48GS,GX
Combination Gas Heating/
Electric Cooling Units

A Guide To Operating and Maintaining Your

Gas Heating/Electric Cooling Unit
NOTE TO INSTALLER
This manual should be left with the equipment owner.

FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.

•
•
•
•

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance
or additional information, consult a qualified installer, service agency, or the gas supplier.

Model 48GS with Standard Wire Grille

FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.

Before performing recommended maintenance,
be sure gas supply and main power switch to
unit are turned off. Electrical shock could cause
personal injury.

Model 48GX with Optional Louvered Grille

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 111
Catalog No. 534-742
Printed in U.S.A.
Form 48GS,GX-1SO
Pg 1
3-99
Replaces: 48GS-1SO
Tab 1a 6a

Your combination heating/cooling unit is equipped with
an automatic direct spark ignition and power combustion blower.

Do not attempt to light by hand; personal injury may
result.

TO LIGHT UNIT
1. Do not turn off the electrical power to unit without
first turning off the gas supply.
2. Before attempting to start the gas heating section, familiarize yourself with all the procedures that must
be followed.
If you do not follow these instructions exactly, a fire or
explosion may result, causing property damage, injury,
or loss of life.

FRONT
ACCESS
PANEL

Refer to Fig. 1. See Fig. 2 for location of gas valve. Refer
to Fig. 3 while proceeding with the following steps.

Fig. 1 — Gas Heating/Electric Cooling Unit
(Unit 48GS Shown)

Step 1 — Set the temperature selector on room thermostat to the lowest temperature setting and set system switch
to HEAT.

Step 2 — Close the external manual shutoff valve.
TO SHUT UNIT OFF

Step 3 — Turn off the electrical supply to the unit.
Step 4 — Remove the front access panel with a 5⁄16-in.
nut driver.

Do not turn off the electrical power to unit without first
turning off the gas supply.
Failure to follow these procedures can result in serious
fire or personal injury.

Step 5 — Move the selector switch on the internal gas
valve to the OFF position and wait 5 minutes.

Step 6 — Move the selector switch on the internal gas
valve to the ON position.

NOTE: If unit is being shut down because the heating season has ended, make sure to turn on power to cooling
system.
If unit is being shut down because of a malfunction, call
your dealer as soon as possible.
Should overheating occur or the gas supply fail to shut
off, shut off the manual gas valve to the unit before shutting
off the electrical supply.
Do not use this unit if any part has been under water. Immediately call a qualified service technician to inspect the
unit and to replace any part of the control system and any
gas control which has been under water.
Refer to Fig. 4 while proceeding with the following steps.

Step 7 — Replace the front access panel.
Step 8 — Turn on the electrical supply to unit.
Step 9 — Open the external manual shutoff valve.
Step 10 — Set the temperature selector on room thermostat slightly above room temperature to start unit. The induceddraft combustion-air fan will start. Main gas valve will open
and main burners should ignite within 5 seconds. If the burner
does not light within 5 seconds, the ignition module will go
into a Retry mode after a period of approximately 22 seconds (following the 5-second ignition period).
If the burners do not light within 15 minutes of the initial
call for heat, there is a lockout.

Step 1 — Set the temperature selector on room thermostat to lowest temperature setting and set system switch to
OFF.

Step 11 — Set the temperature selector on room thermostat to desired setting.

Step 2 — Close the external manual shutoff valve.
Step 3 — Turn off the electrical power supply to the unit.

1. If the main burners fail to light, or the blower fails
to start, shut down gas heating section and call your
dealer for service.
2. Never attempt to manually light the main burners on
unit with a match, lighter, or any other flame. If the
electric sparking device fails to light the main burners, refer to the following shutdown procedures, then
call your dealer as soon as possible.
Failure to follow these requirements could result in serious
personal injury.

Step 4 — Remove the front access panel.
Step 5 — Move the selector switch on the internal gas
valve to the OFF position.
Step 6 — Replace the burner access panel.
Step 7 — Restore electrical power to the unit and set system switch to COOL to ensure operation of the cooling system during the cooling season.
2

ROUTINE MAINTENANCE
All routine maintenance should be handled by skilled, experienced personnel. Your dealer can help you establish a
standard procedure.
For your safety, keep the unit area clear and free of combustible materials, gasoline, and other flammable liquids and
vapors.
To assure proper functioning of the unit, flow of combustion and ventilating air must not be obstructed from reaching
the unit. Clearance of at least 30 in. is required on all sides
except the duct side.

Never operate your unit without filters in place. Failure
to heed this warning may result in damage to the blower
motor and/or compressor. An accumulation of dust and
lint on internal parts of your unit can cause loss of efficiency and, in some cases, fire.

