Buddy Platform SENSE100 Ohm Sense 100 User Manual Buddy OHM x

Buddy Platform, Inc. Ohm Sense 100 Buddy OHM x

2ALECSENSE100_User Manual_0519

Download: Buddy Platform SENSE100 Ohm Sense 100 User Manual Buddy OHM x
Mirror Download [FCC.gov]Buddy Platform SENSE100 Ohm Sense 100 User Manual Buddy OHM x
Document ID3400870
Application IDY3f5ufQspf4qL+Ia+ob3gA==
Document Description2ALECSENSE100_User Manual_0519
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize19.33kB (241645 bits)
Date Submitted2017-05-23 00:00:00
Date Available2017-05-24 00:00:00
Creation Date2017-05-10 17:37:13
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2017-05-10 17:44:39
Document TitleMicrosoft Word - Buddy OHM User Manual.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: Kate.Lai

Buddy OHM User Manual
Overview
The Buddy OHM system has the capability to monitor electrical energy use / generation,
temperature and humidity.
The system is made up of five main units. These can be assembled and configured to work for
a variety of applications. The system is fully open-source, both hardware and software. All
hardware is based on the Arduino and Raspberry Pi platforms.
The hardware options to set up a home energy monitor are as follows
The Buddy OHM is an all-in-one Raspberry Pi based energy monitoring unit making for a
simple installation where Ethernet or 3G dongle is available at the meter location.
The Buddy OHM can monitor two single-phase AC circuits using clip-on CT sensors. The
Buddy OHM can also monitor temperature, and interface directly with utility meters via an
optical pulse sensor.

Raspberry Pi-based energy monitor

Install next to utility meter

Local & remote data logging with Buddy cloud , our open-source web-app for
processing, logging and visualising energy and other environmental data, such as
humidity and temperature

Requires 3G dongle

Requires pre-built SD card image (included)
Sensors Required:

1 X Clip-on CT sensors (can accept up to two CT sensors; one is included as standard
with the Buddy OHM)

1 x AC-AC voltage sensor adapter (optional but highly recommended)
Power Adapters Required: 1 x USB 5V DC
OHM Link
The OHM Link is a remote sensor node. Data is transmitted to an Buddy OHM via a low
power 434MHz radio.
The OHM Link can monitor up to four single-phase AC circuits using clip-on CT sensors. A
plug-in AC-AC adapter can be used to power the unit and provide an AC voltage sample for
real-power calculations. 3 x AA batteries can be used to power the OHM Link, if AC power is
not available.

Energy monitoring add-on node

Optional add-on if more then two circuits need to be monitored.

RF Range is approximately similar to home WiFi and can be affected by obstacles e.g.
thick stone walls

Up to 2x OHM Link can be connected to a single Buddy OHM
OHM Pulse

Optional add-on sensor for interfacing directly with utility meters

Compatible with all utility meters with LED pulse output

Compatible with Buddy OHM&OHM Link

Reports exact amount of energy (Wh) reported by utility meter

Cannot measure instantaneous power

Best used in conjunction with clip-on CT sensor(s)
(one pulse sensor per unit)
OHM Link
1. Microcontroller: ATmega328p
2. Internal Sensor: Si7021 (internal temperature & Humidity)
3. Power: 2 x AA from onboard holder, LTC3525 3.3V DC-DC boost converter to
extend battery life
4. RF Radio: RFM69CW 434Mhz
Si7021 Temperature & Humidity Sensor
1. Silicon Labs SI7021-A20-GM1R
2. Power supply 1.9V - 3.6V
3. Operating range humidity 0-80%RH; temperature -40~125℃
4. Accuracy humidity +-3%RH
5. Accuracy Temperature: +-0.4℃
6. Active current: 150uA
7. Sleep current 0.06uA
Installation
CT sensor
1.
Clip the CT sensor around either the Live or Neutral cable
2.
Connect jack plug into either CT1 or CT2 socket on the Buddy OHM
3.
If the power reading is negative, reverse the CT sensor orientation
4.
CT sensor cable should not be extended to avoid induced noise
AC-AC Adapter
1. Plug the AC-AC adapter into a power outlet
2. This may require installation of a new outlet or extending an existing one
3. AC-AC adapter cable can be extended if required
4. Plug power connector into the AC socket on the Buddy OHM
5. Provides AC waveform reference for accurate Real Power measurements.
DC 5V USB Adapter
1. Plug the DC 5V USB adapter into a power outlet
2. Plug the mini-B USB connector into the Buddy OHM
3. High quality minimum 2.5A power supply recommended
OHM Pulse Sensor
1. Connects to OHM / OHM Link via RJ45 connector
2. Self-adhesive velcro attachment to utility meter
3. One optical pulse sensor per OHM/ OHM Link
4. Can be used in conjunction with temperature sensors using RJ45 Breakout
OHM Sense
OHM Sense is wireless temperature & humidity sensor.
Data from the OHM Sense is
transmitted via wireless RF (434MHz) to Buddy OHMweb-connected base-station
for logging to BUDDY Cloud for data logging, processing and graphing.
Power Up
1. Switch on DC & AC power
2. Check CT sensor(s) & AC Wave are detected:
3. Buddy Ohm should remember 3G network and re-connect
Hardware Specification
Attribute
Parameter
Accuracy
>89%
Measuring Current (CT)
50mA-96A
Measuring Voltage (AC-AC)
110VAC-254VAC
Sample period
5s
Frequency
434Mhz
RF range
100m
Power Consumption
400-800mA RasPi3
Embodied Energy
40KWh
Operating temperature
-25 to +80℃
Physical Dimensions
19cm x 3.5cm x 19cm
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful interference in a residential installation.
This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate this equipment.
Canada, Industrie Canada (IC)
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de classe B est conforme à la norme NMB-003.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables auxappar
eils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage adioélectrique subi, même si
le brouillage est susceptible d'en compromettre le fonctionnement.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : Kate.Lai
Create Date                     : 2017:05:10 17:37:13+08:00
Modify Date                     : 2017:05:10 17:44:39+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Title                           : Microsoft Word - Buddy OHM User Manual.docx
Creator                         : Kate.Lai
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:05:10 17:44:39+08:00
Producer                        : Acrobat Distiller 9.3.3 (Windows)
Document ID                     : uuid:4eb142c2-3792-4f7f-ad38-5ccdd385ae32
Instance ID                     : uuid:7625d4dc-210e-41c6-a9f9-eb4182beeb4b
Page Count                      : 7
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ALECSENSE100

Navigation menu