Your CL5000 is a very powerful LTE communications gateway that can monitor and provide remote control from any cellular
phone. In order to make it as accessible and as simple to use as possible, we have provisioned CL5000 at the factory to
perform the more common functions "out of the box". It has many capabilities that we do not mention here, so contact us for
any special requirements. First follow the separately provided instructions for the installation of the CL5000 into your
application.
Loading SIMCARD
If your CL5000 did not ship with a SIMCARD. NOTE: YOU MUST disconnect all external power supply connections when
changing SIMCARD.
Remove screws.
Make sure the Battery is disconnected.
Locate the SIMCARD holder on the modem sub-board. Gently push an activated simcard into the holder until
it clicks and holds in place.
Next, take the small white plug from standby battery and slide it into the power socket.
This only goes in one way. Do NOT force.
You are now ready to load the phone numbers. Test with just one cellphone first, then load others later as
required.
Set up your phone to send a text message (SMS) TO the phone number issued with the SIMCARD that
you just loaded into CL5000. The SIMCARD phone number will have been issued along with the SIM card
by the network provider. The first message you must send CL500 is your cell phone number. Send the
following text message::
ADDPHONEn<>88888888<>+(country code)(area code)(your cellphone number) (n is ph 1 to ph 4.)
eg : ADDPHONE3 88888888 +121234567899 (This is loaded as ph # 3)
Spaces are indicated by <>. Don’t insert any spaces in the phone number itself. The eight 8's are a factory
password that you should change later.
Now send this off CL5000 should respond with a confirmation message. If no response is received within
about 3 minutes, it means it either did not receive the message or there was a syntax error in the command.
If this worked, you can close the unit up again carefully.
ADDING PHONE NUMBERS
You can store up to four phone numbers. Add them using
ADDPHONEn<>PASSWORD<>+(country code)(area code)(your cellphone number)
eg : ADDPHONE3 88888888 +121234567899 (this is loaded as Ph. # 3)
LOADING the SIMCARD PHONE NUMBER
Most SIMCARDS do not have a phone number stored internally, so you need to load the number assigned to the SIMCARD
by the network provider. Do this by sending CL5000 the following command:
2
DEVPH<>+(country code)(area code)(SIMCARD phone number)
eg: DEVPH +121234567899
If you don’t add the Device Phone number, CL5000 will still work, but the TIME will not be updated from the network
.
LIST REGISTERED PHONES
To check the four recipient phone numbers stored in CL5000. Send the following command:
GETPH
REMOVING a PHONE NUMBER
Send the following text to your CL5000
RMPH <>PASSWORD<> +(country code)(area code)(phone number) (n is ph # 1 to 4)
eg: RMPH2 <>88888888 +12141234567899 ( this removes ph # stored as #2)
To change a number, you can load the new number over the old using ADDPHONE. If there is no room left, CL5000 will
advise with a message.
CHANGING PASSWORD
To change the password, send CL5000 the following text message;
PASSWORD<>OLD password<>NEW password
eg: PASSWORD 88888888 12345678
"REPORT xy//info" sets CL5000 up to send an AUTOMATIC "INFO" report every "xy" hours.
"TEMPRESET" alone, resets the Temperature Logs to present ambient temperature.
"TEMPRESET <>F(or C)<> Max Temp// Min temp " F or C selects units, <> is a space, Max and Min
temps sets the maximum and Minimum ALERT temperatures, Range is 14 F (-10 C) to 176 F ( 80 C).F:
Fahrenheit,
C: Centigrade. Eg: TEMPRESET F 110//38
"HELP" responds with Help info on command syntax.
TEMPDEL n Temperature delay in minutes (n). Use to reduce transient alarms.
PWRDEL n Power loss alert delay in minutes (n). Use to reduce transient alarms.
ARM Activates SMS messaging ( Factory default)
DISARM Disables all SMS messaging.
ASK<>code Used in USSD enabled networks to request network subscriber data like prepaid simcard
balance amount. If code to get simcard dollar balance is say *120# from your cellphone,
then send CL5000 the code as ASK *120# and it will return the network message with this
information. Does not work with voice-only services. Requires USSD service.
PLE Power Loss alert ENABLE.
PLD Power Loss alert DISABLE.
3
EXTVOLT ON//v.v Alarm voltage setpoint for low voltage alert. Sets value to send alarm.
Eg EXTVOLT ON//11.8 Use in conjunction with PWRDEL delay time value to avoid
transient alarms. OFF/ON.
E1D n Add a Time delay of n minutes to switch n. Use to avoid transient alarms.
DATARESET Resets configuration to Factory default. Use with care. Custom changes will be lost.
CTXSO<n><space><msg> Change Switch (n) OPEN message to "msg".
CTXSC<n><space><msg> Change Switch (n)CLOSED message to " msg".
COMMAND STRINGS
CL5000 will accept multiple commands in the same text message as long as they are each separated by a
semi colon.
eg; GETSIG;INFO;TAMPER
QUESTIONS and TROUBLESHOOTING
Please refer to our website for Frequently asked questions and troubleshooting guidelines.
Regarding JBP, please see as follow information
"JBP" is the equipment class code assigned by the Commission to designate Part 15 Class B
Computing Device Peripherals on FCC Form 731
FCC Compliance
Section 15.21 Information to user
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment
Section 15.19 Labeling requirements:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.
Section 15.105 (b)
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
--Consult the dealer or an experienced radio/TV technician for help.
4
IMPORTANT NOTE:
To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter
must be installed to provide a separation distance of at least 20 cm from all persons and must not
be co-located or operating in conjunction with any other antenna or transmitter”
NOTE:
The manufacturer accepts no liability for the applications or uses made by its products under any
circumstances, including Cellular network, location services, or device failure, for whatever reason.
The manufacturer reserves the right to change the specifications, functionality and instructions of its
products and accessories, at any time without notification.
Thank you for purchasing your CL5000.

Navigation menu