Scope of Manual The goal of this user manual is to provide the basic information to work with CAEN RFID readers. The CAENRFID is a basic library to support an easy communication with different reader types.  Change Document Record Date Revision Changes 14 Jul 2010 01 Initial release. 14 Jan 2011 02 Added Federal Communications Commission (FCC) Notice    CAEN RFID srl Via Vetraia, 11 55049 Viareggio (LU) - ITALY Tel. +39.0584.388.398  Fax +39.0584.388.959 info@caenrfid.it  www.caenrfid.it    © CAEN RFID srl – 2010 Disclaimer No  part  of  this  manual  may  be  reproduced  in  any  form  or  by  any  means,  electronic,  mechanical,  recording,  or otherwise, without the prior written permission of CAEN RFID. The information contained herein has been carefully checked and is believed to be accurate; however, no responsibility is  assumed  for  inaccuracies.  CAEN  RFID  reserves  the  right  to  modify  its  products  specifications  without  giving  any notice; for up to date information please visit www.caenrfid.it.    Federal Communications Commission (FCC) Notice (Preliminary) 1 This device was tested and found to comply with the limits set forth in Part 15 of the FCC Rules. Operation is subject to the  following  conditions:  (1)  this  device  may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any interference received including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.   This device generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, the product may cause harmful interference to radio communications. Operation of this product in a residential area is likely to cause harmful interference, in which case, the user is required to correct the interference at their own expense. The authority to operate this product is conditioned by the requirements that no modifications be made to the equipment unless the changes or modifications are expressly approved by CAEN RFID.                                                      1 This declaration only applies to FCC readers (A828US, A829US, A528, R1230CB, R1260I).
Index Scope of Manual ....................................................................................................................................................... 2 Change Document Record ........................................................................................................................................ 2 Index.......................................................................................................................................... 3 List of Tables .............................................................................................................................. 3 1 Introduction ....................................................................................................................... 4 Overview ................................................................................................................................................................... 5 SDK Design Concepts ................................................................................................................................................ 5 2 Getting Started ................................................................................................................... 7 3 Basic Operations ................................................................................................................ 9 Importing the libraries ............................................................................................................................................ 10 Reader connection/disconnection .......................................................................................................................... 10 Getting information about the connected reader .................................................................................................. 10 Setting the power level ........................................................................................................................................... 11 Inventorying RFID tags ............................................................................................................................................ 12 Optimizing the inventory process ........................................................................................................................... 13 The Q parameter ............................................................................................................................................................13 Sessions..........................................................................................................................................................................15 Reading and writing Gen2 tags ............................................................................................................................... 17 Locking Gen2 tags ................................................................................................................................................... 19 Killing Gen2 tags ..................................................................................................................................................... 20 Handling General purpose Inputs/Ouputs (GPIOs) ................................................................................................. 21  List of Tables Tab. 3.1: Recommended Q values ................................................................................................................... 13 Tab. 3.2: Persistence Time ............................................................................................................................... 15 Tab. 3.3: Lock payload and usage .................................................................................................................... 19 Tab. 3.4: Lock Action-field functionality .......................................................................................................... 19
