Bunn Water Heater Dv Pc Users Manual 39338.0001B
Bunn Water Heater DV PC 39338.0001
DV PC to the manual ed286e87-4445-4f6f-99ef-ff7d6b7181ac
2015-02-04
: Bunn Bunn-Bunn-Water-Heater-Dv-Pc-Users-Manual-364323 bunn-bunn-water-heater-dv-pc-users-manual-364323 bunn pdf
Open the PDF directly: View PDF .
Page Count: 9
Download | |
Open PDF In Browser | View PDF |
H10X/H5X H5E/DV PC With Digital Control Board Supercedes: 10420.0001; 10889.0001; 39338.0000 INSTALLATION & OPERATING GUIDE BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and manual updates. Contact Bunn-O-Matic Corporation at 1-800-286-6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service. 39338.0001B 09/10 © 2009 BUNN-O-MATIC CORPORATION BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor. 4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first. These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty. THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon. If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment. THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages. 392, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, BrewWISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, A Partner You Can Count On, Air Brew, Air Infusion, Beverage Bar Creator, Beverage Profit Calculator, Brew better, not bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Digital Brewer Control, Nothing Brews Like a BUNN, Pouring Profits, Signature Series, Tea At Its Best, Phase Brew, The Horizontal Red Line, Titan, trifecta, Ultra, Velocity Brew are either trademarks or registered trademarks of Bunn-O-Matic Corporation. 2 39338.1 051910 CONTENTS Warranty .......................................................2 Introduction ..................................................3 User Notices .................................................3 Electrical Requirements ................................4 Plumbing Requirements ...............................5 Initial Set-Up .................................................5 Programming ................................................6 Draining the Dispenser..................................8 Cleaning ........................................................8 INTRODUCTION This equipment heats and dispenses water on demand for beverages and cooking purposes. It has a panel above the faucet that indicates the status of the dispenser. This equipment is for indoor use, either wall-mounted (H5E/H5X/H5-PC only) or on a sturdy counter or shelf. USER NOTICES The notices on this dispenser should be kept in good condition. Replace unreadable or damaged labels. This equipment must be installed to comply with the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A., comply with the applicable Plumbing /Sanitation Code. 00656.0000 ! WARNING Fill water tank before turning - on thermostat or connecting appliance to power source. Use only on a properly protected circuit capable of the rated load. Electrically ground the chassis. Follow national/local electrical codes. Do not use near combustibles. 120V 120/208-240V 00831.0000 FAILURE TO COMPLY RISKS EQUIPMENT DAMAGE, FIRE, OR SHOCK HAZARD READ THE ENTIRE OPERATING MANUAL BEFORE BUYING OR USING THIS PRODUCT THIS APPLIANCE IS HEATED WHENEVER CONNECTED TO A POWER SOURCE 00831.0000F 3/98 ©1998 BUNN-O-MATIC CORPORATION 00831.0000 To reduce the risk of electric shock, do not remove or open cover. No user-serviceable parts inside. Authorized service personnel only. Disconnect power before servicing. 37881.0000 120 V, 15.4 A, 1850 W 1PH, 2-Wire + GND, 60HZ NOTICE ALL COMPONENTS ARE 200 TO 240 VOLT A.C. 29710.0000 Replace only with components listed in the accompaning literature rated for the same voltage 12537.0000 ! WARNING Hot Water Use With Care 12593.0000 Optional Field Wiring Optional Field Wiring 120/208-240 V, 16.9 A, 4050 W 1PH, 3-Wire + GND, 60HZ 00824.0000 00824.0001 3 29710.0000 39338.1.1 072409 ELECTRICAL REQUIREMENTS WARNING - The dispenser must be disconnected from the power source until specified in Initial Set-Up. Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements. WHITE NEUTRAL L1 BLACK NEUTRAL WHITE N L1 BLACK POWER CORD L2 RED L1 L1 BROWN GREEN G 120 volt ac models Note: This electrical service consists of 2 current carrying conductors (L1 and Neutral) and a separate conductor for earth ground. POWER CORD NEUTRAL BLUE N L1 BLACK L2 RED L1 POWER CORD L2 RED L2 L1 BLACK L1 BLACK L1 GREEN/YELLOW GREEN G G 208 & 240 volt ac models 230 volt ac models Note: This electrical service consists of 2 current carrying conductors (L1 and Neutral) and a separate conductor for earth ground. Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components. 1. An electrician must provide electrical service as specified. 2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source. 3. Turn off master switch (if equipped). 4. Remove the upper and lower rear panels (side panel on H10X). 5. Install the proper electrical wiring to the terminal block. 6. On Dual Volt models, make sure the toggle switch below the circuit board is set to the desired voltage (120 volts or 208/240 volts) and the red switch on the circuit board is in the “SET” position. 