Burnham Series V11 Brochure
2015-06-08
: Burnham Burnham-Series-V11-Brochure-738054 burnham-series-v11-brochure-738054 burnham pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | ![]() |
Open PDF In Browser | View PDF |
V11 Series Cast Iron Commercial Water or Steam Boiler 837 to 5733 MBH Input Oil, Gas, or Oil/Gas Combination 30, 50, or 80 PSI Cast Iron Sectional Design Water or Steam Top or Rear Venting Exclusive Optional SBC Boiler Controlª Ð M aximizes System Efficiency 1 V11 Series Cast Iron Commercial Water or Steam Boiler Your Commercial Heating Solution! Available in twenty sizes with gross output ratings from 667 to 4551 MBH, the V11 Series is commonly used in schools, hospitals, and other large commercial applications where comfort and reliability are critical. The product meets the energy efficiency requirements of ASHRAE 90.1 with combustion efficiencies up to 85%. Installation & Service Flexibility Cast iron construction, ease of assembly, two venting options, and stringent testing methods make the V11 Series boiler by Burnham Commercial your commercial heating solution. • Hassle-free Section Assembly The cast iron sectional design of the V11 boiler makes it easy to maneuver through doorways and into the boiler room. In addition to being shipped as loose sections, the boiler is available with factory-assembled sections or as a completely packaged and fire-tested unit. V11 boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly. American-Made Cast Iron ConstructionÐ BC25-HSi Burnham CommercialÕ s unique BC25-HSi cast iron formula has an extremely high silicon content, making it stronger and more flexible than the iron used in competitor's boiler sections. It offers better thermal shock resistance and greater heat transfer capabilities than other cast iron products. BC25-HSi's properties allow Burnham Commercial to maintain the highest level of quality from start to finish, and provide a product that is optimized for hydronic heating applications. The sections can be assembled using two common toolsÑ a 3/4" drive ratchet with a 1-1/16" deep socket and wrench. The sections are surface ground to ensure smooth surface mating. An elastic sealant and fiberglass rope are used on all section joints for a completely sealed and pressure-tight assembly. • extensive Testing Methods Each boiler section is hydrostatically tested at 2-1/2 times the rated working pressure at the foundry. Factory- assembled sections are tested a second time at 1.5 times the rated working pressure. • Manufactured with Quality Cast iron sections are produced at Burnham Foundry LLC in Ohio, ensuring quality and availability of boiler sections. • Rear