CAD Audio WX3010R BODYBACK TRANSMITTER User Manual
CAD Audio, LLC BODYBACK TRANSMITTER Users Manual
User Manual
Two-Year Limited Warranty CAD Audio hereby warrants that this product will be free of defects in material and workmanship for a period of two years from the date of purchase. In the unlikely event that a defect occurs CAD Audio will, at its option, either repair or replace with a new unit of equal or greater value. Retain proof of purchase to validate the purchase date and return it with any warranty claim. This warranty excludes exterior finish or appearance, damage from abuse, misuse of the product, use contrary to CAD Audio’s instructions or unauthorized repair. All implied warranties, merchantability, or fitness for a particular purpose is hereby disclaimed and CAD Audio hereby disclaims liability for incidental, special or consequential damages resulting from the use or unavailability of this product. This warranty gives you specific legal rights and you may have other rights that vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above exclusions and limitations may not apply to you. Note: No other warranty, written or oral is authorized by CAD Audio. Shipping Instructions Please call our customer service department at 440-349-4900 for a pre-approved return authorization number. Carefully repack the unit and return the insured package to: CAD Audio, 6573 Cochran Road, Building I, Solon, Ohio 44139. RETURNS WITHOUT A PRE-APPROVED RETURN AUTHORIZATION NUMBER WILL BE REFUSED. If outside the United States, contact your local dealer or distributor for warranty details. 13 Individuals with cardiac pacemakers and other similar medical devices should consult with their physician before using any RF devices. Though the output level of this wireless system is below 50 milliwatts, the proximity of the transmitter to the implant device could pose a threat. As with any wireless product, environmental conditions can reduce or in some cases prohibit a successful connection between the transmitter and the receiver. This device complies with Part 15 of the FCC Rules. Most users of CAD Audio wireless products in the United States do not need a license for operation. However, the rules for unlicensed operation state that this device must not operate in excess of 50 milliwatts and it must not cause harmful interference to other wireless devices, and must accept interference received from other devices. Wireless products meeting CAD factory standards adhere to these rules. The FCC reserves the right to change these rules at any time. For more information contact the FCC at 1-888-CALL-FCC (TTY: 1-888-TELL-FCC) or visit the FCC’s wireless microphone website at: www.fcc.gov/cgb/wirelessmicrophones This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autoris é e aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. 12 CADLiveTM WX3000 Introduction CADLiveTM is designed to outperform your expectations and deliver exceptional performance. Engineered to compliment the new generation of exceptional sound systems - The CADLive Series taps our Equitek studio heritage along with our live sound know-how in creating an impactful and easy-to-use line of mics. The CADLive 3000 series feature True Diversity operation to minimize multipath interference along with CADLock™ Automatic Tone Encoded Squelch to eliminate unauthorized transmissions in the signal path. Frequency agile design when partnered with ScanLink™ technology will precisely scan, select and link to the optimum channel allowing for an easy, flexible frequency plan. The CADLive handheld transmitter features metal construction and the CADLive D90 Supercardioid dynamic capsule provides a powerful, smooth and highly articulate profile. The handheld and body pack transmitters also include SoftTouch™ multi-function On-Off/Mute switches. CADLive bodypack transmitters are equipped with CADTone™ circuitry ensuring accurate reproduction of Hi-Z guitar and Lo-Z mic inputs. CADLive wireless features 10, 30, 50mW transmitter power adjustment and dynamic range up to 110dB. Receivers and transmitters are equipped with a high definition LCD display and full RF, AF, Battery Life, Mic Sensitivity and RF power metering. Receivers are housed in an all-metal chassis and supplied with single/ dual rack ears and a BNC relocation kit. Body pack systems include Equitek E19 earworn and E29 lavalier mics. Both systems are supplied with a heavy-duty carry case. The CADLiveTM WX3000 includes the following features: • True Diversity to minimize multipath interference • CADLock™ Automatic Tone Encoded Squelch eliminates unauthorized interference • Frequency agile operation for maximum frequency plan flexibility • ScanLink™ technology for instantaneous and automatic channel configuration • CADTone™ Body Pack input – Optimized Impedance interface Hi-Z for Guitar and Lo-Z for mic • Metal construction Handheld Transmitter equipped with CADLive™ D90 capsule • High Contrast LCD displays on TX and RX • Transmitters feature 10, 30, 50mW power adjustment to aid in multiple system applications • • • • Simultaneous usage of up to 15 systems per frequency band Dynamic Range > 110dB AA Batteries with up to 15 Hrs of battery life Systems ship with rack ears single/dual BNC relocation kit and durable carry case • BodyPack systems include miniature E19 Earworn, E29 Lav, WXGTR guitar cable • XLR and ¼" outputs on receiver Using the DA4090 Distribution Amplifier to Simplify Multiple-System Installations 1. BNC 50 ohm cable. 