50TFF-4SB

50TFF004-014
SINGLE-PACKAGE ELECTRIC
COOLING UNITS WITH
FIELD-INSTALLED ELECTRIC HEAT
—
—
—

PERFORMANCE DATA
CERTIFIED DIMENSION PRINTS
CERTIFIED ROOF CURB
DIMENSION PRINTS

© Copyright 2005 Carrier Corporation • Syracuse, New York 13221
Form 50TFF-4SB

Replaces: 50TFF-3SB

Printed in U.S.A.

11-05

Catalog No. 04-51500003-01

Date:

50TFF004-014
SINGLE-PACKAGE ELECTRIC
COOLING UNITS WITH
FIELD-INSTALLED ELECTRIC HEAT

Supersedes:

JOB NAME:

LOCATION:

BUYER:

BUYER P.O. #

UNIT NUMBER:

MODEL NUMBER:

50TFF

Rev.:
-4SB

CARRIER #

UNIT DESIGNATION:
PERFORMANCE DATA CERTIFIED BY:

DATE:
DESCRIPTION

Units are a single piece, electric cooling unit, with a low profile, pre-wired, tested and charged at the factory.
The units have the capability for convertible supply and return openings and are intended for installation on an
accessory curb (ordered separately), or for slab mounting (for horizontal duct connections). Units are designed
to accept a field-installed economizer, enthalpy control, manual or two-position outside-air damper, roof curb,
as well as many choices of field-installed electric heat. Refer to accessory chart below for full listing.

FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•

Standard one-year full product warranty.
Five-year protection plan for the motor-compressor.
Outdoor ambient cooling operation from 25 F (–4 C) to 115 F (46 C).
Units are tested and certified by ARI and certified by UL and CSA.
Factory-run test printout included in each rooftop.
24-volt control circuit, with resettable breaker.
Two-inch disposable-type return air filters in dedicated rack.
Hermetic compressor on independent circuit with internal line break and
overload protection, self-lubricating with internal discharge muffler.
Scroll compressor with internal overload protection (50TFF007 and
50TFF014).
Each refrigerant circuit contains a filter drier to trap dirt and particles.
Single compressor on 3 to 6 ton units.
Dual compressors on 71/2 to 121/2 ton units.
Two-speed direct drive evaporator fan on all units except size 007 which
is belt driven. Adjustable belt drive fans are optional on all sizes.
Non-corrosive condensate pan with self-draining sloping design with
both bottom and side drain connections.

• Thru-the-bottom power control entry capability.
• Evaporator and condenser coils constructed of aluminum fins mechanically bonded to seamless copper tubes.
• Single point electrical connections.
• Direct-drive propeller condenser fan totally enclosed with permanently
lubricated bearings.
• Pre-painted, insulated cabinet with primer inner panels, certified 500-hr
salt spray test and non-corrosive screws.
• Large, easily removable panels provide ready access to unit components
for rapid removal or maintenance.
• Filter access door for filter access and maintenance that requires no tools.
• Fixed orifice metering device precisely controls refrigerant flow to each
circuit individually.
• Reliable accurate control circuit with color coded wires and easy accessible terminal board.
• Loss of charge, freeze protection, and high pressure switches standard.
• Cooling units with field-installed electric heat with accessory singlepoint electrical kit have single-point electrical power connection — UL
approved.

PERFORMANCE DATA
COOLING
Net Total Cap. _____________________________________________ Btuh
Net Sensible Cap. __________________________________________ Btuh
Compressor Power Input _____________________________________ kW
_______________________________________ F Outdoor Air Temperature
Indoor Entering Air db _______________ F wb _________________ F
Cfm ___________________ Ext. Static Pressure ______________ in. wg
EER _________________________________________________________

HEATING
Heating Capacity
kW ________________________________________________________
Btuh _______________________________________________________
OPERATING WEIGHT _________

lb (unit) _____________lb (curb)

