COMMAX CDL-3PBR Digital Door Lock User Manual CDL 3PBR

COMMAX Co., Ltd. Digital Door Lock CDL 3PBR

Contents

User Manual CDL-3PBR

Download: COMMAX CDL-3PBR Digital Door Lock User Manual CDL 3PBR
Mirror Download [FCC.gov]COMMAX CDL-3PBR Digital Door Lock User Manual CDL 3PBR
Document ID3368450
Application IDqFWWT6/rlyzK/sdsjMg/jQ==
Document DescriptionUser Manual CDL-3PBR
Short Term ConfidentialYes
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize335.26kB (4190748 bits)
Date Submitted2017-04-24 00:00:00
Date Available2017-10-21 00:00:00
Creation Date2016-05-02 15:43:53
Producing Software3-Heights(TM) PDF Optimization Shell 4.8.25.2 (http://www.pdf-tools.com)
Document Lastmod2017-04-21 15:50:24
Document TitleUser Manual CDL-3PBR
Document CreatorAdobe InDesign CS6 (Macintosh)

DDL 영문 사용설명서.indd 1
2016. 5. 2. 오후 3:4
Overview
DDL 영문 사용설명서.indd 2
Robust Door Lock Body
KS & KC authentication give guaranted Quality and
insured Product Satisfaction.
Metalic Diecasting Design
Metal body is durable to fire and shock from outer side hazard
and damage.
Auto Lock/ Re Lock/Double Lock Function
User Friendly Function give Safety and easy usage.
Dummy Number Functions give high level safety.
Dummy Number & Real number combination give high level password.
Multi-registrations for pin-number & electronic key
It is easy to register the pin-number(up to 4) and
you can also register the electronic key(up to 30 ea).
it available to Traffice card/credit Card,too.
Multi-level volume control / mute optional Function
User can easily select 7level Volumne Control.
Light Button indicate in the dark space
You can easy to use the device using light keypad buttons.
Emergency Power Function (9V square battery)
Emergency power working even if the batteries run out completely.
Anti high-voltage / anti fireproof / anti-hacking system
It is very safe for using anti high-voltage and anti-hacking system. Also
if the temperature is higher than certain temperature, the door will be
open automatically with warning sounds under the fire.
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:4
DDL 영문 사용설명서.indd 3
Safety Cautions
Don’t install, repair or
disassemble the device
randomly.
This device is suitable
for home safety level,
other condition will
not be guarante quality.
Please read operation
manual Carefully.
ual
User Man
Don’t push or insert
the button with drill
or pin.
Change the pin-number
regularly for the safety.
Don't heavy damage
on door lock.
Do not insert the
batteries reversely.
it will be cause some
burst or leakage from
batteries .
Don’t put water into
the device.
when change battery,
please use all
new alkaline battery.
When you clean the
device, please use
the dry towel.
Do not use any other
purpose for Door lock.
www.commax.com
2016. 5. 2. 오후 3:4
CONTENTS
DDL 영문 사용설명서.indd 4
Specification
Parts Nmae
How to use
Setting Pin Number
Setting Smart Key
Setting BLE(Smartphone)
Delete setting Smartkey
Delete setting BLE
Open the gate(Keypad)
Lock the gate(Outside)
Open the gate(Inside)
Lock the gate(inside)
Force Lock Status
Easy Function
(option)
Te
Autolock Setting
Manual Setting
Sound Pause Function
Volume Control Function
Dual Authentication &Registration on/off
Built in Remocon Setting
Emergency Alarm
Function
Heat Warning
Intruder Alarm
Wir
Warning Mischef and 1min stop function
Deadbolt(mortise) Error Alarm
Battery Replacement Warning
Emergency Power
Emergency Key(key type)
Breakdown Cause and Solution
Outs
Consumer Protection Rules
Product Warranty
Batte
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:4
Specifications
Division
Install Condition
Features
Normal Fire Door
Door thickness 40mm ~ 50mm
4~12 digit number combination(Up to 4 pin number)
Pin Number
Up to 30 keys
Smart key
Access Methods
Rated Voltage
Emergency Power
Smarphone
Option
Remocon
Option
DC 6V
LR6 1.5V AA Size Alkaline Battery, 4 pc
DC 9V
Alkaline battery(Optional)
Usage and Pre installation
Product Standard
Fireproof type, Temperature sensor type, Key type, Master key door lock(D-NF-T-K-M)
Product Type
Temperature Alarm
72
±5
62
±5
(Lab Conditions)
Temperature Sensor
(Normal Conditions)
External Enclosure
Al, Zn, ABS
Internal Enclosure
Al, Zn, ABS
Material
RF Standard
Item
Frequency
Channel
Modulation
Antenna power (field strength)
RFID
13.56Mhz
1ch
ASK
Under 93.5dBuV/m@10m
Wireless Devices
447.275Mhz
1ch
FSK
Under 10mW
Features
Outside Body
Battery 4pcs
DDL 영문 사용설명서.indd 5
Inside Body
Mortise
Screw Hole Paper
Striker
Smartkey 2pcs
Screws
User manual
(Warranty)
Outdoor shaft
www.commax.com
2016. 5. 2. 오후 3:43
DDL 영문 사용설명서.indd 6
Parts Name
Outside Body Name & Function
9V Emergency Battery
(Sold Seperately)
No
Name
Features
Key Buttons
Register or change the pin number.
