CalAmp Wireless Networks 4048551 UHF Wireless Radio Modem User Manual 6f

CalAmp Wireless Networks Corporation UHF Wireless Radio Modem Users Manual 6f

Users Manual 6f

Download: CalAmp Wireless Networks 4048551 UHF Wireless Radio Modem User Manual 6f
Mirror Download [FCC.gov]CalAmp Wireless Networks 4048551 UHF Wireless Radio Modem User Manual 6f
Document ID1961676
Application IDyfbGXuepCguy4kBuoPZ26g==
Document DescriptionUsers Manual 6f
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize332.4kB (4154989 bits)
Date Submitted2013-05-09 00:00:00
Date Available2013-05-10 00:00:00
Creation Date2013-04-24 11:51:40
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2013-04-24 11:51:40
Document TitleUsers Manual 6f
Document CreatorMicrosoft® Office Word 2007
Document Author: Terri Grimm

INTEGRA-TR™
WIRELESS MODEM FOR LICENSED SPECTRUM
USER MANUAL
PN 001-4008-100 REV 5
NOVEMBER 2012
REVISION HISTORY
Rev 0
June 2011
Initial Release.
Rev 1
August 2011
Changed Dual Band references to Dual IF, sections 1.6 and 1.8.
Deleted Synthesizer reference, section 4.3.1.3.
Rev 2
January 2012
Added VHF Dual Band specifications and part numbers, splinter channel frequencies and FCC/IC indicators.
Rev 3
April 2012
Corrected part numbers in section 1.6.
Rev 4
September 2012
Updated VHF model numbers, FCC and IC Emission Designators.
Rev 5
November 2012
Added the 12.5/6.25 kHz bandwidths for the UHF Integra.
Rev 6
February 2013
Corrected errors in Table 4 regarding the 2424048351 and 2424048551 Models.
Change the UHF RF Exposure Compliance Requirements table
Important Notices
Because of the nature of wireless communication, transmission and reception of data can never be guaranteed. Data may
be delayed, corrupted (i.e., have errors), or be totally lost. Significant delays or losses of data are rare when wireless devices
such as the Integra-TR are used in a normal manner with a well-constructed network. Integra-TR should not be used in
situations where failure to transmit or receive data could result in damage of any kind to the user or any other party,
including but not limited to personal injury, death, or loss of property. CalAmp accepts no responsibility for damages of any
kind resulting from delays or errors in data transmitted or received using Integra-TR, or for the failure of Integra-TR to
transmit or receive such data.
This document provides the information required for the operation and preventive maintenance of the Integra-TR
integrated wireless modem. This manual is intended for system designers, installers and maintenance technicians. The
Field Programming Software for the Integra is the professional service installer interface. The Field Programming
Software should never be made available to unqualified personnel.
Copyright Notice
© 2011 CalAmp Corp. All rights reserved.
Products offered may contain software proprietary to CalAmp. The offer of supply of these products and services does not
include or infer any transfer of ownership. No part of the documentation or information supplied may be divulged to any
third party without the express written consent of CalAmp. CalAmp reserves the right to update its products, software, or
documentation without obligation to notify any individual or entity. Product updates may result in differences between the
information provided in this manual and the product shipped.
RF Exposure Compliance Requirements
The Integra-TR radio is intended for use in the Industrial Monitoring and Control and SCADA markets. The
Integra-TR unit must be professionally installed and must ensure a minimum separation distance listed in the
table below between the radiating structure and any person. An antenna mounted on a pole or tower is the
typical installation and in rare instances, a 1/2-wave whip antenna is used.
Antenna Gain
Min Safety Distance (cm @max power)
5 dBi
10 dBi
15 dBi
VHF
79.3 cm
141.0 cm
250.8 cm
UHF
74.8 cm
133 cm
236.4 cm
900 MHz
45.0 cm
80.1 cm
142.5 cm
It is the responsibility of the user to guarantee compliance with the FCC MPE regulations when operating this device in a
way other than described above.
Integra-TR uses a low power radio frequency transmitter. The concentrated energy from an antenna may pose a health
hazard. People should not be in front of the antenna when the transmitter is operating.
The installer of this equipment must ensure the antenna is located or pointed such that it does not emit an RF field in
excess of Health Canada limits for the general population. Recommended safety guidelines for the human exposure to radio
frequency electromagnetic energy are contained in the Canadian Safety Code 6 (available from Health Canada) and the
Federal Communications Commission (FCC) Bulletin 65.
Any changes or modifications not expressly approved by the party responsible for compliance (in the country where used)
could void the user's authority to operate the equipment.
Table of Contents
PRODUCT OVERVIEW ........................................................................................................................................................... 6
1.1
General Description ..................................................................................................................................................... 6
1.2
Operational Characteristics ......................................................................................................................................... 6
1.3
Physical Description ..................................................................................................................................................... 7
1.4
Front Panel ................................................................................................................................................................... 7
1.4.1
Antenna Connector .............................................................................................................................................. 7
1.4.2
LED Indicators ...................................................................................................................................................... 7
1.4.3
COM Port ............................................................................................................................................................. 8
1.4.4
Setup Port ............................................................................................................................................................ 9
1.5
Rear Panel .................................................................................................................................................................... 9
1.5.1
Heat Sink ............................................................................................................................................................ 10
1.5.2
Power – I/O Connector ...................................................................................................................................... 10
1.6
Part Number Breakdown ........................................................................................................................................... 10
1.6.1
Transceiver Identification .................................................................................................................................. 12
1.7
Accessories and Options ............................................................................................................................................ 12
1.8
Specifications ............................................................................................................................................................. 13
Getting Started .................................................................................................................................................................. 15
2.1
Device Connections.................................................................................................................................................... 15
2.2
Field Programming Software ..................................................................................................................................... 15
2.2.1
Installing the FPS ................................................................................................................................................ 16
2.2.2
Using the FPS ..................................................................................................................................................... 17
Network Applications ........................................................................................................................................................ 18
3.1
RF Path and Communications Range ......................................................................................................................... 18
3.2
Common Architecural Characteristics ....................................................................................................................... 18
3.2.1
Point-to-Point System ........................................................................................................................................ 18
3.2.2
Point-to-Multipoint System ............................................................................................................................... 19
3.2.3
Extending a Landline (Tail Circuit) ...................................................................................................................... 21
Integra-TR Field Programming Software ........................................................................................................................... 22
4.1
Integra-TR Programmer Window ............................................................................................................................... 22
4.2
File Menu ................................................................................................................................................................... 22
4.3
Edit Menu................................................................................................................................................................... 23
4.3.1
Setup Modem/Radio Parameters ...................................................................................................................... 24
4.3.2
Version Request ................................................................................................................................................. 33
4.3.3
List Information .................................................................................................................................................. 34
4.3.4
Apply Integra Reset ............................................................................................................................................ 34
4.3.5
Program Comment/ID ........................................................................................................................................ 34
4.3.6
Program Parameters .......................................................................................................................................... 35
4.3.7
Read Parameters ................................................................................................................................................ 36
4.3.8
Copy Parameters ................................................................................................................................................ 36
4.4
Utilities Menu ............................................................................................................................................................ 36
4.4.1
Port Settings ....................................................................................................................................................... 37
4.4.2
Swap COM Ports ................................................................................................................................................ 40
4.4.3
Port Statistics ..................................................................................................................................................... 40
4.4.4
Offline Link Test ................................................................................................................................................. 42
4.4.5
Offline Diagnostics ............................................................................................................................................. 43
4.4.6
Online Diagnostics ............................................................................................................................................. 46
4.4.7
Diagnostic IDs and Alarms.................................................................................................................................. 49
4.4.8
User Test ............................................................................................................................................................ 50
4.4.9
Packet Test ......................................................................................................................................................... 52
4.4.10 Array Test ........................................................................................................................................................... 54
4.4.11 Ping Test ............................................................................................................................................................. 56
4.4.12 ASCII/Hex Terminal ............................................................................................................................................ 58
4.5
Program Code Menu .................................................................................................................................................. 60
Network Optimization ....................................................................................................................................................... 61
5.1
Choose the best protocol ........................................................................................................................................... 61
5.2
Check timer settings .................................................................................................................................................. 61
5.3
Avoid flow control ...................................................................................................................................................... 61
5.4
Use the highest suitable port baud rate .................................................................................................................... 61
5.5
Evaluate the need for online diagnostics ................................................................................................................... 61
5.6
Interpreting RSSI Readings ......................................................................................................................................... 61
5.7
Interpreting Power Readings ..................................................................................................................................... 62
5.8
swr and Reverse Power .............................................................................................................................................. 62
DEFINITIONS ...................................................................................................................................................................... 63
1
PRODUCT OVERVIEW
This document provides the information required for the operation and preventive maintenance of the Integra-TR
integrated wireless modem. This manual is intended for system designers, installers and maintenance technicians. The
Field Programming Software for the Integra is the professional service installer interface. The Field Programming
Software should never be made available to unqualified personnel.
1.1
GENERAL DESCRIPTION
Integra-TR is a high-speed transparent integrated wireless modem. It is FCC refarming compliant and designed specifically
to fit the needs of SCADA, telemetry and control applications. Integra-TR provides the communication links to data
equipment for installations where wired communication is impractical.
Integra-TR works with most makes and models of remote terminal units (RTU) and programmable logic controllers (PLC)
and their protocols. Configuration settings allow tailoring for a variety of applications. Integra-TR supports:
Point to point Master-Remote or Peer-to-Peer configurations in simplex or half-duplex modes.
Point to multipoint Master-Remote configuration in simplex or half-duplex modes and offers full-duplex in dualunit configuration. These configurations are available as I-Base products. Contact your CalAmp Representative for
details.
1.2
OPERATIONAL CHARACTERISTICS
Integra-TR has the following operational characteristics:
















