SERIES 4S ` Power Flame Burner Information Burner Model Motor Standard UL Flame Safeguard Gas and Boiler Size Gas/#2 Oil #2 Oil 4S-100 C3-25B C3-OB 4S-125 C4-30 C4-OA 4S-150 C4-30 C4-OB 4S-175 C5-30 C5-O 4S-200 C6-30 C6-O 4S-250 C6-30 C6-O 4S-300 C7-30 C7-O 4S-350 C8-30 C8-O* 4S-400 CM9B-30 CM9B-O 4S-500 CM10-30 CM10-O 4S-600 CM10B-30 CM10B-O 4S-700 CM10C-30 CM10C-O 4S-800 CM11-30 CM11C-O [1] Explanation of Firing Sequences: HP 3 5 5 71/2 10 10 15 15 71/2 10 15 20 25 Voltage 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 208-460/60/3 Firing Sequence [1] L-H-O L-H-O L-H-O Full Mod Full Mod Full Mod Full Mod Full Mod Full Mod Full Mod Full Mod Full Mod Full Mod Gas RM7897C/UV RM7897C/UV RM7897C/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV #2 Oil RM7897C/UV RM7897C/UV RM7897C/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV RM7840L/UV [2] Gas/#2 Oil Size RM7897C/UV 2 RM7897C/UV 21/2 RM7897C/UV 21/2 RM7840L/UV 3 RM7840L/UV 3 RM7840L/UV 3 RM7840L/UV 3 RM7840L/UV 3 RM7840L/UV 3 RM7840L/UV 3 RM7840L/UV 3 RM7840L/UV 3 / 4 RM7840L/UV 3HF Gas Train Min. Pres. 7.3" w.c. 9.9" w.c. 13.2" w.c. 11.6" w.c. 12.8" w.c. 17.0" w.c. 26.8" w.c. 32.4" w.c. 40.9" w.c. 63.0" w.c. 91.0" w.c. 90.0" w.c. 94.0" w.c. Max. Pres. 14.0" w.c. 14.0" w.c. 14.0" w.c. 28.0" w.c. 28.0" w.c. 28.0" w.c. 10 psig 10 psig 10 psig 10 psig 10 psig 10 psig 10 psig *order burner with 6" insertion depth. Gas and Gas Sequence on Combination Gas/Oil Boilers L-H-O Low fire start (not proven), high fire run, air control by linkage to motorized gas valve. Full Mod Full modulation with proven low fire start, synchronized fuel/air control with modulating motor. Oil and Oil Sequence on Combination Gas/Oil Boilers L-H-O Low fire start (not proven), high fire run, oil cylinder air control (reduced input start) with by-passing type nozzle, oil valve and oil pressure regulating valve. Full Mod Full modulation with proven low fire start, synchronized fuel/air control with modulating motor, oil by-passing type nozzle, oil metering valve, oil pressure regulating valve. [2] Models 4S-700 - Dual size gas trains: Leak test cock, main gas valve and auxiliary gas valve are indicated by the first number; gas regulator and main shutoff cock are indicated by the second number. 11/3/06 SERIES 4S Power Flame Burner Equipment Equipment Control Cabinet Fuel Gas, #2 Oil, Gas/#2 Oil NEMA 1A with hinged door. Control Voltage Transformer Gas, #2 Oil, Gas/#2 Oil Included Motor Starter Gas, #2 Oil, Gas/#2 Oil Magnetic starter with overload protection with. Fusing Gas, #2 Oil, Gas/#2 Oil Control circuit only. Ignition Gas and Gas/#2 Oil #2 Oil Signal Lights Air Flow Safety Switch Gas/Electric pilot. Direct spark 100 through 150. Gas/Electric pilot 200 and larger. Gas, #2 Oil, Gas/#2 Oil LHO, Two [power on and fuel on]. Full Modulation, Four [power on, fuel valve open, call for heat, flame failure.] Gas #2 Oil Gas/#2 Oil Gas Train Gas and Gas/#2 Oil All models. On models 175 and larger. All models, functions with both fuels. UL gas train for minimum inlet pressure indicated on Burner Information table. Assembled, wired and mounted on unit consisting of the following: z z z z z z Oil Pump Pilot Gas Controls Fuel Changeover Description #2 Oil and Gas/#2 Oil Manual shut-off valve. Gas pressure regulator. Manual leak test valve. Automatic gas valve: Motorized. Proof of closure on model 125 and larger. Safety gas valve: Solenoid type. Motorized on model 200 and larger. High and Low gas pressure switches Two stage, integral with burner on model 100. Separate oil pump set with motor and accessories mounted on boiler skid model 125 and larger. Gas, #2 Oil, Gas/#2 Oil All models with gas/electric pilot have manual pilot shut-off valve, gas pressure regulator and solenoid gas valve. Gas/#2 Oil Manual switch. 6/23/2005
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : CNosal Create Date : 2013:07:09 13:40:57-04:00 Modify Date : 2013:07:09 13:41:19-04:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Title : 4S Series 7-8-13.xls Creator : CNosal Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2013:07:09 13:41:19-04:00 Producer : Acrobat Distiller 9.5.5 (Windows) Document ID : uuid:82d2f47e-a38f-4eab-bdd8-a8f0fa703c9f Instance ID : uuid:ca4b569e-a04f-4ab5-9ae8-6dc071d13713 Page Count : 2EXIF Metadata provided by EXIF.tools