Carrier 42Vmc Users Manual
42VMC to the manual 9f948fb9-7eb6-44a2-8dc7-b4c8d2858913
2015-01-24
: Carrier Carrier-42Vmc-Users-Manual-310539 carrier-42vmc-users-manual-310539 carrier pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
42VMC The St rm al u INSTALLATION MANUAL ISO 9001 Q Console SI el sra fI ds Institution dar o an ity Assured Fi The operation and maintenance instructions for the indoor unit and the installation instructions for the indoor and the outdoor unit are given in the manuals for each unit. These are supplied with the unit. Contents Page Dimensions and weight............................................................................... 2 Nominal data ............................................................................................... 2 Minimum clearances ................................................................................... 2 Connections ................................................................................................ 3 Material supplied ........................................................................................ 3 Operating limits ........................................................................................... 3 General information .................................................................................... 4 Warnings: avoid .......................................................................................... 5 Installation .................................................................................................. 6/7 Refrigerant connections ............................................................................. 8 Electrical connection .................................................................................. 9/11 System configuration .................................................................................. 12 Operating test ............................................................................................. 13 Address selector ......................................................................................... 13 Fault code ................................................................................................... 13 Guide for the owner ..................................................................................... 13 Accessories ................................................................................................ 13 Air delivery .................................................................................................. 14 Fresh air renewal ........................................................................................ 14 Cooling only and heat pump models ENGLISH 42VMC Split system “Console night & day” indoor unit Power supply 42VMC009 42VMC012 42VMC014 230V ~ 50Hz 42VMC018 42VMC024 GB - 1 42VMC Dimensions and weights - Minimum clearances (mm) Dimensions and weights Minimum clearances Wall installation A B 500 min 200 50 min 40 Ceiling installation Ø 80 50 50 min Model 42VMC009 42VMC012 42VMC014 42VMC018 42VMC024 A mm 850 850 1000 1000 1000 B mm 540 540 600 600 600 kg kg 15 16 18 18 20 Table I: Nominal data POWER INPUT Cooling only • Unit is not suitable for operation in laundry premises. Cooling W Heating W 42VMC 009 25 – 42VMC 012 30 – 42VMC 014 55 – 42VMC 018 55 – 42VMC 024 80 – Heat pump 42VMC 009 25 25 42VMC 012 30 30 42VMC 014 55 55 42VMC 018 55 55 42VMC 024 80 80 GB - 2 • For sizing of power supply wires and delay type fuses, refer to the outdoor unit installation instructions. 42VMC Connections ENGLISH 햳 햲 햳 햴 햴 햴 햲 햳 햲 Note: Height difference / Connection length / Pipe bends: See outdoor unit installation manual. 햲 Outdoor unit 햳 Indoor unit 햴 Height difference Table II: Material supplied 햵 Photocatalytic filter 햶 Acrylic-fibre filter 햵 햷 Condensate drain pipe cover 햷 (use for horizontal installation) • Drilling template • Installation manual • Owner’s manual • Wireless infrared remote control kit 햶 Table III: Operating limits Cooling / Heating Refer to outdoor unit installation manual. Mains power supply Nominal single-phase voltage Operating voltage limits 230V ~ 50Hz min. 198V – max. 264V GB - 3 42VMC General information Unit installation Read this instruction manual thoroughly before starting the installation. • This unit complies with low-voltage (EEC/73/23) and electromagnetic compatibility (EEC/89/336) directives. • Failure to observe electric safety codes may cause a fire hazard in case of short circuits. • Inspect equipment for damage due to improper transportation or handling: file an immediate claim with the shipping company. Do not install or use damaged units. • The installation must be carried out by a qualified installer. • In case of any malfunctioning turn the unit off, disconnect the mains power supply and contact a qualified service engineer. • Follow all current national safety code requirements. In particular ensure that a properly sized and connected ground wire is in place. • This equipment contains R-410A refrigerant, a substance that is not depleting