7. Connect the dispenser to the power source and verify the voltage at the terminal block before proceeding. Reinstall both rear panels. 8. If plumbing is to be hooked-up later be sure the dispenser is disconnected from the power source. If Plumbing has been hooked-up, the dispenser is ready for Initial Set-Up. Note: This electrical service consists of 2 current carrying conductors (L1 and L2) and a separate conductor for earth ground. POWER CORD L2 RED L2 RED WHITE NEUTRAL WHITE N L2 NEUTRAL L1 BLACK L1 BLACK L1 GREEN G 120/208 & 120/240V ac single phase models Note: This electrical service consists of 3 current carrying conductors (Neutral, L1 and L2) and a separate conductor for earth ground. DUAL VOLT TOGGLE SWITCH CE REQUIREMENTS • This appliance must be installed in locations where it can be overseen by trained personnel. • For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C. • Appliance shall not be tilted more than 10° for safe operation. • An electrician must provide electrical service as specified in conformance with all local and national codes. • This appliance must not be cleaned by water jet. • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of this appliance by a person responsible for its safety. • Children should be supervised to ensure they do not play with the appliance. • If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard. 4 39338.1 072409 PLUMBING REQUIREMENTS This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 90 psi (138 and 620 kPa)from a ⁄2” or larger supply line. A shut-off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is ⁄4” flare. 1 1 NOTE - Bunn-O-Matic recommends ⁄4” tubing for installations of less than 25 feet and ⁄8” for more than 25 feet from the ⁄2” water supply line. At least 18 inches of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the countertop. BunnO-Matic does not recommend the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line by this type of device may restrict water flow. 1 3 1 This equipment must be installed to comply with the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A., you must comply with the applicable Plumbing/Sanitation Code for your area. Plumbing Hook-Up 1. Remove the shipping cap from the fitting on the rear of the dispenser, and attach the flare elbow fitting (supplied separately with the dispenser) to the fitting. 2. Flush the water line and securely attach it to the flare fitting. H5E/X/DV-PC H10X INITIAL SET-UP CAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Connect dispenser to the power source and turn on water supply. 2. Place master ON/OFF switch in the ON position (if equipped). 3. Water will automatically flow into the tank to the proper level and shut-off. When filled, the water heater will turn on automatically. 4. The tank will heat to the (set) temperature. 5. Refer to Programming to set the Tank Temperature and the Ready Temperature. 5 39338.1 091610 PROGRAMMING When power is applied to the dispenser, the display located on the bottom of the main circuit board will show the software version for 5 seconds, and then it will show the model number (see chart below) it will then go to (-). While the tank is filling, the display will read (FIL). When the tank is full the display will show the model number and then go to (-). MODEL DISPLAYS (H5H) (H5L) (HPC) (H10) 5 Gallon High Voltage Unit (200-240V) 5 Gallon Low Voltage Unit (100-120V) 5 Gallon Portion Control Unit (all) 10X (all) Switch must be in “SET” position for access into programming modes. LEFT BUTTON CENTER BUTTON RIGHT BUTTON LEVEL 1 PROGRAMMING 1. Before programming any settings into the Control Board, confirm the correct model number is entered. 2. Do this by pressing and holding down on the center button until P1 appears on the display. Release the center button. The display will now show the model number (ex: H5H). Now scroll with the (+/-) buttons through the models listed above until the display matches the model you are working with. 3. Press and release the center button once more. The display will show P2. Display will now show the tank temperature (ex: 200). Press the (+) button to increase the temperature set point, or the (-) button to decrease the set point. NOTE: If the unit is a H5X or H10X, set the Tank Temperature to 212°F. 4. After the Tank Temperature is entered, press and release the center button once more. The display will read P3, then show the ready temperature set point. Factory default is 195° F for most dispensers, and 85° F for some. 5. Press the (+) button to increase the set point, or the (-) button to decrease the set point. 6. To exit Level 1 Program press and release the center button once more. The display will show Software version, then model number, then (-). 6 39338.1 072409 PROGRAMMING (Continued) LEVEL 2 PROGRAMMING H1 - DISPENSE TEMPERATURE LOCKOUT - PORTION CONTROL ONLY (WILL NOT DISPLAY ON OTHER MODELS) 1. To enter Level 2 Programming, press and hold the center button until H1 appears on the display (approximately 6 seconds) then release button. The display will either read noL (LOCKOUT DISABLED) or Loc (LOCKOUT ENABLED). When (ENABLED), unit will not dispense if the Tank Temperature is below the (READY) temperature setting. 