Carrier Weathermaker 48 50Aj Users Manual 48_50a 9t
4850AJ to the manual 7ad0b691-d363-4490-b3d9-0a7624fa0139
2015-01-24
: Carrier Carrier-Weathermaker-48-50Aj-Users-Manual-310498 carrier-weathermaker-48-50aj-users-manual-310498 carrier pdf
Open the PDF directly: View PDF .
Page Count: 190
Download | |
Open PDF In Browser | View PDF |
WEATHERMAKER® 48/50AJ,AK,AW,AY,A2,A3,A4,A5020-060 Single Package Large Rooftop Units with COMFORTLINK™ Version 5.x Controls Controls, Start-Up, Operation, Service and Troubleshooting CONTENTS Page SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . .2 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Conventions Used in this Manual. . . . . . . . . . . . . . . . . . . .3 BASIC CONTROL USAGE. . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 ComfortLink Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Scrolling Marquee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Accessory Navigator™ Display. . . . . . . . . . . . . . . . . . . . . .4 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 System Pilot™ Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 CCN Tables and Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 • GENERICS STATUS DISPLAY TABLE START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27 Unit Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Unit Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Internal Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Accessory Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Crankcase Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Evaporator Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Gas Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 CONTROLS QUICK START . . . . . . . . . . . . . . . . . . . . . . 27-29 Two-Stage Constant Volume Units with Mechanical Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . .27 Two-Stage Constant Volume Units with Space Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Variable Air Volume Units Using Return Air Sensor or Space Temperature Sensor . . . . . . . . . . . . . . . . . . . .28 Multi-Stage Constant Volume Units with Mechanical Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . .28 Multi-Stage Constant Volume Units with Space Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Economizer Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Indoor Air Quality Options. . . . . . . . . . . . . . . . . . . . . . . . . .29 Exhaust Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Programming Operating Schedules . . . . . . . . . . . . . . . .29 SERVICE TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29,30 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Service Test Mode Logic . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Independent Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Fans in Service Test Mode . . . . . . . . . . . . . . . . . . . . . . . . .30 Cooling in Service Test Mode. . . . . . . . . . . . . . . . . . . . . . .30 Heating in Service Test Mode. . . . . . . . . . . . . . . . . . . . . . .30 THIRD PARTY CONTROL . . . . . . . . . . . . . . . . . . . . . . . . 31,32 Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Alarm Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Remote Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 VFD Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Supply Air Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Demand Limit Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Demand Controlled Ventilation Control . . . . . . . . . . . . .31 CONTROLS OPERATION . . . . . . . . . . . . . . . . . . . . . . . . 32-75 Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 • SYSTEM MODES • HVAC MODES Page Unit Configuration Submenu . . . . . . . . . . . . . . . . . . . . . . . 35 Cooling Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 • SETTING UP THE SYSTEM • MACHINE DEPENDENT CONFIGURATIONS • SET POINTS • SUPPLY AIR RESET CONFIGURATION • COOLING CONFIGURATION • COMPRESSOR SAFETIES • COMPRESSOR TIME GUARDS • COOL MODE SELECTION PROCESS • COOLING MODE DIAGNOSTIC HELP • SUMZ COOLING ALGORITHM • DEMAND LIMIT CONTROL • HEAD PRESSURE CONTROL • ECONOMIZER INTEGRATION WITH MECHANICAL COOLING Heating Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 • SETTING UP THE SYSTEM • HEAT MODE SELECTION PROCESS • TEMPERATURE DRIVEN HEAT MODE EVALUATION • HEAT MODE DIAGNOSTIC HELP • INTEGRATED GAS CONTROL BOARD LOGIC • RELOCATE SAT SENSOR FOR HEATING IN LINKAGE SYSTEMS • MORNING WARM UP • TEMPERING MODE Static Pressure Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 • OPERATION • SETTING UP THE SYSTEM • STATIC PRESSURE RESET OPERATION • RELATED POINTS Fan Status Monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 • GENERAL • SETTING UP THE SYSTEM • SUPPLY FAN STATUS MONITORING LOGIC Dirty Filter Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Economizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 • SETTING UP THE SYSTEM • ECONOMIZER OPERATION • UNOCCUPIED ECONOMIZER FREE COOLING • ECONOMIZER OPERATION CONFIGURATION • ECONOMIZER DIAGNOSTIC HELP Building Pressure Control. . . . . . . . . . . . . . . . . . . . . . . . . . 63 • BUILDING PRESSURE CONFIGURATION • CONSTANT VOLUME 2-STAGE CONTROL OPERATION • MULTIPLE POWER EXHAUST STAGE BUILDING PRESSURE CONTROL OPERATION • VFD POWER EXHAUST BUILDING PRESSURE CONTROL Smoke Control Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 • FIRE-SMOKE INPUTS • AIRFLOW CONTROL DURING THE FIRE-SMOKE MODES • RELEVANT ITEMS Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480077-01 Printed in U.S.A. Form 48/50A-9T Pg 1 6-10 Replaces: 48/50A-7T CONTENTS (cont) SAFETY CONSIDERATIONS Page Indoor Air Quality Control. . . . . . . . . . . . . . . . . . . . . . . . . . 67 • OPERATION • SETTING UP THE SYSTEM • PRE-OCCUPANCY PURGE Dehumidification and Reheat . . . . . . . . . . . . . . . . . . . . . . 69 • SETTING UP THE SYSTEM • OPERATION Temperature Compensated Start. . . . . . . . . . . . . . . . . . . 71 • SETTING UP THE SYSTEM • TEMPERATURE COMPENSATED START LOGIC Carrier Comfort Network® (CCN) System. . . . . . . . . . . 71 Alert Limit Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Sensor Trim Configuration . . . . . . . . . . . . . . . . . . . . . . . . . 73 Discrete Switch Logic Configuration . . . . . . . . . . . . . . . 74 Display Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Remote Control Switch Input. . . . . . . . . . . . . . . . . . . . . . . 74 Hot Gas Bypass. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Space Temperature Offset . . . . . . . . . . . . . . . . . . . . . . . . . 75 TIME CLOCK CONFIGURATION . . . . . . . . . . . . . . . . . 75-77 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . 77-101 Complete Unit Stoppage . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Single Circuit Stoppage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Service Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Restart Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Thermistor Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 77 Transducer Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 78 Forcing Inputs and Outputs . . . . . . . . . . . . . . . . . . . . . . . . 90 Run Status Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 • AUTO VIEW OF RUN STATUS • ECONOMIZER RUN STATUS • COOLING INFORMATION • MODE TRIP HELPER • CCN/LINKAGE DISPLAY TABLE • COMPRESSOR RUN HOURS DISPLAY TABLE • COMPRESSOR STARTS DISPLAY TABLE • TIME GUARD DISPLAY TABLE • SOFTWARE VERSION NUMBERS DISPLAY TABLE Alarms and Alerts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 MAJOR SYSTEM COMPONENTS. . . . . . . . . . . . . . 101-127 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Factory-Installed Components . . . . . . . . . . . . . . . . . . . . 101 Accessory Control Components . . . . . . . . . . . . . . . . . . 124 SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128-139 Service Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 Evaporator Fan Performance Adjustment . . . . . . . . . 130 Evaporator Fan Coupling Assembly. . . . . . . . . . . . . . . 130 Evaporator Fan Service and Replacement . . . . . . . . 131 Belt Tension Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Evaporator-Fan Motor Replacement. . . . . . . . . . . . . . . 131 Condenser-Fan Adjustment . . . . . . . . . . . . . . . . . . . . . . . 132 Four-Inch Filter Replacement . . . . . . . . . . . . . . . . . . . . . 132 Power Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Refrigerant Charge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Thermostatic Expansion Valve (TXV). . . . . . . . . . . . . . 132 Gas Valve Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Main Burners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Filter Drier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 APPENDIX A — LOCAL DISPLAY TABLES . . . . 140-147 APPENDIX B — CCN TABLES . . . . . . . . . . . . . . . . . 148-160 APPENDIX C — VFD INFORMATION. . . . . . . . . . . 161-169 APPENDIX D — MODE SELECTION PROCESS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 APPENDIX E — UPC OPEN CONTROLLER. . . . 171-182 INDEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 CONTROLS SET POINT AND CONFIGURATION LOG. . . . . . . . . . . . . . . . . . CL-1 to CL-5 UNIT START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . . CL-6 Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair, or service air-conditioning equipment. Untrained personnel can perform the basic maintenance functions of replacing filters. Trained service personnel should perform all other operations. When working on air-conditioning equipment, observe precautions in the literature, tags and labels attached to the unit, and other safety precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for unbrazing operations. Have fire extinguishers available for all brazing operations. WARNING Before performing service or maintenance operation on unit turn off and lock off main power switch to unit. Electrical shock can cause personal injury and death. Shut off all power to this equipment during installation and service. The unit may have an internal non-fused disconnect or a field-installed disconnect. Note that the unit may also be equipped with a convenience outlet, that this outlet is wired to the line side of the unitmounted disconnect and will remain hot when the disconnect in the unit is off. There is a separate fuse/ disconnect for the convenience outlet. CAUTION Puron® refrigerant (R-410A) systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on Puron refrigerant equipment. If service equipment is not rated for Puron refrigerant, equipment damage or personal injury may result. CAUTION This unit uses a microprocessor-based electronic control system. Do not use jumpers or other tools to short out components or to bypass or otherwise depart from recommended procedures. Any short-to-ground of the control board or accompanying wiring may destroy the electronic modules or electrical components. WARNING 1. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Refer to the User’s Information Manual provided with this unit for more details. 2. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. What to do if you smell gas: 1. DO NOT try to light any appliance. 2. DO NOT touch any electrical switch, or use any phone in your building. 3. IMMEDIATELY call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 4. If you cannot reach your gas supplier call the fire department. 2 A scheduling function, programmed by the user, controls the unit occupied/unoccupied schedule. Up to 8 different schedules can be programmed. The controls also allow the service person to operate a quick test so that all the controlled components can be checked for proper operation. GENERAL This book contains Start-Up, Controls Operation, Troubleshooting and Service information for the 48/50A Series rooftop units. See Table 1. These units are equipped with ComfortLink™ controls. Use this guide in conjunction with the separate installation instructions packaged with the unit. Refer to the Wiring Diagrams literature for more detailed wiring information. Conventions Used in This Manual — The following conventions for discussing configuration points for the local display (scrolling marquee or Navigator accessory) will be used in this manual. Point names will be written with the Mode name first, then any sub-modes, then the point name, each separated by an arrow symbol (). Names will also be shown in bold and italics. As an example, the IAQ Economizer Override Position which is located in the Configuration mode, Indoor Air Quality Configuration sub-mode, and the Air Quality Set Points sub-sub-mode, would be written as Configuration IAQIAQ.SPIQ.O.P. A list of point names can be found in Appendix A. This path name will show the user how to navigate through the local display to reach the desired configuration. The user would scroll through the modes and submodes using the and keys. The arrow symbol in the path name represents pressing ENTER to move into the next level of the menu structure. Table 1 — A Series Product Line UNIT 48AJ 48AK 48AW 48AY 48A2 48A3 48A4 48A5 50AJ 50AK 50AW 50AY 50A2 50A3 50A4 50A5 APPLICATION CV Unit with Gas Heat, Vertical Supply VAV Units with Gas Heat, Vertical Supply CV Unit with Gas Heat, Horizontal Supply VAV Unit with Gas Heat, Horizontal Supply CV Unit with Gas Heat, Vertical Supply with MCHX Coil VAV Unit with Gas Heat, Vertical Supply with MCHX Coil CV Unit with Gas Heat, Horizontal Supply with MCHX Coil VAV Unit with Gas Heat, Horizontal Supply with MCHX Coil CV Unit with Optional Electric Heat, Vertical Supply VAV Unit with Optional Electric Heat, Vertical Supply CV Unit with Optional Electric Heat, Horizontal Supply VAV Unit with Optional Electric Heat, Horizontal Supply CV Unit with Optional Electric Heat, Vertical Supply with MCHX Coil VAV Unit with Optional Electric Heat, Vertical Supply with MCHX Coil CV Unit with Optional Electric Heat, Horizontal Supply with MCHX Coil VAV Unit with Optional Electric Heat, Horizontal Supply with MCHX Coil When a value is included as part of the path name, it will be shown at the end of the path name after an equals sign. If the value represents a configuration setting, an explanation will be shown in parentheses after the value. As an example, ConfigurationIAQAQ.CFIQ.AC = 1 (IAQ Analog Input). LEGEND CV — Constant Volume MCHX — Microchannel Heat Exchanger VAV — Variable Air Volume Pressing the ESCAPE and ENTER keys simultaneously at any time will display an expanded text description of the fourcharacter point name. The expanded description is shown in the local display tables (Appendix A). The A Series units provide ventilation, cooling, and heating (when equipped) in variable air volume (VAV), variable volume and temperature (VVT®), and constant volume (CV) applications. The A Series units contain the factory-installed ComfortLink™ control system which provides full system management. The main base board (MBB) stores hundreds of unit configuration settings and 8 time of day schedules. The MBB also performs self diagnostic tests at unit start-up, monitors the operation of the unit, and provides alarms and alert information. The system also contains other optional boards that are connected to the MBB through the Local Equipment Network (LEN). Information on system operation and status are sent to the MBB processor by various sensors and optional boards that are located at the unit. Access to the unit controls for configuration, set point selection, schedule creation, and service can be done through a unit-mounted scrolling marquee. Access can also be done through the Carrier Comfort Network® (CCN) system using the ComfortVIEW™ software, the accessory Navigator™ handheld display, or the System Pilot™ interface. The ComfortLink system controls all aspects of the rooftop. It controls the supply-fan motor, compressors, and economizers to maintain the proper temperature conditions. The controls also cycle condenser fans to maintain suitable head pressure. All VAV units are equipped with a standard VFD (variable frequency drive) for supply fan speed control and supply duct pressure control. The ComfortLink controls adjust the speed of the VFD based on a static pressure sensor input. In addition, the ComfortLink controls can raise or lower the building pressure using multiple power exhaust fans controlled from economizer damper position or from a building pressure sensor. The control safeties are continuously monitored to ensure safe operation under all conditions. Sensors include suction pressure transducers, discharge pressure transducers, and saturated condensing temperature sensors which allow for display of operational pressures and saturation temperatures. The CCN point names are also referenced in the local display tables for users configuring the unit with CCN software instead of the local display. The CCN tables are located in Appendix B of this manual. BASIC CONTROL USAGE ComfortLink Controls — The ComfortLink control system is a comprehensive unit-management system. The control system is easy to access, configure, diagnose and troubleshoot. The control is flexible, providing two types of constant volume cooling control sequences, two variable air volume cooling control sequences, and heating control sequences for two-stage electric and gas systems, and for multiple-stage gas heating, in both Occupied and Unoccupied schedule modes. This control also manages: • VAV duct pressure (through optional VFD), with reset • Building pressure through two different power exhaust schemes • Condenser fan cycling for mild ambient head pressure control • Space ventilation control, in Occupied and Unoccupied periods, using CO2 sensors or external signals, with ventilation defined by damper position • Smoke control functions • Occupancy schedules • Occupancy or start/stop sequences based on third party signals • Alarm status and history and run time data • Management of a complete unit service test sequence 3 marquee, the user can access a built-in test routine that can be used at start-up commissioning to diagnose operational problems with the unit. System diagnostics are enhanced by the use of multiple external sensors for air temperatures, air pressures, refrigerant temperatures, and refrigerant pressures. Unit-mounted actuators provide digital feedback data to the unit control. The ComfortLink control system is fully communicating and cable-ready for connection to the Carrier Comfort Network® (CCN) building management system. The control provides high-speed communications for remote monitoring via the Internet. Multiple units can be linked together (and to other ComfortLink control equipped units) using a 3-wire communication bus. The ComfortLink control system is easy to access through the use of a unit-mounted display module. There is no need to bring a separate computer to this unit for start-up. Access to control menus is simplified by the ability to quickly select from 11 menus. A scrolling readout provides detailed explanations of control information. Only four, large, easy-to-use buttons are required to maneuver through the entire controls menu. For added service flexibility, an accessory hand-held Navigator module is also available. This portable device has an extended communication cable that can be plugged into the unit’s communication network either at the main control box or at the opposite end of the unit, at a remote modular plug. The Navigator display provides the same menu structure, control access and display data as is available at the unit-mounted scrolling marquee display. Accessory Navigator™ Display — The accessory hand-held Navigator display can be used with the A Series units. See Fig. 2. The Navigator display operates the same way as the scrolling marquee device. The Navigator display is plugged into the RJ-14 (LEN) jack in the main control box on the COMM board. The Navigator display can also be plugged into the RJ-14 jack located on the ECB (economizer control board) located in the auxiliary control box. Operation — All units are shipped from the factory with the scrolling marquee display, which is located in the main control box. See Fig. 1. In addition, the ComfortLink™ controls also support the use of the handheld Navigator display. Both displays provide the user with an interface to the ComfortLink control system. The displays have and arrow keys, an ESCAPE key and an ENTER key. These keys are used to navigate through the different modes of the display structure. The Navigator and the scrolling marquee displays operate in the same manner, except that the Navigator display has multiple lines of display and the scrolling marquee has a single line. All further discussions and examples in this document will be based on the scrolling marquee display. See Table 2 for the menu structure. The four keys are used to navigate through the display structure, which is organized in a tiered mode structure. If the buttons have not been used for a period, the display will default to the AUTO VIEW display category as shown under the RUN STATUS category. To show the top-level display, press the ESCAPE key until a blank display is shown. Then use the and arrow keys to scroll through the top-level categories (modes). These are listed in Appendix A and will be indicated on the scrolling marquee by the LED next to each mode listed on the face of the display. Scrolling Marquee — This device is the standard inter- face used to access the control information, read sensor values, and test the unit. The scrolling marquee is located in the main control box. The scrolling marquee display is a 4-key, 4-character LED (light-emitting diode) display module. The display also contains an Alarm Status LED. See Fig. 1. The display is easy to operate using 4 buttons and a group of 11 LEDs that indicate the following menu structures, referred to as modes (see Appendix A): • Run Status • Service Test • Temperatures • Pressures • Set points • Inputs • Outputs • Configuration • Timeclock • Operating Modes • Alarms Through the scrolling marquee, the user can access all of the inputs and outputs to check on their values and status, configure operating parameters plus evaluate the current decision status for operating modes. Because the A Series units are equipped with suction pressure and saturated condensing temperature transducers, the scrolling marquee can also display refrigerant circuit pressures typically obtained from service gages. The control also includes an alarm history which can be accessed from the display. In addition, through the scrolling When a specific mode or sub-mode is located, push the ENTER key to enter the mode. Depending on the mode, there may be additional tiers. Continue to use the and keys and the ENTER keys until the desired display item is found. At any time, the user can move back a mode level by pressing the ESCAPE key. Once an item has been selected the display will flash showing the item, followed by the item value and then followed by the item units (if any). Co m NA TI M E EWT LW T S E TP MO Run Status Li n k ATO R 12. 54. 58 44. 6 F 4 4 . 01 F F DE Ala rm Run Status Servi ce Te st Temp eratur es Pres sures Setpo ints Inputs MODE fort VIG St atu s Outpu ts Confi gurat ion Time Clock Opera ting Mode Alarm s s Service Test Temperature ESC Pressures Setpoints Inputs ENT Alarm Status ER Outputs Configuration Time Clock Operating Modes Alarms ESCAPE ENTER A30-2239 30-650 Fig. 1 — Scrolling Marquee Fig. 2 — Accessory Navigator Display 4 Items in the Configuration and Service Test modes are password protected. The display will flash PASS and WORD when required. Use the ENTER and arrow keys to enter the four digits of the password. The default password is 1111. Pressing the ESCAPE and ENTER keys simultaneously will scroll an expanded text description across the display indicating the full meaning of each display point. Pressing the ESCAPE and ENTER keys when the display is blank (MODE LED level) will return the display to its default menu of rotating AUTO VIEW display items. In addition, the password will need to be entered again before changes can be made. MODIFY/ SELECT NAVIGATE/ EXIT Changing item values or testing outputs is accomplished in the same manner. Locate and display the desired item. If the display is in rotating auto-view, press the ENTER key to stop the display at the desired item. Press the ENTER key again so that the item value flashes. Use the arrow keys to change the value of state of an item and press the ENTER key to accept it. Press the ESCAPE key and the item, value or units display will resume. Repeat the process as required for other items. SCROLL + PAGE - If the user needs to force a variable, follow the same process as when editing a configuration parameter. A forced variable will be displayed with a blinking “f” following its value. For example, if supply fan requested (FAN.F) is forced, the display shows “YESf”, where the “f” is blinking to signify a force on the point. Remove the force by selecting the point that is forced with the ENTER key and then pressing the and arrow keys simultaneously. A33-1050 Fig. 3 — System Pilot™ User Interface GENERICS STATUS DISPLAY TABLE — The GENERICS points table allows the service/installer the ability to create a custom table in which up to 20 points from the 5 CCN categories (Points, Config, Service-Config, Set Point, and Maintenance) may be collected and displayed. In the Service-Config table section, there is a table named “generics”. This table contains placeholders for up to 20 CCN point names and allows the user to decide which points are displayed in the GENERICS points table under the local display. Each one of these placeholders allows the input of an 8-character ASCII string. Using a CCN interface, enter the Edit mode for the Service-Config table “generics” and enter the CCN name for each point to be displayed in the custom points table in the order they will be displayed. When done entering point names, download the table to the rooftop unit control. Depending on the unit model, factory-installed options and field-installed accessories, some of the items in the various Mode categories may not apply. System Pilot™ Interface — The System Pilot (33PILOT-01) device is a component of Carrier’s 3V™ system and serves as a user-interface and configuration tool for all Carrier communicating devices. The System Pilot device can be used to install and commission a 3V zoning system, linkage compatible air source, universal controller, and all other devices operating on the CCN system. Additionally, the System Pilot device can serve as a wall-mounted temperature sensor for space temperature measurement. The occupant can use the System Pilot device to change set points. A security feature is provided to limit access of features for unauthorized users. See Fig. 3 for System Pilot details. IMPORTANT: The computer system software (ComfortVIEW™, Service Tool, etc.) that is used to interact with CCN controls always saves a template of items it considers as static (e.g., limits, units, forcibility, 24-character text strings, and point names) after the software uploads the tables from a control. Thereafter, the software is only concerned with run time data like value and hardware/force status. With this in mind, it is important that anytime a change is made to the Service-Config table “generics” (which in turn changes the points contained in the GENERICS point table), that a complete new upload be performed. This requires that any previous table database be completely removed first. Failure to do this will not allow the user to display the new points that have been created and the CCN interface will have a different table database than the unit control. CCN Tables and Display — In addition to the unit- mounted scrolling marquee display, the user can also access the same information through the CCN tables by using the Service Tool or other CCN programs. Details on the CCN tables are summarized in Appendix B. The variable names used for the CCN tables and the scrolling marquee tables may be different and more items are displayed in the CCN tables. As a reference, the CCN variable names are included in the scrolling marquee tables and the scrolling marquee names are included in the local display tables in Appendix B. 5 Table 2 — Scrolling Marquee Menu Display Structure (ComfortLink™ Display Modes) RUN STATUS Auto View of Run Status (VIEW) SERVICE TEST Service Test Mode (TEST) TEMPERATURES PRESSURES SETPOINTS INPUTS OUTPUTS CONFIGURATION TIME CLOCK Air Temperatures (AIR.T) Air Pressures (AIR.P) Occupied Heat Setpoint (OHSP) General Inputs (GEN.I) Fans (FANS) Unit Configuration (UNIT) Time of Day (TIME) Econ Run Status (ECON) Software Command Disable (STOP) Refrigerant Temperatures (REF.T) Compressor Feedback (FD.BK) Cooling (COOL) Cooling Information (COOL) Soft Stop Request (S.STP) Mode Trip Helper (TRIP) Supply Fan Request (FAN.F) Refrigerant Pressures (REF.P) Occupied Cool Setpoint (OCSP) Unoccupied Heat Setpoint (UHSP) Unoccupied Cool Setpoint (UCSP) Compressor Run Hours (HRS) Test Independent Outputs (INDP) VAV Occ Cool On (V.C.ON) Compressor Starts (STRT) Timeguards (TMGD) Software Version Numbers (VERS) Test Fans (FANS) Test Cooling (COOL) Test Heating (HEAT) Fire-Smoke Modes (FIRE) Heat - Cool Setpoint (GAP) Thermostat Inputs (STAT) 4 in. Filter Change Mode (F.4.CH) CCN Linkage (LINK) Relative Humidity (REL.H) Air Quality Sensors (AIR.Q) VAV Occ Cool Off (V.C.OF) Supply Air Setpoint (SASP) Reset Inputs (RSET) 4-20 Milliamp Inputs (4-20) Heating (HEAT) Economizer (ECON) General Outputs (GEN.O) Cooling Configuration (COOL) Evap/Discharge Temp. Reset (EDT.R) Heating Configuration (HEAT) Supply Static Press. Config. (SP) Economizer Configuration (ECON) Building Press. Configs (BP) Cool/Heat Setpt. Offsets (D.LV.T) Supply Air Setpoint Hi (SA.HI) Demand Limit Config. (DMD.L) Supply Air Setpoint Lo (SA.LO) Indoor Air Quality Cfg. (IAQ) Heating Supply Air Setpoint (SA.HT) Dehumidification Config. (DEHU) Tempering Purge SASP (T.PRG) CCN Configuration (CCN) Tempering in Cool SASP (T.CL) Alert Limit Config. (ALLM) Tempering in Vent Occ SASP (T.V.OC) Sensor Trim Config. (TRIM) Tempering in Vent Unocc. SASP (T.V.UN) Switch Logic (SW.LG) Display Configuration (DISP) 6 OPERATING MODES System Mode (SYS.M) Month, Date, Day and Year (DATE) HVAC Mode (HVAC) Local Time Schedule (SCH.L) Control Type (CTRL) Local Holiday Schedules (HOL.L) Daylight Savings Time (DAY.S) Mode Controlling Unit (MODE) ALARMS Currently Active Alarms (CURR) Reset All Current Alarms (R.CUR) Alarm History (HIST) Controls — Use the following steps for the controls: START-UP IMPORTANT: The unit is shipped with the unit control disabled. To enable the control, set Local Machine Disable (Service TestSTOP) to No. IMPORTANT: Do not attempt to start unit, even momentarily, until all items on the Start-Up Checklist and the following steps have been completed. 1. Set any control configurations that are required (fieldinstalled accessories, etc.). The unit is factory configured for all appropriate factory-installed options. 2. Enter unit set points. The unit is shipped with the set point default values. If a different set point is required use the scrolling marquee, Navigator™ accessory or Service Tool software to change the configuration valves. 3. If the internal unit schedules are going to be used configure the Occupancy schedule. 4. Verify that the control time periods programmed meet current requirements. 5. Using Service Test mode, verify operation of all major components. 6. If the unit is a VAV unit make sure to configure the VFD static pressure set point using the display. To checkout the VFD use the VFD instructions shipped with the unit. Unit Preparation — Check that unit has been installed in accordance with the installation instructions and applicable codes. Unit Setup — Make sure that the economizer hoods have been installed and that the outdoor filters are properly installed. Internal Wiring — Ensure that all electrical connections in the control box are tightened as required. If the unit has staged gas heat make sure that the leaving air temperature (LAT) sensors have been routed to the supply ducts as required. Accessory Installation — Check to make sure that all accessories including space thermostats and sensors have been installed and wired as required by the instructions and unit wiring diagrams. Crankcase Heaters — Crankcase heaters are energized as long as there is power to the unit, except when the compressors are running. Gas Heat — Verify gas pressure before turning on gas heat as follows: 1. Turn off field-supplied manual gas stop, located external to the unit. 2. Connect pressure gages to supply gas tap, located at fieldsupplied manual shutoff valves. 3. Connect pressure gages to manifold pressure tap on unit gas valve. 4. Supply gas pressure must not exceed 13.5 in. wg. Check pressure at field-supplied shut-off valve. 5. Turn on manual gas stop and initiate a heating demand. Jumper R to W1 in the control box to initiate heat. 6. Use the Service Test procedure to verify heat operation. 7. After the unit has run for several minutes, verify that incoming pressure is 6.0 in. wg or greater and that the manifold pressure is 3.5 in wg. If manifold pressure must be adjusted refer to Gas Valve Adjustment section. IMPORTANT: Unit power must be on for 24 hrs prior to start-up of compressors. Otherwise damage to compressors may result. Evaporator Fan — Fan belt and fixed pulleys are factoryinstalled. See Tables 3-38 for fan performance. Remove tape from fan pulley, and be sure that fans rotate in the proper direction. See Table 39 for motor limitations. See Tables 40A and 40B for air quantity limits. Static pressure drop for power exhaust is negligible. To alter fan performance, see Evaporator Fan Performance Adjustment section on page 130. 7 Table 3 — Fan Performance — 48AJ,AK020,025 and 48A2,A3020 Units AIRFLOW (CFM) 4,000 5,000 6,000 7,000 7,500 8,000 9,000 10,000 11,000 12,000 12,500 13,000 AIRFLOW (CFM) 4,000 5,000 6,000 7,000 7,500 8,000 9,000 10,000 11,000 12,000 12,500 13,000 0.2 Rpm Bhp 328 0.62 369 0.97 415 1.43 463 2.01 488 2.36 513 2.74 564 3.61 616 4.64 669 5.84 723 7.20 750 7.95 777 8.75 0.4 Rpm Bhp 406 0.84 439 1.19 477 1.65 519 2.25 541 2.60 564 2.98 612 3.87 661 4.91 711 6.11 762 7.49 788 8.25 814 9.05 0.6 Rpm Bhp 472 1.07 500 1.43 533 1.90 570 2.50 590 2.86 611 3.24 655 4.13 701 5.18 749 6.40 798 7.78 823 8.54 848 9.35 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 529 1.30 580 1.54 626 1.78 668 2.02 554 1.69 604 1.95 650 2.21 692 2.48 584 2.17 631 2.45 676 2.73 717 3.01 618 2.78 662 3.06 704 3.36 744 3.65 636 3.13 679 3.42 720 3.72 759 4.02 655 3.52 697 3.81 737 4.11 775 4.42 696 4.42 735 4.71 772 5.02 808 5.33 739 5.47 776 5.77 811 6.08 845 6.40 785 6.69 819 6.99 852 7.30 884 7.63 831 8.08 864 8.39 895 8.71 925 9.04 855 8.85 887 9.16 917 9.48 947 9.81 880 9.66 910 9.97 940 10.30 969 10.63 1.6 Rpm Bhp 708 2.27 731 2.74 756 3.30 782 3.96 796 4.33 811 4.74 843 5.65 878 6.72 915 7.96 955 9.37 976 10.15 997 10.97 1.8 Rpm Bhp 745 2.51 769 3.01 793 3.59 818 4.27 832 4.65 846 5.06 876 5.98 909 7.06 945 8.30 984 9.72 1004 10.49 1024 11.31 2.0 Rpm Bhp 780 2.76 804 3.28 828 3.88 852 4.58 866 4.96 879 5.38 909 6.32 940 7.40 975 8.65 1012 10.07 1031 10.84 1051 11.67 2.2 Rpm Bhp 814 3.01 837 3.55 861 4.17 885 4.89 898 5.28 912 5.71 940 6.66 971 7.75 1004 9.00 1039 10.42 1058 11.20 1077 12.03 2.4 Rpm Bhp 845 3.26 869 3.82 893 4.46 917 5.20 930 5.61 943 6.04 970 7.00 1000 8.10 1032 9.36 1066 10.79 1085 11.57 1103 12.40 2.6 Rpm Bhp 876 3.51 900 4.10 923 4.76 947 5.51 960 5.93 973 6.37 999 7.35 1028 8.46 1059 9.73 1093 11.16 1110 11.94 1129 12.77 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 905 3.76 934 4.02 961 4.28 987 4.54 929 4.37 958 4.64 985 4.92 1012 5.20 953 5.05 981 5.35 1009 5.65 1036 5.94 977 5.83 1005 6.14 1033 6.46 1059 6.78 989 6.25 1017 6.58 1045 6.90 1071 7.23 1002 6.70 1030 7.04 1057 7.37 1083 7.71 1028 7.69 1055 8.04 1082 8.39 1109 8.75 1056 8.82 1083 9.18 1109 9.54 1135 9.91 1086 10.09 1112 10.46 1138 10.84 1163 11.22 1119 11.53 1144 11.91 1169 12.30 1193 12.68 1136 12.32 1161 12.70 1185 13.09 — — 1154 13.15 1178 13.54 — — — — 3.6 Rpm Bhp 1013 4.80 1038 5.48 1062 6.24 1085 7.09 1097 7.56 1109 8.04 1134 9.10 1160 10.28 1188 11.60 — — — — — — 3.8 Rpm Bhp 1038 5.06 1063 5.76 1087 6.54 1110 7.41 1122 7.88 1134 8.38 1159 9.45 1185 10.65 — — — — — — — — 4.0 Rpm Bhp 1062 5.32 1087 6.04 1111 6.84 1135 7.73 1147 8.21 1159 8.72 1183 9.81 — — — — — — — — — — Table 4 — Fan Performance — 48AJ,AK027,030 and 48A2,A3025-030 Units AIRFLOW (CFM) 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 AIRFLOW (CFM) 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 0.2 Rpm Bhp 331 0.63 374 0.98 421 1.45 471 2.04 522 2.78 574 3.66 628 4.71 682 5.91 736 7.30 791 8.86 846 10.61 902 12.56 0.4 0.6 Rpm Bhp Rpm Bhp 408 0.85 474 1.08 443 1.20 503 1.45 482 1.68 538 1.93 526 2.28 576 2.54 572 3.03 619 3.29 621 3.92 664 4.19 671 4.97 711 5.25 722 6.19 759 6.48 774 7.59 809 7.88 827 9.16 860 9.46 880 10.93 912 11.24 934 12.89 964 13.21 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 531 1.31 581 1.55 627 1.79 670 2.03 558 1.70 607 1.96 653 2.23 695 2.49 589 2.20 636 2.47 680 2.75 721 3.04 623 2.81 668 3.10 710 3.39 749 3.69 662 3.57 704 3.86 743 4.16 781 4.47 704 4.47 743 4.77 780 5.08 815 5.40 748 5.54 784 5.84 819 6.15 853 6.47 795 6.77 828 7.08 861 7.40 893 7.72 842 8.18 874 8.49 905 8.82 935 9.15 891 9.78 922 10.09 951 10.42 979 10.75 941 11.56 970 11.88 998 12.21 1025 12.56 992 13.54 1020 13.87 1046 14.21 1072 14.55 1.6 Rpm Bhp 709 2.28 734 2.76 759 3.33 787 4.00 817 4.79 850 5.72 885 6.81 924 8.06 965 9.48 1007 11.10 1052 12.90 1098 14.91 1.8 Rpm Bhp 746 2.52 771 3.03 796 3.62 823 4.31 851 5.11 883 6.05 917 7.14 954 8.40 993 9.83 1034 11.45 1078 13.26 1122 15.26 2.0 Rpm Bhp 781 2.77 806 3.30 831 3.91 857 4.62 885 5.44 915 6.39 948 7.49 983 8.75 1021 10.19 1061 11.80 1103 13.62 1147 15.63 2.2 Rpm Bhp 815 3.02 839 3.57 864 4.20 890 4.93 917 5.76 946 6.73 978 7.84 1012 9.10 1048 10.54 1087 12.17 1128 13.98 1171 16.00 2.4 Rpm Bhp 847 3.27 871 3.84 896 4.49 921 5.24 948 6.09 976 7.07 1007 8.19 1040 9.47 1075 10.91 1113 12.54 1153 14.36 1194 16.38 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 906 3.77 935 4.03 962 4.29 988 4.55 931 4.39 960 4.66 987 4.94 1014 5.22 956 5.08 984 5.38 1012 5.68 1038 5.97 980 5.87 1009 6.18 1036 6.50 1063 6.82 1006 6.76 1034 7.09 1061 7.43 1088 7.76 1033 7.76 1061 8.11 1088 8.46 1114 8.82 1063 8.91 1089 9.27 1116 9.63 1141 10.00 1094 10.20 1120 10.57 1145 10.95 1170 11.33 1127 11.66 1152 12.04 1177 12.42 — — 1163 13.30 1187 13.68 — — — — — — — — — — — — — — — — — — — — 3.6 Rpm Bhp 1014 4.81 1039 5.50 1064 6.27 1088 7.14 1113 8.10 1139 9.17 1166 10.37 1195 11.71 — — — — — — — — 3.8 Rpm Bhp 1039 5.07 1064 5.78 1089 6.57 1114 7.45 1138 8.43 1164 9.52 1191 10.74 — — — — — — — — — — 4.0 Rpm Bhp 1063 5.33 1089 6.06 1114 6.87 1138 7.77 1163 8.77 1188 9.88 — — — — — — — — — — — — 2.6 Rpm Bhp 877 3.52 902 4.11 926 4.79 951 5.55 977 6.42 1005 7.42 1035 8.55 1067 9.83 1102 11.28 1138 12.91 1177 14.74 — — LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb 2. Conversion — Bhp to watts: Watts = NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. Bhp x 746 Motor efficiency 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. 8 Table 5 — Fan Performance — 48AJ,AK,A2,A3035 Units AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 10,500 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 10,500 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 0.2 Rpm 534 590 646 704 733 762 820 879 938 997 1056 1116 1145 Bhp 2.46 3.27 4.23 5.35 5.97 6.63 8.09 9.72 11.54 13.56 15.78 18.20 19.49 0.4 Rpm 584 635 687 742 769 797 853 909 967 1024 1082 1140 1170 2.2 Rpm 927 960 994 1030 1049 1069 1109 1152 1196 1243 1290 — — Bhp 5.81 6.89 8.09 9.42 10.14 10.90 12.55 14.38 16.41 18.63 21.06 — — Bhp 2.80 3.63 4.62 5.77 6.40 7.08 8.56 10.22 12.07 14.11 16.35 18.80 20.10 0.6 Rpm 630 677 726 778 804 830 884 939 995 1051 1107 1164 1193 2.4 Rpm 956 989 1023 1058 1077 1095 1135 1176 1220 1265 — — — Bhp 6.13 7.25 8.47 9.82 10.56 11.33 13.00 14.84 16.88 19.12 — — — Bhp 3.13 3.99 5.00 6.17 6.82 7.51 9.01 10.70 12.58 14.64 16.91 19.38 20.70 2.6 Rpm 985 1018 1051 1085 1103 1122 1160 1200 1243 1287 — — — Bhp 6.45 7.60 8.85 10.23 10.97 11.76 13.44 15.31 17.36 19.61 — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 674 3.48 716 3.82 756 4.16 793 4.50 718 4.35 757 4.72 794 5.08 830 5.45 764 5.38 800 5.76 835 6.15 869 6.54 812 6.57 846 6.97 879 7.38 911 7.78 837 7.23 870 7.64 902 8.05 933 8.46 863 7.93 894 8.35 925 8.77 955 9.19 915 9.46 944 9.90 973 10.34 1001 10.78 968 11.17 996 11.63 1023 12.09 1050 12.55 1022 13.07 1048 13.55 1074 14.03 1099 14.51 1076 15.16 1102 15.67 1126 16.17 1150 16.66 1132 17.45 1156 17.98 1179 18.50 1202 19.02 1188 19.95 1210 20.50 1233 21.05 1255 21.58 1216 21.28 1238 21.84 1260 22.40 1282 22.94 Rpm 829 864 902 942 963 984 1029 1076 1124 1174 1225 1276 — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 1012 6.76 1039 7.06 1065 7.37 1090 7.67 1045 7.94 1072 8.29 1098 8.63 1122 8.96 1078 9.23 1104 9.61 1130 9.98 1155 10.35 1112 10.64 1138 11.04 1163 11.44 1188 11.84 1129 11.39 1155 11.81 1180 12.23 1204 12.64 1147 12.18 1173 12.61 1197 13.04 1221 13.47 1185 13.89 1209 14.34 1233 14.79 1256 15.24 1224 15.77 1248 16.24 1271 16.70 1293 17.17 1266 17.84 1288 18.32 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Rpm 1114 1147 1179 1212 1228 1245 1279 — — — — — — 1.6 Bhp 4.83 5.81 6.93 8.19 8.88 9.62 11.22 13.01 14.98 17.16 19.53 22.11 — 1.8 Rpm 863 897 934 972 992 1013 1056 1102 1149 1197 1247 1298 — 3.6 Bhp 7.97 9.29 10.71 12.24 13.05 13.89 15.69 — — — — — — Bhp 5.17 6.18 7.31 8.60 9.30 10.04 11.66 13.46 15.46 17.65 20.04 22.64 — 2.0 Rpm 896 929 964 1002 1021 1041 1083 1127 1173 1220 1269 — — 3.8 Rpm 1138 1170 1203 1235 1251 1268 — — — — — — — Bhp 8.26 9.62 11.08 12.64 13.46 14.31 — — — — — — — Bhp 5.49 6.54 7.70 9.01 9.72 10.47 12.10 13.92 15.93 18.14 20.55 — — 4.0 Rpm 1161 1193 1226 1258 1274 1291 — — — — — — — Bhp 8.56 9.95 11.44 13.03 13.87 14.73 — — — — — — — Table 6 — Fan Performance — 48AJ,AK036 Units AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 0.2 Rpm 454 502 552 602 653 704 756 808 861 914 967 993 0.4 Bhp 2.15 2.90 3.81 4.89 6.15 7.60 9.24 11.10 13.18 15.49 18.03 19.40 Rpm 508 550 595 642 689 738 788 838 888 940 991 1017 Bhp 4.09 4.97 6.00 7.20 8.58 10.14 11.90 13.87 16.05 18.45 21.09 22.50 Rpm 734 759 788 821 856 895 935 976 1019 1063 1109 1131 1.2 Rpm 693 720 752 787 825 865 906 950 994 1039 1086 1109 1.4 2.2 Rpm 881 901 923 948 976 1008 1042 1078 1116 1156 1197 1218 Rpm 914 933 954 978 1005 1035 1068 1103 1140 1178 1218 1239 3.2 Rpm 1035 1053 1072 1092 1114 1139 1167 1198 1230 1265 — — 3.4 Bhp 8.63 9.69 10.89 12.25 13.79 15.53 17.47 19.63 22.00 24.61 — — Rpm 1062 1081 1099 1119 1140 1164 1191 1221 1253 1286 — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Rpm Bhp Rpm 773 4.95 811 796 5.85 832 823 6.92 857 854 8.16 886 887 9.57 918 924 11.18 952 962 12.99 989 1002 15.00 1028 1044 17.22 1068 1087 19.67 1110 1131 22.35 1153 1154 23.78 1175 0.8 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Bhp Rpm Bhp Rpm 6.74 946 7.21 977 7.72 965 8.20 995 8.85 985 9.35 1014 10.15 1007 10.66 1036 11.63 1033 12.16 1061 13.31 1062 13.86 1088 15.19 1093 15.76 1118 17.28 1127 17.86 1151 19.59 1163 20.19 1186 22.12 1200 22.74 1222 24.89 1240 25.52 1261 26.36 1260 27.00 1280 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Bhp Rpm Bhp Rpm 9.11 1089 9.60 1115 10.19 1108 10.70 1134 11.41 1126 11.94 1152 12.78 1145 13.33 1171 14.34 1166 14.90 1191 16.09 1189 16.67 1213 18.05 1215 18.64 1238 20.22 1244 20.82 1266 22.62 1274 23.23 1296 25.24 — — — — — — — — — — — LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. 