the ozone layer. • Check that voltage and frequency of the mains power supply are those required for the unit to be installed; the available power must be adequate to operate any other possible appliances connected to the same line. Also ensure that national safety code requirements have been followed for the mains supply circuit. • All of the manufacturing and packaging materials used for your new appliance are compatible with the environment and can be recycled. • The mains supply must be connected as follows: Models 42VMC 009, 012, 014: to the indoor unit. Models 42VMC 018, 024: to the outdoor unit. • This equipment contains refrigerant that must be disposed of in the proper manner. When disposing of the unit after its operational life, remove it carefully. The unit must then be delivered to an appropriate disposal centre or to the original equipment dealer, for proper environmentally friendly disposal. • Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO 1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa. Under no circumstances must sanitary type copper pipe be used. • Dispose of the packaging material in accordance with local requirements. • Use field-supplied 16 mm I.D. PVC pipe of appropriate length and with the correct thermal insulation for the condensate drain. • After installation thoroughly test the system operation and explain all system functions to the owner. • Leave this manual with the owner for consultation during future periodic maintenance. Choosing the installation site • Use this unit only for factory approved applications: the unit cannot be used in laundry or steam pressing premises. Positions to avoid: IMPORTANT: During the unit installation make first refrigerant connections and then electrical connections. When disassembling first disconnect electrical cables, then refrigerant connections. WARNING: Disconnect the mains power supply switch before servicing the system or handling any internal parts of the unit. • Exposed to direct sun. • Too close to heat sources. • On humid walls or positions with water hazard, e.g. laundry premises. • Where curtains or furniture may obstruct free air circulation. • Do not open the remote controller to avoid possible damage. In case of malfunctioning contact a qualified service engineer. Recommendations: • This installation manual describes the installation procedures of the indoor unit of a residential split system consisting of two units manufactured by Carrier. Consult factory or a qualified system engineer prior to connecting this unit to any other manufacturer's outdoor unit. Coupling units which have different control systems, may cause irreversible damage and void the warranty protection. The manufacturer declines any liability for system malfunction resulting from unapproved coupling. • Operating conditions outside the operating range (“Connections”), will cause safety device tripping or damage to unit components. • Choose an area free from obstructions which may cause irregular air distribution and/or return. • Check that the wall surface is flat enough to allow easy and safe installation. The wall structure should be strong enough to carry the unit weight and avoid deformation, rupture or vibration during operation. • Consider using an area where installation is easy. • Choose a position that allows for the clearances required (see drawing). • The manufacturer declines any liability for damage resulting from modifications or errors in the electrical or refrigerant connections. Failure to observe the installation instructions or use of the unit under conditions other than those indicated in Table III (operating limits) of the outdoor unit installation manual, will immediately void the unit warranty. GB - 4 • Look for a position in the room which assures the best possible air distribution. • Install the unit in a position where condensate can easily be piped to an appropriate drain. 42VMC Warnings: avoid… ENGLISH ...any obstruction of the unit air outlet or return. ...exposure to direct sunshine, when unit is operating in cooling mode; always use shutters or shades.. ...positions too close to heating sources which may damage the unit. ...exposure to oil vapours. ...connecting condensate piping to sewage system drain without appropriate trap. Trap height must be calculated according to the unit discharge head in order to allow sufficient and continuous water evacuation. ...installation in areas with high frequency waves. ...only partial insulation of the piping. ...installation not correctly levelled which will cause condensate dripping. ...any rise in the condensate drain piping.. ...horizontal condensate drain piping with less than 2% slope. ...flattening or kinking the refrigerant pipes or condensate pipes. ...excessive height difference between outdoor and indoor units (see installation manual of outdoor unit). ...slack on electrical connections. ...disconnecting refrigerant connections after installation: this will cause refrigerant leaks. ...unnecessary turns and bends in interconnecting