2. Use the (+) or (-) buttons to alternate between Loc and noL. 3. Press and release the center button once more to advance to H2. Or to exit Level 2, press and release the center button 3 times. Display will show, software version, then model number, then (-). H2 - F° OR C° SELECTION NOTE: Skip step 1 if going from H1 to H2. 1. To enter Level 2 Programming, press and hold the center button until H2 appears on the display (approximately 6 seconds). Release the center button, The display will show either FAH (Degrees in Fahrenheit) or CEn (Degrees in Centigrade). 2. Press and release the (+) or (-) buttons to alternate between FAH and CEn. 3. After setting FAH or CEn, to exit Level 2 Programming, press and release the center button twice. Display will show, software version, then model number, then (-). H3 - RESTORING FACTORY DEFAULTS 1. To restore Factory Defaults (This clears all settings that were previously entered), press and release the center button until H2 appears on the display (approximately 6 seconds). Release the Center Button, then press and release the Center Button once more. The display will read H3, then show (- - -). 2. Press and hold both (+) and (-) buttons to initiate the resetting of the factory default settings. The display (- - -) will flash on and off during this time (about 5 to 7 seconds). 3. When the factory default numbers are loaded in, the display will stop flashing, then read don (DONE). You can now release the two buttons. NOTE: If you release the two buttons at any time before the display reads don, the Factory Default numbers will not be entered. The old numbers will remain in the memory. 4. To exit Level 2 Programming press and release the center button once more. The display will show the Software version, then model number, then (-). 7 39338.1 072409 OPERATING CONTROLS - PORTION CONTROL ONLY d. (a) VOLUME SELECTOR BUTTONS Press and release the button corresponding to the Small, Medium, or Large volume, to select the desired amount of water to be dispensed. Pressing a different button after a cycle has been initiated does not change the volume in progress. (b) AUTO STOP/MANUAL DISPENSE BUTTON Press and release button to stop a dispense cycle. Press and hold button to dispense manually. (c) HIDDEN PROGRAMMING BUTTON (d) LED INDICATORS (e) DISPENSE NOZZLE c. a. b. e. ADJUSTING DISPENSE VOLUMES NOTE: The dispenser should be at operating temperature before setting dispense volumes. 1. Press and hold the hidden programming button (c) located under the ® next to the BUNN logo on the front of the dispenser until the 3 LED's begin flashing from the left to the right. Release the button. 2. Place an empty graduated container under the dispense nozzle (e). 3. Press and release the batch size to be set (a). The LED's will stop flashing, and the LED over the button just pressed will come on steady. Water will begin to dispense into the container. 4. When the desired amount of water is dispensed, press and release the same button (a). The water will stop dispensing and the batch size is now set. 5. The LED's will begin flashing from left to right again. Repeat steps 2 thru 4 to set up the other batch sizes. 6. To exit the programming set up at any time, press and release the hidden button once (c). The dispenser is now ready for use. 8 39338.1 072409 DRAINING THE DISPENSER CAUTION - The dispenser must be disconnected from the power source throughout these steps. 1. 2. 3. 4. 5. Disconnect the dispenser from the power source. Shut-off and disconnect the incoming water supply and allow dispenser to cool. Remove the 4-40 screws and the top cover. Gently remove one of the grommets from the tank lid. Insert a tube to the bottom of the tank and syphon ALL of the water out. NOTE - The dispenser must be full using the INITIAL SET-UP steps before reconnecting to the power source. CLEANING The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. H5E/H5E-PC/H5X ONLY: WALL MOUNTED INSTALLATION If the dispenser is wall mounted, the bottom of the dispenser should be at the same height as a counter or table top. Use B.O.M. part #12542.0000 for side mounted Wall Bracket Kit or # 13125.0001 for front mounted Wall Bracket Kit . SUPPORT FOR LARGE RECEPTACLES CAUTION: If the dispenser is to be used with larger receptacles such as pitchers or pots, those receptacles must be adequately supported during dispensing of hot water to avoid spillage of very hot water. This support may be provided by a table or counter top, or use B.O.M. part #12599.0000 Shelf Kit. 9 39338.1 072409
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : mark Create Date : 2010:09:16 16:42:59-05:00 Modify Date : 2014:03:06 11:17:50-06:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 9.3.3 (Macintosh) Creator Tool : Adobe InDesign CS4 (6.0.5) Metadata Date : 2014:03:06 11:17:50-06:00 Document ID : uuid:46d7a091-889f-ee45-affe-c420c655e71c Instance ID : uuid:f3ecc0ef-10ff-b04f-9eba-214b4aeac795 Format : application/pdf Creator : mark Title : 39338.0001B.indd Page Count : 9EXIF Metadata provided by EXIF.tools