Heat Exchanger — To ensure dependable and efficient
heating operation, the heat exchanger should be checked by
a qualified maintenance person before each heating season,
and cleaned when necessary. This checkout should not be
attempted by anyone not having the required expertise and
equipment to properly do the job. Checking and/or cleaning
the heat exchanger involves removing the gas controls assembly and the flue collector box cover and, when completed, reinstalling the gas controls assembly for proper operation. Also, the flue collector box cover must be replaced
correctly so that a proper seal is maintained. Contact your
dealer for the required periodic maintenance.

MAINTENANCE AND CARE FOR THE
EQUIPMENT OWNER
Before proceeding with those things you might want to
maintain yourself, please carefully consider the following:

Fans and Fan Motor — Periodically check the condition of fan wheels and housings and fan-motor shaft
bearings. No lubrication of condenser- or evaporator-fan
bearings or motors is required or recommended.

1. TURN OFF GAS SUPPLY AND ELECTRICAL
POWER TO YOUR UNIT BEFORE SERVICING
OR PERFORMING MAINTENANCE.
2. Do not turn off electrical power to this unit without
first turning off the gas supply.
3. When removing access panels or performing maintenance functions inside your unit, be aware of sharp
sheet metal parts and screws. Although special care
is taken to reduce sharp edges to a minimum, be extremely careful when handling parts or reaching into
the unit.

Evaporator and Condenser Coils — Cleaning of
the coils should only be done by qualified service personnel. Contact your dealer for the required annual
maintenance.
Condensate Drain — The drain pan and condensate
drain line should be checked and cleaned at the same time
the cooling coils are checked by your dealer.

Compressor — All compressors are factory-shipped with
a normal charge of the correct type refrigeration grade oil in
them and should rarely require additional oil. The service
person must be certain the proper oil level is maintained in
the compressor when it is installed and running.

Air Filters — Air filter(s) should be checked at least every 3 or 4 weeks and changed or cleaned whenever it becomes dirty. Dirty filters produce excessive stress on the blower
motor and can cause the motor to overheat and shut down.
Table 1 indicates the correct filter size for your unit. Refer
to Fig. 5 to access the filter(s).
To replace or inspect filter(s) (or accessory filter rack when
supplied):
1. Remove the filter access panel using a 5⁄16-in. nut driver.
2. Remove the filter(s) by pulling the filter(s) out of the unit.
If the filter(s) is dirty, clean or replace with new one.
When installing the new filter(s), note the direction of the
airflow arrows on the filter frame.
If you have difficulty in locating your air filter(s), or if
you have questions concerning proper filter maintenance, contact your dealer for instructions. When replacing filters, always use the same size and type of filter that was supplied
originally by the installer.

Condenser Fan
Do not poke sticks, screwdrivers, or any other object
into revolving fan blades. Severe bodily injury may
result.
The fan must be kept free of all obstructions to ensure proper cooling. Contact your dealer for any required
service.

Table 1 — Indoor-Air Filter Data*
UNIT SIZE
48GS018-030
48GS036-042
48GS048-060
48GX024-030
48GX036
48GX042-060

FILTER SIZE
20x20
20x24
24x30
20x20
20x24
24x30

*For filter grille installations only.

Fig. 2 — Gas Heating/Electric Cooling Unit
3

STEP 1

STEP 2

STEP 3

STEP 5

STEP 4

STEP 7

STEP 6

STEP 8

STEP 10

STEP 9

Fig. 3 — To Light Unit
4

STEP 1

STEP 2

STEP 3

STEP 5

STEP 4

STEP 6

STEP 7

Fig. 4 — To Shut Unit Off

5

Components in heat section may be hot after unit
has been started up. When observing flame, be careful not to get close to or touch heating components
or serious personal injury may result.
Watch the burner flame to see if it is bright blue. If you
observe a suspected malfunction or if the burner flames
are not bright blue, call your dealer.
6. Replace burner access panel.

Unit Panels — After performing any maintenance or service on the unit, be sure all panels are fastened securely in
place to prevent rain from entering unit cabinet and to prevent disruption of the correct unit airflow pattern.
ACCESS PANEL
FILTER ACCESS
PANEL*

REGULAR DEALER MAINTENANCE

*For accessory filter rack.

In addition to the type of routine maintenance you might
be willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection
(preferably each year, but at least every other year) should
include the following:
1. Inspection of all flue product passages — including the
burners, heat exchanger, and flue collector box.
2. Inspection of all combustion- and ventilation-air passages and openings.
3. Close inspection of all gas pipes leading to and inside of
your unit.
4. Inspection and, if required, cleaning of the condenser
and evaporator coils.
5. Inspection and, if required, cleaning of the evaporator
drain pan.
6. Inspection and cleaning of blower wheel housing and
motor.
7. Inspection of all supply-air and return-air ducts for leaks,
obstructions, and insulation integrity. Any problems found
should be resolved at this time.
8. Inspection of the unit base to ensure that no cracks, gaps,
etc., exist which may cause a hazardous condition.
9. Inspection of the unit casing for signs of deterioration.
10. Inspection of all electrical wiring and components to assure proper connection.
11. Inspection for leaks in the refrigerant circuit. Pressurecheck to determine appropriate refrigerant charge.
12. Inspection of compressor oil level.
13. Operational check of the unit to determine working conditions. Repair or adjustment should be made at this time.
Your servicing dealer may offer an economical service contract that covers seasonal inspections. Ask for further
details.
Complete service instructions can be found in the unit
Installation, Start-Up and Service Instructions.