tubing. ...excessive interconnecting tube length (see installation manual of outdoor unit). GB - 5 42VMC Installation Vertical wall-mounting Hole Plate Template • The preferred arrangement is generally under a window sill on an external wall. This makes it easier to install the interconnecting tubing, electrical connections and condensate pipework to the outdoor unit. The indoor unit can also be installed against an internal partition if the connections to the outdoor unit can be concealed. Ceiling installation • Using the template supplied, drill the four holes in the ceiling and position four tie rods (not supplied). • Attach the unit to the tie-rods, as shown in the illustration. • For better operation of the thermostat located on the unit, it is advisable to avoid unit installation in enclosed spaces. • There are three alternatives for the connections to the unit: parallel to the wall, through the wall or through the side. • Ensure a minimum slope of 5 mm (refrigerant connection side must be lower) by modifying on the tie-rod fixing. Preparation • Unpack the unit. C A B D • Open and remove the suction grille. To remove suction grille, remove the central lock using a pliers, then with a screwdriver remove the two side screws fixing the fasteners. • Locate the mounting template, supplied with the unit. Installation • Use the template supplied, and drill the four fixing holes in the wall. Use the four dowels provided. • Fix the attachment plate (using the two upper holes). • Attach the unit. • Fix the unit to the wall, using the two holes, positioned in the lower part. • Verify that the unit is level. GB - 6 42VMC A mm B mm C mm D mm 009 850 786 237 237 012 850 786 237 237 014 1000 940 250 285 018 1000 940 250 285 024 1000 940 250 285 42VMC Installation ENGLISH Drilling the hole in the wall for the connection of the pipes For horizontal installation To allow the condensate drain pipe to correctly come out of the unit, proceed as follows: 75 mm Ø 80 mm 50 mm 햲 Ø 70 / 80 mm 5-10 mm The pipes can exit the unit to three different directions (see illustration). For exit to the rear, the wall hole must be made in the position shown in the illustration. 햳 • Remove from suction grille, the part of grille fixed tonguing, pressing it until tabs is unhooked. 햲 Indoors 햳 Outdoors Drill a 70 or 80 mm diameter hole. The hole must have a 5-10 mm downward slope towards the outside. Insert the plastic conduit provided. Pass the electrical connecting wires through the conduit (see electrical connections). Condensate drain pipe For vertical installation Connect the PVC pipe to the connection on the drain pan. 햷 A Refrigerant connections B Condensate drain pipe A B IMPORTANT: The outdoor unit is designed to operate without the use of condensate water to cool the condenser coil. It is necessary to discharge the condensate directly into the sewer system, downpipes or to disperse it outside. Mount condensate drain pipe cover 햷 supplied, fitting it as necessary. In the event of condensate discharge pump is used (accessory), the condensate drain pipe can exit together with the refrigerant pipes. GB - 7 42VMC Refrigerant connections Make refrigerant connections before connecting the system to the power supply. Refer to the outdoor unit installation manual for tube sizing, and limitations (slopes, length, number of curves allowed, refrigerant charge, etc.) Model mm 009 012 014 018 024 9.52 12.70 12.70 12.70 12.70 Connection to the unit Insufficient tightening torque will cause gas leaks. Overtightening the fittings will damage the tube flaring and cause gas leaks. Tubing diameter Gas Liquid (Suction) (Discharge) (inches) mm (inches) (3/8”) (1/2”) (1/2”) (1/2”) (1/2”) 6.35 6.35 6.35 6.35 6.35 (1/4”) (1/4”) (1/4”) (1/4”) (1/4”) • For refrigerant tubes use seamless, insulated refrigeration grade tube, (Cu DHP type according to ISO 1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa. Under no circumstances use sanitary type copper pipe. Note: • Do not kink or flatten the tubes. • Avoid bends with a bending radius of less than 100 mm. • Do not bend copper tubes more than three times at the same point. • Do not remove flare fittings from unit tubes before actually making the connections. • Do not fasten the insulation too tightly to the tubes with straps or tape. 햴 햲 Adijustable wrench or torque wrench 햳 Connecting pipes 햴 Unit connections Tubing diameter mm (inches) 햲 햳 Torque Nm 6.35 (1/4”) 18 9.52 (3/8”) 42 12.70 (1/2”) 55 햶 Flaring the end of the tubing 햵 햵 Tube insulation 햶 Fastening tape Once all connections have been completed, check for leaks by applying soapy water to them. If incorrect connection or removal of the unit results in a refrigerant gas leak, check the refrigerant charge as indicated in the “OUTDOOR UNIT INSTALLATION MANUAL”. Remove protective caps from the copper tube ends. Position tube end downward, cut the tube to the required length and remove the burrs with a reamer. Finally wrap connections with anti-condensate insulation and tighten with tape, without exerting great pressure on the insulation. Remove flare nuts from the unit connections and place them on the tube end. Flare the tube with a flaring tool. Repair and cover any possible cracks in the insulation. L L Connection pipes and electric cables between indoor and outdoor units must be fixed to the wall with appropriate conduits. Check Flare end must not have any burrs or imperfections. The length of the flared walls must be uniform. Finger-tighten the fitting several turns, then tighten it fully with two wrenches by applying the tightening torque indicated in the table. GB - 8 Pour water into the condensate drain pan and check that it flows freely to the drain. 