Carrier 48Vg A Owners Manual OM48VG 02
2015-03-30
: Carrier Carrier-48Vg-A-Owners-Manual-678501 carrier-48vg-a-owners-manual-678501 carrier pdf
Open the PDF directly: View PDF .
Page Count: 8
1
48VG---A and 48VG---B
Performance™ 15 and 16 SEER
2---Stage Packaged Air Conditioner and Gas Furnace
System With Puronr(R---410A) Refrigerant
Single and Three Phase
2 --- 5 N o m i n a l To n s ( S i z e s 2 4 --- 6 0 )
Owner’s Information Manual
A09033
Fig. 1 -- Unit 48VG--A, 48VG--B
NOTE TO EQUIPMENT OWNER:
For your convenience, please record the model and serial numbers of your new equipment in the spaces
provided. This information, along with the installation data and dealer contact information, will be helpful
should your system require maintenance or service.
UNIT INFORMATION
Model # _____________________________________
Serial # ______________________________________
ACCESSORIES (List type of model #)
_____________________________________________
_____________________________________________
_____________________________________________
INSTALLATION INFORMATION
Date Installed________________________________
DEALERSHIP CONTACT INFORMATION
Company Name_______________________________
Address______________________________________
_____________________________________________
Phone Number _______________________________
Technician Name _____________________________
_____________________________________________
NOTE TO INSTALLER:
This manual must be left with the equipment owner.
2
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit. consult local
building codes, the current editions of the National Fuel Gas Code
(NFGC) NFPA 54/ANSI Z223.1, and the National Electrical Code
(NEC) NFPA 70.
In Canada refer to the current editions of the National Standards of
Canada CAN/CSA--B149.1 and .2 Natural Gas and Propane
Installation codes, and Canadian Electrical Code CSA C22.1
Recognize safety information. This is the safety--alert symbol .
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury. Understand
these signal words: DANGER, WARNING, and CAUTION. These
words are used with the safety--alert symbol. DANGER identifies
the most serious hazards which will result in severe personal injury
or death. WARNING signifies hazards which could result in
personal injury or death. CAUTION is used to identify unsafe
practices which may result in minor personal injury or product and
property damage. NOTE is used to highlight suggestions which
will result in enhanced installation, reliability, or operation.
NOTE: Installer: This manual should be left with the equipment
user.
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Installation and servicing of this equipment can be
hazardous due to mechanical and electrical components.
Only trained and qualified personnel should install, repair,
or service this equipment.
!WARNING
FIRE, EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury, death, and/or property damage.
Do not store or use combustible materials, gasoline, or other
flammable vapors and liquids in the vicinity of this or any
other appliance.
!WARNING
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Do not use this unit if any part has been under water.
Immediately call a qualified service technician to inspect the
unit and to replace any part of the control system which has
been under water.
!WARNING
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury, death and/or property damage.
What to do if you smell gas:
1. Do not try to light any appliance.
2. Do not touch any electrical switch; do not use any phone
in your building.
3. Leave the building immediately.
4. Immediately call your gas supplier from a nearby phone.
Follow the gas supplier’s instructions.
5. If you cannot reach your gas supplier, call the fire
department.
!WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury and/or death.
Before performing recommended maintenance, be sure the
main power switch to unit is turned off and lock--out tag is
installed. There may be more than one disconnect switch.
!WARNING
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal
injury, death and/or property damage.
1. Do not turn off the electrical power to unit without first
turning off the gas supply.
2. Before attempting to start the gas heating section,
familiarize yourself with all the procedures that must be
followed.
!WARNING
FIRE, EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury, death, and/or property damage.
Do not attempt to light by hand. Never attempt to manually
light the main burners on unit with a match, lighter, or any
other flame. If the electric sparking device fails to light the
main burners, refer to the following shutdown procedures,
then call your dealer as soon as possible.
!WARNING
CUT HAZARD
Failure to follow this caution may result in personal injury.