Open the door with registered pin number.
Battery Alarm
Open/register the electronic key.
Smartkey
Access Point
Smartkey access point for open gate. By Contracting smartkey
open the door or register smart key.
Outside Handle
handle can open or close the door.
Emergency Power
Supply Terminal
When battery fully discharged, contact 9V battery and
power on emergency power working.
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:44
Usage
Inside Body Name & Function
No
DDL 영문 사용설명서.indd 7
Name
Features
Battery Cover
Cover for battery and buttons for registration of pin number & electronic key.
Link Pack
Receiver (CDL-447RM, option)
Register Button
Use registration or change the pin number or electronic key
Mortise
Lock or close the door for installing side of door.
Dead Bolts
Lock the door to door frame.
Wrench Bolts
Prevent to shake the door.
Sub Wrench Bolts
Check for Door open or Close.
Alkaline AA Battery
Battery for main power
Manual Lock
Button
Lock the door under manual mode
Inner Handle
Open or close the door from inside.
www.commax.com
2016. 5. 2. 오후 3:4
DDL 영문 사용설명서.indd 8
How to use
Setting the Pin-number
Caution
Please set the pin number while you
open the door.
Open the inside [battery cover],push
the[Register]Button and hear "Beep"
sound shortly.
Outside
Check outside light on [Keypad]
push the button NO
Outside
Set the pin number 4 to 12 digits.
Outside
Push the [
] button
make "Beep" Sound and succeed registration
One more push the [
] button
and completed registration.
Note
Add the other pin-number, you repeat
until turn off the lights
on keypad.(Pin number can be registered up to 4 pin numbers.
Caution
The registration will be canceled when you do not push any numbers for
10 seconds after push the registration button. If you register new pinnumbers,
old one will be deleted automatically.
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:4
Setting Smart Key
Newly registered smart key or re-registred, please register
at a same time. other card not possible except provided card.
Usage
Caution
Open the battery cover,
Push the registration button once
then you can hear “Beep” sound.
Outside
Check outside light on [Keypad]
push the
on the Keypad,
direction Dimming
Outside
[Smart key]close up on [smart key input]
when succeed registration, sound beeping
Inside
Push the [Register]button,
it completed Registration.
Note
if you want to add smartkey, it available max 30keys. if you want more add up
smartkey please repeat no
Caution
DDL 영문 사용설명서.indd 9
process before turn off [Keypad]light.
it canceled [Register]button if smartkey not attach smartkey input.
if new smartkey register (Process
), previous register smart key
will be automatically deleted.
www.commax.com
2016. 5. 2. 오후 3:4
DDL 영문 사용설명서.indd 10
2016. 5. 2. 오후 3:4
Delete setting Smartkey
Open the inside [Battery cover]
push the[Register] Button
Usage
and hear "beep" sound shortly.
Outside
Chekc outside [Keypad] lightning on,
Push the
Button, light on [
]Button.
Outside
5sec
Push the [
]during 5sec.
it makes 'Beep"sound and delete
entire smartkey information.