Selectable network speeds of 4800 and 9600 b/s for half channel units as well as 4800, 9600 and 19200 b/s for full
channel units
Backward compatible with the Integra-T for bit rate of 4800 and 9600 b/s (full channel units only)
One COM port for connection to DTE. Speed of 1200 - 19200 baud
One Setup port for configuration and diagnostics (speed fixed to 9600 baud, 8 bit, no parity, 1 stop bit)
Built-in 5-watt transceiver (adjustable 1-5 watts), operating in the VHF, UHF or 900 MHz communications bands.
Half-duplex or simplex operation
Fully transparent operation with error-free data delivery
Allows transmission of “break” characters
DOX (Data Operated Transmit) or RTS mode
Stations may be set as “master” or “remote” to prevent remote stations from hearing each other in a simplex RF
configuration
Full local and remote diagnostics
Two configurable I/O lines programmable as either 8-bit analog inputs or digital outputs
12 VDC, negative ground device
CWID provides the ability to program the unit to periodically identify itself on the air by sending the FCC Station ID
in Morse code
Disable Tx w/Carrier Present configures the unit to prevent transmission when the radio channel is busy
Low power consumption modes: “sleep” and “suspend” modes (< 20 mA)
Multi-channel capability under system PLC control provides advanced network monitoring
Page | 6
1.3
PHYSICAL DESCRIPTION
Integra-TR consists of a logic PCB (which includes modem circuitry) and a radio module. Each logic PCB and radio module
are matched together and characterized in the factory to optimize performance as an intelligent unit. The two boards then
slide into the rails of an extruded aluminum case.
DTE connection is made via a front panel connector. Power is applied through a rear panel 4-pin connector which includes
two programmable analog connections usable as inputs or outputs.
The unit is not hermetically sealed and should be mounted in a suitable enclosure when dust and/or a corrosive
atmosphere are anticipated. Physically, there are no external switches or adjustments. All operating parameters are set
using the Field Programming Software.
1.4
FRONT PANEL
Integra-TR front panel elements are described in Figure 1 - Integra TR Front Panel Figure 1.
Figure 1 - Integra TR Front Panel
1.4.1 ANTENNA CONNECTOR
Integra-TR antenna connector is a female 50-ohm SMA- type. Units operating with a rubber duck connected directly to the
antenna connector may exhibit unusual operating characteristics and high levels of reverse power.
1.4.2 LED INDICATORS
Integra-TR has four two-color LED indicators. Their functions are shown in Table 1. LED indicators may vary during startup.
Table 1 - LEDs
LED
RUN/PWR
Color
Functions
Green
Normal operation
Flash Yellow and Green
Setup mode or loading new application or new bootloader
Flash Red
Firmware error (Contact Technical Support)
Red
CPU or PROM failure (Contact Technical Support)
Page | 7
CS/SYN
RX/TX
RD/TD
Off
No RF RX carrier
Green
Receive carrier present
Red
(Reserved)
Off
No RF RX carrier
Green
Receiving network data
Yellow
Synthesizer unlocked
Red
Transmitter is on
Off
Idle
Green
RX data outgoing from RS-232 port
Red
TX data incoming at RS-232 port (or Buffered in CSMA Mode)
1.4.3 COM PORT
Integra-TR is configured as DCE. DTE devices should be connected using a nine-conductor pin-to-pin straight cable (PN 6974008-408). Some RTUs or PLCs may require a special cable to route the signals correctly. Refer to your data equipment
documentation package.
DTE baud rates from 1200 to 19200 are supported. Integra-TR's are factory set for or 9600 b/s, 8 bits, no parity, and 1 stop
bit. Unless required by your operating protocol, we advise restricting port speed to be equal to or less than the RF network
speed.
Table 2 - COM Port Signals
Pin
Name
Function
DCD
Output: Always asserted or asserted when receive RF carrier present (selectable via Field
Programming Software)
RXD
Output: Data from Integra-TR to DTE
TXD
Input: Data from DTE to Integra-TR
DTR
Input: Ignored
GND
Signal and chassis ground
DSR
Output: always positive
RTS
Input: Used as a “begin transmission” signal in RTS mode
CTS
Output: Used for handshaking in RTS mode and used for flow control in DOX mode RTS mode: RTS
to CTS delay in 4 ms DOX mode: CTS always asserted except when data overflow is detected
RI
Not internally connected, reserved
The DE-9F pin out is shown in Figure 2 for reference.
Figure 2 - COM and Setup Port Connectors Pin Locations
Page | 8
For DTE that lack RTS control, Integra-TR can operate in DOX (Data Operated Transmit) mode with only Transmit Data,
Receive Data and Ground. This 3-wire interface is shown in Figure XX.
Figure 3 - 3-wire Interface
1.4.4 SETUP PORT
The Setup port uses a DE-9 female connector configured as DCE. Signals are described in Table 3.
Table 3 - Setup Port Signals
Pin
Name
Function
DCD
Tied directly to DTR
RXD
Data from Integra-TR to setup PC
TXD
Data from setup PC to Integra-TR
DTR
Tied directly to DCD
GND
Signal and chassis ground
DSR
Output: always positive (asserted)
RTS
Tied to CTS
CTS
Tied to RTS
RI
Not internally connected, reserved
The Setup port uses a proprietary communications protocol designed to work with the Integra-TR Field Programming
Software program. It is also designed to provide alpha numeric (ASCII) diagnostics information when connected to a PC
terminal emulator.
1.5
REAR PANEL
Figure 4 - Integra-TR Rear Panel
Page | 9
1.5.1 HEAT SINK
The rear panel heat sink is essential for proper operation of the Integra-TR transmitter. The unit must be mounted in a
location that permits free air circulation past the heat sink. Cooling will be best if the fins are vertical.
1.5.2 POWER – I/O CONNECTOR
The Integra-TR power requires a regulated power source of 13.3 VDC nominal (10-16 VDC MAX) negative ground with a 3.0
A rating. An internal surface-mount 3A fuse (not field-replaceable) and a crowbar diode protect the main RF power
components from reverse polarity. Application of more than 16 VDC will damage the unit and is not covered by the
warranty.
The 4-pin power/analog connector pin out is shown in Figure 5.
Figure 5 - I/O Connector
Note: If I/O connections are not used the green and white wires should be cut back and/or taped to prevent contact (power
I/O cable part number 697-4008001 see Table 5).
1.6
PART NUMBER BREAKDOWN
The following table provides a breakdown of the Integra-TR part number.
Table 4- Integra-TR Part Number Breakdown
242-40W8-XYZ*
VHF
UHF
136-162 MHz
Dual IF 12.5 & 25 kHz
136-162 MHz
Dual IF 6.25 & 12.5 kHz
148-174 MHz
Dual IF 12.5 & 25 kHz
148-174 MHz
Dual IF 6.25 & 12.5 kHz
406.1-440 MHz (for U.S.)
Dual IF 12.5 & 25 kHz
406.1-440 MHz (for U.S.)
Dual IF 6.25 & 12.5 kHz
440-476 MHz (for U.S.)
Dual IF 12.5 & 25 kHz
440-476 MHz (for U.S.)
Dual IF 6.25 & 12.5 kHz
406.1-430 MHz (for Canada)
Dual IF 12.5 & 25 kHz
406.1-430 MHz (for Canada)
Dual IF 6.25 & 12.5 kHz
450-470 MHz (for Canada)
Dual IF 12.5 & 25 kHz
450-470 MHz (for Canada)
Dual IF 6.25 & 12.5 kHz
*An F should follow any part number to designate an Integra-TR with the cooling fan option.
Page | 10
Page | 11
1.6.1 TRANSCEIVER IDENTIFICATION
The transceiver identification is a random, unique serial number (SN) that can be found on the side label of the
Integra-TR device. It is also printed on the box label.
1.7
ACCESSORIES AND OPTIONS
Table 5 - Accessories
Part Number
Accessory
250-4008-001
697-5000-101
Integra-TR Field Programming Kit includes software, technical manual on CD ROM with
programming cable (Part Number 697-4008-408)
SMA to Type N-Male Adapter Cable
002-4008-100
Start-Up Disc includes Field Programming Software, Manual and Quick Start Guide
Catalog Number + (F)
Factory Installed Cooling Fan
697-4008-001
Power cable
250-0300-133
Switching Power Converter (SPC)
250-0300-175
Demo Power Kit
250-0045-103
Data Interface Kit
250-0005-105
Data Diagnostic Kit
250-5800-408
Integra-TR DIN-rail Mounting Kit
Contact Technical Service
*Full-duplex base station
Figure 6: Integra-TR Mechanical Specifications
Page | 12
1.8
SPECIFICATIONS
These specifications are subject to change without notice. RF specifications are measured per TIA/EIA-603 with a
psophometric baseband filter.
General
Frequency
Channels
Channel Bandwidth
Operating Temperature
Supply Voltage
RX Current Drain at 13.3 VDC
TX Current Drain at 13.3 VDC
Power Saving Mode Current Drain
Cold Start
Warm Start Rx
Warm Start Tx
Tx Turn On Time
RX/TX Bandwidth (without tuning)
VHF 136-174 Dual IF, UHF 406.1-476 MHz Dual IF
Multi-channel capability under system PLC control
VHF - 6.25 and 12.5 kHz or 12.5 and 25 kHz (software programmable)
UHF - 12.5 and 25 kHz (software programmable)
-30° to + 60° C
10 - 16 VDC maximum (nominal 13.3) Fuse protected against reverse voltage
3Aconnected
fuse: not field
replaceable)
<(internal
270 mAsurface
(with amount
terminal
to Integra-TR
COM port)
<2.6 A
<20 mA
4 sec (typical)
45 to 60 ms (depending on radio model and temperature)
55 to 70 ms (depending on radio model and temperature)
15 ms (typical)
38 MHz 136-174 (Dual), 34 MHz (406.1-440 Dual)
36 MHz (440-476 Dual)
Includes 102 cm power cable
Receiver
Sensitivity
Alternate Channel Selectivity (6.25 kHz)
Adjacent Channel Selectivity (12.5 kHz)
Adjacent Channel Selectivity (12.5 kHz)
Adjacent Channel Selectivity (25 kHz)
Intermodulation
Spurious Rejection
Conducted Spurious
0.35 µV for 12 dB SINAD
>65 dB minimum
>60 dB minimum x51 - Dual IF 6.25 & 12.5 kHz models
>55 dB minimum x50 - Dual IF 12.5 & 25.0 kHz models
>65 dB minimum
>70 dB minimum
>70 dB minimum
< -57 dBm
Cold Start: Time from DC power applied until unit is fully ready to receive or transmit data
Warm Start Rx: In power saving modes (sleep or suspend), wake-up time for full receiver recovery
Warm Start Tx: In power saving modes (sleep or suspend), wake-up time for full transceiver operation
Tx Turn On Time: Typical Rx to Tx switching time for stable transmission
Transmitter
RF Power Output
1 to 5 Watts, software adjustable
Spurious and Harmonics
<-57 dBc (-20 dBm)
Frequency Tolerance
+ 1.5 PPM
Tx Duty Cycle
50%, max. Tx time 30 seconds, extended Tx time with the cooling fan option
Page | 13
Modem/Logic
Operation
Simplex/half duplex
Data Bit Rates (b/s)
25 kHz: 4800/9600/19200; 12.5 kHz: 4800/9600
Modulation Type
DRCMSK (Differential Raise-Cosine Minimum Shift Keying)
RTS/CTS Delay (RTS mode)
4 ms
Addressing
10 bit station address, 1 bit station type (master / remote)
12.5 kHz @ 9.6 kbps: -104 dBm, 1x10-6 @ 1.4 µV
25 kHz @ 4.8 or 9.6 kbps: -107 dBm, 1x10-6 @ 1.0 µV
25 kHz @ 19.2 kbps: -100 dBm, 1x10-6 @ 2.3 µV
Bit Error Rate (BER)
COM Port
Interface
Data Rate
Protocol
Transmit Control
EIA RS-232C
1200 - 19200 b/s
Transparent, 7 or 8 data bits, 1 or 2 stop bits, even, odd or no parity
RTS or DOX (data operated transmit)
Set Up Port
Data Format
Proprietary binary for setup, ASCII for diagnostics
Data Rate
9600 b/s, 8 bit, no parity, 1 stop bit
Analog Inputs
Two inputs, 0-10 VDC, 8 bits. May be read only via Offline Diagnostics.
Absolute maximum input voltage < 20 Vdc. Inputs are reverse-voltage protected.
Interface
Digital Outputs
Interface
Two outputs, requires external pull-up to 2 to 10 Vdc. Set via Offline Diagnostics
Display
4 Bi-color status LEDs
RUN/PWR/ CS/SYN, RX/TX, RD/TD
Connectors
RF
SMA Female
COM
DE-9F
SETUP/DIAG
DE-9F
Power - I/O
Snap & Lock 4-Pin DC Power Jack
Diagnostics
Online
Short ID, temp, B+ voltage, local RSSI, remote RSSI, fwd and rev power, Rx Quality
Offline
Online plus: Demodulated Signal Voltage, Analog Input Levels, Digital Outputs
Approvals/Certifications
VHF
FCC IDENTIFIER
NP44018450
IC
773B-4018450 3K20F1D, 4K00F1D, 5K67F1D, 8K08F1D, 9K30F1D, 16K3F1D
IDENTIFIER
3K20F1D, 4K00F1D, 5K67F1D, 8K08F1D, 9K30F1D, 16K3F1D
Page | 14
Approvals/Certifications
UHF
FCC IDENTIFIER
NP44048350
IC
773B-4048350 9K30F1D, 15K3F1D
IDENTIFIER
9K30F1D, 15K3F1D
FCC IDENTIFIER
NP44048351
3K30F1D, 3K40F1D, 8K80F1D
FCC IDENTIFIER
NP44048551
3K30F1D, 3K40F1D, 8K80F1D
IC
IDENTIFIER
773B-4048351 3K30F1D, 3K40F1D, 8K80F1D
IC
IDENTIFIER
773B-4048551 3K30F1D, 3K40F1D, 8K80F1D
GETTING STARTED
It is easy to set up an Integra-TR network to verify basic unit operation and experiment with network designs and
configurations. An RX/TX antenna is required for basic operation. It is important to use attenuation between all demo units
to reduce the amount of signal strength in the test environment.
2.1
DEVICE CONNECTIONS
Refer to the diagram below for the proper device connections for basic operation.
2.2
FIELD PROGRAMMING SOFTWARE
The Integra-TR Field Programming Software (FPS) is the programming and diagnostics software for the Integra-TR wireless
modem. The software allows the user to edit and program user programmable settings, interactively tune modem and RF
parameters, and monitor diagnostic data from the Integra-TR.
There are two specific model categories. The 2424048X50 models are the 12.5/25.0 kHz models and the 2424048X51 are
the 12.5/6.25 kHz models. The models are set up at the factory. The model specific parameters are grayed out in the Field
Programming Software and cannot be changed outside of the factory.
Page | 15
Integra-TR FPS is available on the Start-Up CD-ROM as a .zip file. You may also visit the Download Library available from the
Support Menu at www.calamp.com for the most current version available. The Field Programming Software for the
Integra is the professional service installer interface. The Field Programming Software should never be made
available to unqualified personnel.
2.2.1 INSTALLING THE FPS
To use the software, you will need a PC with Windows 98 or later and at least one operational COM Port available.
STEP 1 Open the .zip file and double-click on the setup.exe application. After the application is extracted from the .zip
file, you will be brought to the Integra-TR Setup screen. Click OK to begin.
STEP 2 Click the image of the PC to install the software.
STEP 3 The program will then be added to the folder name shown in the Program Group box, the default is Dataradio
Utils. Click Continue to finish the install.
Page | 16
2.2.2 USING THE FPS
Make sure all connections are made as shown in the diagram and then power on the device.
STEP 1 Locate the Dataradio Utils folder (or if you named the Program Group box differently during install) and select the
IntegraTR application.
STEP 2
From the Integra-TR Programmer screen, click on the Program button in the upper left corner. This will bring up the
Program Parameters screen and display the option to automatically configure the device as a Remote or Master.
Click OK.
Page | 17
STEP 3 Click the Parms button in the upper left corner of the FPS screen. Here the Modem, Com/Analog, Radio and
Frequencies settings can be changed. Click OK when done.
Your modem is now ready for use.
NETWORK APPLICATIONS
Integra-TR is suited to a variety of network applications. Its primary design goal was to satisfy the needs of SCADA systems
using RTUs or PLCs in either point-to-point or point-to-multipoint service. Below is an overview of common configurations.
3.1
RF PATH AND COMMUNICATIONS RANGE
Integra-TR is designed for use over distances up to 30 miles + (50 km) depending on terrain and antenna system. To assure
reliable communications, the RF (radio frequency) path between stations should be studied by a competent professional
who can determine what antennas are required and whether or not a repeater is needed.
3.2
COMMON ARCHITECURAL CHARACTERISTICS
The networks described in this section share common characteristics:
1.
2.
The DTE (data terminal equipment) network speed (1200, 2400, 4800, 9600 and 19,200 b/s) must be the same for all
stations in a network.
Transmission of online diagnostics may be enabled or disabled at any station or stations without affecting their ability
to communicate with other stations.
3.2.1 POINT-TO-POINT SYSTEM
A simple point-to-point connection is shown in Figure 7. In this system, the user's equipment (DTE) may be set up in either a
peer-to-peer or a Master-Remote configuration.
Page | 18
Figure 7 - Point-to-Point System
3.2.2 POINT-TO-MULTIPOINT SYSTEM
A basic point-to-multipoint system is shown in Figure XX.
Figure 8 - Point-to-Multipoint System (simplex or half-duplex)
If a half-duplex radio network is used (i.e. two frequencies with the master station transmitting and receiving on the reverse
pair from the remotes), the master station can be either full duplex or half-duplex.
If a simplex radio network is used (i.e. a single frequency for all stations), we recommend that the master Integra-TR be set
to “master”, the remotes to “remote” and all units to “selective” data delivery. This will prevent remote stations from
hearing each other's responses. For full duplex configuration, set the receiving unit Rx/Tx Mode to Rx Only (using the Field
Programming Software). Set the transmitting unit mode to Tx Only.
Figure 9 - Point-to-Multipoint System (full-duplex)
Page | 19
Figure 10 - Point-to-Multipoint System (full-duplex repeater)
Page | 20
3.2.3 EXTENDING A LANDLINE (TAIL CIRCUIT)
Integra-TR may be used to extend a landline circuit (giving access to difficult locations, etc.).
This type of connection is called a “tail circuit” and is shown in Figure 11. The tail circuit assembly may be used in any of the
network types described in the preceding sections.
Figure 11 - Landline (Tail Circuit)
Note: The line modems should be full-duplex units.
Figure 12 - DCE Crossover Cable for RTS-CTS Mode
Some point-to-point FDX landline modems or line drivers may require the use of DOX mode and an alternate pinout for
DTR, DCD, CTS and RTS as shown in Figure 13.
Figure 13 - DCE Crossover Cable for DOX Mode
Page | 21
4
INTEGRA-TR FIELD PROGRAMMING SOFTWARE
The Integra-TR Field Programming Software is the programming and diagnostics software for the Integra-TR wireless
modem. The Field Programming Software allows the user to edit and program user programmable settings, interactively
tune modem and RF parameters, and monitor diagnostic data from the Integra-TR.
Integra Field Programming Software is available on the Start-Up Disc shipped with this device. You may also visit the
Download Library available from the Support Menu at www.calamp.com for the most current FPS Version available.
To use the FPS, you will need a PC with Windows 98 or later and at least one operational COM Port available.
4.1
INTEGRA-TR PROGRAMMER WINDOW
Firmware updates:
The Integra-TR firmware resides in flash EPROM and is designed to allow field updates. Updates are done using a PC
connected to the Integra-TR but do not require opening the unit. Updates should be coordinated by the Technical Service
team.
4.2
FILE MENU
From the primary Programmer screen, the File Menu offers the following options:

