COMFORT AIRE Air Conditioner Room (42) Manual L0705032

User Manual: COMFORT COMFORT AIRE Air Conditioner Room (42) Manual COMFORT AIRE Air Conditioner Room (42) Owner's Manual, COMFORT AIRE Air Conditioner Room (42) installation guides

Open the PDF directly: View PDF PDF.
Page Count: 24

DownloadCOMFORT  AIRE Air Conditioner Room (42) Manual L0705032
Open PDF In BrowserView PDF
6 Comm

ON/OFF

MODE

SPEEE

TIMER

TEMP/TIME

...................................................................................
j

RADS-181A

Reedioetroctionebefore inetoling,
@! !-866-217-5782 for question_ en pnrts end _ervi_e_o
Life Ioe io_trection_evnnt de pro_6der_ Pinetdlotien.
Peer toute_que_tion__oncernontle_pi6_e_et lbntretien_ _ompo_ezb 1-866..217..5782.
Leolos Inetrocdone$antes de in$t_lnrel opnroto
0010555512

Lbme_oed 1-66_.2f7-5782

el tieneprelontes _obre repoeetoeo _ervidos

Thank you for buying a dependable, energy-saving and easyotoooperate
room air conditioner. This manual contains useful information for
you to maintain, operate, install and safely use your room air conditioner°
Your air conditioner cleans, cools and dehumidifies the air in your room to
provide you with the ultimate level of comfort.

Please read instructions carefully before using the product° Also, do not
forget to fiJJout and maiJ the Product Warranty Card.

Recerd Your MedeJ aad SerieJ Number°
For aJJyour service caJJsduring the warranty period,

the foJJowing

information wiJJ be needed. Attach the sales receipt to this guide and keep
for future reference° This information can be obtained from the seriaJ pJate,
which is on your air conditioner. This is either on the cabinet (side or back),
or you may have to remove the front griJJeto Jocate it.

TABLE
RECEPTACLE
RATED VOLTS
AMPS

WALL OUTLET

AND

FUSE

TYPES

125/60
]5

250/60
20

15

20

3(}

] } The air conditioner must be connected to a proper

electricaloutletwith

the correct electrical supply. (see table)

2) Proper grounding

must be ensured to reduce the risk of shock and fire°
DO NOT CUT OR REMOVE THE GROUNDING PRONG. If you do

not have a threeoprong electric receptacle outlet in the wall, have a
certified electrician install the proper receptacle. The wall receptacle
MUST be properly grounded.
Do not use if the power cord is frayed or otherwise damaged.
Also, avoid using it if there are cracks or abrasion damage
amongthe length, plug or connector°
4} DO NOT USE AN ADAPTER OR AN EXTENSION CORD.

5) When

instaJJingyour air conditioner in a window, make sure the window

is strong enough to homdthe weight of the air conditionen You amsowant
to secure and instamlyour air conditioner properly to prevent it from
faJJing. Extra brackets andlor support may be required depending on
your window.
6} Do not bJockthe airfJow inside or outside the air conditioner

with Minds,

drapes, protectivecovers, shrubsor bushes.
7) Be carefumof sharp edges on the front and rear fins of the unit that couJd
cut and cause serious iniury.
8) Be carefuJ when Jiffing the air conditioner to instaJJor remove the unit.
AJways use two or more peopJe for this.
2

9} AJways unpJug the air conditioner before servicing it or moving it.

PAGE
A Word

Fro_

1

¢omfort°Aire

1

Product Registration
Safe,/Precautions
Warnings

4

EmectrlcamSafety

4
5

Energy

Saving

6_7

Features
Operating

8-12

Guide

Normal Operating
Operating

5

Guide

8

Sounds

Instructions

8-12

Parts

13_2G
14

Tools

14

installing Unit into A Window

15_2G

Clean and Care Gulde

21 _22

FoJJowingthe safety messages is very important.
These messages can save you from being iniured or kiJJed.
Warning

symboJs aJert you to be carefuJ and mean Danger°

AJways

foJJow instructions to be safe and reduce chances of iniury or death.
Warning

and Danger

signs wiJJprecede safety messages.

