Cambium Networks 89FT0037 cnPilot e502S Outdoor User Manual E501S QSG V1

Cambium Networks Inc. cnPilot e502S Outdoor E501S QSG V1

User Manual QSG

Drill 4 holes of Ø6mm (Ø0.25”Inch) on wall. Press fit plastic anchor and assembly fastener. Leave 5mm to 6mm gap between wall and fastener head.Use the four mounting slots given on the back of the radio to mount to the wall.IntroductionTool Requirements• Phillips screwdriver (Wall Mounting)• Flat head screwdriver         (Pole Mounting)• 12 mm wrench          (Pole Mounting)community.cambiumnetworks.comJOIN THE CONVERSATIONThis guide provides quick installation steps for cnPilot F4 Access Points (APs). Package ContentsPole mounting bracketPoE Injector Cable glandH6 Access PointAlign Radio to required angle by tilting up and down. The maximum radio tilting angle is ± 40°, with an incremental of 10°.Radio holderHose clamp (Qty. 2)Power CordQuick Start GuideTools RequiredWall mounting kit (Qty. 4)M12 x 60 Bolt M12 Nut & WasherSTEP 1 (Pole Mount)Assemble the radio holder to the pole mounting bracketand secure it with M8 nuts by applying 3.0 Nm torque. STEP 2 (Pole Mount)Insert hose clamps through pole mounting bracket and clamp to pole by applying 3.0 Nm torque.STEP 3 (Pole Mount)Align the radio chassis with the guide rails of radio holder and slide it downwards until it clicks into place.Cable gland componentsComponentsGland AssemblyCable gland assembly sequenceCap Plastic Seal Body6. Assembled cable gland.5. Assemble cap and body.4. Insert seal into body.3. Insert seal into the plastic.2. Put seal over the cable.1. Pass cable through cap.STEP 4 STEP 5 (Pole Mount)Insert RJ45 to radio housing and the lock cable gland to radio housing with 1.5Nm to 2Nm torque. STEP 6 (Radio alignment) Wall MountingcnPilot H6 DF:/$16HFWRU$FFHVV3RLQW,3,QGXVWULDO*UDGH*LJDELW:L)L108100
Quick Link SetupConfigure Management PC Hardware OverviewHardware OverviewPowering UpOnline ResourcesUsing a web browser, navigate to 169.254.1.1 and login with username: admin and password: adminNavigate to the Quick Start menu and click the ‘Go To Next Page’.Configure your Region and Country of operation. Click the ‘Go To Next Page’. Configure the Carrier Frequency. Click the ‘Go To Next Page’.Select the Synchronization source. Click the ‘Go To Next Page’. Configuration - IP Address, a Subnet Mask, and a Gateway IP Address OR DHCP state to Enabled to have the IP address, subnet mask, and gateway IP address automatically configured by a DHCP server. Click the ‘Go To Next Page’.Click the ‘Save Changes’ button. Click the ‘Reboot’ button. 1. 2.3.4.5.6.7.1. 2.3.Connect the Ethernet cable from Eth1/PoE-IN of HV to the PoE port of  Gigabit Data + Power Connect an Ethernet cable from your LAN or Computer to the Gigabit Data port of the PoE adapter. Connect the Power Cord to the adapter, and then plug the Power Cord into a power outlet.Once powered ON -- Power LED should illuminate continuously on PoE Adapter.