Open Data File
Page | 22



Save Data File
Save Data File As
Open Integra Data File
Figure 14: Integra-TR Programmer – File Menu
4.3
EDIT MENU
From the primary Programmer screen, the Edit Menu offers the following options:








Setup Modem/Radio Parameters
Version Request
List Information
Apply Integra Reset
Program/Comment ID
Program Parameters
Read Parameters
Copy Parameters
Figure 15: Integra-TR Programmer – Edit Menu
Page | 23
4.3.1 SETUP MODEM/RADIO PARAMETERS
To access the Setup Modem/Radio Parameters screen, use the Parms Icon. You may also access this screen from the Edit
menu.
Setup Modem/Radio Parameters allows the user to view and edit Integra-TR’s programmable parameters. Programming
parameters can be stored in a data file with the .DAT file extension. Programmable parameters are used by the
Read/Program Parameters screen for programming into nonvolatile memory (see This section describes the Modem
Operating Parameters shown in Figure 15.
Figure 16).
Parameter settings are modified from four screen tabs: the Modem tab, Com/Analog tab, Radio tab and Frequencies tab.
Once the desired parameters have been entered for each window, select OK to store the parameter information into local
PC memory or select Cancel to exit the Set up screen without making any modifications to the currently stored parameter
file.
4.3.1.1 SET UP MODEM/RADIO PARAMETERS: MODEM TAB
This section describes the Modem Operating Parameters shown in Figure 15.
Figure 16: Setup Modem/Radio Parameters – Modem Tab

Modem Type
Displays the Modem type of the connected device

Board Rev
Displays the hardware revision number of the modem board in the connected device
Page | 24


Short ID
Enter a Short ID number that will be used to identify an individual device within the network. Short IDs may range
from 1 to 254 or from 256 to 1023. Short ID 255 is reserved. Note: Firmware versions 2.10 and earlier only allow
short IDs of 1-254.
Serial No.
Displays the serial number for the modem board of the connected device.

Comment
Integra-TR Field Programming Software supplies this field for user-convenient description(s): customer name,
location. technical info...). Comments can be text up to 24 characters in length, including spaces.

Compatibility
Select Integra-TR or Integra-T to configure the compatibility mode for use with previous Integra models.
Integra-TR - used for networks made up of Integra-TR wireless modems.
Integra-T/TR - used for “on-air” backward compatibility with the Integra-T for bit rates of 4800 and 9600 b/s
(full channel units only). The Integra-TR is capable of selectable network speeds of 4800 and 9600 b/s for halfchannel units (12.5 kHz) or 4800, 9600, 19200 b/s for full-channel units (25 kHz). Use the Integra-TR mode
whenever feasible.

Sleep Mode
Select Enabled/Disabled. When enabled, the unit is in low power consumption (approximately 15 mA). In Sleep
Mode, the Integra-TR cannot detect the presence of a carrier. Only asserting RTS on the COM or Setup ports will
wake the unit. It is ready to receive and decode data within 45 to 65 mS (dependent on Integra model and
temperature) after wake-up.