or Top Venting As a forced draft boiler, the V11 provides optimum draft for controlled efficiency, eliminating the need for high chimneys or induced draft fans. A unique feature of the V11 boiler is that it can be vented from the rear or the top. This enables easy chimney or sidewall venting for maximum installation flexibility. Top outlet venting saves floor space and reduces installation time and materials. A plugged tapping is provided to take flue outlet pressure readings. • Cast Iron nipple Difference V11 sections are held together using cast iron nipples, which are well known as being of the highest standard for boiler construction. Unlike gaskets used by many other boiler manufacturers, cast iron nipples are impervious to flue gases, oils, petroleum-based chemicals and other contaminants, which means fewer costly repairs and a longer lasting boiler. 2 Commitment to Quality Burnham Commercial, "America's Boiler Company," has earned a reputation for quality and dependability. Built for a variety of applications, the V11 Series is right for your next job. Top or Rear Outlet with adjustable lock-type damper (not shown); includes plugged tapping for outlet pressure readings Front Mounted Controls for easy adjustment and maintenance Aluminized Steel Canopy Burner Mounting plate with flame observation port Cast Iron nipples ensure the integrity of the section assembly and resist petroleum based chemicals and flue gases Removable Side Jacket panels Easy access to all cleanouts and flue surfaces Cast Iron Sections Vertical flue design with pinned heating surface for maximum heat extraction 4 Burner Manufacturers Rear Observation port Options to best fit your needs Includes plugged tapping for over-fire draft readings Individual Draw Rods Wet Base with reinforced lugs for strain free assembly Side wall insulation creates improved thermal circulation Optional Tankless Heater Provides domestic hot water Also AvailableÉ SBC TM Integrated Boiler Control System Burnham CommercialÕ s SBC is a complete boiler monitoring and automation system. Available as an option, this exclusive feature was designed and developed by Burnham Commercial’s engineers and is available ONLY on Burnham Commercial products. SBC Exclusives Designed to maximize system efficiency and minimize energy usage Easily connected to building management systems Proven control platform, used successfully for years at other Burnham companies Fail-safe design insures boiler operation • Advanced Adaptability • Peer-To-Peer Network • Fail-Safe System Operations • Boiler Monitoring & Diagnostic Displays • Modulation Rate and On/Off Modes • Outdoor Air Temperature Reset • Warm