**Shielded Category 5 (or above) cabling should be used for all outdoor wired Ethernet connections and should be grounded through the AC ground of the PoE.RoHS/WEEE ComplianceCaring for the Environment: RoHS/WEEEEuropean Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.CE MarkingCE marking on this product represents the product is in compliance with all directives that are applicable to it.Alert Sign (!) Follows CE MarkingAlert sign must be indicated if a restriction on use applied to the product and it must follow the CE marking.FCC ComplianceChanges or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.7KLVGHYLFHFRPSOLHVZLWK3DUWRIWKH)&&5XOHV2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQV7KLVGHYLFHPD\QRWFDXVHKDUPIXOLQWHUIHUHQFHDQGWKLVGHYLFHPXVWDFFHSWDQ\LQWHUIHUHQFHUHFHLYHGLQFOXGLQJLQWHUIHUHQFHWKDWPD\FDXVHXQGHVLUHGRSHUDWLRQ)&&5DGLDWLRQ([SRVXUH6WDWHPHQW7KLVHTXLSPHQWFRPSOLHVZLWK)&&UDGLDWLRQH[SRVXUHOLPLWVVHWIRUWKIRUDQXQFRQWUROOHGHQYLURQPHQW7KLVHTXLSPHQWVKRXOGEHLQVWDOOHGDQGRSHUDWHGZLWKPLQLPXPGLVWDQFHFPEHWZHHQWKHUDGLDWRU\RXUERG\7KLVHTXLSPHQWKDVEHHQWHVWHGDQGIRXQGWRFRPSO\ZLWKWKHOLPLWVIRUD&ODVV%GLJLWDOGHYLFHSXUVXDQWWR3DUWRIWKH)&&5XOHV7KHVHOLPLWVDUHGHVLJQHGWRSURYLGHUHDVRQDEOHSURWHFWLRQDJDLQVWKDUPIXOLQWHUIHUHQFHLQDUHVLGHQWLDOLQVWDOODWLRQ7KLVHTXLSPHQWJHQHUDWHVXVHVDQGFDQUDGLDWHUDGLRIUHTXHQF\HQHUJ\DQGLIQRWLQVWDOOHGDQGXVHGLQDFFRUGDQFHZLWKWKHLQVWUXFWLRQVPD\FDXVHKDUPIXOLQWHUIHUHQFHWRUDGLRFRPPXQLFDWLRQV+RZHYHUWKHUHLVQRJXDUDQWHHWKDWLQWHUIHUHQFHZLOOQRWRFFXULQDSDUWLFXODULQVWDOODWLRQ,IWKLVHTXLSPHQWGRHVFDXVHKDUPIXOLQWHUIHUHQFHWRUDGLRRUWHOHYLVLRQUHFHSWLRQZKLFKFDQEHGHWHUPLQHGE\WXUQLQJWKHHTXLSPHQWRIIDQGRQWKHXVHULVHQFRXUDJHGWRWU\WRFRUUHFWWKHLQWHUIHUHQFHE\RQHRIWKHIROORZLQJPHDVXUHVThis radio transmitter (;)'5) has been approved by FCC to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.Antenna Information: Dual-band dual-polarized antenna)RUSURGXFWDYDLODEOHLQWKH86$&DQDGDPDUNHWRQO\FKDQQHOaFDQEHRSHUDWHG6HOHFWLRQRIRWKHUFKDQQHOVLVQRWSRVVLEOH3URIHVVLRQDOLQVWDOODWLRQLVUHTXLUHG7KLVGHYLFHDQGLWVDQWHQQDVPXVWQRWEHFRORFDWHGRURSHUDWLQJLQFRQMXQFWLRQZLWKDQ\RWKHUDQWHQQDRUWUDQVPLWWHUSafety NoticeWarning:To prevent loss of life or physical injury, observe the following safety guidelines. In no event shall Cambium Networks be liable for any injury or damage caused during the installation of H6 platform. Ensure that only qualified personnel install.Only use attachments/accessories specified by the manufacturer.Electrical Safety InformationCompliance with manufacturer’s label for voltage, frequency, and current requirements. Connecting to a dierent power source than those specified may result in improper