1.0 Bhp 3.29 4.12 5.11 6.26 7.59 9.11 10.83 12.74 14.88 17.24 19.85 21.24 Rpm 650 680 715 752 792 834 878 922 968 1015 1062 1086 Bhp 5.39 6.31 7.39 8.64 10.08 11.71 13.53 15.57 17.81 20.28 22.98 24.42 Rpm 847 867 890 917 947 980 1016 1053 1093 1133 1175 1197 Bhp 7.68 8.69 9.86 11.19 12.70 14.41 16.32 18.45 20.79 23.36 26.17 27.66 Rpm 1006 1024 1043 1064 1088 1114 1143 1174 1208 1244 1281 — Bhp 10.09 11.21 12.47 13.88 15.46 17.24 19.23 21.43 23.85 — — — Rpm 1140 1159 1177 1196 1216 1237 1262 1288 — — — — 1.8 Bhp 4.52 5.40 6.45 7.67 9.07 10.66 12.44 14.43 16.63 19.06 21.72 23.14 2.4 Bhp 6.29 7.24 8.35 9.64 11.11 12.77 14.64 16.71 19.00 21.51 24.25 25.71 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 2.52 557 2.90 605 3.30 596 3.71 639 4.24 637 4.67 677 5.34 680 5.80 717 6.62 725 7.11 759 8.09 771 8.60 803 9.76 818 10.29 848 11.64 867 12.19 895 13.74 915 14.31 942 16.06 965 16.65 990 18.62 1015 19.23 1039 20.00 1040 20.61 1064 Bhp 3.69 4.54 5.55 6.73 8.08 9.63 11.36 13.30 15.46 17.85 20.47 21.87 2.0 2.8 Bhp 5.83 6.77 7.87 9.14 10.59 12.24 14.08 16.14 18.40 20.89 23.61 25.07 3.0 3.8 Bhp 8.15 9.19 10.37 11.71 13.24 14.97 16.89 19.03 21.40 23.98 26.81 — 4.0 Bhp 10.58 11.73 13.00 14.43 16.03 17.83 19.82 22.04 — — — — 2. Conversion — Bhp to watts: Bhp x 746 Motor efficiency 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. Watts = 9 Table 7 — Fan Performance — 48AJ,AK,A2,A3040 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 502 552 602 653 704 756 808 861 914 967 1020 1073 1127 Bhp 2.90 3.81 4.89 6.15 7.60 9.24 11.10 13.18 15.49 18.03 20.82 23.87 27.18 0.4 Rpm 550 595 642 689 738 788 838 888 940 991 1043 1095 1147 2.2 Rpm 901 923 948 976 1008 1042 1078 1116 1156 1197 1239 — — Bhp 7.24 8.35 9.64 11.11 12.77 14.64 16.71 19.00 21.51 24.25 27.24 — — Bhp 3.30 4.24 5.34 6.62 8.09 9.76 11.64 13.74 16.06 18.62 21.43 24.50 27.82 0.6 Rpm 596 637 680 725 771 818 867 915 965 1015 1066 1117 1168 2.4 Rpm 933 954 978 1005 1035 1068 1103 1140 1178 1218 1260 — — Bhp 7.72 8.85 10.15 11.63 13.31 15.19 17.28 19.59 22.12 24.89 27.89 — — Bhp 3.71 4.67 5.80 7.11 8.60 10.29 12.19 14.31 16.65 19.23 22.06 25.14 28.48 2.6 Rpm 965 985 1007 1033 1062 1093 1127 1163 1200 1240 1280 — — Bhp 8.20 9.35 10.66 12.16 13.86 15.76 17.86 20.19 22.74 25.52 28.55 — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 639 4.12 680 4.54 720 4.97 759 5.40 677 5.11 715 5.55 752 6.00 788 6.45 717 6.26 752 6.73 787 7.20 821 7.67 759 7.59 792 8.08 825 8.58 856 9.07 803 9.11 834 9.63 865 10.14 895 10.66 848 10.83 878 11.36 906 11.90 935 12.44 895 12.74 922 13.30 950 13.87 976 14.43 942 14.88 968 15.46 994 16.05 1019 16.63 990 17.24 1015 17.85 1039 18.45 1063 19.06 1039 19.85 1062 20.47 1086 21.09 1109 21.72 1088 22.69 1111 23.33 1133 23.97 1155 24.62 1138 25.79 1159 26.44 1180 27.11 1201 27.77 1188 29.15 — — — — — — Rpm 796 823 854 887 924 962 1002 1044 1087 1131 1176 1222 — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 995 8.69 1024 9.19 1053 9.69 1081 10.19 1014 9.86 1043 10.37 1072 10.89 1099 11.41 1036 11.19 1064 11.71 1092 12.25 1119 12.78 1061 12.70 1088 13.24 1114 13.79 1140 14.34 1088 14.41 1114 14.97 1139 15.53 1164 16.09 1118 16.32 1143 16.89 1167 17.47 1191 18.05 1151 18.45 1174 19.03 1198 19.63 1221 20.22 1186 20.79 1208 21.40 1230 22.00 1253 22.62 1222 23.36 1244 23.98 1265 24.61 1286 25.24 1261 26.17 1281 26.81 — — — — — — — — — — — — — — — — — — — — — — — — — — — — Rpm 1108 1126 1145 1166 1189 1215 1244 1274 — — — — — 1.6 Bhp 5.85 6.92 8.16 9.57 11.18 12.99 15.00 17.22 19.67 22.35 25.27 28.45 — 1.8 Rpm 832 857 886 918 952 989 1028 1068 1110 1153 1197 1242 — 3.6 Bhp 10.70 11.94 13.33 14.90 16.67 18.64 20.82 23.23 — — — — — Bhp 6.31 7.39 8.64 10.08 11.71 13.53 15.57 17.81 20.28 22.98 25.92 29.12 — 2.0 Rpm 867 890 917 947 980 1016 1053 1093 1133 1175 1219 — — 3.8 Rpm 1134 1152 1171 1191 1213 1238 1266 1296 — — — — — Bhp 11.21 12.47 13.88 15.46 17.24 19.23 21.43 23.85 — — — — — Bhp 6.77 7.87 9.14 10.59 12.24 14.08 16.14 18.40 20.89 23.61 26.58 — — 4.0 Rpm 1159 1177 1196 1216 1237 1262 1288 — — — — — — Bhp 11.73 13.00 14.43 16.03 17.83 19.82 22.04 — — — — — — Table 8 — Fan Performance — 48AJ,AK041 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 502 552 602 653 704 756 808 861 914 967 1020 1073 1127 0.4 Bhp 2.90 3.81 4.89 6.15 7.60 9.24 11.10 13.18 15.49 18.03 20.82 23.87 27.18 Rpm 550 595 642 689 738 788 838 888 940 991 1043 1095 1147 1.2 Rpm 720 752 787 825 865 906 950 994 1039 1086 1133 1180 — 1.4 Bhp 4.97 6.00 7.20 8.58 10.14 11.90 13.87 16.05 18.45 21.09 23.97 27.11 — Rpm 759 788 821 856 895 935 976 1019 1063 1109 1155 1201 — 2.2 Rpm 901 923 948 976 1008 1042 1078 1116 1156 1197 1239 — — 2.4 Bhp 7.24 8.35 9.64 11.11 12.77 14.64 16.71 19.00 21.51 24.25 27.24 — — Rpm 933 954 978 1005 1035 1068 1103 1140 1178 1218 1260 — — 3.2 Rpm 1053 1072 1092 1114 1139 1167 1198 1230 1265 — — — — 3.4 Bhp 9.69 10.89 12.25 13.79 15.53 17.47 19.63 22.00 24.61 — — — — Rpm 1081 1099 1119 1140 1164 1191 1221 1253 1286 — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 3.30 596 3.71 639 4.24 637 4.67 677 5.34 680 5.80 717 6.62 725 7.11 759 8.09 771 8.60 803 9.76 818 10.29 848 11.64 867 12.19 895 13.74 915 14.31 942 16.06 965 16.65 990 18.62 1015 19.23 1039 21.43 1066 22.06 1088 24.50 1117 25.14 1138 27.82 1168 28.48 1188 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Bhp Rpm Bhp Rpm 5.40 796 5.85 832 6.45 823 6.92 857 7.67 854 8.16 886 9.07 887 9.57 918 10.66 924 11.18 952 12.44 962 12.99 989 14.43 1002 15.00 1028 16.63 1044 17.22 1068 19.06 1087 19.67 1110 21.72 1131 22.35 1153 24.62 1176 25.27 1197 27.77 1222 28.45 1242 — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Bhp Rpm Bhp Rpm 7.72 965 8.20 995 8.85 985 9.35 1014 10.15 1007 10.66 1036 11.63 1033 12.16 1061 13.31 1062 13.86 1088 15.19 1093 15.76 1118 17.28 1127 17.86 1151 19.59 1163 20.19 1186 22.12 1200 22.74 1222 24.89 1240 25.52 1261 27.89 1280 28.55 — — — — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Bhp Rpm Bhp Rpm 10.19 1108 10.70 1134 11.41 1126 11.94 1152 12.78 1145 13.33 1171 14.34 1166 14.90 1191 16.09 1189 16.67 1213 18.05 1215 18.64 1238 20.22 1244 20.82 1266 22.62 1274 23.23 1296 25.24 — — — — — — — — — — — — — — — — — — — 10 0.8 1.0 Bhp 4.12 5.11 6.26 7.59 9.11 10.83 12.74 14.88 17.24 19.85 22.69 25.79 29.15 Rpm 680 715 752 792 834 878 922 968 1015 1062 1111 1159 — Bhp 6.31 7.39 8.64 10.08 11.71 13.53 15.57 17.81 20.28 22.98 25.92 29.12 — Rpm 867 890 917 947 980 1016 1053 1093 1133 1175 1219 — — Bhp 8.69 9.86 11.19 12.70 14.41 16.32 18.45 20.79 23.36 26.17 — — — Rpm 1024 1043 1064 1088 1114 1143 1174 1208 1244 1281 — — — Bhp 11.21 12.47 13.88 15.46 17.24 19.23 21.43 23.85 — — — — — Rpm 1159 1177 1196 1216 1237 1262 1288 — — — — — — 1.8 Bhp 4.54 5.55 6.73 8.08 9.63 11.36 13.30 15.46 17.85 20.47 23.33 26.44 — 2.0 2.8 Bhp 6.77 7.87 9.14 10.59 12.24 14.08 16.14 18.40 20.89 23.61 26.58 — — 3.0 3.8 Bhp 9.19 10.37 11.71 13.24 14.97 16.89 19.03 21.40 23.98 26.81 — — — 4.0 Bhp 11.73 13.00 14.43 16.03 17.83 19.82 22.04 — — — — — — Table 9 — Fan Performance — 48AJ,AK,A2,A3050 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 512 561 611 662 714 766 819 872 925 979 1032 1086 1140 0.4 Bhp 2.98 3.90 5.00 6.27 7.74 9.41 11.29 13.40 15.74 18.32 21.15 24.24 27.60 Rpm 560 604 651 699 748 798 848 899 951 1003 1055 1108 1161 2.2 Rpm 907 930 955 984 1016 1050 1087 1126 1166 1208 1250 1294 — 0.6 Bhp 3.38 4.33 5.45 6.75 8.24 9.93 11.84 13.96 16.32 18.92 21.77 24.88 28.25 Rpm 604 645 689 734 780 828 877 926 976 1027 1078 1129 1181 2.4 Bhp 7.34 8.46 9.76 11.25 12.93 14.82 16.92 19.23 21.78 24.56 27.59 30.87 — Rpm 940 961 985 1012 1043 1076 1111 1149 1188 1229 1271 — — 0.8 Bhp 3.79 4.77 5.91 7.23 8.75 10.46 12.39 14.54 16.91 19.53 22.40 25.52 28.92 Rpm 647 685 725 768 812 858 905 953 1001 1051 1100 1151 1202 2.6 Bhp 7.81 8.95 10.27 11.77 13.47 15.38 17.49 19.83 22.40 25.20 28.25 — — Rpm 971 991 1014 1040 1069 1101 1136 1172 1210 1250 1291 — — 2.8 Bhp 8.30 9.46 10.79 12.30 14.02 15.94 18.07 20.43 23.01 25.84 28.91 — — Rpm 1001 1021 1043 1068 1095 1126 1159 1195 1232 1271 — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.0 1.2 1.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 4.20 688 4.62 728 5.05 766 5.49 5.20 723 5.65 760 6.10 796 6.55 6.37 761 6.84 795 7.31 829 7.79 7.72 801 8.21 833 8.71 865 9.20 9.26 843 9.77 873 10.29 903 10.81 11.00 887 11.54 916 12.08 944 12.62 12.95 932 13.51 959 14.07 986 14.63 15.11 979 15.70 1004 16.28 1029 16.87 17.51 1026 18.12 1050 18.72 1074 19.33 20.15 1074 20.77 1097 21.40 1120 22.03 23.04 1123 23.68 1145 24.33 1166 24.98 26.18 1172 26.84 1193 27.51 1214 28.18 29.59 1222 30.27 1242 30.95 1262 31.64 Rpm 803 831 861 895 932 971 1012 1054 1097 1142 1188 1234 1281 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.0 3.2 3.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 8.79 1030 9.29 1059 9.79 1086 10.29 9.97 1050 10.48 1078 11.00 1105 11.52 11.31 1071 11.84 1098 12.37 1125 12.91 12.84 1095 13.38 1121 13.93 1147 14.49 14.57 1121 15.13 1147 15.69 1172 16.26 16.51 1151 17.08 1175 17.66 1199 18.24 18.66 1183 19.25 1206 19.84 1229 20.44 21.03 1217 21.64 1239 22.25 1261 22.86 23.64 1253 24.26 1275 24.89 1296 25.52 26.48 1291 27.12 — — — — — — — — — — — — — — — — — — — — — — — — — Rpm 1113 1131 1151 1172 1196 1223 1252 1283 — — — — — 1.6 1.8 Bhp 5.94 7.02 8.27 9.71 11.33 13.16 15.20 17.46 19.94 22.66 25.63 28.85 32.33 Rpm 839 864 893 925 960 998 1037 1078 1121 1164 1209 1255 — Bhp 10.80 12.05 13.46 15.05 16.83 18.83 21.04 23.48 — — — — — Rpm 1139 1157 1177 1197 1220 1246 1274 — — — — — — 3.6 2.0 Bhp 6.40 7.49 8.76 10.21 11.86 13.71 15.77 18.05 20.55 23.29 26.28 29.52 — Rpm 874 897 925 955 988 1024 1062 1102 1143 1186 1230 1275 — Bhp 11.31 12.58 14.01 15.61 17.41 19.42 21.64 — — — — — — Rpm 1164 1183 1202 1222 1244 1269 1296 — — — — — — 3.8 Bhp 6.86 7.97 9.26 10.73 12.39 14.26 16.34 18.64 21.17 23.93 26.93 30.19 — 4.0 Bhp 11.83 13.12 14.56 16.18 18.00 20.02 22.25 — — — — — — Table 10 — Fan Performance — 48AJ,AK051 Units AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 0.2 Rpm 419 476 506 536 566 597 628 659 691 723 755 787 819 851 883 0.4 Bhp 2.89 4.33 5.21 6.18 7.28 8.48 9.80 11.25 12.82 14.53 16.37 18.35 20.48 22.75 25.17 Rpm 483 534 561 588 617 645 674 704 734 764 794 825 856 887 918 1.2 Rpm 673 714 735 758 781 804 829 853 879 905 931 958 985 1012 1040 1.4 Bhp 6.60 8.24 9.22 10.30 11.50 12.82 14.27 15.85 17.58 19.44 21.46 23.62 25.93 28.40 31.02 Rpm 711 751 772 793 816 839 862 886 911 936 961 987 1014 1041 1068 Bhp 10.82 12.78 13.88 15.06 16.36 17.76 19.28 20.94 22.72 24.65 26.73 28.95 31.33 33.87 36.58 Rpm 876 911 929 948 968 989 1010 1032 1054 1076 1099 1123 1147 1171 1196 2.2 Rpm 846 881 900 920 940 961 983 1005 1027 1050 1073 1097 1122 1146 1171 2.4 3.2 Rpm 988 1019 1036 1054 1073 1092 1112 1132 1153 1174 1196 — — — — Rpm 1014 1045 1061 1079 1097 1116 1135 1156 1176 1197 — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Bhp Rpm Bhp Rpm 7.42 747 8.26 782 9.12 786 10.02 819 10.11 806 11.03 839 11.21 827 12.15 859 12.43 849 13.38 881 13.76 871 14.73 902 15.23 894 16.21 925 16.82 918 17.82 948 18.56 942 19.57 971 20.44 966 21.45 995 22.47 991 23.50 1019 24.64 1016 25.69 1044 26.97 1042 28.03 1069 29.46 1068 30.54 1095 32.11 1095 33.21 1121 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Rpm Bhp Rpm 906 12.56 934 939 14.67 967 957 15.82 984 976 17.07 1003 996 18.41 1022 1016 19.86 1042 1036 21.42 1062 1058 23.11 1083 1080 24.92 1105 1102 26.88 1126 1124 28.97 1149 1147 31.22 1172 1171 33.63 1195 1195 36.19 — — — — 0.8 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Bhp Rpm Bhp Rpm 16.09 1039 16.98 1063 18.51 1069 19.48 1093 19.80 1086 20.81 1109 21.17 1103 22.21 1126 22.63 1121 23.70 1144 24.17 1140 25.28 1162 25.83 1159 26.95 1181 27.60 1178 28.74 — 29.48 1199 30.65 — 31.50 — — — — — — — — — — — — — — — — — — — — — — — 1.0 Bhp 5.00 6.56 7.50 8.56 9.73 11.02 12.45 14.00 15.69 17.52 19.49 21.60 23.87 26.28 28.84 Rpm 632 674 697 720 744 768 793 819 845 872 899 927 954 983 1011 Bhp 9.10 10.92 11.97 13.11 14.35 15.72 17.21 18.84 20.60 22.50 24.55 26.76 29.11 31.63 34.31 Rpm 815 851 870 890 911 932 954 977 1000 1023 1047 1071 1096 1121 1147 Bhp 13.44 15.62 16.81 18.08 19.45 20.92 22.51 24.21 26.04 28.01 30.13 32.39 34.80 — — Rpm 961 993 1011 1029 1048 1067 1087 1108 1129 1151 1173 1195 — — — Bhp 17.88 20.45 21.82 23.26 24.78 26.38 28.09 — — — — — — — — Rpm 1087 1117 1133 1149 1167 1185 — — — — — — — — — 1.8 Bhp 5.79 7.39 8.34 9.41 10.59 11.90 13.34 14.91 16.62 18.47 20.47 22.61 24.90 27.34 29.94 2.0 2.8 Bhp 11.69 13.72 14.85 16.06 17.38 18.80 20.34 22.01 23.81 25.76 27.84 30.08 32.47 35.02 37.74 3.4 Bhp 15.21 17.54 18.80 20.13 21.56 23.08 24.71 26.46 28.33 30.33 32.47 — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 3.54 538 4.25 587 5.04 585 5.78 632 5.94 610 6.70 655 6.96 636 7.74 680 8.09 662 8.90 704 9.34 689 10.17 730 10.71 717 11.58 756 12.21 745 13.11 783 13.84 773 14.77 810 15.60 802 16.57 838 17.49 831 18.51 866 19.53 861 20.59 894 21.71 890 22.81 923 24.04 920 25.19 952 26.52 951 27.72 982 Bhp 9.96 11.85 12.92 14.08 15.35 16.73 18.24 19.88 21.65 23.57 25.63 27.84 30.21 32.74 35.44 3.0 3.8 Bhp 14.32 16.58 17.80 19.11 20.50 22.00 23.60 25.33 27.18 29.17 31.29 33.56 — — — 4.0 Bhp 18.77 21.43 22.84 24.31 25.86 27.49 — — — — — — — — — 2. Conversion — Bhp to watts: LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb Watts = Bhp x 746 Motor efficiency 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. 11 Table 11 — Fan Performance — 48AJ,AK,A2,A3060 Units AIRFLOW (Cfm) 12,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 26,000 27,000 AIRFLOW (Cfm) 12,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 26,000 27,000 0.2 Rpm Bhp 476 4.33 536 6.19 566 7.28 597 8.48 628 9.80 659 11.25 691 12.82 723 14.53 755 16.37 787 18.35 819 20.48 851 22.75 883 25.17 916 27.76 948 30.49 0.4 Rpm Bhp 534 5.04 588 6.96 617 8.09 645 9.34 674 10.71 704 12.21 734 13.84 764 15.60 794 17.49 825 19.53 856 21.71 887 24.04 918 26.52 950 29.15 981 31.95 0.6 Rpm Bhp 585 5.78 636 7.74 662 8.90 689 10.17 717 11.58 745 13.11 773 14.77 802 16.57 831 18.51 861 20.59 890 22.81 920 25.19 951 27.72 981 30.40 1012 33.24 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 632 6.56 674 7.39 714 8.24 751 9.12 680 8.56 720 9.41 758 10.30 793 11.21 704 9.73 744 10.59 781 11.50 816 12.42 730 11.02 768 11.90 804 12.82 839 13.76 756 12.45 793 13.34 829 14.27 862 15.23 783 14.00 819 14.91 853 15.85 886 16.82 810 15.69 845 16.62 879 17.58 911 18.56 838 17.52 872 18.47 905 19.44 936 20.44 866 19.49 899 20.47 931 21.46 961 22.47 894 21.60 927 22.61 958 23.62 987 24.64 923 23.87 954 24.90 985 25.93 1014 26.97 952 26.28 983 27.34 1012 28.40 1041 29.46 982 28.84 1011 29.94 1040 31.02 1068 32.11 1011 31.57 1040 32.70 1068 33.81 1095 34.92 1041 34.46 1070 35.62 1097 36.76 1123 37.90 1.6 Rpm Bhp 786 10.02 827 12.15 849 13.38 871 14.73 894 16.21 918 17.82 942 19.57 966 21.45 991 23.50 1016 25.69 1042 28.03 1068 30.54 1095 33.21 1122 36.04 1149 39.04 1.8 Rpm Bhp 819 10.93 859 13.11 881 14.36 902 15.72 925 17.21 948 18.84 971 20.60 995 22.50 1019 24.55 1044 26.76 1069 29.11 1095 31.63 1121 34.31 1147 37.16 1174 40.18 2.0 Rpm Bhp 851 11.85 890 14.08 911 15.35 932 16.73 954 18.24 977 19.88 1000 21.65 1023 23.57 1047 25.63 1071 27.84 1096 30.21 1121 32.74 1147 35.44 1172 38.30 1199 41.34 2.2 Rpm Bhp 881 12.78 920 15.06 940 16.36 961 17.76 983 19.28 1005 20.94 1027 22.72 1050 24.65 1073 26.73 1097 28.95 1122 31.33 1146 33.87 1171 36.58 1197 39.46 — — 2.4 Rpm Bhp 911 13.72 948 16.06 968 17.38 989 18.80 1010 20.34 1032 22.01 1054 23.81 1076 25.76 1099 27.84 1123 30.08 1147 32.47 1171 35.02 1196 37.74 — — — — 2.6 Rpm Bhp 939 14.67 976 17.07 996 18.41 1016 19.86 1036 21.42 1058 23.11 1080 24.92 1102 26.88 1124 28.97 1147 31.22 1171 33.63 1195 36.19 — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 967 15.62 993 16.58 1019 17.54 1045 18.51 1003 18.08 1029 19.11 1054 20.13 1079 21.17 1022 19.45 1048 20.50 1073 21.56 1097 22.63 1042 20.92 1067 22.00 1092 23.08 1116 24.17 1062 22.51 1087 23.60 1112 24.71 1135 25.83 1083 24.21 1108 25.33 1132 26.46 1156 27.60 1105 26.04 1129 27.18 1153 28.33 1176 29.48 1126 28.01 1151 29.17 1174 30.33 1197 31.50 1149 30.13 1173 31.29 1196 32.47 — — 1172 32.39 1195 33.56 — — — — 1195 34.80 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 3.6 Rpm Bhp 1069 19.48 1103 22.21 1121 23.70 1140 25.28 1159 26.95 1178 28.74 1199 30.65 — — — — — — — — — — — — — — — — 3.8 Rpm Bhp 1093 20.45 1126 23.26 1144 24.78 1162 26.38 1181 28.09 — — — — — — — — — — — — — — — — — — — — 4.0 Rpm Bhp 1117 21.43 1149 24.31 1167 25.86 1185 27.49 — — — — — — — — — — — — — — — — — — — — — — Table 12 — Fan Performance — 50AJ,AK020,025 and 50A2,A3020 Units AIRFLOW (CFM) 4,000 5,000 6,000 7,000 7,500 8,000 9,000 10,000 11,000 12,000 12,500 13,000 AIRFLOW (CFM) 4,000 5,000 6,000 7,000 7,500 8,000 9,000 10,000 11,000 12,000 12,500 13,000 0.2 Rpm Bhp 311 0.54 347 0.84 387 1.25 430 1.77 452 2.07 474 2.41 519 3.19 565 4.10 611 5.17 658 6.39 681 7.06 705 7.77 0.4 Rpm Bhp 390 0.71 417 1.02 450 1.43 488 1.96 507 2.27 528 2.61 570 3.39 613 4.31 657 5.37 702 6.60 725 7.27 748 7.98 0.6 Rpm Bhp 457 0.88 480 1.21 507 1.63 540 2.17 557 2.48 576 2.82 614 3.60 655 4.53 697 5.60 741 6.83 763 7.50 785 8.21 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 515 1.05 567 1.21 613 1.38 656 1.55 536 1.40 587 1.59 633 1.78 676 1.97 560 1.84 609 2.05 654 2.26 696 2.47 588 2.38 634 2.61 677 2.83 718 3.06 604 2.70 648 2.93 690 3.16 730 3.40 620 3.04 663 3.28 704 3.52 743 3.76 656 3.83 696 4.07 734 4.32 771 4.57 694 4.76 731 5.00 767 5.26 802 5.51 734 5.84 769 6.08 803 6.34 836 6.60 776 7.07 809 7.32 841 7.58 872 7.85 797 7.74 830 8.00 861 8.26 891 8.53 819 8.46 850 8.71 881 8.98 910 9.25 1.6 Rpm Bhp 696 1.71 716 2.16 735 2.68 756 3.29 768 3.63 780 4.00 806 4.82 835 5.78 868 6.87 902 8.12 920 8.80 939 9.53 1.8 Rpm Bhp 733 1.88 753 2.34 773 2.88 793 3.51 804 3.87 816 4.24 840 5.08 868 6.04 899 7.15 932 8.40 949 9.08 967 9.81 2.0 Rpm Bhp 768 2.04 788 2.52 808 3.09 828 3.74 839 4.10 850 4.48 873 5.34 900 6.31 929 7.42 960 8.68 977 9.37 994 10.10 2.2 Rpm Bhp 802 2.21 822 2.71 842 3.29 862 3.96 872 4.33 883 4.73 905 5.60 931 6.58 958 7.70 989 8.97 1005 9.66 1021 10.39 2.4 Rpm Bhp 833 2.38 854 2.89 874 3.50 894 4.19 904 4.56 914 4.97 936 5.85 961 6.85 987 7.99 1016 9.26 1032 9.95 1048 10.69 2.6 Rpm Bhp 864 2.55 885 3.08 905 3.70 924 4.41 934 4.79 945 5.21 966 6.11 990 7.13 1015 8.27 1043 9.55 1058 10.25 1074 10.99 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 893 2.71 921 2.88 949 3.06 975 3.23 914 3.26 943 3.45 970 3.64 997 3.82 934 3.90 963 4.10 991 4.31 1017 4.51 954 4.63 983 4.85 1010 5.07 1037 5.29 964 5.02 993 5.25 1020 5.48 1047 5.71 974 5.45 1003 5.68 1030 5.92 1057 6.16 995 6.37 1023 6.62 1051 6.88 1077 7.13 1018 7.40 1046 7.67 1073 7.94 1099 8.21 1043 8.55 1070 8.84 1096 9.12 1122 9.41 1070 9.85 1096 10.14 1121 10.44 1146 10.73 1084 10.55 1110 10.85 1135 11.15 1159 11.45 1099 11.29 1124 11.59 1149 11.90 1173 12.20 3.6 Rpm Bhp 1001 3.40 1023 4.01 1043 4.71 1063 5.51 1073 5.94 1083 6.39 1103 7.38 1124 8.48 1147 9.69 1171 11.03 1183 11.75 1197 12.51 3.8 Rpm Bhp 1026 3.58 1048 4.20 1069 4.91 1089 5.72 1099 6.16 1108 6.63 1129 7.64 1149 8.75 1171 9.98 1195 11.33 — — — — 4.0 Rpm Bhp 1050 3.75 1072 4.39 1093 5.12 1113 5.94 1123 6.39 1133 6.87 1153 7.89 1174 9.02 1195 10.26 — — — — — — LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb 2. Conversion — Bhp to watts: Watts = NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. Bhp x 746 Motor efficiency 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. 12 Table 13 — Fan Performance — 50AJ,AK027,030 and 50A2,A3025-030 Units AIRFLOW (CFM) 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 AIRFLOW (CFM) 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 0.2 Rpm Bhp 314 0.54 352 0.85 394 1.26 438 1.79 483 2.44 530 3.23 577 4.15 625 5.22 674 6.45 722 7.85 771 9.41 821 11.15 0.4 Rpm Bhp 394 0.72 422 1.03 456 1.45 495 1.98 536 2.64 579 3.43 624 4.36 669 5.44 715 6.67 762 8.07 810 9.64 857 11.38 0.6 Rpm Bhp 460 0.89 484 1.22 513 1.65 546 2.19 583 2.85 623 3.65 665 4.58 708 5.67 753 6.90 798 8.30 844 9.88 890 11.62 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 517 1.05 569 1.22 615 1.39 658 1.55 540 1.42 590 1.61 636 1.79 678 1.98 565 1.86 613 2.07 658 2.28 700 2.49 594 2.41 640 2.64 682 2.86 723 3.09 628 3.08 670 3.32 710 3.55 749 3.80 664 3.88 704 4.12 741 4.37 778 4.62 703 4.82 740 5.06 776 5.32 810 5.58 744 5.91 779 6.16 813 6.41 845 6.68 787 7.15 820 7.40 851 7.67 882 7.93 831 8.55 862 8.81 892 9.08 921 9.35 875 10.13 905 10.39 934 10.66 962 10.94 921 11.88 949 12.14 977 12.42 1004 12.70 1.6 Rpm Bhp 697 1.72 718 2.17 739 2.70 761 3.32 786 4.04 813 4.88 843 5.84 877 6.95 912 8.21 950 9.63 989 11.22 1030 12.99 1.8 Rpm Bhp 734 1.88 755 2.35 776 2.90 798 3.54 821 4.28 847 5.13 876 6.11 907 7.22 941 8.49 977 9.92 1015 11.51 1055 13.28 2.0 Rpm Bhp 769 2.05 791 2.54 811 3.11 833 3.77 855 4.52 880 5.39 907 6.38 937 7.50 970 8.78 1005 10.21 1041 11.81 1080 13.58 2.2 Rpm Bhp 803 2.22 824 2.72 845 3.31 866 3.99 888 4.77 912 5.65 938 6.65 967 7.78 998 9.07 1031 10.50 1067 12.10 1104 13.88 2.4 Rpm Bhp 835 2.38 856 2.91 877 3.52 898 4.21 919 5.01 942 5.90 968 6.92 995 8.07 1025 9.35 1058 10.80 1092 12.41 1128 14.19 2.6 Rpm Bhp 865 2.55 887 3.09 908 3.72 928 4.43 950 5.25 972 6.16 997 7.19 1023 8.35 1052 9.65 1083 11.10 1117 12.71 1152 14.50 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 894 2.72 923 2.89 950 3.06 976 3.24 916 3.28 945 3.46 972 3.65 999 3.83 937 3.92 966 4.12 993 4.32 1020 4.53 958 4.66 986 4.88 1014 5.10 1041 5.31 979 5.49 1007 5.72 1035 5.96 1061 6.20 1001 6.42 1029 6.67 1056 6.93 1083 7.18 1025 7.46 1052 7.73 1079 8.00 1105 8.27 1051 8.63 1077 8.92 1103 9.20 1129 9.49 1078 9.94 1104 10.24 1130 10.54 1154 10.83 1109 11.40 1133 11.71 1158 12.01 1182 12.32 1141 13.02 1165 13.33 1188 13.65 — — 1175 14.81 1198 15.13 — — — — 3.6 Rpm Bhp 1002 3.41 1024 4.02 1046 4.73 1067 5.53 1087 6.43 1108 7.43 1130 8.54 1154 9.77 1179 11.13 — — — — — — 3.8 Rpm Bhp 1027 3.58 1049 4.21 1071 4.93 1092 5.75 1113 6.67 1134 7.69 1155 8.81 1178 10.06 — — — — — — — — 4.0 Rpm Bhp 1051 3.76 1074 4.40 1096 5.14 1116 5.97 1137 6.90 1158 7.94 1180 9.08 — — — — — — — — — — Table 14 — Fan Performance — 50AJ,AKA2,A3035 Units AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 10,500 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 10,500 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 0.2 Rpm Bhp 503 1.96 553 2.62 605 3.39 657 4.29 684 4.80 710 5.33 764 6.52 818 7.85 872 9.33 926 10.98 980 12.79 1035 14.77 1062 15.83 0.4 Rpm Bhp 553 2.22 599 2.89 647 3.68 696 4.61 721 5.12 747 5.66 798 6.86 849 8.21 901 9.71 954 11.37 1007 13.20 1060 15.19 1087 16.25 0.6 Rpm Bhp 601 2.47 643 3.16 687 3.97 733 4.91 757 5.43 781 5.99 830 7.21 880 8.57 930 10.09 981 11.76 1033 13.60 1085 15.61 1111 16.68 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 646 2.72 689 2.97 730 3.22 768 3.46 684 3.43 724 3.70 763 3.97 799 4.23 726 4.26 763 4.55 798 4.83 833 5.12 769 5.22 803 5.52 837 5.82 870 6.12 791 5.75 825 6.06 857 6.37 889 6.68 814 6.31 847 6.63 878 6.95 909 7.26 861 7.54 891 7.88 921 8.21 950 8.54 909 8.92 938 9.27 966 9.62 993 9.97 958 10.45 985 10.82 1012 11.19 1037 11.55 1008 12.15 1033 12.53 1059 12.91 1083 13.28 1058 14.00 1082 14.40 1106 14.79 1130 15.18 1109 16.03 1132 16.44 1155 16.84 1178 17.25 1134 17.10 1157 17.52 1180 17.94 1202 18.35 1.6 Rpm Bhp 804 3.70 834 4.50 867 5.40 901 6.42 920 6.98 939 7.58 978 8.87 1020 10.31 1063 11.91 1108 13.66 1153 15.57 1200 17.65 1224 18.76 1.8 Rpm Bhp 839 3.94 868 4.76 899 5.68 932 6.72 950 7.29 968 7.89 1006 9.20 1046 10.66 1088 12.27 1131 14.03 1176 15.96 1222 18.05 1245 19.17 2.0 Rpm Bhp 872 4.17 901 5.02 930 5.96 962 7.02 979 7.60 997 8.21 1033 9.53 1072 11.00 1113 12.63 1155 14.40 1199 16.35 1243 18.46 1266 19.58 2.2 Rpm Bhp 903 4.40 932 5.27 961 6.24 992 7.32 1008 7.90 1025 8.52 1060 9.86 1097 11.35 1137 12.98 1178 14.77 1221 16.73 1265 18.85 1287 19.98 2.4 Rpm Bhp 933 4.62 962 5.52 990 6.52 1020 7.62 1036 8.21 1052 8.84 1086 10.19 1122 11.69 1161 13.34 1201 15.15 1243 17.11 1286 19.25 — — 2.6 Rpm Bhp 962 4.84 991 5.77 1019 6.79 1048 7.91 1063 8.51 1079 9.15 1112 10.52 1147 12.03 1184 13.69 1223 15.51 1264 17.50 — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 990 5.06 1017 5.27 1043 5.48 1068 5.69 1019 6.02 1045 6.26 1071 6.50 1097 6.73 1047 7.06 1073 7.33 1099 7.59 1125 7.85 1075 8.20 1102 8.49 1127 8.78 1152 9.07 1090 8.82 1116 9.12 1142 9.41 1166 9.71 1105 9.46 1131 9.77 1156 10.08 1181 10.39 1137 10.85 1162 11.17 1187 11.50 1211 11.82 1171 12.37 1195 12.72 1219 13.06 1242 13.40 1208 14.05 1231 14.41 1253 14.76 1276 15.12 1246 15.88 1268 16.25 1289 16.62 — — 1286 17.88 — — — — — — — — — — — — — — — — — — — — — — 3.6 Rpm Bhp 1092 5.89 1121 6.96 1149 8.11 1177 9.35 1191 10.01 1205 10.69 1234 12.15 1265 13.74 1298 15.47 — — — — — — — — 3.8 Rpm Bhp 1116 6.09 1145 7.19 1173 8.37 1201 9.63 1214 10.30 1228 10.99 1257 12.47 1287 14.08 — — — — — — — — — — 4.0 Rpm Bhp 1139 6.28 1168 7.42 1196 8.62 1224 9.91 1238 10.59 1252 11.29 1280 12.79 — — — — — — — — — — — — LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb 2. Conversion — Bhp to watts: NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. Watts = 13 Bhp x 746 Motor efficiency Table 15 — Fan Performance — 50AJ,AK036 Units AIRFLOW (Cfm) 0.2 Rpm 431 475 521 568 615 663 712 760 809 859 908 933 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 0.4 Bhp 1.99 2.69 3.53 4.52 5.68 7.01 8.53 10.24 12.15 14.27 16.61 17.87 Rpm 484 523 565 608 652 697 743 790 837 885 933 957 1.2 Rpm 667 692 721 753 788 824 862 902 943 985 1028 1049 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 1.4 Bhp 3.85 4.66 5.63 6.74 8.02 9.47 11.09 12.90 14.91 17.13 19.56 20.86 Rpm 707 730 757 787 819 854 891 929 968 1009 1051 1072 2.2 Rpm 854 870 889 912 938 967 998 1031 1066 1102 1140 1159 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 2.4 Bhp 5.93 6.81 7.85 9.05 10.43 11.98 13.72 15.64 17.76 20.08 22.61 23.95 Rpm 887 902 920 941 966 993 1023 1055 1089 1124 1161 1180 3.2 Rpm 1009 1022 1036 1053 1073 1096 1121 1149 1179 1211 1245 1262 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 3.4 Bhp 8.21 9.16 10.25 11.51 12.95 14.58 16.40 18.42 20.63 23.06 25.69 27.09 Rpm 1037 1050 1064 1080 1099 1121 1145 1172 1201 1232 1265 1282 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 2.35 534 2.72 580 3.08 569 3.47 612 3.94 606 4.36 646 4.96 646 5.40 683 6.14 687 6.60 722 7.49 730 7.98 762 9.03 774 9.54 804 10.76 819 11.29 847 12.69 864 13.24 891 14.83 910 15.40 936 17.19 957 17.77 981 18.45 981 19.04 1004 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Bhp Rpm Bhp Rpm 4.24 746 4.65 783 5.07 767 5.49 802 6.06 791 6.49 825 7.20 819 7.65 851 8.50 850 8.97 880 9.96 883 10.47 912 11.61 918 12.13 945 13.45 955 13.99 981 15.48 993 16.04 1018 17.71 1033 18.30 1056 20.16 1073 20.77 1096 21.47 1094 22.09 1116 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Bhp Rpm Bhp Rpm 6.37 919 6.82 950 7.26 933 7.73 964 8.31 950 8.79 979 9.53 970 10.02 998 10.92 993 11.42 1020 12.49 1020 13.01 1046 14.25 1049 14.78 1073 16.19 1079 16.75 1103 18.33 1112 18.90 1135 20.67 1147 21.26 1168 23.22 1182 23.84 1203 24.58 1201 25.21 1221 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Bhp Rpm Bhp Rpm 8.69 1064 9.17 1091 9.65 1077 10.14 1104 10.75 1090 11.26 1117 12.02 1106 12.54 1131 13.47 1124 14.00 1149 15.11 1145 15.65 1169 16.95 1168 17.50 1191 18.98 1195 19.55 1217 21.21 1223 21.80 1244 23.66 1253 24.26 1274 26.31 1285 26.93 — 27.71 — — — 0.8 1.0 Bhp 3.08 3.86 4.78 5.84 7.07 8.47 10.05 11.82 13.79 15.97 18.36 19.64 Rpm 625 653 684 719 755 794 834 875 917 960 1004 1027 Bhp 5.07 5.92 6.94 8.11 9.46 10.97 12.66 14.54 16.62 18.89 21.38 22.71 Rpm 819 836 857 882 909 939 972 1006 1042 1079 1118 1137 Bhp 7.28 8.20 9.27 10.51 11.93 13.53 15.32 17.30 19.48 21.86 24.45 25.83 Rpm 980 993 1008 1026 1047 1071 1098 1126 1157 1190 1224 1242 Bhp 9.65 10.64 11.77 13.06 14.53 16.19 18.06 20.12 22.38 24.86 — — Rpm 1116 1129 1142 1157 1173 1192 1214 1239 1265 1294 — — 1.8 Bhp 3.46 4.26 5.20 6.29 7.55 8.97 10.57 12.36 14.35 16.55 18.96 20.25 2.0 2.8 Bhp 5.49 6.36 7.39 8.58 9.94 11.48 13.19 15.09 17.18 19.48 21.99 23.33 3.0 3.8 Bhp 7.74 8.67 9.75 11.00 12.44 14.05 15.86 17.86 20.06 22.46 25.07 26.46 4.0 Bhp 10.14 11.15 12.29 13.59 15.07 16.74 18.62 20.69 22.97 25.46 — — Table 16 — Fan Performance — 50AJ,AK,A2,A3040 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 475 521 568 615 663 712 760 809 859 908 958 1007 1057 Bhp 2.69 3.53 4.52 5.68 7.01 8.53 10.24 12.15 14.27 16.61 19.18 21.98 25.02 0.4 Rpm 523 565 608 652 697 743 790 837 885 933 981 1030 1079 2.2 Rpm 870 889 912 938 967 998 1031 1066 1102 1140 1178 1218 — Bhp 6.81 7.85 9.05 10.43 11.98 13.72 15.64 17.76 20.08 22.61 25.36 28.34 — Bhp 3.08 3.94 4.96 6.14 7.49 9.03 10.76 12.69 14.83 17.19 19.77 22.59 25.65 2.4 Rpm 902 920 941 966 993 1023 1055 1089 1124 1161 1199 1238 — Bhp 7.26 8.31 9.53 10.92 12.49 14.25 16.19 18.33 20.67 23.22 25.99 28.99 — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 3.86 653 4.26 692 4.66 730 5.07 4.78 684 5.20 721 5.63 757 6.06 5.84 719 6.29 753 6.74 787 7.20 7.07 755 7.55 788 8.02 819 8.50 8.47 794 8.97 824 9.47 854 9.96 10.05 834 10.57 862 11.09 891 11.61 11.82 875 12.36 902 12.90 929 13.45 13.79 917 14.35 943 14.91 968 15.48 15.97 960 16.55 985 17.13 1009 17.71 18.36 1004 18.96 1028 19.56 1051 20.16 20.98 1049 21.60 1071 22.22 1093 22.84 23.84 1095 24.47 1116 25.10 1137 25.74 26.93 1140 27.58 1161 28.23 1181 28.89 Rpm 767 791 819 850 883 918 955 993 1033 1073 1115 1157 — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 964 8.20 993 8.67 1022 9.16 1050 9.65 979 9.27 1008 9.75 1036 10.25 1064 10.75 998 10.51 1026 11.00 1053 11.51 1080 12.02 1020 11.93 1047 12.44 1073 12.95 1099 13.47 1046 13.53 1071 14.05 1096 14.58 1121 15.11 1073 15.32 1098 15.86 1121 16.40 1145 16.95 1103 17.30 1126 17.86 1149 18.42 1172 18.98 1135 19.48 1157 20.06 1179 20.63 1201 21.21 1168 21.86 1190 22.46 1211 23.06 1232 23.66 1203 24.45 1224 25.07 1245 25.69 1265 26.31 1240 27.26 1260 27.90 1279 28.54 1299 29.18 — — — — — — — — — — — — — — — — Rpm 1077 1090 1106 1124 1145 1168 1195 1223 1253 1285 — — — 0.6 Rpm 569 606 646 687 730 774 819 864 910 957 1004 1052 1099 Bhp 3.47 4.36 5.40 6.60 7.98 9.54 11.29 13.24 15.40 17.77 20.37 23.21 26.29 2.6 Rpm 933 950 970 993 1020 1049 1079 1112 1147 1182 1219 — — Bhp 7.73 8.79 10.02 11.42 13.01 14.78 16.75 18.90 21.26 23.84 26.63 — — Rpm 612 646 683 722 762 804 847 891 936 981 1027 1073 1120 1.6 Bhp 5.49 6.49 7.65 8.97 10.47 12.13 13.99 16.04 18.30 20.77 23.46 26.39 — 1.8 Rpm 802 825 851 880 912 945 981 1018 1056 1096 1136 1178 — 3.6 Bhp 10.14 11.26 12.54 14.00 15.65 17.50 19.55 21.80 24.26 26.93 — — — Bhp 5.92 6.94 8.11 9.46 10.97 12.66 14.54 16.62 18.89 21.38 24.09 27.04 — 2.0 Rpm 836 857 882 909 939 972 1006 1042 1079 1118 1157 1198 — 3.8 Rpm 1104 1117 1131 1149 1169 1191 1217 1244 1274 — — — — Bhp 10.64 11.77 13.06 14.53 16.19 18.06 20.12 22.38 24.86 — — — — Bhp 6.36 7.39 8.58 9.94 11.48 13.19 15.09 17.18 19.48 21.99 24.72 27.68 — 4.0 Rpm 1129 1142 1157 1173 1192 1214 1239 1265 1294 — — — — Bhp 11.15 12.29 13.59 15.07 16.74 18.62 20.69 22.97 25.46 — — — — 2. Conversion — Bhp to watts: LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. Watts = Bhp x 746 Motor efficiency 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. 14 Table 17 — Fan Performance — 50AJ,AK041 Units AIRFLOW (Cfm) 0.2 Rpm 475 521 568 615 663 712 760 809 859 908 958 1007 1057 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 0.4 Bhp 2.69 3.53 4.52 5.68 7.01 8.53 10.24 12.15 14.27 16.61 19.18 21.98 25.02 Rpm 523 565 608 652 697 743 790 837 885 933 981 1030 1079 1.2 Rpm 692 721 753 788 824 862 902 943 985 1028 1071 1116 1161 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 1.4 Bhp 4.66 5.63 6.74 8.02 9.47 11.09 12.90 14.91 17.13 19.56 22.22 25.10 28.23 Rpm 730 757 787 819 854 891 929 968 1009 1051 1093 1137 1181 2.2 Rpm 870 889 912 938 967 998 1031 1066 1102 1140 1178 1218 — 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 2.4 Bhp 6.81 7.85 9.05 10.43 11.98 13.72 15.64 17.76 20.08 22.61 25.36 28.34 — Rpm 902 920 941 966 993 1023 1055 1089 1124 1161 1199 1238 — 3.2 Rpm 1022 1036 1053 1073 1096 1121 1149 1179 1211 1245 1279 — — 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 3.4 Bhp 9.16 10.25 11.51 12.95 14.58 16.40 18.42 20.63 23.06 25.69 28.54 — — Rpm 1050 1064 1080 1099 1121 1145 1172 1201 1232 1265 1299 — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 3.08 569 3.47 612 3.94 606 4.36 646 4.96 646 5.40 683 6.14 687 6.60 722 7.49 730 7.98 762 9.03 774 9.54 804 10.76 819 11.29 847 12.69 864 13.24 891 14.83 910 15.40 936 17.19 957 17.77 981 19.77 1004 20.37 1027 22.59 1052 23.21 1073 25.65 1099 26.29 1120 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Bhp Rpm Bhp Rpm 5.07 767 5.49 802 6.06 791 6.49 825 7.20 819 7.65 851 8.50 850 8.97 880 9.96 883 10.47 912 11.61 918 12.13 945 13.45 955 13.99 981 15.48 993 16.04 1018 17.71 1033 18.30 1056 20.16 1073 20.77 1096 22.84 1115 23.46 1136 25.74 1157 26.39 1178 28.89 — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Bhp Rpm Bhp Rpm 7.26 933 7.73 964 8.31 950 8.79 979 9.53 970 10.02 998 10.92 993 11.42 1020 12.49 1020 13.01 1046 14.25 1049 14.78 1073 16.19 1079 16.75 1103 18.33 1112 18.90 1135 20.67 1147 21.26 1168 23.22 1182 23.84 1203 25.99 1219 26.63 1240 28.99 — — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Bhp Rpm Bhp Rpm 9.65 1077 10.14 1104 10.75 1090 11.26 1117 12.02 1106 12.54 1131 13.47 1124 14.00 1149 15.11 1145 15.65 1169 16.95 1168 17.50 1191 18.98 1195 19.55 1217 21.21 1223 21.80 1244 23.66 1253 24.26 1274 26.31 1285 26.93 — 29.18 — — — — — — — — — — — 0.8 1.0 Bhp 3.86 4.78 5.84 7.07 8.47 10.05 11.82 13.79 15.97 18.36 20.98 23.84 26.93 Rpm 653 684 719 755 794 834 875 917 960 1004 1049 1095 1140 Bhp 5.92 6.94 8.11 9.46 10.97 12.66 14.54 16.62 18.89 21.38 24.09 27.04 — Rpm 836 857 882 909 939 972 1006 1042 1079 1118 1157 1198 — Bhp 8.20 9.27 10.51 11.93 13.53 15.32 17.30 19.48 21.86 24.45 27.26 — — Rpm 993 1008 1026 1047 1071 1098 1126 1157 1190 1224 1260 — — Bhp 10.64 11.77 13.06 14.53 16.19 18.06 20.12 22.38 24.86 — — — — Rpm 1129 1142 1157 1173 1192 1214 1239 1265 1294 — — — — 1.8 Bhp 4.26 5.20 6.29 7.55 8.97 10.57 12.36 14.35 16.55 18.96 21.60 24.47 27.58 2.0 2.8 Bhp 6.36 7.39 8.58 9.94 11.48 13.19 15.09 17.18 19.48 21.99 24.72 27.68 — 3.0 3.8 Bhp 8.67 9.75 11.00 12.44 14.05 15.86 17.86 20.06 22.46 25.07 27.90 — — 4.0 Bhp 11.15 12.29 13.59 15.07 16.74 18.62 20.69 22.97 25.46 — — — — Table 18 — Fan Performance — 50AJ,AK,A2,A3050 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 485 530 577 625 673 722 771 821 870 920 971 1021 1071 Bhp 2.76 3.62 4.62 5.80 7.15 8.69 10.43 12.37 14.52 16.89 19.50 22.35 25.43 0.4 Rpm 532 574 617 661 707 753 800 848 896 945 994 1043 1092 2.2 Rpm 876 896 919 945 975 1006 1040 1075 1112 1150 1190 1230 1271 Bhp 6.90 7.95 9.17 10.56 12.13 13.89 15.84 17.99 20.34 22.91 25.70 28.73 31.99 Bhp 3.15 4.03 5.06 6.26 7.63 9.19 10.95 12.91 15.08 17.48 20.10 22.96 26.07 0.6 Rpm 577 615 655 697 740 784 829 875 922 969 1017 1065 1113 2.4 Rpm 908 926 948 973 1001 1032 1064 1098 1134 1172 1210 1250 1290 Bhp 7.35 8.41 9.64 11.05 12.64 14.42 16.39 18.56 20.93 23.52 26.34 29.38 32.67 Bhp 3.54 4.45 5.50 6.73 8.12 9.70 11.48 13.46 15.65 18.06 20.71 23.59 26.71 2.6 Rpm 939 956 977 1001 1027 1057 1088 1121 1156 1193 1230 1269 — Bhp 7.82 8.89 10.13 11.55 13.16 14.96 16.94 19.13 21.53 24.14 26.97 30.04 — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 620 3.94 661 4.34 700 4.74 737 5.16 655 4.87 692 5.29 729 5.72 764 6.15 692 5.95 727 6.40 761 6.85 794 7.30 731 7.20 764 7.67 796 8.14 827 8.62 772 8.62 803 9.11 833 9.61 863 10.11 814 10.22 843 10.74 872 11.26 900 11.78 857 12.01 885 12.55 912 13.10 938 13.64 901 14.01 928 14.57 953 15.14 978 15.70 947 16.22 971 16.80 996 17.39 1020 17.97 993 18.65 1016 19.25 1039 19.86 1062 20.46 1039 21.32 1061 21.93 1083 22.55 1105 23.18 1086 24.21 1107 24.85 1128 25.49 1149 26.13 1133 27.36 1154 28.01 1174 28.66 1194 29.33 Rpm 774 798 827 858 891 927 964 1003 1043 1084 1126 1170 1213 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 970 8.29 999 8.77 1027 9.25 1055 9.74 986 9.37 1014 9.86 1042 10.36 1069 10.86 1005 10.62 1032 11.12 1059 11.63 1086 12.14 1027 12.06 1054 12.57 1080 13.09 1105 13.61 1053 13.68 1078 14.21 1103 14.74 1128 15.27 1081 15.49 1105 16.03 1129 16.58 1153 17.12 1112 17.50 1135 18.06 1158 18.62 1180 19.18 1144 19.71 1166 20.29 1188 20.86 1210 21.45 1178 22.12 1199 22.72 1221 23.32 1241 23.92 1214 24.76 1234 25.37 1255 25.99 1275 26.61 1250 27.61 1270 28.25 1290 28.89 — — 1289 30.70 — — — — — — — — — — — — — — Rpm 1082 1096 1112 1130 1152 1176 1203 1231 1262 1295 — — — 15 1.6 Bhp 5.58 6.59 7.76 9.10 10.61 12.31 14.19 16.27 18.56 21.07 23.80 26.78 29.99 1.8 Rpm 809 832 858 888 920 954 990 1028 1066 1107 1148 1190 1233 3.6 Bhp 10.24 11.37 12.66 14.14 15.81 17.68 19.75 22.03 24.52 27.23 — — — Bhp 6.01 7.03 8.22 9.58 11.12 12.83 14.74 16.84 19.15 21.68 24.44 27.42 30.65 2.0 Rpm 843 864 889 917 947 980 1015 1052 1089 1129 1169 1210 1252 3.8 Rpm 1109 1122 1137 1155 1176 1199 1225 1253 1283 — — — — Bhp 10.74 11.88 13.18 14.67 16.35 18.23 20.32 22.62 25.13 — — — — Bhp 6.45 7.49 8.69 10.07 11.62 13.36 15.29 17.41 19.75 22.30 25.07 28.08 31.33 4.0 Rpm 1134 1148 1162 1179 1199 1221 1246 1274 — — — — — Bhp 11.25 12.40 13.71 15.21 16.90 18.80 20.90 23.21 — — — — — Table 19 — Fan Performance — 50AJ,AK051 Units AIRFLOW (Cfm) 0.2 Rpm 397 450 477 505 533 561 590 619 648 678 707 737 767 797 827 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 0.4 Bhp 2.69 4.03 4.83 5.74 6.75 7.88 9.12 10.48 11.96 13.57 15.30 17.18 19.20 21.35 23.66 Rpm 461 509 533 558 584 610 637 664 692 719 748 776 804 833 862 Bhp 6.06 7.62 8.55 9.59 10.73 11.98 13.35 14.84 16.45 18.19 20.05 22.06 24.19 26.47 28.89 Rpm 686 723 742 762 782 803 825 847 870 893 917 940 965 989 1014 1.2 Rpm 649 686 706 727 748 770 792 815 838 862 886 911 935 961 986 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) Bhp 10.06 11.75 12.75 13.85 15.07 16.41 17.86 19.45 21.15 22.99 24.97 27.08 29.32 31.71 34.25 Rpm 847 880 897 915 933 952 971 991 1011 1032 1053 1075 1097 1119 1142 Bhp 14.50 16.32 17.38 18.54 19.81 21.21 22.73 24.37 26.15 28.06 30.11 32.30 34.64 — — Rpm 979 1010 1026 1042 1059 1077 1095 1113 1132 1151 1171 1191 — — — 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 0.8 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Bhp Rpm Bhp Rpm 10.92 875 11.80 902 12.63 907 13.53 934 13.64 924 14.55 951 14.76 942 15.68 968 15.99 960 16.92 986 17.34 978 18.28 1004 18.81 997 19.77 1023 20.41 1017 21.38 1042 22.13 1037 23.12 1061 23.98 1057 24.99 1081 25.97 1078 26.99 1102 28.10 1099 29.14 1123 30.37 1121 31.42 1144 32.78 1143 33.85 1166 35.33 1165 36.42 1188 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Rpm Bhp Rpm 1003 16.36 1027 1033 18.24 1057 1049 19.32 1072 1066 20.51 1088 1082 21.81 1105 1100 23.22 1122 1117 24.76 1140 1136 26.43 1158 1154 28.24 1176 1173 30.17 1195 1193 32.25 — — — — — — — — — — — — — 3.4 1.0 Bhp 4.63 6.12 7.01 8.01 9.11 10.32 11.64 13.07 14.64 16.32 18.14 20.09 22.17 24.40 26.78 Rpm 608 647 668 689 711 734 757 781 805 829 854 879 905 931 957 Bhp 8.40 10.04 11.01 12.09 13.28 14.59 16.02 17.57 19.24 21.04 22.98 25.05 27.25 29.60 32.09 Rpm 787 821 839 857 876 896 916 937 958 979 1001 1024 1046 1070 1093 Bhp 12.68 14.45 15.48 16.62 17.87 19.25 20.74 22.36 24.11 26.00 28.02 30.18 32.48 34.93 37.52 Rpm 929 960 976 993 1011 1029 1047 1066 1085 1105 1126 1146 1167 1189 — Bhp 17.30 19.22 20.32 21.52 22.82 24.25 25.80 27.48 29.29 31.24 — — — — — Rpm 1050 1079 1095 1111 1127 1144 1161 1179 1197 — — — — — — 1.8 Bhp 6.82 8.40 9.35 10.40 11.56 12.84 14.23 15.74 17.37 19.13 21.02 23.05 25.21 27.51 29.95 2.4 3.2 Rpm 954 985 1001 1018 1035 1053 1071 1090 1109 1128 1148 1169 1190 — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Rpm Bhp Rpm 722 7.60 755 757 9.21 790 776 10.17 808 795 11.24 827 815 12.41 846 836 13.71 866 857 15.12 887 878 16.65 908 900 18.30 930 923 20.08 952 946 22.00 974 969 24.04 997 993 26.23 1020 1017 28.55 1044 1041 31.02 1068 1.4 2.2 Rpm 818 851 868 886 905 924 944 964 985 1006 1028 1050 1072 1095 1118 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 3.31 516 3.96 564 4.71 560 5.41 605 5.55 582 6.27 627 6.49 606 7.24 649 7.53 630 8.32 672 8.68 655 9.50 696 9.95 680 10.79 720 11.33 706 12.20 744 12.84 732 13.74 769 14.47 758 15.40 795 16.24 785 17.19 821 18.14 812 19.11 847 20.18 840 21.17 873 22.36 867 23.38 900 24.68 895 25.72 927 2.0 2.8 Bhp 9.23 10.89 11.87 12.96 14.17 15.49 16.94 18.50 20.19 22.01 23.97 26.06 28.28 30.65 33.17 3.0 3.8 Bhp 15.42 17.28 18.35 19.52 20.81 22.21 23.74 25.40 27.19 29.11 31.17 33.38 — — — Bhp 5.33 6.86 7.77 8.79 9.91 11.14 12.49 13.96 15.54 17.25 19.09 21.07 23.18 25.43 27.83 Bhp 13.59 15.38 16.42 17.57 18.83 20.22 21.73 23.36 25.13 27.03 29.06 31.24 33.55 36.02 — 4.0 Bhp 18.26 20.22 21.32 22.53 23.85 25.29 26.85 28.54 30.36 — — — — — — Table 20 — Fan Performance — 50AJ,AK,A2,A3060 Units AIRFLOW (Cfm) 12,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 26,000 27,000 AIRFLOW (Cfm) 12,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 26,000 27,000 0.2 Rpm 450 505 533 561 590 619 648 678 707 737 767 797 827 857 888 0.4 Bhp 4.02 5.74 6.75 7.88 9.12 10.48 11.96 13.57 15.30 17.18 19.20 21.35 23.66 26.11 28.72 Rpm 509 558 584 610 637 664 692 719 748 776 804 833 862 891 920 Bhp 11.75 13.85 15.07 16.41 17.86 19.45 21.15 22.99 24.97 27.08 29.32 31.71 34.25 36.93 39.76 Rpm 880 915 933 952 971 991 1011 1032 1053 1075 1097 1119 1142 1165 1188 2.2 Rpm 851 886 905 924 944 964 985 1006 1028 1050 1072 1095 1118 1141 1165 0.6 Bhp 4.71 6.49 7.53 8.68 9.95 11.33 12.84 14.47 16.24 18.14 20.18 22.36 24.68 27.16 29.79 Rpm 560 606 630 655 680 706 732 758 785 812 840 867 895 923 952 Bhp 12.63 14.76 15.99 17.34 18.81 20.41 22.13 23.98 25.97 28.10 30.37 32.78 35.33 38.04 40.89 Rpm 907 942 960 978 997 1017 1037 1057 1078 1099 1121 1143 1165 1188 — 2.4 0.8 Bhp 5.41 7.24 8.32 9.50 10.79 12.20 13.74 15.40 17.19 19.11 21.17 23.38 25.72 28.23 30.88 Rpm 605 649 672 696 720 744 769 795 821 847 873 900 927 954 982 Bhp 13.53 15.68 16.92 18.28 19.77 21.38 23.12 24.99 26.99 29.14 31.42 33.85 36.42 39.15 — Rpm 934 968 986 1004 1023 1042 1061 1081 1102 1123 1144 1166 1188 — — 2.6 2.8 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.0 1.2 1.