Weather Shutdown (WWSD) • Domestic Hot Water Priority (DHWP) • System Control Outputs 3 The SBC Boiler Control SystemÉ Only available from Burnham Commercial! V11 Series Dimensions BURneR DIMenSIOn - 'M' * BOILeR MODeL V1104 V1105 V1106 V1107 V1108 V1109 V1110 V1111 V1112 V1113 V1114 V1115 V1116 V1117 V1118 V1119 V1120 V1121 V1122 V1123 nUMBeR OF SeCTIOnS 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 BeCKeTT 'A' 26-5/8 32-3/4 38-7/8 45 51-1/8 57-1/4 63-3/8 69-1/2 75-5/8 81-3/4 87-7/8 94 100-1/8 106-1/4 112-3/8 118-1/2 124-5/8 130-3/4 136-7/8 143 'B' 18-7/8 25 31-1/8 37-1/4 43-3/8 49-1/2 55-5/8 61-3/4 67-7/8 74 80-1/8 86-1/4 92-3/8 98-1/2 104-5/8 110-3/4 116-7/8 123 129-1/8 135-1/4 'C' Ñ Ñ 31-1/8 37-1/4 43-3/8 49-1/2 24-3/4 37 37 37 24-3/4 24-3/4 30-7/8 30-7/8 30-7/8 30-7/8 30-7/8 30-7/8 30-7/8 30-7/8 'D' Ñ Ñ Ñ Ñ Ñ Ñ 30-7/8 24-3/4 30-7/8 37 24-1/2 24-1/2 36-3/4 36-3/4 24-1/2 24-1/2 24-1/2 24-1/2 24-1/2 24-1/2 'e' Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ 30-7/8 37 24-3/4 30-7/8 24-1/2 24-1/2 36-3/4 36-3/4 24-1/2 24-1/2 'F' Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ 24-3/4 30-7/8 24-3/4 30-7/8 24-1/2 24-1/2 'G' 'H' Ñ 13-13/16 Ñ 19-15/16 Ñ 26-1/16 Ñ 32-3/16 Ñ 38-5/16 Ñ 44-7/16 Ñ 50-9/16 Ñ 56-11/16 Ñ 56-5/8 Ñ 53-5/16 Ñ 53-5/16 Ñ 53-5/16 Ñ 53-5/16 Ñ 53-5/16 Ñ 53-5/16 Ñ 53-5/16 Ñ 53-5/16 Ñ 53-5/16 24-3/4 53-5/16 30-7/8 53-5/16 'J' 55 55 55 54 54 54 53 53 53 53 52 52 52 52 51 51 51 51 50 50 all dimensions in inches * Burner control panel configuration may change this dimension FRONT OBSERVATION PORT 4 'K' 8 8 8 10 10 10 12 12 12 12 14 14 14 14 16 16 16 16 18 18 'L' 1 2 2 3 3 4 4 4 5 5 5 6 6 6 7 7 8 8 9 9 CF 24-3/4 24-3/4 24-3/4 24-1/4 24-1/4 24-1/4 24-1/4 24-1/4 25-3/4 25-3/4 27 27 26 Ñ Ñ Ñ Ñ Ñ Ñ Ñ CG 21-3/4 21-3/4 28-3/4 29-1/4 29-1/4 29-1/4 29-1/4 29-5/8 29-5/8 29-5/8 29-5/8 29-5/8 29-5/8 29-5/8 29-5/8 29-5/8 Ñ Ñ Ñ Ñ pOWeRFLAMe WeBSTeR CARLIn Ñ 19-3/4 19-3/4 20-1/2 20-1/2 20-1/2 25-5/8 25-5/8 25-5/8 26-1/8 26-1/8 26-1/8 26-1/8 26-1/8 Ñ Ñ Ñ Ñ Ñ Ñ CR 30 30 35 35 35 35 35 40 40 40 40 40 40 40 40 40 40 40 46 46 JR** 20-1/4 20-1/4 23-3/4 23-3/4 23-3/4 Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ JB 25 25 25 25 25 25 25 29 29 29 29 29 29 29 29 29 29 29 29 29 AppROX. WeIGHT OF SeCTIOn (Assembly Only) 1833 2226 2618 3010 3403 3795 4188 4580 4972 5365 5757 6150 6542 6934 7327 7719 8112 8504 8896 9289 V11 Series Piping Recommendations Water Boiler pipe Sizing and notes nOTeS: 1. All piping is schedule 40. 2. Pipe size listed are based on a 20° F or 40° F differential (temperature drop). Select one to match application. 3. When specified return piping size is less than 3", install 3" x 12" nipple and appropriate size bell reducer directly into boiler return tapping as shown. 