User Manual
DDL 영문 사용설명서.indd 1 2016. 5. 2. 오후 3:4 Overview DDL 영문 사용설명서.indd 2 Robust Door Lock Body KS & KC authentication give guaranted Quality and insured Product Satisfaction. Metalic Diecasting Design Metal body is durable to fire and shock from outer side hazard and damage. Auto Lock/ Re Lock/Double Lock Function User Friendly Function give Safety and easy usage. Dummy Number Functions give high level safety. Dummy Number & Real number combination give high level password. Multi-registrations for pin-number & electronic key It is easy to register the pin-number(up to 4) and you can also register the electronic key(up to 30 ea). it available to Traffice card/credit Card,too. Multi-level volume control / mute optional Function User can easily select 7level Volumne Control. Light Button indicate in the dark space You can easy to use the device using light keypad buttons. Emergency Power Function (9V square battery) Emergency power working even if the batteries run out completely. Anti high-voltage / anti fireproof / anti-hacking system It is very safe for using anti high-voltage and anti-hacking system. Also if the temperature is higher than certain temperature, the door will be open automatically with warning sounds under the fire. Digital Door Lock COMMAX 2016. 5. 2. 오후 3:4 DDL 영문 사용설명서.indd 3 Safety Cautions Don’t install, repair or disassemble the device randomly. This device is suitable for home safety level, other condition will not be guarante quality. Please read operation manual Carefully. ual User Man Don’t push or insert the button with drill or pin. Change the pin-number regularly for the safety. Don't heavy damage on door lock. Do not insert the batteries reversely. it will be cause some burst or leakage from batteries . Don’t put water into the device. when change battery, please use all new alkaline battery. When you clean the device, please use the dry towel. Do not use any other purpose for Door lock. www.commax.com 2016. 5. 2. 오후 3:4 CONTENTS DDL 영문 사용설명서.indd 4 Specification Parts Nmae How to use Setting Pin Number Setting Smart Key Setting BLE(Smartphone) Delete setting Smartkey Delete setting BLE Open the gate(Keypad) Lock the gate(Outside) Open the gate(Inside) Lock the gate(inside) Force Lock Status Easy Function (option) Te Autolock Setting Manual Setting Sound Pause Function Volume Control Function Dual Authentication &Registration on/off Built in Remocon Setting Emergency Alarm Function Heat Warning Intruder Alarm Wir Warning Mischef and 1min stop function Deadbolt(mortise) Error Alarm Battery Replacement Warning Emergency Power Emergency Key(key type) Breakdown Cause and Solution Outs Consumer Protection Rules Product Warranty Batte Digital Door Lock COMMAX 2016. 5. 2. 오후 3:4 Specifications Division Install Condition Features Normal Fire Door Door thickness 40mm ~ 50mm 4~12 digit number combination(Up to 4 pin number) Pin Number Up to 30 keys Smart key Access Methods Rated Voltage Emergency Power Smarphone Option Remocon Option DC 6V LR6 1.5V AA Size Alkaline Battery, 4 pc DC 9V Alkaline battery(Optional) Usage and Pre installation Product Standard Fireproof type, Temperature sensor type, Key type, Master key door lock(D-NF-T-K-M) Product Type Temperature Alarm 72 ±5 62 ±5 (Lab Conditions) Temperature Sensor (Normal Conditions) External Enclosure Al, Zn, ABS Internal Enclosure Al, Zn, ABS Material RF Standard Item Frequency Channel Modulation Antenna power (field strength) RFID 13.56Mhz 1ch ASK Under 93.5dBuV/m@10m Wireless Devices 447.275Mhz 1ch FSK Under 10mW Features Outside Body Battery 4pcs DDL 영문 사용설명서.indd 5 Inside Body Mortise Screw Hole Paper Striker Smartkey 2pcs Screws User manual (Warranty) Outdoor shaft www.commax.com 2016. 5. 2. 오후 3:43 DDL 영문 사용설명서.indd 6 Parts Name Outside Body Name & Function 9V Emergency Battery (Sold Seperately) No Name Features Key Buttons Register or change the pin number. Open the door with registered pin number. Battery Alarm Open/register the electronic key. Smartkey Access Point Smartkey access point for open gate. By Contracting smartkey open the door or register smart key. Outside Handle handle can open or close the door. Emergency Power Supply Terminal When battery fully discharged, contact 9V battery and power on emergency power working. Digital Door Lock COMMAX 2016. 5. 2. 오후 3:44 Usage Inside Body Name & Function No DDL 영문 사용설명서.indd 7 Name Features Battery Cover Cover for battery and buttons for registration of pin number & electronic key. Link Pack Receiver (CDL-447RM, option) Register Button Use registration or change the pin number or electronic key Mortise Lock or close the door for installing side of door. Dead Bolts Lock the door to door frame. Wrench Bolts Prevent to shake the door. Sub Wrench Bolts Check for Door open or Close. Alkaline AA Battery Battery for main power Manual Lock Button Lock the door under manual mode Inner Handle Open or close the door from inside. www.commax.com 2016. 