DDL 영문 사용설명서.indd 11
www.commax.com
2016. 5. 2. 오후 3:4
How to use
(CDL - 3PBR Model Case)
Delete Setting BLE
Open the inside [Battery cover] push
the [Register] Button and hear
"Beep" sound shortly.
OutSide
Check outside light on [Keypad] push the button No
press No
Button and LED Light on [
OutSide
5sec
Press button 5sec [
Beep sound and delete whole BLE Regitstered key.
open the gate (Keypad)
Method1
DDL 영문 사용설명서.indd 12
Key pad openning
Touch [Keypad],
input [Password].
Push the [
]button and belling
beep sound Door will be released.
Note
Dummy number function will be add up head or tail to original password.
dummy No+original password
original password+dummy No
(for preventing from other person cheating password)
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:4
Open the gate (Smart Key)
Method 2
Smartkey Opening
Registered [Smart Key]close to
Usage
[Smart key] access point.
Beep sound and open the Gate.
Note
In case of Credit card/Traffic card, touch key first and then light on
[Keypad] and close to access point, it will be open the gate.
Method 3
BLE(smartphone)Opening (CDL - 3PBR Model type)
Shake on [BLE (Smartphone)]
on the access point.
Beep sound and open the oate.
Method 4
DDL 영문 사용설명서.indd 13
Remocon opening (option)
Push the [OP/CL]button on the Remocon
and open the gate.
www.commax.com
2016. 5. 2. 오후 3:4
How to use
Lock the gate (Outside)
Method 1
Auto Locking
Closing the door and lock the door
after 2second automatically.
2sec
Method 2
Manual Locking
Touch the [Keypad], door will be lock.
Open the gate
Method 1
DDL 영문 사용설명서.indd 14
Pull the inside handle
Just pull the handle,
open the door easily.
Cautio n
Do not use or install outside dragging type door
Pus
rele
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:44
Lock the gate (inside)
Method 1
Auto Locking
Closing the door and lock the door after
2 second automatically.
Method 2
Usage
2sec
Manual Locking
Push the inside
[double lock] button,
door will be manual locking.
Not e
Manual locking push the [double locking],gone to Locking status "beep"
noise and entered Double locking status.
Force Lock Status
Force Locking - Impossible by password, Smarphone, Smartkey from outside.
Method
Enther Lock Status
3sec
Push the [Double Lock] 3sec, beep souding
and enter Force Locking.
Releasing
Pull the handle from inside, Force Locking will be
released.
DDL 영문 사용설명서.indd 15
www.commax.com
2016. 5. 2. 오후 3:44
Easy Function (option)
Autolock Setting
This function is Autolock setting
Autolock Setting
This
Open the door status
Tou
Please check
beside mortise
Pop up.
Touch the ouside
[Keypad]
Input password
and push the[
button twice.
Push the No[4] and
complete Beeping
and setting
Autolocking.
Manual Setting
This
This function is Manual Lock setting
Manual Lock setting
Please check
beside mortise
Pop up.
DDL 영문 사용설명서.indd 16
Note
Open the door status
Touch the ouside
[Keypad]
Input password
and push the[
button twice.
Push the No[7] and
complete Beeping
and setting
Autolocking.
Ple
be
Po
Factory default is Auto lock setting.
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:4
nd
nd
Sound Pause Function
This function for 1time mute for preventing beeping.
Touch outside [keypad]and push the [
Usage
Method
Password: input password and push the [
]button
Card: Card access the sensor
BLE(Smartphone) : BLE access and open the gate.
Note
This function is just 1time, next time back again beep sound status
Volume Control Function
This function for Volume Level control function. (closing door status available)
Method
Volume coltrol by 7 level.
Please check
beside mortise
Pop up.
Note
DDL 영문 사용설명서.indd 17
Touch the ouside
[Keypad]
Input password
and push the [
button twice.
Push the No[3] or
No[6] button on
the [Keypad]
push the keypad of No[3] button volume up.
No[6] button volume down.
when enter Stop volume function keypad Blink
www.commax.com
2016. 5. 2. 오후 3:4
Easy Function (option)
Autolock Setting
This function is Dual authentication and registration on / off
This
Dual Authentication on/off
Touch the ouside
[Keypad]
Input password
Push the[
button twice.
