† The kw values include the compressor, outdoor fan motor, and indoor blower motor. The kw from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB—Entering Dry Bulb

NOTE: The performance shown includes the PressureGuard™ cycling the outdoor fan. The ambient temperature that the
outdoor fan cycles depends on the outdoor/indoor combination, indoor airflow, installation practices, and system maintenance, all of which affect system performance.

—17—

System Design
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.

Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
Minimum outdoor operating air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
Maximum outdoor operating air temperature for cooling mode is 125°F (51.7°C).
Minimum outdoor operating air temperature for heating mode is –30°F (–34.4°C).
Maximum outdoor operating air temperature for heating mode is 66°F (18.9°C).
For reliable operation, unit should be level in all horizontal planes.
Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft. (See items 8 and
9 following).
For interconnecting refrigerant tube lengths greater than 50 ft and/or elevation differences between indoor and outdoor units greater than 20 ft, consult Residential Split-System Application Guideline and Service Manual for Air Conditioners and Heat Pumps using Puron Refrigerant.
If ANY refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36-in.
may be buried without further considerations. Buried refrigerant tubing lengths greater than 36 in. are not recommended.
Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
Mixmatches of indoor coil capacity more than 1 size larger than outdoor unit capacity (unless so specified) may result in inadequate indoor comfort.
Do not apply capillary tube indoor coils to these units.
Factory-supplied filter drier must be installed.

MATCHED SYSTEM

HEAT PUMP

VENTILATOR PLUS
ZONE PERFECT PLUS ™
EQUIPMENT CONTROLLER
FAN COIL

HUMIDIFIER

AIR CLEANER

A98536

—18—

—19—

SERVICE TRAINING
Packaged Service Training programs are an excellent way to increase your
knowledge of the equipment discussed in this manual, including:
• Unit Familiarization
• Maintenance
• Installation Overview
• Operating Sequence
A large selection of product, theory, and skills programs is available, using popular
video-based formats and materials. All include video and/or slides, plus companion
book.
Classroom Service Training plus "hands-on" the products in our labs can mean
increased confidence that really pays dividends in faster troubleshooting, fewer
callbacks. Course descriptions and schedules are in our catalog.
CALL FOR FREE CATALOG 1-800-962-9212
[ ] Packaged Service Training

[ ] Classroom Service Training
A94328

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS

Cancels: PDS 650A.24.1

© 1998 Bryant Heating & Cooling Systems, 7310 W. Morris St.

Indianapolis, IN 46231

—20—

PRINTED IN U.S.A.

Catalog No. 5265-002

1-99



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Create Date                     : 1999:02:02 11:11:49Z
Modify Date                     : 2005:11:14 11:50:02-05:00
Metadata Date                   : 2005:11:14 11:50:02-05:00
Producer                        : Acrobat Distiller 2.0 for Windows
Keywords                        : 
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : Carrier Corporation
Subject                         : 
Document ID                     : uuid:d58a33b3-c605-4116-874d-4a1ab6090b77
Instance ID                     : uuid:1a726915-2b6a-4a3b-83e5-050343d86999
Page Count                      : 20
Author                          : Carrier Corporation
EXIF Metadata provided by EXIF.tools

Navigation menu