This room air conditioner must be grounded.
Grounding reduces the risk of electric shock by
providing an escape wire for the eJectriccurrent.
The power cord has a grounding wire with a
grounding pJugoPJugit into an outJetthat is
properJy instaJJedand grounded.
WARN|NG:

improper use of the grounding
pJug can resuJtin a risk of eJectric shock.
CaJJa quaJified eJectrician if you don't understand
the grounding instructions,or if you are not
sure if the air conditioner is properJy grounded°
if the waJJoutJet is not grounded, pJeasecontact an
eJectridan to have it repJaced with a properJy
grounded outJet.
Do not, under

any circumstances,

cut or remove

third (ground)
prong from the power
We strongJy advise against using an adapter

cord.

plug.

Test power pJug before each use:
1. Press "reset" button.
2 _ Press "test" button. Unit shouJd trip.
3. Press "reset" button again for use.
Do not use if above test faiJs.
Jf this device trips, the cause of the malfunction must
be corrected before further use of the device o
4

the

® Air conditioners are designed for use in a double hung "window or
through the waJJ installation only. (As applicable in your modal)
o While installing unit be sure to tilt air conditioner 5 degrees outward to
have the water drip outside the house.
install the unit on the north side,as that is normally the shaded side_This
wiJJenhance the operation of your unit.
The window has to be strong for instaJJationoExtra brackets and/or
support may be required depending on your window. (Brackets and
supports not included in aJJmodels_1
Measure the window before installing, if the window is too big for the
unit you may require professional installation°
o Use the correct electric voltage and proper ampere for the unit to run
effectively.
Only Jeta certified electrician modify your electrical outlet.
Use a dedicated line for the operation of your air conditioner to avoid
the possibility of an electrical surge°

When installing your air conditioner, make sure to seal aJJareas where
there is a possibility of air leakage°
The airflow should not be blocked, either inside by curtains, drapes or
furniture,or outside by shrubs or bushes.
Do not needlessly use an electrical light or other appliances that
produce heat.
Keep the vent dosed on the air conditioner when in the coding function.
o Keep the blinds and drapes drawn on aJJother windows.
While cooking, use an exhaust fan in the kitchen to remove the excess
heat.
Always use the correct BTUsize air conditioner to cod the room to
attain optimum efficiency.

%ii

vent
controller

side
JOUV@FS

touch pad

easy-access
filters

1 .Thermostat

3 speeds as desired

This allows you to adjust the temperature
air--the

lower the setting,the

temperature
temperature

cooler the air

With this you can set the
to your desired comfort level You

can set the temperature
F
2°Fan

of the

between 61°F and 86 °

c) DEHUMIDIFY
This enables your air conditioner to operate as
a dehumidifier as well It will remove the excess
moisture from the air to keep your room at a
comfortable,

dry stage You can use this feature

alone in case you do not wish to use the air
condifionen

Speed

With this you can control the fan speed as well
as the A/C (cooling) speed

d) ENERGY SAVER
When this feature is "On",

You have 3 levels of A/C Speed to set at your
desired level LO will circulate air at the lowest

three minutes after the compressor

cycles off

This will reduce energy consumption

and noise

velocity, MED at medium velocity and HIGH
will circulate at the maximum, velocity You have

When the compressor turns back on, the fan
will turn on at the same time In the "Off"

3 levels of Fan Speed to set at your desired
comfort level: HIGH, MED and LOW
3. Functlon

position, the fan will not shut off when the
compressor cycles off
4.Timer

Your air conditioner

Your air conditioner

has 4 Functions

a) COOL
Here the air conditioner will operate the
compressor and the desired fan speed set to
give you cold air for your comfort
b) FAN
You can run the fan without

the A/C function

on cooler days The fan can be set to run at

6

the fan will shut off

can be set to go on or off

at your desire This can be programmed
24 hours in advance

up to

5.4-Way Air FJc_w
The air directional louvers Jet you control the
direction of the airflow to the desired direction
The airflow can be directed up-down-right
left side

side-

6°Vent
The Fresh Air vent allows the air conditioner
to recirculat inside air, draw fresh air into the
room and exhaust stale air to the outside.
7.Slide

Out

Chassis

Your air conditioner

becomes

more versatile

Control

Panel lets you set the temperature

the exact temperature
1 1 .Electrostatic

to

you desire_

IFJlter (not all models)

Being constructed of high efficiency purifying
substance, active carbon fabric, electrostatic
fabric, electrostatic active carbon net and other

with this feature. You have the option to install
the unit in a window or the wall.

materials,

this air conditioner

effectively.