When removing access panels or performing maintenance
functions inside your unit, be aware of sharp sheet metal
parts and screws. Although special care is taken to reduce
sharp edges to a minimum, be extremely careful and wear
appropriate protective clothing, safety glasses and gloves
when handling parts or reaching into the unit.
!CAUTION
3
UNIT INTRODUCTION
This unit is a small packaged gas heat/electric cooling system that
utilizes the comfort of gas heating packaged along with efficient
electric air conditioning. This unit uses Puronr, the ozone
friendly refrigerant for cooling.
Starting or Shutting Off Unit
NOTE: Your combination heating/cooling unit is equipped with
an automatic direct spark ignition and power combustion blower.
To start unit gas heat:
Refer to Fig. 2 for location of unit front access panel. Refer to Fig.
3 for location of gas valve. Refer to Fig. 4 while proceeding with
the following steps.
1. Set the temperature selector on room thermostat to the low-
est temperature setting and set system switch to HEAT.
2. Close the external manual gas shutoff valve.
3. Turn off the electrical supply to the unit.
4. Remove the control access panel with a 5/16--in. nut driver.
(See Fig. 2.)
Compressor
Access Panel
Control
Access
Panel
Blower
Access
Panel
Filter Access Panel
For Accessory FIlter
Rack
A14456
Fig. 2 -- Unit Access Panel
5. Move the selector switch on the internal gas valve to the
OFF position and wait 5 minutes.
6. Move the selector switch on the internal gas valve to the ON
position.
7. Replace the control access panel.
8. Turn on the electrical supply to unit.
9. Open the external manual gas shutoff valve.
10. Set the temperature selector on room thermostat slightly
above room temperature to start unit. The induced--draft
combustion air fan will start. Main gas valve will open and
main burners should ignite within 25 seconds. If the burner
does not light within 25 seconds, the ignition module will
go into a Retry Mode after a period of approximately 20
seconds (following the 7--second ignition period). If the
burners do not light by the 4th ignition try of the initial call
for heat, there is a lockout.
11. Set the temperature selector on room thermostat to desired
setting.
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury, death, and/or property damage.
1. If the main burners fail to light, or the blower fails to
start, shut down gas heating section and call your dealer for
service.
2. Never attempt to manually light the main burners on unit
with a match, lighter, or any other flame. If the electric
sparking device fails to light the main burners, refer to the
following shutdown procedures, then call your dealer as
soon as possible.
!WARNING
Burners Gas Valve
Flue Hood
A14490
Fig. 3 -- Gas Heating/Electric Cooling Unit with Access Panel
Removed
To shut off unit gas heat:
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal
injury, death, and/or property damage.
Do not turn off the electrical power to unit without first
turning off the gas supply.
!WARNING
NOTE: If the unit is being shut down because of a malfunction,
call your dealer as soon as possible.
Should overheating occur or the gas supply fail to shut off, shut
off the external manual gas valve to the unit before shutting off
the electrical supply. Do not use this unit if any part has been under
water. Immediately call a qualified service technician to inspect the
unit and to replace any part of the control system and any gas
control which has been under water.
Refer to Fig. 5 while proceeding with the following steps.
1. Set the temperature selector on room thermostat to lowest
temperature setting and set system SWITCH to OFF.
2. Close the external manual shutoff valve.
3. Turn off the electrical power supply to the unit.
4. Remove the control access panel. (See Fig. 2.)
5. Move the selector switch on the internal gas valve to the
OFF position.
6. Replace the control access panel.
4
To start unit electric cooling:
Refer to Fig. 6 while proceeding with the following steps.
1. Set the temperature selector on room thermostat to highest
temperature setting and set system SWITCH to OFF.
2. Close the external manual shutoff valve, if not already
closed.
3. Turn ON the electrical power supply to the unit.
4. Set system switch to COOL.
5. Set the temperature selector on room thermostat slightly be-
low the room temperature to start unit.
To shut off unit electric cooling:
Refer to Fig. 7 while proceeding with the following steps.
1. Set the temperature selector on room thermostat to highest
temperature setting and set system SWITCH to OFF.