 CAEN RFID API – User Manual 4 1 Introduction      This Chapter gives basic information about the SDK architecture. It contains these topics:  Overview  SDK Design Concepts
 CAEN RFID API– User Manual 5 Overview This guide describes the model, design concepts and the Application Software Interface (API) offered by CAEN RFID for the development of software for use, integrate and control CAEN RFID readers and accessories. CAEN  RFID  provides  a  Software  Development  Kit  (SDK)  that  includes  APIs  for  the  most  common  programming languages: Java, .NET (C# and Visual Basic) and Visual C/C++. In details, the SDK package contains:  a .NET library in the form of a DLL file with its own history file, the help file (CHM format), the .NET CF (Compact Framework) version and a demo application (with source code)  a Java library in the form of a JAR file with its own history file, the corresponding JavaDoc files (HTML format) and a demo application (with source code)  a Visual C library in the form of a DLL file, with its own history file, the stub file (.lib), the headers and a demo application (with source code)  the CAEN RFID API User Manual (this document)  the CAEN RFID API Reference Manual The  differences  between  the  APIs  are  mostly related  to  the  different  language  syntax  and  architecture  but, from  a semantic point of view, the methods/functions are maintained the same in all the languages. CAEN RFID provides also the complete  documentation of  the raw binary protocol  that can  be used to communicate with CAEN RFID readers for languages or architectures not supported by the APIs.  SDK Design Concepts A CAEN RFID reader can be seen, in a simplified model, as a box with one or more communication interfaces on the host's side and one or more antennas on the tags' side. The reader accepts commands coming from an host (a PC or any other controlling device), it uses the interface to the tag (typically one or more antennas) to perform operations on the tags and it replies to the host.  The API defines a number of classes (emulated in C language by functions and data types) in order to represent this simplified model; two of them define most of the methods and can be considered the core classes of the API itself: CAENRFIDReader and CAENRFIDLogicalSource.  CAENRFIDReader  class  provides  methods  for  the  general  reader  configuration,  host  communication  interfaces configuration, HW parameters etc.  CAENRFIDLogicalSource class defines the methods for the reader to tag communication and its configuration. Working with the host interfaces, mostly represented in the CAENRFIDReader class, is quite straightforward since they are  standard  communication  interfaces  (Ethernet,  RS232  and  similar)  while  for  the  CAENRFIDLogicalSource  class  a deeper insight is needed. One or more physical RFID antennas (called ReadPoints in the API) can be connected to a CAEN RFID, each one able to detect  tags  and  it  is  typical,  in  UHF  RFID  installations,  to  place  multiple  antennas  in  the  same  place  for  a  better coverage of the reading area. In this case, even if multiple antennas are used, the reading area is the same so, from a logical point of view, it is a single source of homogeneous information. In order to model this concept we introduced the  Logical  Source  concept  that  is  implemented  into  the  CAEN  RFID  API  with  the  CAENRFIDLogicalSource  class:  it permits  to  group  together  ReadPoints  (antennas)  that  are  logically  related.  Each  data  exchange  concerning  tags  is implemented through the CAENRFIDLogicalSource class, the case of a single antenna is a special case where a Logical Source contains a single Read Point. The  CAEN  RFID  API  permits  to  add  and  remove  Read  Points  to/from  the  Logical  Source  so  that  the  user  can  easily represent its installation.
 CAEN RFID API – User Manual 6 Up  to  the  current  revision,  the  API  handles  four  Logical  Source  (called  “Source_0”,  “Source_1”,  “Source_2”, “Source_3”) and four  Read Points  (called  “Ant0”, “Ant1”, “Ant2”,  “Ant3”) and the  default configuration is  that  each LogicalSource contains only one different ReadPoint; in the future this could change and the number of Logical Sources and Read Points could be different depending on the model of the RFID reader.  On readers with a single antenna connector, the only meaningful Logical Source is the “Source_0” one and it contains the only one available antenna “Ant0”. Note that after a reader switch off the Logical Sources composition is reset to the default configuration.
 CAEN RFID API– User Manual 7 2 Getting Started      This chapter describes the minimum steps a programmer should follow in order to operate with a CAEN RFID reader using the API.
 CAEN RFID API – User Manual 8 The minimum steps a programmer should follow in order to operate with a CAEN RFID reader using the API are the following:  Open a connection with the reader  Configuration of the logical source (optional if the default configuration is fine)  Detection of tags and other operations on the tags  Close the connection with the reader. Here below a simple but complete code snippet showing the minimum required lines of code to detect RFID tags using a CAEN  RFID reader and  the  CAEN  RFID  API. The  code is shown  using  .NET C#  programming language but  it can  be easily adapted to the other languages supported by the API.  using System; using System.Collections.Generic; using System.Linq; using System.Text; using com.caen.RFIDLibrary;  namespace ConsoleApplication1 {     class Program     {         static void Main(string[] args)         {             CAENRFIDReader MyReader = new CAENRFIDReader();              MyReader.Connect(CAENRFIDPort.CAENRFID_RS232, "COM3");              CAENRFIDLogicalSource MySource = MyReader.GetSource("Source_0");                          CAENRFIDTag[] MyTags = MySource.InventoryTag();              if (MyTags.Length > 0)             {                 for (int i = 0; i < MyTags.Length; i++)                 {                     String s = BitConverter.ToString(MyTags[i].GetId());                     Console.WriteLine(s);                 }             }             Console.WriteLine("Press a key to end the program.");             Console.ReadKey();             MyReader.Disconnect();         }     } }