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 6.12 647 6.86 686 7.62 723 8.40 8.01 689 8.79 727 9.59 762 10.40 9.11 711 9.91 748 10.73 782 11.56 10.32 734 11.14 770 11.98 803 12.84 11.64 757 12.49 792 13.35 825 14.23 13.07 781 13.96 815 14.84 847 15.74 14.64 805 15.54 838 16.45 870 17.37 16.32 829 17.25 862 18.19 893 19.13 18.14 854 19.09 886 20.05 917 21.02 20.09 879 21.07 911 22.06 940 23.05 22.17 905 23.18 935 24.19 965 25.21 24.40 931 25.43 961 26.47 989 27.51 26.78 957 27.83 986 28.89 1014 29.95 29.30 984 30.38 1012 31.46 1040 32.55 31.97 1011 33.08 1038 34.19 1065 35.29 Rpm 757 795 815 836 857 878 900 923 946 969 993 1017 1041 1066 1091 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.0 3.2 3.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 14.45 960 15.38 985 16.32 1010 17.28 16.62 993 17.57 1018 18.54 1042 19.52 17.87 1011 18.83 1035 19.81 1059 20.81 19.25 1029 20.22 1053 21.21 1077 22.21 20.74 1047 21.73 1071 22.73 1095 23.74 22.36 1066 23.36 1090 24.37 1113 25.40 24.11 1085 25.13 1109 26.15 1132 27.19 26.00 1105 27.03 1128 28.06 1151 29.11 28.02 1126 29.06 1148 30.11 1171 31.17 30.18 1146 31.24 1169 32.30 1191 33.38 32.48 1167 33.55 1190 34.64 — — 34.93 1189 36.02 — — — — 37.52 — — — — — — — — — — — — — — — — — — — — Rpm 1033 1066 1082 1100 1117 1136 1154 1173 1193 — — — — — — 16 1.6 1.8 Bhp 9.21 11.24 12.41 13.71 15.12 16.65 18.30 20.08 22.00 24.04 26.23 28.55 31.02 33.64 36.40 Rpm 790 827 846 866 887 908 930 952 974 997 1020 1044 1068 1092 1117 Bhp 18.24 20.51 21.81 23.22 24.76 26.43 28.24 30.17 32.25 — — — — — — Rpm 1057 1088 1105 1122 1140 1158 1176 1195 — — — — — — — 3.6 2.0 Bhp 10.04 12.09 13.28 14.59 16.02 17.57 19.24 21.04 22.98 25.05 27.25 29.60 32.09 34.73 37.52 Rpm 821 857 876 896 916 937 958 979 1001 1024 1046 1070 1093 1117 1141 Bhp 19.22 21.52 22.82 24.25 25.80 27.48 29.29 31.24 — — — — — — — Rpm 1079 1111 1127 1144 1161 1179 1197 — — — — — — — — 3.8 Bhp 10.89 12.96 14.17 15.49 16.94 18.50 20.19 22.01 23.97 26.06 28.28 30.65 33.17 35.83 38.64 4.0 Bhp 20.22 22.53 23.85 25.29 26.85 28.54 30.36 — — — — — — — — Table 21 — Fan Performance — 48AW,AY020,025 and 48A4,A5020 Units AIRFLOW (CFM) 4,000 5,000 6,000 7,000 7,500 8,000 9,000 10,000 11,000 12,000 12,500 13,000 AIRFLOW (CFM) 4,000 5,000 6,000 7,000 7,500 8,000 9,000 10,000 11,000 12,000 12,500 13,000 0.2 Rpm Bhp 339 0.71 384 1.10 433 1.61 484 2.27 511 2.66 538 3.09 593 4.07 649 5.23 706 6.58 763 8.12 792 8.97 821 9.87 0.4 Rpm Bhp 414 0.97 452 1.37 494 1.89 540 2.56 563 2.95 588 3.38 639 4.37 691 5.54 744 6.89 799 8.45 827 9.30 855 10.20 0.6 Rpm Bhp 478 1.25 510 1.66 548 2.19 590 2.87 612 3.26 634 3.70 682 4.69 731 5.87 782 7.23 834 8.79 860 9.64 887 10.55 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 534 1.54 585 1.84 631 2.14 674 2.44 563 1.96 611 2.28 656 2.60 698 2.93 597 2.51 643 2.84 686 3.18 726 3.52 636 3.19 679 3.53 719 3.88 757 4.24 656 3.59 698 3.94 737 4.29 775 4.66 678 4.03 718 4.38 756 4.74 793 5.11 722 5.03 760 5.39 796 5.76 831 6.13 769 6.21 805 6.58 839 6.95 872 7.34 817 7.58 851 7.95 884 8.33 915 8.72 867 9.14 899 9.52 930 9.90 960 10.30 893 10.00 924 10.38 954 10.77 983 11.16 918 10.91 949 11.29 978 11.68 1007 12.08 1.6 Rpm Bhp 714 2.75 738 3.27 764 3.88 794 4.61 810 5.03 827 5.49 864 6.52 904 7.73 945 9.12 989 10.71 1012 11.57 1034 12.49 1.8 Rpm Bhp 751 3.06 775 3.60 800 4.23 829 4.98 845 5.41 861 5.87 896 6.91 934 8.13 975 9.53 1017 11.12 1039 11.99 1062 12.92 2.0 Rpm Bhp 787 3.37 811 3.94 835 4.60 863 5.36 877 5.79 893 6.26 927 7.32 964 8.54 1003 9.95 1045 11.54 1066 12.42 1088 13.35 2.2 Rpm Bhp 820 3.68 844 4.28 869 4.96 895 5.74 909 6.18 925 6.66 957 7.72 993 8.96 1031 10.37 1071 11.97 1092 12.85 1113 13.78 2.4 Rpm Bhp 852 3.99 877 4.63 901 5.33 926 6.13 940 6.57 955 7.06 986 8.13 1021 9.38 1058 10.80 1097 12.41 1118 13.29 1139 14.22 2.6 Rpm Bhp 883 4.30 907 4.97 931 5.70 956 6.52 970 6.97 984 7.46 1015 8.55 1048 9.80 1084 11.23 1123 12.85 1143 13.74 1163 14.67 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 912 4.62 940 4.93 967 5.25 993 5.57 937 5.31 966 5.66 993 6.01 1020 6.35 961 6.07 990 6.44 1017 6.81 1044 7.19 986 6.91 1014 7.30 1042 7.70 1068 8.10 999 7.37 1027 7.78 1054 8.18 1081 8.59 1013 7.87 1040 8.28 1067 8.69 1094 9.11 1042 8.97 1069 9.39 1096 9.82 1121 10.25 1075 10.23 1101 10.67 1126 11.11 1151 11.55 1110 11.67 1135 12.12 1160 12.56 1184 13.02 1148 13.30 1172 13.75 1196 14.21 — — 1167 14.19 1191 14.64 — — — — — — — — — — — — 3.6 Rpm Bhp 1019 5.89 1046 6.70 1070 7.57 1094 8.50 1107 9.00 1119 9.53 1146 10.69 1176 12.00 — — — — — — — — 3.8 Rpm Bhp 1043 6.21 1071 7.05 1096 7.94 1120 8.90 1132 9.41 1144 9.95 1171 11.12 1200 12.45 — — — — — — — — 4.0 Rpm Bhp 1067 6.53 1095 7.40 1121 8.32 1145 9.30 1157 9.82 1169 10.37 1195 11.56 — — — — — — — — — — Table 22 — Fan Performance — 48AW,AY027,030 and 48A4,A5025-030 Units AIRFLOW (CFM) 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 AIRFLOW (CFM) 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 0.2 Rpm Bhp 342 0.72 389 1.11 439 1.64 492 2.31 546 3.14 602 4.13 659 5.31 717 6.67 775 8.23 834 9.99 893 11.97 953 14.17 0.4 Rpm Bhp 417 0.98 456 1.38 499 1.92 546 2.60 596 3.43 647 4.43 701 5.62 755 6.99 811 8.56 867 10.33 924 12.32 982 14.53 0.6 Rpm Bhp 480 1.26 514 1.68 553 2.22 596 2.91 642 3.75 690 4.76 740 5.95 792 7.33 845 8.90 899 10.68 954 12.68 1010 14.90 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 536 1.55 587 1.85 633 2.15 676 2.45 566 1.98 614 2.30 659 2.62 701 2.95 602 2.54 647 2.87 689 3.21 730 3.56 641 3.24 684 3.58 724 3.93 762 4.29 684 4.09 724 4.44 762 4.80 798 5.17 730 5.10 768 5.46 803 5.83 838 6.21 777 6.30 813 6.67 847 7.04 880 7.43 827 7.68 860 8.06 893 8.44 924 8.83 878 9.27 909 9.64 940 10.03 970 10.43 930 11.05 960 11.44 989 11.83 1017 12.24 983 13.06 1012 13.44 1039 13.85 1066 14.26 1037 15.28 1064 15.68 1091 16.08 1116 16.50 1.6 Rpm Bhp 715 2.76 740 3.29 768 3.91 798 4.66 833 5.55 871 6.60 911 7.83 954 9.24 999 10.84 1045 12.65 1093 14.68 1142 16.93 1.8 Rpm Bhp 753 3.07 777 3.62 804 4.27 833 5.03 866 5.93 903 7.00 942 8.23 983 9.65 1026 11.26 1072 13.08 1118 15.11 1166 17.36 2.0 Rpm Bhp 788 3.38 813 3.96 838 4.63 867 5.41 898 6.32 933 7.40 971 8.64 1011 10.07 1054 11.69 1098 13.51 1143 15.54 1190 17.80 2.2 Rpm Bhp 821 3.69 846 4.31 872 5.00 899 5.79 930 6.72 963 7.80 1000 9.06 1039 10.49 1080 12.12 1123 13.95 1168 15.99 — — 2.4 Rpm Bhp 853 4.00 879 4.65 903 5.36 930 6.18 960 7.12 992 8.22 1028 9.48 1066 10.92 1106 12.56 1148 14.39 1192 16.44 — — 2.6 Rpm Bhp 884 4.31 909 4.99 934 5.73 960 6.57 989 7.53 1020 8.63 1055 9.91 1092 11.36 1131 13.00 1172 14.84 — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 913 4.63 941 4.95 968 5.26 994 5.58 939 5.34 968 5.68 995 6.03 1022 6.38 964 6.10 992 6.48 1020 6.85 1047 7.22 989 6.96 1018 7.36 1045 7.75 1072 8.15 1017 7.94 1045 8.35 1072 8.76 1098 9.18 1048 9.06 1075 9.48 1101 9.91 1126 10.34 1081 10.34 1107 10.77 1133 11.22 1157 11.66 1117 11.80 1142 12.24 1167 12.69 1191 13.15 1156 13.45 1180 13.90 — — — — 1196 15.30 — — — — — — — — — — — — — — — — — — — — — — 3.6 Rpm Bhp 1020 5.90 1048 6.73 1073 7.60 1098 8.55 1124 9.60 1151 10.78 1182 12.11 — — — — — — — — — — 3.8 Rpm Bhp 1044 6.22 1073 7.08 1098 7.98 1123 8.95 1148 10.02 1176 11.21 — — — — — — — — — — — — 4.0 Rpm Bhp 1068 6.55 1097 7.43 1123 8.36 1148 9.35 1173 10.44 1200 11.65 — — — — — — — — — — — — LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb 2. Conversion — Bhp to watts: Watts = NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. Bhp x 746 Motor efficiency 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. 17 Table 23 — Fan Performance — 48AW,AY,A4,A5035 Units AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 10,500 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 10,500 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 0.2 Rpm 553 612 672 733 763 794 855 917 980 1042 1105 1168 1200 Bhp 2.59 3.45 4.47 5.67 6.33 7.04 8.60 10.36 12.32 14.49 16.88 19.49 20.88 0.4 Rpm 602 656 712 769 798 828 887 947 1008 1069 1130 1191 1222 2.2 Rpm 937 974 1012 1052 1073 1094 1138 1184 1232 1282 — — — Bhp 5.94 7.08 8.33 9.74 10.50 11.30 13.05 14.99 17.13 19.48 — — — Bhp 2.92 3.81 4.86 6.08 6.75 7.47 9.06 10.84 12.82 15.01 17.42 20.06 21.46 0.6 Rpm 648 698 750 805 832 861 918 976 1035 1094 1154 1214 1245 2.4 Rpm 967 1003 1041 1080 1100 1120 1163 1208 1255 — — — — Bhp 6.26 7.43 8.72 10.15 10.92 11.73 13.50 15.45 17.61 — — — — Bhp 3.26 4.17 5.24 6.48 7.17 7.90 9.51 11.31 13.31 15.52 17.96 20.61 22.03 2.6 Rpm 995 1031 1068 1106 1126 1146 1188 1232 1278 — — — — Bhp 6.57 7.77 9.10 10.55 11.34 12.16 13.95 15.92 18.09 — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 691 3.61 732 3.95 770 4.29 807 4.63 738 4.53 776 4.90 812 5.27 847 5.63 787 5.62 823 6.01 857 6.39 890 6.78 839 6.88 872 7.28 904 7.69 935 8.10 865 7.58 897 7.99 929 8.40 959 8.82 892 8.32 923 8.74 954 9.16 983 9.59 948 9.95 977 10.39 1005 10.83 1033 11.27 1004 11.77 1031 12.23 1058 12.69 1084 13.14 1061 13.79 1087 14.27 1112 14.75 1137 15.22 1119 16.03 1143 16.53 1167 17.02 1191 17.51 1178 18.48 1201 19.00 1224 19.51 1246 20.02 1237 21.16 1259 21.69 1281 22.23 — — 1267 22.58 1288 23.13 — — — — Rpm 842 881 922 966 989 1012 1060 1110 1161 1214 1268 — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 1022 6.87 1048 7.18 1073 7.48 1098 7.78 1058 8.12 1084 8.46 1109 8.79 1134 9.13 1094 9.47 1120 9.85 1145 10.22 1169 10.58 1132 10.96 1157 11.36 1182 11.76 1206 12.16 1151 11.75 1176 12.17 1201 12.59 1224 13.00 1171 12.59 1196 13.02 1220 13.45 1243 13.87 1212 14.40 1236 14.84 1259 15.30 1282 15.74 1255 16.39 1278 16.85 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Rpm 1122 1158 1193 1229 1248 1266 — — — — — — — 1.6 Bhp 4.96 6.00 7.17 8.51 9.24 10.01 11.71 13.60 15.70 18.01 20.53 — — 1.8 Rpm 875 913 953 995 1017 1040 1087 1135 1185 1237 1290 — — 3.6 Bhp 8.07 9.46 10.95 12.55 13.41 14.30 — — — — — — — Bhp 5.29 6.36 7.56 8.92 9.66 10.44 12.16 14.06 16.17 18.50 21.04 — — 2.0 Rpm 907 944 983 1024 1046 1067 1113 1160 1209 1260 — — — 3.8 Rpm 1145 1181 1216 1252 1271 1289 — — — — — — — Bhp 8.36 9.78 11.31 12.95 13.82 14.72 — — — — — — — Bhp 5.62 6.72 7.95 9.33 10.08 10.87 12.60 14.52 16.65 18.99 — — — 4.0 Rpm 1168 1204 1239 1275 1293 — — — — — — — — Bhp 8.66 10.11 11.66 13.34 14.22 — — — — — — — — Table 24 — Fan Performance — 48AW,AY036 Units AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 0.2 Rpm 475 526 579 633 687 742 797 852 908 964 1021 1049 0.4 Bhp 2.29 3.10 4.08 5.24 6.59 8.15 9.92 11.92 14.15 16.63 19.37 20.84 Rpm 527 573 621 671 723 775 827 881 935 989 1044 1072 1.2 Rpm 709 740 775 813 854 898 943 990 1038 1086 1136 1161 1.4 Bhp 4.25 5.18 6.28 7.57 9.04 10.72 12.61 14.72 17.06 19.65 22.49 24.01 Rpm 749 778 810 846 885 927 970 1016 1062 1110 1158 1183 2.2 Rpm 894 917 942 971 1003 1038 1075 1115 1157 1200 1245 1267 2.4 Bhp 6.46 7.48 8.66 10.03 11.60 13.38 15.37 17.59 20.04 22.73 25.67 27.24 Rpm 927 949 973 1001 1031 1065 1101 1139 1180 1222 1266 1288 3.2 Rpm 1046 1067 1089 1113 1139 1167 1199 1232 1269 — — — 3.4 Bhp 8.81 9.93 11.21 12.66 14.31 16.16 18.23 20.53 23.07 — — — Rpm 1073 1094 1116 1139 1164 1192 1222 1255 1290 — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 2.66 576 3.05 622 3.50 617 3.91 660 4.51 662 4.95 701 5.70 709 6.16 744 7.07 757 7.56 790 8.65 807 9.17 838 10.45 857 10.98 887 12.47 909 13.03 936 14.72 961 15.31 987 17.23 1014 17.83 1039 19.98 1068 20.60 1091 21.46 1095 22.09 1117 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Bhp Rpm Bhp Rpm 4.68 788 5.11 825 5.62 814 6.07 850 6.74 845 7.21 878 8.05 879 8.53 910 9.54 916 10.05 945 11.24 955 11.77 983 13.15 997 13.70 1024 15.29 1041 15.86 1066 17.65 1086 18.25 1110 20.26 1133 20.88 1156 23.12 1180 23.76 1202 24.65 1205 25.30 1226 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Bhp Rpm Bhp Rpm 6.92 958 7.38 988 7.96 980 8.44 1010 9.16 1003 9.66 1033 10.55 1030 11.06 1058 12.13 1059 12.67 1086 13.92 1091 14.47 1117 15.93 1126 16.50 1150 18.17 1163 18.75 1186 20.64 1202 21.24 1225 23.35 1243 23.97 1265 26.32 1286 26.96 — 27.89 — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Bhp Rpm Bhp Rpm 9.29 1099 9.78 1125 10.44 1121 10.95 1147 11.73 1142 12.26 1168 13.20 1165 13.75 1190 14.86 1189 15.43 1214 16.73 1216 17.31 1240 18.82 1246 19.41 1269 21.14 1277 21.74 1300 23.69 — — — — — — — — — — — — — — — See legend on page 17. 18 0.8 1.0 Bhp 3.44 4.33 5.39 6.62 8.05 9.68 11.52 13.59 15.89 18.43 21.23 22.73 Rpm 666 700 738 779 823 868 915 963 1013 1063 1114 1139 Bhp 5.55 6.53 7.69 9.03 10.56 12.30 14.25 16.43 18.84 21.49 24.39 25.94 Rpm 860 884 911 941 974 1011 1050 1091 1134 1178 1223 1247 Bhp 7.85 8.93 10.17 11.59 13.21 15.03 17.07 19.34 21.85 24.60 — — Rpm 1017 1039 1061 1086 1112 1142 1175 1210 1247 1286 — — Bhp 10.27 11.46 12.80 14.30 15.99 17.89 20.00 22.35 — — — — Rpm 1150 1172 1193 1215 1238 1264 1291 — — — — — 1.8 Bhp 3.84 4.75 5.83 7.09 8.54 10.20 12.07 14.15 16.48 19.04 21.86 23.36 2.0 2.8 Bhp 6.00 7.00 8.17 9.53 11.08 12.84 14.81 17.01 19.44 22.11 25.03 26.59 3.0 3.8 Bhp 8.33 9.43 10.69 12.12 13.75 15.59 17.65 19.94 22.46 25.23 — — 4.0 Bhp 10.76 11.98 13.33 14.86 16.56 18.48 20.61 — — — — — Table 25 — Fan Performance — 48AW,AY,A4,A5040 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 526 579 633 687 742 797 852 908 964 1021 1077 1133 1190 Bhp 3.10 4.08 5.24 6.59 8.15 9.92 11.92 14.15 16.63 19.37 22.37 25.65 29.21 0.4 Rpm 573 621 671 723 775 827 881 935 989 1044 1099 1155 — 2.2 Rpm 917 942 971 1003 1038 1075 1115 1157 1200 1245 1290 — — Bhp 7.48 8.66 10.03 11.60 13.38 15.37 17.59 20.04 22.73 25.67 28.88 — — Bhp 3.50 4.51 5.70 7.07 8.65 10.45 12.47 14.72 17.23 19.98 23.01 26.30 — 0.6 Rpm 617 662 709 757 807 857 909 961 1014 1068 1122 1176 — 2.4 Rpm 949 973 1001 1031 1065 1101 1139 1180 1222 1266 — — — Bhp 7.96 9.16 10.55 12.13 13.92 15.93 18.17 20.64 23.35 26.32 — — — Bhp 3.91 4.95 6.16 7.56 9.17 10.98 13.03 15.31 17.83 20.60 23.64 26.96 — 2.6 Rpm 980 1003 1030 1059 1091 1126 1163 1202 1243 1286 — — — Bhp 8.44 9.66 11.06 12.67 14.47 16.50 18.75 21.24 23.97 26.96 — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 660 4.33 700 4.75 740 5.18 778 5.62 701 5.39 738 5.83 775 6.28 810 6.74 744 6.62 779 7.09 813 7.57 846 8.05 790 8.05 823 8.54 854 9.04 885 9.54 838 9.68 868 10.20 898 10.72 927 11.24 887 11.52 915 12.07 943 12.61 970 13.15 936 13.59 963 14.15 990 14.72 1016 15.29 987 15.89 1013 16.48 1038 17.06 1062 17.65 1039 18.43 1063 19.04 1086 19.65 1110 20.26 1091 21.23 1114 21.86 1136 22.49 1158 23.12 1144 24.29 1165 24.94 1187 25.59 1208 26.25 1197 27.62 1217 28.29 1238 28.96 — — — — — — — — — — Rpm 814 845 879 916 955 997 1041 1086 1133 1180 1229 — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 1010 8.94 1039 9.43 1067 9.93 1094 10.44 1033 10.17 1061 10.69 1089 11.21 1116 11.73 1058 11.59 1086 12.12 1113 12.66 1139 13.20 1086 13.21 1112 13.75 1139 14.31 1164 14.86 1117 15.03 1142 15.59 1167 16.16 1192 16.73 1150 17.07 1175 17.65 1199 18.23 1222 18.82 1186 19.34 1210 19.94 1232 20.53 1255 21.14 1225 21.85 1247 22.46 1269 23.07 1290 23.69 1265 24.60 1286 25.23 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Rpm 1121 1142 1165 1189 1216 1246 1277 — — — — — — 1.6 Bhp 6.07 7.21 8.53 10.05 11.77 13.70 15.86 18.25 20.88 23.76 26.90 — — 1.8 Rpm 850 878 910 945 983 1024 1066 1110 1156 1202 1250 — — 3.6 Bhp 10.95 12.26 13.75 15.43 17.31 19.41 21.74 — — — — — — Bhp 6.53 7.69 9.03 10.56 12.30 14.25 16.43 18.84 21.49 24.39 27.56 — — 2.0 Rpm 884 911 941 974 1011 1050 1091 1134 1178 1223 1270 — — 3.8 Rpm 1147 1168 1190 1214 1240 1269 1300 — — — — — — Bhp 11.46 12.80 14.30 15.99 17.89 20.00 22.35 — — — — — — Bhp 7.00 8.17 9.53 11.08 12.84 14.81 17.01 19.44 22.11 25.03 28.22 — — 4.0 Rpm 1172 1193 1215 1238 1264 1291 — — — — — — — Bhp 11.98 13.33 14.86 16.56 18.48 20.61 — — — — — — — Table 26 — Fan Performance — 48AW,AY041 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 526 579 633 687 742 797 852 908 964 1021 1077 1133 1190 0.4 Bhp 3.10 4.08 5.24 6.59 8.15 9.92 11.92 14.15 16.63 19.37 22.37 25.65 29.21 Rpm 573 621 671 723 775 827 881 935 989 1044 1099 1155 — 1.2 Rpm 740 775 813 854 898 943 990 1038 1086 1136 1187 1238 — 1.4 Bhp 5.18 6.28 7.57 9.04 10.72 12.61 14.72 17.06 19.65 22.49 25.59 28.96 — Rpm 778 810 846 885 927 970 1016 1062 1110 1158 1208 — — 2.2 Rpm 917 942 971 1003 1038 1075 1115 1157 1200 1245 1290 — — 2.4 Bhp 7.48 8.66 10.03 11.60 13.38 15.37 17.59 20.04 22.73 25.67 28.88 — — Rpm 949 973 1001 1031 1065 1101 1139 1180 1222 1266 — — — 3.2 Rpm 1067 1089 1113 1139 1167 1199 1232 1269 — — — — — 3.4 Bhp 9.93 11.21 12.66 14.31 16.16 18.23 20.53 23.07 — — — — — Rpm 1094 1116 1139 1164 1192 1222 1255 1290 — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 3.50 617 3.91 660 4.51 662 4.95 701 5.70 709 6.16 744 7.07 757 7.56 790 8.65 807 9.17 838 10.45 857 10.98 887 12.47 909 13.03 936 14.72 961 15.31 987 17.23 1014 17.83 1039 19.98 1068 20.60 1091 23.01 1122 23.64 1144 26.30 1176 26.96 1197 — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Bhp Rpm Bhp Rpm 5.62 814 6.07 850 6.74 845 7.21 878 8.05 879 8.53 910 9.54 916 10.05 945 11.24 955 11.77 983 13.15 997 13.70 1024 15.29 1041 15.86 1066 17.65 1086 18.25 1110 20.26 1133 20.88 1156 23.12 1180 23.76 1202 26.25 1229 26.90 1250 — — — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Bhp Rpm Bhp Rpm 7.96 980 8.44 1010 9.16 1003 9.66 1033 10.55 1030 11.06 1058 12.13 1059 12.67 1086 13.92 1091 14.47 1117 15.93 1126 16.50 1150 18.17 1163 18.75 1186 20.64 1202 21.24 1225 23.35 1243 23.97 1265 26.32 1286 26.96 — — — — — — — — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Bhp Rpm Bhp Rpm 10.44 1121 10.95 1147 11.73 1142 12.26 1168 13.20 1165 13.75 1190 14.86 1189 15.43 1214 16.73 1216 17.31 1240 18.82 1246 19.41 1269 21.14 1277 21.74 1300 23.69 — — — — — — — — — — — — — — — — — — — — — — — See legend on page 17. 19 0.8 1.0 Bhp 4.33 5.39 6.62 8.05 9.68 11.52 13.59 15.89 18.43 21.23 24.29 27.62 — Rpm 700 738 779 823 868 915 963 1013 1063 1114 1165 1217 — Bhp 6.53 7.69 9.03 10.56 12.30 14.25 16.43 18.84 21.49 24.39 27.56 — — Rpm 884 911 941 974 1011 1050 1091 1134 1178 1223 1270 — — Bhp 8.94 10.17 11.59 13.21 15.03 17.07 19.34 21.85 24.60 — — — — Rpm 1039 1061 1086 1112 1142 1175 1210 1247 1286 — — — — Bhp 11.46 12.80 14.30 15.99 17.89 20.00 22.35 — — — — — — Rpm 1172 1193 1215 1238 1264 1291 — — — — — — — 1.8 Bhp 4.75 5.83 7.09 8.54 10.20 12.07 14.15 16.48 19.04 21.86 24.94 28.29 — 2.0 2.8 Bhp 7.00 8.17 9.53 11.08 12.84 14.81 17.01 19.44 22.11 25.03 28.22 — — 3.0 3.8 Bhp 9.43 10.69 12.12 13.75 15.59 17.65 19.94 22.46 25.23 — — — — 4.0 Bhp 11.98 13.33 14.86 16.56 18.48 20.61 — — — — — — — Table 27 — Fan Performance — 48AW,AY,A4,A5050 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 536 588 642 696 751 807 863 919 975 1032 1089 1146 1203 0.4 Bhp 3.18 4.17 5.35 6.72 8.29 10.09 12.12 14.38 16.90 19.67 22.71 26.04 29.65 Rpm 582 630 680 732 784 837 891 946 1000 1056 1111 1167 1224 2.2 Rpm 923 949 978 1010 1046 1084 1124 1166 1210 1255 — — — 0.6 Bhp 3.58 4.60 5.80 7.20 8.80 10.62 12.67 14.96 17.49 20.29 23.35 26.69 30.32 Rpm 626 670 717 766 816 867 919 972 1025 1079 1134 1188 1244 2.4 Bhp 7.57 8.77 10.15 11.74 13.53 15.55 17.79 20.27 23.00 25.99 — — — Rpm 955 980 1008 1038 1072 1109 1148 1189 1231 1276 — — — 0.8 Bhp 3.99 5.04 6.27 7.69 9.32 11.16 13.23 15.54 18.09 20.91 23.99 27.35 31.00 Rpm 668 709 753 799 847 896 946 997 1049 1102 1155 1209 1263 2.6 Bhp 8.05 9.27 10.67 12.27 14.08 16.11 18.38 20.88 23.62 26.63 — — — Rpm 986 1010 1036 1066 1098 1134 1171 1211 1253 1296 — — — 2.8 Bhp 8.54 9.77 11.19 12.81 14.63 16.68 18.97 21.49 24.25 27.27 — — — Rpm 1016 1039 1064 1093 1124 1158 1195 1234 1274 — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.0 1.2 1.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 4.41 708 4.83 747 5.27 785 5.71 5.48 746 5.93 782 6.38 818 6.84 6.73 787 7.20 821 7.68 854 8.16 8.18 831 8.67 863 9.17 893 9.68 9.83 877 10.35 906 10.87 935 11.40 11.70 924 12.24 952 12.78 979 13.33 13.79 973 14.36 999 14.92 1025 15.49 16.12 1023 16.71 1047 17.30 1072 17.89 18.70 1073 19.31 1097 19.92 1120 20.53 21.54 1125 22.17 1147 22.80 1169 23.44 24.64 1177 25.29 1198 25.95 1219 26.60 28.02 1230 28.69 1250 29.37 1270 30.04 31.69 1283 32.38 — — — — Rpm 821 852 886 923 964 1006 1050 1096 1143 1191 1240 1290 — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.0 3.2 3.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 9.03 1045 9.53 1073 10.03 1100 10.54 10.28 1067 10.80 1095 11.32 1122 11.85 11.72 1092 12.25 1119 12.79 1145 13.33 13.35 1119 13.90 1145 14.45 1171 15.01 15.19 1149 15.76 1174 16.32 1199 16.90 17.26 1182 17.84 1206 18.42 1230 19.01 19.55 1218 20.15 1241 20.75 1263 21.35 22.09 1256 22.71 1277 23.32 1299 23.94 24.88 1295 25.51 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Rpm 1126 1148 1171 1196 1223 1253 1285 — — — — — — 1.6 1.8 Bhp 6.16 7.31 8.65 10.18 11.92 13.88 16.06 18.48 21.15 24.07 27.26 30.72 — Rpm 857 885 917 953 991 1032 1075 1120 1165 1213 1261 — — Bhp 11.05 12.38 13.88 15.57 17.48 19.60 21.96 — — — — — — Rpm 1152 1174 1196 1220 1247 1276 — — — — — — — 3.6 2.0 Bhp 6.63 7.79 9.14 10.70 12.46 14.43 16.64 19.08 21.76 24.71 27.92 — — Rpm 891 918 948 982 1019 1058 1100 1143 1188 1234 1281 — — Bhp 11.56 12.91 14.43 16.14 18.06 20.20 — — — — — — — Rpm 1177 1199 1221 1245 1270 1299 — — — — — — — 3.8 Bhp 7.09 8.28 9.65 11.21 12.99 14.99 17.21 19.68 22.38 25.35 28.58 — — 4.0 Bhp 12.08 13.45 14.99 16.72 18.65 20.80 — — — — — — — Table 28 — Fan Performance — 48AW,AY051 Units AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 0.2 Rpm 450 516 550 584 619 654 689 725 760 796 832 869 905 942 978 0.4 Bhp 3.19 4.81 5.80 6.90 8.13 9.49 10.99 12.64 14.43 16.37 18.47 20.74 23.17 25.78 28.56 Rpm 509 569 600 632 664 697 730 764 798 833 867 902 937 973 1008 1.2 Rpm 691 739 764 790 817 845 873 902 932 962 992 1023 1055 1086 1119 1.4 Bhp 6.96 8.79 9.88 11.10 12.44 13.93 15.56 17.34 19.27 21.36 23.61 26.03 28.62 31.38 34.32 Rpm 728 774 799 824 850 877 904 933 961 991 1020 1051 1081 1113 1144 Bhp 11.31 13.42 14.62 15.92 17.36 18.93 20.63 22.48 24.49 26.66 28.99 31.49 34.16 —— Rpm 890 930 952 974 997 1021 1045 1070 1096 1123 1150 1177 — — —- 2.2 Rpm 860 901 923 946 970 994 1019 1045 1071 1098 1125 1153 1181 — — 2.4 3.2 Rpm 998 1036 1056 1077 1099 1121 1144 1167 1192 — — — — — — Rpm 1024 1061 1081 1101 1122 1144 1167 1190 — — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Bhp Rpm Bhp Rpm 7.80 764 8.66 797 9.68 808 10.59 841 10.79 832 11.72 864 12.02 857 12.97 888 13.38 882 14.35 912 14.88 908 15.86 938 16.53 935 17.52 964 18.32 962 19.33 990 20.27 990 21.29 1018 22.38 1019 23.42 1046 24.65 1048 25.71 1074 27.09 1077 28.17 1103 29.70 1107 30.79 1133 32.48 1138 33.59 1163 35.44 1169 36.58 1193 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Rpm Bhp Rpm 918 13.11 946 958 15.36 985 979 16.61 1006 1001 17.97 1027 1024 19.45 1049 1047 21.05 1072 1071 22.79 1096 1096 24.67 1120 1121 26.71 1145 1147 28.90 1171 1173 31.26 1197 — — — — — — — — — — — — 0.8 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Bhp Rpm Bhp Rpm 16.79 1048 17.72 1072 19.33 1085 20.34 1108 20.71 1104 21.75 1128 22.18 1125 23.25 1148 23.76 1146 24.86 1168 25.45 1167 26.58 1190 27.27 1190 28.42 — 29.23 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 20 1.0 Bhp 5.34 7.10 8.15 9.33 10.65 12.10 13.69 15.43 17.32 19.37 21.57 23.94 26.48 29.18 32.07 Rpm 651 701 727 754 782 811 840 870 900 931 963 995 1027 1059 1092 Bhp 9.53 11.52 12.67 13.94 15.33 16.86 18.54 20.36 22.34 24.48 26.78 29.26 31.90 34.72 37.72 Rpm 829 872 894 917 941 966 992 1018 1045 1072 1100 1129 1157 1187 — Bhp 14.02 16.34 17.62 19.01 20.51 22.14 23.89 25.79 27.84 30.05 32.42 — — — — Rpm 973 1011 1031 1052 1074 1097 1120 1144 1169 1194 — — — — — Bhp 18.66 21.35 22.80 24.33 25.97 27.71 — — — — — — — — — Rpm 1096 1131 1150 1170 1191 — — — — — — — — — — 1.8 Bhp 6.14 7.93 9.00 10.20 11.53 13.00 14.61 16.38 18.29 20.36 22.59 24.98 27.55 30.28 33.20 2.0 2.8 Bhp 12.21 14.38 15.61 16.94 18.40 19.98 21.70 23.57 25.59 27.77 30.12 32.63 — — — 3.4 Bhp 15.86 18.33 19.67 21.12 22.67 24.34 26.13 28.07 30.16 — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 3.86 561 4.58 608 5.54 617 6.30 660 6.56 646 7.34 688 7.69 676 8.50 716 8.96 706 9.79 745 10.36 737 11.22 775 11.90 769 12.79 806 13.58 801 14.51 837 15.41 834 16.37 868 17.39 867 18.39 900 19.54 901 20.56 932 21.84 934 22.90 965 24.31 968 25.40 998 26.95 1003 28.08 1032 29.77 1037 30.93 1065 Bhp 10.42 12.46 13.64 14.92 16.34 17.88 19.58 21.41 23.40 25.56 27.87 30.36 33.02 35.86 — 3.0 3.8 Bhp 14.94 17.33 18.64 20.06 21.58 23.23 25.01 26.93 28.99 31.21 — — — — — 4.0 Bhp 19.60 22.36 23.85 25.42 27.08 — — — — — — — — — — Table 29 — Fan Performance — 48AW,AY,A4,A5060 Units AIRFLOW (Cfm) 12,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 26,000 27,000 AIRFLOW (Cfm) 12,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 26,000 27,000 0.2 Rpm Bhp 516 4.81 584 6.90 619 8.13 654 9.49 689 10.99 725 12.64 760 14.43 796 16.37 832 18.47 869 20.74 905 23.17 942 25.78 978 28.56 1015 31.52 1052 34.66 0.4 Rpm Bhp 569 5.54 632 7.69 664 8.96 697 10.36 730 11.90 764 13.58 798 15.41 833 17.39 867 19.54 902 21.84 937 24.31 973 26.95 1008 29.77 1044 32.76 1080 35.94 0.6 Rpm Bhp 617 6.30 676 8.50 706 9.79 737 11.22 769 12.79 801 14.51 834 16.37 867 18.39 901 20.56 934 22.90 968 25.40 1003 28.08 1037 30.93 1072 33.96 1107 37.18 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 660 7.10 701 7.93 739 8.79 774 9.68 716 9.33 754 10.20 790 11.10 824 12.02 745 10.65 782 11.53 817 12.44 850 13.38 775 12.10 811 13.00 845 13.93 877 14.88 806 13.69 840 14.61 873 15.56 904 16.53 837 15.43 870 16.38 902 17.34 933 18.32 868 17.32 900 18.29 932 19.27 961 20.27 900 19.37 931 20.36 962 21.36 991 22.38 932 21.57 963 22.59 992 23.61 1020 24.65 965 23.94 995 24.98 1023 26.03 1051 27.09 998 26.48 1027 27.55 1055 28.62 1081 29.70 1032 29.18 1059 30.28 1086 31.38 1113 32.48 1065 32.07 1092 33.20 1119 34.32 1144 35.44 1099 35.13 1125 36.29 1151 37.44 1176 38.59 1133 38.38 1159 39.57 1184 40.75 — — 1.6 Rpm Bhp 808 10.59 857 12.97 882 14.35 908 15.86 935 17.52 962 19.33 990 21.29 1019 23.42 1048 25.71 1077 28.17 1107 30.79 1138 33.59 1169 36.58 — — — — 1.8 Rpm Bhp 841 11.52 888 13.94 912 15.33 938 16.86 964 18.54 990 20.36 1018 22.34 1046 24.48 1074 26.78 1103 29.26 1133 31.90 1163 34.72 1193 37.72 — — — — 2.0 Rpm Bhp 872 12.46 917 14.92 941 16.34 966 17.88 992 19.58 1018 21.41 1045 23.40 1072 25.56 1100 27.87 1129 30.36 1157 33.02 1187 35.86 — — — — — — 2.2 Rpm Bhp 901 13.42 946 15.92 970 17.36 994 18.93 1019 20.63 1045 22.48 1071 24.49 1098 26.66 1125 28.99 1153 31.49 1181 34.16 — — — — — — — — 2.4 Rpm Bhp 930 14.38 974 16.94 997 18.40 1021 19.98 1045 21.70 1070 23.57 1096 25.59 1123 27.77 1150 30.12 1177 32.63 — — — — — — — — — — 2.6 Rpm Bhp 958 15.36 1001 17.97 1024 19.45 1047 21.05 1071 22.79 1096 24.67 1121 26.71 1147 28.90 1173 31.26 — — — — — — — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 985 16.34 1011 17.33 1036 18.33 1061 19.33 1027 19.01 1052 20.06 1077 21.12 1101 22.18 1049 20.51 1074 21.58 1099 22.67 1122 23.76 1072 22.14 1097 23.23 1121 24.34 1144 25.45 1096 23.89 1120 25.01 1144 26.13 1167 27.27 1120 25.79 1144 26.93 1167 28.07 1190 29.23 1145 27.84 1169 28.99 1192 30.16 — — 1171 30.05 1194 31.21 — — — — 1197 32.42 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 3.6 Rpm Bhp 1085 20.34 1125 23.25 1146 24.86 1167 26.58 1190 28.42 — — — — — — — — — — — — — — — — — — — — 3.8 Rpm Bhp 1108 21.35 1148 24.33 1168 25.97 1190 27.71 — — — — — — — — — — — — — — — — — — — — — — 4.0 Rpm Bhp 1131 22.36 1170 25.42 1191 27.08 — — — — — — — — — — — — — — — — — — — — — — — — Table 30 — Fan Performance — 50AW,AY020,025 and 50A4,A5020 Units AIRFLOW (CFM) 4,000 5,000 6,000 7,000 7,500 8,000 9,000 10,000 11,000 12,000 12,500 13,000 AIRFLOW (CFM) 0.2 Rpm Bhp 322 0.62 361 0.95 405 1.41 451 2.00 475 2.34 500 2.72 550 3.60 601 4.63 653 5.83 706 7.20 732 7.96 759 8.76 2.2 Rpm Bhp 4,000 808 2.84 5,000 829 3.39 6,000 849 4.02 7,000 871 4.74 7,500 883 5.14 8,000 896 5.58 9,000 924 6.54 10,000 954 7.64 11,000 987 8.89 12,000 1022 10.31 12,500 1039 11.08 13,000 1058 11.90 LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb 0.4 Rpm Bhp 399 0.82 431 1.17 467 1.64 508 2.22 529 2.57 551 2.95 596 3.83 644 4.86 692 6.07 742 7.45 768 8.20 793 9.01 0.6 Rpm Bhp 464 1.04 491 1.41 524 1.88 559 2.48 579 2.82 598 3.21 640 4.09 684 5.12 730 6.33 777 7.71 801 8.47 826 9.27 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 521 1.26 572 1.48 619 1.71 662 1.93 545 1.65 594 1.89 640 2.14 682 2.39 574 2.14 621 2.40 664 2.67 705 2.93 607 2.75 651 3.02 693 3.30 732 3.58 625 3.10 668 3.38 708 3.66 746 3.96 643 3.48 685 3.77 724 4.06 762 4.36 682 4.36 721 4.66 759 4.96 795 5.27 723 5.40 760 5.70 796 6.01 830 6.33 766 6.61 801 6.91 835 7.22 867 7.54 811 7.99 844 8.29 875 8.61 906 8.93 834 8.75 866 9.05 897 9.37 927 9.69 857 9.56 888 9.86 918 10.17 947 10.50 1.6 Rpm Bhp 702 2.16 722 2.64 744 3.20 769 3.87 783 4.25 797 4.66 829 5.58 863 6.65 899 7.87 936 9.27 956 10.03 976 10.84 1.8 Rpm Bhp 739 2.38 759 2.89 780 3.47 804 4.16 818 4.55 832 4.96 862 5.90 894 6.98 929 8.21 966 9.61 985 10.38 1004 11.19 2.0 Rpm Bhp 774 2.61 795 3.14 816 3.75 839 4.45 851 4.84 864 5.27 893 6.22 925 7.31 958 8.55 994 9.96 1012 10.73 1031 11.54 2.4 Rpm Bhp 840 3.06 861 3.64 881 4.29 903 5.03 915 5.44 927 5.89 954 6.86 983 7.98 1015 9.24 1048 10.67 1066 11.44 1084 12.26 2.6 Rpm Bhp 870 3.29 892 3.89 912 4.57 933 5.33 945 5.75 957 6.20 983 7.19 1011 8.31 1042 9.59 1075 11.03 1092 11.81 1109 12.63 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 900 3.52 928 3.75 955 3.98 981 4.21 922 4.14 950 4.40 978 4.65 1005 4.90 942 4.84 971 5.12 999 5.39 1026 5.67 963 5.62 991 5.92 1019 6.21 1046 6.51 974 6.05 1002 6.35 1030 6.66 1057 6.96 985 6.51 1014 6.82 1041 7.13 1067 7.45 1011 7.51 1038 7.84 1064 8.17 1090 8.50 1038 8.65 1065 8.99 1091 9.34 1116 9.68 1068 9.94 1094 10.29 1119 10.65 1144 11.01 1100 11.39 1125 11.75 1150 12.12 1173 12.48 1117 12.17 1141 12.54 1165 12.91 1189 13.28 1134 13.00 1158 13.37 1182 13.75 — — 3.6 Rpm Bhp 1007 4.44 1031 5.16 1052 5.94 1072 6.80 1083 7.27 1093 7.76 1116 8.83 1141 10.02 1168 11.36 1197 12.85 — — — — 3.8 Rpm Bhp 1031 4.67 1056 5.41 1077 6.22 1098 7.10 1108 7.58 1118 8.08 1141 9.16 1165 10.37 1191 11.72 — — — — — — 4.0 Rpm Bhp 1055 4.91 1080 5.67 1102 6.49 1123 7.40 1133 7.88 1143 8.39 1165 9.49 1189 10.72 — — — — — — — — 2. Conversion — Bhp to watts: Watts = NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. Bhp x 746 Motor efficiency 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. 21 Table 31 — Fan Performance — 50AW,AY027,030 and 50A4,A5025-030 Units AIRFLOW (CFM) 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 AIRFLOW (CFM) 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 0.2 Rpm Bhp 325 0.62 366 0.97 411 1.43 459 2.02 508 2.76 560 3.64 612 4.68 665 5.89 718 7.28 772 8.85 826 10.61 881 12.57 0.4 Rpm Bhp 402 0.83 435 1.19 473 1.66 515 2.25 559 2.99 605 3.88 654 4.92 703 6.14 754 7.53 806 9.11 858 10.87 910 12.84 0.6 Rpm Bhp 466 1.05 495 1.42 529 1.91 566 2.51 606 3.25 649 4.14 694 5.19 740 6.41 788 7.80 838 9.38 888 11.15 939 13.12 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 523 1.27 574 1.49 620 1.72 663 1.94 548 1.67 597 1.91 642 2.16 685 2.41 579 2.16 625 2.43 668 2.69 709 2.96 613 2.78 657 3.06 698 3.34 737 3.62 650 3.53 691 3.82 731 4.11 768 4.41 690 4.42 729 4.72 766 5.02 802 5.33 732 5.47 769 5.77 804 6.09 838 6.40 776 6.69 811 7.00 844 7.31 876 7.64 822 8.09 854 8.39 886 8.71 916 9.04 869 9.67 899 9.98 929 10.30 958 10.63 917 11.44 946 11.75 974 12.07 1002 12.41 967 13.41 994 13.72 1021 14.05 1047 14.38 1.6 Rpm Bhp 703 2.17 724 2.65 747 3.23 774 3.91 803 4.71 835 5.64 870 6.73 907 7.97 946 9.38 987 10.97 1029 12.75 1073 14.73 1.8 Rpm Bhp 740 2.39 762 2.90 784 3.50 809 4.20 837 5.01 868 5.96 902 7.06 937 8.31 975 9.72 1014 11.32 1055 13.10 1098 15.08 2.0 Rpm Bhp 776 2.62 797 3.16 819 3.77 843 4.49 870 5.32 900 6.28 932 7.39 967 8.65 1003 10.07 1041 11.68 1081 13.46 1123 15.45 2.2 Rpm Bhp 809 2.84 831 3.41 852 4.05 875 4.78 901 5.63 930 6.60 961 7.72 995 8.99 1030 10.43 1068 12.04 1107 13.83 1147 15.82 2.4 Rpm Bhp 841 3.07 863 3.66 884 4.32 907 5.07 932 5.94 960 6.93 990 8.06 1022 9.34 1057 10.78 1093 12.40 1131 14.20 1171 16.19 2.6 Rpm Bhp 872 3.30 894 3.91 915 4.59 937 5.37 961 6.25 988 7.25 1018 8.40 1049 9.69 1083 11.14 1119 12.77 1156 14.58 1194 16.58 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 901 3.53 929 3.76 956 3.99 982 4.22 924 4.16 952 4.41 980 4.67 1007 4.92 945 4.87 974 5.14 1001 5.42 1028 5.69 967 5.66 995 5.95 1023 6.25 1049 6.55 990 6.56 1018 6.87 1045 7.18 1072 7.50 1016 7.58 1043 7.91 1070 8.23 1096 8.57 1045 8.74 1071 9.08 1097 9.42 1122 9.76 1075 10.04 1101 10.39 1126 10.75 1151 11.11 1108 11.51 1133 11.87 1157 12.24 1181 12.61 1143 13.14 1167 13.52 1191 13.89 — — 1179 14.96 — — — — — — — — — — — — — — 3.6 Rpm Bhp 1008 4.45 1032 5.17 1054 5.97 1076 6.84 1097 7.81 1121 8.90 1147 10.11 1175 11.47 — — — — — — — — 3.8 Rpm Bhp 1032 4.68 1057 5.43 1080 6.24 1101 7.14 1123 8.13 1146 9.23 1171 10.46 1198 11.82 — — — — — — — — 4.0 Rpm Bhp 1056 4.92 1082 5.68 1105 6.52 1126 7.44 1147 8.44 1170 9.56 1194 10.80 — — — — — — — — — — Table 32 — Fan Performance — 50AW,AY,A4,A5035 Units AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 10,500 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 7,000 8,000 9,000 10,000 10,500 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 0.2 Rpm Bhp 522 2.06 576 2.75 630 3.57 686 4.52 714 5.05 742 5.62 799 6.88 856 8.29 914 9.87 971 11.62 1029 13.55 1088 15.66 1117 16.79 0.4 Rpm Bhp 573 2.32 622 3.03 672 3.86 724 4.84 750 5.38 777 5.95 831 7.22 886 8.65 942 10.24 998 12.00 1054 13.94 1111 16.07 1140 17.20 0.6 Rpm Bhp 620 2.57 665 3.30 712 4.16 761 5.15 786 5.70 811 6.28 863 7.57 916 9.01 969 10.61 1024 12.39 1079 14.34 1134 16.47 1162 17.61 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 664 2.82 705 3.06 744 3.30 780 3.54 706 3.57 745 3.84 782 4.10 817 4.36 750 4.45 787 4.74 822 5.02 855 5.30 797 5.46 831 5.77 864 6.07 896 6.37 821 6.02 854 6.34 886 6.65 917 6.96 845 6.61 877 6.94 909 7.26 939 7.58 894 7.91 925 8.25 954 8.60 983 8.93 945 9.37 974 9.72 1002 10.08 1029 10.44 997 10.98 1024 11.36 1050 11.73 1076 12.10 1050 12.77 1075 13.16 1100 13.54 1125 13.93 1103 14.74 1127 15.13 1151 15.53 1174 15.93 1157 16.88 1180 17.29 1203 17.70 1225 18.11 1184 18.02 1207 18.44 1229 18.86 1250 19.27 1.6 Rpm Bhp 815 3.78 850 4.62 888 5.58 927 6.67 947 7.27 968 7.90 1011 9.27 1056 10.79 1102 12.47 1149 14.31 1198 16.33 1247 18.53 1272 19.69 1.8 Rpm Bhp 849 4.01 883 4.87 919 5.86 957 6.97 977 7.57 997 8.21 1039 9.60 1082 11.14 1127 12.84 1173 14.70 1220 16.73 1269 18.93 1293 20.11 2.0 Rpm Bhp 881 4.24 914 5.12 949 6.13 986 7.26 1005 7.87 1025 8.52 1065 9.93 1108 11.49 1152 13.20 1197 15.08 1243 17.12 1290 19.34 — — 2.2 Rpm Bhp 912 4.46 944 5.37 978 6.40 1014 7.55 1033 8.17 1052 8.83 1091 10.26 1133 11.83 1176 13.56 1220 15.45 1265 17.52 — — — — 2.4 Rpm Bhp 942 4.68 973 5.62 1006 6.67 1041 7.84 1059 8.47 1078 9.14 1117 10.58 1157 12.17 1199 13.92 1243 15.83 1287 17.91 — — — — 2.6 Rpm Bhp 970 4.90 1001 5.86 1034 6.93 1068 8.12 1086 8.77 1104 9.44 1142 10.90 1181 12.51 1222 14.28 1265 16.20 — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 998 5.12 1025 5.33 1051 5.54 1076 5.75 1029 6.11 1055 6.35 1081 6.58 1106 6.82 1060 7.20 1086 7.46 1112 7.72 1136 7.98 1094 8.41 1119 8.69 1144 8.97 1168 9.25 1111 9.06 1136 9.35 1161 9.64 1184 9.93 1129 9.75 1154 10.05 1178 10.35 1201 10.64 1166 11.23 1190 11.54 1213 11.86 1236 12.18 1205 12.85 1228 13.19 1251 13.52 1273 13.86 1245 14.63 1268 14.99 1290 15.34 — — 1287 16.58 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 3.6 Rpm Bhp 1101 5.96 1130 7.05 1160 8.23 1192 9.52 1208 10.22 1224 10.94 1259 12.49 1295 14.19 — — — — — — — — — — 3.8 Rpm Bhp 1124 6.16 1154 7.28 1184 8.49 1215 9.80 1231 10.50 1247 11.23 1281 12.80 — — — — — — — — — — — — 4.0 Rpm Bhp 1148 6.36 1177 7.51 1207 8.74 1238 10.07 1253 10.79 1269 11.53 — — — — — — — — — — — — — — LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb 2. Conversion — Bhp to watts: NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. Watts = 22 Bhp x 746 Motor efficiency Table 33 — Fan Performance — 50AW,AY036 Units AIRFLOW (Cfm) 0.2 Rpm 451 499 548 599 649 701 753 805 857 910 963 989 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 0.4 Bhp 2.13 2.88 3.78 4.86 6.11 7.54 9.18 11.03 13.09 15.38 17.91 19.26 Rpm 503 546 591 637 685 734 783 833 884 935 986 1012 1.2 Rpm 682 711 744 779 817 857 899 942 987 1032 1078 1102 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 1.4 Bhp 3.99 4.87 5.90 7.09 8.47 10.02 11.77 13.73 15.89 18.28 20.91 22.31 Rpm 722 748 778 812 848 886 927 968 1011 1056 1101 1124 2.2 Rpm 866 885 908 934 964 996 1031 1068 1106 1146 1187 1208 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 AIRFLOW (Cfm) 2.4 Bhp 6.09 7.03 8.13 9.42 10.89 12.55 14.41 16.48 18.75 21.25 23.98 25.43 Rpm 899 917 939 963 992 1023 1056 1092 1129 1168 1208 1229 3.2 Rpm 1020 1036 1053 1073 1097 1123 1152 1184 1217 1253 1289 — 7,000 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 17,500 3.4 Bhp 8.39 9.39 10.55 11.89 13.43 15.17 17.12 19.27 21.65 24.25 27.07 — Rpm 1047 1063 1080 1100 1122 1147 1175 1206 1239 1273 — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 2.49 552 2.86 597 3.27 590 3.66 632 4.20 631 4.62 670 5.30 675 5.74 711 6.57 720 7.04 753 8.03 766 8.52 797 9.69 813 10.21 842 11.56 861 12.09 889 13.64 910 14.20 936 15.95 960 16.53 984 18.50 1010 19.09 1033 19.86 1035 20.47 1058 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Bhp Rpm Bhp Rpm 4.39 760 4.80 797 5.28 784 5.70 819 6.33 812 6.77 845 7.55 844 8.01 875 8.94 878 9.43 907 10.52 915 11.03 943 12.30 953 12.82 980 14.27 994 14.82 1019 16.46 1036 17.03 1060 18.87 1079 19.47 1101 21.52 1123 22.13 1145 22.93 1145 23.55 1166 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Bhp Rpm Bhp Rpm 6.54 931 6.99 961 7.48 948 7.95 978 8.60 968 9.08 997 9.90 992 10.39 1020 11.39 1019 11.89 1045 13.07 1048 13.59 1074 14.95 1081 15.48 1105 17.03 1115 17.59 1138 19.33 1151 19.91 1174 21.85 1189 22.45 1211 24.60 1229 25.21 1249 26.06 1249 26.69 1269 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Bhp Rpm Bhp Rpm 8.86 1074 9.34 1101 9.88 1090 10.38 1116 11.05 1107 11.56 1133 12.41 1125 12.93 1151 13.96 1147 14.49 1171 15.71 1171 16.25 1195 17.67 1198 18.22 1221 19.84 1228 20.41 1250 22.23 1260 22.82 1280 24.85 1293 25.45 — — — — — — — — — 0.8 1.0 Bhp 3.23 4.06 5.04 6.19 7.51 9.02 10.72 12.63 14.76 17.11 19.69 21.08 Rpm 641 672 708 746 786 828 871 916 962 1008 1056 1080 Bhp 5.22 6.14 7.22 8.47 9.91 11.53 13.35 15.37 17.61 20.06 22.75 24.18 Rpm 832 853 877 905 936 970 1006 1044 1083 1124 1166 1187 Bhp 7.45 8.42 9.56 10.89 12.40 14.11 16.03 18.15 20.48 23.04 25.83 27.32 Rpm 991 1007 1026 1047 1071 1099 1129 1161 1196 1232 1270 1289 Bhp 9.83 10.88 12.08 13.45 15.02 16.80 18.78 20.99 23.41 — — — Rpm 1126 1142 1158 1175 1195 1218 1243 1271 — — — — 1.8 Bhp 3.60 4.46 5.47 6.64 7.99 9.52 11.25 13.18 15.32 17.69 20.30 21.69 2.0 2.8 Bhp 5.65 6.58 7.67 8.94 10.40 12.04 13.88 15.92 18.18 20.66 23.36 24.80 3.0 3.8 Bhp 7.91 8.90 10.05 11.39 12.91 14.64 16.57 18.71 21.07 23.64 26.46 27.95 4.0 Bhp 10.32 11.39 12.60 13.99 15.56 17.35 19.35 21.56 — — — — Table 34 — Fan Performance — 50AW,AY,A4,A5040 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 499 548 599 649 701 753 805 857 910 963 1016 1069 1122 Bhp 2.88 3.78 4.86 6.11 7.54 9.18 11.03 13.09 15.38 17.91 20.68 23.71 26.99 0.4 Rpm 546 591 637 685 734 783 833 884 935 986 1038 1090 1142 2.2 Rpm 885 908 934 964 996 1031 1068 1106 1146 1187 1230 — — Bhp 7.03 8.13 9.42 10.89 12.55 14.41 16.48 18.75 21.25 23.98 26.95 — — Bhp 3.27 4.20 5.30 6.57 8.03 9.69 11.56 13.64 15.95 18.50 21.29 24.33 27.64 0.6 Rpm 590 631 675 720 766 813 861 910 960 1010 1060 1111 1162 2.4 Rpm 917 939 963 992 1023 1056 1092 1129 1168 1208 1250 — — Bhp 7.48 8.60 9.90 11.39 13.07 14.95 17.03 19.33 21.85 24.60 27.58 — — Bhp 3.66 4.62 5.74 7.04 8.52 10.21 12.09 14.20 16.53 19.09 21.90 24.96 28.29 2.6 Rpm 948 968 992 1019 1048 1081 1115 1151 1189 1229 1269 — — Bhp 7.95 9.08 10.39 11.89 13.59 15.48 17.59 19.91 22.45 25.21 28.22 — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 632 4.06 672 4.46 711 4.87 748 5.28 670 5.04 708 5.47 744 5.90 778 6.33 711 6.19 746 6.64 779 7.09 812 7.55 753 7.51 786 7.99 817 8.47 848 8.94 797 9.02 828 9.52 857 10.02 886 10.52 842 10.72 871 11.25 899 11.77 927 12.30 889 12.63 916 13.18 942 13.73 968 14.27 936 14.76 962 15.32 987 15.89 1011 16.46 984 17.11 1008 17.69 1032 18.28 1056 18.87 1033 19.69 1056 20.30 1078 20.91 1101 21.52 1082 22.52 1104 23.15 1126 23.77 1147 24.41 1132 25.60 1153 26.25 1173 26.89 1194 27.54 1182 28.95 — — — — — — Rpm 784 812 844 878 915 953 994 1036 1079 1123 1168 1214 — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.8 3.0 3.2 3.