5. 2. 오후 3:4 DDL 영문 사용설명서.indd 8 How to use Setting the Pin-number Caution Please set the pin number while you open the door. Open the inside [battery cover],push the[Register]Button and hear "Beep" sound shortly. Outside Check outside light on [Keypad] push the button NO Outside Set the pin number 4 to 12 digits. Outside Push the [ ] button make "Beep" Sound and succeed registration One more push the [ ] button and completed registration. Note Add the other pin-number, you repeat until turn off the lights on keypad.(Pin number can be registered up to 4 pin numbers. Caution The registration will be canceled when you do not push any numbers for 10 seconds after push the registration button. If you register new pinnumbers, old one will be deleted automatically. Digital Door Lock COMMAX 2016. 5. 2. 오후 3:4 Setting Smart Key Newly registered smart key or re-registred, please register at a same time. other card not possible except provided card. Usage Caution Open the battery cover, Push the registration button once then you can hear “Beep” sound. Outside Check outside light on [Keypad] push the on the Keypad, direction Dimming Outside [Smart key]close up on [smart key input] when succeed registration, sound beeping Inside Push the [Register]button, it completed Registration. Note if you want to add smartkey, it available max 30keys. if you want more add up smartkey please repeat no Caution DDL 영문 사용설명서.indd 9 process before turn off [Keypad]light. it canceled [Register]button if smartkey not attach smartkey input. if new smartkey register (Process ), previous register smart key will be automatically deleted. www.commax.com 2016. 5. 2. 오후 3:4 DDL 영문 사용설명서.indd 10 2016. 5. 2. 오후 3:4 Delete setting Smartkey Open the inside [Battery cover] push the[Register] Button Usage and hear "beep" sound shortly. Outside Chekc outside [Keypad] lightning on, Push the Button, light on [ ]Button. Outside 5sec Push the [ ]during 5sec. it makes 'Beep"sound and delete entire smartkey information. DDL 영문 사용설명서.indd 11 www.commax.com 2016. 5. 2. 오후 3:4 How to use (CDL - 3PBR Model Case) Delete Setting BLE Open the inside [Battery cover] push the [Register] Button and hear "Beep" sound shortly. OutSide Check outside light on [Keypad] push the button No press No Button and LED Light on [ OutSide 5sec Press button 5sec [ Beep sound and delete whole BLE Regitstered key. open the gate (Keypad) Method1 DDL 영문 사용설명서.indd 12 Key pad openning Touch [Keypad], input [Password]. Push the [ ]button and belling beep sound Door will be released. Note Dummy number function will be add up head or tail to original password. dummy No+original password original password+dummy No (for preventing from other person cheating password) Digital Door Lock COMMAX 2016. 5. 2. 오후 3:4 Open the gate (Smart Key) Method 2 Smartkey Opening Registered [Smart Key]close to Usage [Smart key] access point. Beep sound and open the Gate. Note In case of Credit card/Traffic card, touch key first and then light on [Keypad] and close to access point, it will be open the gate. Method 3 BLE(smartphone)Opening (CDL - 3PBR Model type) Shake on [BLE (Smartphone)] on the access point. Beep sound and open the oate. Method 4 DDL 영문 사용설명서.indd 13 Remocon opening (option) Push the [OP/CL]button on the Remocon and open the gate. www.commax.com 2016. 5. 2. 오후 3:4 How to use Lock the gate (Outside) Method 1 Auto Locking Closing the door and lock the door after 2second automatically. 2sec Method 2 Manual Locking Touch the [Keypad], door will be lock. Open the gate Method 1 DDL 영문 사용설명서.indd 14 Pull the inside handle Just pull the handle, open the door easily. Cautio n Do not use or install outside dragging type door Pus rele Digital Door Lock COMMAX 2016. 5. 2. 오후 3:44 Lock the gate (inside) Method 1 Auto Locking Closing the door and lock the door after 2 second automatically. Method 2 Usage 2sec Manual Locking Push the inside [double lock] button, door will be manual locking. Not e Manual locking push the [double locking],gone to Locking status "beep" noise and entered Double locking status. Force Lock Status Force Locking - Impossible by password, Smarphone, Smartkey from outside. Method Enther Lock Status 3sec Push the [Double Lock] 3sec, beep souding and enter Force Locking. Releasing Pull the handle from inside, Force Locking will be released. DDL 영문 사용설명서.indd 15 www.commax.com 2016. 5. 2. 