 CAEN RFID API– User Manual 9 3 Basic Operations      This chapter shows the most  common operations that a  programmer can  perform using a CAEN RFID reader and the CAEN RFID API. All the example will be shown in the C# language; the Visual Basic,  Java and  C  version are  omitted since  they  differ  only at syntax level. The chapter contains these topics:  Importing the libraries  Reader connection/disconnection  Getting information about the connected reader  Setting the power level  Inventorying RFID tags  Optimizing the inventory process  Reading and writing Gen2 tags  Locking Gen2 tags  Killing Gen2 tags  Handling General purpose Inputs/Ouputs (GPIOs)
 CAEN RFID API – User Manual 10 Importing the libraries The current version of .Net and Visual C libraries have been developed using Microsoft Visual Studio 2005 and the Java library has been developed using Oracle Netbeans 6.8.  Methods to import the libraries in the application developer's projects strongly depend on the Integrated Development Environment (IDE), please refer to the documentation of the IDE in use for instructions.  Reader connection/disconnection The first operation to perform in order to start to operate with CAEN  RFID readers is to establish a  connection. The connection method depends on the physical interface available on the readers that, at now, could be an Ethernet or a serial interface. Readers with USB  interface can be considered as having a standard  RS232  serial interface since the readers implement a USB to RS232 converter internally.  The  API  provides  the  Connect  method/function  that  permits  to  establish  the  connection.  The  method  accepts  two parameters: the interface type and the address. If the interface type is serial the address will be the name of the serial port (e.g. “COM1”); if the interface is Ethernet (TCP/IP) the address will be the IP address of the reader. Here below code examples for serial port connection and for TCP/IP connection are shown.  MyReader.Connect(CAENRFIDPort.RS232,”COM1”); MyReader.Connect(CAENRFIDPort.TCP,”192.168.0.2”);  Once  connected it  is  possible  to  operate  on  the  reader  with  the  other methods.  At  the  end  of  the  operations  it  is possible to disconnect from the reader using the Disconnect method/function.  MyReader.Disconnect();  Connect and Disconnect methods are members of the CAENRFIDReader class.  Getting information about the connected reader The same  API  can be  used to control  different  type of  readers with  different  capabilities. It  is  often  useful  to  know which type of reader is connected to the application in order to access to the right features.  The API provides two methods for getting information about the connected reader: GetReaderInfo and GetFWRelease. The  first  returns  information  about  the  reader's  model  and  serial  number,  the  latter  returns  the  version  of  the firmware running into the reader itself.  Here below code examples for getting information about the connected reader are shown.  CAENRFIDReaderInfo Info = MyReader.GetReaderInfo();  String Model = Info.GetModel(); String SerialNumber = Info.GetSerialNumber(); String FWRelease = MyReader.GetFWRelease();  GetReaderInfo and GetFWRelease methods are members of the CAENRFIDReader class.
 CAEN RFID API– User Manual 11 Setting the power level Most of the CAEN RFID readers allow to regulate the emitted power. This setting is useful in order to limit the read range of the reader, to  limit the  power  as  stated by the  local  regulations or for adapt  the power depending on the antenna characteristics. The  API  provides  two  methods,  one  for  setting  the  power  (SetPower)  and  one  for  getting  the  current  power  level (GetPower). The value passed to SetPower and returned by GetPower is expressed in milliWatt (mW) and refers to the power generated by the reader at the antenna's connectors.  The  effective  radiate  power  in  mW  ERP  (Perp)  is  related  to the  conducted  RF  power  (Pw)  provided at  the  reader's connector by the following formula:  10)14.2(10LGPerpPw   where G is the antenna gain expressed in dBi and L the cable attenuation expressed in dB. So, if you require (as often is) to set a ERP power level, the above formula has to be implemented in your software in order to obtain the conducted RF power. Here below a code example that permits to obtain the desired ERP power from the antenna using the above formula and the SetPower method:  double Gain = 8.0; double Loss = 1.5; double ERPPower = 2000.0; int OutPower;  OutPower = (int)(ERPPower/Math.Pow(10,((Gain-Loss-2.14)/10))); MyReader.SetPower(OutPower);  and here  a  code  example  that  permits  to  know the current  setting of  the ERP  power using the  inverse form  of the formula and the GetPower method:  double Gain = 8.0; double Loss = 1.5; double ERPPower; int OutPower;  OutPower = MyReader.GetPower(); ERPPower = ((double)power)*((double)Math.Pow(10,((Gain-Loss-2.14)/10)));  Typically CAEN RFID readers approximate automatically the power to the nearest available power level and the same is done  for  the  minimum  and  maximum power  level.  For  the  available  power  levels  please  refer  to  the  reader's  user manual. There could be a difference between the power level set and the power level read just after the setting, this effect is normal and it is due to one or more of the following reasons:  the  set  value  was  not  exaclty  one  of  the  available  power  level  on  the  reader  so  the  real  power  level  is  the nearest available;  the formula used to convert ERP to conducted power introduced a mathematical approximation;  on some CAEN RFID readers the value returned by the GetPower method is a measurement of the power that can be affected by the accuracy of the measurement and the caracteristics of the connected antenna. GetPower and SetPower methods are members of the CAENRFIDReader class.
