CARRIN ELECTRONICS 9078 Wireless Weather Station Receiver User Manual kw9078
CARRIN ELECTRONICS COMPANY LIMITED Wireless Weather Station Receiver kw9078
User Manual
User manual KW9078 Feature: Indoor and Outdoor Temperature Indoor and Outdoor Humidity Time Display with Date & Day of week 433MHz RF receiving frequency. RF channel with wireless Thermo Sensor. Transmission range: 30 meters ( open area ). Measuring range: Indoor temperature : 0°C ~ +50°C Outdoor temperature : -20°C ~ +50°C Perpetual Calendar Up to Year 2069. 12/24Hour time display selectable. Battery: Main Unit : C size battery x 2 pcs Thermo Sensor Unit : DC 1.5 V AAA size x 2 pcs Size : Main Unit : 260 x 210 x 80 mm Thermo Sensor Unit : 65X20X85mm Main Unit Appearance LCD display A1 : Date, Day of Week A2: Time A3: Indoor Humidity A5: Outdoor Humidity A4: Indoor Temperature A6: Outdoor Temperature Button B1 : “Mode” button B3: “-“ button B5: “ALERT” button B7:” “ ℃/℉”button B8: “search” button B9: “reset “ button B2: “+12/24” button B4: “Al ON/OFF” button B6: “▲ “ button Structure C1: Wall Mount Hold C2 : Battery compartment KW9010-2TH Thermo Sensor Unit Appearance. D1: Transmission Indication LED D3: Wall Mount Hole D5: °C/°F” button D7: Stand D2: Outdoor Temperature & Humidity D4: Battery Compartment D6: “TX” button Set Up: Insert batteries. Use a pin to press the RESET (B9) button Manual Time Setting: Hold “ MODE / SET” button (B1) for 3 seconds to enter Clock/Calendar setting Mode . Press“+ ” (B2) or “- ” (B3) buttons to adjust the setting and press “MODE / SET” (B1) button to confirm each setting. The setting sequence is shown as follow: Hour, Minutes, Second, Year, Month/Day sequence, Month, Day, Time Zone, Day-of-week language. 7 languages can be selected in Day-of-week, they are: German, English, Denmark, Dutch, Italian Spanish and French,. The languages and their selected abbreviations for each day of the week are shown in the following table. Sunday Monday Tuesday Wednesday Thursday Friday Saturday German, GE SO MO DI MI DO FR SA English, EN SU MO TU WE TH FR SA Denmark, DA SO MA TI ON TO FR LO Dutch, NE ZO MA DI WO DO VR ZA Italian, IT DO LU MA ME GI VE SA Language z Spanish, ES DO LU MA MI JU VI SA French, FR DI LU MA ME JE VE SA The zone is used for the countries where can receive the DCF signal but the time zone is different from the German time. When the country time is faster than the German time for 1 hr, the zone should be set to 1. Then the clock will automatically set 1 hour faster from the signal time received. 12/24 Hour Display mode: Press “+(12/24)” button (B4) to select 12 or 24 hours mode. Snooze Alarm Clock Function: Press “MODE” button (B1) to select to view : Time Alarm Time (“AL“ Shown on the LCD) When viewing the Alarm Time, hold “MODE” button (B1) for 3 seconds to enter Alarm Time setting. Press “ +” (B4) or “-” (B7) buttons to adjust the alarm time. Press “ALARM ON/OFF” button (B4) to switch alarm on or off. If it is on, “ the LCD. When Alarming, press button B1, B2, B3 or B4 to stop alarming. ” shown on Outdoor Thermo Sensor Unit Registration Procedure: The main unit automatically starts receiving transmission from Outdoor Thermo Sensor for outdoor temperature after are Weather condition setting . The thermo sensor will automatically transmit temperature to the main unit after batteries inserted. Batteries compartment (D4) of thermo sensor is locating behind the back cover, unscrews to open. Press “ TX “ button (D6) on the thermo sensor unit to transmit temperature & humidity to the main unit manually. The main unit gives a “beep” sound if it received the temperature. Thermometer: Press “-(°C / °F)” button (B7) to select Indoor/Outdoor Temperature in Celsius mode/ Fahrenheit mode. If the temperature is out of the measurable range, LL.L ( beyond the minimum temperature) or HH.H (beyond the maximum temperature) will be shown on the LCD. Temperature Alert function: Hold “ ALERT” button for 3 seconds to enter Temperature Alert setting, Temperature’s digits flash. Press “ ” button to select the ALERT for outdoor temperature or Indoor Temperature. Then press “ALERT” button to confirm the selection. Press ““▲ ” or “ ” button to set the upper ” ” and lower “ ” limit of the temperature. Press “ALERT “button to confirm the setting. Press “ ALERT” button to set the Temperature Alert function on or off ( “ ” appears on the LCD if this function is on). Low batteries indicator: Low battery icon “ “appear on the display of Main unit. It means the outdoor sensor in low battery status. The batteries should be replaced. Note: Use a pin to press the reset button (B9) if the Unit does not work properly. Avoid placing the clock near interference sources/metal frames such as computer or TV sets. The outdoor remote sensor should be taken back to Indoor when the temperature is -20C or under. (Please also check the operation temperature of battery that is suitable for low temperature) The clock loses its time information when the battery is removed. All Setting Mode will automatically exit in 15 seconds without any adjustment. FCC Compliance Statement: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC rule: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2010:03:04 14:27:12+08:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2010:03:04 14:27:12+08:00 Format : application/pdf Creator : christy Title : Microsoft Word - kw9078.doc Document ID : uuid:baa9d1e7-dcfb-43ca-af07-922bdcd27f5d Instance ID : uuid:f9a77b84-7c2c-407f-853d-2418d249eec6 Page Count : 5 Author : christyEXIF Metadata provided by EXIF.tools