42VMC Electrical connections ENGLISH The mains supply must be connected as follows: Models 42VMC 009, 012, 014: to the indoor unit. Models 42VMC 018, 024: to the outdoor unit. • Make electrical connections between units prior to proceeding to mains supply unit connection. • Before proceeding with the unit connection to the mains supply locate live L and neutral N, then make connections as shown in the wiring diagram. • Ensure that mains supply connection is made through a switch that disconnects all poles, with contact gap of a least 3 mm. • The indoor - outdoor unit connecting wires must be A07 RN-F type (or higher), with synthetic rubber insulation with Neoprene coating, according to EN 60335-2-40 and HD277.S1 codes. • The mains supply connecting cable for 42VMC 009, 012, 014 units, must be H07 RN-F type (or higher), with synthetic rubber insulation with Neoprene coating, according to EN 60335-2-40 and HD277.S1 codes. • Ground connection between indoor and outdoor unit is made via the refrigerant pipes. • With the cable clamp supplied, secure the connecting cable between the two units. • Fasten the electric connecting wires with refrigerant tubes together. Allow an additional length to the electric wires for easy connection to the unit connectors. Notes: • For sizing of power supply wires and delay type fuses, refer to the outdoor unit installation instructions. • All field electrical connections are the responsibility of the installer. Jumper positioning: Units are equipped with a jumper inside the electric control box, to make them suitable for the two installation typologies: IMPORTANT: The units are provided with electronic control. A time-delay device provides a 3 minute starting delay of the compressor every time the unit is stopped or when it is initially switched on. Wall vertical installation: jumper inserted. Ceiling horizontal installation: jumper removed. To reset incorrect jumper positioning, proceed as follows: Control and safety devices • Disconnect the power supply. The following control and safety devices are built into the indoor units (see wiring diagrams): • Reposition the jumper correctly. • Connect the power supply. • Room air thermostat adjustable from 18°C to 32°C. • Motor with overheat/overcurrent protection. IMPORTANT: • Make refrigerant connections before electrical connections. When disconnecting, disconnect electrical connections before refrigerant connections. • Make ground connection prior to any other electrical connections. GB - 9 42VMC Electrical connections Cooling only 42VMC 009, 012, 014 Unit System 쐃 L N N Y O W2 230V ~ 50Hz L N N Y O W2 쐋 쐏 N Y 쐇 햳 햲 42VMC 018, 024 Unit System 쐃 C Y O W2 S R C Y O W2 S 230V ~ 50Hz R 쐋 쐏 L N R C Y 쐇 햳 Minimum connection wire size between indoor and outdoor units (mm2) Model N R C Y 42VMC 009 2.5 2.5 1.5 – – 1.5 2.5 2.5 2.5 – – 2.5 42VMC 018, 024 – – – 1.5 1.5 1.5 Earth. Live power supply. Neutral power supply. Neutral connection indoor/outdoor unit. Live connection indoor/outdoor unit. Neutral connection indoor/outdoor unit. Compressor interlocking contact. GB - 10 N 42VMC 012, 014 Terminal box legend L N N R C Y L 10 120 햲 10 100 햳 햲 Mains supply connecting cable (field wiring). 햳 Connecting cable, indoor-outdoor units (field wiring). 쐃 쐇 쐋 쐏 Indoor unit Outdoor unit Main switch Time-delay fuse or circuit breaker (see outdoor unit installation manual) 42VMC Electrical connections ENGLISH Heat pump 42VMC 009, 012, 014 Unit System 쐃 N N Y O W2 L N N Y O W2 230V ~ 50Hz L 쐋 쐏 N Y O W2 쐇 햳 햲 42VMC 018, 024 Unit System 쐃 C Y O W2 S R C Y O W2 S 230V ~ 50Hz R 쐋 쐏 L N R C Y O W2 S 쐇 햳 햳 Minimum connection wire size between indoor and outdoor units (mm2) Model L N N R C Y O W2 S 42VMC 009 2.5 2.5 1.5 – – 1.5 1.5 1.5 – 42VMC 012, 014 2.5 2.5 2.5 – – 2.5 2.5 2.5 – 42VMC 018, 024 – – – 1.5 1.5 1.5 1.5 1.5 1.5 Terminal box legend Earth. L Live power supply. N Neutral power supply. N Neutral connection indoor/outdoor unit. R Live connection indoor/outdoor unit. C Neutral connection indoor/outdoor unit. Y Compressor interlocking contact. O Reversing valve control. W2 Outdoor fan signal. S Defrost end signal. 10 120 햲 10 100 햳 햲 Mains supply connecting cable (field wiring). 햳 Connecting cable, indoor-outdoor units (field wiring). 