오후 3:44 Easy Function (option) Autolock Setting This function is Autolock setting Autolock Setting This Open the door status Tou Please check beside mortise Pop up. Touch the ouside [Keypad] Input password and push the[ button twice. Push the No[4] and complete Beeping and setting Autolocking. Manual Setting This This function is Manual Lock setting Manual Lock setting Please check beside mortise Pop up. DDL 영문 사용설명서.indd 16 Note Open the door status Touch the ouside [Keypad] Input password and push the[ button twice. Push the No[7] and complete Beeping and setting Autolocking. Ple be Po Factory default is Auto lock setting. Digital Door Lock COMMAX 2016. 5. 2. 오후 3:4 nd nd Sound Pause Function This function for 1time mute for preventing beeping. Touch outside [keypad]and push the [ Usage Method Password: input password and push the [ ]button Card: Card access the sensor BLE(Smartphone) : BLE access and open the gate. Note This function is just 1time, next time back again beep sound status Volume Control Function This function for Volume Level control function. (closing door status available) Method Volume coltrol by 7 level. Please check beside mortise Pop up. Note DDL 영문 사용설명서.indd 17 Touch the ouside [Keypad] Input password and push the [ button twice. Push the No[3] or No[6] button on the [Keypad] push the keypad of No[3] button volume up. No[6] button volume down. when enter Stop volume function keypad Blink www.commax.com 2016. 5. 2. 오후 3:4 Easy Function (option) Autolock Setting This function is Dual authentication and registration on / off This Dual Authentication on/off Touch the ouside [Keypad] Input password Push the[ button twice. Push the No[1] and complete Beeping and setting Autolocking. Input password Push the[ button twice. Push the No[8] and complete Beeping and setting Autolocking. Op [Ba the and sou Registration on / off Touch the ouside [Keypad] DDL 영문 사용설명서.indd 18 Note Dual authenfication mode can open Smart key and password together. Regstration mode can open previouse password input. each process will be off by same process (sound : bee~leek) Factory default is Dual Authentication and Registrtion off status. Op [Ba the and sou Digital Door Lock COMMAX 2016. 5. 2. 오후 3:4 nd nd Built in Remocon Setting This function is Built in remocon setting. (for only Built remocon included model) Usage Remocon on Open the inside [Battery cover] push the[Register] Button and hear "Beep" sound shortly. Note Push the No[3] button and indicate Antenna icon LED. Push the [OP/CL] button on the Remocon. Push the inside [Register]button, it completed Remocon setting Add more remocon, please repeat no 2 process before light blink off (max 5 remocon available) Caution Push the [Register]button and not link with Remocon, it will be canceled remocon setting. New remocon Setting before Remocon will be deleted. Remocon off Open the inside [Battery cover] push the[Register] Button and hear "Beep" sound shortly. DDL 영문 사용설명서.indd 19 Push the No[8] button Push the [#] button 5sec, "beep"sound and remocon will be off status. www.commax.com 2016. 5. 2. 오후 3:4 Emergency Alarm Function Heat Warning When a fire is detected, a high temperature of about suspected (62Ⳅ ± 5Ⳅ), automatically releases the locked state with strong beeps for safety. Op bol unit do bee tim Heat Warning Abnormally in the door is locked (For example: forcely open the gate) occurs when the door open condition is detected Beep noise makes 80 db (db) beeper. Turn off heat warning & Intruder alarm Remove battery or input [password] or attach [smart key] , it will be turn off warning and alarm. When high temperrature status, it will be not turn off status. please cool down temperature. Bat Turn off alarm Caution ble In case of inside body recieve sunlight, it will be warning and alarm. so, dual authentication will be turn off automatically Warning mischief and 1 minute stop function If input not registered [password] or [Smart Key repeatedly entered five times l stop operating 1 minutes with alarm. DDL 영문 사용설명서.indd 20 Mistake input 5 times?? Digital Door Lock COMMAX 2016. 5. 2. 오후 3:4 Deadbolt(mortise)error alarm Opened or locked, when the dead bolt (square clamp) of the indoor unit body is normally taken out, or beep" warning sound occurs three times. Caution Deadbolt (Mortise) “BBBB” Usage do not enter "beep, beep beep, If sound alarm countinuos or not workging properly. it required reallocation door lock position, please contact installer or door lock professional company. Battery Replacement Warning Battery icon light on the Keypad or make sound "bleek bleek bleek", please change battery. all battery change required. “Bleek Bleek Bleek.” Caution Do not use mixed with used battery and New battery , Please change all battery to new ones. Caution DDL 영문 사용설명서.indd 21 Wireless module use battery consumption, Battery recycle will be more shorthen. www.commax.com 2016. 5. 2. 오후 3:4 Emergency Alarm Function If the Emergency Power Not e Batteyr gone, impossible open the door status. No Buy 9V Battery. DDL 영문 사용설명서.indd 22 9v battery attach Emergency Power supply terminal. Press the ]button Input [Password]. Push the [ ] Button again and it beep and unlock. No No tho Pa au bu ke “B wa No Au Digital Door Lock COMMAX 2016. 