Busch Jaeger Elektro SAP-S-3-US System Access Point Wireless (Data Transmission System) User Manual

Busch-Jaeger Elektro GmbH System Access Point Wireless (Data Transmission System)

User Manual

Download: Busch Jaeger Elektro SAP-S-3-US System Access Point Wireless (Data Transmission System) User Manual
Mirror Download [FCC.gov]Busch Jaeger Elektro SAP-S-3-US System Access Point Wireless (Data Transmission System) User Manual
Document ID3890143
Application IDgCLp81rqVWQvu9oPVBksCA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.24kB (190534 bits)
Date Submitted2018-06-15 00:00:00
Date Available2018-06-15 00:00:00
Creation Date2018-06-12 07:36:00
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2018-06-12 07:36:00
Document TitleMicrosoft Word - SAP-S-3-US_Flyer-ABB_Korrekturexemplar_2018-06-12.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: Michael.Bruchhaus

Wired
free@home
Bus
Wired Bus
2CKA000073B9572 / 12.06.2018
Alternative
Power input
SAP-S-3-US
Wired Bus
Alternative
Power input
24 V DC
RJ45
24 V DC
RJ45
EN
FR
ES
...
2a
2b
LIS TE D E 498995
IC
System Access Point 2.0, ABB-free@home Installation and Operation Instructions
IMPORTANT: Carefully read all instructions and safety
information about this device before operation. Please leave this
document with the homeowner for future reference.
WARNING: Installation must be performed by a licensed
electrician or electrical professional. Improper installation can
cause property damage, personal injury, or loss of life.
WARNING: SHOCK HAZARD
Disconnect the main power supply prior to installation. Failure to
turn off the power can cause electrical shock or equipment
damage.
MOUNTING
■
Intended Use
The System Access Point 2.0 (SysAP) is the central controller hub of the
free@home network. It is used to identify and configure free@home
devices during installation. Once the devices are added to the network,
the SysAP is able to automatically execute user-defined programs and
facilitates manual interaction via the free@home app available on
smartphones, tablets, and PCs. Only one SysAP may be active on a
network at any time.
■
■
Additional Information
For more information on system integration or the range of functions,
please scan the QR code or refer to the system manual at
http://new.abb.com/products/2CKA006200A0156/
Box Contents
System Access
Point 2.0
Mounting Base
2 Wall Screws
2 Wall Anchors
1 free@home Wired Bus Connection
Terminal (Red/Black)
1 Power Supply Connection Terminal
(Yellow/White)
1 Plug Power Supply with Adapter
1 Strain-Relief Bracket with 2 Screws
English
Optional Accessories:
External Antenna
Operating Voltage
free@home Wired Bus
Voltage
free@home Wired Bus
Connection
Ethernet
Protection Rating
Operating Temperature
Storage Temperature
USB-Port
Transmission protocol
Transmission frequency
Maximum transmission
power WL (wireless)
WLAN standard
WLAN frequency range
Maximum transmission
power, WLAN
Ways to Mount the SysAP:
Option A - Wall: Screw the mounting base directly onto the
wall. Set the SysAP on the top and push it downwards.
Option B - Flat Surface: Place the SysAP on a flat surface (i.e.
on a table).
CONNECTION
■
■
SAP-S-3-US Technical Data
SAP-S-3-US
External Wall Plug Power Supply
(enclosed, SELV)
24 VDC / 300 mA
NEC Class 2 (LPS)
* Alternative
DIN Rail Power Supply
24 VDC / 300 mA (SELV)
NEC Class 2 (LPS)
■
Connection terminal: 0.8 - 1.0 mm
(AWG 18 - AWG 20)
■
Line type: J-Y(St)Y, 2 x 2 x 0.8 mm
■
Wire stripping: 6 - 7 mm
24 VDC via separate power supply
(sold separately)
■
Bus connection terminal:
0.8 - 1.0 mm (AWG 18 - AWG 20)
■
Line type: J-Y(St)Y, 2 x 2 x 0.8 mm
■
Wire stripping: 6 - 7 mm
RJ45
IP20
23° F to 113° F (-5° C to 45° C)
-40° F to 158° F (-40° C to 70° C)
2.0 (High Speed)
Total USB current: 500 mA
Wireless (WL)
free@home wireless
2.400 - 2.483 GHz
< 20 dBm
WLAN
IEEE 802.11 a/b/g/n/ac
2.400 - 2.483 GHz
5.100 - 5.725 GHz
< 20 dBm
The transmitter and receiver communicate via RF signals. The
transmission range depends on the structural conditions. Walls,
ceilings, and electrical equipment can affect wireless communication,
especially steel reinforcements or other large metal objects. Electrical
devices that send high-frequency signals (such as computers,
wireless routers, audio systems, and video systems) should be at
least 3-feet from this device.
If the System Access Point 2.0 is installed within a closed metallic
housing (i.e. breaker box), the external antenna should be connected
for WL operation and fed outside the box.
Stationary surface-mounting in interior, dry rooms only. Observe all
state and local regulations for installation.
■
■
Cat5 or Cat6 wires are connected directly via the Ethernet
port.
IMPORTANT: Use only shielded Cat5 or 6 wires.
For installations with a plug-in connection, the socket outlet
