Burnham Series 8B Brochure Layout 9 03
2015-06-08
: Burnham Burnham-Series-8B-Brochure-738051 burnham-series-8b-brochure-738051 burnham pdf
Open the PDF directly: View PDF .
Page Count: 4
1
EFFICIENT & ECONOMICAL
COMMERCIAL GAS-FIRED
HOT WATER HEATING
SERIES 8B HEATING CAPACITTIES
212 TO 475 MBH OUTPUT
2
quickly and efficiently while
providing unmatched durability.
The pinned
heating surface
and vertical
flue design
extracts
maximum heat
while
maintaining
low draft
losses. This results in higher
efficiencies and lower fuel costs.
The Cast Iron Nipple Difference
Burnham Commercial's Series 8B
boiler sections are joined with
quality cast
iron nipples
that last the life
of the boiler.
They expand
and contract
along with the
Adaptable to Any Job
The Burnham® Commercial
Series 8B boiler provides
outstanding single and multiple
boiler performance and reliability.
The boiler can be arranged for
space heating or combination space
heating and domestic hot water
heating with the use of an
Alliance™ indirect-fired water
heater. The compact design and one
inch minimum side clearance make
the Series 8B ideal for modular and
multiple boiler installations*. Large
homes, multi-family dwellings,
small businesses and office
complexes are typical applications
for the Series 8B boiler.
Cast Iron Dependability
The Series 8B boiler is
constructed with durable cast iron
sections. Cast iron has the unique
ability to absorb and transfer heat
SERIES 8B COMMERCIAL ATMOSPHERIC
GAS-FIRED HOT WATER BOILER
Maximum Working Pressure: 50 PSI
sections they join ensuring the
integrity of the entire section
assembly. Cast iron nipples resist
petroleum based chemicals,
including corrosion inhibitors,
pump lubricants, and antifreeze,
and they do not break down from
contact with boiler flue gases, all
of which can deteriorate the
gaskets commonly used in some
competitors’ boiler assemblies.
Features Beyond the Standard
A flame roll-out switch and
blocked vent switch are standard
equipment on all Series 8B boilers.
The flame roll-out switch senses
temperature in the vestibule and
the blocked vent switch senses
temperature at the flue outlet.
The switches will safely shut
down the boiler in the event the
boiler, chimney or venting system
becomes blocked or restricted.
Dimensions (in inches)
relioB rebmuN A B C
D E
ASU adanaC ASU adanaC
B508 B608 B708 B808 B908 B018
02 4/3-32 2/1-72 4/1-13 53 4/3-83
01 8/7-11 4/3-31 8/5-51 2/1-71 8/3-91
7
8
9
9
0101
4/3-42 4/3-72 4/3-82 4/3-03 2/1-33 2/1-33
4/3-42 4/3-52 4/3-52 8/5-62 8/3-62 8/3-62
8/1-61 8181022222
8/1-61 6161615151
*Minimum recommended side-to-
side clearance for modular/multiple
boiler applications is one inch or as
required by local authorities. New EP
and OP electronic control sets are
designed to mount on top of the
boiler and does not affect side
clearances. When equipped with IRI
(Industrial Risk Insurers) controls,
the gas train will mount along the
right side of the boiler, requiring 18”
service clearance.
*Please refer to the Modular/Multiple
Boiler and Controls literature and
Modular manual for detailed
installation information.
3
Modular or Multiple
ASME Section IV differentiates
between modular and multiple
boiler installation. According to
ASME, a modular boiler system
consists of individual modules with
a maximum input of 400 MBH
each. Each module is to be
equipped with a pressure
temperature gauge, temperature
limit control, safety relief valve and
drain valve. The modules are to be
manifolded together on site without
any intervening stop valve. The
modular boiler assembly is to be
equipped with a common
temperature limit control, low water
cutoff, makeup water connection,
provision for thermal expansion and
supply and return stop valves.
Multiple boiler installations
require a stop valve in the supply
and return pipe connection of each
boiler. Each boiler needs to be
equipped with a pressure
temperature gauge, two
temperature limit controls, safety
relief valve, and drain valve.
Boilers over 400 MBH must also
include an automatic low water
cutoff. Sizes 805, 6 and 7 can be
installed as modular or multiple
boilers. Sizes 808, 9 and 10 are to
be installed as multiple boilers. In
both cases, minimum recommended
side-to-side clearance is one inch or
as required by local codes.
Commitment to Quality
Burnham Commercial, America's
Boiler Company, has earned a
reputation for dependability and
quality. For single or multiple
applications, the Series 8B is right
for your next job.