 CAEN RFID API – User Manual 12 Inventorying RFID tags The fundamental operation of a UHF RFID system is the inventory of the population of tags inside the reading zone of the reader's  antennas.  This  operation,  for  the  Gen2  protocol  as  for other  UHF  protocols,  consists  of  a  sequence  of commands and  replies  exchanged  between the reader  and the  tags, typically with  stringent timings between  them. CAEN RFID readers  hide the complexity of the inventory  algorithm implementing the  algorithm in the firmware and providing a macro command as interface for the user.  The CAEN RFID API provides methods in order to activate the inventory process, the simplest method that just tries to collect all the tags inside the reading zone, a more complex one with a list of options and a method to start a cycle of inventories. In  the  simplest  form  the  inventory  process  can  be  activated  simply  by  calling  the  InventoryTag  method  of  the CAENRFIDLogicalSource class. This method has no parameters at all and returns an array of CAENRFIDTag objects once a  complete  run  of  the  inventory  algorithm  is  performed  inside  the  reader  (a  CAENRFIDTag  object  is  a  software representation of the physical tag carrying the data associated to it like the EPC code, its length, the type of the tag and others). For a code sample look at the Getting Started pag. 8 of this manual. A  more  complete  version  of  the  InventoryTag  methods  takes  parameters  for  filtering  tags  and  to  activate  some optional features. The parameters used to filter the tags that have to be detected are: the memory bank (Bank), the mask  (Mask),  the  length  of  the  mask  (MaskLength)  and  the  start  address  (Position)  for  the  matching.  Using  those parameters  a  Gen2  Select  command  is  issued  before  starting  the  inventory  process  in  order  to  match  only  the interesting tags. In the matching process the Mask parameter is compared to the memory bank content starting from the address Position for MaskLength bits. Only the matching tags will be involved in the inventory process and returned back to the user by the InventoryTag method.  The user can also choose the result of the matching mechanism, i.e. can choose to return the matching tags, the not matching tags or all the tags (ignoring indeed the filter). This setting can be changed using the SetSelected_EPC_C1G2 method of the CAENRFIDLogicalSource class; possible values for its only parameter are:  EPC_C1G2_SELECTED_YES: for matching tags;  EPC_C1G2_SELECTED_NO: for non-matching tags;  EPC_C1G2_SELECTED_ALL: for all tags (no filter). An additional parameter (Flags) permits to activate special features of the inventory process, it is a bit mask where only the 5 less significant bits are used.  Bit  0  enables  (1)  or  disables  (0)  the  Return  Signal  Strength  Indicator  (RSSI)  reading  for  each  tag  for  those  readers supporting it. Bit 1 enables (1) or disables (0) the so called framed mode: if the framed mode is not enabled (default behavior) all the tags collected during the inventory process are stored into the reader's memory and returned back to the user at the end of the process. With the framed mode enabled as soon as a tag is detected is returned immediately to the user. This  behavior  results  in  a  better  responsiveness  of  the  application  especially  with  large  population  of  tags  and  it  is suggested when a small embedded reader with limited memory is used. It is mandatory to enable the framed bit when the continuous mode is enabled (see next bit description). Bit 2 enables (1) or disables (0) the continuous mode: when this bit is enabled the reader implements internally a cycle of inventories. The number of executed inventories is determined by the ReadCycle parameter that can be set with the SetReadCycle method of the CAENRFIDLogicalSource class. When ReadCycle is 0 the cycle is repeated indefinitely until an abort command is sent to the reader. Bit 3 enables (1) or disable(0) the compact data mode: when this flag is enabled, the inventory method will return back to the caller only the EPC code of the tag and all the other information like the timestamp and the type of the tag are filled with  fake  values.  This  flag  is  useful  when  it  is  necessary to reduce  the  data  exchanged  on  the  host  interface, typically when the interface is slow (low baud rate serial interfaces). Bit 4 enables (1) or disables (0) the readout of the TID during the inventory process.  A  further  option  is  to  use  an  event-based  inventory  handling  that  means  start  a  continuous  and  autonomous inventorying getting immediately the control of the thread flow to the caller. All the readings will be received by the application as  software  events.  The  user  needs  to  define  an  event  handler  that  will  take  care  of  handling  the  data coming from the tags. InventoryTag, EventInventoryTag and InventoryAbort methods are members of the CAENRFIDLogicalSource class.
