Camden Door Control TX9 TX-9 Transmitter User Manual Manual

Camden Door Control TX-9 Transmitter Manual

Rev User Manual

LazerpointTM RF TX-9Transmitter  Installation InstructionsVer.  1.01                 General DescriptionCamden Lazerpoint™ Radio Controls comprise the following models:CM-TX-9 Wall switch ready transmitterCM-RX-91 Basic ReceiverCM-RX-92 Full function (dual relay) Receiver.TX-9 transmitters utilize readily available AAA batteries, and special circuitry to assure long life.A proprietary piezo sounder is used to annunciate low battery, battery level, and “stuck switch” conditions.These instructions cover the TX-9 transmitter.MountingThe TX-9 is designed to mount behind a switch in a wall-box, post, or other suitable enclosure. Double sided tape is used to attach the circuit board and battery holder securely to the enclosure. Even though the circuit board is conformal coated, care should be taken to ensure the transmitter does not get wet.WiringRefer to the TX-9 Installation Drawing (see reverse side) for the following connections:Connect the transmitter wires to the activating switch (N.O. momentary dry contacts). Insert 2 fresh AAA alkaline batteries (provided) into the battery holder (observe proper polarity).  Press the switch and observe the red LED to ensure proper transmission.Test the transmitter by pressing and holding the switch for 5 seconds. The piezo speaker should sound 5 beeps, meaning the batteries are at full capacity.  This is the Battery Gauge™ feature.If the piezo beeps only 1 - 3 times, you should change the batteries for fresh (new) ones.Now press and hold the switch for 15 seconds. The piezo should now make a distinctive hi-low sound. This signal will sound for 6 seconds, then turn off for a minute, then sound again. This is the “stuck switch indicator” feature.Learning the Transmitter(s) to the ReceiverTo learn the transmitter into the receiver, press the PB1  (or PB2) button on the Receiver using a small blunt object such as a small blade screwdriver or similar.  Within 10 seconds, press the switch connected to the TX-9 transmitter.  The Green LED Array will flash once to confirm enrolment.  Repeat with any additional transmitters.  Pressing the learned transmitter again will signal the receiver that you are finished programming and LED’s 1 & 2 will flash, in an alternating sequence.  Pressing the transmitter a third time will activate the relay and corresponding LED, and also the device connected to the relay contacts.If you wait longer than the 10 second period, the receiver will time out of Learn Mode and revert back to standby. The LED will then flash to indicate the number of transmitters learned into the receiver.Technical DataModel   TX-9 TransmitterFrequency:                   Operates in the 902 – 928 MHz     ISM BandCodes      1 million (20 bit) codesSize      2 ¼” L x 5/8” W x 3/8” HMounting    Double sided foam tapeSwitch Connection  2 x 10” leads with ¼” quick     disconnect terminationsBuilt-in Piezo sounder  Used for Low Battery status,        Battery Gauge™, and Stuck     Switch indicator.Power      2 x AAA alkaline batteriesBattery life    Minimum 500,000 operationsRange      Over 500 ft (open area)Temperature rating  -40 o to 185o F (-40 o to +85 o C)WarrantyCamden Door Controls guarantees the Lazerpoint™ RF (TX-9, RX-91,or RX-92 models) to be free from manufacturing defects for 3 years from date of sale. If during the first 3 years a Lazerpoint RF component fails to perform correctly, it may be returned to our factory where it will be repaired or replaced (at our discretion) without charge.  Except as stated herein, Camden extends no warranties expressed or implied regarding function, performance or service.NOTE: Batteries are exempt from this warranty!Page 1 of 3
FILENAME: TX-9 Installation Drwg.vsdDRAWING No: TX-9-InstallationTX-9 Typical Installation ExamplesSCALE:  NONE DRAWN BY: DGWREVISED:  16/09/15DATE:  03/24/105502 Timberlea BlvdMississauga, OntarioL4W 2T7+-+-+-+-+-+-STEP 1STEP 2aSTEP 2bORInsert two fresh AAA batteries intobattery holder, taking care to match thepositive and negative terminal markingson case.USING WITH OUR CM-45 SWITCH & CM-43 BOXPeel off the release paper on the back of the transmitterand batter holder.Position on back of the enclosure ensuring clearance forthe switch (as shown above).Connect the two red leads to the N.O. and Commonterminals of the switch and mount switch to enclosure.Test for proper operation.USING WITH OUR CM-25 SWITCH & CM-23d BOXPeel off the release paper on the back of the transmitter andbattery holder.Position on each side of the enclosure ensuring batteryholder is tight to the bottom of box (as shown above).Cut off the two ¼" Female connectors, and strip wires.Connect to the two leads from switch using small twist-onMARR connectors.Install switch to box, and test for proper operation.Part # 40-82B120++AAAAAACOMN.O.AAAAAAPUSHTOOPENAffix batteryholder to side ofbox as close tobottom aspossibleCamden Door ControlsLazerpoint™ RF TX-9 Transmitter Installation InstructionsPage 2 of 3
IC & FCC INFORMATION FOR USERSIC: 8725A-TX9This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:(1) This device may not cause interference; and(2) This device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :1) l’appareil ne doit pas produire de brouillage;2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.FCC ID: 2AHAB-TX9This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:—Reorient or relocate the receiving antenna.—Increase the separation between the equipment and receiver.—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.—Consult the dealer or an experienced radio/TV technician for help.Changes or modications made to this equipment not expressly approved by Camden Door Control could void the user’s authority to operate the equipment.OEM Labeling RequirementsWARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the nal product enclosure that displays the contents shown in the gure below.Required FCC Label for OEM products containing the CM-TX-9 Module.Contains FCC ID: 2AHAB-TX9 & IC: 8725A-TX9This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interferences that may cause undesired operation.IMPORTANT: OEMs must test nal product to comply with unintentional radiators (FCC section 15.107 & 15.109) before declaring compliance of their nal product to Part 15 of the FCC Rules.Page 3 of 3Lazerpoint™ RF TX-9 Transmitter Installation InstructionsPush Buttons Key Pads Strikes Magnetic Locks Key Switches Relays & Timers Access Control5502 Timberlea Blvd., Mississauga, ON Canada L4W 2T7www.camdencontrols.com Toll Free: 1.877.226.3369File: Lazerpoint RF TX-9 Manual .indd  Rev.6 Revised: 19/05/2016 Part No.: 40-82B120

Navigation menu