CARRIN ELECTRONICS 9010TH Wireless Weather Station User Manual kw9078

CARRIN ELECTRONICS COMPANY LIMITED Wireless Weather Station kw9078

User Manual

Download: CARRIN ELECTRONICS 9010TH Wireless Weather Station User Manual kw9078
Mirror Download [FCC.gov]CARRIN ELECTRONICS 9010TH Wireless Weather Station User Manual kw9078
Document ID1248229
Application ID9cuhXkqH20AxbDdoRMzBMQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize13.28kB (165988 bits)
Date Submitted2010-03-04 00:00:00
Date Available2010-03-04 00:00:00
Creation Date2010-03-04 14:27:12
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2010-03-04 14:27:12
Document TitleMicrosoft Word - kw9078.doc
Document CreatorPScript5.dll Version 5.2
Document Author: christy

User manual
KW9078
Feature:
Indoor and Outdoor Temperature
Indoor and Outdoor Humidity
Time Display with Date & Day of week
433MHz RF receiving frequency.
RF channel with wireless Thermo Sensor.
Transmission range: 30 meters ( open area ).
Measuring range:
Indoor temperature : 0°C ~ +50°C
Outdoor temperature : -20°C ~ +50°C
Perpetual Calendar Up to Year 2069.
12/24Hour time display selectable.
Battery:
Main Unit
: C size battery x 2 pcs
Thermo Sensor Unit : DC 1.5 V AAA size x 2 pcs
Size :
Main Unit
: 260 x 210 x 80 mm
Thermo Sensor Unit : 65X20X85mm
Main Unit Appearance
LCD display
A1 : Date, Day of Week
A2: Time
A3: Indoor Humidity
A5: Outdoor Humidity
A4: Indoor Temperature
A6: Outdoor Temperature
Button
B1 : “Mode” button
B3: “-“ button
B5: “ALERT” button
B7:” “ ℃/℉”button
B8: “search” button
B9: “reset “ button
B2: “+12/24” button
B4: “Al ON/OFF” button
B6: “▲ “ button
Structure
C1: Wall Mount Hold
C2 : Battery compartment
KW9010-2TH
Thermo Sensor Unit Appearance.
D1: Transmission Indication LED
D3: Wall Mount Hole
D5: °C/°F” button
D7: Stand
D2: Outdoor Temperature & Humidity
D4: Battery Compartment
D6: “TX” button
Set Up:
Insert batteries.
Use a pin to press the RESET (B9) button
Manual Time Setting:
Hold “ MODE / SET” button (B1) for 3 seconds to enter Clock/Calendar setting Mode .
Press“+ ” (B2) or “- ” (B3) buttons to adjust the setting and press “MODE / SET” (B1)
button to confirm each setting.
The setting sequence is shown as follow: Hour, Minutes, Second, Year, Month/Day
sequence, Month, Day, Time Zone, Day-of-week language.
7 languages can be selected in Day-of-week, they are: German, English, Denmark, Dutch,
Italian Spanish and French,. The languages and their selected abbreviations for each day of
the week are shown in the following table.
Sunday
Monday Tuesday Wednesday Thursday Friday Saturday
German, GE
SO
MO
DI
MI
DO
FR
SA
English, EN
SU
MO
TU
WE
TH
FR
SA
Denmark, DA
SO
MA
TI
ON
TO
FR
LO
Dutch, NE
ZO
MA
DI
WO
DO
VR
ZA
Italian, IT
DO
LU
MA
ME
GI
VE
SA
Language
z
Spanish, ES
DO
LU
MA
MI
JU
VI
SA
French, FR
DI
LU
MA
ME
JE
VE
SA
The zone is used for the countries where can receive the DCF signal but the time zone is
different from the German time.
When the country time is faster than the German time for 1 hr, the zone should be set to 1.
Then the clock will automatically set 1 hour faster from the signal time received.
12/24 Hour Display mode:
Press “+(12/24)” button (B4) to select 12 or 24 hours mode.
Snooze Alarm Clock Function:
Press “MODE” button (B1) to select to view :
Time
Alarm Time (“AL“ Shown on the LCD)
When viewing the Alarm Time, hold “MODE” button (B1) for 3 seconds to enter Alarm Time
setting. Press “ +” (B4) or “-” (B7) buttons to adjust the alarm time.
Press “ALARM ON/OFF” button (B4) to switch alarm on or off. If it is on, “
the LCD.
When Alarming, press button B1, B2, B3 or B4 to stop alarming.
” shown on
Outdoor Thermo Sensor Unit Registration Procedure:
The main unit automatically starts receiving transmission from Outdoor Thermo Sensor for
outdoor temperature after are Weather condition setting .
The thermo sensor will automatically transmit temperature to the main unit after batteries
inserted. Batteries compartment (D4) of thermo sensor is locating behind the back cover,
unscrews to open.
Press “ TX “ button (D6) on the thermo sensor unit to transmit temperature & humidity to the
main unit manually. The main unit gives a “beep” sound if it received the temperature.
Thermometer:
Press “-(°C / °F)” button (B7) to select Indoor/Outdoor Temperature in Celsius mode/
Fahrenheit mode.
If the temperature is out of the measurable range, LL.L ( beyond the minimum temperature) or
HH.H (beyond the maximum temperature) will be shown on the LCD.
Temperature Alert function:
Hold “ ALERT” button for 3 seconds to enter Temperature Alert setting, Temperature’s digits
flash. Press “ ” button to select the ALERT for outdoor temperature or Indoor Temperature.
Then press “ALERT” button to confirm the selection.
Press ““▲ ” or “ ” button to set the upper ”
” and lower “
” limit of the temperature.
Press “ALERT “button to confirm the setting.
Press “ ALERT” button to set the Temperature Alert function on or off ( “
” appears on the
LCD if this function is on).
Low batteries indicator:
Low battery icon “
“appear on the display of Main unit. It means the outdoor sensor in
low battery status. The batteries should be replaced.
Note:
Use a pin to press the reset button (B9) if the Unit does not work properly.
Avoid placing the clock near interference sources/metal frames such as computer or TV sets.
The outdoor remote sensor should be taken back to Indoor when the temperature is -20C or
under. (Please also check the operation temperature of battery that is suitable for low
temperature)
The clock loses its time information when the battery is removed.
All Setting Mode will automatically exit in 15 seconds without any adjustment.
FCC Compliance Statement:
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
FCC rule:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2010:03:04 14:27:12+08:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2010:03:04 14:27:12+08:00
Format                          : application/pdf
Creator                         : christy
Title                           : Microsoft Word - kw9078.doc
Document ID                     : uuid:baa9d1e7-dcfb-43ca-af07-922bdcd27f5d
Instance ID                     : uuid:f9a77b84-7c2c-407f-853d-2418d249eec6
Page Count                      : 5
Author                          : christy
EXIF Metadata provided by EXIF.tools
FCC ID Filing: X6I-9010TH

Navigation menu