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 978 8.42 1007 8.90 1036 9.39 1063 9.88 997 9.56 1026 10.05 1053 10.55 1080 11.05 1020 10.89 1047 11.39 1073 11.89 1100 12.41 1045 12.40 1071 12.91 1097 13.43 1122 13.96 1074 14.11 1099 14.64 1123 15.17 1147 15.71 1105 16.03 1129 16.57 1152 17.12 1175 17.67 1138 18.15 1161 18.71 1184 19.27 1206 19.84 1174 20.48 1196 21.07 1217 21.65 1239 22.23 1211 23.04 1232 23.64 1253 24.25 1273 24.85 1249 25.83 1270 26.46 1289 27.07 — — 1289 28.86 — — — — — — — — — — — — — — — — — — — — — — Rpm 1090 1107 1125 1147 1171 1198 1228 1260 1293 — — — — LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. 1.6 Bhp 5.70 6.77 8.01 9.43 11.03 12.82 14.82 17.03 19.47 22.13 25.04 28.19 — 1.8 Rpm 819 845 875 907 943 980 1019 1060 1101 1145 1189 1234 — 3.6 Bhp 10.38 11.56 12.93 14.49 16.25 18.22 20.41 22.82 25.45 — — — — Bhp 6.14 7.22 8.47 9.91 11.53 13.35 15.37 17.61 20.06 22.75 25.67 28.85 — 2.0 Rpm 853 877 905 936 970 1006 1044 1083 1124 1166 1209 — — 3.8 Rpm 1116 1133 1151 1171 1195 1221 1250 1280 — — — — — Bhp 10.88 12.08 13.45 15.02 16.80 18.78 20.99 23.41 — — — — — Bhp 6.58 7.67 8.94 10.40 12.04 13.88 15.92 18.18 20.66 23.36 26.31 — — 4.0 Rpm 1142 1158 1175 1195 1218 1243 1271 — — — — — — Bhp 11.39 12.60 13.99 15.56 17.35 19.35 21.56 — — — — — — 2. Conversion — Bhp to watts: Watts = Bhp x 746 Motor efficiency 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additional limited by edb and ewb conditions. 23 Table 35 — Fan Performance — 50AW,AY041 Units AIRFLOW (Cfm) 0.2 Rpm 499 548 599 649 701 753 805 857 910 963 1016 1069 1122 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) Rpm 546 591 637 685 734 783 833 884 935 986 1038 1090 1142 Bhp 4.87 5.90 7.09 8.47 10.02 11.77 13.73 15.89 18.28 20.91 23.77 26.89 — Rpm 748 778 812 848 886 927 968 1011 1056 1101 1147 1194 — Bhp 7.03 8.13 9.42 10.89 12.55 14.41 16.48 18.75 21.25 23.98 26.95 — — Rpm 917 939 963 992 1023 1056 1092 1129 1168 1208 1250 — — Bhp 9.39 10.55 11.89 13.43 15.17 17.12 19.27 21.65 24.25 27.07 — — — Rpm 1063 1080 1100 1122 1147 1175 1206 1239 1273 — — — — 1.2 Rpm 711 744 779 817 857 899 942 987 1032 1078 1126 1173 — 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Rpm Bhp Rpm 784 5.70 819 812 6.77 845 844 8.01 875 878 9.43 907 915 11.03 943 953 12.82 980 994 14.82 1019 1036 17.03 1060 1079 19.47 1101 1123 22.13 1145 1168 25.04 1189 1214 28.19 1234 — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Rpm Bhp Rpm 948 7.95 978 968 9.08 997 992 10.39 1020 1019 11.89 1045 1048 13.59 1074 1081 15.48 1105 1115 17.59 1138 1151 19.91 1174 1189 22.45 1211 1229 25.21 1249 1269 28.22 1289 — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Rpm Bhp Rpm 1090 10.38 1116 1107 11.56 1133 1125 12.93 1151 1147 14.49 1171 1171 16.25 1195 1198 18.22 1221 1228 20.41 1250 1260 22.82 1280 1293 25.45 — — — — — — — — — — — — — Rpm 672 708 746 786 828 871 916 962 1008 1056 1104 1153 — Bhp 6.14 7.22 8.47 9.91 11.53 13.35 15.37 17.61 20.06 22.75 25.67 28.85 — Rpm 853 877 905 936 970 1006 1044 1083 1124 1166 1209 — — Bhp 8.42 9.56 10.89 12.40 14.11 16.03 18.15 20.48 23.04 25.83 28.86 — — Rpm 1007 1026 1047 1071 1099 1129 1161 1196 1232 1270 — — — Bhp 10.88 12.08 13.45 15.02 16.80 18.78 20.99 23.41 — — — — — Rpm 1142 1158 1175 1195 1218 1243 1271 — — — — — — Bhp 6.58 7.67 8.94 10.40 12.04 13.88 15.92 18.18 20.66 23.36 26.31 — — 3.0 3.8 Bhp 9.88 11.05 12.41 13.96 15.71 17.67 19.84 22.23 24.85 — — — — Bhp 4.46 5.47 6.64 7.99 9.52 11.25 13.18 15.32 17.69 20.30 23.15 26.25 — 2.0 2.8 Bhp 7.48 8.60 9.90 11.39 13.07 14.95 17.03 19.33 21.85 24.60 27.58 — — 3.4 1.0 Bhp 4.06 5.04 6.19 7.51 9.02 10.72 12.63 14.76 17.11 19.69 22.52 25.60 28.95 1.8 Bhp 5.28 6.33 7.55 8.94 10.52 12.30 14.27 16.46 18.87 21.52 24.41 27.54 — 2.4 3.2 Rpm 1036 1053 1073 1097 1123 1152 1184 1217 1253 1289 — — — 0.8 Bhp 3.27 4.20 5.30 6.57 8.03 9.69 11.56 13.64 15.95 18.50 21.29 24.33 27.64 1.4 2.2 Rpm 885 908 934 964 996 1031 1068 1106 1146 1187 1230 — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Rpm Bhp Rpm 590 3.66 632 631 4.62 670 675 5.74 711 720 7.04 753 766 8.52 797 813 10.21 842 861 12.09 889 910 14.20 936 960 16.53 984 1010 19.09 1033 1060 21.90 1082 1111 24.96 1132 1162 28.29 1182 0.4 Bhp 2.88 3.78 4.86 6.11 7.54 9.18 11.03 13.09 15.38 17.91 20.68 23.71 26.99 Bhp 8.90 10.05 11.39 12.91 14.64 16.57 18.71 21.07 23.64 26.46 — — — 4.0 Bhp 11.39 12.60 13.99 15.56 17.35 19.35 21.56 — — — — — — Table 36 — Fan Performance — 50AW,AY,A4,A5050 Units AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 AIRFLOW (Cfm) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 0.2 Rpm 509 558 608 659 710 763 815 868 921 974 1028 1081 1135 0.4 Bhp 2.95 3.87 4.96 6.23 7.68 9.35 11.22 13.31 15.64 18.20 21.01 24.08 27.42 Rpm 555 600 646 694 743 793 843 895 946 998 1050 1103 1155 Bhp 7.12 8.23 9.53 11.02 12.70 14.59 16.68 18.98 21.52 24.28 27.29 30.55 — Rpm 923 945 970 999 1030 1064 1100 1138 1178 1218 1260 — — 2.2 Rpm 892 915 941 971 1004 1039 1076 1115 1156 1198 1240 1284 — 0.6 Bhp 3.35 4.29 5.40 6.69 8.17 9.86 11.75 13.86 16.21 18.79 21.62 24.71 28.06 Rpm 599 640 683 728 775 823 871 921 971 1021 1072 1124 1175 Bhp 7.57 8.70 10.02 11.52 13.22 15.12 17.23 19.56 22.11 24.90 27.93 — — Rpm 954 975 998 1026 1056 1088 1123 1160 1199 1239 1280 — — 2.4 0.8 Bhp 3.74 4.71 5.85 7.16 8.67 10.37 12.29 14.42 16.78 19.39 22.24 25.35 28.72 Rpm 640 678 719 762 806 852 899 946 995 1044 1094 1145 1195 Bhp 8.04 9.18 10.51 12.02 13.74 15.66 17.79 20.14 22.71 25.52 28.57 — — Rpm 984 1003 1026 1052 1081 1113 1147 1182 1220 1259 1300 — — 2.6 2.8 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.0 1.2 1.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 4.14 680 4.54 718 4.95 755 5.36 5.13 715 5.56 751 5.99 786 6.42 6.30 754 6.75 787 7.20 819 7.66 7.64 794 8.11 825 8.59 856 9.07 9.17 836 9.67 866 10.17 895 10.67 10.89 880 11.42 908 11.94 935 12.47 12.83 925 13.38 952 13.92 978 14.47 14.98 972 15.55 997 16.12 1021 16.69 17.37 1019 17.96 1043 18.54 1066 19.14 19.99 1067 20.60 1089 21.21 1112 21.82 22.86 1116 23.49 1137 24.12 1158 24.75 25.99 1165 26.63 1185 27.28 1206 27.93 29.38 1215 30.04 1234 30.71 1254 31.38 Rpm 791 819 851 886 923 962 1003 1045 1089 1134 1179 1226 1273 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.0 3.2 3.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 8.52 1013 9.00 1041 9.49 1069 9.98 9.67 1032 10.16 1059 10.66 1086 11.16 11.00 1053 11.51 1080 12.01 1106 12.53 12.53 1078 13.05 1103 13.57 1128 14.09 14.26 1106 14.79 1130 15.33 1154 15.86 16.20 1136 16.74 1160 17.29 1183 17.85 18.35 1169 18.91 1192 19.48 1214 20.04 20.72 1204 21.30 1226 21.88 1247 22.47 23.31 1241 23.91 1262 24.51 1282 25.12 26.14 1279 26.76 1299 27.38 — — 29.21 — — — — — — — — — — — — — — — — — — — — Rpm 1095 1112 1131 1153 1178 1206 1236 1268 — — — — — 1.6 1.8 Bhp 5.79 6.87 8.12 9.55 11.17 12.99 15.02 17.26 19.73 22.43 25.38 28.58 32.05 Rpm 826 852 882 915 950 988 1028 1069 1111 1155 1200 1245 1292 Bhp 10.48 11.67 13.05 14.63 16.41 18.40 20.62 23.05 — — — — — Rpm 1121 1138 1156 1177 1201 1228 1257 1289 — — — — — 3.6 2.0 Bhp 6.22 7.31 8.58 10.04 11.68 13.52 15.57 17.83 20.32 23.05 26.02 29.24 32.72 Rpm 859 884 912 943 978 1014 1052 1092 1134 1176 1220 1265 — Bhp 10.98 12.19 13.58 15.16 16.96 18.96 21.19 23.65 — — — — — Rpm 1147 1163 1181 1201 1224 1250 1279 — — — — — — 3.8 Bhp 6.66 7.77 9.06 10.53 12.19 14.05 16.12 18.41 20.92 23.66 26.65 29.90 — 4.0 Bhp 11.49 12.71 14.11 15.71 17.51 19.53 21.77 — — — — — — 2. Conversion — Bhp to watts: LEGEND Bhp — Brake Horsepower edb — Entering Dry Bulb ewb — Entering Wet Bulb Watts = NOTES: 1. Fan performance is based on wet coils, economizer, roof curb, cabinet losses, and clean 2-in. filters. Bhp x 746 Motor efficiency 3. Variable air volume units will operate down to 70 cfm/ton. Performance at 70 cfm/ton is limited to unloaded operation and may be additionally limited by edb and ewb conditions. 24 Table 37 — Fan Performance — 50AW,AY051 Units AIRFLOW (Cfm) 0.2 Rpm 429 490 522 554 586 619 652 685 719 753 787 821 855 889 924 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 0.4 Bhp 2.98 4.48 5.39 6.41 7.56 8.83 10.23 11.76 13.44 15.26 17.23 19.35 21.63 24.07 26.67 Rpm 488 543 572 602 632 663 694 725 757 789 822 855 888 921 954 Bhp 6.41 8.14 9.18 10.33 11.60 13.00 14.53 16.20 18.00 19.94 22.03 24.28 26.68 29.24 31.96 Rpm 703 746 769 792 816 841 867 893 920 947 975 1003 1032 1061 1090 1.2 Rpm 666 711 734 759 784 810 836 863 890 918 947 976 1005 1035 1065 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 AIRFLOW (Cfm) Bhp 10.46 12.33 13.44 14.67 16.02 17.51 19.13 20.89 22.80 24.85 27.04 29.39 31.90 34.57 37.41 Rpm 860 898 918 939 961 983 1006 1029 1053 1078 1103 1129 1155 1181 — Bhp 14.94 16.96 18.13 19.42 20.83 22.39 24.07 25.91 27.89 30.01 32.30 — — — — Rpm 991 1026 1044 1063 1083 1104 1125 1147 1169 1192 — — — — — 10,000 12,000 13,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 0.8 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 2.6 Bhp Rpm Bhp Rpm 11.33 888 12.21 915 13.22 925 14.13 951 14.35 945 15.27 971 15.59 965 16.52 991 16.96 987 17.90 1012 18.46 1008 19.42 1033 20.10 1031 21.07 1055 21.87 1054 22.86 1078 23.79 1078 24.80 1101 25.86 1102 26.88 1125 28.07 1126 29.11 1149 30.44 1152 31.50 1174 32.97 1177 34.05 1199 35.66 — — — — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.6 Rpm Bhp Rpm 1014 16.83 1038 1049 18.90 1072 1067 20.10 1090 1086 21.41 1109 1106 22.85 1128 1126 24.43 1148 1147 26.14 1169 1169 28.00 1190 1190 30.00 — — — — — — — — — — — — — — — — — — — 3.4 1.0 Bhp 4.95 6.61 7.61 8.72 9.94 11.30 12.78 14.39 16.14 18.04 20.08 22.28 24.63 27.14 29.82 Rpm 627 673 698 723 749 776 803 831 860 888 918 947 977 1008 1038 Bhp 8.78 10.60 11.68 12.88 14.21 15.66 17.25 18.98 20.84 22.85 25.01 27.32 29.79 32.42 35.21 Rpm 801 841 862 884 906 929 953 978 1003 1028 1054 1081 1108 1135 1163 Bhp 13.11 15.06 16.20 17.47 18.87 20.39 22.06 23.86 25.81 27.91 30.16 32.57 35.13 — — Rpm 941 977 996 1016 1036 1057 1079 1101 1124 1148 1172 1196 — — — Bhp 17.79 19.89 21.10 22.43 23.88 25.47 27.19 29.06 — — — — — — — Rpm 1060 1094 1112 1131 1150 1170 1190 — — — — — — — — 1.8 Bhp 7.17 8.94 9.99 11.16 12.45 13.87 15.42 17.11 18.94 20.90 23.02 25.28 27.71 30.29 33.04 2.4 3.2 Rpm 966 1002 1020 1040 1060 1081 1102 1124 1147 1170 1194 — — — — AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.6 Rpm Bhp Rpm 737 7.96 770 779 9.76 811 801 10.82 832 824 12.01 855 848 13.32 878 872 14.76 901 897 16.33 926 922 18.04 950 949 19.88 976 975 21.87 1002 1002 24.01 1029 1030 26.30 1056 1058 28.75 1083 1086 31.35 1111 1115 34.12 1139 1.4 2.2 Rpm 831 870 891 912 934 957 980 1004 1028 1053 1079 1105 1131 1158 1186 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.6 Bhp Rpm Bhp Rpm 3.61 539 4.26 585 5.17 591 5.88 634 6.11 618 6.85 659 7.17 645 7.94 686 8.34 674 9.14 713 9.64 703 10.46 741 11.07 733 11.92 769 12.63 763 13.51 798 14.33 793 15.23 827 16.18 824 17.10 857 18.17 855 19.12 887 20.32 887 21.29 918 22.62 919 23.62 949 25.08 951 26.11 980 27.71 983 28.76 1011 2.0 2.8 Bhp 9.61 11.45 12.55 13.76 15.11 16.58 18.19 19.93 21.81 23.84 26.02 28.35 30.85 33.49 36.31 3.0 3.8 Bhp 15.88 17.92 19.11 20.41 21.84 23.40 25.10 26.94 28.94 31.08 — — — — — Bhp 5.66 7.36 8.38 9.51 10.77 12.14 13.65 15.29 17.07 18.99 21.05 23.28 25.65 28.19 30.89 Bhp 14.02 16.00 17.16 18.44 19.84 21.38 23.06 24.88 26.84 28.96 31.22 33.65 — — — 4.0 Bhp 18.76 20.89 22.12 23.46 24.92 26.52 28.26 — — — — — — — — Table 38 — Fan Performance — 50AW,AY,A4,A5060 Units AIRFLOW (Cfm) 12,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 26,000 27,000 AIRFLOW (Cfm) 12,000 14,000 15,000 16,000 17,000 18,000 19,000 20,000 21,000 22,000 23,000 24,000 25,000 26,000 27,000 0.2 Rpm 490 554 586 619 652 685 719 753 787 821 855 889 924 958 993 0.4 Bhp 4.48 6.41 7.56 8.83 10.23 11.76 13.44 15.26 17.23 19.35 21.63 24.07 26.67 29.45 32.40 Rpm 543 602 632 663 694 725 757 789 822 855 888 921 954 987 1021 Bhp 12.33 14.67 16.02 17.51 19.13 20.89 22.80 24.85 27.04 29.39 31.90 34.57 37.41 — — Rpm 898 939 961 983 1006 1029 1053 1078 1103 1129 1155 1181 — — — 2.2 Rpm 870 912 934 957 980 1004 1028 1053 1079 1105 1131 1158 1186 — — 0.6 Bhp 5.17 7.17 8.34 9.64 11.07 12.63 14.33 16.18 18.17 20.32 22.62 25.08 27.71 30.51 33.49 Rpm 591 645 674 703 733 763 793 824 855 887 919 951 983 1016 1048 Bhp 13.22 15.59 16.96 18.46 20.10 21.87 23.79 25.86 28.07 30.44 32.97 35.66 — — — Rpm 925 965 987 1008 1031 1054 1078 1102 1126 1152 1177 — — — — 2.4 0.8 Bhp 5.88 7.94 9.14 10.46 11.92 13.51 15.23 17.10 19.12 21.29 23.62 26.11 28.76 31.59 34.58 Rpm 634 686 713 741 769 798 827 857 887 918 949 980 1011 1043 1075 Bhp 14.13 16.52 17.90 19.42 21.07 22.86 24.80 26.88 29.11 31.50 34.05 — — — — Rpm 951 991 1012 1033 1055 1078 1101 1125 1149 1174 1199 — — — — 2.6 2.8 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.0 1.2 1.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 6.61 674 7.37 711 8.14 746 8.94 8.72 723 9.51 759 10.33 792 11.16 9.94 749 10.77 784 11.60 816 12.45 11.30 776 12.14 810 13.00 841 13.87 12.78 803 13.65 836 14.53 867 15.42 14.39 831 15.29 863 16.20 893 17.11 16.14 860 17.07 890 18.00 920 18.94 18.04 888 18.99 918 19.94 947 20.90 20.08 918 21.05 947 22.03 975 23.02 22.28 947 23.28 976 24.28 1003 25.28 24.63 977 25.65 1005 26.68 1032 27.71 27.14 1008 28.19 1035 29.24 1061 30.29 29.82 1038 30.89 1065 31.96 1090 33.04 32.67 1069 33.76 1095 34.85 1120 35.95 35.69 1101 36.80 1126 37.92 1150 39.04 Rpm 779 824 848 872 897 922 949 975 1002 1030 1058 1086 1115 1144 1174 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 3.0 3.2 3.4 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 15.06 977 16.00 1002 16.96 1026 17.92 17.47 1016 18.44 1040 19.42 1063 20.41 18.87 1036 19.84 1060 20.83 1083 21.84 20.39 1057 21.38 1081 22.39 1104 23.40 22.06 1079 23.06 1102 24.07 1125 25.10 23.86 1101 24.88 1124 25.91 1147 26.94 25.81 1124 26.84 1147 27.89 1169 28.94 27.91 1148 28.96 1170 30.01 1192 31.08 30.16 1172 31.22 1194 32.30 — — 32.57 1196 33.65 — — — — 35.13 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Rpm 1049 1086 1106 1126 1147 1169 1190 — — — — — — — — 25 1.6 1.8 Bhp 9.76 12.01 13.32 14.76 16.33 18.04 19.88 21.87 24.01 26.30 28.75 31.35 34.12 37.06 40.17 Rpm 811 855 878 901 926 950 976 1002 1029 1056 1083 1111 1139 1168 1197 Bhp 18.90 21.41 22.85 24.43 26.14 28.00 30.00 — — — — — — — — Rpm 1072 1109 1128 1148 1169 1190 — — — — — — — — — 3.6 2.0 Bhp 10.60 12.88 14.21 15.66 17.25 18.98 20.84 22.85 25.01 27.32 29.79 32.42 35.21 38.17 41.30 Rpm 841 884 906 929 953 978 1003 1028 1054 1081 1108 1135 1163 1191 — Bhp 19.89 22.43 23.88 25.47 27.19 29.06 — — — — — — — — — Rpm 1094 1131 1150 1170 1190 — — — — — — — — — — 3.8 Bhp 11.45 13.76 15.11 16.58 18.19 19.93 21.81 23.84 26.02 28.35 30.85 33.49 36.31 39.29 — 4.0 Bhp 20.89 23.46 24.92 26.52 28.26 — — — — — — — — — — Table 39 — Motor Limitations Nominal Maximum Bhp 5 BkW 3.73 7.5 5.6 10 7.46 15 11.19 20 14.92 25 18.65 30 22.38 40 29.84 Bhp 5.9 8.7 9.5 10.2 11.8 15.3 18.0 22.4 23.4 28.9 29.4 35.6 34.7 42.0 Nominal Bhp 5 BkW 3.73 7.5 5.6 10 7.46 15 11.19 20 14.92 25 18.65 30 22.38 40 29.84 Bhp 5.9 8.7 9.5 10.2 11.8 15.3 18.0 22.4 23.4 28.9 29.4 35.6 34.7 42.0 HIGH-EFFICIENCY MOTORS Maximum Amps BkW 230 v 460 v 4.40 15.0 7.9 6.49 23.5 — 7.09 — 12.0 7.61 31.0 — 8.80 — 15.0 11.41 46.0 — 13.43 — 22.0 16.71 60.0 — 17.46 — 28.7 21.56 73.0 — 21.93 — 37.4 26.56 91.0 — 25.89 — 43.8 31.33 110.0 55.0 PREMIUM-EFFICIENCY MOTORS Maximum Maximum Amps BkW 230 v 460 v 4.40 15.8 7.9 6.49 23.5 — 7.09 — 12.0 7.61 30.0 — 8.80 — 15.0 11.41 46.0 — 13.43 — 22.0 16.71 59.0 — 17.46 — 28.7 21.56 73.0 — 21.93 — 36.3 26.56 82.6 — 25.89 — 41.7 31.33 110.0 55.0 LEGEND — Brake Horsepower — Brake Kilowatts Maximum Watts 5,030 7,717 8,008 9,502 9,836 12,543 14,756 18,363 19,183 23,511 23,918 28,742 28,015 33,690 575 v 6.0 — 10.0 — 12.0 — 19.0 — 23.0 — 28.4 — 36.3 43.8 Maximum Watts 4,918 7,078 7,728 8,298 9,600 12,273 14,439 17,853 18,650 23,034 23,432 28,374 27,656 33,156 Maximum Efficiency 87.5 84.1 88.5 89.5 89.5 91.0 91.0 91.0 91.0 91.7 91.7 92.4 92.4 93.0 Maximum Efficiency 89.5 91.7 91.7 91.0 91.7 91.7 93.0 93.0 93.6 93.6 93.6 93.6 93.6 94.5 Using the fan motors up to the horsepower ratings shown in the Motor Limitations table will not result in nuisance tripping or premature motor failures. Unit warranty will not be affected. 2. All motors comply with Energy Policy Act (EPACT) Standards effective October 24, 1997. Bhp BkW NOTES: 1. Extensive motor and electrical testing on the Carrier units has ensured that the full horsepower range of the motor can be utilized with confidence. Table 40A — Air Quantity Limits (48AJ,AK,AW,AY,A2,A3,A4,A5) UNIT SIZE* 020 025 027 030 035 (AJ,AK,AW,AY) 035 (A2,A3,A4,A5) 036,040,041 050 051,060 MINIMUM HEATING AIRFLOW CFM (Low Heat) 5,900 5,900 5,900 5,900 5,900 5,900 7,600 7,600 11,000 MINIMUM HEATING AIRFLOW CFM (High Heat) 6,100 6,100 6,100 6,100 6,100 10,100 10,100 10,100 10,100 MINIMUM COOLING AIRFLOW (VAV) CFM AT FULL LOAD 4,000 5,000 5,400 6,000 7,000 7,000 8,000 10,000 12,000 MINIMUM COOLING AIRFLOW CFM (CV) 6,000 7,500 8,100 9,000 10,500 10,500 12,000 15,000 18,000 MAXIMUM AIRFLOW CFM 10,000 12,500 13,500 15,000 17,500 17,500 20,000 22,500 27,000 * Sizes 036,041, and 051 are 48AJ,AK,AW,AY only. CV VAV LEGEND — Constant Volume — Variable Air Volume NOTE: Variable air volume units will operate down to 70 cfm/ton in Cooling mode. Performance at 70 cfm/ton is limited to unloaded operation and may be also limited by edb (entering dry bulb) and ewb (entering wet bulb) conditions. 26 Table 40B — Air Quantity Limits (50AJ,AK,AW,AY,A2,A3,A4,A5) UNIT 50AJ,AW,A2,A3020 50AK,AY,A4,A5020 50AJ,AW,A2,A3025 50AK,AY,A4,A5025 50AJ,AW,A2,A4027 50AK,AY,A3,A5027 50AJ,AW,A2,A4030 50AK,AY,A3,A5030 50AJ,AW,A2,A4035 50AJ,AW036 50AK,AY,A3,A5035 50AK,AY036 50AJ,AW,A2,A4040 50AJ,AW041 50AK,AY,A3,A5040 50AK,AY041 50AJ,AW,A2,A4050 50AK,AY,A3,A5050 50AJ,AW051 50AJ,AW,A2,A4060 50AK,AY051 50AK,AY,A3,A5060 COOLING Min CFM 6,000 4,000 7,500 5,000 8,100 5,400 9,000 6,000 10,500 10,500 7,000 7,000 12,000 12,000 8,000 8,000 13,500 10,000 18,000 18,000 12,000 12,000 ELECTRIC HEAT Max CFM* 10,000 10,000 12,500 12,500 13,500 13,500 15,000 15,000 17,500 17,500 17,500 17,500 20,000 20,000 20,000 20,000 20,000 20,000 27,000 27,000 27,000 27,000 Min CFM Max CFM 6,000 15,000 10,500 20,000 15,000 27,000 *Operation at these levels may be limited by entering evaporator air wet bulb temperatures. be configured. See the Heating Control and Cooling Control sections on pages 50 and 37 for further description on these configurations. The following set points may be configured: CONTROLS QUICK START The following section will provide a quick user guide to setting up and configuring the A Series units with ComfortLink™ controls. See Basic Control Usage section on page 3 for information on operating the control. For wiring information, refer to unit wiring diagrams in the Major System Components section on page 101. OHSP Occupied Heat Setpoint OCSP Occupied Cool Setpoint UHSP Unoccupied Heat Setpoint UCSP Unoccupied Cool Setpoint GAP Heat-Cool Setpoint Gap 5. The degrees of demand from the space temperature set points are configured under the ConfigurationD.LV.T submenu. See the Heating Control and Cooling Control sections for further description on these configurations. The following set points may be configured: IMPORTANT: The ComfortLink controls provide the user with numerous configuration options such as set points, demand levels, reset, and many others. If the building owner or design engineer has not provided specific recommendations for these configuration settings, it is suggested that the installer do not make changes to the default factory settings. The factory-configured default values are appropriate for many applications. IMPORTANT: The unit is shipped with the unit control disabled. Enable the control by setting Local Machine Disable (Service TestSTOP) to No. Two-Stage Constant Volume Units with Mechanical Thermostat — To configure the unit, per- form the following: 1. The type of control is configured under Configuration UNITC.TYP. Set C.TYP to 4 (TSTAT 2 STG). 2. Remove jumpers from R-W2 and W2-W1 on TB4 in the control box. 3. See Economizer Options section on page 28 for additional economizer option configurations. 4. See Exhaust Options section on page 29 for additional exhaust option configurations. 6. 7. 8. 9. Two-Stage Constant Volume Units with Space Sensor — To configure the unit, perform the following: L.H.ON Demand Level Lo Heat On H.H.ON Demand Level Hi Heat On L.H.OF Demand Level Lo Heat Off L.C.ON Demand Level Lo Cool On H.C.ON Demand Level Hi Cool On L.C.OF Demand Level Lo Cool Off Under ConfigurationUNITCV.FN, set CV.FN to 1 for continuous fan or 0 for automatic fan. To program time schedules, set SCH.N=1 under ConfigurationCCNSC.OVSCH.N to configure the control to use local schedules. Under the TimeclockSCH.L submenu, enter the desired schedule. See Time Clock Configuration section on page 75 for further description of these configurations. Under the ConfigurationCCNSC.OV submenu, the following schedules and overrides should be configured: O.T.L. SPT.O T58.O 1. The type of control is configured under Configuration UNITC.TYP. Set C.TYP to 6 (SPT 2 STG). 2. Under ConfigurationUNITSENSSPT.S, enable the space sensor by setting SPT.S to ENBL (enable). 3. Install jumpers between R-W2 and W2-W1 on TB4 in the control box. 4. The space temperature set points are configured under the Setpoints menu. The heating and cooling set points may Override time limit SPT override enabled? T58 override enabled? 10. See Economizer Options section on page 28 for additional economizer option configurations. 11. See Exhaust Options section on page 29 for additional exhaust option configurations. 27 5. See the Exhaust Options section on page 29 for additional exhaust option configurations. Variable Air Volume Units Using Return Air Sensor or Space Temperature Sensor — To con- figure the unit, perform the following: 1. The type of control is configured under Configuration UNITC.TYP. Set C.TYP to 1 (VAV-RAT) for return air sensor. Set C.TYP to 2 (VAV-SPT) for space temperature sensor. NOTE: For VAV with a space sensor (VAV-SPT), under ConfigurationUNITSENSSPT.S, enable the space sensor by setting SPT.S to ENBL. 2. Install jumpers between R-W2 and W2-W1 on TB4 in the control box. 3. The space temperature set points and the supply air set points are configured under the Setpoints menu. The heating and cooling set points must be configured. See the Heating Control and Cooling Control sections for further description on these configurations. Configure the following set points: OHSP OCSP UHSP V.C.ON V.C.OF SASP Multi-Stage Constant Volume Units with Space Sensor — To configure the unit, perform the following: 1. Under ConfigurationUNITC.TYP, set C.TYP to 5 (SPT MULTI). 2. Install jumpers between R-W2 and W2-W1 on TB4 in the control box. 3. Under the Setpoints menu, the following configurations should be set: OHSP OCSP UHSP UCSP GAP SA.HI SA.LO Occupied Heat Setpoint Occupied Cool Setpoint Unoccupied Heat Setpoint VAV Occupied Cool On Delta VAV Occupied Cool Off Delta Supply Air Setpoint 4. The degrees of demand from the space temperature set points are configured under the ConfigurationD.LV.T submenu. See the Heating Control and Cooling Control sections for further description on these configurations. Configure the following set points: 4. To program time schedules, make sure SCH.N=1 under ConfigurationCCNSC.OVSCH.N to configure the control to use local schedules. 5. Under the TimeclockSCH.L submenu, enter the desired schedule. See Time Clock Configuration section on page 75 for further description of these configurations. 6. Under ConfigurationSPSP.SP, the supply duct Static Pressure Setpoint should be configured. SP.SP L.H.ON H.H.ON L.H.OF L.C.ON H.C.ON L.C.OF EDT Reset Configuration Reset Ratio (if RS.CF = 1 or 2) Reset Limit (if RS.CF = 1 or 2) EDT 4-20 mA Reset Input (if RS.CF = 3) NOTE: Configure either RTIO and LIMT or RES.S. All three are not used. 8. See the Economizer Options section on this page for additional economizer option configurations. 9. See the Exhaust Options section on page 29 for additional exhaust option configurations. Economizer Options — Under the Configuration ECON submenu, the following set points may be configured: EC.EN EC.MN EC.MX E.TRM E.SEL OA.E.C OA.EN OAT.L O.DEW ORH.S Multi-Stage Constant Volume Units with Mechanical Thermostat — To configure the unit, per- form the following: 1. Under ConfigurationUNITC.TYP, set C.TYP to 3 (TSTAT MULTI). 2. Remove jumpers from R-W2 and W2-W1 on TB4 in the control box. Connect thermostat to TB4. 3. Under the Setpoints menu, set the following configurations: SA.HI SA.LO Demand Level Lo Heat On Demand Level Hi Heat On Demand Level Lo Heat On Demand Level Lo Cool On Demand Level Hi Cool On Demand Level Lo Cool On 5. Under ConfigurationUNITSENSSPT.S, enable the space sensor by setting SPT.S to ENBL. 6. Under ConfigurationUNITCV.FN, set CV.FN to 1 for continuous fan or 0 for automatic fan. 7. To program time schedules, set SCH.N=1 under ConfigurationCCNSC.OVSCH.N to configure the control to use local schedules. 8. Under the TimeclockSCH.L submenu, enter the desired schedule. See Time Clock Configuration section on page 75 for further description of these configurations. 9. See the Economizer Options section below for additional economizer option configurations. 10. See the Exhaust Options section on page 29 for additional exhaust option configurations. Static Pressure Setpoint 7. If supply air temperature reset is desired, under the ConfigurationEDT.R submenu, the following set points should be configured: RS.CF RTIO LIMT RES.S Occupied Heat Setpoint Occupied Cool Setpoint Unoccupied Heat Setpoint Unoccupied Cool Setpoint Heat-Cool Setpoint Gap Supply Air Set Point Hi Supply Air Set Point Lo Supply Air Set Point Hi Supply Air Set Point Lo Economizer Enabled? Economizer Min.Position Economizer Maximum Position Economizer Trim for SumZ? Econ Changeover Select OA Enthalpy Change Over Select Outdoor Enthalpy Compare Value High OAT Lockout Temp OA Dew Point Temp Limit Outside Air RH Sensor ConfigurationECONEC.MN should always be set for the minimum damper position. 4. See the Economizer Options section on this page for additional economizer option configurations. 28 correct value for hours, in 24-hour (military) time. Press ENTER and hour value is saved and the minutes digits will start flashing. Use the same procedure to display and save the desired minutes value. Press ESCAPE. 4. Configure the unoccupied time for period 1 (UNC). Scroll down to UNC and press ENTER to go into Edit mode. The first two digits of the 00.00 will start flashing. Use the UP or DOWN key to display the correct value for hours, in 24-hour (military) time. Press ENTER and hour value is saved and the minutes digits will start flashing. Use the same procedure to display and save the desired minutes value. Press ESCAPE. 5. Scroll to DAYS and press ENTER. Scroll down to the MON point. This point indicates if schedule 1 applies to Monday. Use the ENTER command to go into Edit mode, and use the UP or DOWN key to change the display to YES or NO. Scroll down through the rest of the days and apply schedule 1 where desired. The schedule can also be applied to a holiday. Press ESCAPE. 6. The first schedule is now complete. If a second schedule is needed, such as for weekends or holidays, scroll down and repeat the entire procedure for period 2 (PER.2). If additional schedules are needed, repeat the process for as many as are needed. Eight schedules are provided. Indoor Air Quality (IAQ) Options DEMAND CONTROLLED VENTILATION — Under ConfigurationIAQDCV.C, the following configuration parameters should be set to establish the minimum and maximum points for outdoor air damper position during demand controlled ventilation (DCV): EC.MN Economizer Min.Position IAQ.M IAQ Demand Vent Min.Pos. ConfigurationIAQDCV.CIAQ.M is used to set the absolute minimum vent position (or maximum reset) under DCV. ConfigurationIAQDCV.CEC.MN is used to set the minimum damper position (or with no DCV reset). This is also referenced in the economizer section. Exhaust Options — The A Series units can be config- ured with constant volume 2-stage power exhaust or modulating power exhaust. The following exhaust options should be configured. ConfigurationBPBF.CF=1 (Two-Stage Exhaust Option) — For two-stage exhaust, under the Configuration BP submenu, configure the following: BP.P1 BP.P2 Power Exhaust On Setp.1 Power Exhaust On Setp.2 SERVICE TEST General — The units are equipped with a Service Test fea- ConfigurationBPBF.CF=2 (Modulating Power Exhaust Option) — For modulating exhaust, in the Configuration BP submenu, configure the following: BP.SP ture, which is intended to allow a service person to force the unit into different modes of operation to test them. To use this feature, enter the Service Test category on the local display and place the unit into the test mode by changing Service TestTEST from OFF to ON. The display will prompt for the password before allowing any change. The default password is 1111. Once the unit enters the Service Test mode, the unit will shut down all current modes. TEST — The TEST command turns the unit off (hard stop) and allows the unit to be put in a manual control mode. STOP — The STOP command completely disables the unit (all outputs turn off immediately). Once in this mode, nothing can override the unit to turn it on. The controller will ignore all inputs and commands. S.STP — Setting Soft Stop to YES turns the unit off in an orderly way, honoring any time guards currently in effect. FAN.F — By turning the FAN FORCE on, the supply fan is turned on and will operate as it normally would, controlling duct static pressure on VAV applications or just energizing the fan on CV applications. To remove the force, press ENTER and then press the UP and DOWN arrows simultaneously. F.4.CH — The 4-Inch Filter Change Mode variable is used to service the unit when 4-in. filters are used. When the filters need to be changed, set Service TestF.4.CH = YES. The unit will be placed in Service Test mode and the economizer will move to the 40% open position to facilitate removal of the 4-in. filters. After the filters have been changed, set Service TestF.4.CH = NO to return the unit to normal operation. The remaining categories: INDP, FANS, COOL, and HEAT are sub-modes with separate items and functions. See Table 41. Service Test Mode Logic — Operation in the Service Test mode is sub-mode specific except for the Independent submode. Leaving the sub-mode while a test is being performed and attempting to start a different test in the new sub-mode will cause the previous test to terminate. When this happens, the new request will be delayed for 5 seconds. For example, if compressors were turned on under the COOL sub-mode, any attempt to turn on heating stages within the HEAT sub-mode would immediately turn off the compressors and, 5 seconds later, the controller would honor the requested heat stages. Building Pressure Setp. Programming Operating Schedules — The ComfortLink™ controls will accommodate up to eight different schedules (Periods 1 through 8), and each schedule is assigned to the desired days of the week. Each schedule includes an occupied on and off time. As an example, to set an occupied schedule for 8 AM to 5 PM for Monday through Friday, the user would set days Monday through Friday to ON for Period 1. Then the user would configure the Period 1 Occupied From point to 08:00 and the Period 1 Occupied To point to 17:00. To create a different weekend schedule, the user would use Period 2 and set days Saturday and Sunday to ON with the desired Occupied On and Off times. To create a schedule, perform the following procedure: NOTE: By default, the time schedule periods are programmed for 24 hours of occupied operation. 1. Scroll to the Configuration mode, and select CCN CONFIGURATION (CCN). Scroll down to the Schedule Number (ConfigurationCCNSC.OVSCH.N). If password protection has been enabled, the user will be prompted to enter the password before any new data is accepted. SCH.N has a range of 0 to 99. The default value is 1. A value of 0 is always occupied, and the unit will control to its occupied set points. A value of 1 means the unit will follow a local schedule, and a value of 65 to 99 means it will follow a CCN schedule. Schedules 2 to 64 are not used as the control only supports one internal/local schedule. If one of the 2 to 64 schedules is configured, then the control will force the number back to 1. Make sure the value is set to 1 to use a local schedule. 2. Enter the Time Clock mode. Scroll down to the LOCAL TIME SCHEDULE (SCH.L) sub-mode, and press ENTER. Period 1 (PER.1) will be displayed. Press ENTER to configure Period 1. 3. Configure the beginning of the occupied time period for Period 1 (OCC). Scroll down to OCC and press ENTER to go into Edit mode. The first two digits of the 00.00 will start flashing. Use the UP or DOWN key to display the 29 individually. After starting each compressor, the control will check the suction pressure after 5 seconds of run time. If the control does not see a sufficient decrease in suction pressure after 5 seconds, mechanical cooling will be shut down, and an alarm will be generated (A140). This alarm requires a manual reset. If this alarm occurs, do not attempt a restart of the compressor and do not attempt to start any other compressors until the wiring to the unit has been corrected. However, it is important to note that the user can leave a Service Test mode to view any of the local display modes and the control will remain in the Service Test mode. Independent Outputs — The INDP sub-mode items can be turned on and off regardless of the other category states. For example, the alarm relay can be forced on in the INDP sub-mode and will remain on if compressor relays are requested in the COOL sub-mode. Heating in Service Test Mode — If unit has a thermostat connected (C.TYP = 3 or 4), install the RED jumper wires between TB4, terminals R (1), W2 (3) and W1 (4). Terminal block TB4 is located in the unit control box. Remember to disconnect these jumpers when Test Mode is completed. The Heat Test Mode sub-mode will offer automatic fan start-up if the unit is not a gas heat unit. On gas heat units, the IGC feedback from the gas control units will bring the fan on as required. Within this sub-mode, the user has control of heat relays 1 to 6. The user can also turn on the requested heat stage. NOTE: When service test has been completed, if unit has a thermostat connected (C.TYP = 3 or 4), remove the RED jumper wires at TB4, terminals R (1), W2 (3) and W1 (4). Terminal block TB4 is located in the unit control box. Store these jumpers in the unit control box for future use. Fans in Service Test Mode — Upon entering the FANS sub-mode, the user will be able to turn the supply fan on and off, set the supply fan VFD speed, and turn the condenser fans on and off. Cooling in Service Test Mode — The COOL submode offers different cooling service tests. The user has manual relay control of individual compressors. If the user energizes mechanical cooling, the supply fan and the outdoor fans will be started automatically. During mechanical cooling, the unit will protect itself. Compressor diagnostics are active, monitoring for high discharge pressure, low suction pressure, etc. The user can also turn the hot gas bypass valve on and off. NOTE: It is crucial that proper compressor rotation be verified during the service test. Each compressor must be tested Table 41 — Service Test ITEM TEST STOP S.STP FAN.F F.4.CH INDP ECON E.PWR E.CAL E.VFD PE.A PE.B PE.C H.I.R ALRM FANS S.FAN S.VFD CD.F.A CD.F.B COOL A1 A2 MLV B1 B2 HEAT HT.ST HT.1 HT.2 HT.3 HT.4 HT.5 HT.6 EXPANSION Service Test Mode Local Machine Disable Soft Stop Request Supply Fan Request 4 in. Filter Change Mode TEST INDEPENDENT OUTPUTS Economizer Act.Cmd.Pos. Economizer Power Test Calibrate the Economizer? Exhaust Fan VFD Speed Power Exhaust Relay A Power Exhaust Relay B Power Exhaust Relay C Heat Interlock Relay Remote Alarm/Aux Relay TEST FANS Supply Fan Relay Supply Fan VFD Speed Condenser Fan Circuit A Condenser Fan Circuit B TEST COOLING Compressor A1 Relay Compressor A2 Relay Min. Load Valve (HGBP) Compressor B1 Relay Compressor B2 Relay TEST HEATING Requested Heat Stage Heat Relay 1 Heat Relay 2 Relay 3 W1 Gas Valve 2 Relay 4 W2 Gas Valve 2 Relay 5 W1 Gas Valve 3 Relay 6 W2 Gas Valve 3 RANGE ON/OFF YES/NO YES/NO YES/NO YES/NO 0-100 UNITS % ON/OFF ON/OFF ON/OFF 0-100 ON/OFF ON/OFF % POINT MAN_CTRL UNITSTOP SOFTSTOP SFANFORC FILT4CHG ECONCTST ECONPTST ECON_CAL EFAN_VFD PE_A_TST PE_B_TST PE_C_TST HIR_TST ALRM_TST SFAN_TST SGVFDTST CNDA_TST CNDB_TST ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF CMPA1TST CMPA2TST MLV_TST CMPB1TST CMPB2TST 0-MAX ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF HTST_TST HS1_TST HS2_TST HS3_TST HS4_TST HS5_TST HS6_TST 30 WRITE STATUS config forcible forcible A 4 to 20 mA input that can reduce or limit capacity linearly to a set point percentage. In either case, it will be necessary to install a controls expansion module (CEM). DEMAND LIMIT DISCRETE INPUTS — First, set DM.L.S in ConfigurationDMD.L to 1 (2 switches). When InputsGEN.IDL.S1 (Demand Switch no. 1) is OFF, the control will not set any limit to the capacity, and when ON, the control sets a capacity limit to the ConfigurationDMD.LD.L.S1 set point. Likewise, when InputsGEN.IDL.S2 (Demand Switch no. 2) is OFF, the control will not set any limit to the capacity, and when ON, the control sets a capacity limit to the ConfigurationDMD.LD.L.S2 set point. If both switches are ON, InputsGEN.IDL.S2 is used as the limiter of capacity. Under ConfigurationSW.LG, set the logic state appropriately for the action desired. Set the DL1.L and DL2.L configurations. They can be set normally open or normally closed. For example, if DL1.L is set to OPEN, the user will need to close the switch to cause the control to limit capacity to the demand limit 1 set point. Likewise, if DL1.L is set to CLSE (closed), the user will need to open the switch to cause the control to limit capacity to the demand limit 1 set point. DEMAND LIMIT 4 TO 20 mA INPUT — Under ConfigurationDMD.L, set configuration DM.L.S to 2 (2 = 4 to 20 mA control). Under the same menu, set D.L.20 to a value from 0 to 100% to set the demand limit range. For example, with D.L.20 set to 50, a 4 mA signal will result in no limit to the capacity and 20 mA signal will result in a 50% reduction in capacity. THIRD PARTY CONTROL Thermostat — The method of control would be through the thermostat inputs: Y1 = first stage cooling Y1 and Y2 = first and second stage cooling W1 = first stage heating W1 and W2 = first and second stage heating G = supply fan Alarm Output — The alarm output TB4-7 and 8, will provide relay closure whenever the unit is under an alert or alarm condition. Remote Switch — The remote switch may be configured for three different functions. Under ConfigurationUNIT, set RM.CF to one of the following: 0 = no remote switch 1 = occupied/unoccupied switch 2 = start/stop switch 3 = occupancy override switch With RM.CF set to 1, no time schedules are followed and the unit follows the remote switch only in determining the state of occupancy. With RM.CF set to 2, the remote switch can be used to shut down and disable the unit, while still honoring time guards on compressors. Time schedules, internal or external, may be run simultaneously with this configuration. With RM.CF set to 3, the remote input may override an unoccupied state and force the control to go into occupied mode. As with the start/stop configuration, an internal or external time schedule may continue to control occupancy when the switch is not in effect. Under ConfigurationSW.LGRMI.L, the remote occupancy switch can be set to either a normally open or normally closed switch input. Normal is defined as either unoccupied, start or “not currently overridden,” respective to the RM.CF configuration. Demand Controlled Ventilation Control — There are multiple methods for externally controlling the economizer damper. IAQ DISCRETE INPUT CONFIGURATION — The IAQ discrete input configuration requires a CEM module (optional) to be installed and an interface to a switch input at TB5-13 and 14. The state of the input on the display can be found at InputsAIR.QIAQ.I. Before configuring the switch functionality, first determine how the switch will be read. A closed switch can indicate either a low IAQ condition or a high IAQ condition. This is set at ConfigurationSW.LG and IAQ.L. The user can set what a low reading would mean based on the type of switch being used. Setting IAQ.L to OPEN means that when the switch is open the input will read LOW. When the switch is closed, the input will read HIGH. Setting IAQ.L to CLSE (closed) means that when the switch is closed the input will read LOW, and therefore, when the switch is open the switch will read HIGH. There are two possible configurations for the IAQ discrete