Carrier Fire and Security Americas GE616 Proximity Reader User Manual

UTC Fire & Security Americas Corporation, Inc Proximity Reader Users Manual

Users Manual

GE616 Proximity Reader Last Update August 24, 2005
GE616 Proximity Reader Last Update August 24, 2005
Table of Contents
1. Important safety instructions 3
2. Introduction 5
3. Identifying supplied parts 5
4. Specification 6
5. Installation 6
6. Wire Connection to Controller 7
7. Wire Color Table of the Reader 7
8. Operation 8
9. The Maximum Length of the Wiegand Cable 9
10. FCC Registration Information 10
11. Warranty and Service 11
GE616 Proximity Reader Last Update August 24, 2005
3
1. Important safety instructions
To prevent injuries to persons and damages to property, please
read all the instructions and follow them whenever you deal
with this product.
After reading, please put this instruction manual where it can be
easily seen for the system operator.
ON INSTALLATION AND POWER
Use 12V DC power ONLY.
- Connecting to higher than 12V DC may result in a risk of
electric shock, fire, or heavy damage
of the unit.
Do NOT install this product at places with wet or metallic dust,
or that can be watered.
- There may be risks of electric shock and fire.
Do NOT install this product near electric motors running.
- The unit may not operate normally.
Do NOT set this product near heaters or anything that
produces heat.
- There may be a risk of fire.
Be ALWAYS careful not to short-circuit any part of the circuitry
with tools like a screwdriver in hand.
- There may be a risk of fire or heavy damage of the unit.
GE616 Proximity Reader Last Update August 24, 2005
4
ON MAINTENANCE
Do NOT use any kind of liquid for cleaning.
- There may be a risk of electric shock, fire or heavy damage
of the unit.
Use an air spray, if needed.
Users are cautioned NOT to attempt repair of this product or
modify the wirings set by the installer at their own discretion.
- It may pose the risk of fire, hardware damages, or abnormal
operations of the unit.
It is recommended not to use a flammable spray or some-
thing easy to burn near this product.
- There may be the risk of an explosion or fire.
Keep the unit away from any unauthorized people.
- It may cause abnormal operations of the unit.
NOTICE
Please, contact a designated service center or the outlet at
which the product was purchased when
A. Any liquid has been spilt or sprayed onto the product.
In this case, cut the power off first.
B. The product seems to be operating abnormally.
C. The unit exhibits a distinct change in performance.
D. The unit has fallen to be broken down or damaged on
its case.
* The cost of repairing can be charged for troubles due
to the improper handling or negligence of users or
the operator.
GE616 Proximity Reader Last Update August 24, 2005
5
2. Introduction
The GE616 is an elegant looking and an attractive 4" read
range proximity reader which can be mounted to metal door
frame (mullion) or any flat wall surface. The GE616 is epoxy
potted that ensure you successful operation even in harsh
environments. Two colors LED of green and red, inside Piezo
buzzer sound will guarantee you an accurate and reliable
system operations.
3. Identifying supplied parts
Please unpack and check the contents of the box.
Reader
Module
GE616
Bezel Manual Screws
(1ea) (1ea) (1 copy) (4ea)
GE616 Proximity Reader Last Update August 24, 2005
6
4. Specification
5. Installation
5-1. Mullion/Wall Mount
Drill two 6-32 or M3 holes 3.3"(8.38cm) apart in vertical
and drill one 1/2" hole for the reader cable 1.7"(4.31cm) apart
from the top hole.
(If you have installed electric gang box then skip this step.)
5-2. Put reader cable into the center hole and install the
reader module by using two 6-32 or M3 screws.
5-3. Put bezel into the reader module then push bezel until you
hear the locking sound.
Read Range/Time Up to 4"(10cm) / 30ms
Input Voltage/Current DC 5V ~ 17V, Max. 100mA
Output Format 26 bit Wiegand
External Buzzer
Control Input
Low Active, DC 0 ~ 12V,
Max. 50mA
External LED
Control Input
Low Active, DC 0 ~ 12V,
Max. 50mA
LED/Buzzer 2 Color LED (Red and Green) / Piezo
Buzzer
Color Silver
Operating
Environment
-31 ~ 149(℉℉-35 ~ +65 )℃℃
10~90% Humidity, Non-Condensing
Overall Size (WxHxD) 1.82"x4.81"x0.87"(46x122x23mm)
Weight 0.35lb(160g)
GE616 Proximity Reader Last Update August 24, 2005
7
6. Wire Connection to Controller
GE616 Proximity Reader Last Update August 24, 2005
8
7. Wire Color Table of the Reader
POWER
Power(DC +5V~+17V) DC(+)
Red wire
Power(DC Ground) DC(-)(GND)
Black wire
INPUT
Buzzer control input
BUZZER Blue wire
LED control input LED
Yellow wire
OUTPUT(Wiegand Format)
Wiegand Data-0 Data-0
Green wire
Wiegand Data-1 Data-1