2. Close the external manual shutoff valve, if not already
closed.
3. Turn off the electrical power supply to the unit.
OPERATING YOUR UNIT
The operation of your unit is controlled by the indoor temperature
control (thermostat). You simply adjust the thermostat and it
maintains the indoor temperature at the level you select. Most
thermostats of heating and cooling systems have 3 controls: a
temperature control selector, a FAN control, and a SYSTEM or
MODE control. Refer to your thermostat owner’s manual for more
information.
To better protect your investment and to eliminate unnecessary
service calls, familiarize yourself with the following facts:
Cooling Mode
With the SYSTEM control set to COOL, your unit will run in
cooling mode until the indoor temperature is lowered to the level
you have selected. On extremely hot days, your unit will run for
longer periods at a time and have shorter “off” periods than on
moderate days.
Gas Heat Mode
With the SYSTEM or MODE control of your indoor thermostat set
to HEAT, your unit will run in heating mode until room
temperature is raised to the level you have selected. On cold days
and nights, your system will typically run for longer periods of
time and have shorter “off” periods than on moderate days.
MAINTENANCE AND SERVICE
This section discusses maintenance that should be performed on
your system. Most maintenance should be performed by your
dealer. You, as the owner, may wish to handle some minor
maintenance for your new unit.
Routine Maintenance
All routine maintenance should be handled by skilled, experienced
personnel. Your dealer can help you establish a standard procedure.
For your safety, keep the unit area clear and free of combustible
materials, gasoline, and other flammable liquids and vapors.
To assure proper functioning of the unit, flow of condenser air
must not be obstructed from reaching the unit. Clearance from the
top of the unit is 48 in. (1219 mm). Clearance of at least 36 in.
(914 mm) is required on sides except the power entry side (42 in.
(1067 mm) clearance) and the duct side (12 in. (305 mm)
minimum clearance). Also, ensure that the return--air duct
connection (s) is physically sound, is sealed to the furnace casing,
and terminates outside the space containing the furnace.
Maintenance and Care for the Equipment Owner
Before performing equipment maintenance yourself, please
carefully consider the following:
FIRE, EXPLOSION, ELECTRICAL SHOCK AND
CUT HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
1. Turn off gas supply first, then all electrical power to your
unit and install lock--out tag before servicing or per-
forming maintenance.
2. When removing access panels or performing
maintenance functions inside your unit, be aware of
sharp sheet metal parts and screws. Although special care
is taken to reduce sharp edges to a minimum, be
extremely careful when handling parts or reaching into
the unit. Wear safety glasses, gloves, and appropriate
protective clothing.
!WARNING
Air Filters
UNIT OPERATION HAZARD
Failure to follow this caution may result in property
damage.
Never operate your unit without filters in place. An
accumulation of dust and lint on internal parts of your unit
can cause loss of efficiency and blower motor and/or
compressor damage.
!CAUTION
The air filter(s) should be checked every 3 or 4 weeks and
changed or cleaned whenever it becomes dirty. Dirty filters
produce excessive stress on the blower motor and can cause the
motor to overheat and shut down.
This unit must have air filters in place before it can be operated.
These filters can be located in one of at least two places. In many
applications, the installer will provide return air filter grilles
mounted on the wall or ceiling of the conditioned structure. In the
instance of filter grilles, the filters can simply be removed from the
grille and replaced.
The other typical application is an accessory filter rack installed
inside the unit itself. The following information is given to assist in
changing filters used in these internal filter racks.
Filter kits are available as a purchased accessory or a factory
installed option. The same filter kit is included with the accessory
economizers and factory installed economizers.