Data Delivery
Select All/Selective. This field determines if data should be delivered to the COM port. Designating a unit as
Master or Remote sets a flag in the header identifying the Unit Type of the originating station:
o All - this option causes the unit to accept (on the receive side) all data transmissions.
o Selective - this option causes the unit to accept (on the receive side) data only if it originates from a unit
of the opposite Unit Type (i.e., a Master will only accept data from a Remote and a Remote will only
accept data from a Master).

Network Speed
Select the bit rate of the RF link between units. This can be different from the COM Port baud rate. This setting
must be the same for all units in the network.
o 4800 b/s - selectable for, half- and full-channel models and for full-channel models.
o 9600 b/s - selectable for half- and full-channel models and for full-channel models.
o 19200 b/s - selectable for full-channel models only.

Tx Online Diags
Check box to enable Online Diagnostics; Refer to Section XX for more information on Diagnostics and their effect
on the radio network

Unit Type
Radio button selection for Master or Remote configuration
Page | 25

Station ID (CWID)
Enter the Station ID (CWID) or FCC Call Sign for the system. It is sent out as Morse Code at predetermined intervals.
Station ID is a combination of letters (upper-case) and numbers (0 - 9) up to 9 characters in length.

CWID Interval
CWID Interval is used to set the interval of time the unit will transmit the Station ID (CWID) or FCC Call Sign. The
range is 1 to 255 minutes in 1 minute intervals, with 0 being disabled. To enable the transmissions of the Station ID
(CWID) or FCC Call Sign, a non-zero value must be set for the CWID Interval. Only one unit in a system should be
programmed to transmit the Station ID (CWID), typically the Master.

Extended Preamble
This field extends transmitted synchronization time when the unit is used in a network with repeaters. The default
is 5 mS and the range is 0 to 100 mS in 5 mS intervals. Add 10 mS for each Repeater an Integra-TR communicates
through in a network (dependent on user’s protocol). Note: Units supplied or updated prior to November of 2001
use a default value of 0 mS for Extended Preamble. Extensive testing has shown 5 mS to be the most robust
setting. If timing is critical in your application, this value can be set back to 0 mS.

Suspend Period
Set the length of time the Integra-TR goes to cycled lower power mode. The range for Suspend Period is from 50 to
12,000 mS in 50 mS intervals. Setting this range to a value of 0 disables Suspend Period.

Activity Timeout
Activity Timeout is used to set the minimum length of time the unit will remain awake in the presence of a carrier range is 1 to 255 seconds in 1 second intervals. This field is active only if Suspend Period is enabled. A non-zero
value must be set to enable Suspend Period. The same Activity Timeout and Suspend Period values must be set for
both Master and Remote units. See
Figure 17 for a Suspend Mode Timing graphic.
Figure 17: Suspend Mode Timing
Page | 26
4.3.1.2 SET UP MODEM/RADIO PARAMETERS: COM/ANALOG TAB
The COM/Analog tab allows user programming of various COM Port and External input/output parameters (see Figure 18).
Figure 18: COM/Analog Setup Parameters Screen
4.3.1.2.1

COMMUNICATION PARAMETERS
Tx Control
This radio button selects the unit’s mode at the beginning of a transmission
o RTS – Request to Send
o DOX – Data Operated Transmit
The Transmit Control default mode is DOX in which the unit begins a transmission as soon as data is presented to the COM
Port. The optional mode is RTS in which the unit begins transmission only when the RS-232 RTS input pin of the COM Port is
raised and continues transmitting until the RTS is dropped. Selecting RTS also activates the switched option in DCD control.
Figure 19: Integra-TR Control Signal Timing
Page | 27

DCD Control
Radio button selection for RS-232 DCD (Data Carrier Detect) mode
Active – DCD is always asserted
Switched – follows the radio carrier and data sent to DTE

DTE Baud Rate
Select 1200/2400/4800/9600/19200 to configure the port speed of the COM Port

DTE Data Format
User Selectable; Default = 8 bits, no parity, 1 stop. Other options include:
8 bits, no parity, 2 stop
8 bits, odd parity, 1 stop
8 bits, odd parity, 2 stop
8 bits, even parity, 1 stop
8 bits, even parity, 2 stop
7 bits, no parity, 1 stop
7 bits, no parity, 2 stop
7 bits, odd parity, 1 stop
7 bits, odd parity, 2 stop
7 bits, even parity, 1 stop
7 bits, even parity, 2 stop

Data Fwd Timer
User Selectable to set the timing between data blocks in a transmission to accommodate some RTU’s special
timing requirements:
Normal = 15 ms (default)
Fast = 5 ms (do not use for baud rates below 2400 b/s)

Break
Select the device response to break signals (protocol dependent) on the COM Port:
Ignore break - unit does not transmit or receive break signals
Transmit break - unit transmits and receives break signals

Deferred Rx-Data Delivery
This field sets the period of time the unit waits until delivering received data to the COM Port. Range is 0 to 255 ms
in 1 ms intervals (keeps delays minimum for protocols susceptible to inter-character delays).
4.3.1.2.2
EXTERNAL I/O PARAMETERS
Page | 28
4.3.1.2.2.1
EXTERNAL I/O 1 (GREEN)
These radio buttons select configuration of Pin 3 on the Power - I/O Connector (green wire):

Analog Input
An option on units not equipped with the cooling fan option - can be used to monitor an external voltage (0 to 10
volts). Monitoring is from the Offline Diagnostics screen

Tx Controlled Fan
Selecting this option will cause the unit to turn the fan ON at the start of a transmission and OFF after a
predetermined timeout (TX Controlled Fan Timeout) at the completion of a transmission. The length of time the
fan is on is the length of the transmission plus the timeout time. This option is displayed for versions of firmware
that support fan control output based on transmissions (Ver 2.04 and later).

Digital Output
An option for units not equipped with the cooling fan option. This connection can be used to control the opencollector transistor on the connector. The open-collector output can sink a maximum current of 100 mA when the
modem board rev is 0 or 1. The output is controlled from the Offline Diagnostics screen. Error! Reference source
ot found. shows the Field Programming Software interface for Digital I/O.

Channel Select 1
For use with models NOT equipped with the cooling option. This setting will configure the connection to be an
analog input for 2 or 4 Channel Select Mode. If Channel Select 2 is NOT selected, this input and Channel Select 2
input selects between Channels 1, 2, 3 and 4. A low level (logic 0) is a voltage less than the Channel Select Voltage
and a high level (logic 1) is a voltage greater than the Channel Select Voltage. The Channel Select Voltage is
selected on the Radio Tab. For 2 Channel Select Mode, see Table 6 "4 Channel Select Mode". If configured as a
Digital Output, the open-collector transistor requires an external pull-up (i.e., resistor) to a voltage of 2 to 10 volts.

Tx Controlled Fan Timeout
Used to set the interval of time the unit will keep the fan turned ON after a transmission is completed. The range is
5 to 255 seconds in 1 second intervals.
4.3.1.2.2.2
EXTERNAL I/O 2 (WHITE)
These radio buttons select configuration of Pin 4 of the Power - I/O Connector (white wire):

Analog Input
For use on units not equipped with the cooling option - can be used to monitor an external voltage (0 to 10 volts)

Rx TP Output
Performs as the demodulated signal level test point. The Rx TP level is half of the internal Rx Test Point

Ant. SW Control
Supports the use of a redundant base station. Ant. SW Control configuration is dependent on hardware
configuration and should not be changed in the field
Page | 29

Digital Output
This connection can be used to control the open-collector transistor on the connector. The open-collector output
can sink a maximum current of 40 mA when the modem board rev is 0 and 100 mA when the modem board rev is
1. The output is controlled from the Offline Diagnostics screen NOTE: When configured as a Digital Output, the
open-collector transistor requires an external pull-up (i.e., resistor) to a voltage of 2 to 10 volts. Note: When
configured as a Digital Output, the open collector transistor requires an external pull-up (i.e., resistor) to a voltage
of 2 to 10 volts.

Channel Select 2
Select to configure the connection to be an analog input for 2 or 4 Channel Select Mode. If Channel Select 1 IS NOT
selected, this input selects between Channels 1 and 2. If Channel Select 1 IS selected, this input and Channel Select
2 input selects between Channels 1,2,3 and 4. A low level input and Channel Select 2 input selects between
channels 1,2,3 and 4. A low level (logic 0) is a voltage less than the Channel Select Voltage and a high level (logic 1)
is a voltage greater than the Channel Select Voltage. Channel Select Voltage is selected on the Radio Tab. For 2
Channel Select Mode, a low level input will select channel 1 and a high level will select Channel 2. For 4 Channel
Select Mode, see Table 6.
Table 6 - 4 Channel Select Mode
4.3.1.3
Channel Select 2
Channel Select 1
Channel 1
low
low
Channel 2
low
high
Channel 3
high
low
Channel 4
high
high
SET UP MODEM/RADIO PARAMETERS: RADIO TAB
The Radio tab allows user programming of various radio parameters.
Figure 20: Radio Setup Parameters Screen
Page | 30

Radio
Display the model of the connected radio device

Range
Displays the range number of the connected radio device

Channel Bandwidth
Displays the channel bandwidth of the connected device: Half-channel (12.5 kHz) or Full-channel (25 kHz)

Transceiver Type
Radio button selection for user configuration of transmit and receive characteristics of the device in accordance
with the type of network application:
Tx Only – For use in a full-duplex application to disable receptions on the unit used as the transmitter. Tx
Only designation pre-loads the synthesizer and allows faster attack time to speed up transmission
response.
Rx Only – For use in a full-duplex application to disable transmissions on the unit used as the receiver. Rx
Only designation prevents accidental transmissions.
Transceiver – For use in all other applications.

Disable Tx w/Carrier Present
Provides the following options to configure unit reaction to an RF carrier presence when a transmission is to begin:
Disabled - Select this option to instruct the unit to allow a transmission when a carrier is present.
Enabled (Discard data) - Select this option to instruct the unit not to allow a transmission if a carrier is
present. Any user data the unit receives on the COM Port while a carrier is present, is ignored and
discarded.
Enabled (Buffer data) - Select this option to instruct the unit not to allow a transmission if a carrier is
present. Any user data the unit receives on the COM Port while a carrier is present is buffered and sent
when the carrier is no longer present.

Carrier Sense
Denotes the RSSI level when the unit senses a carrier. Carrier Sense is used for data recovery, in the interpretation
of diagnostics, and to turn on the front panel CS LED. The threshold may be raised to prevent false Carrier Sense
operation in the presence of noise, inter-modulation, or other sources of interference (i.e. for ambient noise at 100 dBm, set the Carrier Sense for -95 dBm).