input. Select item ConfigurationIAQAQ.CFIQ.I.C and configure for either 1 (IAQ Discrete) or 2 (IAQ Discrete Override). IQ.I.C = 1 (IAQ Discrete) — If the user sets IQ.I.C to 1 (IAQ Discrete), and the switch logic (ConfigurationSW.LG IAQ.L) is set to OPEN, then an open switch reads low and a closed switch reads high. If the switch is open, the economizer will be commanded to the IAQ Demand Vent Minimum Position. These settings may be adjusted and are located at ConfigurationIAQDCV.CIAQ.M. If the switch is closed, the IAQ reading will be high and the economizer will be commanded to the Economizer Minimum Position. This setting may be adjusted and is located at ConfigurationIAQDCV.CEC.MN. VFD Control — On VFD equipped supply fans, supply duct static pressure control may be left under unit control or be externally controlled. To control a VFD externally with a 4 to 20 mA signal, set SP.RS to 4, under the ConfigurationSP menu. This will set the reset to VFD control. When SP.RS = 4, the static pressure reset function acts to provide direct VFD speed control where 4 mA = 0% speed and 20 mA = 100% (SP.MN and SP.MX will override). Note that SP.CF must be set to 1 (VFD Control) prior to configuring SP.RS = 4. Failure to do so could result in damage to ductwork due to overpressurization. In effect, this represents a speed control signal “pass through” under normal operating circumstances. The ComfortLink controller overrides the third party signal for critical operation situations, most notably smoke and fire control. Wire the input to the controls expansion module (CEM) using TB-11 and 12. An optional CEM board is required. See Appendix C and the VFD literature supplied with the unit for VFD configurations and field wiring connections to the VFD. Supply Air Reset — With the installation of the CEM, the ComfortLink controller is capable of accepting a 4 to 20 mA signal, to reset the supply-air temperature up to a maximum of 20 F. See VFD Control section above. Demand Limit Control — The term “demand limit control” refers to the restriction of the machine’s mechanical cooling capacity to control the amount of power that a machine may use. Demand limiting using mechanical control is possible via two means: Two discrete inputs tied to demand limit set point percentages. OR 31 The 4 to 20 mA signal from the sensor wired to TB5-6 and 7 is scaled to an equivalent indoor CO2 (IAQ) by the parameters IQ.R.L and IQ.R.H located under the Configuration IAQAQ.S.R menu. The parameters are defined such that 4 mA = IQ.R.L and 20 mA = IQ.R.H. When the differential air quality DAQ (IAQ – OAQ.U) exceeds the DAQ.H set point (ConfigurationIAQAQ.SP menu) and the supply fan is on, the economizer minimum vent position (Configuration IAQDCV.CEC.MN) is overridden and the damper is moved to the IQ.P.O configuration. When the DAQ falls below the DAQ.L set point (ConfigurationIAQAQ.SP menu), the economizer damper is moved back to the minimum vent position (EC.MN). NOTE: Configuration OAQ.U is used in the calculation of the trip point for override and can be found under Configuration IAQAQ.SP. IQ.A.C = 3 (4 to 20 mA Damper Control) — This configuration will provide full 4 to 20 mA remotely controlled analog input for economizer minimum damper position. The 4 to 20 mA signal is connected to terminals TB5-6 and 7. The input is processed as 4 mA = 0% and 20 mA = 100%, thereby giving complete range control of the effective minimum position. The economizer sequences can be disabled by setting ConfigurationECONE.SEL to 0. Complete control of the economizer damper position is then possible by using a 4 to 20 mA economizer minimum position control or a 0 to 10 kilo-ohm 0 to 100% economizer minimum position control via configuration decisions at ConfigurationIAQAQ.CF IQ.A.C. IQ.A.C = 4 (10 Kilo-ohm Potentiometer Damper Control) — This configuration will provide input for a 10 kilo-ohm linear potentiometer that acts as a remotely controlled analog input for economizer minimum damper position. The input is processed as 0 ohms = 0% and 10,000 ohms = 100%, thereby giving complete range control of the effective minimum position. IQ.I.C = 2 (IAQ Discrete Override) — If the user sets IQ.I.C to 2 (IAQ Discrete Override), and ConfigurationSW.LG IAQ.L is set to OPEN, then an open switch reads low and a closed switch reads high. If the switch reads low, no action will be taken. If the switch reads high, the economizer will immediately be commanded to the IAQ Economizer Override Position. This can be set from 0 to 100% and can be found at ConfigurationIAQAQ.SP IQ.O.P. FAN CONTROL FOR THE IAQ DISCRETE INPUT — Under ConfigurationIAQAQ.CF, the IQ.I.F (IAQ Discrete Input Fan Configuration) must also be set. There are three configurations for IQ.I.F. Select the configuration which will be used for fan operation. This configuration allows the user to decide (if the supply fan is not already running), whether the IAQ discrete switch will start the fan, and in which state of occupancy the fan will start. IQ.I.F = 0 Minimum Position Override Switch input will not start fan IQ.I.F = 1 Minimum Position Override Switch input will start fan in occupied mode only IQ.I.F = 2 Minimum Position Override Switch input will start fan in both occupied and unoccupied modes IAQ ANALOG INPUT CONFIGURATION — This input is an analog input located on the main base board (MBB). There are 4 different functions for this input. The location of this configuration is at ConfigurationIAQAQ.CFIQ.A.C. The functions possible for IQ.A.C are: • 0 = no IAQ analog input • 1 = IAQ analog input • 2 = IAQ analog input used to override to a set position • 3 = 4 to 20 mA 0 to 100% economizer minimum position control • 4 = 0 to 10 kilo-ohms 0 to 100% economizer minimum position control Options 2, 3, and 4 are dedicated for third party control. IQ.A.C = 2 (IAQ Analog Input Used to Override) — Under ConfigurationIAQAQ.SP, set IQ.O.P (IAQ Economizer Override Position). The IQ.O.P configuration is adjustable from 0 to 100%. These configurations are also used in conjunction with ConfigurationIAQAQ.CFIQ.A.F (IAQ 4 to 20 mA Fan Configuration). There are three configurations for IQ.A.F and they follow the same logic as for the discrete input. This configuration allows the user to decide (if the supply fan is not already running), if the IAQ Analog Minimum Position Override input will start the fan, and in which state of occupancy the fan will start. IQ.A.F = 0 IAQ analog sensor input cannot start the supply fan IQ.A.F = 1 IAQ analog sensor input can start the supply fan in occupied mode only IQ.A.F = 2 IAQ analog sensor input can start the supply fan in both occupied and unoccupied modes CONTROLS OPERATION Modes — The ComfortLink™ controls operate under a hierarchy of command structure as defined by three essential elements: the System mode, the HVAC mode and the Control mode. The System mode is the top level mode that defines three essential states for the control system: OFF, RUN and TEST. The HVAC mode is the functional level underneath the System mode which further defines the operation of the control. The mode selection process is shown in Appendix D. The Control mode is essentially the control type of the unit (ConfigurationUNITC.TYP). This defines from where the control looks to establish a cooling or heating mode and whether 2 stages or multiple stages of cooling capacity operation are controlled. Furthermore, there are a number of modes which operate concurrently when the unit is running. The operating modes of the control are located at the local displays under Operating Modes. See Table 42. Currently Occupied (OCC) — This variable displays the current occupied state of the unit. Timed Override in Effect (T.OVR) — This variable displays if the state of occupancy is currently occupied due to an override. DCV Resetting Minimum Position (DCV) — This variable displays if the economizer position has been lowered from its maximum vent position. If IQ.A.F is configured to request the supply fan, then configurations D.F.ON and D.F.OF need to be set. These configuration settings are located under Configuration IAQAQ.SP and configure the fan override operation based on the differential air quality (DAQ). If DAQ rises above D.F.ON, the control will request the fan on until DAQ falls below D.F.OF. NOTE: If D.F.ON is configured below DAQ.H, the unit is in occupied mode, and the fan was off, then DAQ rose above D.F.ON and the fan came on, the economizer will go to the economizer minimum position (EC.MN). 32 (“Internal Failure”) System Mode Test — When the system mode is Test, the control is limited to the Test mode and is controllable via the local displays (scrolling marquee and Navigator™ display) or through the factory service test control. The System Test modes are Factory Test Enabled and Service Test Enabled. See the Service Test Mode section for details on test control in this mode. 1. Factory Test mode (“Factory test enabled”) 2. Service Test mode (“Service test enabled”) System Mode Run — When the system mode is Run, the software application in the control is free to run the HVAC control routines by which cooling, heating, IAQ, etc., is possible. There are two possible text displays for this mode, one is normal run mode and the other occurs if one of the following fire-smoke modes is present: smoke purge, pressurization or evacuation. 1. Normal run time state (“Unit Operation Enabled”) 2. Fire-Smoke control mode (“Fire-Smoke Control”) HVAC MODES (Operating ModeHVAC) — The system mode must be selected before the unit controls can select the HVAC mode of the rooftop unit. The selection of an HVAC mode is based on a hierarchal decision making process. Certain overrides may interfere with this process and the normal temperature/humidity control operation of the unit. The decision making process that determines the HVAC mode is shown in Fig. 4 and Appendix D. Each HVAC Mode is described below. The HVAC mode number is shown in parenthesis after the mode. HVAC Mode — STARTING UP (0) — The unit is transitioning from the OFF mode to a different mode. HVAC Mode — DISABLED (1) — The unit is shut down due to a software command disable through the scrolling marquee, a CCN emergency stop command, a service test end, or a control-type change delay. HVAC Mode — SHUTTING DOWN (2) — The unit is transitioning from a mode to the OFF mode. HVAC Mode — SOFTSTOP REQUEST (3) — The unit is off due to a soft stop request from the control. HVAC Mode — REM SW.DISABLE (4) — The unit is off due to the remote switch. HVAC Mode — FAN STATUS FAIL (5) — The unit is off due to failure of the fan status switch. HVAC Mode — STATIC PRESSURE FAIL (6) — The unit is off due to failure of the static pressure sensor. HVAC Mode — COMP.STUCK ON (7) — The unit is shut down because there is an indication that a compressor is running even though it has been commanded off. HVAC Mode — OFF (8) — The unit is off and no operating modes are active. HVAC Mode — TEST (9) — The unit is in the self test mode which is entered through the Service Test menu. HVAC Mode — TEMPERING VENT (10) — The economizer is at minimum vent position but the supply-air temperature has dropped below the tempering vent set point. Staged gas heat is used to temper the ventilation air. HVAC Mode — TEMPERING LOCOOL (11) — The economizer is at minimum vent position but the combination of the outside-air temperature and the economizer position has dropped the supply-air temperature below the tempering cool set point. Staged gas heat is used to temper the ventilation air. Table 42 — Operating Modes Display Table ITEM SYS.M HVAC CTRL MODE OCC T.OVR DCV SA.R DMD.L T.C.ST IAQ.P LINK LOCK H.NUM EXPANSION RANGE ascii string ascii string ascii string MODES CONTROLLING UNIT Currently Occupied ON/OFF Timed Override in Effect ON/OFF DCV Resetting Min Pos ON/OFF Supply Air Reset ON/OFF Demand Limit in Effect ON/OFF Temp.Compensated Start ON/OFF IAQ Pre-Occ Purge Active ON/OFF Linkage Active — CCN ON/OFF Mech.Cooling Locked Out ON/OFF HVAC Mode Numerical Form number CCN POINT n/a n/a n/a MODEOCCP MODETOVR MODEADCV MODESARS MODEDMLT MODETCST MODEIQPG MODELINK MODELOCK MODEHVAC Supply Air Reset (SA.R) — This variable displays if the supply air reset is currently active. This applies to cooling only. Demand Limit in Effect (DMD.L) — This variable displays if the mechanical cooling capacity is currently being limited or reduced by an outside third party. Temperature Compensated Start (T.C.ST) — This variable displays if Heating or Cooling has been initiated before the occupied period to pre-condition the space. IAQ Pre-Occupancy Purge Active (IAQ.P) — This variable displays if the economizer is open and the fan is on to preventilate the building before occupancy. Linkage Active CCN (LINK) — This variable displays if a linkage master in a zoning system has established “linkage” with this air source (rooftop). Mechanical Cooling Locked Out (LOCK) — This variable displays if mechanical cooling is currently being locked due to low outside air temperature. HVAC Mode Numerical Form (H.NUM) — This is a numerical representation of the HVAC modes which may be read via a point read. SYSTEM MODES (Operating ModesSYS.M) System Mode Off — When the system mode is OFF, all outputs are to be shut down and no machine control is possible. The following list displays the text assigned to the System Mode when in the OFF mode and the conditions that may cause this mode are checked in the following hierarchal order: 1. Wake up timer on a power reset. (“Initializing System ...”) 2. System in the process of shutting down compressors and waiting for timeguards to expire. (“Shutting Down ...”) 3. Factory shut down (internal factory control level — SHUTDOWN). (“Factory Shut Down”) 4. Unit stop (software application level variable that acts as a hard shut down — Service TestSTOP). (“Local Machine Stop”) 5. Fire shut down (traumatic fire shutdown condition based on the Fire Shutdown Input — InputsFIREFSD). (“Fire-Shutdown Mode”) 6. Emergency stop, which is forced over the CCN through the Emergency Stop Variable (EMSTOP). (“CCN Emergency Stop”) 7. Startup delay. (“Startup delay = 0-900 secs”) 8. Service test ending transition timer. (“Service Test Ending”) 9. Unexplained internal software failure. 33 System Mode = OFF? No FireSmoke Control System Mode Yes Inputs -> FIRE -> FSD in alarm? No Unit not in factory test AND fire-smoke control mode is alarming? No Yes HVAC Mode = OFF (Disabled) Inputs -> FIRE -> PRES in alarm? Yes No Inputs -> FIRE -> EVAC in alarm? Yes HVAC Mode = OFF (Fire Shutdown) No Yes HVAC Mode = OFF (Pressurization) HVAC Mode = OFF (Evacuation) HVAC Mode = OFF (Purge) Exceptions Config->UNIT-> C.TYP changed while unit running? No System Mode = TEST? No Yes Yes 15-second delay Config->UNIT-> RM.CF =2 AND Inputs->GEN.I-> REMT = ON Service Test -> S.STP = YES? Yes Yes HVAC Mode = SoftStop Request HVAC Mode = TEST No HVAC Mode = OFF (Rem. Sw. Disable) HVAC Mode = OFF (Disabled) Config->SP-> SP.CF = 1 OR 2 and static pressure sensor has failed Yes HVAC Mode = OFF (Static Pres. Fail) Unit control free to select normal heating/cooling HVAC mode No Config->UNIT-> SFS.M=1 OR 2 AND Config->UNIT-> SFS.S=YES? and supply fan has failed No Unit just waking up from power reset? Yes No Yes HVAC Mode = OFF (Fan Status Fail) Unit shutting down? No Yes HVAC Mode = OFF (Starting Up) HVAC Mode = Shutting Down HVAC Mode = OFF HVAC Mode = Vent HVAC Mode = Tempering Vent HVAC Mode = Low Cool Unit control free to choose HVAC Mode HVAC Mode = Tempering LoCool HVAC Mode = High Cool HVAC Mode = Tempering HiCool HVAC Mode = Low Heat HVAC Mode = Compressor Stuck On HVAC Mode = High Heat HVAC Mode = Unocc. Free Cool Fig. 4 — Mode Selection 34 A48-8268 accurate return-air temperature before the return-air temperature is allowed to call out any mode. • C.TYP = 3 (TSTAT-MULTI) This configuration will force the control to monitor the thermostat inputs to make a determination of mode. Unlike traditional 2-stage thermostat control, the unit is allowed to use multiple stages of cooling control and perform VAVtype operation. The control will be able to call out a LOW COOL or a HIGH COOL mode and maintain a low or high cool supply air set point. • C.TYP = 4 (TSTAT-2 STG) This configuration will force the control to monitor the thermostat inputs to make a determination of mode and allow only 2 stages of control for both heating and cooling. • C.TYP = 5 (SPT-MULTI) This configuration will force the control to monitor a space temperature sensor to make a determination of mode. Unlike traditional 2-stage space temperature control, the unit is allowed to use multiple stages of cooling control and perform VAV-type operation. The control will be able to call out a LOW COOL or a HIGH COOL mode and maintain a low or high cool supply air set point. • C.TYP = 6 (SPT-2 STG) This configuration will force the control to monitor the space temperature sensor to make a determination of mode and allow 2 stages of control for both heating and cooling. FAN MODE (CV.FN) — The Fan Mode configuration can be used for machine control types (Configuration UNITC.TYP) 3, 4, 5, and 6. The Fan Mode variable establishes the operating sequence for the supply fan during occupied periods. When set to 1 (Continuous), the fan will operate continuously during occupied periods. When set to 0 (Automatic), the fan will run only during a heating or cooling mode. REMOTE SWITCH CONFIG (RM.CF) — The remote switch input is connected to TB6 terminals 1 and 3. This switch can be used for several remote control functions. Please refer to the Remote Control Switch Input section for details on its use and operation. CEM MODEL INSTALLED (CEM) — This configuration instructs the control to communicate with the controls expansion module (CEM) over the Local Equipment Network (LEN) when set to Yes. When the unit is configured for certain sensors and configurations, this option will be set to Yes automatically. The sensors and configurations that automatically turn on this board are: ConfigurationUNITSFS.M = 1 (Supply Fan Status Switch Monitoring) ConfigurationEDT.RRES.S = Enable (4 to 20 mA Supply Air Reset Sensor Enable) ConfigurationDMD.LDM.L.S = 1 (2 SWITCHES) (Demand Limiting using 2 discrete switches) ConfigurationDMD.LDM.L.S = 2 (4-20 MA CTRL) (Demand Limiting using a 4 to 20 mA sensor) ConfigurationIAQAQ.CFIQ.I.C = 1 (IAQ DISCRETE) (IAQ discrete switch control) ConfigurationIAQAQ.CFIQ.I.C = 2 (IAQ DISC.OVR) (IAQ discrete switch “override” control) ConfigurationIAQAQ.CFOQ.A.C = 1 (OAQ SENSDAQ) (Outdoor Air Quality Sensor) ConfigurationIAQAQ.CFOQ.A.C = 2 (4-20 NO DAQ) (4 to 20 mA sensor, no DAQ) Temperature Compensated Start Cooling Factor (TCS.C) — This factor is used in the equation of the Temperature Compensated Start Time Bias for cooling. Refer to the Temperature HVAC Mode — TEMPERING HICOOL (12) — The economizer is at minimum vent position but the combination of the outside-air temperature and the economizer position has dropped the supply-air temperature below the tempering cool set point. Staged gas heat is used to temper the ventilation air. HVAC Mode — VENT (13) — This is a normal operation mode where no heating or cooling is required and outside air is being delivered to the space to control IAQ levels. HVAC Mode — LOW COOL (14) — This is a normal cooling mode where a low cooling demand is required. HVAC Mode — HIGH COOL (15) — This is a normal cooling mode where a high cooling demand is required. HVAC Mode — LOW HEAT (16) — The unit will be in low heating demand mode using either gas or electric heat. HVAC Mode — HIGH HEAT (17) — The unit will be in high heating demand mode using either gas or electric heat. HVAC Mode — UNOCC. FREE COOL (18) — In this mode the unit will operate in cooling but will be using the economizer for free cooling. Entering this mode will depend on the status of the outside air. The unit can be configured for outside air changeover, differential dry bulb changeover, outside air enthalpy changeover, differential enthalpy changeover, or a custom arrangement of enthalpy/dewpoint and dry bulb. See the Economizer section for further details. HVAC Mode — FIRE SHUT DOWN (19) — The unit has been stopped due to a fire shutdown input (FSD) or two or more of the fire control modes, purge, evacuation, or pressurization have been requested simultaneously. HVAC Mode — PRESSURIZATION (20) — The unit is in the special fire pressurization mode where the supply fan is on, the economizer damper is open and the power exhaust fans are off. This mode is started by the Fire Pressurization (PRES) input which can be found in the INPUTFIRE sub-menu. HVAC Mode — EVACUATION (21) — The unit is in the special Fire Evacuation mode where the supply fan is off, the economizer damper is closed and the power exhaust fans are on. This mode is started by the Fire Evacuation (EVAC) input which can be found in the INPUTFIRE sub-menu. HVAC Mode — SMOKE PURGE (22) — The unit is in the special Fire Purge mode where the supply fan is on, the economizer damper is open and the power exhaust fans are on. This mode is started by the Fire Evacuation (PURG) input which can be found in the INPUTFIRE sub-menu. HVAC Mode — DEHUMIDIFICATION (23) — The unit is operating in Dehumidification mode. HVAC Mode — REHEAT (24) — The unit is operating in reheat mode. Unit Configuration Submenu — The UNIT sub- menu under the Configuration mode of the local display contains general unit configuration items. The sub-menu which contains these configurations is located at the local display under ConfigurationUNIT. See Table 43. Machine Control Type (C.TYP) — This configuration defines the control type and control source responsible for selecting a cooling, heating, or vent mode and in determining the method by which compressors are staged. The control types are: • C.TYP = 1 (VAV-RAT) and C.TYP = 2 (VAV-SPT) Both of these configurations refer to standard VAV operation. If the control is occupied, the supply fan is run continuously and return-air temperature will be used in the determination of the selection of a cooling mode. VAV-SPT differs from VAV-RAT only in that during the unoccupied period, space temperature will be used instead of return-air temperature to start the fan for 10 minutes to establish an 35 Suction Pressure Transducer Type (SP.XR) — This configuration specifies the type of suction pressure transducer that is being used. Set SP.XR to 0 for support of a pressure transducer with a range of 0 to 135 psig. Set SP.XR to 1 for support of a pressure transducer with a range of 0 to 200 psig. NOTE: The 48/50A2,A3,A4,A5 units do not require a change to the SP.XR factory default setting. Refrigerant Type (RFG.T) — This configuration specifies the type of refrigerant used in the unit. Configuration RFG.T is set to 0 if the refrigerant used is R-22. Configuration RFG.T is set to 1 if the refrigerant used is R-410A. Do not change this setting. Condenser Type (CND.T) — This configuration specifies the type of condenser installed in the unit. Configuration CND.T is set to 0 if the condenser is a round tube, plate fin coil (RTPF). Configuration CND.T is set to 1 if the condenser is a microchannel heat exchanger coil (MCHX). MAT Calc Config (MAT.S) — This configuration gives the user three options in the processing of the mixed-air temperature (MAT) calculation: • MAT.S = 0 There will be no MAT calculation. • MAT.S = 1 The control will attempt to learn MAT over time. Any time the system is in a vent mode and the economizer stays at a particular position for long enough, MAT is set to equal EDT. Using this, the control has an internal table whereby it can more closely determine the true MAT value. • MAT.S = 2 The control will not attempt to learn MAT over time. To calculate MAT linearly, the user should reset the MAT table entries by setting MAT.R to YES. Then set MAT.S = 2. The control will calculate MAT based on the position of the economizer, outside-air temperature, and return-air temperature. To freeze the MAT table entries, let the unit run with MAT.S = 1. Once sufficient data has been collected, change MAT.S = 2. Do not reset the MAT table. Compensated Start section for more information. A setting of 0 minutes indicates Temperature Compensated Start in Cooling is not permitted. Temperature Compensated Start Heating Factor (TCS.H) — This factor is used in the equation of the Temperature Compensated Start Time Bias for heating. Refer to the Temperature Compensated Start section for more information. A setting of 0 minutes indicates Temperature Compensated Start in Heating is not permitted. Fan Fail Shuts Downs Unit (SFS.S) — This configuration will determine whether the unit should shut down on a supply fan status fail or simply alert the condition and continue to run. If set to YES, then the control will shut down the unit and send out an alarm if supply fan status monitoring fails. If set to NO, the control will not shut down the unit if supply fan status monitoring fails but the control will send out an alert. Fan Status Monitoring (SFS.M) — This configuration selects the type of fan status monitoring to be performed. 0 - NONE — No switch or monitoring 1 - SWITCH — Use of the fan status switch 2 - SP RISE — Monitoring of the supply duct pressure. VAV Unoccupied Fan Retry Time (VAV.S) — Machine control types 1 and 2 (VAV-RAT,VAV-SPT) monitor the return-air temperature during unoccupied periods to determine if there is a valid demand for heating or cooling before initiating an unoccupied heating or cooling mode. If the routine runs but concludes a valid demand condition does not exist, then the process is not permitted for the period of time defined by this configuration. Reducing this value allows a more frequent resampling process. Setting this value to zero will prevent any sampling sequence. Unit Size (SIZE) — There are several unit sizes (tons) for the A Series control. Make sure this configuration matches the size called out by the model number of the unit. This is important as the cooling stage tables are directly determined based on this configuration. Discharge Pressure Transducers (DP.XR) — This configuration configures the unit for use with discharge pressure transducers. The 48/50A2,A3,A4,A5 units will be automatically configured for discharge pressure transducers and DP.XR should be set to Yes. Table 43 — Unit Configuration ITEM UNIT C.TYP CV.FN RM.CF CEM TCS.C TCS.H SFS.S SFS.M VAV.S SIZE DP.XR SP.XR RFG.T CND.T MAT.S MAT.R MAT.D ALTI DLAY STAT AUX.R SENS SPT.S SP.O.S SP.O.R RRH.S FLT.S EXPANSION UNIT CONFIGURATION Machine Control Type Fan Mode (0=Auto, 1=Cont) Remote Switch Config CEM Module Installed Temp.Cmp.Strt.Cool Factr Temp.Cmp.Strt.Heat Factr Fan Fail Shuts Down Unit Fan Stat Monitoring Type VAV Unocc.Fan Retry Time Unit Size (20-60) Discharge Press. Transducers Suct. Pres. Trans. Type REFRIG: 0=R22, 1=R410A CND HX TYP: 0=RTPF, 1=MCHX MAT Calc Config Reset MAT Table Entries? MAT Outside Air Default Altitude……..in feet: Startup Delay Time TSTAT-Both Heat and Cool Auxiliary Relay Config INPUT SENSOR CONFIG Space Temp Sensor Space Temp Offset Sensor Space Temp Offset Range Return Air RH Sensor Filter Stat.Sw.Enabled ? RANGE 1-6 0-1 0-3 Yes/No 0 - 60 0 - 60 Yes/No 0-2 0 - 720 20 - 60 Yes/No 0-1 0-1 0-1 0-2 Yes/No 0-100 0 - 60000 0 - 900 Yes/No 0-3 Enable/Disable Enable/Disable 1 - 10 Enable/Disable Enable/Disable 36 UNITS min min min % sec CCN POINT DEFAULTS CTRLTYPE FAN_MODE RMTINCFG CEM_BRD TCSTCOOL TCSTHEAT SFS_SHUT SFS_MON SAMPMINS UNITSIZE DP_TRANS SPXRTYPE REFRIG_T COILTYPE MAT_SEL MATRESET MATOADOS ALTITUDE DELAY TSTATALL AUXRELAY 4 1 0 No 0 0 No 0 50 20 No 0 Unit dependent Unit dependent 1 No 20 0 0 No 0 SPTSENS SPTOSENS SPTO_RNG RARHSENS FLTS_ENA Disable Disable 5 Disable Disable mechanical cooling to allow for the greatest use of free cooling. When both mechanical cooling and the economizer are being used, the control will use the economizer to provide better temperature control and limit the cycling of the compressors. The control also checks on various other operation parameters in the unit to make sure that safeties are not exceeded and the compressors are reliably operated. The A Series ComfortLink™ control system offers two basic control approaches to mechanical cooling. Constant volume operation for 2 stages of cooling or VAV operation for multiple stages of cooling. In addition to these methods of control, the A Series ComfortLink control offers the ability to run multiple stages of cooling for either a space temperature sensor or thermostat by controlling the unit to either a low or high cool supply air set point. The control type Configuration UNITC.TYP) determines the selection of the type of cooling control as well as the method for selecting a cooling mode. There are either three or four compressors divided among two refrigeration circuits in the unit. Circuit A always contains two compressors (A1,A2). Circuit B has either one or two compressors (B1,B2). There may be a minimum load valve (MLV), which, if present, is only associated with circuit A. The decision as to which compressor should be turned on or off is decided by the compressor’s availability followed by a preferred staging order. NOTE: Configuration of the machine control type (C.TYP) has no effect on whether a unit has a VFD or just a supply fan installed for static pressure control. No matter what the control type is, it is possible to run the unit in either CV or VAV mode provided there are enough stages to accommodate lower air volumes for VAV operation. Refer to the section on static pressure control for information on how to set up the unit for the type of supply fan control desired. SETTING UP THE SYSTEM Machine Control Type (ConfigurationUNITC.TYP) — The most important cooling control configuration is located under ConfigurationUNIT. This configuration defines the method and control source responsible for selecting a cooling mode. The configuration also determines the method by which compressors are staged. Control types are: • C.TYP = 1 (VAV-RAT) and C.TYP = 2 (VAV-SPT) Both of these configurations refer to standard VAV operation. If the control is occupied, the supply fan is run continuously and return-air temperature will be used for both in the determination of the selection of a cooling mode. VAV-SPT differs from VAV-RAT only in that during the unoccupied period, space temperature will be used instead of return-air temperature to start the fan for ten minutes before the return-air temperature is allowed to call out any mode. • C.TYP = 3 (TSTAT-MULTI) This configuration will force the control to monitor the thermostat inputs to make a determination of mode. Unlike traditional 2-stage thermostat control, the unit is allowed to use multiple stages of cooling control and perform VAV style operation. The control will be able to call out a LOW COOL or a HIGH COOL mode and maintain a low or high cool supply air set point. • C.TYP = 4 (TSTAT-2 STG) This configuration will force the control to monitor the thermostat inputs to make a determination of mode. • C.TYP = 5 (SPT-MULTI) This configuration will force the control to monitor a space temperature sensor to make a determination of mode. Unlike traditional 2-stage space temperature control, the unit is allowed to use multiple stages of cooling control and perform VAV style operation. The control will be able to call Reset MAT Table Entries? (MAT.R) — This configuration allows the user to reset the internally stored MAT learned configuration data back to the default values. The defaults are set to a linear relationship between the economizer damper position and OAT and RAT in the calculation of MAT. MAT Outside Air Position Default (MAT.D) — This configuration is used to calculate MAT when the economizer option is disabled. The configuration is adjustable from 0 to 100% outside air. This defines the fixed ventilation position that will be used to correctly calculate MAT. Altitude……..In Feet: (ALTI) — The control does not include a barometric pressure sensor to determine altitude. The altitude must be defined the calculation of enthalpy and cfm. The altitude parameter is used to set up a default barometric pressure for use with calculations. The effect of barometric pressure in these calculations is not great, but could have an effect depending on the installed elevation of the unit. If the unit is installed at a particularly high altitude and enthalpy or cfm are being calculated, set this configuration to the current elevation. Start Up Delay Time (DLAY) — This option delays the unit from operating after a power reset. The configuration may be adjusted from 0 to 900 seconds of delay. TSTAT — Both Heat and Cool (STAT) — This option, if enabled, allows both heating and cooling requests to be made at the same time. If the unit is configured for staged gas heat, and if a cooling request is initiated (Y1 or Y2), then W1 initiates reheat and W2 initiates dehumidification. Auxiliary Relay Configuration (AUX.R) — This option configures the auxiliary relay on the MBB (RLY11). The function of this relay is configurable in the following ways: • AUX.R = 0 (Alarm Output) — The relay is used for remote annunciation of an alarm state. • AUX.R = 1 (Dehum-Reheat) — The relay is used as a dehumidification/reheat output. • AUX.R = 2 (Occup. State) — The relay is used to reflect occupancy. When the control is in occupied mode, the relay will be ON. When the control is in unoccupied mode, the relay will be OFF. • AUX.R = 3 (S. Fan State) — The relay is used to reflect the supply fan commanded state. When the supply fan is on, the relay will be ON. When the supply fan is off, the relay will be OFF. Space Temp Sensor (SPT.S) — If a space temperature sensor is installed, this configuration should be enabled. Space Temp Offset Sensor (SP.O.S) — If a space temperature sensor with a space temperature offset slider is installed (T56), this configuration should be enabled. Space Temp Offset Range (SP.O.R) — If a space temperature offset sensor is installed, it is possible to configure the range of the slider by adjusting this range configuration. Return RH Sensor (RRH.S) — If a return air relative humidity sensor is installed, this configuration should be enabled. Filter Status Switch Enabled? (FLT.S) — If a filter status switch is installed, enable this configuration to begin the monitoring of the filter status input (InputsGEN.IFLT.S). See the Dirty Filter Switch section for more details on installation and operation. Cooling Control — When mechanical cooling is required, the A Series ComfortLink™ control system has the capability to control the staging of the compressors in several different ways. Three scroll compressors are used on sizes 020 to 027 and four on sizes 030 to 060. In addition, the ComfortLink control system supports the use of an optional minimum load hot gas bypass valve (MLV) that is directly controlled by the ComfortLink control system. This provides an additional stage of capacity as well as low load coil freeze protection. The control also integrates the use of an economizer with the use of 37 SUPPLY AIR RESET CONFIGURATION — Supply Air Reset can be used to modify the current cooling supply air set point. Supply Air Reset is applicable to control types, C.TYP = 1,2,3, and 5. The configurations for reset can be found at the local display under ConfigurationEDT.R. See Table 46. EDT Reset Configuration (RS.CF) — This configuration applies to several machine control types (Configuration UNITC.TYP = 1,2,3, and 5). • 0 = NO RESET No supply air reset is in effect • 1 = SPT RESET Space temperature will be used as the reset control variable along with both RTIO and LIMT in the calculation of the final amount of reset to be applied (InputsRSET SA.S.R). • 2 = RAT RESET Return-air temperature will be used as the reset control variable along with both RTIO and LIMT in the calculation of the final amount of reset to be applied (InputsRSET SA.S.R). • 3 = 3RD PARTY RESET The reset value is determined by a 4 to 20 mA third party input. An input of 4 mA would correspond to 0º F reset. An input of 20 mA would correspond to 20º F reset. Configuring the control for this option will cause RES.S to become enabled automatically with the CEM board. To avoid alarms make sure the CEM board and third party input are connected first before enabling this option. Reset Ratio (RTIO) — This configuration is used when RS.CF is set to 1 or 2. For every degree that the controlling temperature (space/return) falls below the occupied cooling set point (OCSP), the calculated value of the supply air reset will rise by the number of degrees as specified by this parameter. Reset Limit (LIMT) — This configuration is used when RS.CF is set to 1 or 2. This configuration places a clamp on the amount of supply air reset that can be applied. EDT 4-20 mA Reset Input (RES.S) — This configuration is automatically enabled when ConfigurationEDT.R RS.CF is set to 3 (third party reset). COOLING CONFIGURATION — Relevant configurations for mechanical cooling are located at the local display under ConfigurationCOOL. See Table 47. out a LOW COOL or a HIGH COOL mode and maintain a low or high cool supply air set point. • C.TYP = 6 (SPT-2 STG) This configuration will force the control to monitor the space temperature sensor to make a determination of mode and allow two stages of cooling. MACHINE DEPENDENT CONFIGURATIONS — Some configurations are linked to the physical unit and must not be changed. The configurations are provided in case a field replacement of a board occurs and the settings are not preserved by the download process of the new software. The following configurations apply to all machine control types (C.TYP) except 4 and 6. These configurations are located at the local display under ConfigurationUNIT. See Table 44. Table 44 — Machine Dependent Configurations ITEM EXPANSION UNIT SIZE RFG.T CND.T RANGE UNIT CONFIGURATION Unit Size (20-60) 20-60 REFRIG 0-1 CND HX TYP 0-1 CCN POINT DEFAULTS UNITSIZE REFRIG_T COILTYPE * * * *Dependent on unit. Unit Size (SIZE) — There are several unit sizes (tons) for the A Series control. Make sure this configuration matches the size called out by the model number of the unit. This is important as the cooling stage tables are directly determined based on this configuration. Refrigerant Type (RFG.T) — This configuration specifies the type of refrigerant used in the unit. Configuration RFG.T is set to 0 if the refrigerant used is R-22. Configuration RFG.T is set to 1 if the refrigerant used is R-410A. Make sure this configuration matches the refrigerant called out by the model number of the unit. Condenser Type (CND.T) — This configuration specifies the type of condenser installed in the unit. Configuration CND.T is set to 0 if the condenser is a round tube, plate fin coil (RTPF). Configuration CND.T is set to 1 if the condenser is a microchannel heat exchanger coil (MCHX). Make sure this configuration matches the condenser type called out by the model number of the unit. SET POINTS — The set points for both cooling and heating are located at the local display under Setpoints. See Table 45. Table 45 — Setpoints ITEM OHSP OCSP UHSP UCSP GAP V.C.ON V.C.OF SASP SA.HI SA.LO SA.HT T.PRG T.CL T.V.OC T.V.UN EXPANSION Occupied Heat Setpoint Occupied Cool Setpoint Unoccupied Heat Setpoint Unoccupied Cool Setpoint Heat-Cool Setpoint Gap VAV Occ. Cool On Delta VAV Occ. Cool Off Delta Supply Air Setpoint Supply Air Setpoint Hi Supply Air Setpoint Lo Heating Supply Air Setpt Tempering Purge SASP Tempering in Cool SASP Tempering Vent Occ SASP Tempering Vent Unocc. SASP RANGE 40-99 40-99 40-99 40-99 2-10 0-25 1-25 45-75 45-75 45-75 90-145 –20-80 5-75 –20-80 –20-80 UNITS dF dF dF dF ^F ^F ^F dF dF dF dF dF dF dF dF CCN POINT OHSP OCSP UHSP UCSP HCSP_GAP VAVOCON VAVOCOFF SASP SASP_HI SASP_LO SASPHEAT TEMPPURG TEMPCOOL TEMPVOCC TEMPVUNC DEFAULT 68 75 55 90 5 3.5 2 55 55 60 85 50 5 65 50 Table 46 — Supply Air Reset Configuration ITEM EDT.R RS.CF RTIO LIMT RES.S EXPANSION EVAP.DISCHRGE TEMP RESET EDT Reset Configuration Reset Ratio Reset Limit EDT 4-20 ma Reset Input RANGE 0-3 0 - 10 0 - 20 Enable/Disable 38 UNITS ^F CCN POINT EDRSTCFG RTIO LIMT EDTRSENS DEFAULT 0 2 10 Disable Table 47 — Cooling Configuration ITEM COOL Z.GN MC.LO C.FOD MLV M.M. HPSP A1.EN A2.EN B1.EN B2.EN CS.A1 CS.A2 CS.B1 CS.B2 REV.R H.SST EXPANSION COOLING CONFIGURATION Capacity Threshold Adjst Compressor Lockout Temp Fan-Off Delay, Mech Cool Min. Load Valve (HGBP)? Motor Master Control ? Head Pressure Setpoint Enable Compressor A1 Enable Compressor A2 Enable Compressor B1 Enable Compressor B2 CSB A1 Feedback Alarm CSB A2 Feedback Alarm CSB B1 Feedback Alarm CSB B2 Feedback Alarm Rev. Rotation Verified? Hi SST Alert Delay Time RANGE UNITS –10 - 10 –20 - 55 0-600 Yes/No Yes/No 80 - 150 Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Yes/No 5 - 30 dF sec dF min Capacity Threshold Adjust (Z.GN) — This configuration is used for units using the “SumZ” algorithm for cooling capacity control (ConfigurationUNITC.TYP = 1, 2, 3 or 5). The configuration affects the cycling rate of the cooling stages by raising or lowering the threshold that demand must rise above in order to add or subtract a stage of cooling. Normally this configuration should not require any tuning or adjustment. If there is an application where the unit may be significantly oversized and there are indications of high compressor cycles, then the Capacity Threshold Adjust (Z.GN) can be used to adjust the overall logic gain. Normally this is set to 1.0, but it can be adjusted from 0.5 to 4.0. As the value of Z.GN is increased, the cycling of cooling stages will be slowed. Compressor Lockout Temperature (MC.LO) — This configuration is the outdoor air temperature setting below which mechanical cooling is locked out. Fan-Off Delay, Mech Cool (C.FOD) — After a mechanical cooling cycle has ended, this is the delay in seconds that the supply fan will continue to operate. Min. Load Valve (HGBP)? (MLV) — This configuration instructs the control as to whether a minimum load valve has been installed and will be controlled by the compressor staging routine. MotorMaster Control? (M.M.) — The condenser fan staging control for the unit is managed directly by the ComfortLink™ controls. There is no physical Motormaster® device in the standard unit. The standard unit is capable of mechanical cooling operation down to 32 F outdoor temperature. With the addition of accessory Motormaster V speed control on the stage 1 condenser fan(s), mechanical cooling operation down to –20 F outdoor temperature is possible. The accessory Motormaster V speed control is a completely self-contained device and is not managed by the unit’s ComfortLink controller. The Motormaster control configuration (M.M.) only applies to the 060 size RTPF units. On 060 size RTPF units with accessory Motormaster V speed control installed, this configuration must be set to YES. See Head Pressure Control section, page 49, for more information. Head Pressure Set Point (HPSP) — This is the head pressure set point used by the ComfortLink control during condenser fan, head pressure control. Enable Compressor A1 (A1.EN) — This configuration is used to disable the A1 compressor in case of failure. Enable Compressor A2 (A2.EN) — This configuration is used to disable the A2 compressor in case of failure. Enable Compressor B1 (B1.EN) — This configuration is used to disable the B1 compressor in case of failure. Enable Compressor B2 (B2.EN) — This configuration is used to disable the B2 compressor in case of failure. CSB A1 Feedback Alarm (CS.A1) — This configuration is used to enable or disable the compressor A1 feedback alarm. This configuration must be enabled at all times. CCN POINT Z_GAIN OATLCOMP COOL_FOD MLV_SEL MOTRMAST HPSP CMPA1ENA CMPA2ENA CMPB1ENA CMPB2ENA CSB_A1EN CSB_A2EN CSB_B1EN CSB_B2EN REVR_VER HSSTTIME DEFAULT 1 40 60 No No 113 Enable Enable Enable Enable Enable Enable Enable Enable No 10 (48/50AJ,AK,AW,AY) 20 (48/50A2,A3,A4,A5) CSB A2 Feedback Alarm (CS.A2) — This configuration is used to enable or disable the compressor A2 feedback alarm. This configuration must be enabled at all times. CSB B1 Feedback Alarm (CS.B1) — This configuration is used to enable or disable the compressor B1 feedback alarm. This configuration must be enabled at all times. CSB B2 Feedback Alarm (CS.B2) — This configuration is used to enable or disable the compressor B2 feedback alarm. This configuration must be enabled at all times. Reverse Rotation Verified? (REV.R) — If this configuration is set to NO, then after a power up, in the normal run mode, the control will check the suction pressure on the first circuit that is energized after 5 seconds of run time. If the control does not see a sufficient decrease in suction pressure over the first 5 seconds, mechanical cooling will be shut down, and an alarm will be generated (A140). This alarm requires a manual reset. If the unit is in the Service Test mode, the test will be performed any time a compressor is energized. Once it has been verified that power to the rooftop and compressors has been applied correctly and the compressors start up normally, this configuration can be set to YES in order to prevent the reverse rotation check from occurring. High SST Alert Delay Time (H.SST) — This option allows the high saturated suction temperature alert timing delay to be adjusted. COMPRESSOR SAFETIES — The 48/50A Series units with ComfortLink™ controls include a compressor protection board (CSB) that protects the operation of each of the compressors. These boards sense the presence or absence of current to each compressor. If there is a command for a compressor to run and there is no current, then one of the following safeties or conditions have turned the compressor off: • Compressor overcurrent — Smaller compressors have internal line breaks and larger compressors have a dedicated circuit breaker for overcurrent protection. • Compressor short circuit — the compressor circuit breaker that provides short circuit protection has tripped then there will not be current. • Compressor motor over temperature — the internal linebreak or over temperature switch has opened. • High-pressure switch trip — High-pressure switch has opened. Alarms will also occur if the current sensor board malfunctions or is not properly connected to its assigned digital input. If the compressor is commanded OFF and the Current Sensor reads ON, an alert is generated. This will indicate that a compressor contactor has failed closed. In this case, a special mode “Compressor Stuck on Control” will be enabled and all other compressors will be turned off and an alarm enabled to indicate that service is required. Indoor and outdoor fans will continue to operate. The first outdoor fan stage is turned on immediately. The second fan stage will turn on when outdoor-air 39 will run until the motor protector trips, which occurs up to 90 minutes later. Advanced scroll temperature protection will reset automatically before the motor protector resets, which may take up to 2 hours. COMPRESSOR TIME GUARDS — The control will not allow any output relay to come on within 3 seconds of any other output relay. For outputs connected to the compressors, the control will use a Compressor Minimum OFF Time of 2 minutes, a Compressor Minimum ON Time of 3 minutes and a Minimum Delay before turning on another compressor of 10 seconds. COOL MODE SELECTION PROCESS — The A Series ComfortLink™ controls offer three distinct methods by which it may select a cooling mode. 1. Thermostat (C.TYP=3 and 4): The thermostat does not depend upon the state of occupancy and the modes are called out directly by the discrete inputs from the thermostat (InputsSTATY1 and Y2). 