4. Drain valve - ball valve preferable, gate valve acceptable alternative (supplied by others). Minimum valve size per ASME code is 3/4" NPT. 5. Swing joints on two riser systems may be piped over the top of the boiler if space is limited. 6. Boilers require protection from flue gas condensation and thermal shock when operating below 135°F return water temperatures BOILeR MODeL V1104 V1105 V1106 V1107 V1108 V1109 V1110 V1111 V1112 V1113 V1114 V1115 V1116 V1117 V1118 V1119 V1120 V1121 V1122 V1123 SUppLy pIpInG SIZe In InCHeS (1B) (1A) SUppLy RISeR SUppLy (1) (QTy.) SIZe HeADeR SUppLy 20¡ F 40¡ F 20¡ F 40¡ F 20¡ F 40¡ F DROp DROp DROp DROp DROp DROp Ñ Ñ Ñ Ñ 2 2-1/2 Ñ Ñ Ñ Ñ 2 2-1/2 Ñ Ñ Ñ Ñ 2 2-1/2 Ñ Ñ Ñ Ñ 2 3 Ñ Ñ Ñ Ñ 2 3 Ñ Ñ Ñ Ñ 2-1/2 4 Ñ Ñ Ñ Ñ 2-1/2 4 Ñ Ñ Ñ Ñ 2-1/2 4 Ñ Ñ Ñ Ñ 3 4 Ñ Ñ Ñ Ñ 3 4 Ñ Ñ Ñ Ñ 3 4 Ñ Ñ Ñ Ñ 3 4 Ñ (2) 3 Ñ 3 3 5 Ñ (2) 3 Ñ 3 3 5 Ñ (2) 4 Ñ 4 4 5 Ñ (2) 4 Ñ 4 4 5 Ñ (2) 4 Ñ 4 4 5 Ñ (2) 4 Ñ 4 4 5 Ñ (2) 4 Ñ 4 4 5 Ñ (2) 4 Ñ 4 4 5 5 ReTURn pIpInG SIZe In InCHeS (2B) (2A) ReTURn BRAnCH ReTURn (2) (QTy.) SIZe HeADeR ReTURn 20¡ F 40¡ F 20¡ F 40¡ F 20¡ F 40¡ F DROp DROp DROp DROp DROp DROp Ñ Ñ Ñ Ñ 2 2-1/2 Ñ Ñ Ñ Ñ 2 2-1/2 Ñ Ñ Ñ Ñ 2 2-1/2 Ñ Ñ Ñ Ñ 2 3 Ñ Ñ Ñ Ñ 2 3 Ñ (2) 3 Ñ 3 2-1/2 4 Ñ (2) 3 Ñ 3 2-1/2 4 Ñ (2) 3 Ñ 3 2-1/2 4 Ñ (2) 3 Ñ 3 3 4 Ñ (2) 3 Ñ 3 3 4 Ñ (2) 3 Ñ 3 3 4 Ñ (2) 3 Ñ 3 3 4 Ñ (2) 3 Ñ 3 3 5 Ñ (2) 3 Ñ 3 3 5 (2) 3 (3) 3 3 4 4 5 (2) 3 (3) 3 3 4 4 5 (2) 3 (3) 3 3 4 4 5 (2) 3 (3) 3 3 5 4 5 (2) 3 (3) 3 3 5 4 5 (2) 3 (3) 3 3 5 4 5 V11 Series Piping Recommendations Steam Boiler pIpInG SIZe In InCHeS (1) RISeR (2) (3) (4) BOILeR MODeL (QTy.) SIZe ReTURn HeADeR eQUALIZeR 2-1/2 4 2 (1) 4 V1104 2-1/2 4 2 (1) 4 V1105 2-1/2 6 2-1/2 (2) 4 V1106 2-1/2 6 2-1/2 (2) 4 V1107 2-1/2 6 2-1/2 (2) 4 V1108 2-1/2 6 2-1/2 (2) 4 V1109 2-1/2 6 2-1/2 (3) 4 V1110 4 8 3 (3) 4 V1111 4 8 3 (3) 4 V1112 4 8 3 (3) 4 V1113 4 8 3 (4) 4 V1114 4 8 3 (4) 4 V1115 4 8 3 (4) 4 V1116 4 8 3 (4) 4 V1117 4 8 3 (5) 4 V1118 4 10 3 (5) 4 V1119 4 10 3 (5) 4 V1120 4 10 3 (5) 4 V1121 4 10 3 (6) 4 V1122 4 10 3 (6) 4 V1123 RISeR SpACInG In InCHeS ÔAÕ Ñ Ñ 31-1/8 37-1/4 43-3/8 49-1/2 24-3/4 37 37 37 24-3/4 24-3/4 30-7/8 30-7/8 30-7/8 30-7/8 30-7/8 30-7/8 30-7/8 30-7/8 ÔBÕ Ñ Ñ Ñ Ñ Ñ Ñ 30-7/8 24-3/4 30-7/8 37 24-1/2 24-1/2 36-3/4 36-3/4 24-1/2 24-1/2 24-1/2 24-1/2 24-1/2 24-1/2 ÔCÕ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ 30-7/8 37 24-3/4 30-7/8 24-1/2 24-1/2 36-3/4 36-3/4 24-1/2 24-1/2 ÔD Õ Ô eÕ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ 24-3/4 Ñ 30-7/8 Ñ 24-3/4 Ñ 30-7/8 24-1/2 24-3/4 24-1/2 30-7/8 nOTeS: 1. All piping is schedule 40. 