Tx Timeout
Used to set maximum period of time the unit will allow in a transmission. The range is 0 to 120 seconds in 1 second
intervals (0 being disabled). Tx Timeout is used to protect both the unit and the network in case a transmitter
becomes stuck on the air. For Integra-TRs equipped with the cooling option for extended transmit applications, the
Tx Timeout must be disabled. Warning: Disabling the timer may disrupt the network or damage the unit should it
become stuck in transmit due to excessive user data received on the COM port or the if the RTS signal remains
active.
Page | 31

Selected Channel
This field allows the user to choose a selected channel pair for receiving and transmitting. Allowable entries are 1
to 16. The selected channel will be used if Channel Select 1 and Channel Select 2 are NOT selected. (COM/Analog
Tab). Note: This feature is disabled when a Channel Select Line is enabled (green or white wire).

Chan Scan Time
Allows the user to configure the modem to switch (increment from the Selected Channel) to a new channel if it has
not received a valid data packet for this programmable time. This is programmable in steps of 20 seconds (60 to
5000 seconds, or 1 to 83 minutes). Setting Chan Scan Time to zero disables channel scan operation and the modem
remains on the selected channel. Note: This feature is disabled when Sleep/Suspend Period is enabled, when
Master Mode is enabled or when a Channel Select Line is enabled (green or white wire).

Chan Select Voltage
Allows the user to determine voltage thresholds for Channel Select 1 (green) and Channel Select 2 (white) inputs (if
programmed). A low level (logic 0) is a voltage less than the set voltage threshold and a high level (logic 1) is a
voltage greater than the set voltage threshold. Note: Multi-Channel operation is available in modem firmware
version 2.20 and later.
4.3.1.4 SET UP MODEM/RADIO PARAMETERS: FREQUENCIES TAB
The Frequencies Tab allows the user to program the radio channels (Frequency Pairs).
Figure 21: Frequencies Tab

Rx Frequency
Enter the Rx frequency of the designated receive channel

Tx Frequency
Enter the Tx frequency of the designated transmit channel. There are 12 VHF splinter channels available for
quarter-channel VHF (6.25 kHz) Integras.
Page | 32
The frequencies for these splinter channels are:
154.456250
154.463750
154.471250
154.478750
173.203750
173.237500
173.262500
173.287500
173.312500
173.337500
173.362500
173.396250

Tx Power
This field designates the channel pair Power Output Adjust value. The default value is 255 (5 watts). This value
should be left at the default value unless lower power is required to meet regulatory requirements, to increase the
allowable transmit duty cycle or to reduce transmit power. As the output is adjusted downward (less RF output
power) the overall current requirements of the Integra are lessened. When optimizing a system for operational
parameters such as RF coverage and over all power (current) usage, the correct amount of RF power needed for
coverage may actually be less than full (5 watts) output. This in turn can lower overall power (current) needs of the
wireless modem. NOTE: Power does not vary linearly with this parameter so some experimentation may be
required to determine the correct power setting.
4.3.2 VERSION REQUEST
From the Programmer Window, Select Edit – Version Reset to display the following information about the connected
device.





Integra-TR: displays the Modem Firmware Version Number)
Serial Number: displays the serial number of the modem module
Short ID: displays the Short ID of the connected device. Refer to Section XX to program the Short ID.
Comment: displays the comment field for the connected device. Refer to Section XX to enter a user comment.
Board Rev: Displays the board revision number of the connected device.
Figure 22: Version Request Screen
Page | 33
4.3.3 LIST INFORMATION
From the Programmer Window, Select Edit – List information to display the following information about the connected
device. The List Information Utility is a diagnostic tool for the modem’s firmware. This information will be required when
consulting with the Technical Support Department.
Figure 23: List Request Screen
4.3.4 APPLY INTEGRA RESET
From the Programmer Window, Select Edit – Apply Integra Reset to access the Reset Utility. Integra Reset tells the IntegraTR to perform a software reset. Select OK to perform station reset. The reset action performs the same function as cycling
power to the device.
Figure 24: Apply Integra Reset Screens
4.3.5 PROGRAM COMMENT/ID
From the Programmer Window, Select Edit – Program/Comment ID to access the Program Comment/ID configuration
screens. This utility is particularly useful if the Integra-TR being programmed was cloned from another unit (See Figure 25).
Page | 34
Figure 25: Program Comment/ID Screen

Short ID
Enter a number (from 1 to 254 and 256 to 1023 - 255 is reserved) used to identify an individual unit within the
network. You must click the Program Short ID button for changes to take effect.

Comment
Enter a short description that may be used to identify the device. Comments often include a name, a location,
technical information, or other user desired information. Comment fields must be in text format and are limited to
24 characters, including spaces. You must click the Program Comment button for changes to take effect.
4.3.6 PROGRAM PARAMETERS
From the Programmer Window, Select Edit – Program Parameters. Program Parameters allows the user to program the
currently loaded programmable parameters to the Integra-TR (the ID Number, Comment and Remote/Master settings are
extracted from the fields on the screen). This option can be used for programming the same Data File (.DAT) into multiple
modems (if .dat file is imported into the parameters field, the Short ID, Comment and Remote/Master settings will be
changed - verify correct ID, Comment and Remote/Master BEFORE clicking OK). At the completion of programming, the ID
Number will automatically be incremented.
Figure 26: Program Parameters
Page | 35
4.3.7 READ PARAMETERS
From the Programmer Window, Select Edit – Read Parameters. The Read Parameters function tells the Integra-TR to pull
the parameters that are currently programmed in the Integra-TR. To view these parameters, click the Parms Icon after
running the Read utility.
4.3.8 COPY PARAMETERS
From the Programmer Window, Select Edit – Copy Parameters. This allows the user to write the currently loaded
programmable parameters to the Integra-TR (including the ID Number, Comment and Remote/Master Settings).
4.4
UTILITIES MENU
From the primary Programmer screen, the Utilities Menu offers the following options:













Port Settings
Swap Com Ports
Port Statistics
Offline Link Test
Offline Diagnostics
Online Diagnostics
Diagnostic IDs and Alarms
User Test
Packet Test
Array Test
Ping Test
ASCII Terminal
Hex Terminal
Figure 27: Integra-TR Programmer – Utilities Menu
Page | 36
4.4.1 PORT SETTINGS
From the Programmer Window, Select Utilities – Port Settings
Integra-TR programming is done through the PC’s Primary COM Port. Primary and secondary COM ports are configured with
the Field Programming Software. The programming cable (included in the Programming Kit - DRL part number 250-4008001) is connected from the Setup Port on the Integra-TR to the PC’s COM port configured as the Primary Port. The Port
Settings screen of the Field Programming Software is accessed via the Utilities pull-down menu.
The Port Settings screens are used to configure the PC’s serial COM Ports. COM Port parameters are defined in 2.4.2.1.
COM Port assignments are displayed in the bottom status bar of the Integra-TR Field Programming Software screen.
Figure 28 – COM Port Settings Screen
4.4.1.1 PRIMARY/SECONDARY COM PORT PARAMETERS

COM Port
Select COM 1-32 to identify the Port number to be used for the Primary and Secondary COM ports

Baud Rate
Select 1200, 2400, 4800, 9600, 19200, 38400 or 115200 to set the communication speed for Primary and
Secondary COM Ports

Data Bits
Select 7 or 8 for the number of data bits transmitted or received for the Primary and Secondary COM Ports

Parity
Select Even, Odd, or None for the transmission or reception of any Parity Bits for the Primary and Secondary COM
Ports
Page | 37

Stop Bits
Select 1 or 2 for the number of Stop Bits transmitted or received for the Primary and Secondary COM Ports

DTR Enable
Select Yes/No. Enable to assert the DTR (Data Terminal Ready) line of the RS-232 Port when the port is open for
the Primary and Secondary COM Ports.

Mode
Select the communication mode to be used by the Integra-TR. Refer to Table XX for Communication Mode
descriptions.
Table 7 – Communication Mode Descriptions
Mode
Description
Sync/ESC with No HS
Sends data using Sync/byte-stuffing protocol without handshaking.
Sends buffered data without handshaking (this mode is required for
DOX operation.)
Sends data using the Sync/Esc byte-stuffing protocol with RTS/CTS
hardware handshaking.
Sends buffered data with RTS/CTS hardware handshaking.
Sends data using the Sync/Esc byte-stuffing protocol with flow control
handshaking.
Sends buffered data with flow control hardware handshaking.
Buffered with No HS
Sync/Esc with RTS/CTS HS
Buffered with RTS/CTS HS
Sync/Esc with Flow Control HS
Buffered with Flow Control HS

IP Address/Port Number
Selection of an IP Address and Port Number when IP Port is selected.. The Ethernet-to-RS-232 converter with this
IP Address must have a TCP (Telnet) server enabled. Allows the user to select the IP Port number used if the Port
Select has IP Port selected. This is the Port Number that will be used to make a TCP (Telnet) connection.

Port Select
Allows the user to choose data transmissions and receptions on a specified RS-232 COM port or an Ethernet
adapter via TCP (Telnet)
o Com Port – System data will be transmitted and received using the specified RS-232 COM port.
o IP Port – System data will be transmitted and received over the Ethernet to a specified IP address and
port number using the TCP (Telnet) protocol. Select this option if an Ethernet to RS232 converter is
implemented for the unit under test.
o OIP Port – This option should not be selected for Integra-TR models.
Page | 38
4.4.1.2 ADVANCED PORT SETTINGS
Figure 29 – Port Settings Advanced Tab

Ignore DCD Before Tx’ing
Allows the user to check for an inactive DCD before transmitting. If selected, no data is sent until DCD becomes
active

DCD Timeout
If Ignore DCD Before Tx’ing is selected, DCD Timeout determines the length of time to wait for DCD to become
inactive before data is sent. If the DCD does not become inactive during this time, the data is not sent.

SYNC Character
Allows the user to select the SYNC character when utilizing a Sync/Esc (Framing) Mode. The Sync Character is the
first character of a frame to be sent. This character is a HEX character.

ESC Character
Allows the user to select the ESC character when utilizing a Sync/Esc (Framing) Mode. The ESC Character precedes
any embedded SYNC or ESC characters that follow the initial SYNC character. This character is a HEX character.

CTS Timeout
Selects the RTS to CTS timeout when using an RTS/CTS hardware handshaking mode. This is the amount of time (in
50mS increments) the software will allow for the CTS line to become active after asserting the RTS line.

TCP/IP Response
Enter a time interval between 1.5 and 600 (seconds) to allow for the Unit to respond to Programming Commands
over a TCP/IP Connection. The value of this may require the use of the About Utility. By pinging the destination IP
Address, the utility will give back Minimum / Maximum / Average Times it takes to send and receive a packet over
the TCP/IP Connection. A safe value will be to use the Maximum Time (in seconds).
Page | 39

DMP Baud Rate
Select 1200, 2400, 4800, 9600, 19200, 38400 or 115200 to set the communication speed for Primary and
Secondary COM Ports when using the DMP Protocol. DMP is used to talk to the Integra modems through the Setup
Port.