2. Occupied VAV cooling types (C.TYP=1 and 2) are called out in the occupied period (Operating ModesMODE OCC=ON). 3. Unoccupied VAV cooling types (C.TYP=1 and 2) are called out in the unoccupied period (Operating ModesMODEOCC=OFF). They are also used for space sensor control types (C.TYP=5 and 6) in both the occupied and unoccupied periods. This section is devoted to the process of cooling mode determination for the three types outlined above. VAV Cool Mode Selection during the Occupied Period (C.TYP = 1,2 and Operating ModesMODEOCC =ON) — There is no difference in the selection of a cooling mode for either VAV-RAT or VAV-SPT in the occupied period. The actual selection of a cool mode, for both control types, is based upon the controlling return-air temperature (TemperaturesAIR.T CTRLR.TMP). Typically this is the same as the return air temperature thermistor (TemperaturesAIR.TRAT) except when under CCN Linkage. VAV Occupied Cool Mode Evaluation Configuration — There are VAV occupied cooling offsets under Setpoints. temperature (OAT) rises above 75 F or the highest active circuit saturated condensing temperature (SCT) rises above the HPSP and remains on until the condition is repaired regardless of the OAT and SCT values. Any time the alert occurs, a strike is called out on the affected compressor. If three successive strikes occur the compressor will be locked out requiring a manual reset or power reset of the circuit board. The clearing of strikes during compressor operation is a combination of 3 complete cycles or 15 continuous minutes of run time operation. If there are one or two strikes on the compressor and three short cycles (ON-OFF, ON-OFF, ON-OFF) less than 15 minutes each occur, the strikes are reset to zero for the affected compressor. If the compressor turns on and runs for 15 minutes straight with no compressor failure, the compressor strikes are cleared. Additionally, some units contain Copeland compressors equipped with advanced scroll temperature protection (ASTP). A label located above the terminal box identifies Copeland Scroll compressor models that contain this technology. See Fig. 5. Advanced scroll temperature protection is a form of internal discharge temperature protection that unloads the scroll compressor when the internal temperature reaches approximately 300 F. At this temperature, an internal bi-metal disk valve opens and causes the scroll elements to separate, which stops compression. Suction and discharge pressures balance while the motor continues to run. The longer the compressor runs unloaded, the longer it must cool before the bi-metal disk resets. See Fig. 6. To manually reset ASTP, the compressor should be stopped and allowed to cool. If the compressor is not stopped, the motor ITEM V.C.ON V.C.OF Recommended Cooling Time (Minutes) 120 110 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 RANGE UNITS CCN POINT DEFAULT 0-25 ^F VAVOCON 3.5 1-25 ^F VAVOCOFF 2 Cool Mode Determination — If the machine control type (ConfigurationUNITC.TYP) = 1 (VAV-RAT) or 2 (VAVSPT) and the control is occupied (Operating Modes MODEOCC=ON), then the unit will not follow the occupied cooling set point (OCSP). Instead, the control will follow two offsets in the determination of an occupied VAV cooling mode (SetpointsV.C.ON and SetpointsV.C.OF), applying them to the low-heat off trip point and comparing the resulting temperature to the return-air temperature. The SetpointsV.C.ON (VAV cool mode on offset) and SetpointsV.C.OF (VAV cool mode off offset) offsets are used in conjunction with the low heat mode off trip point to determine when to bring cooling on and off and in enforcing a true “vent” mode between heating and cooling. See Fig. 7. The occupied cooling set point is not used in the determination of the cool mode. The occupied cooling set point is used for supply air reset only. Fig. 5 — Advanced Scroll Temperature Protection Label 0 EXPANSION VAV Occ. Cool On Delta VAV Occ. Cool Off Delta 90 Compressor Unloaded Run Time (Minutes) *Times are approximate. NOTE: Various factors, including high humidity, high ambient temperature, and the presence of a sound blanket will increase cooldown times. V.C. ON OHSP V.C. OF L.H.ON L.H.OF Fig. 6 — Recommended Minimum Cool-Down Time After Compressor is Stopped* A48-7700 Fig. 7 — VAV Occupied Period Trip Logic 40 The advantage of this offset technique is that the control can safely enforce a vent mode without worrying about crossing set points. Even more importantly, under CCN linkage, the occupied heating set point may drift up and down and this method ensures a guaranteed separation in degrees Fahrenheit between the calling out of a heating or cooling mode at all times. NOTE: There is a sub-menu at the local display (Run Status TRIP) that allows the user to see the exact trip points for both the heating and cooling modes without having to calculate them. Refer to the Cooling Mode Diagnostic Help section on page 46 for more information. To enter into a VAV Occupied Cool mode, the controlling temperature must rise above [OHSP minus L.H.ON plus L.H.OF plus V.C.ON]. To exit out of a VAV Occupied Cool Mode, the controlling temperature must fall below [OHSP minus L.H.ON plus L.H.OF plus V.C.ON minus V.C.OF]. NOTE: With vent mode, it is possible to exit out of a cooling mode during the occupied period if the return-air temperature drops low enough. When supply-air temperature reset is not configured, this capability will work to prevent over-cooling the space during the occupied period. Supply Air Set Point Control and the Staging of Compressors — Once the control has determined that a cooling mode is in effect, the cooling control point (Run StatusVIEW CL.C.P) is calculated and is based upon the supply air set point (SetpointsSASP) plus any supply air reset being applied (InputsRSETSA.S.R). Refer to the SumZ Cooling Algorithm section on page 46 for a discussion of how the A Series ComfortLink™ controls manage the staging of compressors to maintain supply-air temperature. VAV Cool Mode Selection during the Unoccupied Period (C.TYP = 1,2; Operating ModesMODEOCC=OFF) and Space Sensor Cool Mode Selection (C.TYP=5 and 6) — The machine control types that use this type of mode selection are: • C.TYP = 1 (VAV-RAT) in the unoccupied period • C.TYP = 2 (VAV-SPT) in the unoccupied period • C.TYP = 5 (SPT-MULTI) in both the occupied and unoccupied period • C.TYP = 6 (SPT-2 STG) in both the occupied and unoccupied period These particular control types operate differently than the VAV types in the occupied mode in that there is both a LOW COOL and a HIGH COOL mode. For both of these modes, the control offers two independent set points, SetpointsSA.LO (for LOW COOL mode) and SetpointsSA.HI (for HIGH COOL mode). The occupied and unoccupied cooling set points can be found under Setpoints. ITEM OCSP UCSP EXPANSION Occupied Cool Setpoint Unoccupied Cool Setpoint dF CCN POINT OCSP 75 dF UCSP 90 RANGE UNITS 55-80 75-95 or is in the temperature compensated start mode (T.C.ST). If the unit is occupied or in temperature compensated start mode, the occupied cooling set point (OCSP) is used. For all other modes, the unoccupied cooling set point (UCSP) is used. For further discussion and simplification this will be referred to as the “cooling set point.” See Fig. 8. Demand Level Low Cool On Offset (L.C.ON) — This is the cooling set point offset added to the cooling set point at which point a Low Cool mode starts. Demand Level High Cool On Offset (H.C.ON) — This is the cooling set point offset added to the “cooling set point plus L.C.ON” at which point a High Cool mode begins. Demand Level Low Cool Off Offset (L.C.OF) — This is the cooling set point offset subtracted from “cooling set point plus L.C.ON” at which point a Low Cool mode ends. NOTE: The “high cool end” trip point uses the “low cool off” (L.C.OF) offset divided by 2. To enter into a LOW COOL mode, the controlling temperature must rise above the cooling set point plus L.C.ON. To enter into a HIGH COOL mode, the controlling temperature must rise above the cooling set point plus L.C.ON plus H.C.ON. To exit out of a LOW COOL mode, the controlling temperature must fall below the cooling set point plus L.C.ON minus L.C.OF. To exit out of a HIGH COOL mode, the controlling temperature must fall below the cooling set point plus L.C.ON minus L.C.OF/2. Comfort Trending — In addition to the set points and offsets which determine the trip points for bringing on and bringing off cool modes, there are 2 configurations which work to hold off the transitioning from a low cool to a high cool mode if the space is cooling down quickly enough. This method is referred to as Comfort Trending. The comfort trending configurations are C.T.LV and C.T.TM. Cool Trend Demand Level (C.T.LV) — This is the change in demand that must occur within the time period specified by C.T.TM in order to hold off a HIGH COOL mode regardless of demand. This is not applicable to VAV control types (C.TYP=1 and 2) in the occupied period. As long as a LOW COOL mode is making progress in cooling the space, the control will hold off on the HIGH COOL mode. This is especially true for the space sensor machine control types (C.TYP = 5 and 6), because they may transition into the occupied mode and see an immediate large cooling demand when the set points change. Cool Trend Time (C.T.TM) — This is the time period upon which the cool trend demand level (C.T.LV) operates and may hold off staging or a HIGH COOL mode. This is not applicable to VAV control types (C.TYP=1 and 2) in the occupied period. See the Cool Trend Demand Level section for more details. DEFAULT Hi Cool Start H.C.ON The heat/cool set point offsets are found under ConfigurationD.LV.T. See Table 48. Operating modes are under Operating ModesMODE. ITEM MODE OCC T.C.ST EXPANSION RANGE MODES CONTROLLING UNIT Currently Occupied ON/OFF Temp.Compensated Start ON/OFF Lo Cool Start L.C. OF L.C.ON CCN POINT MODEOCCP MODETCST L.C. OF/2 Hi Cool End Lo Cool End Cooling Setpoint (OCSP,UCSP) Cool Mode Evaluation Logic — The first thing the control determines is whether the unit is in the occupied mode (OCC) Fig. 8 — Cool Mode Evaluation 41 A48-7701 Table 48 — Cool/Heat Set Point Offsets Configuration ITEM D.LV.T L.H.ON H.H.ON L.H.OF L.C.ON H.C.ON L.C.OF C.T.LV H.T.LV C.T.TM H.T.TM EXPANSION COOL/HEAT SETPT. OFFSETS Dmd Level Lo Heat On Dmd Level(+) Hi Heat On Dmd Level(-) Lo Heat Off Dmd Level Lo Cool On Dmd Level(+) Hi Cool On Dmd Level(-) Lo Cool Off Cool Trend Demand Level Heat Trend Demand Level Cool Trend Time Heat Trend Time RANGE -1 - 2 0.5 - 20.0 0.5 - 2 -1 - 2 0.5 - 20.0 0.5 - 2 0.1 - 5 0.1 - 5 30 - 600 30 - 600 UNITS ^F ^F ^F ^F ^F ^F ^F ^F sec sec CCN POINT DMDLHON DMDHHON DMDLHOFF DMDLCON DMDHCON DMDLCOFF CTRENDLV HTRENDLV CTRENDTM HTRENDTM DEFAULT 1.5 0.5 1 1.5 0.5 1 0.1 0.1 120 120 are staged and the timing involved for both the Low Cool and High Cool HVAC Modes. There are either three or four compressors divided among two refrigeration circuits. Circuit A always contains two compressors (OutputsCOOLA1 and A2). Circuit B has either one compressor (OutputsCOOLB1) on size 020-027 units or two compressors (OutputsCOOLB1 and B2) on size 030-060 units. For 2-stage cooling control, regardless of configuration, there is no minimum load valve (MLV) control. The decision as to which compressor should be turned on or off next is decided by the compressor’s availability and the preferred staging order. Either A1 or A2 may start first as there is a built-in lead/lag logic on compressors A1 and A2 every time the unit stages to 0 compressors. Also, based on compressor availability, it should be noted that any compressor may come on. For example, on a 3 compressor unit, if no compressors are currently on, compressor A2 is currently under a minimum off compressor timeguard, and 2 compressors are to be turned on, then compressors A1 and B1 will be turned on immediately instead of A1 and A2. Low Cool Versus High Cool Mechanical Staging — The number of compressors to be requested during a cooling mode are divided into 2 groups by the control, HVAC mode = Lo Cool and HVAC mode = Hi Cool. If the economizer is not able to provide free cooling (Run StatusECONACTV = NO) then the following staging occurs: • Lo Cool Mode mechanical stages = 2 • Hi Cool Mode mechanical stages = 3 (for 020 through 027 size units) • Hi Cool Mode mechanical stages = 4 (for 030 through 060 size units) If the economizer is able to provide free cooling (Run StatusECONACTV = YES) then the following staging occurs: 1. If the economizer’s current position is less than ConfigurationECONEC.MX – 5 and mechanical cooling has not yet started for the current cool mode session then: Lo Cool Mode mechanical stages = 0 Hi Cool Mode mechanical stages = 0 2. During the first 2.5 minutes of a low or high cool mode where the economizer position is greater than Configuration ECONEC.MX – 5% and mechanical cooling has not yet started: Lo Cool Mode mechanical stages = 0 Hi Cool Mode mechanical stages = 0 3. If the economizer position is greater than Configuration ECONEC.MX – 5% for more than 2.5 minutes but less than 5.5 minutes and mechanical cooling has not yet started then: Lo Cool Mode mechanical stages = 1 Hi Cool Mode mechanical stages = 1 4. If the economizer position is greater than Configuration ECONEC.MX – 5% for more than 5.5 minutes but less than 8 minutes and mechanical cooling has started Timeguards — In addition to the set points and offsets which determine the trip points for bringing on and bringing off cool modes there is a timeguard of 8 minutes which enforces a time delay between the transitioning from a low cool to a high cool mode. There is a timeguard of 5 minutes which enforces a time delay between the transitioning from a heat mode to a cool mode. Supply Air Set Point Control — Once the control has determined that a cooling mode is in effect, the cooling control point (Run StatusVIEWCL.C.P) is calculated and is based upon either SetpointsSA.HI or SetpointsSA.LO, depending on whether a high or a low cooling mode is in effect, respectively. In addition, if supply air reset is configured, it will also be added to the cooling control point. Refer to the SumZ Cooling Algorithm section for a discussion of how the A Series ComfortLink™ controls manage supply-air temperature and the staging of compressors for these control types. Thermostat Cool Mode Selection (C.TYP = 3 and 4) — When a thermostat type is selected, the decision making process involved in determining the mode is straightforward. Upon energizing the Y1 input only, the unit HVAC mode will be LOW COOL. Upon the energizing of both Y1 and Y2 inputs, the unit HVAC mode will be HIGH COOL. If just input G is energized the unit HVAC mode will be VENT and the supply fan will run. Selecting the C.TYP = 3 (TSTAT – MULTI) control type will cause the control to do the following: • The control will read the ConfigurationUNIT SIZE configuration parameter to determine the number of cooling stages and the pattern for each stage. • An HVAC mode equal to LOW COOL will cause the unit to select the SetpointsSA.LO set point to control to. An HVAC mode equal to HIGH COOL will cause the unit to select the SetpointsSA.HI set point to control to. Supply air reset (if configured) will be added to either the low or high cool set point. • The control will utilize the SumZ cooling algorithm and control cooling to a supply air set point. See the section for the SumZ Cooling Algorithm section for information on controlling to a supply air set point and compressor staging. Selecting the C.TYP = 4 (TSTAT – 2 STG) control type means that only two stages of cooling will be used. On unit sizes 020, 025 and 027 (with three compressors), an HVAC Mode of LOW COOL will energize one compressor in Circuit A; an HVAC Mode of HIGH COOL will energize all three compressors. On unit sizes 030 and larger (with four compressors) an HVAC Mode of LOW COOL will energize both compressors in Circuit A; an HVAC Mode of HIGH COOL will energize all four compressors. Refer to the section on Economizer Integration with Mechanical Cooling for more information. 2-Stage Cooling Control Logic (C.TYP = 4 and 6) — The logic that stages mechanical cooling for the TSTAT and SPT 2-Stage cooling control types differs from that of the multistage control types. This section will explain how compressors 42 If the set point cannot be satisfied or the economizer is not active, then cooling will be brought on one stage at a time when the evaporator discharge temperature (EDT) is greater the 1.5° F above the current cooling control point. A start-up time delay of 10 minutes and steady state delay after a compressor is energized of 5 minutes is enforced. If both circuits of mechanical cooling are running, then the economizer will attempt to control to 48 F. If the economizer is active and the outside-air temperature (OAT) is less than the cooling control point + 0.5 F, the compressors will be locked off. When mechanical cooling is on, the control may also use the economizer to trim the leaving-air temperature to prevent unnecessary cycles of the compressor stages. See the Economizer Integration with Mechanical Cooling section on page 50 for more information on the holding off of mechanical cooling as well as the economizer control point. then Lo Cool Mode mechanical stages = 2 and Hi Cool Mode mechanical stages = 2. 5. If the economizer position is greater than Configuration ECONEC.MX – 5% for more than 8 minutes but less than 11.5 minutes and mechanical cooling has started then: Lo Cool Mode mechanical stages = 2 Hi Cool Mode mechanical stages = 3 6. If the economizer position is greater than Configuration ECONEC.MX – 5% for more than 11.5 minutes and mechanical cooling has started then: Lo Cool Mode mechanical stages = 2 Hi Cool Mode mechanical stages = 3 (for 020 to 027 units only) Hi Cool Mode mechanical stages = 4 (for 030 to 060 units only) NOTE: If some compressors are not available due to being faulted, the Hi Cool Mode number of compressors are affected before the Lo Cool Mode number of compressors. For example, if a 4 compressor unit has one compressor faulted, and the economizer is not active, then an HVAC mode Hi Cool requested number of compressors is changed from 4 to 3. If another compressor faults, then both Lo Cool and Hi Cool requested number of compressors are set to 2. In addition, compressors cannot be brought on faster than one every 30 seconds. If the control needs to bring on 2 compressors at once, the first compressor will come on followed by the second compressor 30 seconds later. Staging of compressors is shown in Tables 49-60. EDT Low Override — There is an override if EDT drops too low based on an alert limit that will lock out cooling. If the supply air/evaporator discharge temperature (EDT) falls below the alert limit (ConfigurationALLMSA.L.O) cooling will be inhibited. There is a 20-minute hold off on starting cooling again once the following statement is true: EDT minus (Run StatusCOOLSUMZADD.R) has risen above SA.L.O. The variable ADD.R is one of the SumZ cooling algorithm control variables dedicated mainly for multi-stage control. 2-Stage Control and the Economizer — The 2-stage logic will first check for the availability of the economizer. If free cooling can be used, then the control will first attempt to use the free cooling. If no mechanical cooling is active, and the economizer is active, the economizer will first attempt to control to a cooling control point of either the supply air set point high (SA.HI) or supply air set point low (SA.LO) plus any reset applied, depending on whether High Cool or Low Cool mode is in effect, respectively. If one stage of mechanical cooling is on, and the economizer is active, then the economizer will attempt to control to 53 F. Also If HVAC mode = LOW COOL, the second stage of mechanical cooling will be locked out. Table 49 — 2-Stage Sequence — 48/50AJ,AW020-027 SEQUENCE 1 SEQUENCE 2 1 2 0 1 2 Thermostat Inputs Thermostat Inputs Y1 OPEN CLOSED CLOSED OPEN CLOSED CLOSED Y2 OPEN OPEN CLOSED OPEN OPEN CLOSED COMP Compressor Status Compressor Status A1 OFF ON ON OFF OFF ON A2 OFF OFF ON OFF ON ON B1 OFF OFF ON OFF OFF ON UNIT Unit Capacity Unit Capacity 020 0% 33% 100% 0% 33% 100% 025 0% 30% 100% 0% 30% 100% 027 0% 33% 100% 0% 33% 100% STAGE 0 Table 50 — 2-Stage Sequence — 48/50AJ,AW030-060 STAGE Y1 Y2 COMP A1 A2 B1 B2 UNIT 030 035,036 040,041 050 051,060 SEQUENCE 1 SEQUENCE 2 1 2 0 1 2 Thermostat Inputs Thermostat Inputs OPEN CLOSED CLOSED OPEN CLOSED CLOSED OPEN OPEN CLOSED OPEN OPEN CLOSED Compressor Status Compressor Status OFF ON ON OFF ON ON OFF ON ON OFF ON ON OFF OFF ON OFF OFF ON OFF OFF ON OFF OFF ON Unit Capacity Unit Capacity 0% 45% 100% 0% 45% 100% 0% 48% 100% 0% 48% 100% 0% 43% 100% 0% 43% 100% 0% 45% 100% 0% 45% 100% 0% 50% 100% 0% 50% 100% 0 Table 51 — Staging Sequence without Hot Gas Bypass — 48/50AK,AY020-027 and Multi-Stage 48/50AJ,AW020-027 STAGE COMP A1 A2 B1 UNIT 020 025 027 0 OFF OFF OFF 0% 0% 0% SEQUENCE 1 2 3 Compressor Status ON ON OFF OFF ON ON OFF OFF ON Unit Capacity 48/50A 33% 67% 67% 30% 65% 70% 33% 67% 67% 1 4 0 ON ON ON OFF OFF OFF 100% 100% 100% 0% 0% 0% 43 SEQUENCE 2 2 3 Compressor Status OFF ON ON ON ON OFF OFF OFF ON Unit Capacity 48/50A 33% 67% 67% 35% 65% 65% 33% 67% 67% 1 4 ON ON ON 100% 100% 100% Table 52 — Staging Sequence with Hot Gas Bypass — 48/50AK,AY020-027 and Multi-Stage 48/50AJ,AW020-027 STAGE COMP A1 A2 B1 UNIT 020 025 027 0 1 OFF OFF OFF ON* OFF OFF 0% 0% 0% 18% 17% 21% SEQUENCE 1 2 3 Compressor Status ON ON OFF ON OFF OFF Unit Capacity 48/50A 33% 67% 30% 65% 33% 67% 4 5 0 1 OFF ON ON ON ON ON OFF OFF OFF OFF ON* OFF 67% 70% 67% 100% 100% 100% 0% 0% 0% 18% 22% 21% SEQUENCE 2 2 3 Compressor Status OFF ON ON ON OFF OFF Unit Capacity 48/50A 33% 67% 35% 65% 33% 67% 4 5 ON OFF ON ON ON ON 67% 65% 67% 100% 100% 100% 4 5 ON ON OFF ON ON ON ON ON 73% 74% 72% 77% 75% 76% 100% 100% 100% 100% 100% 100% *With Minimum Load Valve ON. Table 53 — Staging Sequence without Hot Gas Bypass — 48/50AK,AY030-060 and Multi-Stage 48/50AJ,AW030-060 STAGE COMP A1 A2 B1 B2 UNIT 030 035,036 040,041 050 051 060 0 1 OFF OFF OFF OFF ON OFF OFF OFF 0% 0% 0% 0% 0% 0% 23% 22% 21% 23% 25% 24% SEQUENCE 1 2 3 Compressor Status ON OFF ON ON OFF ON OFF OFF Unit Capacity 48/50A 45% 50% 48% 52% 43% 50% 46% 46% 50% 50% 50% 50% 4 5 0 1 ON ON ON OFF ON ON ON ON OFF OFF OFF OFF OFF ON OFF OFF 73% 74% 71% 68% 75% 74% 100% 100% 100% 100% 100% 100% 0% 0% 0% 0% 0% 0% 23% 26% 21% 23% 25% 26% SEQUENCE 2 2 3 Compressor Status ON ON ON OFF OFF OFF OFF ON Unit Capacity 48/50A 45% 50% 48% 48% 43% 50% 46% 54% 50% 50% 50% 50% Table 54 — Staging Sequence with Hot Gas Bypass — 48/50AK,AY030-060 STAGE COMP A1 A2 B1 B2 UNIT 030 035,036 040,041 050 051 060 0 1 OFF OFF OFF OFF ON* OFF OFF OFF 0% 0% 0% 0% 0% 0% 12% 12% 13% 16% 19% 19% SEQUENCE 1 2 3 4 Compressor Status ON ON OFF OFF ON ON OFF OFF ON OFF OFF OFF Unit Capacity 48/50A 23% 45% 50% 22% 48% 52% 21% 43% 50% 23% 46% 46% 25% 50% 50% 24% 50% 50% 5 6 0 1 ON ON ON OFF ON ON ON ON OFF OFF OFF OFF OFF ON* OFF OFF 73% 74% 71% 68% 75% 74% 100% 100% 100% 100% 100% 100% 0% 0% 0% 0% 0% 0% 12% 16% 13% 16% 19% 21% SEQUENCE 2 2 3 4 Compressor Status OFF ON ON ON ON OFF OFF OFF OFF ON OFF ON Unit Capacity 48/50A 23% 45% 50% 26% 48% 48% 21% 43% 50% 23% 46% 54% 25% 50% 50% 26% 50% 50% 5 6 ON ON OFF ON ON ON ON ON 73% 74% 72% 77% 75% 76% 100% 100% 100% 100% 100% 100% *With minimum load valve ON. Table 55 — 2-Stage Sequence — 48/50A2,A4020-027 Table 56 — 2-Stage Sequence — 48/50A2,A4030-060 SEQUENCE 1 SEQUENCE 2 1 2 0 1 2 Thermostat Inputs Thermostat Inputs Y1 OPEN CLOSED CLOSED OPEN CLOSED CLOSED Y2 OPEN OPEN CLOSED OPEN OPEN CLOSED COMP Compressor Status Compressor Status A1 OFF ON ON OFF OFF ON A2 OFF OFF ON OFF ON ON B1 OFF OFF ON OFF OFF ON UNIT Unit Capacity Unit Capacity 020 0% 30% 100% 0% 30% 100% 025 0% 33% 100% 0% 33% 100% 027 0% 33% 100% 0% 33% 100% STAGE SEQUENCE 1 SEQUENCE 2 1 2 0 1 2 Thermostat Inputs Thermostat Inputs Y1 OPEN CLOSED CLOSED OPEN CLOSED CLOSED Y2 OPEN OPEN CLOSED OPEN OPEN CLOSED COMP Compressor Status Compressor Status A1 OFF ON ON OFF OFF ON A2 OFF OFF ON OFF ON ON B1 OFF ON ON OFF OFF ON B2 OFF OFF ON OFF ON ON UNIT Unit Capacity Unit Capacity 030 0% 50% 100% 0% 50% 100% 035 0% 50% 100% 0% 50% 100% 040 0% 50% 100% 0% 50% 100% 050 0% 50% 100% 0% 50% 100% 060 0% 50% 100% 0% 50% 100% STAGE 0 44 0 Table 57 — Staging Sequence without Hot Gas Bypass — 48/50A3,A5020-027 and Multi-Stage 48/50A2,A4020-027 STAGE SEQUENCE 1 1 2 Compressor Status ON ON OFF OFF OFF ON Unit Capacity 48/50A 30% 70% 33% 67% 33% 67% 0 COMP A1 A2 B1 UNIT 020 025 027 OFF OFF OFF 0% 0% 0% 3 0 ON ON ON OFF OFF OFF 100% 100% 100% 0% 0% 0% SEQUENCE 2 1 2 Compressor Status OFF OFF ON ON OFF ON Unit Capacity 48/50A 30% 70% 33% 67% 33% 67% 3 ON ON ON 100% 100% 100% Table 58 — Staging Sequence with Hot Gas Bypass — 48/50A3,A5020-027 and Multi-Stage 48/50A2,A4020-027 STAGE SEQUENCE 1 2 3 Compressor Status ON* ON ON OFF OFF OFF OFF OFF ON Unit Capacity 48/50A 10% 30% 70% 17% 33% 67% 17% 33% 67% 0 COMP A1 A2 B1 UNIT 020 025 027 1 OFF OFF OFF 0% 0% 0% 4 0 ON ON ON OFF OFF OFF 100% 100% 100% 0% 0% 0% SEQUENCE 2 2 3 Compressor Status OFF OFF OFF ON* ON ON OFF OFF ON Unit Capacity 48/50A 10% 30% 70% 17% 33% 67% 17% 33% 67% 1 4 ON ON ON 100% 100% 100% *With Minimum Load Valve ON. Table 59 — Staging Sequence without Hot Gas Bypass — 48/50A3,A5030-060 and Multi-Stage 48/50A2,A4030-060 STAGE COMP A1 A2 B1 B2 UNIT 030 035 040 050 060 0 1 OFF OFF OFF OFF ON OFF OFF OFF 0% 0% 0% 0% 0% 25% 20% 25% 25% 25% SEQUENCE 1 2 3 Compressor Status ON ON OFF ON ON ON OFF OFF Unit Capacity 48/50A 50% 75% 50% 80% 50% 75% 50% 75% 50% 75% 4 0 1 ON ON ON ON OFF OFF OFF OFF OFF ON OFF OFF 100% 100% 100% 100% 100% 0% 0% 0% 0% 0% 25% 20% 25% 25% 25% SEQUENCE 2 2 3 Compressor Status ON OFF OFF ON ON ON OFF ON Unit Capacity 48/50A 50% 75% 50% 70% 50% 75% 50% 75% 50% 75% 4 ON ON ON ON 100% 100% 100% 100% 100% Table 60 — Staging Sequence with Hot Gas Bypass — 48/50A3,A5030-060 STAGE COMP A1 A2 B1 B2 UNIT 030 035 040 050 060 0 1 OFF OFF OFF OFF ON* OFF OFF OFF 0% 0% 0% 0% 0% 10% 7% 14% 16% 18% SEQUENCE 1 2 3 Compressor Status ON ON OFF OFF OFF ON OFF OFF Unit Capacity 48/50A 25% 50% 20% 50% 25% 50% 25% 50% 25% 50% 4 5 0 1 ON ON ON OFF ON ON ON ON OFF OFF OFF OFF OFF ON* OFF OFF 75% 80% 75% 75% 75% 100% 100% 100% 100% 100% 0% 0% 0% 0% 0% 10% 7% 14% 16% 18% *With minimum load valve ON. 45 SEQUENCE 2 2 3 Compressor Status OFF OFF ON ON OFF OFF OFF ON Unit Capacity 48/50A 25% 50% 20% 50% 25% 50% 25% 50% 25% 50% 4 5 OFF ON ON ON ON ON ON ON 75% 70% 75% 75% 75% 100% 100% 100% 100% 100% COOLING MODE DIAGNOSTIC HELP — To quickly determine the current trip points for the cooling modes, the Run Status sub-menu at the local display allows the user to view the calculated start and stop points for both the cooling and heating trip points. The following sub-menu can be found at the local display under Run StatusTRIP. See Table 61. The controlling temperature is “TEMP” and is in the middle of the table for easy reference. The HVAC mode can also be viewed at the bottom of the table. SUMZ COOLING ALGORITHM — The SumZ cooling algorithm is an adaptive PID which is used by the control whenever more than 2 stages of cooling are present (C.TYP = 1,2,3, and 5). This section will describe its operation and define its parameters. It is generally not necessary to modify parameters in this section. The information is presented primarily for reference and may be helpful for troubleshooting complex operational problems. The only configuration parameter for the SumZ algorithm is located at the local display under Configuration COOLZ.GN. See Table 47. should drop in degrees depending on the R.PCT calculation and exactly how much additional capacity is to be added. ADD.R = R.PCT * (C.CAP — capacity after adding a cooling stage) For example: If R.PCT = 0.2 and the control would be adding 20% cooling capacity by taking the next step up, 0.2 times 20 = 4 F (ADD.R). Next Stage EDT Increase (SUB.R) — This variable represents (if subtracting a stage of cooling) how much the temperature should rise in degrees depending on the R.PCT calculation and exactly how much capacity is to be subtracted. SUB.R = R.PCT * (C.CAP — capacity after subtracting a cooling stage) For Example: If R.PCT = 0.2 and the control would be subtracting 30% capacity by taking the next step down, 0.2 times –30 = –6 F (SUB.R) Rise Per Percent Capacity (R.PCT) — This is a real time calculation that represents the amount of degrees of drop/rise across the evaporator coil versus percent of current running capacity. R.PCT = (MAT – EDT)/ C.CAP Cap Deadband Subtracting (Y.MIN) — This is a control variable used for Low Temp Override (L.TMP) and Slow Change Override (SLOW). Y.MIN = -SUB.R*0.4375 Cap Deadband Adding (Y.PLU) — This is a control variable used for High Temp Override (H.TMP) and Slow Change Override (SLOW). Y.PLU = -ADD.R*0.4375 Cap Threshold Subtracting (Z.MIN) — This parameter is used in the calculation of SumZ and is calculated as follows: Z.MIN = ConfigurationCOOLZ.GN * (–10 + (4* (–SUB.R))) * 0.6 Cap Threshold Adding (Z.PLU) — This parameter is used in the calculation of SumZ and is calculated as follows: Z.PLU = ConfigurationCOOLZ.GN * (10 + (4* (–ADD.R))) * 0.6 High Temp Cap Override (H.TMP) — If stages of mechanical cooling are on and the error is greater than twice Y.PLU, and the rate of change of error is greater than 0.5F per minute, then a stage of mechanical cooling will be added every 30 seconds. This override is intended to react to situations where the load rapidly increases. Low Temp Cap Override (L.TMP) — If the error is less than twice Y.MIN, and the rate of change of error is less than –0.5F per minute, then a mechanical stage will be removed every 30 seconds. This override is intended to quickly react to situations where the load is rapidly reduced. Pull Down Cap Override (PULL) — If the error from set point is above 4F, and the rate of change is less than –1F per minute, then pulldown is in effect, and “SUM” is set to 0. This keeps mechanical cooling stages from being added when the error is very large, but there is no load in the space. Pulldown for units is expected to rarely occur, but is included for the rare situation when it is needed. Most likely pulldown will occur when mechanical cooling first becomes available shortly after the control goes into an occupied mode (after a warm unoccupied mode). Table 61 — Run Status Mode Trip Helper ITEM TRIP UN.C.S UN.C.E OC.C.S OC.C.E TEMP OC.H.E OC.H.S UN.H.E UN.H.S HVAC EXPANSION MODE TRIP HELPER Unoccup. Cool Mode Start Unoccup. Cool Mode End Occupied Cool Mode Start Occupied Cool Mode End Ctl.Temp RAT,SPT or Zone Occupied Heat Mode End Occupied Heat Mode Start Unoccup. Heat Mode End Unoccup. Heat Mode Start the current HVAC MODE UNITS dF dF dF dF dF dF dF dF dF CCN POINT UCCLSTRT UCCL_END OCCLSTRT OCCL_END CTRLTEMP OCHT_END OCHTSTRT UCHT_END UCHTSTRT String Capacity Threshold Adjust (Z.GN) — This configuration is used on units using the “SumZ” algorithm for cooling capacity control (ConfigurationUNITC.TYP = 1, 2, 3 and 5). It affects the cycling rate of the cooling stages by raising or lowering the threshold that capacity must overcome in order to add or subtract a stage of cooling. The cooling algorithm’s run-time variables are located at the local display under Run StatusCOOL. See Table 62. Current Running Capacity (C.CAP) — This variable represents the amount of capacity in percent that is currently running. Current Cool Stage (CUR.S) — This variable represents the cool stage currently running. Requested Cool Stage (REQ.S) — This variable represents the cool stage currently requested by the control. Maximum Cool Stages (MAX.S) — This variable is the maximum number of cooling stages the control is configured for and capable of controlling. Active Demand Limit (DEM.L) — If demand limit is active, this variable will represent the amount of capacity that the control is currently limited to. Capacity Load Factor (SMZ) — This factor builds up or down over time (–100 to +100) and is used as the means of adding or subtracting a cooling stage during run time. It is a normalized representation of the relationship between “Sum” and “Z”. Next Stage EDT Decrease (ADD.R) — This variable represents (if adding a stage of cooling) how much the temperature 46 Table 62 — Run Status Cool Display ITEM COOL C.CAP CUR.S REQ.S MAX.S DEM.L SUMZ SMZ ADD.R SUB.R R.PCT Y.MIN Y.PLU Z.MIN Z.PLU H.TMP L.TMP PULL SLOW EXPANSION COOLING INFORMATION Current Running Capacity Current Cool Stage Requested Cool Stage Maximum Cool Stages Active Demand Limit COOL CAP. STAGE CONTROL Capacity Load Factor Next Stage EDT Decrease Next Stage EDT Increase Rise Per Percent Capacity Cap Deadband Subtracting Cap Deadband Adding Cap Threshold Subtracting Cap Threshold Adding High Temp Cap Override Low Temp Cap Override Pull Down Cap Override Slow Change Cap Override RANGE UNITS % % -100 – +100 ^F ^F CCN POINT CAPTOTAL COOL_STG CL_STAGE CLMAXSTG DEM_LIM WRITE STATUS forcible SMZ ADDRISE SUBRISE RISE_PCT Y_MINUS Y_PLUS Z_MINUS Z_PLUS HI_TEMP LOW_TEMP PULLDOWN SLO_CHNG 2) the amount of expected rise for the next cooling stage addition 3) the amount of expected rise for the next cooling stage subtraction The calculation of “Z” requires two variables, Z.PLU used when adding a stage and Z.MIN used when subtracting a stage. They are calculated with the following formulas: Z.PLU = Z.GN * (10 + (4*(–ADD.R))) * 0.6 Z.MIN = Z.GN * (–10 + (4*(–SUB.R))) * 0.6 Where: Z.GN = configuration used to modify the threshold levels used for staging (ConfigurationCOOLZ.GN) ADD.R = R.PCT * (C.CAP – capacity after adding a cooling stage) SUB.R = R.PCT * (C.CAP – capacity after subtracting a cooling stage) Both of these terms, Z.PLU and Z.MIN, represent a threshold both positive and negative upon which the “SUM” calculation must build up to in order to cause the compressor to stage up or down. Comparing SUM and Z — The “SUM” calculation is compared against Z.PLU and Z.MIN. • If “SUM” rises above Z.PLU, a cooling stage is added. • If “SUM” falls below Z.MIN, a cooling stage is subtracted. There is a variable called SMZ which is described in the reference section and which can simplify the task of watching the demand build up or down over time. It is calculated as follows: If SUM is positive: SMZ = 100*(SUM/Z.PLU) If SUM is negative: SMZ = –100*(SUM/Z.MIN) Mixed Air Temperature Calculation (MAT) — The mixedair temperature is calculated and is a function of the economizer position. Additionally there are some calculations in the control which can zero in over time on the relationship of return and outside air as a function of economizer position. There are two configurations which relate to the calculation of “MAT.” These configurations can be located at the local display under ConfigurationUNIT. Slow Change Cap Override (SLOW) — With a rooftop unit, the design rise at 100% total unit capacity is generally around 30 F. For a unit with 4 stages, each stage represents about 7.5F of change to EDT. If stages could reliably be cycled at very fast rates, the set point could be maintained very precisely. Since it is not desirable to cycle compressors more than 6 cycles per hour, slow change override takes care of keeping the PID under control when “relatively” close to set point. SumZ Operation — The SumZ algorithm is an adaptive PID style of control. The PID is programmed within the control and the relative speed of staging can only be influenced by the user through the adjustment of the Z.GN configuration. The capacity control algorithm uses a modified PID algorithm, with a self adjusting gain which compensates for varying conditions, including changing flow rates across the evaporator coil. Previous implementations of SumZ made static assumptions about the actual size of the next capacity jump up or down. This control uses a “rise per percent capacity” technique in the calculation of SumZ, instead of the previous “rise per stage” method. For each jump, up or down in capacity, the control will know beforehand the exact capacity change brought on. Better overall staging control can be realized with this technique. SUM Calculation — The PID