 CAEN RFID API– User Manual 13 Optimizing the inventory process EPC Class1 Gen2 protocol defines a set of parameters useful for the optimization of the tags' detection, in the current paragraph we give a brief explanation of the most useful ones and we show how to work with those parameters using the CAEN RFID API.  The Q parameter The  Gen2  protocol  inventory  method  is  based  on  the  so  called  “Slotted  ALOHA”  algorithm;  without  going  into  the details of the algorithm, it is important to know that it foresees a division of the time in discrete slots. Only one tag can be  detected  for  each  slot,  if  two or  more  tags  reply  on  the  same  slot  a  collision  is  generated  and the  tags  are  not detected so a further iterations of the algorithm is needed. The number of time slots is defined in the Gen2 protocol as 2Q where Q is a parameter ranging from 0 to 15 that can be set by the user. The optimal Q value for a certain application is related to the average number of tags that are simultaneously present in the reading zone. A few tags require only a few slots, whereas many tags require many slots. Left to its own, the reader doesn’t have any way of knowing how many tags are under the antenna's field until it counts them, which may be difficult if its initial “guess” is wildly wrong. CAEN RFID reader will work faster and more efficiently if you provide an accurate starting value for Q corresponding to the expected tag population: the more are the collisions the worse are the performance of the reader in detecting the tags. The detection method implemented inside CAEN RFID readers has also  an  auto-adaptive  mechanism  in  order  to  generate  more  or  less  time  slots  when  needed  but,  starting  with  an adequate number of time slots, helps this mechaism to avoid wasting time. For reference,  the  following table gives  recommended  values of  Q that produce  reasonably efficient  inventories  for varying numbers of tags in the read zone.  Estimated number of tags Starting Q value 1 0 2 1 3 – 6 2 7 – 15 3 16 – 30 4 30 – 50 5 50 – 100 6 100 – 200 7 Tab. 3.1: Recommended Q values  CAEN RFID API provides the methods to set and read back the starting Q value: SetQ_EPC_C1G2 and GetQ_EPC_C1G2.
 CAEN RFID API – User Manual 14 Here below a code sample where the Q value is set to 3 before to start the inventory process:  using System; using System.Collections.Generic; using System.Linq; using System.Text; using com.caen.RFIDLibrary;  namespace ConsoleApplication1 {     class Program     {         static void Main(string[] args)         {             CAENRFIDReader MyReader = new CAENRFIDReader();              MyReader.Connect(CAENRFIDPort.CAENRFID_RS232, "COM3");              CAENRFIDLogicalSource MySource = MyReader.GetSource("Source_0");                          MySource.SetQ_EPC_C1G2(3);              CAENRFIDTag[] MyTags = MySource.InventoryTag();              if (MyTags.Length > 0)             {                 for (int i = 0; i < MyTags.Length; i++)                 {                     String s = BitConverter.ToString(MyTags[i].GetId());                     Console.WriteLine(s);                 }             }             Console.WriteLine("Press a key to end the program.");             Console.ReadKey();             MyReader.Disconnect();         }     } }  SetQ_EPC_C1G2 and GetQ_EPC_C1G2 methods are members of the CAENRFIDLogicalSource class.