SYNC/ESC Framing
A typical SYNC/ESC frame will look like the following character stream.
SYNC
ML
Data0
------
DataN Chksum
8 bits
8 bits
8 bits
------
8 bits
8 bits
And the following definitions are made:

SYNC (8 bits)
Marks the start of a frame when not preceded by and ESC character. When using a Sync/Esc (Framing) Mode, the
software will stuff this character automatically.

ML (8 bits)
The length of frame is given by ML. ML is the number of characters left to be received including the checksum but
excluding any ESC characters added as part of the protocol. When using a SYNC/ESC (Framing) Mode, the software
will stuff this character automatically (based on the number of data characters).

Data 0 - N (8 bits each)
Frame information.

Chksum (8 bits)
This is the 8 bit 2s complement of the sum of the frame less the SYNC character and any additional ESC characters
added (ignoring the carry out of the high order bits. When using a SYNC/ESC (Framing) Mode, the software will
stuff this character automatically.
4.4.2 SWAP COM PORTS
From the Programmer Window, Select Utilities – Swap Com Ports
This allows the user to swap the settings for the primary and secondary COM Ports. Since programming is done through the
Primary port, this is useful when programming multiple units. If a unit is connected to the Primary port, and another unit is
connected to the Secondary port, Swap COM Ports allows the second unit to be programmed without switching
programming cables. Swap COM Ports is also available from the Port Settings Primary and Secondary Port screens.
4.4.3 PORT STATISTICS
From the Programmer Window, Select Utilities – Port Statistics. This shows the current parameters of the PC’s primary and
secondary COM ports.
Page | 40
Figure 30: Port Statistics Screen

Baud Rate
Displays the current setting for the utilized COM port

RTS
RTS is an output from the user connected DTE device. This will be checked if active.

DTR
DTR is an output from the user connected DTE device. This will be checked if active.

CTS
CTS is an input to the user connected DTE device. This will be checked if active.

DSR
DSR is an input to the user connected DTE device. This will be checked if active.

DCD
DCD is an input to the user connected DTE device. This will be checked if active.

Bytes Tx’ed
Displays the number of bytes (characters) transmitted since the port was last opened.

Bytes Rx’ed
Shows the number of bytes (characters) received since the port was last opened.

Framing Errors
Shows the number of Framing Errors received since the port was last opened.
Page | 41
4.4.4 OFFLINE LINK TEST
From the Programmer Window, Select Utilities – Offline Link Test
The Offline Link Test is used to test the link between two units – the local unit connected to the PC and a remote unit.
Blocks of data are transmitted to the remote unit and the remote unit decodes and returns them. The transmitted and
received data blocks are compared and the ratio of the results is calculated. The Offline Link Test requires suspension of
user network operation.
Figure 31 - Offline Link Test Screen

Local ID
This is the Short ID of the unit connected to the computer.

Remote ID
Allows selection of the unit (by choosing its Remote ID) from which the Link Test information is gathered. Remote
IDs are set up in the Diagnostic IDs and Alarms Screen.

Clear
Allows the user to clear the display (blocks transmitted, responses received, blocks received and link quality).

Start
Used to begin the test.

Pause
Used to pause the test and allows the user to resume the test at a later time.
Page | 42

Save
Allows the user to save the current Offline Link Test results to a file.
The Offline Link Test returns the following statistics:

Blocks Tx’ed to Remote
Displays the number of data blocks transmitted to the remote unit.

Responses from Remote
Displays the number of responses heard from the remote unit.

Blocks Rx’ed from Remote
Displays the number of data blocks received from the remote unit.

Link Quality to Remote
Displays the receive quality of the remote unit; the number of correctly decoded transmissions received by the
remote divided by the number of total transmissions detected by the remote (in %).

Link Quality from Remote
Displays the ratio of data blocks received to data blocks transmitted (in %).

Overall Link Quality
Displays the overall link quality by combining the Link Quality to Remote ratio with the Link Quality from Remote
ratio (in %).

# of Blocks to Send
Allows the user to determine the number of blocks to send before stopping (with 0 being disabled).

Block Delay (s)
Allows the user to determine the delay between the transmission of data blocks in 0.25 second intervals (0.00 to
10.00 seconds).
4.4.5 OFFLINE DIAGNOSTICS
From the Programmer Window, Select Utilities – Offline Diagnostics for user access to the Get Diags request. An Offline
Diagnostics request requires suspension of user network operation.
Page | 43
Figure 32: Offline Diagnostics Screen
Offline Diagnostic parameters include the following:

Unit ID
The Short ID of the unit sending diagnostics.

RSSI Level
Received Signal Strength Indication in dBm.

Battery Voltage
Supply voltage

Temperature
Internal case temperature in Celsius.

Forward Power
Forward power in watts or dBm.

Reverse Power
Reverse power in watts or dBm.

Preamble Good
The number of correctly decoded transmissions received in the last 15. Used with Preamble Total, this serves as an
indication of how well the unit is receiving data.

Preamble Total
The number of total transmissions detected, maximum is 15. Used with Preamble Good, this serves as an
indication of how well the unit is receiving data.
Page | 44

XCVR Status
Displays the status of the transceiver.

Tx Timeout
A request for a remote unit to transmit causes the unti to transmit on the programmed transmit frequency until
the Tx Timeout Timer expires. Program the Tx Timeout Timer in the Setup Modem/Radio Parameters/Radio Tab.

Progress
The Progress panel shows the progress of the Get Diags request.

Tx Mode
Allows the user to select different transmit modes when the unit is told to transmit:
o Tone: the unit will transmit a 1200 Hz tone.
o Mod Balance: the unit will transmit a 100 Hz square wave.
o Random Data: the unit will transmit random data.
o No Modulation: the unit will transmit with no modulation.

External I/O 1 (Pin 3 - Green Wire):
When the I/O 1 connection of the Power - I/O Connector is configured as a Digital Output, External I/O displays the
state of the open-collector transistor (ON-Grounded/OFF-Open). If configured as an Analog Input, External I/O
displays the voltage on the connector (in volts). Programming of External I/O 1 is performed in the Setup
Modem/Radio Parameters screen.

External I/O 2 (Pin 4 - White Wire):
When the I/O 2 connection of the Power - I/O Connector is configured as a Digital Output, this displays the state of
the open-collector transistor (ON - Grounded / OFF - Open). If configured as Analog Input, External I/O 2 displays
the voltage on the connector (in volts). Programming of the External I/O 2 is performed in the Setup Modem/Radio
Parameters screen.

External I/O 1 ON (Grounded):
When the I/O 1 connection of the Power - I/O Connector is configured as a Digital Output, this checkbox is enabled
to allow for the change of state of the open-collector output of Pin 3. Clicking on this check box causes immediate
action to change the state of the output. This is true for local or a selected remote ID.

External I/O 2 ON (Grounded):
When the I/O 2 connection of the Power - I/O Connector is configured as a Digital Output, this checkbox is enabled
to allow for the change of state of the open-collector output on Pin 4. Clicking on this check box causes immediate
action to change the state of the output. This is true for local or a selected remote ID.
Modem Select

Local ID
Allows the user to send commands to the local unit (the unit interfaced to the computer). The Short ID for this unit
is shown.
Page | 45

Remote ID
Allows the user to send diagnostic commands to any specific remote unit and obtain its diagnostic information.
The Remote ID is selected from the list of Remote IDs set up in the Diagnostic IDs and Alarms screen.
Diagnostic Select

Selected Remote ID
This button allows the user to gather Offline Diagnostics from the selected Remote ID only.

Remote ID List
This button allows the user to gather Offline Diagnostics from all the IDs in the list of Remote IDs (including the
local unit).

Get Diags
Allows the user to send the command for Offline Diagnostics. The command is sent to the unit connected to the
computer if the Local ID button is selected. The command is sent to the selected Remote ID if the Remote ID and
Selected Remote ID buttons are selected. The command is sent to the list of Remote IDs if the Remote ID and
Remote ID List buttons are selected.

Stop
Allows the user to stop any commands for Offline Diagnostics from being sent.

Save
Allows the user to save the current Offline Diagnostics to a text file.

RSSI/Pwr
Shows the current RSSI level (in dBm) while the local unit is receiving and the current Power Level (in watts or
dBm) while the local unit is transmitting.

Rev Pwr
Allows the user to view the reverse power instead of forward power while the local unit is transmitting.

F5
Pressing the F5 key will cause the unit to transmit on the programmed transmit frequency.

F6
Pressing the F6 key will cause the unit to go to receive on the programmed receive frequency.
Note: Commanding a remote unit to transmit will cause the unit to transmit on the programmed transmit frequency until
the Tx Timeout Timer expires. Be sure to program the Tx Timeout Timer in the Setup Modem/Radio Parameters Screen
4.4.6 ONLINE DIAGNOSTICS
From the Programmer Window, Select Utilities – Online Diagnostics. Online Diagnostics are transmitted by each unit in a
network before the user’s data is transmitted. All units must be programmed with the Online Diagnostics parameter found
on the Setup Modem/Radio Parameters screen to receive Diagnostics from a system. The unit that the computer is
Page | 46
interfaced with will output Online Diagnostics as they are received. Using Online Diagnostics does not require suspension of
network operation.
Online Diagnostics are subject to alarm conditions defined in Section XXX Diagnostic IDs and Alarms. When Online
Diagnostics are received and a diagnostic field falls outside the alarm limits, value X will be designated as less than < or
greater than > the allowed parameters.
Figure 33: Online Diagnostics
The following Online Diagnostics are gathered:

Short ID
Displays the Short ID of the unit transmitting the diagnostics.

Temp
Displays the internal case temperature (in Celsius) of the unit transmitting the diagnostics.

Batt
Displays the supply voltage (in volts) of the unit transmitting the diagnostics.

Local RSSI
If these are the diagnostics from a Remote Station, Local RSSI indicates the RSSI level of the Local Station obtained
by the Remote Station transmitting these diagnostics. If these are the diagnostics from the Local Station, Local RSSI
indicates the RSSI level of the Local Station from the last transmission of a Remote Station.

FwdP
Displays the forward power (in watts) of the unit transmitting the diagnostics.
Page | 47

RevP
Reverse Power displays the approximate measure of reverse (reflected) power of the unit transmitting the
diagnostics. This is represented as “Good” if the reverse power is within acceptable limits and is represented as
“Bad” if the reverse power is too high. The threshold is set to approximately 1/4 the forward power.

Remote RSSI
If these are the diagnostics from a Remote Station, Remote RSSI indicates the RSSI level of the Remote Station
from the last received transmission. If these are diagnostics from the Local Station, Remote RSSI indicates the RSSI
level of the Remote Station last received at the local Station.

Rx Quality
Displays the receive quality (in %) of the remote unit. This is the number of correctly decoded transmissions
received (in the last 15) divided by the number of total transmissions detected.

Time
The time stamp when the diagnostics were received.