calculation of the “SUM” is evaluated once every 80 seconds. SUM = Error + “SUM last time through” + (3 * Error Rate) Where: SUM = the PID calculation, Error = EDT – Cooling Control Point, Error Rate = Error – “Error last time through” NOTE: “Error” is limited to between –50 and +50 and “Error rate” is limited to between –20 and +20. This “SUM” will be compared against the “Z” calculations in determining whether cooling stages should be added or subtracted. Z Calculation — For the “Z” calculation, the control attempts to determine the entering and the leaving-air temperature of the evaporator coil and based upon the difference between the two during mechanical cooling, and then determines whether to add or subtract a stage of cooling. This is the adaptive element. The entering-air temperature is referred to as MAT (mixed-air temperature) and the leaving-air temperature of the evaporator coil is referred to as EDT (evaporator discharge temperature). They are found at the local display under the TemperaturesCTRL sub-menu. The main elements to be calculated and used in the calculation of SumZ are: 1) the rise per percent capacity (R.PCT) ITEM UNIT MAT.S MAT.R 47 EXPANSION RANGE UNIT CONFIGURATION MAT Calc Config 0-2 Reset MAT Table Yes/No Entries? CCN POINT MAT_SEL MATRESET DEFAULTS 1 No MAT Calc Config (MAT.S) — This configuration gives the user two options in the processing of the mixed-air temperature (MAT) calculation: • MAT.S = 0 There will be no MAT calculation. • MAT.S = 1 The control will attempt to learn MAT over time. Any time the system is in a vent mode and the economizer stays at a particular position for long enough, MAT = EDT. Using this method, the control has an internal table whereby it can more closely determine the true MAT value. • MAT.S = 2 The control will not attempt to learn MAT over time. To calculate MAT linearly, the user should reset the MAT table entries by setting MAT.R to YES. Then set MAT.S = 2. The control will calculate MAT based on the position of the economizer and outside air and return air temperature. To freeze the MAT table entries, let the unit run with MAT.S = 1. Once sufficient data has been collected, change MAT.S = 2. Do not reset the MAT table. Reset MAT Table Entries? (MAT.R) — This configuration allows the user to reset the internally stored MAT learned configuration data back to the default values. The defaults are set to a linear relationship between the economizer damper position and OAT and RAT in the calculation of MAT. SumZ Overrides — There are a number of overrides to the SumZ algorithm which may add or subtract stages of cooling. • High Temp Cap Override (H.TMP) • Low Temp Cap Override (L.TMP) • Pull Down Cap Override (PULL) • Slow Change Cap Override (SLOW) Economizer Trim Override — The unit may drop stages of cooling when the economizer is performing free cooling and the configuration ConfigurationECONE.TRM is set to Yes. The economizer controls to the same supply air set point as mechanical cooling does for SumZ when E.TRM = Yes. This allows for much tighter temperature control as well as cutting down on the cycling of compressors. For a long cooling session where the outside-air temperature may drop over time, there may be a point at which the economizer has closed down far enough were the unit could remove a cooling stage and open up the economizer further to make up the difference. Mechanical Cooling Lockout (ConfigurationCOOL MC.LO) — This configuration allows a configurable outsideair temperature set point below which mechanical cooling will be completely locked out. DEMAND LIMIT CONTROL — Demand Limit Control may override the cooling algorithm to limit or reduce cooling capacity during run time. The term Demand Limit Control refers to the restriction of machine capacity to control the amount of power that a machine will use. This can save the owner money by limiting peaks in the power supply. Demand limit control is intended to interface with an external Loadshed Device either through CCN communications, external switches, or 4 to 20 mA input. The control has the capability of loadshedding and limiting in 3 ways: • Two discrete inputs tied to configurable demand limit set point percentages. • An external 4 to 20 mA input that can reset capacity back linearly to a set point percentage. • CCN loadshed functionality. NOTE: It is also possible to force the demand limit variable (Run StatusCOOLDEM.L). To use Demand Limiting, select the type of demand limiting to use. This is done with the Demand Limit Select configuration (ConfigurationDMD.LDM.L.S). To view the current demand limiting currently in effect, look at Run StatusCOOLDEM.L. The configurations associated with demand limiting can be viewed at the local display at ConfigurationDMD.L. See Table 63. Demand Limit Select (DM.L.S) — This configuration determines the type of demand limiting. • 0 = NONE — Demand Limiting not configured. • 1 = 2 SWITCHES — This will enable switch input demand limiting using the switch inputs connected to the CEM board. Connections should be made to TB6-4,5,6. • 2 = 4 to 20 mA — This will enable the use of a remote 4 to 20 mA demand limit signal. The CEM module must be used. The 4 to 20 mA signal must come from an externally sourced controller and should be connected to TB6-7,8. • 3 = CCN LOADSHED — This will allow for loadshed and red lining through CCN communications. Two-Switch Demand Limiting (DM.L.S = 1) — This type of demand limiting utilizes two discrete inputs: Demand Limit Switch 1 Setpoint (D.L.S1) — Dmd Limit Switch Setpoint 1 (0-100% total capacity) Demand Limit 2 Setpoint (D.L.S2) — Dmd Limit Switch Setpoint 2 (0-100% total capacity) The state of the discrete switch inputs can be found at the local display: InputsGEN.IDL.S1 InputsGEN.IDL.S2 The following table illustrates the demand limiting (Run StatusCOOLDEM.L) that will be in effect based on the logic of the applied switches: Switch Status InputsGEN.IDL.S1 = OFF InputsGEN.IDL.S2 = OFF InputsGEN.IDL.S1= ON InputsGEN.IDL.S2 = OFF InputsGEN.IDL.S1= ON InputsGEN.IDL.S2 = ON InputsGEN.IDL.S1= OFF InputsGEN.IDL.S2 = ON Run StatusCOOLDEM.L = 1 100% ConfigurationDMD.LD.L.S1 ConfigurationDMD.LD.L.S2 ConfigurationDMD.LD.L.S2 4-20 mA Demand Limiting (DM.L.S = 2) — If the unit has been configured for 4 to 20 mA demand limiting, then the Inputs4-20DML.M value is used to determine the amount of demand limiting in effect (Run StatusCOOLDEM.L). The Demand Limit at 20 mA (D.L.20) configuration must be set. This is the configured demand limit corresponding to a 20 mA input (0 to 100%). The value of percentage reset is determined by a linear interpolation from 0% to “D.L.20”% based on the Inputs 4-20DML.M input value. The following examples illustrate the demand limiting (Run StatusCOOLDEM.L) that will be in effect based on amount of current seen at the 4 to 20 mA input, DML.M. D.L.20 = 80% DML.M = 4mA DEM.L = 100% D.L.20 = 80% DML.M = 12 mA DEM.L = 90% D.L.20 = 80% DML.M = 20mA DEM.L = 80% CCN Loadshed Demand Limiting (DM.L.S = 3) — If the unit has been configured for CCN Loadshed Demand Limiting, then the demand limiting variable (Run StatusCOOL DEM.L) is controlled via CCN commands. 48 Table 63 — Demand Limit Configuration ITEM DMD.L DM.L.S D.L.20 SH.NM SH.DL SH.TM D.L.S1 D.L.S2 EXPANSION DEMAND LIMIT CONFIG. Demand Limit Select Demand Limit at 20 ma Loadshed Group Number Loadshed Demand Delta Maximum Loadshed Time Demand Limit Sw.1 Setpt. Demand Limit Sw.2 Setpt. RANGE 0-3 0 - 100 0 - 99 0 - 60 0 - 120 0 - 100 0 - 100 UNITS % % min % % CCN POINT DMD_CTRL DMT20MA SHED_NUM SHED_DEL SHED_TIM DLSWSP1 DLSWSP2 DEFAULT 0 100 0 0 60 80 50 unit size (ConfigurationUnitSIZE) is 60 tons and the condenser heat exchanger type (ConfigurationUnit CND.T) is RTPF (round tube plate fin). This is because the condenser fan relay A (MBB Relay 6) output must be energized to enable the Motormaster V control and must not be turned off by the head pressure control algorithm. The size 60 ton unit with RTPF condenser heat exchangers offers 3 stages of head pressure control and is the one case where condenser fan relay A may be requested off during head pressure control operation. By configuring M.M. to YES, the control is instructed not to turn off the relay to attempt 3 stages of head pressure control. There are two configurations provided for head pressure control that can be found at the local display: • ConfigurationCOOLM.M. – Motor Master Control? • ConfigurationCOOLHPSP – Head Pressure Setpoint There are two outputs (MBB Relays) provided to control head pressure: • OutputsFANSCD.F.A – Condenser Fan Circuit A (MBB Relay 6 - OFC1,4). For size 60 ton units with MCHX condensers, MBB – Relay 6 drives OFC4 and compressor contactor B1 or B2 auxiliary contacts drive OFC1. • OutputsFANSCD.F.B – Condenser Fan Circuit B (MBB Relay 5 - OFC2) Head Pressure Control Operation — The following logic describes the head pressure control routines for the unit sizes outlined in Table 64. For 020 to 035 size units, there are two outdoor fans that are common to both refrigerant circuits. The control cycles two stages of outdoor fans, one fan per stage, to maintain acceptable head pressure. For 036 to 050 size units, there are four outdoor fans that are common to both refrigerant circuits. The control cycles two stages of outdoor fans, two fans per stage, to maintain acceptable head pressure. For 051 and 060 size units – There are six outdoor fans that are common to both refrigerant circuits (size 060 MCHX units have 4 fans). The control cycles three stages of outdoor fans, two fans for stage one, four fans for stage two, and six fans for stage three to maintain acceptable head pressure. When a compressor has been commanded on, then condenser fan A (MBB Relay 6) will be energized (CD.F.A = ON). Condenser fan A will remain on until all compressors have been commanded off. If the highest active circuit SCT is above the HPSP or if OAT is greater than 75 F then condenser fan B (MBB Relay 5) will be energized (CD.F.B = ON). Condenser fan B will remain on until all compressors have been commanded off, or the highest active circuit SCT drops 40 F below the HPSP for greater than 2 minutes and OAT is less than 73 F. NOTE: For size 60 units with RTPF condenser heat exchangers not configured for Motormaster control, the control stages down differently than the other units. For these units, the control will first turn off condenser fan relay A. After 2 minutes, the control will turn off relay B and turn back on relay A. The relevant configurations for this type of demand limiting are: Loadshed Group Number (SH.NM) — CCN Loadshed Group number Loadshed Demand Delta (SH.DL) — CCN Loadshed Demand Delta Maximum Loadshed Time (SH.TM) — CCN Maximum Loadshed time The Loadshed Group Number (SH.NM) corresponds to the loadshed supervisory device that resides elsewhere on the CCN network and broadcasts loadshed and redline commands to its associated equipment parts. The SH.NM variable will default to zero which is an invalid group number. This allows the loadshed function to be disabled until configured. Upon reception of a redline command, the machine will be prevented from starting if it is not running. If it is running, then DEM.L is set equal to the current running cooling capacity (Run StatusCOOLC.CAP). Upon reception of a loadshed command, the DEM.L variable is set to the current running cooling capacity (Run Status COOLC.CAP) minus the configured Loadshed Demand Delta (SH.DL). A redline command or loadshed command will stay in effect until a Cancel redline or Cancel loadshed command is received, or until the configurable Maximum Loadshed time (SH.TM) has elapsed. HEAD PRESSURE CONTROL — Condenser head pressure control for the 48/50A series rooftops is controlled directly by the unit, except when the unit is equipped and configured for Motormaster® V control. The control is able to cycle up to three stages of outdoor fans (see Table 64) to maintain acceptable head pressure. For 48/50AJ,AK,AW,AY units, fan stages will react to saturated condensing temperature (SCT) sensors (TemperaturesREF.TSCT.A and SCT.B) which are connected to the condenser coils in circuit A and B. The control converts the temperatures to the corresponding refrigerant pressures (PressuresREF.PDP.A and DP.B). For 48/50A2,A3,A4,A5 units, fan stages react to discharge pressure transducers (DPT) (PressuresREF.PDP.A and DP.B) which are connected to the compressor discharge piping in circuit A and B. The control converts the pressures to the corresponding saturated condensing temperatures (TemperaturesREF.TSCT.A and SCT.B). Unit size (ConfigurationUnitSize), refrigerant type (ConfigurationUnitRFG.T), and condenser heat exchanger type (ConfigurationUnitCND.T) are used to determine if the second stage fans are configured to respond to a particular refrigerant circuit (independent control) or both refrigerant circuits (common control). The 48/50A2,A3, A4,A5060 units with microchannel (MCHX) condenser heat exchangers are the only units that utilize independent fan controls. If the unit is equipped with the accessory Motormaster V control, the Motormaster installed configuration (ConfigurationCOOLM.M.) must be set to YES if the 49 Table 64 — Condenser Fan Staging FAN RELAY OFC1,4* (MBB - RELAY 6) OFC2 (MBB - RELAY 5) OFC3 C.A1-AUX or C.A2-AUX OFC1* C.B1-AUX or C.B2-AUX 020-035 OFM1 OFM2 NA NA 036-050 OFM1, OFM2 OFM3, OFM4 NA NA 48/50A UNIT SIZE 051,060 OFM1, OFM2 OFM3, OFM4, OFM5, OFM6 NA NA 060 with MCHX OFM4 OFM2 OFM3 OFM1 * For size 60 ton units with MCHX condensers, MBB – Relay 6 drives OFC4 and compressor contactor B1 or B2 auxiliary contacts drive OFC1. If the economizer is able to provide free cooling at the start of a cooling session, the mechanical cooling algorithm checks the economizer’s current position (Run Status ECONECN.P) and compares it to the economizer’s maximum position (ConfigurationECONEC.MX) – 5%. Once the economizer has opened beyond this point a 2.5-minute timer starts. If the economizer stays beyond this point for 2.5 minutes continuously, the mechanical cooling algorithm is allowed to start computing demand and stage compressors. Economizer Control Point (Run StatusVIEWEC.C.P) — There are 4 different ways to determine the economizer control point when the economizer is able to provide free cooling: If no mechanical cooling is active and HVAC mode = LOW COOL EC.C.P = SetpointsSA.LO + InputsRSETSA.S.R If no mechanical cooling is active and HVAC mode = HIGH COOL EC.C.P = SetpointsSA.HI + InputsRSETSA.S.R When the first stage of mechanical cooling has started EC.C.P = 53 F plus any economizer suction pressure reset applied When the second stage of mechanical cooling has started EC.C.P = 48 F plus any economizer suction pressure reset applied For 060 size units with MCHX condensers, there are four outdoor fans, two for each independent refrigerant circuit. The control cycles two stages of outdoor fans for each circuit, one fan per stage, to maintain acceptable head pressure. When a circuit A compressor has been commanded on, then OFC3 is energized via the normally opened auxiliary contacts on the compressor contactors. The auxiliary contacts are wired such that turning on either circuit A compressor will energize OFC3. Contactor OFC3 will remain on until all circuit A compressors have been commanded off. If SCTA is above the HPSP or if OAT is greater than 75 F, then condenser fan A (MBB Relay 6) will be energized (CD.F.A = ON) turning on OFC4. Condenser fan A will remain on until all compressors have been commanded off, or SCTA drops 40 F below the HPSP for greater than 2 minutes and OAT is less than 73 F. When a circuit B compressor has been commanded on, then OFC1 is energized via the normally opened auxiliary contacts on the compressor contactors. The auxiliary contacts are wired such that turning on either circuit B compressor will energize OFC1. Contactor OFC1 will remain on until all circuit B compressors have been commanded off. If SCTB is above the HPSP or if OAT is greater than 75 F, then condenser fan B (MBB Relay 5) will be energized (CD.F.B = ON) turning on OFC2. Condenser fan B will remain on until all compressors have been commanded off, or SCTB drops 40 F below the HPSP for greater than 2 minutes and OAT is less than 73 F. Failure Mode Operation — If either of the SCT or DPT sensors fails, then the control defaults to head pressure control based on the OAT sensor. The control turns on the second fan stage when the OAT is above 65 F and stages down when OAT drops below 50 F. If the OAT sensor fails, then the control defaults to head pressure control based on the SCT sensors. The control turns on the second fan stage when the highest active circuit SCT is above the HPSP and stages down when the highest active circuit SCT drops 40 F below the HPSP for longer than 2 minutes. If the SCT, DPT, and OAT sensors have all failed, then the control turns on the first and second fan stages when any compressor is commanded on. Compressor current sensor boards (CSB) are used on all units and are able to diagnose a compressor stuck on (welded contactor) condition. If the control commands a compressor off and the CSB detects current flowing to the compressor, then the first fan stage is turned on immediately. The second fan stage will turn on when OAT rises above 75 F or the highest active circuit SCT rises above the HPSP and remain on until the condition is repaired regardless of the OAT and SCT values. ECONOMIZER INTEGRATION WITH MECHANICAL COOLING — When the economizer is able to provide free cooling (Run StatusECONACTV = YES), mechanical cooling may be delayed or even held off indefinitely. NOTE: Once mechanical cooling has started, this delay logic is no longer relevant. Economizer Mechanical Cooling Delay — This type of mechanical cooling delay is relevant to the all machine control types. Heating Control — The A Series ComfortLink™ control system offers control for 3 different types of heating systems to satisfy general space heating requirements: 2-stage gas heat, 2-stage electric heat and multiple-stage (staged) gas heat. Variable air volume (VAV) type applications (C.TYP = 1, 2, 3, or 5) require that the space terminal positions be commanded to open to Minimum Heating positions when gas or electric heat systems are active, to provide for the unit heating system’s Minimum Heating Airflow rate. For VAV applications, the heat interlock relay (HIR) function provides the switching of a control signal intended for use by the VAV terminals. This signal must be used to command the terminals to open to their Heating Open positions. The HIR is energized whenever the Heating mode is active, an IAQ preoccupied force is active, or if fire smoke modes, pressurization, or smoke purge modes are active. SETTING UP THE SYSTEM — The heating configurations are located at the local display under Configuration HEAT. See Table 65. Heating Control Type (HT.CF) — The heating control types available are selected with this variable. 0 = No Heat 1 = Electric Heat 2 = 2 Stage Gas Heat 3 = Staged Gas Heat Heating Supply Air Set Point (HT.SP) — In a low heat mode for staged gas heat, this is the supply air set point for heating. 50 Table 65 — Heating Configuration ITEM HEAT HT.CF HT.SP OC.EN LAT.M G.FOD E.FOD SG.CF HT.ST CAP.M M.R.DB S.G.DB RISE LAT.L LIM.M SW.H.T SW.L.T HT.P HT.D HT.TM EXPANSION HEATING CONFIGURATION Heating Control Type Heating Supply Air Setpt Occupied Heating Enabled MBB Sensor Heat Relocate Fan Off Delay, Gas Heat Fan Off Delay, Elec Heat STAGED GAS CONFIGS Staged Gas Heat Type Max Cap Change per Cycle S.Gas DB min.dF/PID Rate St.Gas Temp. Dead Band Heat Rise dF/sec Clamp LAT Limit Config Limit Switch Monitoring? Limit Switch High Temp Limit Switch Low Temp Heat Control Prop. Gain Heat Control Derv. Gain Heat PID Rate Config RANGE UNITS 0-3 80 - 120 Yes/No Yes/No 45 - 600 10 - 600 dF sec sec 0-4 5 - 45 0-5 0-5 0.05 - 0.2 0 - 20 Yes/No 110 - 180 100 - 170 0 - 1.5 0 - 1.5 60 - 300 ^F ^F dF dF sec CCN POINT DEFAULT HEATTYPE SASPHEAT HTOCCENA HTLATMON GAS_FOD ELEC_FOD 0* 85 No No 45 30 HTSTGTYP HTCAPMAX HT_MR_DB HT_SG_DB HTSGRISE HTLATLIM HTLIMMON HT_LIMHI HT_LIMLO HT_PGAIN HT_DGAIN HTSGPIDR 0* 45* 0.5 2 0.06 10 Yes 170* 160* 1 1 90 *Some defaults are model number dependent. VAV-RAT or VAV-SPT, except that for VAV-SPT, space temperature is used in the unoccupied period to turn on the supply fan for 10 minutes before checking return-air temperature. The actual selection of a heat mode, LOW or HIGH for both control types, will be based upon the controlling return-air temperature. With sufficient heating demand, there are still conditions that will prevent the unit from selecting a heat mode. First, the unit must be configured for a heat type (Configuration HEATHT.CF not equal to “NONE”). Second, the unit has a configuration which can enable or disable heating in the occupied period except for a standard morning warmup cycle (ConfigurationHEATOC.EN). See descriptions above in the Setting Up the System section for more information. If the unit is allowed to select a heat mode, then the next step is an evaluation of demand versus set point. At this point, the logic is the same as for control types SPT Multi-Stage and SPT-2 Stage, (C.TYP = 5,6) except for the actual temperature compared against set point. See Temperature Driven Heat Mode Evaluation section. Tstat-Multi-Stage (C.TYP = 3) and Tstat-2 Stage (C.TYP = 4) — There is no difference in the selection of a heat mode between the control types TSTAT 2-stage or TSTAT multi-stage. These selections only refer to how cooling will be handled. With thermostat control the W1 and W2 inputs determine whether the HVAC Mode is LOW or HIGH HEAT. W1 = ON, W2 = OFF: HVAC MODE = LOW HEAT* W2 = ON, W2 = ON: HVAC MODE = HIGH HEAT *If the heating type is either 2-stage electric or 2-stage gas, the unit may promote a low heat mode to a high heat mode. NOTE: If W2 = ON and W1 is OFF, a “HIGH HEAT” HVAC Mode will be called out but an alert (T422) will be generated. See Alarms and Alerts section on page 93. SPT Multi-Stage (C.TYP = 5) and SPT 2 Stage (C.TYP = 6) — There is no difference in the selection of a heat mode between the control types SPT 2-stage or SPT multi-stage. These selections only refer to how cooling will be handled. So, for a valid heating type selected (HT.CF not equal to zero) the unit is free to select a heating mode based on space temperature (SPT). If the unit is allowed to select a heat mode, then the next step is an evaluation of demand versus set point. At this point, the logic is the same as for control types VAV-RAT and VAV-SPT (C.TYP = 1,2), except for the actual temperature compared against set point. See Temperature Driven Heat Mode Evaluation section on page 52. Occupied Heating Enable (OC.EN) — This configuration only applies when the unit’s control type (Configuration UNITC.TYP) is configured for 1 (VAV-RAT) or 2 (VAVSPT). If the user wants to have the capability of performing heating throughout the entire occupied period, then this configuration needs to be set to “YES”. Most installations do not require this capability, and if heating is installed, it is used to heat the building in the morning. In this case set OC.EN to “NO”. NOTE: This unit does not support simultaneous heating and cooling. If significant simultaneous heating and cooling demand is expected, it may be necessary to provide additional heating or cooling equipment and a control system to provide occupants with proper comfort. MBB Sensor Heat Relocate (LAT.M) — This option allows the user additional performance benefit when under CCN Linkage for the 2-stage electric and gas heating types. As twostage heating types do not “modulate” to a supply air set point, no leaving air thermistor is required and none is provided. The evaporator discharge thermistor, which is initially installed upstream of the heater, can be repositioned downstream and the control can expect to sense this heat. While the control does not need this to energize stages of heat, the control can wait for a sufficient temperature rise before announcing a heating mode to a CCN linkage system (ComfortID™). If the sensor is relocated, the user will now have the capability to view the leaving-air temperature at all times at TemperaturesAIR.TCTRLLAT. NOTE: If the user does not relocate this sensor for the 2-stage electric or gas heating types and is under CCN Linkage, then the control will send a heating mode (if present) unconditionally to the linkage coordinator in the CCN zoning system regardless of the leaving-air temperature. Fan-Off Delay, Gas Heat (G.FOD) — This configuration is the delay in seconds, after a gas heat mode has ended (HT.CF=2,3) that the control will continue to energize the supply fan. Fan-Off Delay, Elec Heat (E.FOD) — This configuration is the delay in seconds, after an electric heat mode has ended (HT.CF=1) that the control will continue to energize the supply fan. HEAT MODE SELECTION PROCESS — There are two possible heat modes that the control will call out for heating control: HVAC Mode = LOW HEAT and HVAC Mode = HIGH HEAT. These modes will be called out based on control type (C.TYP). VAV-RAT (C.TYP = 1) and VAV-SPT (C.TYP = 2) — There is no difference in the selection of a heating mode for either 51 To get out of a HIGH HEAT mode, the controlling temperature must rise above the heating set point minus L.H.ON plus L.H.OF/2. The Run Status table in the local display allows the user to see the exact trip points for both the heating and cooling modes without doing the calculations. Heat Trend Demand Level (H.T.LV) — This is the change in demand that must be seen within the time period specified by H.T.TM in order to hold off a HIGH HEAT mode regardless of demand. This is not applicable to VAV control types (C.TYP=1 and 2) in the occupied period. This method of operation has been referred to as “Comfort Trending.” As long as a LOW HEAT mode is making progress in warming the space, the control will hold off on a HIGH HEAT mode. This is relevant for the space sensor machine control types (C.TYP = 5 and 6) because they may transition into the occupied mode and see an immediate and large heating demand when the set points change. Heat Trend Time (H.T.TM) — This is the time period upon which the heat trend demand level (H.T.LV) operates and may work to hold off staging or a HIGH HEAT mode. This is not applicable to VAV control types (C.TYP=1 and 2) in the occupied period. See “Heat Trend Demand Level” section for more details. HEAT MODE DIAGNOSTIC HELP — To quickly determine the current trip points for the low and high heat modes, there is a menu in the local display which lets the user quickly view the state of the system. This menu also contains the cool trip points as well. See Table 67 at the local display under Run StatusTRIP. The controlling temperature is “TEMP” and is in the middle of the table for easy reference. Also, the “HVAC” mode can be viewed at the bottom of the table. HT.CF = 1,2 (Two-Stage Gas and Electric Heat Control) If the HVAC mode is LOW HEAT: • If Electric Heat is configured, then the control will request the supply fan ON • If Gas Heat is configured, then the IGC indoor fan input controls the supply fan request • The control will turn on Heat Relay 1 (HS1) • If Evaporator Discharge Temperature is less than 50 F, then the control will turn on Heat Relay 2 (HS2)* TEMPERATURE DRIVEN HEAT MODE EVALUATION — This section discusses the control method for selecting a heating mode based on temperature. Regardless of whether the unit is configured for return air or space temperature, the logic is exactly the same. For the rest of this discussion, the temperature in question will be referred to as the “controlling temperature.” First, the occupied and unoccupied heating set points under Setpoints must be configured. ITEM OHSP UHSP EXPANSION RANGE UNITS Occupied Heat 55-80 Setpoint Unoccupied 40-80 Heat Setpoint CCN POINT DEFAULT dF OHSP 68 dF UHSP 55 Then, the heat/cool set point offsets under Configuration D.LV.T should be set. See Table 66. Related operating modes are under Operating Modes MODE. ITEM MODE OCC T.C.ST EXPANSION RANGE MODES CONTROLLING UNIT Currently Occupied ON/OFF Temp.Compensated Start ON/OFF CCN POINT MODEOCCP MODETCST The first thing the control determines is whether the unit is in the occupied mode (OCC) or in the temperature compensated start mode (T.C.ST). If the unit is occupied or in temperature compensated start mode, the occupied heating set point (OHSP) is used. In all other cases, the unoccupied heating setpoint (UHSP) is used. The control will call out a low or high heat mode by comparing the controlling temperature to the heating set point and the heating set point offset. The set point offsets are used as additional help in customizing and tweaking comfort into the building space. Demand Level Low Heat on Offset (L.H.ON) — This is the heating set point offset below the heating set point at which point Low Heat starts. Demand Level High Heat on Offset (H.H.ON) — This is the heating set point offset below the heating set point minus L.H.ON at which point high heat starts. Demand Level Low Heat Off Offset (L.H.OF) — This is the heating set point offset above the heating set point minus L.H.ON at which point the Low Heat mode ends. See Fig. 9 for an example of offsets. To enter into a LOW HEAT mode, if the controlling temperature falls below the heating set point minus L.H.ON, then HVAC mode = LOW HEAT. To enter into a HIGH HEAT mode, if the controlling temperature falls below the heating set point minus L.H.ON minus H.H.ON, then HVAC mode = HIGH HEAT. To get out of a LOW HEAT mode, the controlling temperature must rise above the heating set point minus L.H.ON plus L.H.OF. the "Heating Setpoint" L.H.ON L.H.OF L.H.OF/2 H.H.ON A48-7702 Fig. 9 — Heating Offsets Table 66 — Heat/Cool Set Point Offsets ITEM D.LV.T L.H.ON H.H.ON L.H.OF L.C.ON H.C.ON L.C.OF C.T.LV H.T.LV C.T.TM H.T.TM EXPANSION COOL/HEAT SETPT. OFFSETS Dmd Level Lo Heat On Dmd Level(+) Hi Heat On Dmd Level(-) Lo Heat Off Dmd Level Lo Cool On Dmd Level(+) Hi Cool On Dmd Level(-) Lo Cool Off Cool Trend Demand Level Heat Trend Demand Level Cool Trend Time Heat Trend Time RANGE -1 - 2 0.5 - 20.0 0.5 - 2 -1 - 2 0.5 - 20.0 0.5 - 2 0.1 - 5 0.1 - 5 30 - 600 30 - 600 52 UNITS ^F ^F ^F ^F ^F ^F ^F ^F sec sec CCN POINT DMDLHON DMDHHON DMDLHOFF DMDLCON DMDHCON DMDLCOFF CTRENDLV HTRENDLV CTRENDTM HTRENDTM DEFAULT 1.5 0.5 1 1.5 0.5 1 0.1 0.1 120 120 Heat Control Prop. Gain (HT.P) — This configuration is the proportional term for the PID which runs in the HVAC mode LOW HEAT. Heat Control Derv. Gain (HT.D) — This configuration is the derivative term for the PID which runs in the HVAC mode LOW HEAT. Heat PID Rate Config (HT.TM) — This configuration is the PID run time rate. Staged Gas Heating Logic If the HVAC mode is HIGH HEAT: • The supply fan for staged gas heating is controlled by the integrated gas control (IGC) boards and, unless the supply fan is on for a different reason, it will be controlled by the IGC indoor fan input. • Command all stages of heat ON If the HVAC mode is LOW HEAT: • The supply fan for staged gas heating is controlled by the integrated gas control (IGC) boards and, unless the supply fan is on for a different reason, it will be controlled by the IGC indoor fan input. • The unit will control stages of heat to the heating control point (Run StatusVIEWHT.C.P). The heating control point in a LOW HEAT HVAC mode for staged gas is the heating supply air set point (SetpointsSA.HT). Staged Gas Heating PID Logic — The heat control loop is a PID (proportional/integral/derivative) design with exceptions, overrides, and clamps. Capacity rises and falls based on set point and supply-air temperature. When the staged gas control is in Low Heat or Tempering Mode (HVAC mode), the algorithm calculates the desired heat capacity. The basic factors that govern the controlling method are: • how fast the algorithm is run. • the amount of proportional and derivative gain applied. • the maximum allowed capacity change each time this algorithm is run. • deadband hold-off range when rate is low. This routine is run once every HT.TM seconds. Every time the routine is run, the calculated sum is added to the control output value. In this manner, integral effect is achieved. Every time this algorithm is run, the following calculation is performed: Error = HT.C.P – LAT Error_last = error calculated previous time P = HT.P*(Error) D = HT.D*(Error - Error_last) The P and D terms are overridden to zero if: Error < S.G.DB AND Error > - S.G.DB AND D < M.R.DB AND D > - M.R.DB. “P + D” are then clamped based on CAP.M. This sum can be no larger or no smaller than +CAP.M or –CAP.M. Finally, the desired capacity is calculated: Staged Gas Capacity Calculation = “P + D” + old Staged Gas Capacity Calculation NOTE: The PID values should not be modified without approval from Carrier. Table 67 — Mode Trip Helper Table ITEM TRIP UN.C.S UN.C.E OC.C.S OC.C.E TEMP OC.H.E OC.H.S UN.H.E UN.H.S HVAC EXPANSION MODE TRIP HELPER Unoccup. Cool Mode Start Unoccup. Cool Mode End Occupied Cool Mode Start Occupied Cool Mode End Ctl.Temp RAT,SPT or Zone Occupied Heat Mode End Occupied Heat Mode Start Unoccup. Heat Mode End Unoccup. Heat Mode Start the current HVAC MODE UNITS CCN POINT dF dF dF dF dF dF dF dF dF UCCLSTRT UCCL_END OCCLSTRT OCCL_END CTRLTEMP OCHT_END OCHTSTRT UCHT_END UCHTSTRT String If the HVAC mode is HIGH HEAT: • If Electric Heat is configured, then the control will request the supply fan ON • If Gas Heat is configured, then the IGC indoor fan input controls the supply fan request • The control will turn on Heat Relay 1 (HS1) • The control will turn on Heat Relay 2 (HS2) *The logic for this “low heat” override is that one stage of heating will not be able to raise the temperature of the supply airstream sufficient to heat the space. HT.CF = 3 (Staged Gas Heating Control) — As an option, the units with gas heat can be equipped with staged gas heat controls that will provide from 5 to 11 stages of heat capacity. This is intended for tempering mode and tempering economizer air when in a cooling mode and the dampers are fully closed. Tempering can also be used during a preoccupancy purge to prevent low temperature air from being delivered to the space. Tempering for staged gas will be discussed in its own section. This section will focus on heat mode control, which ultimately is relevant to tempering, minus the consideration of the supply air heating control point. The staged gas configurations are located at the local display under ConfigurationHEATSG.CF. See Table 68. Staged Gas Heat Type (HT.ST) — This configuration sets the number of stages and the order that are they staged. Max Cap Change per Cycle (CAP.M) — This configuration limits the maximum change in capacity per PID run time cycle. S.Gas DB Min.dF/PID Rate (M.R.DB) — This configuration is a deadband minimum temperature per second rate. See Staged Gas Heating logic below for more details. St.Gas Temp.Dead Band (S.G.DB) — This configuration is a deadband delta temperature. See Staged Gas Heating logic below for more details. Heat Rise in dF/Sec Clamp (RISE) — This configuration prevents the heat from staging up when the leaving-air temperature is rising too fast. LAT Limit Config (LAT.L) — This configuration senses when leaving-air temperature is outside a delta temperature band around set point and allows staging to react quicker. Limit Switch Monitoring? (LIM.M) — This configuration allows the operation of the limit switch monitoring routine. This should be set to NO as a limit switch temperature sensor is not used with A Series units. Limit Switch High Temp (SW.H.T) — This configuration is the temperature limit above which stages of heat will be removed. Limit Switch Low Temp (SW.L.T) — This configuration is the temperature limit above which no additional stages of heat will be allowed. IMPORTANT: When gas or electric heat is used in a VAV application with third party terminals, the HIR relay output must be connected to the VAV terminals in the system in order to enforce a minimum heating airflow rate. The installer is responsible to ensure the total minimum heating cfm is not below limits set for the equipment. Failure to do so will result in limit switch tripping and may void warranty. 53 Table 68 — Staged Gas Configuration ITEM EXPANSION SG.CF STAGED GAS CONFIGS HT.ST Staged Gas Heat Type CAP.M Max Cap Change per Cycle M.R.DB S.Gas DB min.dF/PID Rate S.G.DB St.Gas Temp. Dead Band RISE Heat Rise dF/sec Clamp LAT.L LAT Limit Config LIM.M Limit Switch Monitoring? SW.H.T Limit Switch High Temp SW.L.T Limit Switch Low Temp HT.P Heat Control Prop. Gain HT.D Heat Control Derv. Gain HT.TM Heat PID Rate Config *Some configurations are model number dependent. RANGE 0-4 5 - 45 0-5 0-5 0.05 - 0.2 0 - 20 Yes/No 110 - 180 100 - 170 0 - 1.5 0 - 1.5 60 - 300 UNITS ^F ^F dF dF sec CCN POINT HTSTGTYP HTCAPMAX HT_MR_DB HT_SG_DB HTSGRISE HTLATLIM HTLIMMON HT_LIMHI HT_LIMLO HT_PGAIN HT_DGAIN HTSGPIDR DEFAULTS 0* 45* 0.5 2 0.06 10 Yes 170* 160* 1 1 90 there will be one IGC board. On size 020-050 high heat units and 051 and 060 low heat units there are two IGC boards. On size 051 and 060 high heat units there are three IGC boards. When a call for gas heat is initiated, power is sent to W on the IGC boards. For standard 2-stage heat, all boards are wired in parallel. For staged gas heat, each board is controlled separately. When energized, an LED on the IGC board will be turned on. See Table 74 for LED explanations. Each board will ensure that the rollout switch and limit switch are closed. The induced-draft motor is then energized. When the speed of the motor is proven with the Hall Effect sensor on the motor, the ignition activation period begins. The burners ignite within 5 seconds. If the burners do not light, there is a 22-second delay before another 5-second attempt is made. If the burners still do not light, this sequence is repeated for 15 minutes. After 15 minutes have elapsed and the burners have not ignited then heating is locked out. The control will reset when the request for W (heat) is temporarily removed. When ignition occurs, the IGC board will continue to monitor the condition of the rollout switch, limit switches, Hall Effect sensor, and the flame sensor. Forty-five seconds after ignition has occurred, the IGC will request that the indoor fan be turned on. The IGC fan output (IFO) is connected to the indoor fan input on the MBB which will indicate to the controls that the indoor fan should be turned on (if not already on). If for some reason the overtemperature limit switch trips prior to the start of the indoor fan blower, on the next attempt the 45-second delay will be shortened by 5 seconds. Gas will not be interrupted to the burners and heating will continue. Once modified, the fan delay will not change back to 45 seconds unless power is reset to the control. The IGC boards only control the first stage of gas heat on each gas valve. The second stages are controlled directly from the MBB board. The IGC board has a minimum on-time of 1 minute. In modes such as Service Test where long minimum on times are not enforced, the 1-minute timer on the IGC will still be followed and the gas will remain on for a minimum of 1 minute. Staged Gas Heat Staging — Different unit sizes will control heat stages differently based on the amount of heating capacity included. These staging patterns are selected based on the model number. The selection of a set of staging patterns is controlled via the heat stage type configuration parameter (HT.ST). As the heating capacity rises and falls based on demand, the staged gas control logic will stage the heat relay patterns up and down, respectively. The Heat Stage Type configuration selects one of 4 staging patterns that the stage gas control will use. In addition to the staging patterns, the capacity for each stage is also determined by the staged gas heating PID control. Therefore, choosing the heat relay outputs is a function of the capacity desired, the heat staging patterns based on the heat stage type (HT.ST) and the capacity presented by each staging pattern. As the staged gas control desired capacity rises, it is continually checked against the capacity of the next staging pattern. When the desired capacity is greater than or equal to the capacity of the next staging pattern, the next heat stage is selected (Run StatusVIEWHT.ST = Run StatusVIEW HT.ST + 1). Similarly, as the capacity of the control drops, the desired capacity is continually checked against the next lower stage. When the desired capacity is less than or equal to the next lower staging pattern, the next lower heat stage pattern is selected (Run StatusVIEWHT.ST = Run StatusVIEW HT.ST - 1). The first two staged gas heat outputs are located on the MBB board and outputs 3, 4, 5, and 6 are located on the SCB board. These outputs are used to produce 5 to 11 stages as shown in Tables 69A and 69B. The heat stage selected (Run StatusVIEWHT.ST) is clamped between 0 and the maximum number of stages possible (Run StatusVIEWH.MAX) for the chosen set of staging patterns. See Tables 70-73. INTEGRATED GAS CONTROL BOARD LOGIC — All gas heat units are equipped with one or more integrated gas control (IGC) boards. This board provides control for the ignition system for the gas heat sections. On size 020-050 low heat units Table 69A — Staged Gas Heat — 48AJ,AK,AW,AY Units UNIT SIZE 020-035 036-050 051,060 HEAT CAPACITY Low High Low High Low High UNIT MODEL NO. POSITION NO. 5 S T S T S T 54 ConfigurationHEATSG.CFHT.ST ENTRY VALUE 1 = 5 STAGE 2 = 7 STAGE 1 = 5 STAGE 1 = 5 STAGE 4 = 11 STAGE 3 = 9 STAGE Table 69B — Staged Gas Heat — 48A2,A3,A4,A5 Units UNIT SIZE HEAT CAPACITY Low High Low High Low High 020-030 035-050 060 UNIT MODEL NO. POSITION NO. 5 S T S T S T ConfigurationHEATSG.CF HT.ST ENTRY VALUE 1 = 5 STAGE 2 = 7 STAGE 1 = 5 STAGE 1 = 5 STAGE 4 = 11 STAGE 3 = 9 STAGE Table 70 — Staged Gas Heat Control Steps (ConfigurationHEATSG.CFHT.ST = 1) STAGE 0 1 2 3 4 5 Heat 1 MBB-RLY8 IGC1 OFF ON ON ON ON ON Heat 2 MBB-RLY7 MGV1 OFF OFF ON OFF ON ON RELAY OUTPUT Heat 3 Heat 4 SCB-RLY1 SCB-RLY2 IGC2 MGV2 OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON ON Heat 5 SCB-RLY3 IGC3 OFF OFF OFF OFF OFF OFF Heat 6 SCB-RLY4 MGV3 OFF OFF OFF OFF OFF OFF CAPACITY % 0 37 50 75 87 100 Table 71 — Staged Gas Heat Control Steps (ConfigurationHEAT SG.CTHT.ST = 2) STAGE 0 1 2 3 4 5 6 7 Heat 1 MBB-RLY8 IGC1 OFF ON ON OFF OFF ON ON ON Heat 2 MBB-RLY7 MGV1 OFF OFF ON OFF OFF OFF ON ON RELAY OUTPUT Heat 3 Heat 4 SCB-RLY1 SCB-RLY2 IGC2 MGV2 OFF OFF OFF OFF OFF OFF ON OFF ON ON ON OFF ON OFF ON ON Heat 5 SCB-RLY3 IGC3 OFF OFF OFF OFF OFF OFF OFF OFF Heat 6 SCB-RLY4 MGV3 OFF OFF OFF OFF OFF OFF OFF OFF CAPACITY % 0 25 33 50 67 75 83 100 Table 72 — Staged Gas Heat Control Steps (ConfigurationHEAT SG.CTHT.ST = 3) STAGE 0 1 2 3 4 5 6 7 8 9 Heat 1 MBB-RLY8 IGC1 OFF ON ON ON ON ON ON ON ON ON Heat 2 MBB-RLY7 MGV1 OFF OFF ON OFF ON ON OFF OFF ON ON RELAY OUTPUT Heat 3 Heat 4 SCB-RLY1 SCB-RLY2 IGC2 MGV2 OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON ON ON OFF ON ON ON ON ON ON 55 Heat 5 SCB-RLY3 IGC3 OFF OFF OFF OFF OFF OFF ON ON ON ON Heat 6 SCB-RLY4 MGV3 OFF OFF OFF OFF OFF OFF OFF OFF OFF ON CAPACITY % 0 25 33 50 58 67 75 83 92 100 Table 73 — Staged Gas Heat Control Steps (ConfigurationHEAT SG.CTHT.ST = 4) Heat 1 MBB-RLY8 IGC1 OFF ON ON ON ON ON ON ON ON ON ON ON STAGE 0 1 2 3 4 5 6 7 8 9 10 11 Heat 2 MBB-RLY7 MGV1 OFF OFF ON OFF ON ON OFF ON OFF OFF ON ON RELAY OUTPUT Heat 3 Heat 4 SCB-RLY1 SCB-RLY2 IGC2 MGV2 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF ON ON ON ON ON ON Heat 6 SCB-RLY4 MGV3 OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF ON CAPACITY % 0 19 25 38 44 50 57 63 76 88 94 100 end inside the unit control box at the factory leads from MBB J8 terminals 11 and 12 (PNK) leads. Secure the unattached PNK leads from the factory harness to ensure no accidental contact with other terminals inside the control box. MORNING WARM UP — Morning Warm Up is a period of time that assists CCN linkage in opening up downstream zone dampers for the first heating cycle of a day. The Morning Warm Up Period is CCN linkage mode “2” and is relayed in the following conditions: • Temperature Compensated Start Mode is active AND Heat Mode in effect AND LAT is warm enough or is to be ignored due to placement. • The unit just went into occupied mode and there has been no cooling mode yet and a heat cycle occurs or was in progress when the unit went occupied. In both cases, if and when the heat mode terminates, a heat cycle has occurred and any subsequent heat cycles will not be treated as a morning warm up period. TEMPERING MODE — In a vent or cooling mode, the rooftop may encounter a situation where the economizer at minimum position is sending cold outside air down the ductwork of the building. Therefore, it may be necessary to bring heat on to counter-effect this low supply-air temperature. This is referred to as the tempering mode. Setting up the System — The relevant set points for Tempering are located at the local display under Setpoints: RELOCATE SAT (Supply Air Temperature) SENSOR FOR HEATING IN LINKAGE APPLICATIONS — On CCN installations employing ComfortID™ terminals, the factory SAT location must be changed to a new location downstream of the unit’s heating system. The ComfortID terminal controls read the SAT value for their “proof-of-heat” sequence before terminals open to Minimum Heating positions during unit heating sequence. Determine a location in the supply duct that will provide a fairly uniform airflow. Typically this would be a minimum of 5 equivalent duct diameters downstream of the unit. Also, care should be taken to avoid placing the thermistor within a direct line-of-sight of the heating element to avoid radiant effects. Run a new two-wire conductor cable from the control box through the low voltage conduit into the space inside the building and route the cable to the new sensor location. Installing a New Sensor — A field-provided duct-mount temperature sensor (Carrier P/N 33ZCSENPAT or equivalent 10 kilo-ohm at 25 C NTC [negative temperature coefficient] sensor) is required. Install the sensor through the side wall of the duct and secure. Table 74 — IGC LED Indicators LED INDICATION On Off 1 Flash 2 Flashes 3 Flashes 4 Flashes 5 Flashes 6 Flashes 7 Flashes 8 Flashes 9 Flashes Heat 5 SCB-RLY3 IGC3 OFF OFF OFF ON ON ON OFF OFF ON ON ON ON ERROR CODE Normal Operation Hardware Failure Fan On/Off Delay Modified Limit Switch Fault Fame Sense Fault Five Consecutive Limit Switch Faults Ignition Lockout Fault Ignition Switch Fault Rollout Switch Fault Internal Control Fault Software Lockout ITEM T.PRG T.CL T.V.OC T.V.UN NOTES: 1. There is a 3-second pause between error code displays. 