 CAEN RFID API– User Manual 15 Sessions When  a  tag  is  singulated  by  the  “slotted  ALOHA”  algorithm  described  in  the  previous  paragraph,  it  switches automatically from an internal state A to another internal state B.  In the EPC C1G2 terminology these states are called “target A” and “target B” respectively; for our purposes we can refer to  target  A as  the non-inventoried  state and  to target B  as the  inventoried state:  singulation makes  therefore switch a tag from the non-inventoried state to the inventoried state. By  default  CAEN  RFID  readers  looks  for  non-inventoried  tags  so  once  a  tag  has  been  inventoried  it  is  no  more detectable by the reader until it returns back in the non-inventoried state. Tags return in the non-inventoried state autonomously and the times needed to return detectable can be regulated using the session  parameter.  This tuning can have  a  big impact  on the inventory  process performances especially in case of large tags' population. Gen2 protocol provides four different sessions: S0, S1, S2, S3. Each session has its own independent inventoried and non-inventoried states with its specific persistence time as shown in the following table:   Flag Required persistence S0 inventoried flag Tag energized: Indefinite Tag not energized: None S1 inventoried flag Tag energized:   Nominal temperature range: 500ms < persistence < 5s   Extended temperature range: Not specified Tag not energized:    Nominal temperature range: 500ms < persistence < 5s   Extended temperature range: Not specified S2 inventoried flag Tag energized: Indefinite Tag not energized:    Nominal temperature range: 2s < persistence    Extended temperature range: Not specified S3 inventoried flag Tag energized: Indefinite Tag not energized:    Nominal temperature range: 2s < persistence    Extended temperature range: Not specified Tab. 3.2: Persistence Time  When session S0 is used, each time the reader switches off the radiofrequency field, the tags return back in the original not-inventoried status so that they are again detectable with a successive inventory algorithm round. Since CAEN RFID readers switch off the field at the end of each inventory round, all the tags are detected again each time the inventory is repeated. This behavior can be desirable for testing purposes or when a certain level of redundancy is needed but it is typically not efficient and generate a lot of useless information. With session S1 the tags, once singulated, remain in the inventoried state for a time in the range between 500ms and 5s regardless if the tag is energized or not; during this period they are no more detectable by the subsequent inventory iterations. On large tags' populations this behavior helps to reduce the number of tags simultaneously detectable by the reader optimizing the speed of the inventory process and reducing the generated data. Sessions S2 and S3 have a longer and not explicitly limited persistence time giving the opportunity to detect tags only one time during the inventory process repetitions. These sessions are for advanced use only and are out of the scope of this manual. CAEN  RFID  API  provides  the  methods  to  set  and  read  back  the  session  parameter:  SetSession_EPC_C1G2  and GetSession_EPC_C1G2.
 CAEN RFID API – User Manual 16 Here below a code sample where the session S1 is used during the inventory process:  using System; using System.Collections.Generic; using System.Linq; using System.Text; using com.caen.RFIDLibrary;  namespace ConsoleApplication1 {     class Program     {         static void Main(string[] args)         {             CAENRFIDReader MyReader = new CAENRFIDReader();              MyReader.Connect(CAENRFIDPort.CAENRFID_RS232, "COM3");              CAENRFIDLogicalSource MySource = MyReader.GetSource("Source_0");              MySource.SetSession_EPC_C1G2(CAENRFIDLogicalSourceConstants.EPC_C1G2_SESSION_S1);              CAENRFIDTag[] MyTags = MySource.InventoryTag();              if (MyTags.Length > 0)             {                 for (int i = 0; i < MyTags.Length; i++)                 {                     String s = BitConverter.ToString(MyTags[i].GetId());                     Console.WriteLine(s);                 }             }             Console.WriteLine("Press a key to end the program.");             Console.ReadKey();             MyReader.Disconnect();         }     } }  SetSession_EPC_C1G2 and GetSession_EPC_C1G2 methods are members of the CAENRFIDLogicalSource class.
 CAEN RFID API– User Manual 17 Reading and writing Gen2 tags Gen2 tags contains a memory with the following structure:  MSB LSB   ...    10hTID [15:00] 1Fh   00hTID [31:16] 0Fh    MSB LSB Bank 11 USER EPC [15:0] ... Bank 10 TID 20hEPC [N:N-15] 2Fh10hPC [15:00] 1Fh00hCRC-16 [15:00] 0FhBank 01 EPC   MSB LSB  ... Bank 00 RESERVED 30hAccess Passwd [15:00] 3Fh 20hAccess Passwd [31:16] 2Fh10hKill Passwd [15:00] 1Fh00hKill Passwd [31:16] 0Fh The inventory process returns the EPC code that is part of the content of the EPC memory bank as a side-effect of the singulation process. All the memory content, anyway, can be read using the Gen2 Read command and the rewritable memory can be written using the Gen2 Write command.  The CAEN RFID API provides methods to read (ReadTag_EPC_C1G2) and write (WriteTag_EPC_C1G2) data into the tags' memory; the methods implement internally a Select command that is used to identify the tag on which execute the read or write command permitting to read/write into a specific tag even if multiple tags are inside the reading zone. The identification of  the tag is executed by matching the EPC  code that  can be  previously obtained by an inventory process. The other  parameters needed to  execute the read and  write command  are the memory  bank, the starting address, the data length and, in case of the write command, the data that have to be written.  The API  provides also  a  “secured” version of  those  commands that  require  a  password as an  additional  parameter. These variants of the methods have to be used in the case the Access password is set into the tag. Tags with a non-zero Access password are “protected” (in Gen2 terminology: tags with a non-zero Access password are in Open state) and the user needs to know and passes to the tag the Access password in order to write into the tag's memory (in Gen2 terminology: the tag has to switch in Secured state using the password before to allow to write).