must be mounted close to the SysAP and be easy to access.
Use the enclosed power supply with the correct adapter to power the
SysAP. To connect the adapter to the power supply, simply slide it
down the rails on the power supply until it locks in place (See diagram
C & D). All other devices on the network (free@home wired bus) must
be powered by a separate NEC Class 2 (LPS) power supply.
Alternative: 24 V power cord, supplied by the DIN Rail Power Supply
(See mounting diagram) instead of enclosed power supply.
WARNING: Do not attempt to power the device using both the
DC power jack and the alternative DC power connection. Use
only a single connection.
Connection Diagram
2a
2b
■
■
■
Green - Briefly
Green - Flashing
White
Blue
2 x Red Flashing
White/red flashing
OFF
1 - LED Light
Power is ON
Device is booting
Device is ready for operation
Access Point mode, (WLAN)
Failed to join Network
No connection to myABB
No power
2 - ACTIVATED/DEACTIVATED Access Point mode (WLAN on/off);
LED ON/OFF: active/inactive
3 - RESET by using a pin - press down and hold for 40 seconds or longer
Cleaning:
To clean, wipe with a clean damp cloth. DO NOT use any chemical
cleaning solutions.
FCC/IC Information
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference, including
interference that may cause unwanted operation. Modifications not expressly approved by the
manufacturer could void the user’s authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used according to the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in an installation. If this equipment does cause
harmful interference to radio or television reception, which can be tested by turning the
equipment off and on, the user is encouraged to try to correct the interference by doing one or
more of the following:
■
Reposition or move the receiving antenna.
■
Increase the distance between the equipment and the receiver.
■
Connect the equipment to an outlet on a different circuit (not the circuit used by the
receiver).
■
Consult the dealer or an experienced radio/TV technician for help.
This radio transmitter IC:23736-SAPS3US has been approved by ISED Canada to operate
with the antenna types listed below with the maximum permissible gain indicated. Antenna
types not included in this list, having a gain greater than the maximum gain indicated for that
type, are strictly prohibited for use with this device.
The device operation in the band 5150–5250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems.
This device contains WLAN Module IC 23736-SPB209A, HVIN SPB209A-BN.
External Antenna (optional):
■
ABB SAP-1-WL
■
gain: 1.5dBi
■
connector: reverse SMA
A minimum separation distance ≥ 20 cm is required between the antenna and radiating
structures of the device and nearby persons to qualify for mobile exposure limits.
Use the adapter for the enclosed DC power jack
USB-Port
USB-Port
Ethernet Connection (RJ45)
External Antenna
Setup
■
OPERATION
All the devices of the system must be correctly wired and
powered ON.
Connect to the SysAP with a smartphone, tablet, or PC via WLAN.
For additional connection options see the technical reference manual.
(Scan QR code in this instruction manual).
Detailed information about setup, network connection and
configuration is available in the technical reference manual at
http://new.abb.com/products/2CKA006200A0156/
Customer Service
800-816-7809
7:00 am - 5:30 pm, CST, Monday - Friday
elec_custserv@tnb.com
Technical Support
888-385-1221, Option 1
7:00 am - 5:00 pm, CST, Monday - Friday
lvps.support@us.abb.com
Establishing Connection via WLAN
1. Connect to the System Access Point 2.0 with WLAN (For password
see backside of the device)
2. Open the web-based configuration tool
A) Automatic within free@home app
B) Via UPnP (network settings - double click on device)
C) Via browser (enter IP address: 192.168.2.1)
3. Settings page will appear
ABB Inc.
Electrification Products
8155 T&B Boulevard
Memphis, TN 38125
NEC is a registered trademark of the National Fire Protection
Association, Quincy, Massachusetts.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 11.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2018:06:12 07:36+02:00
Create Date                     : 2018:06:12 07:36+02:00
Format                          : application/pdf
Title                           : Microsoft Word - SAP-S-3-US_Flyer-ABB_Korrekturexemplar_2018-06-12.docx
Creator                         : Michael.Bruchhaus
Document ID                     : uuid:448875ca-e7d8-4eea-8f74-61692c885524
Instance ID                     : uuid:c2dc567f-cc62-40cc-a0fd-12b160fc8854
Page Count                      : 1
Author                          : Michael.Bruchhaus
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AO6WSAP-S-3-US

Navigation menu