A. Top mounted drafthood
B. Blocked vent switch (BVS)—All sizes
C. Rugged cast iron nipples join sections
D. Deluxe insulated jacket
E. Durable cast iron sections for long life
F. Aluminized steel burners—provide optimum air flow for high
combustion efficiency, smooth and quiet light-off and long life
G. Factory assembled gas manifold with plugged test tapping
saves installation time and money
H. Flame roll-out switch (FRS)—All sizes
I. 100% step-opening gas valve—redundant type on EI
J. Solenoid valve—standing pilot version only
K. 50 VA voltage transformer
L. Pressure temperature gauge
M. Safety relief valve
A
C
D
B
G
E
F
H
I
J
K
LM
4
SPECIFICATIONS
Form No.PL81401161000-10/03-5Mc
Printed in the U.S.A.
© 2003 Burnham Commercial, LLC — Lancaster, PA
Phone: 888-791-3790
www.burnhamcommercial.com
SERIES 8B RATINGS* Natural and LP Gas
Optional Equipment
30 PSI Safety Relief Valve Electronic Control Sets to meet CSD-1 and IRI
Electronic Ignition on 806B and 807B Vent Damper - 806B thru 810B (standard on 805B), available on
(standard on 805B, 808B-810B) standing pilot and electronic ignition models only - not available
Intermittent Circulation (24V) with Electronic Control Sets.
Combustible Floor Shield
NOTE: NOT FOR DIRECT INSTALLATION ON COMBUSTIBLE FLOORING. A HEAT SHIELD IS REQUIRED AND AVAILABLE FOR COMBUSTIBLE FLOOR
INSTALLATION AND CONCRETE INSTALLATION WHICH IS OVER A MATERIAL THAT IS SUBJECT TO MELTING (PVC, PEX RADIANT TUBING ETC.).
NOT FOR INSTALLATIONS ON CARPET, EVEN WITH A HEAT SHIELD.
Standard Equipment
Cast Iron Section Assembly Blocked Vent Switch (BVS) - All Sizes
Deluxe Insulated Jacket Flame Roll-Out Switch (FRS) - All Sizes
100% Shut-off Gas Controls L4080D High Limit Control
Boiler Drain Valve PS851M Probe LWCO - 808B-810B only
50VA Transformer and Junction Box High Limit Control with Manual Reset - L4006E (in addition to
Aluminized Steel Burners L4080) - Packaged Boilers Only
1” Gas Connection Electronic Ignition on 805B, 808B-810B for Natural or LP Gas
2” Supply And Return Connections 24V Standing Pilot on 806B, 807B for Natural or LP Gas
50 PSI Safety Relief Valve Pressure Temperature Gauge
Packaged units are shipped packaged and wired. The relief valve, pressure temperature gauge, boiler drain valve, drafthood and
LWCO and vent damper (when furnished) are shipped in separate cartons. Knockdown units are shipped with sections
assembled and mounted on the base with manifold and burners installed. Controls, trim, jacket and vent damper
(when furnished) are shipped separately.
*Ratings shown are for installations at sea level and elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should
be reduced at the rate of four percent (4%) for each 1,000 feet above sea level.
1. When ordering use prefix P for packaged and K for knockdown. Use suffix NSP for natural gas, standing pilot; NEI for natural
gas, electronic ignition; PSP for LP gas, standing pilot; PEI for LP gas, electronic ignition.
2. Net I=B=R ratings shown are based on normal I=B=R piping and pickup allowance of 1.15.
Consult the manufacturer for installations having unusual piping and pickup requirements such as intermittent system of
operation, extensive piping systems, etc.
3. 15 foot height is measured from top of drafthood to top of chimney.
4. DOE heating capacity. Furnished with electronic ignition and vent damper. AFUE is 80.1%.
Maximum allowable working pressure: 50 PSI (30 PSI optional). Water only.
RELIOB REBMUN )1(
SGNITAR
R=B=I GNITARTEN HBMRETAW
LARUTANMUMINIM )SEHCNI(ERUSSERPSAG
DEDNEMMOCERMUMINIM DNUOREZISYENMIHC ).tF(.THX).nI(.AID
RETAW TNETNOC ).laG(
.XORPPA GNIPPIHS THGIEW ).sbL(
TUPNI HBM
SSORG TUPTUO HBM V42 IE
B508 B608 B708 B808 B908 B018
462 033 693 264 825 495
)4(212 462 713 073 224 574
481 032 572 123 763 314
A/N 5.4 0.5 A/N A/N A/N
5.4 5.4 5.4 5.4 0.5 0.5
51X7 51X8 51X9 51X9 51X01 51X01
9.11 9.31 9.51 9.71 9.91 9.12
007 087 588 099 5901 6021