Fig. 5 — Filter Access Panel — Vertical Supply Shown

Electrical Controls and Wiring — Electrical controls are difficult to check without proper instrumentation;
therefore, if there are any discrepancies in the operating cycle,
contact your dealer and request service.
Refrigerant Circuit — The refrigerant circuit is difficult to check for leaks without the proper equipment; therefore, if inadequate cooling is suspected, contact your local
dealer for service.

Combustion Area and Vent System — The combustion area and vent system should be inspected visually
before each heating season. The normal accumulation of dirt,
soot, rust, and scale can result in loss of efficiency and improper performance if allowed to build up.

If your unit makes an especially loud noise when the
main burners are ignited, shut down the heating section
and call your dealer.
Proceed as follows to inspect the combustion area and powerventing system of your unit.
1. Turn off electrical power and gas supply to your unit.
2. Remove burner access panel. (See Fig. 1.)
3. Using a flashlight, carefully inspect the burner areas for
dirt, soot, rust, or scale. See Fig. 2.

If dirt, soot, rust, or scale accumulations are found,
call your dealer and do not operate your heating section.

WARRANTIES

4. When you have completed your inspection, follow the
start-up procedures in this manual to restore your unit to
operation.
5. Observe unit heating operation.

Units 48GS and GX have warranties located at the back
of this book. Be sure to read the warranty carefully to determine the coverage for your unit.
6

BEFORE YOU CALL FOR SERVICE,
CHECK FOR SEVERAL EASILY-SOLVED
PROBLEMS

NOTE: Before proceeding with the next check, turn OFF
the gas supply, then the electrical power supply to the unit.
Remove the control access door.

If insufficient heating or cooling is suspected:

( ) During the heating season, check the control dial on the
internal gas valve. Is it in the ON position? If it is not, be
sure it was not turned off for the purpose of safety. If no
safety hazards exist, follow the start-up procedures in this
manual.

( ) Check for sufficient airflow. Check the air filter for dirt.
Check for blocked return-air or supply-air grilles. Be sure
they are open and unobstructed. If these checks do not reveal the cause, call your servicing dealer.

( ) If your unit still fails to operate, call your servicing dealer
for troubleshooting and repairs. Specify the model and serial
numbers of your unit. (Record them in this manual in the
space provided.) If the dealer knows exactly which unit you
have, he may be able to offer suggestions over the phone, or
save valuable time through knowledgeable preparation for
the service call.

If your unit is not operating at all, check the following list
for easy solutions:
( ) Check to be sure that your thermostat temperature selector is set above the indoor temperature during the heating
season, or below the indoor temperature during the cooling
season. Be sure the system switch is in the proper HEAT or
COOL position and not in the OFF position.

IN CASE OF TROUBLE

( ) Is the electrical supply switch ON? Are any fuses blown,
or has the circuit breaker tripped?

If after performing the above and unit performance is still
unsatisfactory, shut off the unit and call your dealer.

( ) During the heating season, check the external manual
shutoff valve. Is this lever parallel with the pipe, indicating
that the valve is open? Or is the lever at a right angle,
indicating that the valve is closed? If closed, has the gas been
shut off for safety reasons? Otherwise, you may open the
valve and follow the start-up procedures listed in this manual.

Dealer’s Name
Telephone
Unit Model
Unit Serial Number

7

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CUT ALONG DOTTED LINE
CUT ALONG DOTTED LINE

9

10

MODEL 48GS WARRANTY

11

MODEL 48GX WARRANTY

Copyright 1999 Carrier Corporation
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 111
Catalog No. 534-742
Printed in U.S.A.
Form 48GS,GX-1SO
Pg 12
3-99
Replaces: 48GS-1SO
Tab 1a 6a



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Create Date                     : 1999:03:10 11:46:49Z
Modify Date                     : 2005:11:11 18:39:08-05:00
Metadata Date                   : 2005:11:11 18:39:08-05:00
Producer                        : Acrobat Distiller 3.0 for Windows
Keywords                        : 
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : Carrier Corporation
Subject                         : 
Document ID                     : uuid:26b0abf7-38e7-4cf0-9b3d-da51d49e1984
Instance ID                     : uuid:d86ea72d-a385-48cf-b8b7-78e3046824d5
Page Count                      : 12
Author                          : Carrier Corporation
EXIF Metadata provided by EXIF.tools

Navigation menu