쐃 쐇 쐋 쐏 Indoor unit Outdoor unit Main switch Time-delay fuse or circuit breaker (see outdoor unit installation manual) GB - 11 42VMC System configuration System configuration Cooling only configuration (of the remote controller) Units are factory configured as heat pumps. When a cooling only system is installed, it is necessary to change the factory configuration. Such operation must be performed by the installer as follows: Cooling only configuration (of the system) • • • • • • • • • Check all electrical connections (instructions and wiring diagram). Insert the batteries into the remote control and leave it OFF. Energise the system, turning the power supply ON. and buttons of the infrared remote control and Press the hold them pressed for more than 5 seconds. The display will be cleared, the time segments will display the first configuration item (rAdr = remote address) and the temperature segments will display the default value of this configuration item (Ab = control of both indoor units). repeatedly until “UCFG” is displayed. Press button button to change the default value (HP) Press either the or to the new value (AC). Press button to transmit the new configuration to the unit. button to leave the configuration menu. Press • Insert the batteries into the remote controller and leave it OFF. • Energize the system, turning the power supply ON. and buttons of the infrared remote control and • Press the hold them pressed for more than 5 seconds. • The display will be cleared, the temperature segments will display the first configuration item (CH = remote address) and the time segments will display the default value of this configuration item (Ab = control of both indoor units). repeatedly until “rc” is displayed. • Press button button to change the default value (HP) • Press either the or to the new value (AC). • Press button to transmit the new configuration to the unit. button to leave the configuration menu. • Press For other available configuration options, see table V. Note: When 30 seconds have elapsed and no buttons have been pressed, the remote controller will automatically exit the configuration menu and the procedure has to be restarted. For other available configuration options, see table IV. Note: When 30 seconds have elapsed and no buttons have been pressed, the remote controller will automatically exit the configuration menu and the procedure has to be restarted. Table IV Item Shown on display Explanation Description 1 “rAdr” “UAdr” “A”: remote unit A “b”: remote unit B “Ab”: remote units A and B “HP”: heat pump “AC”: cooling only 1-240 with increase of 1 4 “ZONE” 1-240 with increase of 1 5 “GFdn” 1-240 with increase of 1 6 “A St” “OF”: unit in stop mode “On”: automatic restart Remote address indoor unit A. Remote address indoor unit B. Default address is both indoor units. Default address is heat pump. Change address for cooling only. CCN unit address. Default = 1. Number of zone. Default = 0. Number of GFD. Default = 1. Choose of operating mode after a power supply interruption. 2 “UCFG” 3 Table V Shown on display “CH” “tU” “rc” “HR” “CR” “CL” Explanation Description “A”: unit A “b”: unit B “Ab”: units A and B “C”: Degrees Celsius “F”: Degrees Fahrenheit “HP”: heat pump “AC”: cooling only 17 – 32: 17°C ÷ 32°C 63 – 90: 63°F ÷ 90°F 17 – 32: 17°C ÷ 32°C 63 – 90: 63°F ÷ 90°F 12 : 12: 12 hour clock (AM/PM) 24 : 24: 24 hour clock Address indoor unit A. Address indoor unit B. Default address is both indoor units. Temperature. Default is °C. Default address is heat pump. Change address for cooling only. Heating temperature range °C min. and max. Heating temperature range °F min. and max. Cooling temperature range °C min. and max. Cooling temperature range °F min. and max. Time format (AM = morning; PM = afternoon). Default is 12 : 12. NOTE: If the selection is changed from “rc” (HP operation) to cooling only and the remote control operating mode is auto or heating, the operating mode is set to cool. GB - 12 NOTE: If the “HR” is set to a value that is lower than “CR” and the remote control operating mode is auto, the operating mode is set to cooling. 42VMC Operating test, address selector, fault code, guide for the owner and accessories ENGLISH Operating test Fault code • Perform the operating test after the units have been installed in position and the gas leak test has been completed. • Check all electrical connections (instructions and wiring diagram). • Insert the batteries into the remote control and leave it OFF. • Energise the system, turning the power supply ON. • Press the and buttons of the infrared remote control and hold them pressed for more than 5 seconds. The display will be cleared, the time segments will display the icon (Src = service test). button to leave the test • After test has been completed, press menu. Once a failure occurs with the indoor unit in operation, the green unit LED flashes at intervals of 0.5 seconds. The fault code is deduced from the number of times the green LED flashes, blocking unit operation. Between one flash cycle and the next one, a pause of 5 seconds elapses. Table VI: Fault code Code Note: When 30 seconds have elapsed and no buttons have been pressed, the remote