2. To prevent condensate from being trapped in header, do not reduce equalizer elbow at header connection. 3. Drain/blowoff valve — ball valve preferable, gate valve acceptable alternative (supplied by others). - Minimum valve size per ASME code is 1" NPT (V1104-1106), 1-1/4" NPT (V1107-1112), 1-1/2" NPT (V1113-1123). - Increasing the valve size will improve the blowdown operation - In all cases, piping connecting blowoff valve to boiler shall be full size to the point of discharge. 4. Header piping may be run over the top of boiler if space does not allow for piping arrangement shown. However, increased service requirements will result. 5. Supply from boiler header must be connected between the first boiler riser and the header drip (or hartford loop). Do not connect supply between risers or opposite end of boiler header. 6. For pumped return systems, see V11 installation manual. 'A' 'B' 'A' V1106 THRU V1109 V1104 AND V1105 V1 110 THRU V1113 'A' 18" MIN. 'A' 'A' 'B' 'B' 'C' 'C' 'B' 'C' 'D' 'D' 24" MIN. 'E' 1 RISER 3 HEADER 4 EQUALIZER CLOSE NIPPLE V1114 THRU V1117 V1118 THRU V1121 6 WATER LINE 2" TO 4" REAR OF BOILER HARTFORD LOOP (REQ'D ON GRAVITY RETURN SYSTEM) SUPPLY (SEE NOTE 5) 2 RETURN V1122 AND V1123 5 BLOWOFF/DRAIN VALVE (SEE NOTE 3) V11 Series Burner Schedule OIL BURneRS BeCKeTT CARLIn pOWeR FLAMe WeBSTeR BOILeR nUMBeR BURneR MODeL H.p. BURneR MODeL H.p. BURneR MODeL H.p. BURneR MODeL H.p. V1104 CF1400 1/2 Ñ Ñ CR1-OS 1/2 JB1O-03 1/3 V1105 CF1400 1/2 702CRD 1/2 CR1-OS 1/2 JB1O-03 1/3 V1106 CF1400 1/2 702CRD 1/2 CR2-OAS 3/4 JB1O-03 1/3 V1107 CF2300 3/4 801CRD 3/4 CR2-OAS 3/4 JB1O-05 1/2 V1108 CF2300 3/4 801CRD 3/4 CR2-OAS 3/4 JB1O-05 1/2 V1109 CF2300 3/4 801CRD 3/4 CR2-OAS 3/4 JB1O-07 3/4 V1110 CF2300 3/4 1050FFD 1 CR2-OAS 1-1/2 JB1O-07 3/4 V1111 CF2300 3/4 1050FFD 1 CR3-O 2 JB2O-10 1 V1112 CF2500 2 1050FFD 1-1/2 CR3-O 2 JB2O-10 1 V1113 CF2500 2 1050FFD 1-1/2 CR3-O 2 JB2O-10 1 V1114 CF3500 2 1150FFD 1-1/2 CR3-O 2 JB2O-10 1 V1115 CF3500 2 1150FFD 1-1/2 CR3-O 2 JB2O-10 1 V1116 CF3500 2 1150FFD 1-1/2 CR3-O 3 JB2O-15 1-1/2 V1117 Ñ Ñ 1150FFD 1-1/2 CR3-O 3 JB2O-30 3 V1118 Ñ Ñ Ñ Ñ CR3-OB 3 JB2O-30 3 V1119 Ñ Ñ Ñ Ñ CR3-OB 3 JB2O-30 3 V1120 Ñ Ñ Ñ Ñ CR3-OB 3 JB2O-30 3 V1121 Ñ Ñ Ñ Ñ CR3-OB 3 JB2O-50 5 V1122 Ñ Ñ Ñ Ñ CR4-OA 5 JB2O-50 5 V1123 Ñ Ñ Ñ Ñ CR4-OA 5 JB2O-50 5 STANDARD BURNER MOTOR VOLTAGE: Beckett – CF1400, and CF2300 are 120/60/1. CF2500 and CF3500 are 240/60/3. Carlin – All sizes 240/60/1. power Flame – CR1-OS is 120/60/1. CR2-OAS is 240/60/1. All others are 240/60/3. Webster – JB10-03, JB10-05 and JB10-07 are 120/60/1. JB20-10 is 240/60/1. All others are 240/60/3. GAS BURneRS* BeCKeTT pOWeR FLAMe - 'CR'= pOWeR FLAMe - 'JR'= WeBSTeR BOILeR BURneR MIn. GAS BURneR BURneR