Carrier Home Standby Aspba1Cca016 Users Manual CarrierAC16kW9.27.06
HOME STANDBY ASPBA1CCA016 ASPBS16-1SS
ASPBA1CCA016 to the manual 03855598-f8b0-4e0c-850b-978fe5d67e55
2015-01-24
: Carrier Carrier-Home-Standby-Aspba1Cca016-Users-Manual-310977 carrier-home-standby-aspba1cca016-users-manual-310977 carrier pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | ![]() |
Open PDF In Browser | View PDF |
Home Standby - 16kW Air-Cooled Gas Engine Generator Sets Ultra Quiet Mode Low Speed Exercise 59 dB(A) at 23 feet Continuous Standby Power Rating — 16kW 60Hz Models: ASPBS1CCA016 (Steel) ASPBA1CCA016 (Aluminum) INCLUDES: • Automatic Transfer Switch With Built-In 16-Circuit Emergency Load Center • Electronic Governor • Pre-wired External Connection Box • Flexible Fuel Line • Composite Mounting Pad • Pre-wired conduits • Natural Gas or LP Gas Operation • UL 2200 Listed to U.S. and Canadian Standards FEATURES INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of CARRIER’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose CARRIER with the confidence that these systems will provide superior performance. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. SINGLE SOURCE SERVICE RESPONSE from Carrier’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. You are never on your own when you own a CARRIER SYSTEM. CARRIER TRANSFER SWITCHES. Long life and reliability are synonymous with CARRIER. One reason for this confidence is that the CARRIER product line includes its own transfer systems and controls for total system compatibility. TEST CRITERIA: > PROTOTYPE TESTED > SYSTEM TORSIONAL TESTED > NEMA MG1-22 EVALUATION > MOTOR STARTING ABILITY INSTALLATION SYSTEM UNIT MICROPROCESSOR CONTROL TRANSFER SWITCH GENERATOR ENGINE HOME STANDBY SPECIFICATIONS Home Standby - 16kW •Durable OHVI Design Maximizes engine “breathing” for increased fuel efficiency. Cylinder walls run cooler, reducing oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly longer life than competitive engines. •”Spiny-lok” cast iron cylinder walls Rigid construction and added durability provide long engine life. •Electronic ignition, spark advance and compression release These features combine to assure smooth, quick starting every time. •Full pressure lubrication system Superior lubrication to all vital bearings means better performance, less maintenance and significantly longer engine life. •Low oil pressure shutdown system Superior shutdown protection prevents catastrophic engine damage due to low oil. •High temperature shutdown Prevents damage due to overheating. •Revolving field Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. •Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. •Displaced phase excitation Maximizes motor starting capability. Provides more surge capability than brushless generator designs. •Automatic voltage regulation Regulates the output voltage to ±2% prevents damaging voltage spikes. •UL 2200 Listed For your safety •Fully Automatic Transfers your vital electrical loads to the energized source of power. •Remote Mounting Mounts near your existing distribution panel for simple, low cost installation. •UL Listed For your safety •Manual/Auto/Off switch Selects the operating mode. •Utility voltage sensing Constantly monitors utility voltage, setpoints 60% dropout, 70% pick-up, of standard voltage. •Utility interrupt delay Prevents nuisance start-ups of the engine, set point approximately 10 seconds. •Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 10 seconds. •Engine cool-down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. •Seven day exerciser Operates engine to prevent oil seal drying and damage between power outages. •Timed Trickle Battery charger Maintains battery amperage to insure starting. •Main Line Circuit Breaker Protects generator from overload. •Weather protective enclosure Ensures protection against mother nature. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Aluminum enclosure available - (Model 05244) •Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. •Small, compact, attractive Makes for an easy, eye appealing installation. •Pre-wired External Connection Box Easy Installation - Virtually all hardware included, plus step-by-step photographed Installation Guide. •1’ Flexible Fuel Line •Composite Mounting Pad •Pre-wired conduits •UL Listed wire nuts Home Standby - 16kW GENERATOR Model ASPBS1CCA016 - Steel, Model ASPBA1CCA016 - Aluminum Rated Maximum Continuous Power Capacity (LP)................................................................................................ 16,000 Watts* Rated Maximum Continuous Power Capacity (NG)............................................................................................... 15,000 Watts* Rated Voltage.............................................................................................................................................................. 120/240 Rated Maximum Continuous Load Current 120 Volts ........................................................................................................................................................ 133.3 LP/125 NG 240 Volts ....................................................................................................................................................... 66.6 LP/62.5 NG Main Line Circuit Breaker .......................................................................................................................................... 65 Amp Phase ............................................................................................................................................................................... 1 Number of Rotor Poles .................................................................................................................................................... 2 Rated AC Frequency .................................................................................................................................................... 60Hz Power Factor .................................................................................................................................................................... 1 Battery Requirement (not included) .................................................................... Group 26, 12 Volt Netgative Ground and 525 Cold-cranking Amperes Minimum Unit Weight ................................................................................................................................................ 445 lbs. (Steel), 414 lbs. (Alum) Dimensions (L” x W” x H”).................................................................................................................................... 48 x 24 x 28-1/4 Sound output in dB(A) at 23 ft. with generator operating at full load.............................................................................. 71.5 Sound output in dB(A) at 23 ft. with generator in Ultra Quiet exercise mode ................................................................ 59 ENGINE Model ASPBS1CCA016 - Steel, Model ASPBA1CCA016 - Aluminum Type of Engine........................................................................................................................................................ OHVI V-TWIN Number of Cylinders......................................................................................................................................................... 2 Rated Horsepower................................................................................................................................................ 30 @ 3,600 rpm Displacement................................................................................................................................................................ 