 CAEN RFID API – User Manual 18 Here below a code sample of reading/writing data from/to the user memory:  using System; using System.Collections.Generic; using System.Linq; using System.Text; using com.caen.RFIDLibrary;  namespace ConsoleApplication1 {     class Program     {         static void Main(string[] args)         {             CAENRFIDReader MyReader = new CAENRFIDReader();              MyReader.Connect(CAENRFIDPort.CAENRFID_RS232, "COM3");              CAENRFIDLogicalSource MySource = MyReader.GetSource("Source_0");                          CAENRFIDTag[] MyTags = MySource.InventoryTag();              if (MyTags.Length > 0)             {                 for (int i = 0; i < MyTags.Length; i++)                 {                     String EPCString = BitConverter.ToString(MyTags[i].GetId());                     Console.WriteLine(EPCString);                      byte[] DataToWrite;                     ASCIIEncoding Enc = new ASCIIEncoding();                      DataToWrite = Enc.GetBytes("Hello!");                     MySource.WriteTagData_EPC_C1G2(MyTags[i], 3, 0, 6, DataToWrite);                     Console.WriteLine("Tag written!");                                          byte[] DataToRead;                     DataToRead = MySource.ReadTagData_EPC_C1G2(MyTags[i], 3, 0, 6);                     Console.WriteLine("Tag read, value = " + Enc.GetString(DataToRead));                 }               }             Console.WriteLine("Press a key to end the program.");             Console.ReadKey();             MyReader.Disconnect();         }     } } The read or write command will be executed on the first tag that replies to the reader chosen from those matching the filtering criterion. ReadTag_EPC_C1G2 and WriteTag_EPC_C1G2 methods are members of the CAENRFIDLogicalSource class.
 CAEN RFID API– User Manual 19 Locking Gen2 tags The EPCGlobal Class1 Gen2 protocol provides a mechanism to lock temporarily or permanently blocks of tag's memory. The user can lock an entire memory bank with the only exception of the Reserved memory bank where it is allowed to lock independently the Access Password and the Kill Password. The lock mechanism prevents the possibility of further modifications on locked memory banks and, only for the passwords in the Reserved memory bank, it prevents also the possibility to read back the data (the passwords). The lock command works with a single parameter called payload that includes both the lock's type (permanent or not) and the bank to lock. The format of the payload is described by the following tables:  Lock-Command Payload 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Kill Mask Access Mask EPC Mask TID Mask User Mask Kill Action Access Action EPC Action TID Action User Action                     Masks and Associated Action Fields   Kill pwd Access pwd EPC memory TID memory User memory     0 1 2 3 4 5 6 7 8 9   Mask skip/ write skip/ write skip/ write skip/ write skip/ write skip/ write skip/ write skip/ write skip/ write skip/ write     10 11 12 13 14 15 16 17 18 19   Action pwd read/ write perma lock pwd read/ write perma lock pwd write perma lock pwd write perma lock pwd write perma lock   Tab. 3.3: Lock payload and usage  pwd-write permalock Description 0 0 Associated  memory  bank  is  writeable  from  either  the  open  or  secured states 0 1 Associated memory bank is permanently writeable from either the open or secured states and may never be locked 1 0 Associated memory bank is writeable from the secured state but not from the open state 1 1 Associated memory bank is not writeable from any state pwd-read/write permalock Description 0 0 Associated  password  location  is  readable  and  writeable  from  either  the open or secured states 0 1 Associated password location is permanently readable and writeable from either the open or secured states and may never be locked 1 0 Associated password location is readable and writeable from secured state but not from open state 1 1 Associated password location is not readable or writeable from any state Tab. 3.4: Lock Action-field functionality  The CAEN RFID API provides a method (LockTag_EPC_C1G2) to lock the tag's memory contents that mimic exactly the behaviour of the protocol command. The payload parameter is implemented as a bitmask with the meaning described by the above tables. The API provides also the secured version of the LockTag_EPC_C1G2 method to be used when the Access password is set.