White wire
8. Operation
8-1. Apply power and you can see Red LED is on indicating the
reader is in standby.
8-2. Present proximity card to the reader until you hear beep
sound and the LED is changing the color to Green
simultaneously and the reader send RF card data to the
controller then LED changes the color to Red again for next
reading.
8-3. LED Control
To change the LED colors, you may connect LED Control
Input (Yellow wire) to power ground then the Green LED is
on indicating the reader is in standby.
Present proximity card then the LED changes the color
to Red simultaneously then Green again for next reading.
GE616 Proximity Reader Last Update August 24, 2005
9
8-4. Buzzer Control
When the reader reads proximity card, only one beep sound
generates in normal operating mode but you can generate
more beep sounds to distinguish whether the access is
granted or denied.
To generate more beeps, you may control the Buzzer
Control Input(Blue wire) to power ground then you can turn
beeper on while you hold Buzzer Control Input to power
ground.
9. The maximum length of the Wiegand cable
When use this reader with controller, length of the Wiegand
cable is maximum 150m on the following condition.
Controller and Cable
- Controller : GE313 or GE314
- Cable : AWG #22 twisted pair
GE616 Proximity Reader Last Update August 24, 2005
10
10. FCC Registration Information
FCC REQUIREMENTS PART 15
Caution: Any changes or modifications in construction of this device
which are not expressly approved by the responsible for compliance
could void the user's authority to operate the equipment.
NOTE: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions;
1. This device may not cause harmful interface, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class A Digital Device, pursuant to Part 15 of the FCC Rules.
These limits are designed to this equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
radio or television off and on, the user is encouraged to try to correct
interference by one or more of the following measures.
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on another circuit.
4. Consult the dealer or an experienced radio/TV technician for help.
GE616 Proximity Reader Last Update August 24, 2005
11
11. Warranty and Service
TWO YEARS LIMITED WARRANTY AND LIMITATION OF LIABILITY
GE Security warrants that this product will be free of defects in material and
workmanship for a period of two years from date of purchase under normal
consumer use. Losses caused by modification, improper installation or use,
abuse, and acts of God are not covered. GE’s obligation is limited to repair
or replacement of the defective product at GE’s option. This two years
Limited Warranty is in lieu of all other warranties, obligations, or liabilities on
the part of GE, and GE MAKES NO OTHER WARRANTY, EXPRESS OR
IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.GE does not, and cannot, know who is present what property is
located where this product will be used; it would be extremely difficult to
determine the actual damages that may result from a failure of the product to
perform as anticipated; and the low price of this product is based upon the
nature of the product provided and the limited liability that GE assumes.
Accordingly, GE SHALL HAVE NO LIABILITY FOR ANY PERSONAL
INJURY, PROPERTY DAMAGE OR LOSS, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES, OR OTHER LOSS, AND GE’S MAXIMUM
LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE
OF THE PRODUCT. Any action for breach of any warranty or other
obligation must be brought within twenty-four(24) months of the date of
purchase. Some states do not allow limitations on how long an implied
warranty lasts and/or do not aloe the exclusion of incidental or consequential
damages, so the above limitations may not apply to you. To obtain repair or
replacement information under the terms of this warranty, return the product
and proof of purchase along with owner’s name and address, postage
prepaid to: GE Security, Suites 503-506, 5/F Tower 1, The Gateway, 25
Canton Rd, TST, Kowloon, Hong Kong. This warranty gives you specific
legal rights and you may also have other rights, which vary based from
location to location.
GE616 Proximity Reader Last Update August 24, 2005
12
The specification contained in this manual are subject to change
without notice at any time.
GE Security Asia Ltd.
Suites 503-506, 5/F
Tower 1, The Gateway, 25 Canton Rd, TST.
Kowloon, Hong Kong
Tel: +852-28790022
Fax: +852-81472309
GE616 Proximity Reader Last Update August 24, 2005
13
MEMO
GE616 Proximity Reader Last Update August 24, 2005
14
MEMO
GE616 Proximity Reader Last Update August 24, 2005
15
MEMO

Navigation menu