Push the No[1] and
complete Beeping
and setting
Autolocking.
Input password
Push the[
button twice.
Push the No[8] and
complete Beeping
and setting
Autolocking.
Op
[Ba
the
and
sou
Registration on / off
Touch the ouside
[Keypad]
DDL 영문 사용설명서.indd 18
Note
Dual authenfication mode can open Smart key and password together.
Regstration mode can open previouse password input.
each process will be off by same process (sound : bee~leek)
Factory default is Dual Authentication and Registrtion off status.
Op
[Ba
the
and
sou
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:4
nd
nd
Built in Remocon Setting
This function is Built in remocon setting. (for only Built remocon included model)
Usage
Remocon on
Open the inside
[Battery cover] push
the[Register] Button
and hear "Beep"
sound shortly.
Note
Push the No[3]
button and
indicate Antenna
icon LED.
Push the [OP/CL]
button on the
Remocon.
Push the inside
[Register]button,
it completed
Remocon setting
Add more remocon, please repeat no 2 process before light blink off
(max 5 remocon available)
Caution
Push the [Register]button and not link with Remocon, it will be canceled
remocon setting.
New remocon Setting before Remocon will be deleted.
Remocon off
Open the inside
[Battery cover] push
the[Register] Button
and hear "Beep"
sound shortly.
DDL 영문 사용설명서.indd 19
Push the No[8] button
Push the [#] button
5sec, "beep"sound
and remocon will be
off status.
www.commax.com
2016. 5. 2. 오후 3:4
Emergency Alarm Function
Heat Warning
When a fire is detected, a high temperature of
about suspected (62Ⳅ ± 5Ⳅ), automatically
releases the locked state with strong beeps for
safety.
Op
bol
unit
do
bee
tim
Heat Warning
Abnormally in the door is locked
(For example: forcely open the gate) occurs when
the door open condition is detected
Beep noise makes 80 db (db) beeper.
Turn off heat warning & Intruder alarm
Remove battery or input [password] or attach [smart key] , it will be turn off warning and alarm.
When high temperrature status, it will be not turn off status. please cool down temperature.
Bat
Turn off alarm
Caution
ble
In case of inside body recieve sunlight, it will be warning and alarm.
so, dual authentication will be turn off automatically
Warning mischief and 1 minute stop function
If input not registered [password] or [Smart Key repeatedly entered
five times l stop operating 1 minutes with alarm.
DDL 영문 사용설명서.indd 20
Mistake input
5 times??
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:4
Deadbolt(mortise)error alarm
Opened or locked, when the dead
bolt (square clamp) of the indoor
unit body is normally taken out, or
beep" warning sound occurs three
times.
Caution
Deadbolt
(Mortise)
“BBBB”
Usage
do not enter "beep, beep beep,
If sound alarm countinuos or not workging properly. it required reallocation door lock
position, please contact installer or door lock professional company.
Battery Replacement Warning
Battery icon light on the Keypad or make sound "bleek bleek
bleek", please change battery. all battery change required.
“Bleek
Bleek
Bleek.”
Caution
Do not use mixed with used battery and New battery , Please change all battery
to new ones.
Caution
DDL 영문 사용설명서.indd 21
Wireless module use battery consumption, Battery recycle will be more
shorthen.
www.commax.com
2016. 5. 2. 오후 3:4
Emergency Alarm Function
If the
Emergency Power
Not e
Batteyr gone, impossible open the door status.
No
Buy
9V Battery.
DDL 영문 사용설명서.indd 22
9v battery
attach
Emergency
Power supply
terminal.
Press the
]button
Input
[Password].
Push the [ ]
Button again
and it beep and
unlock.
No
No
tho
Pa
au
bu
ke
“B
wa
No
Au
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:44
Break down cause and solution
If the product does not operate normally, check the following check point first.
No Power
Solution
Remarks
- Please check battery status bad or gone power and
check battery input direction
Usage
Problem
- please change new 4 alkaline Battery.
and
- Please input password short “Beep”sound one by one.
No Change Password
8 Page
- Again password register / repeat input.