 CAEN RFID API – User Manual 20 Here below a code example of the LockTag_EPC_C1G2 method utilization. using System; using System.Collections.Generic; using System.Linq; using System.Text; using com.caen.RFIDLibrary;  namespace ConsoleApplication1 {     class Program     {         static void Main(string[] args)         {             CAENRFIDReader MyReader = new CAENRFIDReader();              MyReader.Connect(CAENRFIDPort.CAENRFID_RS232, "COM3");              CAENRFIDLogicalSource MySource = MyReader.GetSource("Source_0");                          CAENRFIDTag[] MyTags = MySource.InventoryTag();              if (MyTags.Length > 0)             {                 for (int i = 0; i < MyTags.Length; i++)                 {                     String EPCString = BitConverter.ToString(MyTags[i].GetId());                     Console.WriteLine(EPCString);  // +-------+-------+-------+-------+-------+-------+-------+-------+-------+-------+ // | Kill  | Acces | EPC   | TID   | User  | Kill  | Acces |  EPC  |  TID  |  User | // | Mask  | Mask  | Mask  | Mask  | Mask  | Act.  | Act.  |  Act. |  Act. |  Act. | // +---+---+---+---+---+---+---+---+---+---+---+---+-------+-------+-------+-------+ // | W | P | W | P | W | P | W | P | W | P | W | P | W | P | W | P | W | P | W | P | // +---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+ // | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | // +---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+ // // Non permanent locking of User Memory Bank //                     int Payload = 0x00802;                     MySource.LockTag_EPC_C1G2(MyTags[i], Payload);                  }             }             Console.WriteLine("Press a key to end the program.");             Console.ReadKey();             MyReader.Disconnect();         }     } LockTag_EPC_C1G2 method is a member of the CAENRFIDLogicalSource class.  Killing Gen2 tags The EPCGlobal Class1 Gen2 protocol provides a way to kill tags, that means tags, after the kill process, are  no more readable. This process is password protected: you can kill only tags with a non-zero kill password. So, once you have set the kill password using the WriteTag_EPC_C1G2 method on the RESERVED memory bank at address 0, you can use the KillTag_EPC_C1G2 method of the CAENRFIDLogicalSource class to kill the tag. The tag that has to be killed is selected just by matching the complete EPC along with the Kill Password. Differently  from  the  previously  described  methods,  there  is  not  a  secured  version  of  the  kill  method  since  the  kill command is always protected by a specialized kill password.
 CAEN RFID API– User Manual 21 Handling General purpose Inputs/Ouputs (GPIOs) Almost all CAEN RFID readers are provided along with some programmable GPIOs (for further details on GPIOs for a specific CAEN reader please refer to the correspondent reader's manual).  On each GPIO you can perform two basic operations:  Selects its direction (INPUT, OUTPUT).  Sets its value (HIGH, LOW). GPIO direction can be set and read by means of a 4 byte long bitmask used in conjunction with the GetIODirection and SetIODirection methods.  Each bit in the  bitmask  represents the  GPIO direction: a  '0' value means  INPUT,  a '1'  value means OUTPUT. A  4  byte  long  bitmask in  conjunction  with  GetIO  and  SetIO  functions  is  also  used  to  set/get  GPIO’s OUTPUT/INPUT values:   Each upset bit in the bitmask sets the correspondent GPIO to a HIGH logic voltage.  Each cleared bit in the bitmask sets the correspondent GPIO to a LOW level voltage.  High  and  low  voltage  value  varies  with  the  specific  CAEN's  reader  used.  Please  refer  to  the  specific  CAEN  reader's manual to know the effective voltage values adopted.  Let's suppose we have a reader with 4 GPIOs available and we want to program GPIO0, GPIO1 as OUTPUT and GPIO2, GPIO3 as INPUT : the bitmask associated to this settings is 0000..0011b and the code is as follows:   int MyDirections = 0x3; //hex format   MyReader.SetIODirection(MyDirections);  Coming to the GetIO and SetIO methods, we can get GPIO's input status and set GPIOs' output status as follows:  int InputVal = 0x0; int OutputVal = 0x2; //GPIO0 output value : 0,GPIO1 output value : 1  MyReader.GetIO(&InputVal); MyReader.SetIO(OutputVal);