Table 1 – Indoor Air Filter Data
Unit Size Filter Size in. (mm)
24-040/060 2each20x12x1
(508 x 305 x 25 mm)
30-040/060 2each20x12x1
(508 x 305 x 25 mm)
36-060/090 1 each 24 x 14 x 1 (610 x 406 x 25),
24 x 16 x 1 (610 x 406 x 25)
42-060/090 1 each 24 x 14 x 1 (610 x 356 x 25),
24 x 16 x 1 (610 x 406 x 25)
48-090/115/130* 1 each 24 x 16 x 1 (610 x 406 x 25),
24 x 18 x 1 (610 x 457 x 25)
60-090/115/130* 1 each 24 x 16 x 1 (610 x 406 x 25),
24 x 18 x 1 (610 x 457 x 25)
*Units with bent indoor coil.
5
55
STEP 1 STEP 2
C
L
O
S
E
STEP 3
OFF
ON
MAIN
STEP 4
STEP 7
OFF
ON
MAIN
STEP 8
STEP 5
(460 VAC MODELS)
72
STEP 10
STEP 6
(460 VAC MODELS)
STEP 9
O
P
E
N
STEP 5
(208/230 VAC MODELS)
STEP 6
(208/230 VAC MODELS)
A13035
Fig. 4 -- To Start Unit Gas Heat
6
55
STEP 1 STEP 2
C
L
O
S
E
STEP 3
OFF
ON
MAIN
STEP 4
STEP 6
STEP 5
(460 VAC MODELS)
STEP 5
(208/230 VAC MODELS)
A13036
Fig. 5 -- To Shut--off Unit Gas Heat
90
STEP 1 STEP 2
C
L
O
S
E
72
STEP 4 & 5
OFF
ON
MAIN
STEP 3
A09194
Fig. 6 -- To Start Unit Electric Cooling
7
90
STEP 1 STEP 2
C
L
O
S
E
STEP 3
OFF
ON
MAIN
A07797
Fig. 7 -- To Shut--off Unit Electric Cooling
To replace or inspect filters in accessory filter rack (See Fig. 2):
1. Remove the filter access panel using a 5/16--in. nut driver.
2. Remove the filter(s) by pulling it out of the unit. If the
filter(s) is dirty, clean or replace with a new one.
When installing the new filter(s), note the direction of the airflow
arrows on the filter frame which should be pointing at the indoor
coil.
3. Reinstall filter access panel ensuring opening is air and
water tight.
If you have difficulty locating your air filter(s) or have questions
concerning proper filter maintenance, contact your dealer for
instructions. When replacing filters, always use the same size and
type of filter that was supplied originally by the installer. See Table
1 for filter sizes supplied with accessory filter rack.
Fans and Fan Motors
Periodically check the condition of fan wheels and housings and
fan motor shaft bearings. Contact your dealer for the required
annual maintenance.
Heat Exchanger
To ensure dependable and efficient heating operation, the heat
exchanger should be checked by a qualified maintenance person
before each heating season, and cleaned when necessary. This
checkout should not be attempted by anyone not having the
required expertise and equipment to properly do the job. Contact
your dealer for the required periodic maintenance.
Indoor and Outdoor Coils
Cleaning of the coils should only be done by qualified service
personnel. Contact your dealer for the required annual
maintenance.
Condensate Drain
The drain pan and condensate drain line should be checked and
cleaned at the same time the cooling coils are checked by your
dealer.
Compressor
All compressors are factory shipped with a normal charge of the
correct type of refrigeration grade oil. A compressor should rarely
require additional oil.
Condenser (Outdoor) Fan
PERSONAL INJURY AND UNIT DAMAGE
HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Do not insert sticks, screwdrivers, or any other objects into
revolving fan blades.
!WARNING
The fan must be kept free of all obstructions to ensure proper
cooling. Contact your dealer for any required service.
Electrical Controls and Wiring
Electrical controls are difficult to check without proper
instrumentation. If there are any discrepancies in the operating
cycle, contact your local dealer and request service.
Refrigerant Circuit
The refrigerant circuit is difficult to check for leaks without the
proper equipment. If inadequate cooling is suspected, contact your
local dealer for service.
EXPLOSION AND ENVIRONMENTAL HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
System under pressure. Relieve pressure and recover all
refrigerant before system repair or final unit disposal. Use
all service ports and open all flow--control devices,
including solenoid valves.