BURneR MIn. GAS nUMBeR MODeL H.p. pReSS. (In.) MODeL H.p. MODeL H.p. MODeL H.p. pReSS. (In.) V1104 CG10.6S 1/3 4.6 CR1-G-12 1/3 JR30A-10 1/3 JB1G-03 1/3 6 V1105 CG10.6S 1/3 6.6 CR1-G-12 1/2 JR30A-12 1/3 JB1G-03 1/3 4 V1106 CG15.4S 1/2 6.2 CR2-G-15 1/2 JR50A-15 1/3 JB1G-03 1/3 6 V1107 CG25.2S 3/4 5.2 CR2-G-15 1/2 JR50A-15 1/2 JB1G-05 1/2 5 V1108 CG25.3S 3/4 5.0 CR2-G-15 1/2 JR50A-15 1/2 JB1G-05 1/2 5 V1109 CG25.4S 3/4 5.2 CR2-G-15 1/2 Ñ Ñ JB1G-07 3/4 8 V1110 CG25.5S 3/4 5.2 CR2-G-20A 1 Ñ Ñ JB1G-07 3/4 8 V1111 CG50.2S 2 5.7 CR3-G-20 1-1/2 Ñ Ñ JB2G-10 1 8 V1112 CG50.3S 2 4.3 CR3-G-20 1-1/2 Ñ Ñ JB2G-10 1 6 V1113 CG50.3S 2 5.7 CR3-G-20 1-1/2 Ñ Ñ JB2G-10 1 7 V1114 CG50.4S 2 5.7 CR3-G-20 1-1/2 Ñ Ñ JB2G-15 1-1/2 8 V1115 CG50.5S 2 5.0 CR3-G-20 1-1/2 Ñ Ñ JB2G-30 3 8 V1116 CG50.5S 2 5.3 CR3-G-25 3 Ñ Ñ JB2G-30 3 8 V1117 CG50.5S 2 6.1 CR3-G-25 3 Ñ Ñ JB2G-30 3 9 V1118 CG50.5S 2 6.9 CR3-G-25B 3 Ñ Ñ JB2G-30 3 10 V1119 CG50.5S 2 7.3 CR3-G-25B 3 Ñ Ñ JB2G-30 3 11 V1120 Ñ Ñ Ñ CR3-G-25B 3 Ñ Ñ JB2G-30 3 12 V1121 Ñ Ñ Ñ CR3-G-25B 3 Ñ Ñ JB2G-50 5 14 V1122 Ñ Ñ Ñ CR4-G-25 3 Ñ Ñ JB2G-50 5 15 V1123 Ñ Ñ Ñ CR4-G-25 3 Ñ Ñ JB2G-50 5 16 STANDARD BURNER MOTOR VOLTAGE: power Flame C Series–CR1-G-12 and CR2-G-15 are 120/60/1. CR2-G-20A is 240/60/1. All others are 240/60/3. power Flame JR Series – All burners are 120/60/1. Webster–JB1G-03, JB1G-05 and JB1G-07 are 120/60/1. JB2G-10 is 240/60/1. All others are 240/60/3. * For inlet gas connection size, see Gas/Oil Burner Chart = For minimum gas pressure requirements, see Gas/Oil Burner Chart. GAS/OIL BURneRS pOWeR FLAMe - 'CR' SeRIeS WeBSTeR BOILeR BURneR InLeT GAS MIn. GAS BURneR InLeT GAS MIn. GAS nUMBeR MODeL H.p. COnneCTIOn (In.) pReSS. (In.) MODeL H.p. COnneCTIOn (In.) pReSS. (In.) V1104 CR1-GO-12 1/2 1 4.7 JB1C-03 1/3 1 7.0 V1105 CR1-GO-12 1/2 1 4.8 JB1C-03 1/3 1-1/4 4.9 V1106 CR2-GO-15 3/4 1 5.4 JB1C-03 1/3 1-1/4 7.0 V1107 CR2-GO-15 3/4 1 6.4 JB1C-05 1/2 1-1/4 6.2 V1108 CR2-GO-15 3/4 1 7.5 JB1C-05 1/2 1-1/2 6.9 V1109 CR2-GO-15 3/4 1-1/4 6.4 JB1C-07 3/4 1-1/2 7.0 V1110 CR2-GO-20A 1-1/2 1-1/4 5.8 JB1C-07 3/4 1-1/2 7.0 V1111 CR3-GO-20 2 2 5.8 JB2C-10 1 2 6.3 V1112 CR3-GO-20 2 1-1/2 6.0 JB2C-10 1 2 5.6 V1113 CR3-GO-20 2 1-1/2 6.8 JB2C-10 1 2 6.3 V1114 CR3-GO-20 2 1-1/2 7.4 JB2C-10 1 2 7.0 V1115 CR3-GO-20 2 1-1/2 7.3 JB2C-10 1 2 6.8 V1116 CR3-GO-25 3 2 6.6 JB2C-15 1-1/2 2 7.0 V1117 CR3-GO-25 3 2 7.1 JB2C-30 3 2 7.3 V1118 CR3-GO-25B 3 2 7.7 JB2C-30 3 2-1/2 8.1 V1119 CR3-GO-25B 3 2-1/2 6.5 JB2C-30 3 2-1/2 9.2 V1120 CR3-GO-25B 3 2-1/2 7.0 JB2C-30 3 2-1/2 10.0 V1121 CR3-GO-25B 3 2-1/2 7.0 JB2C-50 5 2-1/2 11.0 V1122 CR4-GO-25 5 2-1/2 6.3 JB2C-50 5 2-1/2 12.4 V1123 CR4-GO-25 5 2-1/2 6.9 JB2C-50 5 2-1/2 13.1 STANDARD BURNER