Filter
Allows the user to filter Short IDs. The following options are available:
Off (All IDs): no IDs are filtered out.
ID List: only the IDs in the Filter ID List are shown.
Selected ID: only the selected ID in the Filter ID List is shown.

Display
Allows the user to format on screen data. The following options are available:
Scroll (by time): displays the diagnostics as they are received.
Slotted (by ID): sorts the diagnostics by Short ID. Using this option, each Short ID will have one row of
diagnostics, showing the most recent.

Progress
This panel shows the sorting progress of the diagnostics if a filter was changed.

Local ID
The Short ID of the unit interfaced with the PC.

Filter ID List
This is a listing of Remote IDs setup in the Diagnostic IDs and Alarms Screen. This list is used for selecting a filter.

Pause
Allows the user to pause the reception of the diagnostics for scrolling through the grid.

Clear
Allows the user to clear the display and current Online Diagnostics.

Save
Allows the user to save the current Online Diagnostics to a file. A maximum of 4096 lines of data can be saved.
Page | 48
4.4.7 DIAGNOSTIC IDS AND ALARMS
From the Programmer Window, Select Utilities – Diagnostics IDs and Alarms
The Diagnostics IDs and Alarms screen allows the user to set up the ID List for use with the Offline Link Test, and Offline and
Online Diagnostics as well as Alarms for use with Online Diagnostics.
Figure 34: Diagnostic IDs and Alarms Screen
4.4.7.1 ID ENTRY AND LIST

ID Entry
Allows the user to add Short IDs to the ID List. The range of this field is 1 to 1023 (ID 255 is reserved). A Short ID is
added to the ID list by hitting Enter or by pressing the Add ID button.

ID List
Allows the user to select a Short ID from the list to delete. A Short ID is deleted from the list by pressing the Delete
ID button.

IP Address
Allows the user to receive diagnostics through a serial to Ethernet converter with this IP Address. Default allows
the user to select a default unit for the diagnostics when received through a serial to Ethernet converter.
4.4.7.2 ALARMS FOR ONLINE DIAGNOSTICS
Alarm indications are available with Online Diagnostics. When Online Diagnostics are received and a diagnostic field falls
outside the Alarm limits, a “<“ character will designate a value less than the low Alarm and a “>” character will designate a
value greater than the High Alarm (See Figure 34).
Page | 49

Low/High RSSI
Enter the high and low limits for acceptable RSSI levels (in dBm).

Low/High Temp
Enter the high and low limits for acceptable temperature levels (in Celsius).

Low/High Batt
Enter the high and low limits for acceptable battery voltage levels (in volts).

Low/High Fwd Pwr
Enter the high and low limits for acceptable forward power levels (in watts).
4.4.8 USER TEST
From the Programmer Window, Select Utilities – User Test. The User Test utility is an Offline function and requires
suspension of network operation.
Figure 35: User Test Screen
A User Test’s diagnostic parameters include:

Unit ID
The Short ID of the unit from which the diagnostics were received

RSSI Level
Received Signal Strength Indication in dBm.

Battery Voltage
Supply voltage in volts.

Temperature
Internal temperature in Celsius.

Forward Power
Forward power in watts or dBm.
Page | 50

Reverse Power
Reverse power in watts or dBm.

External I/O 1
Voltage on the External I/O 1 Input from the Power - I/O Connector (in volts).

External I/O 2
Voltage on the External I/O Input from the Power - I/O Connector (in volts).

Preamble Good
The number of correctly decoded transmissions received in the last 15. Used with Preamble Total, this serves as an
indication of how well the unit is receiving data.

Preamble Total
The number of total transmissions detected, maximum is 15. Used with Preamble Good, this serves as an
indication of how well the unit is receiving data.

RSSI/Pwr
This panel shows the current RSSI level (in dBm) while the local unit is receiving and the current power level (in
watts or dBm) while the local unit is transmitting.

Rev Pwr
This check box changes forward power to reverse power on the Power Panel from while the local unit is
transmitting.

Power in dBm
This check box allows the user to view Fwd/Rev Power in dBm (instead of watts).

Tx Mode
This box allows the user to select different transmit modes when the unit is told to transmit.
Tone - the unit transmits a 1200 Hz tone
Mod Balance - the unit transmits a 100 Hz square wave
Random Data - the unit transmits random data
No Modulation - the unit transmits a carrier with no modulation

Rx/Tx Frequency
Shows the current transmit frequencies

F5
Pressing the F5 key will cause the unit to transmit on the programmed transmit frequency

F6
Pressing the F6 key will cause the unit to go to receive on the programmed receive frequency
Page | 51
4.4.9 PACKET TEST
From the Programmer Window, Select Utilities – Packet Test
The Packet Test allows the user to simulate a Host/Remote polling environment. The Host will send out a packet to the
Remote and the Remote will reply to the Master with the same packet information. This test is useful for testing the
modem link.
Figure 36: Packet Test Screen

Host Packets Tx’ed
Shows the number of data packet the Host device sent to the Remote

Remote Packets Rx’ed
Shows the number of data packets the Remote device successfully received from the Host

Host to Remote %
Shows the number of data packets the Remote device has successfully sent to the Remote

Remote Packets Tx’ed
Shows the number of data packets the Remote device sent back to the Host

Host Packets Rx’ed
Shows the number of data packets the Host device successfully received from the Remote

Remote to Host %
Shows the percentage of data packets the Remote device successfully sent to the Host
Page | 52

Overall %
Shows the percentage of Host received packets versus Host transmitted packets

# of Packets to Send
A programmable number to tell the Host how many data packets to send to the Remote. After the programmed
number of data packets are sent, the transmission will automatically stop

Bytes of Data/Packet
A programmable number to tell the Host the number of data bytes to send in each packet. The Remote will
respond with the same number of data bytes received

COM Port/ Network Radio
The ratio of COM Port baud rate to network (over-the-air) baud rate of the modem. This is used if the network
baud rate is slower than the COM Port baud rate. If the COM Port baud rate is 9600 and the network baud rate is
4800, set the ratio to 2. If the COM Port baud rate and the Network Baud Rate are the same, set the Ratio to 1

Packet Delay (s)
Tells the Host the number of seconds to delay between sending each data packet (range is from 0.00 to 10.00
seconds in 0.25 second intervals)

Host/Remote
Allows the user to choose the COM Port configuration
o Host (Primary Port) - Configure the Primary COM Port as the Host device (the device initiating packets to
the Remote device).
o Remote (Primary Port) - Configure the Primary COM Port as the Remote device (the device responding to
the packets from the Host device.
o Host/Remote (1 computer / 2 ports) - Configure the Primary COM Port as the Host device and the
Secondary COM Port as the Remote device. A computer with 2 COM Ports is required for this option.
o Host/Remote (1 Port using a Y-cable) - A computer with 1 COM Port is typical for this option (See Table 8).
Configure the Primary COM Port as the Host and Remote device. A Y-cable is required for this option
(where Tx connections are split out to the transmitting device and the Rx connections are split out to the
receiving device).
Table 8: Y-Cable Connections
Pin Name
DB-9
DB-25
Computer
Rx
Tx
DCD
RxD
TxD
DTR
20
GND
DSR
RTS
CTS
RI
22
Page | 53
4.4.10 ARRAY TEST
From the Programmer Window, Select Utilities – Array Test. The Array Test utility is used to send programmable length test
packets. The packets are built using one of four possible patterns. For pattern descriptions, refer to Section XX.
Figure 37: Array Test Screen

Packets Tx’ed
Shows the total number of data packets transmitted

# of Packets to Send
Shows the number of data packets to send before stopping (the range is 0 to unlimited)

Type of Data
Select the data pattern for each data packet. The size and format for each pattern is shown in the pattern
descriptions

Packet Size
Shows the number of data bytes in each packet

# of Packets
Shows the number of packets in each transmission

Packet Delay
Shows the amount of time (in seconds) to delay between each packet transmission (range is from
0.00 to 30.00 seconds in 0.25 second intervals).

COM Port
Select Primary or Secondary COM Port to be used for transmitting data.
Page | 54
4.4.10.1 PATTERN DESCRIPTIONS
ASCII Pattern
The ASCII Pattern Packet are 58 characters in length and have a sequence number at the beginning of each string, starting
at 000, incrementing to 999 and wrapping around to 000 again. The pattern used to build the packets should have the
following format (in ASCII):
000 ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
001 ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
--998 ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
999 ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
000 ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
001 ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ASCII Number Pattern
The ASCII Number Pattern are 54 characters in length and have a sequence number at the beginning of each
string, starting at 000, incrementing to 999 and wrapping around to 000 again. The pattern used to build the
packets should have the following format (in ASCII):
000 00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
001 00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
--998 00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
999 00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
000 00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
001 00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
Binary Pattern
Binary Pattern packets are 16 characters in length and have a sequence number every 16 characters, starting at
0x00, incrementing to 0xFF and wrapping around to 0x00 again. The pattern used to build the packets should have the
following format (in Hex):
00
01
02
-FE
FF
00
01
02
--
11
11
11
11
11
11
11
11
11
11
22
22
22
22
22
22
22
22
22
22
33
33
33
33
33
33
33
33
33
33
44
44
44
44
44
44
44
44
44
44
55
55
55
55
55
55
55
55
55
55
66
66
66
66
66
66
66
66
66
66
77
77
77
77
77
77
77
77
77
77
88
88
88
88
88
88
88
88
88
88
99
99
99
99
99
99
99
99
99
99
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
CC DD
CC DD
CC DD
CC DD
CC DD
CC DD
CC DD
CC DD
CC DD
CC DD
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
Page | 55
Random Binary Pattern
Random Binary Pattern is 16 characters in length and contains random binary data.
4.4.11 PING TEST
From the Programmer Window, Select Utilities – Ping Test. The PING Test is used to simulate a Host/Remote polling
environment. The Master sends out a packet to the Remote and the Remote replies to the Master with the same packet
information.
Figure 38: Ping Test

Remote
Displays the IP Address of the device under test

Minimum Time
Displays the minimum amount of time taken for the Ping Packet to echo back from the Remote device (in
milliseconds).

Maximum Time
Displays the maximum amount of time taken for the Ping Packet to echo back from the Remote device (in
milliseconds).

Average Time
Displays the average amount of time taken for the Ping Packet to echo back from the Remote device (in
milliseconds).

Blocks Tx’ed to Remote
Displays the number of data packets sent to the Remote device.

Blocks Rx’ed from Remote
Displays the number of data packets received from the Remote device.

Ping Quality
Displays the overall percentage of data packets sent vs. data packets received during the Ping Test.

Type of Data
Displays the type of Data Pattern to be used for each packet.
The size for each Data Pattern is shown below in Packet Size. The following lists the formats of the Data Patterns:
Page | 56
ASCII Pattern
The packets will be 52 characters in length. The pattern used to build the packets will have the following format (in
ASCII):
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
--ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ASCII Number Pattern
The packets will be 48 characters in length. The pattern used to build the packets will have the following format (in
ASCII):
00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
--00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
Binary Pattern
The packets will be 16 characters in length. The pattern used to build the packets will have the following format (in
Hex):
00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
--00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
Random Binary Pattern
The packets will be 16 characters in length and contain random binary data.