992cc Cylinder Block............................................................................................................................................ Aluminum w/Cast Iron Sleeve Valve Arrangement................................................................................................................................................ Overhead Valve Ignition System................................................................................................................................................. Solid-state w/Magneto Governor System........................................................................................................................................................ Electronic Compression Ratio......................................................................................................................................................... 9.5:1 Starter........................................................................................................................................................................... 12Vdc Oil Capacity Including Filter................................................................................................................................. Approx. 1.7 Qts. Standby Operating RPM.............................................................................................................................................. 3,600 Exercise RPM ............................................................................................................................................................. 2400 Fuel Consumption Natural Gas cu.ft./hr. ........................................1/2 Load 173 ........................................Full Load 245 Liquid Propane ft3/hr (gal/hr) ........................................1/2 Load 59 (1.59) ........................................Full Load 92 (2.51) Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas CONTROLS Mode Switch -Auto ............................................................................................................................................... Automatic Start on Utility failure 7 day exerciser -Off ............................................................................................................................................ Stops unit. Power is removed Control and charger still operate -Manual/Test (start) ...................................................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place. Engine Start Sequence Cyclic cranking: 7 sec. on, 7 rest (90 sec. maximum duration) Engine Warm-up ..................................................................................................................................................... 10 seconds Engine Cool-Down ..................................................................................................................................................... 1 minute Starter Lock-out ........................................................................................................................................ Starter cannot re-engage until 5 sec. after engine has stopped. 2.5 Amp Timed Trickle Battery Charger .................................................................................................................. Standard Automatic Voltage Regulator w/Overvoltage Protection ............................................................................................ Standard Automatic Low Oil Pressure Shutdown ..................................................................................................................... Standard Overspeed Shutdown ............................................................................................................................................ Standard, 72Hz High Temperature Shutdown ..................................................................................................................................... Standard Overcrank Protection ................................................................................................................................................. Standard Safety Fuse ............................................................................................................................................................... Standard Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F). Home Standby - 16kW TRANSFER SWITCH & EMERGENCY LOAD CENTER Models: ASPBS1CC016 & ASPBA1CC016 No. of Poles ......................................................................................................................................... 2 Current Rating (amps) ....................................................................................................................... 100 Voltage Rating (VAC) ........................................................................................................................ 250 Utility Voltage Monitor (fixed) -Pick-up ................................................................................................... 70% -Dropout ................................................................................................... 60% Return to Utility .................................................................................................... approx. 13 sec. Exerciser weekly for 12 minutes .................................................................................................... Standard UL Listed ....................................................................................................................................... Standard Dimensions (H” x W” x D”) ....................................................................................................... 26.5 x 12.5 x 7 Total of Pre-wired Circuits .................................................................................................................. 16 No. 15A 120V ................................................................................................................ 5 No. 20A 120V ................................................................................................................ 5 No. 20A 240V ................................................................................................................ 1 No. 40A 240V ................................................................................................................ 1 No. 50A 240V ................................................................................................................ 1 Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts .................................................................................................... 10,000 Mechanical Dimensions (in inches) Current No. of Height Rating Poles H1 H2 100 UL Listed 2 26.5 29.25 W2 W1 H1 Terminal Wire Ranges ATS Rated Amps Switch Terminal 100A 2-Pole UL 1 x 1/0-12 H2 Width W1 W2 8.14 12.5 Neutral Lug/Stud 1 x 3/8-16 Stud Transfer Switch Features • Electrically operated, mechanically-held contacts for fast, positive connections. • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • 160 millisecond transfer time. • Dual coil design. • Main contacts are silver plated or silver alloy to resist welding and sticking. Depth • Nema 1 enclosure is standard on the 100 amp switch. 7 Ground Lug 1 x 2/0-14 Conduit sizes vary depending on model # CARRIER, INC. CarrierAC16kW 9.06 • 7310 WEST MORRIS STREET • INDIANAPOLIS, IN 46231 W E B S I T E : w w w. c a r r i e r. c o m CATALOG NO. ASPBS16-1SS © 2006 Carrier Corporation. All rights reserved. All specifications are subject to change without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 4 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:db746219-245f-4fb1-947f-aab0531ef365 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2006:09:29 14:57:01-05:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2006:10:02 13:59:17-04:00 Metadata Date : 2006:10:02 13:59:17-04:00 Document ID : uuid:e1e07eff-2e81-4464-ae6d-f76d83001a24 Instance ID : uuid:e840cbe3-a44e-4bbb-af05-b9362b92a309 Format : application/pdf Title : CarrierAC16kW9.27.06.qxd Creator : dpepper Author : dpepperEXIF Metadata provided by EXIF.tools