Its wavy structure

8. Window

capability to filter dust and smoke effectively_
Due to the retention of active carbon, it has

Install

Kit

This kit enables you to install the air conditioner
in a double hung window. Extra brackets or
support may be needed, depending
window.
9oRemote

on your

increases the

a high purifying speed capable of strong airflow.
12. How Yhe Unit Drains
On humid days with the air conditioner

Control

This fully functional

purifies the air

in use,

moisture may collect on the pan or the bottom
wireless remote allows you

of the air conditioner.

If the unit is positioned

to operate your air conditioner from a distance.
You need not get up to change the settings or
the functions, or to turn the unit on or off.

properly, the moisture will gather towards the
back of the unit.This will not affect the operation

10.LED

time. OccasionaJy

Display

Electronic

Control

Panel

of the unit and the moisture will evaporate

in

the moisture will flow over

The 4-function LED displays Room Temperature,
Temperature Setting, Timer Setting and Time

the back of the pan, but this will not affect the
operation of the unit. Never drill holes in the

Remaining

pan under any circumstance.

to Stop/Start

the unit. Electronic

lllUe d

OllliSe tiH % Se Hds

The following

sounds

are normally

® Cool airflow

movement

heard

as dictated

during

the operation

of an air conditioner.

by the set fan speed.

® Water sounds. This is normal since your air conditioner

also acts as a dehumidifier.

Thus you will hear water sounds from water drops falling on the condenser.
® As the refrigerant

flows through

the inner sealed tubing,

a rushing noise may be

Occur.

® Rattling or vibrating

noises may be heard due to poor wall or window

® High pitch compressor

Open.tim
The foiowing

Remote

installation.

sound may be heard.

IHS'I d'iOHS
are the operating

control

instructions of your dectronic

and control

After installing

panel

your air conditioner,

operations

plug it into the proper electrical

wall. Keep the vent in the closed position.
comfort

level. This fully functional

conditioner

without

air conditioner.

outlet in the

Now set the air conditioner

at your

wireless remote allows you to operate

having to get up and go to the unit. The full function

your air
feature

allows you to change the settings and turn the unit on or off from the remote itself.
This control

pad works the same as the control

pad on the air conditioner.

Fig. #1)

Fig. # 1
Remote ¢ontrd

ON/OFF

MODE

SPFFD

TIMER

i

8

(See

Afteryou plug inthe unit,ifwillperform a selftest.
Allthe displaylightswillturnon
for 3 seconds. The LED display will read"88"L If any display light fails to turn on you
may need service on the unit. After 3 seconds, the unit will automatically
stand by mode.
the On/Off

go to the

Now all lights will be off and you will have to turn"ON"

key. After pressing"On/Off",

by pressing

the unit starts to work and enters the status

of "Fan" with the low setting. You will have to press the (A) or (_) key on the Temp/Time
to set the temperature

at your desired comfort.

61°F and 86°E Once the temperature
(A) or {T) keys.The temperature
energy saver, or dehumidify
set the function

You can choose a temperature

between

is set you can raise or lower it by pressing the

setting can only be adjusted when the unit is in cooling,
mode.(See

Fig. #2) Having set the temperature,

you will

of the air conditionen

Fig, # 2
¢ontreJ Panel,

ON/OFF

MODE

SPEED

TIMER
MODE

Every time you press the MODE
SAVER and DEHUM.

(See fig.#3)

button,

SPEED

it will change

TmMER

TEMP/'liME

between FAN, COOL,

ENERGY

f

M(

coo[

SPEED

TIME_q

MED

EN_RG'
_AV_R

TEMP

/ TIME

DFF

_C

DEHUM

Once the mode function

is established,

you will have to set the fan speed. (See fig. #4)

Every time you press the SPEED button, fan speed will change

between LO\,% HIGH and

MED.
1) If you choose the COOL

mode you can run the fan in one of the 3 speeds: HIGH, MED,

or LOW.
2) For cool days you may want to run the "FAN" function.

Here the fan runs at one of 3

speeds (HIGH fan, MED fan, LOW fan) as desired by you.
3) The dehumidify
Tr: temperature

function

removes excess moisture from the air on excessively humid days.

inside the room.

Ts: the set temperature.
1) When Tr>Ts+3°F :, the compressor
2) When Ts-l°Fi

Tri

3) When Tr
Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 24
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Wed Aug 15 13:24:50 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu