Introduction
This is the Supra Wireless TRACcess Interface Retrot
Installation Instructions. Read these instructions before
replacing the bezel interface with the wireless interface. If
you do not mount the interface accurately, it will not function
properly. Supra will not be responsible for replacing the
interface if it is damaged or destroyed upon removal.
Installation supplies provided
• Drill template
• Electronics enclosure with lid
• Mounting plate (interior)
• Exterior WTI interface plate
• Three 9-volt batteries
• Foursetsoffour#8atheadscrews(fourdifferent
screw lengths for the mounting plate)
• Last battery change sticker
• Oneelectriedlockset(nolockcore)
• Four #8 × 5/16 in. panhead screws and lock
washers (for electronics enclosure)
• Six#4×1/2in.atheadscrews
• Plastic weather cover
CAUTION: The electronics in this package are
electrostatic sensitive devices. Before you install the
unit, discharge or use a grounding belt.
Installation tools required
• Drill
• Drill bits
• File
• Phillips screwdriver
• Level or punch
• Pen or pencil
P/N10103022P1•October2011
© 2011 UTC Fire & Security. All rights reserved.
Wireless TRACcess Interface Retrot
Installation Instructions
Figure 1. Bezel interface and Wireless interface
Installation
To replace the bezel interface with the wireless interface:
1. Remove the screws from the electronics enclosure and
remove the electronics enclosure lid.
2. Disconnect the wiring plugged in to the electronics
enclosure.
3. Remove the screws that are securing the electronics
enclosure to the bezel interface and remove the
electonics enclosure.
4. Remove the bezel interface.
5. Feed the four-wire plug from the exterior WTI interface
plate through the hole in the door, and secure the
interior mounting plate to the exterior mounting plate
(Figure 2). Insert and tighten screws through interior
mounting plate. For 1-1/4 to 1-1/2 in. (32 to 38 mm)
doors, use 3/4 in. (19 mm) screws. For 1-1/2 to 2 in.
(32 to 51 mm), use 1-1/4 in. (38 mm) screws.
Note: If the screw does not fully secure the plates to the
door when tightened, use a shorter screw. Do not
overtighten the long screw.
6. Thread the four-wire plug from the wireless interface
plate, and the two-wire plug from the lockset through
the thread hole in the electronics enclosure. You will
attach the wires after securing the enclosure.
7. Using the four #8 × 5/16 in. (16 mm) panhead screws
and lock washers, attach the electronics enclosure to
theinteriormountingplate.Positioneachatwasher
against the inside surface of the electronics enclosure,
thenplacethelockwasherontopoftheatwasher,
and secure with the screw.
8. Attach the two-wire plug to the two prong connector.
Attach the four-wire plug to the four-wire connector.
9. Insert and connect the three 9-volt batteries to the
battery terminal connectors. Secure the batteries in the
battery holder compartment and make sure the wires
point toward you as you secure them in place. (Battery
connectors should point toward the circuit board).
10. Perform an Install function with a valid TRACcess
eKEY. Refer to the TRACcess eKEY user instructions
for step by step operation.
11. Test the lock operation using the TRACcess eKEY.
Refer to the TRACcess eKEY user instructions for step
bystepoperation.Testthelockrstwiththedooropen
and then with the door shut to ensure the lock strike
catches the door frame.
12. When you test the lock with your key, the LED at
thetopoftheinterfacewillashgreen,indicating
the door may be opened. If the device is a TRAC-
Station BT programmed for TIMED mode, the light
willremainashingforapreprogrammedperiod
of time, during which the door may be opened. If
the device is a TRAC-Station BT programmed for
LATCHEDmode,oncethelightashesgreen,the
door may be opened until the lock is reset. If it is
programmed for LATCHED mode, be sure to reset the
lock.
13. Once you have tested the lock, place the lid on the
back of the electronics enclosure and position the logo
directly over the battery pack. Insert the provided six
#4×1/2in.(13mm)atheadscrewsintothepredrilled
holes. Hand-tighten the upper right corner screw and
continue hand-tightening the remaining screws in a
clockwise order. Do not overtighten the screws, as
doing so may damage the electronics enclosure and
prevent the lid from being securely fastened.
14. Record the device serial number and location.
Battery removal/disposal
This product contains three 9-volt batteries if it is a TRAC-
Lock BT or three AA batteries if it is a TRAC-Station BT.
The batteries should be periodically replaced. Replacing the
interface is a good time to service the batteries. To remove
the batteries, do the following:
1. Remove the lid from the electronics enclosure.
2. Pull the batteries out of the slots.
For proper recycling, dispose of all batteries as required by
local ordinances or regulations.
FCC
The device, Assy, Bezel, WTI, part number 10102917G1,
complies with part 15 of the FCC rules. Operation is subject to
the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired operation.
Changesormodicationsnotexpresslyapprovedbytheparty
responsible for compliance could void the user’s authority to
operate the equipment.
2002/96/EC (WEEE directive). Products marked with this
symbol cannot be disposed of as unsorted municipal waste in
the European Union. For proper recycling, return this product
to your local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collection points.
Figure 2. TRAC-Station BT assembly
Supra:800-547-0252•www.suprasystems.com
Electronics
Enclosure
Exterior WTI
Interface
Plate
Interior
Mounting
Plate
Exterior
Mounting
Plate
Lockset
4-wire plug

Navigation menu