ELECTRICAL DATA
Power Supply to Unit _____________

Volts _________________ Phase ___________________ Hz

Minimum Circuit Amps ________________

2

Maximum Overcurrent Protection (Fuse only)____________

OPTIONS AND ACCESSORIES
FACTORY-INSTALLED OPTIONS

 EconoMi$er IV with Controller
 EconoMi$er2 with 4-20 mA Actuator Only




(PremierLink™ or 3rd Party EMS System
Control)
Copper/Copper Coils — Evaporator,
Condenser, Both
Pre-Coated Condenser Coil
E-Coat (Post-Coated) Condenser Coil

 Non-Fused Disconnect Switch (factory wired)
 115-Volt Convenience Outlet (factory wired, load side)
 PremierLink Control
 25% Manual Air Damper
 Alternate Motor and Drive
(except 007 and 009 size)
 High-Static Motor (except size 014)
 Novar 3051 Control

CUT ALONG DOTTED LINE

FIELD-INSTALLED ACCESSORIES

 EconoMi$er IV with Controller
 EconoMi$er2 with 4-20 mA Actuator and No Microprocessor — Vertical or Horizontal
 25% Open Two-Position Damper
 25% Open Manual Air Damper
 50% Open Manual Outdoor Air Damper
 100% Open Two-Position Damper
 Outdoor Air/Return Air Temperature
Sensor
 Outdoor Air/Return Air Enthalpy Sensor
 Roof Curb (14 or 24-in. Height)
 Thru-the-Bottom/Roof Curb Electrical
Connection Kit
 Time Guard II Compressor Anti-Cycle Control
 Condenser Coil Hail Guard
 Condenser Coil Grille
 Room Temperature Sensor

BLANKET QUOTE CONTROLS
115-Volt Field Powered GFI Convenience Outlet
(line side)
115-Volt GFI Convenience Outlet (field powered)
E-Coated Aluminum/Copper Condenser and Evaporator Coils
Fused Disconnect
Hinged Acess Panels
Lockout of High Fire Stage for Heating








Low Ambient Controller (Motormaster® I)
Smoke Detector — Return Air
Smoke Detector — Return and Supply Air
Smoke Detector — Supply Air
Split Power (transfer switch NOT included)
UV-C Lamps (installed and powered with door interlock
switch and disconnect switch)

CUT ALONG DOTTED LINE








 PremierLink Control
 CO2 Sensor (IAQ Control)
 Power Exhaust
 Horizontal Power Exhaust Module (Single Fan)
 –20 F Motormaster® Low Ambient Control Kit
 Programmable Setback Thermostat
 Electrical Mechanical Thermostat and Subbase
 Indoor Fan/Filter Status Indicator
 Electric Resistance Heat Coils
 62AQ Energy$Recycler™ Mounting Kit
 62AQ Energy$Recycler Supply Air Blower
 62AQ Energy$Recycler 460-V Transformer
 62AQ Energy$Recycler 575-V Transformer
 Humidistat
 Light Commercial Thermidistat™ Device
 UV-C Lamps
 Other ____________________

3

4

CERTIFIED DIMENSION PRINT

5

CUT ALONG DOTTED LINE

CERTIFIED DIMENSION PRINT

CUT ALONG DOTTED LINE

6

CERTIFIED ROOF CURB DIMENSION PRINT

7

CUT ALONG DOTTED LINE

CERTIFIED ROOF CURB DIMENSION PRINT

CUT ALONG DOTTED LINE



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2005:12:01 10:25:21Z
Modify Date                     : 2005:12:01 10:51:33-05:00
Page Count                      : 8
Creation Date                   : 2005:12:01 10:25:21Z
Producer                        : Acrobat Distiller 4.0 for Windows
Mod Date                        : 2005:12:01 10:51:33-05:00
Author                          : Carrier Corporation
Metadata Date                   : 2005:12:01 10:51:33-05:00
Title                           : 
Creator                         : Carrier Corporation
EXIF Metadata provided by EXIF.tools

Navigation menu