control will automatically exit the test menu and resume its normal operation. Description 3 Room air sensor fault 4 Indoor unit coil sensor fault 6 Filter dirty 7 Outdoor unit failure 10 EEPROM corrupt 11 Unit address incomplete 12 Address / zone incomplete 13 Gas flow distributor corrupt Address selector If you are installing two indoor units in the same room and you want them to operate in independent mode, it is necessary to assign each unit its own address so that each unit can operate via its own remote control. For configuration, proceed as follows: Configuration (of the unit) • Press the and buttons of the infrared remote control and hold them pressed for more than 5 seconds. • The display will be cleared, the time segments will display the first configuration item (rAdr = remote address) and the temperature segments will display the default value of this configuration item (Ab = control of both indoor units). or button to change the default value (Ab) to • Press either the the new value (A) or (b). button to transmit the new configuration to the unit. • Press button to leave the configuration menu. • Press Guide for the owner Configuration (of the remote controller) Leave the two installation manuals for the indoor and outdoor units with the owner for future use during maintenance operations or for any other needs. • Press the and buttons of the infrared remote control and hold them pressed for more than 5 seconds. • The display will be cleared, the temperature segments will display the first configuration item (CH = remote address) and the time segments will display the default value of this configuration item (Ab = control of both indoor units). or button to change the default value (Ab) to • Press either the the new value (A) or (b). button to transmit the new configuration to the unit. • Press button to leave the configuration menu. • Press When installation and tests are completed explain the Operation and Maintenance Manual to the owner, with particular attention to the main operating modes of the air conditioner, such as: • Turning the unit on and off. • Functions of the remote control. • Removal and cleaning of the air filters. Note: When 30 seconds have elapsed and no buttons have been pressed, the remote control will automatically exit the configuration menu and the procedure has to be restarted. Table VII: Accessories 009 012 42VMC 014 42VKG9002 앬 앬 앬 앬 앬 42VKG9003 앬 앬 앬 앬 앬 Description Part number Condensate discharge pump 230V ~ 50Hz Cable cover kit 018 024 GB - 13 42VMC Air delivery and fresh air renewal Air delivery direction Wall installation, cooling Wall installation, heating Ceiling installation, cooling Ceiling installation, heating “No draught” (guide vane fully open) (position recommended for ceiling installation in cooling mode, to avoid draughts) IMPORTANT: Air is supplied into the room through the grilles located on top of the cabinet; air from the room is drawn into the unit through the grilles and filter at the bottom of the unit. Fresh air renewal Units are prearranged for introduction of renewal air through a prepunched hole located on back side. Back knockout allows connection of fresh air inlet duct. Model 009 - 012 Model 014 - 018 - 024 • Use locally purchased material, suitable for operating temperatures of 60 °C (continuous). Conduits can be of flexible polyester (with spiral core) or corrugated aluminium, externally covered with anti-condensate material (fibre glass from 12 to 25 mm thickness). GB - 14 Make absolutely sure that the above parts are not obstructed (even partially). • To complete the installation, all non-insulated ducts must be covered with anti-condensate insulation (ex. expanded neoprene, 6 mm thickness). Not observing of these instructions may cause condensate dripping; the manufacturer will not be held responsible for any damage caused. • The supplementary fan motor for outside air intake has to be supplied separately and controlled by a bipolar ON-OFF switch with safety fuses (field-installed). To adjust the fan motor air flow to the required values it is advisable to install a speed controller. Fresh air flow must be less than 10% of the total air flow, to avoid operating problems. For fresh air ventilation rates higher than 10%, a primary air treatment system with separate deflectors is recommended. • Install an air inlet grille with filter inspection port to prevent dust and dirt from entering and fouling the indoor unit heat exchanger. Filter installation also makes the installation of a duct closing damper during shutdown periods unnecessary. L010125H33 - 0402 Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1 The manufacturer reserves the right to change any product specifications without notice. Order No. 14489-74, April 2002. Supersedes Order No. 14489-74, January 2002. Printed in Italy
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2002:04:10 15:25:37 Producer : Acrobat Distiller 4.0 for Macintosh Modify Date : 2002:04:10 15:39:04+01:00 Page Count : 16EXIF Metadata provided by EXIF.tools