operation, damage to equipment or pose a fire hazard if the limitations are not followed.There are no serviceable parts inside this equipment. Service should be provided only by a qualified service technician.This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.Protective bonding must be installed in accordance with local national wiring rules and regulations.1.2.3.a.b.c.d.e.Select Properties for the Ethernet port. In Windows it is found in Control Panel > Network and Internet > Network Connections > Local Area Connection.IP Address Configuration  Default IP address received via DHCP.cn Pilot H6 will use a default static IP address of 192.168.0.1, If there is no DHCP serverDefault Login information- Username: admin- Password:  adminManagement Protocols enabled by default –http or https (webpage management interface access), SSH (CLI management interface access). 1. 2.3.SpecificationsSecondary Port The Secondary port is a Gigabit Ethernet port used for bridging.Reset  The Reset button serves two functions for H6:- To restart, press and release the Reset button quickly.- To restore to factory default settings, press and hold theReset button for more than 10 seconds.Main  Port The Main port is a Gigabit Ethernet port used to connect the power and should be connected to the LAN and DHCP server.Main PortReset ButtonSecondary PortSystem LEDNetwork LEDUser Guide and software downloads:https://support.cambiumnetworks.com/files/e500/Support:http://www.cambiumnetworks.com/support/Contact us:http://www.cambiumnetworks.com/support/contact-support/,C Compliance7KLVGHYLFHFRPSOLHVZLWK,QGXVWU\&DQDGDOLFHQVHH[HPSW566VWDQGDUGV2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQVWKLVGHYLFHPD\QRWFDXVHLQWHUIHUHQFHDQGWKLVGHYLFHPXVWDFFHSWDQ\LQWHUIHUHQFHLQFOXGLQJLQWHUIHUHQFHWKDWPD\FDXVHXQGHVLUHGRSHUDWLRQRIWKHGHYLFH/HSUpVHQWDSSDUHLOHVWFRQIRUPHDX[&15G,QGXVWULH&DQDGDDSSOLFDEOHVDX[DSSDUHLOVUDGLRH[HPSWVGHOLFHQFH/H[SORLWDWLRQHVWDXWRULVpHDX[GHX[FRQGLWLRQVVXLYDQWHVODSSDUHLOQHGRLWSDVSURGXLUHGHEURXLOODJHHWOXWLOLVDWHXUGHODSSDUHLOGRLWDFFHSWHUWRXWEURXLOODJHUDGLRpOHFWULTXHVXELPrPHVLOHEURXLOODJHHVWVXVFHSWLEOHGHQFRPSURPHWWUHOHIRQFWLRQQHPHQW)RUSURGXFWDYDLODEOHLQWKH86$&DQDGDPDUNHWRQO\FKDQQHOaFDQEHRSHUDWHG6HOHFWLRQRIRWKHUFKDQQHOVLVQRWSRVVLEOH3RXUOHVSURGXLWVGLVSRQLEOHVDX[eWDWV8QLV&DQDGDGXPDUFKpVHXOOHFDQDOjSHXYHQWrWUHH[SORLWpV6pOHFWLRQGDXWUHVFDQDX[QHVWSDVSRVVLEOH,&5DGLDWLRQ([SRVXUH6WDWHPHQW7KLVHTXLSPHQWFRPSOLHVZLWK,&566UDGLDWLRQH[SRVXUHOLPLWVVHWIRUWKIRUDQXQFRQWUROOHGHQYLURQPHQW7KLVHTXLSPHQWVKRXOGEHLQVWDOOHGDQGRSHUDWHGZLWKPLQLPXPGLVWDQFHFPEHWZHHQWKHUDGLDWRU\RXUERG\&HWpTXLSHPHQWHVWFRQIRUPHDX[OLPLWHVGH[SRVLWLRQDX[UD\RQQHPHQWV,&pWDEOLHVSRXUXQHQYLURQQHPHQWQRQFRQWU{Op&HWpTXLSHPHQWGRLWrWUHLQVWDOOpHWXWLOLVpDYHFXQPLQLPXPGHFPGHGLVWDQFHHQWUHODVRXUFHGHUD\RQQHPHQWHWYRWUHFRUSV

Navigation menu