MOTOR VOLTAGE: power Flame - CR1-GO-12 is 120/60/1. CR-2-GO-15 and CR2-GO-20A are 240/60/1. All others are 240/60/3. Webster–JB1C-03, JB1C05, JB1C-07 are 120/60/1. JB2C-10 is 240/60/1. All others are 240/60/3. **For minimum gas pressure requirements, see Gas Burner Chart. NOTES: 1. The minimum gas pressures shown are for standard UL burners with the standard firing sequence. IRI, FM and CSD-1 requirements may result in different pressures and prices. 7 Specifications V11 RATInGS BOILeR MODeL (1) V1104 V1105 V1106 V1107 V1108 V1109 V1110 V1111 V1112 V1113 V1114 V1115 V1116 V1117 V1118 V1119 V1120 V1121 V1122 V1123 GROSS OUTpUT MBH BOILeR (2) H.p. 667 19.9 857 25.6 1069 31.9 1281 38.3 1517 45.3 1729 51.7 1941 58.0 2154 64.3 2334 69.7 2503 74.8 2730 81.6 2957 88.3 3129 93.4 3353 100.2 3580 106.9 3739 111.7 3957 118.2 4174 124.7 4334 129.5 4551 136.0 I=B=R neT RATInG (3) STeAM MBH 500 643 802 963 1159 1335 1507 1672 1812 1943 2120 2296 2427 2603 2780 2903 3072 3241 3365 3533 SQ. FT. 2083 2679 3342 4013 4829 5563 6279 6967 7550 8096 8833 9567 10113 10846 11583 12096 12800 13504 14021 14721 WATeR MBH 580 745 930 1114 1319 1503 1688 1873 2030 2177 2374 2571 2718 2916 3113 3251 3441 3630 3769 3957 BURneR InpUT OIL GpH (4) 5.8 7.4 9.2 11.0 13.0 14.8 16.6 18.4 20.0 21.5 23.5 25.5 27.0 29.0 31.0 32.5 34.5 36.5 38.0 40.0 GAS MBH 837 1068 1328 1588 1876 2136 2396 2656 2887 3103 3392 3680 3897 4186 4474 4691 4979 5268 5485 5733 neT FIReBOX VOLUMe (In. WTR. COLUMn) 7.9 10.6 13.2 15.9 18.5 21.1 23.8 26.5 29.1 31.8 34.4 37.1 39.7 42.4 45.0 47.7 50.3 53.0 55.6 58.3 pReSSURe In FIReBOX (In. WTR. COLUMn) .35 .36 .37 .42 .42 .39 .42 .40 .42 .40 .38 .36 .38 .41 .39 .38 .38 .40 .41 .43 I=B=R VenT DIA. (In.) 8 8 8 10 10 10 12 12 12 12 14 14 14 14 16 16 16 16 18 18 AppROX. SHIppInG AnD LIFTInG WeIGHT (LBS.) 2105 2510 2920 3325 3733 4147 4557 4964 5374 5771 6184 6601 7008 7417 7823 8231 8638 9053 9456 9865 1. Suffix “S” indicates steam boiler, “W” indicates water boiler. Suffix “G” indicates gas-fired, “O” indicates oil fired and “GO” indicates combination gas/oil fired. 2. Boiler ratings are based on 13% CO2 on oil; 10.0% CO2 on gas, and + .10 in. water column pressure at boiler flue outlet. 3. I=B=R net ratings shown are based on piping and pick up allowances which vary from 1.333 to 1.288 for steam and 1.15 for water. Consult manufacturer for installations having unusual piping and pick up requirements, such as intermittent system operation, extensive piping systems, etc. 4. The I=B=R burner capacity in GPH is based on oil having a heat value of 140,000 BTU per gallon. Ratings shown above apply to altitudes up to 1000 feet for oil and 2000 feet for