C MAX Asia CMP9304BC18 Bluetooth 5.0 Beacon User Manual

C-MAX Asia limited Bluetooth 5.0 Beacon

User Manual

C-MAX Beacon  Datasheet    SPEC No. C-MAX Beacon DataSheet Revision 1.8 State 2018-01-10 C-MAX printed  2018-01-10 Version English Page 1 of 8  C-MAX   Bluetooth Beacon Broadcast Device   CMP-9304BC01              《Supplier》 Company Name: C-MAX Asia Ltd.,  Address:             Unit 117, Liven House,                                61-63 King Yip Street,                                Kwun Tong, Kowloon,                                Hong Kong SAR  Tel:                    +852-2798-5182 Fax:                   +852-2798-5379
C-MAX Beacon  Datasheet   SPEC No. C-MAX Beacon DataSheet Revision 1.8 State 2018-01-10 C-MAX printed  2018-01-10 Version English Page 2 of 8  C-MAX 1  Description  The CMP-9304BC01 is a Bluetooth Low-Energy proximity beacon suitable for mass deployment by system integrators. The module advertises ID data that is compatible with common beacon standards (UUID, Major ID, and Minor ID).  An supervisor mobile APP is also available from C-MAX for over-the-air beacon settings to configure parameters such as UUID, Major ID, Minor ID, advertising intervals, measured  power levels and measured power at 1 meter. 1.1  Features    ID packet format includes:   UUID, Major ID, and Minor ID    Output power information      IPX4 water resistant     Beacon interval programmable via mobile APP for flexible power consumption management. Default interval is 1 second.   Output power programmable via mobile APP for flexible communication distance utilization. Default upon first time use is 0.4 dBm.   UUID programmable via mobile APP.   Major and Minor IDs programmable via mobile APP to suit user’s self-customization.   Measured power at 1 meter programmable via mobile APP to configure the reference RSSI at 1 meter distance 1.2  Dimensions (designations in mm)
C-MAX Beacon  Datasheet   SPEC No. C-MAX Beacon DataSheet Revision 1.8 State 2018-01-10 C-MAX printed  2018-01-10 Version English Page 3 of 8  C-MAX 1.3   Bluetooth Address  Bluetooth Address: 0C:F3:EE:XX:XX:XX   2.   Operation Manual  Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  2.1   Operational Flow                             2.2   Initial Activation  Upon first use or after new ID is programmed into the beacon device, the beacon will be in standby activation mode. The C-MAX Supervisor mobile APP has to be used to activate the beacon into normal active broadcast mode. Upon launching the APP, selecting USER mode, input the serial number of the beacon to be activated and then a simple click on “Activate” will activate the beacon which should be placed next to the Apple mobile device. If after battery is replaced, the device will remain in receive mode for 1 minute waiting for new ID to be programmed, if no new ID is programmed, the device will go into normal beacon mode, without the need for activation.   Power On (battery inserted) Receive Mode (for ID programming) Broadcast Mode (Normal Beacon Mode) Programmed new ID via APP Test Broadcast Mode (for ID verification) Sleep Mode (wait for activation) User Activation via mobile APP within 1 min after 1 min after 1 min timeout
C-MAX Beacon  Datasheet   SPEC No. C-MAX Beacon DataSheet Revision 1.8 State 2018-01-10 C-MAX printed  2018-01-10 Version English Page 4 of 8  C-MAX APP configurable device settings        2.3   iBeacon Broadcast  The normal Beacon Advertisement packet will be broadcasted every 1 second or at an interval set by the user between 100 milliseconds and 10 seconds. The broadcasting packet is according to the following standard Apple iBeacon format:    The packet consists of :   UUID (16 bytes or 32 hexadecimal characters). By default it is set to C-MAX’s UUID:                    E2C56DB5-DFFB-48D2-B060-D0F5A71096E0.   Major ID (2 bytes or 4 hexadecimal characters). By default, it is set to a value of 10000, unless C-MAX has a list of specific major IDs to be pre-programmed for the customer upon product shipment.  Minor ID (2 bytes or 4 hexadecimal characters). By default, it is set to a value of 10, unless C-MAX has a list of specific minor IDs to be pre-programmed for the customer upon product shipment.    RSSI as at 1m. As adjusted by measured power level at 1 metre distance. This parameter can be used by a mobile APP for distance computation.     E2C56DB5-DFFB-48D2-B060-D0F5A71096E0
C-MAX Beacon  Datasheet   SPEC No. C-MAX Beacon DataSheet Revision 1.8 State 2018-01-10 C-MAX printed  2018-01-10 Version English Page 5 of 8  C-MAX 2.4   Battery Level Broadcast  An additional supplement advertisement packet will be broadcasted every 5 mins by default or at an interval specified by the user within the range of 1 seconds and 3600 seconds. This allows the mobile APP to check for the battery voltage and alert for battery low conditions.  2.5   Beacon Settings Customization  If the Beacon is configured as “ENABLE PROGRAMMING”, the user can customise his own beacon parameters including the following: -  Programmable UUID o  16 bytes, each byte ranging from 0x00 to 0xFF o  Default set = E2C56DB5-DFFB-48D2-B060-D0F5A71096E0  -  Programmable Major ID o  Range from 0x0001 to 0xFFFF o  Default set = 10000  -  Programmable Minor ID o  Range from 0x0001 to 0xFFFF o  Default set = 10  -  Programmable Advertising Interval o  Input range from 600 milliseconds to 10000 milliseconds  -  Programmable TX Power Level o  Input range from 2 to 17 with definition as follows:   2   = - 17.9 dBm   3   = - 16.4 dBm   4   = - 14.6 dBm   5   = - 13.1 dBm   6   = - 11.4 dBm   7   = - 9.9 dBm   8   = - 8.4 dBm   9   = - 6.9 dBm   10 = - 5.5 dBm   11 = - 4.0 dBm   12 = - 2.6 dBm   13 = - 1.4 dBm   14 = + 0.4 dBm (default)   15 = + 2.5  dBm    16 = + 4.6 dBm   17 = + 6.2 dBm