!WARNING
Unit Panels
After performing any maintenance or service on the unit, be sure
all panels are fastened securely in place to prevent rain from
entering unit cabinet and to prevent disruption of the correct unit
airflow pattern.
Combustion Area and Vent System
For proper and safe operation, the furnace needs air for combustion
and ventilation. The air openings, on the furnace, the air openings
to the area in which the furnace is installed, and the spacing around
the furnace must not be blocked or obstructed.
The combustion area and vent system should be inspected visually
before each heating season. The normal accumulation of dirt, soot,
rust, and scale can result in loss of efficiency and improper
performance if allowed to build up. This inspection should be done
by a trained service person.
8
FIRE, EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury, death and/or property damage.
If your unit makes an especially loud noise when the main
burners are ignited, shut down the heating section and call
your dealer.
!WARNING
BURN HAZARD
Failure to follow this caution may result in personal injury.
Components in heating section may be hot after unit has
been started up. When observing flame, be careful not to get
close to or touch heating components.
!CAUTION
Regular Dealer Maintenance
In addition to the type of routine maintenance you might be willing
to perform, your unit should be inspected regularly by a properly
trained service technician. An inspection (preferably each year, but
at least every other year) should include the following:
1. Inspection of all flue product passages--including the burn-
ers, heat exchanger, and flue collector box, Mare sure the
burner flames are blue in color and in proper adjustment.
Refer to Fig. 8 for burner flame.
MANIFOLD
BURNER
BURNER FLAME
C99021
Fig. 8 -- Monoport Burner
2. Inspection of all combustion--and ventilation--air passages
and openings.
3. Close inspection of all gas pipes leading to and inside of
your unit.
4. Inspection and, if required, cleaning of the outdoor and
indoor coils.
5. Inspection and, if required, cleaning of the indoor coil con-
densate drain pan.
6. Inspection and cleaning of blower wheel housing and
motor.
7. Inspection of all supply--air and return--air ducts for leaks,
obstructions, and insulation integrity. Any problems found
should be resolved at this time.
8. Inspection of the unit base to ensure that no cracks, gaps,
etc., exist which may cause a hazardous condition.
9. Inspection of the unit casing for signs of deterioration.
10. Inspection of all electrical wiring and components to assure
proper connection.
11. Inspection for leaks in the refrigerant circuit. Pressure
check to determine appropriate refrigerant charge.
12. Operational check of the unit to determine working
conditions. Repair or adjustment should be made at this
time.
Your servicing dealer may offer an economical service contract that
covers seasonal inspections. Ask for further details.
Complete service instructions can be found in the unit Installation,
Start--up and Service Instructions.
Warranty Certificate
Your unit has a limited warranty. Be sure to read the warranty
carefully to determine the coverage for your unit.
Before you call for service...
...check for several easily--solved problems.
If insufficient heating or cooling is suspected:
( ) Check for sufficient airflow. Check the air filter for dirt. Check
for blocked return--air or supply--air grilles. Be sure they are open
and unobstructed. If these checks do not reveal the cause, call your
servicing dealer.
If your unit is not operating at all, check the following list for
easy solutions:
( ) Check to be sure that your thermostat temperature selector is
set below the indoor temperature during the cooling season or
above the indoor temperature during heating season. Be sure the
SYSTEM switch or MODE control is in the COOL or HEAT
position and not in the OFF position.
( ) If your unit still fails to operate, call your servicing dealer for
troubleshooting and repairs. Specify the model and serial numbers
of your unit. (Record them in this manual in the space provided.) If
the dealer knows exactly which unit you have, he may be able to
offer suggestions over the phone, or save valuable time through
knowledgeable preparation for the service call.
In Case of Trouble
If you perform the steps above and unit performance is still
unsatisfactory, shut off the unit and call your dealer.
Copyright 2014 Carrier Corp. S7310 W. Morris St. SIndianapolis, IN 46231 Edition Date: 10/14
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No: OM48VG---02
Replaces: OM48VG---01