5. 2. 오후 3:44 Break down cause and solution If the product does not operate normally, check the following check point first. No Power Solution Remarks - Please check battery status bad or gone power and check battery input direction Usage Problem - please change new 4 alkaline Battery. and - Please input password short “Beep”sound one by one. No Change Password 8 Page - Again password register / repeat input. - please check passwor input correctly No open the door though push the ]button - When input password, keypad light off, it will be not change password , presss the [ ]button and check keypad light on, input password again. (if didnot input password within 7sec, it will be canceled.) Password / Smart key authentication success but no open the door - Please try 9V emergency power(square type) keep going alarm “Beleek x3 ” warning sound. - Beep indicating the battery replaced. if you heard this alarm, please replace all new 4pcs battery. ndle l be No enter Auto Locking DDL 영문 사용설명서.indd 23 8 Page 22 Page - Lock can may broken. please contact installer. 21 Page - Please reset automode. - Sound occurs the batteries discharge and does not work. please change all new battery 16 Page www.commax.com 2016. 5. 2. 오후 3:4 Consumer Protection Rules • COMMAX conducted a guarantee of the product as shown below each item, depending on the consumer compensation regulations. • Please install the product can not be installed by a professional installer or authorized installer to install receive A / S if faulty. Emergency Power If the product fails within the first year after purchase (the warranty period), you get the free service only. If the warranty period will be shortened half period by commerical usage. Consumer Damage Type Compensation within Warranty Functional defects in normal use occurred in 10 days Product Exchange Functional defects in normal use occurred in 1month Product Exchange Serviceable No Serviceable after warranty same fail 3times again Repair free Repair charge same file 4times again Product exchange Repair charge When repair parts for repair but impossible Product Exchange (within the parts holding period)) Depreciation and When repair parts are not impossible to Depreciation and repair (parts within the retention period) Product Exchange exchange exchange Paid Service 1. For non-failure 2. If the consumer fails to negligence 3. etc DDL 영문 사용설명서.indd 24 • If it is not subject to failure, it will be service charge. Please read the instruction manual. • Installation issue on non-malfunction. • Force damage on the device for lost password. • User Handling of abuse or inappropriate repair, modification and trouble occurs. • Non official installer or non professional person installed and make trouble. • Drop or make damage by cause of fault or error. • If any trouble occurs due to natural disasters (lightning, fire, salt damage, flood, etc.) • If the end-life of the consumable parts (batteries, etc.) • normal case consumer receive within 15month(including distribution period) Digital Door Lock COMMAX 2016. 5. 2. 오후 3:4 Product Warranty Product Name Product Number Purchase (installed) Date year month days Customer's Name Usage Telephone only. 20 Address Installer Company Telephone Address Installer's Name Please keep this document for full service must present this warranty. 1) Warranty for this product is the warranty benefits to the contents listed in the warranty. 2) The warranty period is calculated from the date of purchase, so please obtain a base purchase date. e. od) DDL 영문 사용설명서.indd 25 www.commax.com 2016. 5. 2. 오후 3:4 FCC Statement 15.19: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 15.21: Note: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment. 15.105(b): Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Disclaimers The manufacturer, importer, and distributor shall not be liable for damages including accidental and personal injury due to the improper use or operation of this product. The information in this user manual was written based on current product specifications. The manufacturer, iriver Limited, is adding new complementary features and will continue to apply new technologies in the future. Product specifications may be changed without prior notice. iriver is not responsible for data loss due to product use. Exposure statement The transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. DDL 영문 사용설명서.indd 27 www.commax.com 2016. 5. 2. 오후 3:4 MEMO DDL 영문 사용설명서.indd 26 Digital Door Lock COMMAX 2016. 5. 2. 오후 3:4 DDL 영문 사용설명서.indd 27 MEMO MEMO www.commax.com 2016. 5. 2. 오후 3:4 DDL 영문 사용설명서.indd 28 2016. 5. 2. 오후 3:4
Source Exif Data:
EXIF Metadata provided by EXIF.tools