2. Power cable. 3. Power adapter. Startup Guide 1. Install new high quality alkaline batteries into transmitter, observing proper polarity. 2. Power up receiver by holding power button for one second. 3. Hold the SET button for one second to unlock the receiver menu. 4. Hold the SCAN button for one second to activate the ScanLinkTM environmental frequency analysis, which automatically selects a clear operating frequency. DA4090 DISTRIBUTION AMPLIFIER IR ScanLink IR ScanLink SET LINK SCAN IR ScanLink SET LINK IR ScanLink SET LINK SCAN SCAN SET LINK SCAN 5. Turn on the transmitter by holding the power button for one second. 6. Open the battery compartment to reveal the IR node. 7. Press the LINK button (note the IR node will illuminate). Align the two IR nodes (transmitter and receiver) at a distance of 4"-12" (ambient room light can affect distance) for a few seconds while the receiver updates the transmitter. Your system is now ScanLink'd. 11 Simultaneous Use 580 - 600MHz Band R Group Channel Frequency 580.000 584.600 600.000 586.900 588.800 590.900 597.400 581.000 583.300 588.600 598.100 581.300 595.700 591.200 599.400 Simultaneous Use 655 - 679MHz Band S Group Channel Frequency 655.400 672.275 12 677.750 656.250 661.725 663.350 10 673.425 12 678.600 655.200 660.750 12 677.225 668.675 657.800 12 678.900 10 661.500 Receiver RX3000 (Rear) 1. 2. 3. 4. DC power input jack. 12-18VDC, 300mA min, center positive. XLRM-type low-impedance balanced audio output. 1/4" [6.35mm] high-level unbalanced ouput BNC 50 ohm antenna inputs. 655 - 679MHz Band S Channelization These frequencies have been approved for use within the United States and Canada as of the date of publication of this manual. It is the user’s responsibility to comply with local regulations. 580 - 600MHz Band R CH CH Group 1 580.000 582.200 584.600 586.600 588.500 590.600 593.500 596.500 600.000 Group 6 581.300 582.800 584.500 587.100 587.900 589.800 592.700 595.700 598.200 Group 2 Group 3 580.600 582.500 581.100 583.500 582.400 584.900 583.400 586.100 584.800 586.900 586.000 588.800 586.800 590.900 594.300 594.400 597.300 597.400 Group 7 Group 8 581.900 582.100 584.100 583.600 586.500 584.300 587.700 585.300 591.000 591.200 593.700 593.900 595.800 596.000 597.700 597.900 599.300 599.500 Group 4 Group 5 580.500 580.800 581.000 583.000 583.300 584.000 584.700 585.400 585.900 587.400 586.700 589.300 588.600 591.400 590.700 595.200 594.200 598.100 Group 9 583.100 584.200 587.300 593.300 599.200 584.400 587.500 589.500 599.400 CH 10 11 12 Group 1 655.400 658.500 660.575 662.050 664.425 666.200 669.450 670.650 672.275 674.775 676.500 677.750 Group 2 Group 3 656.250 655.200 657.500 656.675 659.225 657.800 661.725 659.450 663.350 660.750 664.550 663.200 667.800 665.325 669.575 669.225 671.950 671.525 673.425 673.575 675.500 676.600 678.600 678.575 Group 4 Group 5 656.775 656.100 659.500 657.225 661.200 659.550 662.600 661.575 663.700 663.900 665.250 667.500 666.500 668.750 670.100 670.300 672.425 671.400 674.450 672.800 675.775 674.500 677.900 677.225 CH 10 11 12 Group 6 655.425 657.400 660.425 662.475 664.775 668.675 670.800 673.250 674.550 676.200 677.325 678.800 Group 7 Group 8 655.700 656.550 658.800 657.800 660.875 659.825 662.350 662.025 664.725 663.650 666.500 664.850 669.750 668.100 670.950 669.875 672.575 672.250 675.075 673.725 676.800 675.800 678.050 678.900 Group 9 Group 10 655.500 657.075 656.975 659.800 658.100 661.500 659.750 662.900 660.050 664.000 663.500 665.550 665.525 666.800 669.525 670.400 671.825 672.725 673.875 674.750 676.900 676.075 678.875 678.200 FCC WARNING This device complies with Part 74 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE 2: This device complied with FCC radiation exposure limits as set forth for an uscontrolled environment. This device should be installed and operated so that its antenna(s) are not co-located or operating in conjunction with any other antenna or transmitter
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Author : francis.zhang Create Date : 2016:06:29 14:22:56+08:00 Modify Date : 2016:07:01 17:38:20+08:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2016:07:01 17:38:20+08:00 Creator Tool : Adobe InDesign CC 2015 (Macintosh) Instance ID : uuid:a0ff600d-b90d-4689-adfd-81f9e69db645 Original Document ID : xmp.did:028011740720681195FEF0546C2EE8E3 Document ID : xmp.id:656b2030-cb63-4c15-8626-737d57128249 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:a3389bb8-3644-4bc2-9bf4-780200baac75 Derived From Document ID : xmp.did:01da391a-2fa8-4358-8fde-2747a68d8e49 Derived From Original Document ID: xmp.did:028011740720681195FEF0546C2EE8E3 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Macintosh) History Changed : / History When : 2016:04:12 10:30:51-04:00 Format : application/pdf Title : <575833303030D3A2CEC4CBB5C3F7CAE92E706466> Creator : francis.zhang Producer : Acrobat Distiller 10.0.0 (Windows) Trapped : False Page Count : 9EXIF Metadata provided by EXIF.tools