C-MAX Beacon  Datasheet   SPEC No. C-MAX Beacon DataSheet Revision 1.8 State 2018-01-10 C-MAX printed  2018-01-10 Version English Page 6 of 8  C-MAX -  Battery Level Broadcast Interval o  Input range from 1 second to 3600 seconds o  Default set = 300 seconds (that is, 5 minutes)  -  Programmable Measured Power at 1 meter o  2’s complement of the calibrated TxPower, from 0x00 to 0xFF o  Default set = 0xC5 = -59dBm   3.   Electrical Characteristics  Specification Min Typ Max Units Condition Operating Voltage  2.3  3.0  3.3    Lithium Coin cell CR2032 battery, 25 °C , 50% humidity Battery Lifetime  (Before Activation)      50  months  CR2032 battery with 220 mAh @ 80% capacity Battery Lifetime  (After Activation) (0.6 msec broadcast interval)     14  months  CR2032 battery with 220 mAh @ 80% capacity, Beacon broadcast interval = 0.6 msec, Output power = 0.3dBm, 25 °C , 50% humidity Battery Lifetime  (After Activation) (1 sec broadcast interval)     18  months  CR2032 battery with 220 mAh @ 80% capacity, Beacon broadcast interval = 1 sec, Output power = 0.3dBm, 25 °C , 50% humidity Beacon Interval    1    sec  Default Output Power Level    +0.4    dBm  Default Average Current  (Before Activation)    5    uA  Scanning for activation Average Current  (After Activation)    18    uA  0.6 seconds iBeacon broadcast interval + 20 seconds Battery Level Advertisement Interval Range (0dBm)    30    m  At default broadcast output power and interval, 25 °C , 50% humidity Operating Temperature   -20    +60  °C  3V operating voltage
C-MAX Beacon  Datasheet   SPEC No. C-MAX Beacon DataSheet Revision 1.8 State 2018-01-10 C-MAX printed  2018-01-10 Version English Page 7 of 8  C-MAX 4. Accessories  Accessories Description Colours Available Image Silicone Wrist Band (CMP-9304BC01-WB) Black / White Wristband (-BK / -WH )  Plastic Keyfob + Neck Strap (CMP-9304BC01-KF) Black Keyfob + Blue strap (-BL)     5. Important Note   This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may  cause  harmful  interference  to  radio  communications.  However,  there  is  no  guarantee  that interference  will  not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect  the  equipment  into  an  outlet  on  circuit  different  from  that  to  which  the  receiver  is connected. —Consult the dealer or an experienced radio/TV technician for help.   5. 1 Important Note  Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)  this  device  may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any  interference received, including interference that may cause undesired operation.
C-MAX Beacon  Datasheet   SPEC No. C-MAX Beacon DataSheet Revision 1.8 State 2018-01-10 C-MAX printed  2018-01-10 Version English Page 8 of 8  C-MAX 6. FCC Radiation Exposure Statement  This equipment complies with FCC radiation exposure limit set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.       Disclaimer of Warranty Information furnished is believed to be accurate and reliable. However C-MAX assumes no responsibility, neither for the consequences of use of such information nor for any infringement of patents or other rights of third parties, which may result from its use. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. C-MAX products are not authorized for use as critical components in life support devices without express written approval of C-MAX.    Note It is not given warranty that the declared circuits, devices, facilities, components, assembly groups or treatments included herein are free from legal claims of third parties. The declared data are serving only to description of product. They are not guaranteed properties as defined by law. The examples are given without obligation and cannot give rise to any liability.   Reprinting this data sheet - or parts of it - is only allowed with a license of the publisher.  C-MAX  reserves the right to make changes on this specification without notice at any time.   C-MAX Asia Ltd                C-MAX Technology Ltd (Shenzhen) Unit 117, 1/F.,                  Unit 33H,33/F., Liven House,                   International Trade Commercial Building, 61-63 King Yip Street,                3005 Nanhu Road,   Kwun Tong, Kowloon, HK SAR             Luohu District, Shenzhen, PR China, Tel.: +852-2798-5182                Tel: +86-755-25181858 Fax: +852-2798-5379                  Fax: +86-755-25181859 e-mail: enquiry@c-max.com.hk             email: mandy@c-max.com.cn

Navigation menu