gas. For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each 1000 feet above sea level. nOTe: Maximum allowable working pressure (MAWP): Steam: 15 PSI Water – USA: 80 PSI (Standard relief valve provided is 50 PSI) (80 PSI/30 PSI Optional) Water – Canada: 50 PSI (Standard relief valve provided is 50 PSI) (30 PSI Optional) STAnDARD eQUIpMenT ALL BOILeRS: Sections unassembled, flush insulated jacket, burner mounting plate, rear observation port cover, fire wall plates, target wall (V1104-1106 only), rear flue outlet damper (top outlet optional), flue canopy, trim, and miscellaneous plugs, bushing and fittings STeAM TRIM: 15 PSI safety valve, L404F pressuretrol, gauge glass assembly, steam gauge WATeR TRIM: 50 PSI safety relief valve, L4006A high limit, pressure temperature gauge OIL BOILeRS: Flange mounted flame retention oil burner furnished with 2 stage fuel unit, primary control and dual oil valves GAS BOILeRS: Flange mounted gas burner with standard controls meeting the latest UL requirements, dual gas valves, gas-electric ignition with proven gas pilot, flame rod on JR burner, ultra violet flame detector on others, electronic programming controls and components are factory wired in a burner mounted control panel (except JR - panel available as an option) GAS/OIL BURneRS: Flange mounted combination gas/oil burner with standard controls meeting latest UL requirements, manually operated fuel transfer switch for dual fuel changeover, dual gas valves and oil valves, electric ignition with proven gas pilot on both fuels (direct spark ignition of oil is optional), ultra-violet flame detector, electronic programming controls and components are factory wired in a burner mounted control panel OpTIOnAL eQUIpMenT Assembled sections; completely packaged (includes manual reset high limit and manual reset low water cutoff); packaged and fire-tested; top outlet flue damper; tankless heaters; side inspection tappings with brass plugs; pressure relief door; 30 PSI and 80 PSI safety relief valves; combustion and hydronic controls to meet special applications including F.M., I.R.I., and ASME CSD-1. Burnham Commercial - Lancaster, PA Phone: -888-791-3790 www.burnhamcommercial.com 8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Modify Date : 2011:07:08 11:55:45-04:00 Create Date : 2011:06:29 16:50:36-04:00 Metadata Date : 2011:07:08 11:55:45-04:00 Creator Tool : Adobe InDesign CS4 (6.0) Format : application/pdf Document ID : uuid:0e70e3e0-4158-419b-b25c-b415e632f2fd Instance ID : uuid:18f2c5da-1ec1-4155-bd04-8f545221032b Producer : Adobe PDF Library 9.0 Page Count : 8 Creator : Adobe InDesign CS4 (6.0)EXIF Metadata provided by EXIF.tools