- please check passwor input correctly
No open the door
though push the
]button
- When input password, keypad light off, it will be not
change password , presss the [
]button and check
keypad light on, input password again.
(if didnot input password within 7sec, it will be canceled.)
Password / Smart key
authentication success
but no open the door
- Please try 9V emergency power(square type)
keep going alarm
“Beleek x3 ”
warning sound.
- Beep indicating the battery replaced.
if you heard this alarm, please replace all new
4pcs battery.
ndle
l be
No enter
Auto Locking
DDL 영문 사용설명서.indd 23
8 Page
22 Page
- Lock can may broken. please contact installer.
21 Page
- Please reset automode.
- Sound occurs the batteries discharge and does
not work. please change all new battery
16 Page
www.commax.com
2016. 5. 2. 오후 3:4
Consumer Protection Rules
• COMMAX conducted a guarantee of the product as shown below each item,
depending on the consumer compensation regulations.
• Please install the product can not be installed by a professional installer or
authorized installer to install receive A / S if faulty.
Emergency Power
If the product fails within the first year after purchase (the warranty period), you get the free service only.
If the warranty period will be shortened half period by commerical usage.
Consumer Damage Type
Compensation
within Warranty
Functional defects in normal use occurred in 10 days
Product
Exchange
Functional defects in normal use occurred in 1month
Product
Exchange
Serviceable
No Serviceable
after warranty
same fail 3times again
Repair free
Repair charge
same file 4times again
Product exchange
Repair charge
When repair parts for repair but impossible Product
Exchange
(within the parts holding period))
Depreciation and
When repair parts are not impossible to
Depreciation and
repair (parts within the retention period)
Product
Exchange
exchange
exchange
Paid Service
1. For non-failure
2. If the consumer
fails to negligence
3. etc
DDL 영문 사용설명서.indd 24
• If it is not subject to failure, it will be service charge. Please read
the instruction manual.
• Installation issue on non-malfunction.
• Force damage on the device for lost password.
• User Handling of abuse or inappropriate repair, modification
and trouble occurs.
• Non official installer or non professional person installed and make trouble.
• Drop or make damage by cause of fault or error.
• If any trouble occurs due to natural disasters
(lightning, fire, salt damage, flood, etc.)
• If the end-life of the consumable parts (batteries, etc.)
• normal case consumer receive within 15month(including distribution period)
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:4
Product Warranty
Product Name
Product Number
Purchase (installed) Date
year
month
days
Customer's Name
Usage
Telephone
only.
20
Address
Installer Company
Telephone
Address
Installer's Name
Please keep this document for full service must present this warranty.
1) Warranty for this product is the warranty benefits to the contents listed in the warranty.
2) The warranty period is calculated from the date of purchase, so please obtain
a base purchase date.
e.
od)
DDL 영문 사용설명서.indd 25
www.commax.com
2016. 5. 2. 오후 3:4
FCC Statement
15.19:
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
15.21:
Note: The grantee is not responsible for any changes or modifications not expressly approved by
the party responsible for compliance. Such modifications could void the user’s authority to operate
the equipment.
15.105(b):
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Disclaimers
The manufacturer, importer, and distributor shall not be liable for damages including accidental and
personal injury due to the improper use or operation of this product. The information in this
user manual was written based on current product specifications. The manufacturer, iriver Limited,
is adding new complementary features and will continue to apply new technologies in the future.
Product specifications may be changed without prior notice.
iriver is not responsible for data loss due to product use.
Exposure statement
The transmitter must not be co-located or operated in conjunction with any other antenna or
transmitter. This equipment complies with the FCC RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with a minimum
distance of 20cm between the radiator and any part of your body.
DDL 영문 사용설명서.indd 27
www.commax.com
2016. 5. 2. 오후 3:4
MEMO
DDL 영문 사용설명서.indd 26
Digital Door Lock COMMAX
2016. 5. 2. 오후 3:4
DDL 영문 사용설명서.indd 27
MEMO
MEMO
www.commax.com
2016. 5. 2. 오후 3:4
DDL 영문 사용설명서.indd 28
2016. 5. 2. 오후 3:4

Source Exif Data:

EXIF Metadata provided by EXIF.tools
FCC ID Filing: CCECDL-3PBR

Navigation menu