Packet Size
Packet Size displays the number of bytes in each packet.

# of Packets/Block
Displays the number of packets in each transmission block

Total Bytes/Block
Displays the total number of blocks in each transmission block

# Blocks to Send
Displays the number of blocks to be sent to the Remote device (after selected number has been sent, transmission
automatically stops).

Block Delay
Displays the amount of time (in seconds) of delay between each block transmission (range is from
0.000 to 5.000 seconds in 0.125 second intervals). Block Delay is user programmable.
Page | 57

Start
Begins the Ping Test.

Stop
Stops the Ping Test.

Save
Offers the user the option to save the information received from the test.

Close
Closes the Ping Test window.
4.4.12 ASCII/HEX TERMINAL
The ASCII and Hex Terminal Screens are accessed from the Utilities pull-down menu and allow the user to select an ASCII,
Hexadecimal TCP Socket or UDP Socket Terminal Screen for the Primary and Secondary COM Ports (configured in the Port
Settings screen - see Section 4.4.1) Data is sent according to the port configuration set up in the Port Settings screen.
4.4.12.1 ASCII TERMINAL
From the Programmer Window, Select Utilities – ASCII Terminal. ASCII Terminal configurations are defined below.
Figure 39: ASCII Terminal Screen
Primary
The Primary ASCII Terminal screen allows the user to send and receive ASCII data on the Primary COM Port (setup in the
Port Settings screen).
Page | 58
Secondary
The Secondary ASCII Terminal screen allows the user to send and receive ASCII data on the Secondary COM Port (set up in
the Port Settings screen).
TCP Socket
The TCP Socket Terminal screen allows the user to send and receive ASCII data over a TCP connection.
UDP Socket
The UDP Socket Terminal screen allows the user to send and receive ASCII data over a UDP connection.
4.4.12.2 HEX TERMINAL
From the Programmer Window, Select Utilities – Hex Terminal. Hex Terminal configurations are defined below.
Figure 40: HEX Terminal Screen
Primary
The Primary Hex Terminal screen selects a Hexadecimal Terminal screen to send and receive Hexadecimal data on the
Primary COM Port (set up in the Port Settings screen).
Secondary
The Secondary Hex Terminal screen selects a Hexadecimal Terminal screen to send and receive Hexadecimal data on the
Secondary COM Port (set up in the Port Settings screen).
Page | 59
TCP Socket
The TCP Socket Terminal screen allows the user to send and receive Hexadecimal data over a TCP connection.
UDP Socket
The UDP Socket Terminal screen allows the user to send and receive Hexadecimal data over a UDP connection.
4.5
PROGRAM CODE MENU
The Program Code pull-down menu allows the user to update the Integra-TR firmware (*.bin) with the Program Firmware
option, Read Boot Code Version, Select Firmware File (allows the user to select the file to program the firmware in the
Integra-TR) or Upgrade Boot Code file. Selecting one of these options opens a standard navigation window to select the
desired file.
Figure 41: Select Firmware File Window (for reference only)
Page | 60
5
NETWORK OPTIMIZATION
Detailed system engineering is beyond the scope of this manual. However, there are some simple tips that can be used to
optimize performance of a radio based SCADA or telemetry system.
5.1
CHOOSE THE BEST PROTOCOL
Some SCADA devices allow a choice of more than one operating protocol. In some cases, performance can be improved by
selecting a different protocol. Contact Technical Service for assistance.
5.2
CHECK TIMER SETTINGS
Polling protocols issue a poll and wait a certain time for a response. Integra-TR adds a short amount of delay to each poll
and response (typically in the order of 60 to 70 ms). Timer settings that are too short may cause erroneous indication of
missed polls, in which case the application may retry or continue to cycle, ignoring the missed station. In this case, the
response may collide with the next poll, further increasing errors. Setting an adequate timer margin will avoid problems and
maximize performance.
5.3
AVOID FLOW CONTROL
Set the COM port baud rate to a value less than or equal to the radio network speed (2400, 4800, 9600 or 19200 b/s). In a
polling system, this will prevent buffer overflow with possible missed transmissions. If the port baud rate must be set higher
than the radio network speed, you may have to limit message length to prevent possible buffer overflow. Integra-TR will
exert a flow control signal (CTS dropped) if buffers are almost full, but not all DTE honor such signals.
5.4
USE THE HIGHEST SUIT ABLE PORT BAUD RATE
Do not exceed the radio network speed. Operating an RTU at 1200 b/s on a 9600 b/s network will increase data
transmission delays and reduce system performance.
5.5
EVALUATE THE NEED FOR ONLINE DIAGNOSTICS
Enabling online diagnostics increases delays by 2.5 to 20 ms (depending on speed). In critical applications, this extra delay
can be eliminated by disabling online diagnostics. Offline Diagnostics (diagnostics on request) remain available.
5.6
INTERPRETING RSSI READINGS
Typical values of RSSI will be in the range of -110 to -60 dBm (depending on network speed), with higher values (i.e. less
negative values) indicating a stronger signal.
Reliability of data reception depends largely on signal strength. Good design practice calls for a minimum 30 dB “fade
margin”, based on a threshold reception level of -107 dBm (1 uV) at speed of 9600 b/s. Experience indicates that this will
give about 99.5% reliability.
Page | 61
Some representative performance values for 9600 b/s operation are given below. These values assume that the units are
correctly aligned and installed in a quiet location. Environments with high electrical or RF noise levels will require an
increase (less negative) in the numbers shown to achieve a given level of reliability.
-100 dBm Approximately 50% reliability. Fading may cause frequent data loss.
-90 dBm Approximately 90% reliability. Fading will cause occasional data loss.
-80 dBm Approximately 99% reliability. Reasonable tolerance to most fading.
-70 dBm Approximately 99.9% reliability with high tolerance to fading.
If RSSI values drops seasonally the most likely cause is tree foliage which can interfere with radio transmissions during the
spring and summer.
5.7
INTERPRETING POWER READINGS
The values returned are approximate and should not be regarded as an absolute indicator of performance. For example, a
unit that shows a forward power of 4.5 watts may actually measure at 5.0 watts on a lab quality wattmeter. For this reason,
these values should not be used to indicate that a unit is out of spec or to compare one unit to another.
However, the values returned should be consistent for any given unit. If statistics are kept on a unit per unit basis, changes
in forward or reflected power are significant. The following conditions are worthy of investigation.
1.
2.
5.8
Forward power output (in watts) drops or rises by more than 10% from its established value. Reflected power
remains low. This indicates that the transmitter may need alignment or that a component may be in need of
replacement.
Forward power output drops by more than 10% from its established value or reflected power shows an increase.
This indicates a possible antenna or feedline problem that affects SWR (Standing Wave Ratio).
SWR AND REVERSE POWER
A reverse power reading above zero is an indication that the antenna, feedline or connectors are damaged, corroded or
improperly tuned. This creates standing waves that are reported as a Standing Wave Ratio (SWR). Table 9 is based on a
forward power of 5 watts (it may be scaled for lower power settings) and gives guidelines to interpreting these figures:
Table 9: SWR/Rev Power Interpretation
SWR
Rev Power
Significance
1:1
Ideal situation
1.5:1
0.2
Normal operation
2:1
0.6
Should be investigated
3:1 or greater
1.25 or greater
Defective antenna, feedline, or connectors
Should values returned by the built-in diagnostics seem to indicate a problem, verify using proper radio shop equipment.
Page | 62
6
DEFINITIONS
Dribble bits
Extraneous bits delivered at the end of a data transmission. These bits are equivalent to a “squelch
tail” in voice systems.
COM Port
The Communications Port of the wireless device. This port is configured as DCE and is designed to
connect directly to DTE.
CTS
Clear to Send. An RS-232 output signal from Integra-TR indicating that it is ready to accept data (used
in RTS mode).
DCE
Data Communications Equipment. This designation is applied to equipment such as modems. DCE is
designed to connect to DTE.
DOX
Data Operated Transmit. A mode of operation in which Integra-TR begins a transmission as soon as
data is presented to the RS-232 port.
DTE
Data Terminal Equipment. This designation is applied to equipment such as terminals, PCs, RTUs, PLCs,
etc. DTE is designed to connect to DCE.
FPS
Field Programming Software. Windows based software used in the programming and configuration of
a variety of CalAmp serial products.
Full Channel
Radio channel bandwidth equal to 25 kHz
Half Channel
Radio channel bandwidth equal to 12.5 kHz
Multi-Channel
The Integra-TR has multi-channel capability under system PLC control for advanced network
monitoring.
Network speed
Refers to the bit rate of the RF link between units. This rate is often different from COM port baud
rate.
PLC
Programmable Logic Controller. An intelligent device that can make decisions, gather and report
information, and control other devices.
Refarming
Strategy for using the radio spectrum more efficiently to meet future communications requirements
and the FCC's minimum bit rate requirements with speeds up to 19200 in Full Channel and 9600 in
Half Channel.
RTS
Request to Send. RS-232 input signal to Integra-TR indicating that the DTE has data to send. RTS may
optionally be used as a transmit switch for Integra-TR.
RTS mode
A mode of operation in which Integra-TR begins a transmission when RTS is raised and continues
transmitting until RTS is dropped.
RTU
Remote Terminal Unit. A SCADA device used to gather information or control other devices.
SCADA
Supervisory Control And Data Acquisition. A general term referring to systems that gather data and/or
perform control operations.
Setup Port
The configuration / diagnostic port of Integra-TR. This port is designed to be connected to a PC
running the Integra Field Programming Software.
Transparent
A transparent unit transmits all data without regard to special characters, etc.
Page | 63
ABOUT CALAMP
CalAmp is a leading provider of wireless communications products that enable anytime/anywhere access to critical
information, data and entertainment content. With comprehensive capabilities ranging from product design and
development through volume production, CalAmp delivers cost-effective high quality solutions to a broad array of
customers and end markets. CalAmp is the leading supplier of Direct Broadcast Satellite (DBS) outdoor customer premise
equipment to the U.S. satellite television market. The Company also provides wireless data communication solutions for the
telemetry and asset tracking markets, private wireless networks, public safety communications and critical infrastructure
and process control applications. For additional information, visit www.calamp.com.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 64
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Office Word 2007
Creator                         : Terri Grimm
Creator Tool                    : Microsoft® Office Word 2007
Create Date                     : 2013:04:24 11:51:40-05:00
Modify Date                     : 2013:04:24 11:51:40-05:00
Document ID                     : uuid:2FF3FE1D-CCC2-4F8D-87B3-7CA88E704B68
Instance ID                     : uuid:2FF3FE1D-CCC2-4F8D-87B3-7CA88E704B68
Part                            : 1
Conformance                     : B
Author                          : Terri Grimm
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NP44048551

Navigation menu