2. If more than one error code exists, all applicable error codes will be displayed in numerical sequence. 3. Error codes on the IGC will be lost if power to the unit is interrupted. EXPANSION Tempering Purge SASP Tempering in Cool SASP Tempering Vent Occ SASP Tempering Vent Unocc. SASP –20-80 dF CCN DEFAULT POINT TEMPPURG 50 5-75 dF TEMPCOOL 5 –20-80 dF TEMPVOCC 65 –20-80 dF TEMPVUNC 50 RANGE UNITS Operation — First, the unit must be in a vent mode, a low cool mode, or a high cool HVAC mode to be considered for a tempering mode. Secondly, the tempering mode is only allowed when the rooftop is configured for staged gas (Configuration HEATHT.CF=3). If the control is configured for staged gas, the control is in a vent, low cool, or high cool HVAC mode, and the rooftop control is in a situation where the economizer must maintain a minimum position, then the evaporator discharge temperature (EDT) will be monitored. If the EDT falls below a particular trip point then the tempering mode may be called out: HVAC mode = “Tempering Vent” Re-Using the Factory SAT Sensor — The factory sensor is attached to one of the supply fan housings. Disconnect the sensor from the factory harness. Drill a hole insert the sensor through the duct wall and secure in place. Attach the new conductor cable to the sensor leads and terminate in an appropriate junction box. Connect the opposite 56 pressure and calculates the error from set point. This error is simply the duct static pressure set point minus the measured duct static pressure. The error becomes the basis for the proportional term of the PID. The routine also calculates the integral of the error over time, and the derivative (rate of change) of the error. A value is calculated as a result of this PID routine, and this value is then used to create an output signal used to adjust the VFD to maintain the static pressure set point. Static pressure reset is the ability to force a lowering of the static pressure set point through an external control signal. The unit controls support this in two separate ways, through a 4 to 20 mA signal input wired to the unit’s isolator board input terminals (third party control) or via CCN. When employing the CCN, this feature uses the communications capabilities of VAV systems with ComfortID™ terminals under linkage. The system dynamically determines and maintains an optimal duct static pressure set point based on the actual load conditions in the space. This can result in a significant reduction in required fan energy by lowering the set point to only the level required to maintain adequate airflow throughout the system. SETTING UP THE SYSTEM — The options for static pressure control are found under the Local Display Mode ConfigurationSP. See Table 75. HVAC mode = “Tempering LoCool” HVAC mode = “Tempering HiCool” The decision making/selection process for the tempering trip set point is as follows: • If an HVAC cool mode is in effect, then the vent trip point is T.CL. • If in a pre-occupied purge mode (Operating Modes MODEIAQ.P=ON), then the trip point is T.PRG. • If in an occupied mode (Operating ModesMODE IAQ.P=ON), then the trip point is T.V.OC. • For all other cases, the trip point is T.V.UN. NOTE: The unoccupied economizer free cooling mode does not qualify as a HVAC cool mode as it is an energy saving feature and has its own OAT lockout already. The unoccupied free cooling mode (HVAC mode = Unocc. Free Cool) will override any unoccupied vent mode from triggering a tempering mode. If OAT is above the chosen tempering set point, tempering will not be allowed. Additionally, tempering mode is locked out if any stages of mechanical cooling are present. A minimum amount of time must pass before calling out any tempering mode. In effect, the EDT must fall below the trip point value –1° F continuously for a minimum of 2 minutes. Also, at the end of a mechanical cooling cycle, there must be a minimum 10 minutes of delay allowed before considering tempering during vent mode in order to allow any residual cooling to dissipate from the evaporator coil. If the above conditions are met, the algorithm is free to select the tempering mode (MODETEMP). If a tempering mode becomes active, the modulating heat source (staged gas) will attempt to maintain leaving-air temperature (LAT) at the tempering set point used to trigger the tempering mode. The technique for modulation of set point for staged gas and hydronic heat is the same as in a heat mode. More information regarding the operation of heating can be referenced in the Heating Control section. Recovery from a tempering mode (MODETEMP) will occur when the EDT rises above the trip point. On any change in HVACMODE, the tempering routine will re-assess the tempering set point which may cause the control to continue or exit tempering mode. CAUTION Failure to correctly configure SP.CF and SP.FN when operating in VFD Bypass mode will result in the indoor fan motor running continuously. Damage to unit could result. Static Pressure Configuration (SP.CF) — This variable is used to configure the use of ComfortLink™ controls for static pressure control. There are the following options: 0 (None) — There will be no static pressure control by ComfortLink controls. This setting would be used for a constant volume (CV) application when static pressure control is not required or for a VAV application if there will be third-party control of the VFD. In this latter case, a suitable means of control must be field installed. Additionally, SP.CF must be set to 0 (None) when a unit is equipped with optional VFD bypass and is operating in Bypass mode. Failure to change this configuration in Bypass mode will result in the indoor fan motor running continuously. 1 (VFD Control) — This will enable the use of ComfortLink controls for static pressure control via a supply fan VFD. Static Pressure Fan Control? (SP.FN) — This is automatically set to Yes when SP.CF = 1. When the user would like the 4 to 20 mA output to energize the VFD, as opposed to the fan relay, SP.FN may be set to Yes when SP.CF = 0. When the control turns the fan ON, the control will send the SP.MX value of the 4 to 20 mA signal to the third party VFD control. Additionally, SP.FN must be set to NO when the unit is equipped with optional VFD bypass and is operating in Bypass mode. Failure to change this configuration in bypass mode will result in the indoor fan motor running continuously. Static Pressure Sensor (SP.S) — This variable enables the use of a supply duct static pressure sensor. This must be enabled to use ComfortLink controls for static pressure control. If using a third-party control for the VFD, this should be disabled. Static Pressure Low Range (SP.LO) — This is the minimum static pressure that the sensor will measure. For most sensors this will be 0 in. wg. The ComfortLink controls will map this value to a 4 mA sensor input. Static Pressure High Range (SP.HI) — This is the maximum static pressure that the sensor will measure. Commonly this will be 5 in. wg. The ComfortLink controls will map this value to a 20 mA sensor input. Static Pressure Control — Variable air volume (VAV) air-conditioning systems must provide varying amounts of air to the conditioned space. As air terminals downstream of the unit modulate their flows, the unit must maintain control over the duct static pressure in order to accommodate the needs of the terminals and meet the varying combined airflow requirement. A 48/50AK,AY,A3,A5 unit equipped with a duct pressure control system is provided with a variable frequency drive (VFD) for the supply fan. The speed of the fan can be controlled directly by the ComfortLink™ controls. A transducer is used to measure duct static pressure. The signal from the transducer is received by the ECB-2 board and is then used in a PID control routine that outputs a 4 to 20 mA signal to the VFD. Generally, only VAV systems utilize static pressure control. It is required because as the system VAV terminals modulate closed when less air is required, there must be a means of controlling airflow from the unit, thereby effectively preventing overpressurization and its accompanying problems. The three most fundamental configurations for most applications are ConfigurationSPSP.CF, which is the static pressure control type, ConfigurationSPSP.S, used to enable the static pressure sensor, and ConfigurationSP SP.SP, the static pressure set point to be maintained. OPERATION — On units equipped with a VFD and a proper static pressure sensor, when SP.CF, SP.S and SP.SP are configured, a PID routine periodically measures the duct static 57 directly to the 0 to 3 in. wg of reset. Therefore 2 mA reset is 2/16 * 3 in. wg = 0.375 in. wg of reset. If the static pressure set point (SP.SP) = 1.5 in. wg, then the static pressure control point for the system will be reset to 1.5 – 0.375 = 1.125 in. wg. When SP.RS = 4, the static pressure reset function acts to provide direct VFD speed control where 4 mA = 0% speed and 20 mA = 100% (SP.MN and SP.MX will override). Note that SP.CF must be set to 1 (VFD Control), prior to configuring SP.RS = 4. Failure to do so could result in damage to ductwork due to overpressurization. This is the recommended approach if a third party wishes to control the variable speed supply fan. In effect, this represents a speed control signal “pass through” under normal operating circumstances. The ComfortLink control system overrides the third party signal for critical operation situations, most notably smoke and fire control. Static Pressure Reset Ratio (SP.RT) — This option defines the reset ratio in terms of static pressure versus temperature. The reset ratio determines how much is the static pressure reduced for every degree below set point for RAT or SPT. Static Pressure Reset Limit (SP.LM) — This option defines the maximum amount of static pressure reset that is allowed. This is sometimes called a “clamp.” NOTE: Resetting static pressure via RAT and SPT is primarily a constant volume application which utilizes a VFD. The reasoning is that there is significant energy savings in slowing down a supply fan as opposed to running full speed with supply air reset. Maintaining the supply air set point and slowing down the fan has the additional benefit of working around dehumidification concerns. Static Pressure Reset Economizer Position (SP.EC) — This option effectively resets ECONOMIN to fully occupied ventilation position, to account for the drop in static pressure during static pressure reset control. The static pressure reset for the calculation cannot be larger than the supply air static set point (SPSP). The calculation is as follows: (Static Pressure Reset/SP.LM) x (ECONOSPR – ECONOMIN) As an example, the static pressure reset limit (SP.LM) = 0.75 in. wg. The current static pressure reset is set to 0.5 in. wg. The settings for ECONOSPR = 50% and ECONOMIN = 20%. Static Pressure Set Point (SP.SP) — This is the static pressure control point. It is the point against which the ComfortLink controls compare the actual measured supply duct pressure for determination of the error that is used for PID control. Generally one would set SP.SP to the minimum value necessary for proper operation of air terminals in the conditioned space at all load conditions. Too high of a value will cause unnecessary fan motor power consumption at part-load conditions and/or noise problems. Too low a value will result in insufficient airflow. VFD Minimum Speed (SP.MN) — This is the minimum speed for the supply fan VFD. Typically the value is chosen to maintain a minimum level of ventilation. NOTE: Most VFDs have a built-in minimum speed adjustment which must be configured for 0% when using ComfortLink controls for static pressure control. VFD Maximum Speed (SP.MX) — This is the maximum speed for the supply fan VFD. This is usually set to 100%. VFD Fire Speed Override (SP.FS) — This is the speed that the supply fan VFD will use during the pressurization, evacuation and purge fire modes. This is usually set to 100%. Static Pressure Reset Configuration (SP.RS) — This option is used to configure the static pressure reset function. When SP.RS = 0, there is no static pressure reset via an analog input. If the outdoor air quality sensor is not configured (ConfigurationIAQIAQ.CFOQ.A.C = 0), then it is possible to use the outdoor air quality sensor location on the CEM board to perform static pressure reset via an external 4 to 20 mA input. Configuring SP.RS = 1 provides static pressure reset based on this CEM 4 to 20 mA input and ranged from 0 to 3 in. wg. Wire the input to the CEM using TB6-11 and 12. When SP.RS = 2, there is static pressure reset based on RAT and defined by SP.RT and SP.LM. When SP.RS = 3, there is static pressure reset based on SPT and defined by SP.RT and SP.LM. Setting SP.RS to 1, 2 or 3 will give the user the ability to reset from 0 to 3 in. wg of static pressure. The reset will apply to the supply static pressure set point. The static pressure reset function will only act to reduce the static pressure control point. As an example, the static pressure reset input is measuring 6 mA, and is therefore resetting 2 mA (6 mA – 4 mA) of its 16 mA control range. The 4 to 20 mA range corresponds Table 75 — Static Pressure Control Configuration ITEM SP SP.CF SP.FN SP.S SP.LO SP.HI SP.SP SP.MN SP.MX SP.FS SP.RS SP.RT SP.LM SP.EC S.PID SP.TM SP.P SP.I SP.D SP.SG EXPANSION SUPPLY STATIC PRESS.CFG. Static Pres. VFD Control? Static Pres. Fan Control? Static Pressure Sensor Static Press. Low Range Static Press. High Range Static Pressure Setpoint VFD Minimum Speed VFD Maximum Speed VFD Fire Speed Override Stat. Pres. Reset Config SP Reset Ratio (/dF) SP Reset Limit in iwc () SP Reset Econo.Position STAT.PRESS.PID CONFIGS Static Press. PID Run Rate Static Press. Prop. Gain Static Press. Intg. Gain Static Press. Derv. Gain Static Press. System Gain RANGE 0, 1 Yes/No Enable/Disable –10 - 0 0 - 10 0-5 0 - 100 0 - 100 0 - 100 0-4 0 - 2.00 0 - 2.00 0 - 100 1 - 200 0 - 100 0 - 50 0 - 50 0 - 50 *Some defaults are model number dependent. 58 UNITS in. W.C. in. W.C. in. W.C. % % % % sec CCN POINT DEFAULT STATICFG STATPFAN SPSENS SP_LOW SP_HIGH SPSP STATPMIN STATPMAX STATPFSO SPRSTCFG SPRRATIO SPRLIMIT ECONOSPR 0* Yes* Disable* 0 5 1.5 20 100 100 0 0.2 0.75 5 SPIDRATE STATP_PG STATP_IG STATP_DG STATP_SG 2 20 2 0 1.0 case, the installer could enter 3.0 in. wg as the supply static pressure set point and allow the air terminal system to dynamically adjust the supply duct static pressure set point as required. The system will determine the actual set point required delivering the required airflow at every terminal under the current load conditions. The set point will always be the lowest value under the given conditions. As the conditions and airflow set points at each terminal change throughout the operating period, the equipment static pressure set point will also change. The CCN system must have access to a CCN variable (SPRESET which is part of the equipment controller). In the algorithm for static pressure control, the SPRESET value is always subtracted from the configured static pressure set point by the equipment controller. The SPRESET variable is always checked to be a positive value or zero only (negative values are limited to zero). The result of the subtraction of the SPRESET variable from the configured set point is limited so that it cannot be less than zero. The result is that the system will dynamically determine the required duct static pressure based on the actual load conditions currently in the space. This eliminates the need to calculate the design supply static pressure set point. This also saves the energy difference between the design static pressure set point and the required static pressure. Third Party 4 to 20 mA Input — It is also possible to perform static pressure reset via an external 4 to 20 mA signal connected to the CEM board where 4 mA corresponds to 0 in. wg of reset and 20 mA corresponds to 3 in. wg of reset. The static pressure 4 to 20 mA input shares the same input as the analog OAQ sensor. Therefore, both sensors cannot be used at the same time. To enable the static pressure reset 4 to 20 mA sensor, set (ConfigurationSPSP.RS) to Enabled. RELATED POINTS — These points represent static pressure control and static pressure reset inputs and outputs. See Table 76. Static Pressure mA (SP.M) — This variable reflects the value of the static pressure sensor signal received by the ComfortLink™ controls. The value may be helpful in troubleshooting. Static Pressure mA Trim (SP.M.T) — This input allows a modest amount of trim to the 4 to 20 mA static pressure transducer signal, and can be used to calibrate a transducer. Static Pressure Reset mA (SP.R.M) — This input reflects the value of a 4 to 20 mA static pressure reset signal applied to TB6 terminals 11 and 12 on the CEM board, from a third party control system. Static Pressure Reset (SP.RS) — This variable reflects the value of a static pressure reset signal applied from a CCN system. The means of applying this reset is by forcing the value of the variable SPRESET through CCN. Supply Fan VFD Speed (S.VFD) — This output can be used to check on the actual speed of the VFD. This may be helpful in some cases for troubleshooting. Therefore, the amount to add to the economizer’s ECONOMIN configuration is: (0.5/0.75) x (50-20) = 20%. In effect, for the positioning of the economizer, ECONOMIN would now be replaced by ECONOMIN + 10%. Static Pressure PID Config (S.PID) — Static pressure PID configuration can be accessed under this heading in the ConfigurationSP submenu. Under most operating conditions the control PID factors will not require any adjustment and the factory defaults should be used. If persistent static pressure fluctuations are detected, small changes to these factors may improve performance. Decreasing the factors generally reduce the responsiveness of the control loop, while increasing the factors increase its responsiveness. Note the existing settings before making changes, and seek technical assistance from Carrier before making significant changes to these factors. Static Pressure PID Run Rate (S.PIDSP.TM) — This is the number of seconds between duct static pressure readings taken by the ComfortLink™ PID routine. Static Pressure Proportional Gain (S.PIDSP.P) — This is the proportional gain for the static pressure control PID control loop. Static Pressure Integral Gain (S.PIDSP.I) — This is the integral gain for the static pressure control PID control loop. Static Pressure Derivative Gain (S.PIDSP.D) — This is the derivative gain for the static pressure control PID control loop. Static Pressure System Gain (S.PIDSP.SG) — This is the system gain for the static pressure control PID control loop. STATIC PRESSURE RESET OPERATION — The ComfortLink controls support the use of static pressure reset. The Linkage Master terminal monitors the primary air damper position of all the terminals in the system (done through LINKAGE with the new ComfortID™ air terminals). The Linkage Master then calculates the amount of supply static pressure reduction necessary to cause the most open damper in the system to open more than the minimum value (60%) but not more than the maximum value (90% or negligible static pressure drop). This is a dynamic calculation, which occurs every two minutes when ever the system is operating. The calculation ensures that the supply static pressure is always enough to supply the required airflow at the worst case terminal but never more than necessary, so that the primary air dampers do not have to operate with an excessive pressure drop (more than required to maintain the airflow set point of each individual terminal in the system). As the system operates, if the most open damper opens more than 90%, the system recalculates the pressure reduction variable and the value is reduced. Because the reset value is subtracted from the controlling set point at the equipment, the pressure set point increases and the primary-air dampers close a little (to less than 90%). If the most open damper closes to less than 60%, the system recalculates the pressure reduction variable and the value is increased. This results in a decrease in the controlling set point at the equipment, which causes the primary-air dampers to open a little more (to greater than 60%). The rooftop unit has the static pressure set point programmed into the CCN control. This is the maximum set point that could ever be achieved under any condition. To simplify the installation and commissioning process for the field, this system control is designed so that the installer only needs to enter a maximum duct design pressure or maximum equipment pressure, whichever is less. There is no longer a need to calculate the worst case pressure drop at design conditions and then hope that some intermediate condition does not require a higher supply static pressure to meet the load conditions. For example, a system design requirement may be 1.2 in. wg, the equipment may be capable of providing 3.0 in. wg and the supply duct is designed for 5.0 in. wg. In this Fan Status Monitoring GENERAL — The A Series ComfortLink controls offer the capability to detect a failed supply fan through either a duct static pressure transducer or an accessory discrete switch. The fan status switch is an accessory that allows for the monitoring of a discrete switch, which trips above a differential pressure drop across the supply fan. For any unit with a factory-installed duct static pressure sensor, it is possible to measure duct pressure rise directly, which removes the need for a differential switch. All 48/50AK,AW,A3,A5 units with a factory-installed supply fan VFD will have the duct static pressure sensor as standard. SETTING UP THE SYSTEM — The fan status monitoring configurations are located in ConfigurationUNIT. See Table 77. 59 Table 76 — Static Pressure Reset Related Points ITEM Inputs 4-20 SP.M 4-20 SP.M.T 4-20 SP.R.M RSET SP.RS Outputs Fans S.VFD EXPANSION RANGE 4-20 -2.0 - +2.0 4-20 0.0-3.0 mA mA mA in. wg SP_MA SPMATRIM SPRST_MA SPRESET Supply Fan VFD Speed 0-100 % SFAN_VFD EXPANSION RANGE Fan Fail Shuts Down Unit Yes/No Fan Stat Monitoring Type 0 - 2 CCN POINT SFS_SHUT SFS_MON the outside and return air dampers of the unit to provide ventilation air as well as free cooling based on several configuration options. This section contains a description of the economizer and its ability to provide free cooling. See the section on Indoor Air Quality Control on page 67 for more information on setting up and using the economizer to perform demand controlled ventilation (DCV). See the Third Party Control section for a description on how to take over the operation of the economizer through external control. The economizer system also permits this unit to perform smoke control functions based on external control switch inputs. Refer to the Smoke Control Modes section for detailed discussions. Economizer control can be based on automatic control algorithms using unit-based set points and sensor inputs. This economizer control system can also be managed through external logic systems. The economizer system is a factory-installed option. This unit can also have the following devices installed to enhance economizer control: • Outside air humidity sensor • Return air humidity sensor NOTE: All these options require the controls expansion module (CEM). SETTING UP THE SYSTEM — The economizer configuration options are under the Local Display Mode Configuration ECON. See Table 79. Economizer Installed? (EC.EN) — If an economizer is not installed or is to be completely disabled then the configuration option EC.EN should be set to No. Otherwise in the case of an installed economizer, this value must be set to Yes. Economizer Minimum Position (EC.MN) — The configuration option EC.MN is the economizer minimum position. See the section on indoor air quality for further information on how to reset the economizer further to gain energy savings and to more carefully monitor IAQ problems. Economizer Maximum Position (EC.MX) — The upper limit of the economizer may be limited by setting EC.MX. This value defaults to 98% to avoid problems associated with slight changes in the economizer damper’s end stop over time. Typically this will not need to be adjusted. Economizer Trim for Sum Z? (E.TRM) — Sum Z is the adaptive cooling control algorithm used for multiple stages of mechanical cooling capacity. The configuration option, E.TRM is typically set to Yes, and allows the economizer to field-installed accessory dirty filter switch. The switch is located in the filter section. If a dirty filter switch is not installed, the switch input is configured to read “clean” all the time. To enable the sensor for dirty filter monitoring set ConfigurationUNITSENSFLT.S to ENABLE. The state of the filter status switch can be read at InputsGEN.I FLT.S. See Table 78. Table 78 — Dirty Filter Switch Points ConfigurationUNIT SENSFLT.S InputsGEN.I FLT.S RANGE 0.0 0.0 Economizer — The economizer control is used to manage Dirty Filter Switch — The unit can be equipped with a EXPANSION DEFAULT Monitoring of the filter status switch is disabled in the Service Test mode and when the supply fan is not commanded on. If the fan is on and the unit is not in a test mode and the filter status switch reads “dirty” for 2 continuous minutes, an alert is generated. Recovery from this alert is done through a clearing of all alarms or after cleaning the filter and the switch reads “clean” for 30 seconds. NOTE: The filter switch should be adjusted to allow for the operating cfm and the type of filter. Refer to the accessory installation instructions for information on adjusting the switch. Fan Stat Monitoring Type (SFS.M) — This configuration selects the type of fan status monitoring to be performed. 0 - NONE — No switch or monitoring 1 - SWITCH — Use of the fan status switch 2 - SP RISE — Monitoring of the supply duct pressure. Fan Fail Shuts Down Unit (SFS.S) — This configuration will configure the unit to shut down on a supply fan status fail or simply alert the condition and continue to run. When configured to YES, the control will shut down the unit if supply fan status monitoring fails and the control will also send out an alarm. If set to NO, the control will not shut down the unit if supply fan status monitoring fails but will send out an alert. SUPPLY FAN STATUS MONITORING LOGIC — Regardless of whether the user is monitoring a discrete switch or is monitoring static pressure, the timing for both methods are the same and rely upon the configuration of static pressure control. The configuration that determines static pressure control is ConfigurationSPSP.CF. If this configuration is set to 0 (none), a fan failure condition must wait 60 continuous seconds before taking action. If this configuration is 1 (VFD), a fan failure condition must wait 3 continuous minutes before taking action. If the unit is configured to monitor a fan status switch (SFS.M = 1), and if the supply fan commanded state does not match the supply fan status switch for 3 continuous minutes, then a fan status failure has occurred. If the unit is configured for supply duct pressure monitoring (SFS.M = 2), then • If the supply fan is requested ON and the static pressure reading is not greater than 0.2 in. wg for 3 continuous minutes, a fan failure has occurred. • If the supply fan is requested OFF and the static pressure reading is not less than 0.2 in. wg for 3 continuous minutes, a fan failure has occurred. ITEM CCN POINT Static Pressure mA Static Pressure mA Trim Static Pressure Reset mA Static Pressure Reset Table 77 — Fan Status Monitoring Configuration ITEM SFS.S SFS.M UNITS CCN POINT FLTS_ENA Filter Enable/ Stat.Sw.Enabled ? Disable Filter Status Input DRTY/CLN FLTS 60 modulate to the same control point (Sum Z) that is used to control capacity staging. The advantage is lower compressor cycling coupled with tighter temperature control. Setting this option to No will cause the economizer, if it is able to provide free cooling, to open to the Economizer Max. Position (EC.MX) during mechanical cooling. ECONOMIZER OPERATION — There are four potential elements which are considered concurrently which determine whether the economizer is able to provide free cooling: 1. Dry bulb changeover (outside-air temperature qualification) 2. Economizer switch (discrete control input monitoring) 3. Economizer changeover select (E.SEL economizer changeover select configuration option) 4. Outdoor dewpoint limit check (requires an installed outdoor relative humidity sensor installed) Dry Bulb Changeover (OAT.L) — Outside-air temperature may be viewed under TemperaturesAIR.TOAT. The control constantly compares its outside-air temperature reading against the high temperature OAT lockout (OAT.L). If the temperature reads above OAT.L, the economizer will not be allowed to perform free cooling. Economizer Switch (EC.SW) — The function of this switch is determined by Configuration ECONEC.SW. The state of the corresponding economizer input can be viewed under InputsGEN.IE.SW. When set to EC.SW = 0, the switch is disabled. When set to EC.SW = 1, the economizer switch functions to enable/disable the economizer. When set to EC.SW = 2, the switch functions as an IAQ override switch. This functions just like the discrete IAQ input InputsAIR.QIAQ.I when Configuration IAQAQ.CFIQ.I.C=2 (IAQ Discrete Override). See the Indoor Air Quality Control section for more information. When ConfigurationECONEC.SW=1 and Inputs GEN.IE.SW = No, free cooling will not be allowed. Economizer Control Type (E.TYP) — This configuration should not be changed. Economizer Changeover Select (E.SEL) — The control is capable of performing any one of the following changeover types in addition to both the dry bulb lockout and the external switch enable input: E.SEL = 0 none E.SEL = 1 Differential Dry Bulb Changeover E.SEL = 2 Outdoor Enthalpy Changeover E.SEL = 3 Differential Enthalpy Changeover Differential Dry Bulb Changeover — As both return air and outside air temperature sensors are installed as standard on these units, the user may select this option, E.SEL = 1, to perform a qualification of return and outside air in the enabling and disabling of free cooling. If this option is selected and outside-air temperature is greater than return-air temperature, free cooling will not be allowed. Outdoor Enthalpy Changeover — This option should be used in climates with higher humidity conditions. The A Series control can use an enthalpy switch or enthalpy sensor, or the standard installed outdoor dry bulb sensor and an accessory relative humidity sensor to calculate the enthalpy of the air. Setting ConfigurationECONE.SEL = 2 requires that the user configure ConfigurationECONOA.E.C, the Outdoor Enthalpy Changeover Select, and install an outdoor relative humidity sensor. Once the sensor is installed, enable ConfigurationECONORH.S, the outdoor relative humidity sensor configuration option. If the user selects one of the Honeywell curves, A,B,C or D, then OA.E.C options 1-4 should be selected. See Fig. 10 for a diagram of these curves on a psychrometric chart. CONTROL CURVE A B C D CONTROL POINT (approx Deg) AT 50% RH 73 68 63 58 Fig. 10 — Psychrometric Chart for Enthalpy Control OA.E.C = 1 Honeywell A Curve OA.E.C = 2 Honeywell B Curve OA.E.C = 3 Honeywell C Curve OA.E.C = 4 Honeywell D Curve OA.E.C = 5 custom enthalpy curve If the user selects OA.E.C = 5, a direct comparison of outdoor enthalpy versus an enthalpy set point is done. This outdoor enthalpy set point limit is configurable, and is called ConfigurationECONOA.EN. Depending on what ConfigurationECONOA.E.C is configured for, if the outdoor enthalpy exceeds the Honeywell curves or the outdoor enthalpy compare value (Configuration ECONOA.EN), then free cooling will not be allowed. Differential Enthalpy Changeover — This option compares the outdoor-air enthalpy to the return air enthalpy and chooses the option with the lowest enthalpy. This option should be used in climates with high humidity conditions. This option uses both humidity sensors and dry bulb sensors to calculate the enthalpy of the outdoor and return air. An accessory outdoor air humidity sensor (ORH.S) and return air humidity sensor (RRH.S) are used. The outdoor air relative humidity sensor config (ORH.S) and return air humidity sensor config (ConfigurationUNITSENSRRH.S) must be enabled. Outdoor Dewpoint Limit Check — If an outdoor relative humidity sensor is installed, then the control is able to calculate the outdoor air dewpoint temperature and will compare this temperature against the outside air dewpoint temperature limit configuration (ConfigurationECONO.DEW). If the outdoor air dewpoint temperature is greater than O.DEW, then free cooling will not be allowed. Figure 11 shows a horizontal limit line in the custom curve of the psychrometric chart. This is the outdoor air dewpoint limit boundary. 61 Table 79 — Economizer Configuration Table ITEM EC.EN EC.MN EC.MX E.TRM E.SEL OA.E.C OA.EN OAT.L O.DEW ORH.S E.TYP EC.SW E.CFG E.P.GN E.RNG E.SPD E.DBD UEFC FC.CF FC.TM FC.L.O EXPANSION Economizer Installed? Economizer Min.Position Economizer Max.Position Economzr Trim For SumZ ? Econ ChangeOver Select OA Enthalpy ChgOvr Selct Outdr.Enth Compare Value High OAT Lockout Temp OA Dewpoint Temp Limit Outside Air RH Sensor Economizer Control Type Economizer Switch Config ECON.OPERATION CONFIGS Economizer Prop.Gain Economizer Range Adjust Economizer Speed Adjust Economizer Deadband UNOCC.ECON.FREE COOLING Unoc Econ Free Cool Cfg Unoc Econ Free Cool Time Un.Ec.Free Cool OAT Lock RANGE Yes/No 0 - 100 0 - 100 Yes/No 0-3 1-5 18 - 28 -40 - 120 50 - 62 Enable/Disable 1-3 0-2 0.7 - 3.0 0.5 - 5 0.1 - 10 0.1 - 2 0-2 0 - 720 40 - 70 UNITS CCN POINT ECON_ENA ECONOMIN ECONOMAX ECONTRIM ECON_SEL OAEC_SEL OAEN_CFG OAT_LOCK OADEWCFG OARHSENS ECON_CTL ECOSWCFG DEFAULT Yes 5 98 Yes 0 4 24 60 55 Disable 1 0 ^F EC_PGAIN EC_RANGE EC_SPEED EC_DBAND 1 2.5 0.75 0.5 min dF UEFC_CFG UEFCTIME UEFCNTLO 0 120 50 % % dF dF ^F to the occupied cooling set point. Once the need for cooling has been satisfied during this cycle, the fan will be stopped. Configuring the economizer for Unoccupied Economizer Free Cooling is done in the UEFC group. There are three configuration options, FC.CF, FC.TM and FC.LO. Unoccupied Economizer Free Cooling Configuration (FC.CF) — This option is used to configure the type of unoccupied economizer free cooling control that is desired. 0 = disable unoccupied economizer free cooling 1 = perform unoccupied economizer free cooling as available during the entire unoccupied period. 2 = perform unoccupied economizer free cooling as available, FC.TM minutes before the next occupied period. Unoccupied Economizer Free Cooling Time Configuration (FC.TM) — This option is a configurable time period, prior to the next occupied period, that the control will allow unoccupied economizer free cooling to operate. This option is only applicable when FC.CF = 2. Custom Psychrometric Curves — Refer to the psychrometric chart and the standard Honeywell A-D curves in Fig. 10. The curves start from the bottom and rise vertically, angle to the left and then fold over. This corresponds to the limits imposed by dry bulb changeover, outdoor enthalpy changeover and outdoor dewpoint limiting respectively. Therefore, it is now possible to create any curve desired with the addition of one outdoor relative humidity sensor and the options for changeover now available. See Fig. 11 for an example of a custom curve constructed on a psychrometric chart. UNOCCUPIED ECONOMIZER FREE COOLING — This Free Cooling function is used to start the supply fan and use the economizer to bring in outside air when the outside temperature is cool enough to pre-cool the space. This is done to delay the need for mechanical cooling when the system enters the occupied period. This function requires the use of a space temperature sensor. When configured, the economizer will modulate during an unoccupied period and attempt to maintain space temperature A48-7731 Fig. 11 — Custom Changeover Curve Example 62 cooling” is located at Run StatusVIEWEC.C.P. This is the economizer control point. The control selects set points differently, based on the control type of the unit. This control type can be found at ConfigurationUNITC.TYP. There are 6 types of control. C.TYP = 1 VAV-RAT C.TYP = 2 VAV-SPT C.TYP = 3 TSTAT Multi-Staging C.TYP = 4 TSTAT 2 Stage C.TYP = 5 SPT Multi-Staging C.TYP = 6 SPT 2 Stage If the economizer is not allowed to do free cooling, then EC.C.P = 0. If the economizer is allowed to do free cooling and the Unoccupied Free Cooling Mode is ON, then EC.C.P = SetpointsSASP + InputsRSETSA.S.R. If the economizer is allowed to do free cooling and the Dehumidification mode is ON, then EC.C.P = the Cooling Control Point (Run StatusVIEWCL.C.P). If the C.TYP is either 4 or 6, and the unit is in a cool mode, then If Stage = 0 EC.C.P = the Cooling Control Point (Run StatusVIEWCL.C.P) If Stage = 1 53.0 + economizer suction pressure reset (see below) If Stage = 2 48.0 + economizer suction pressure reset (see below) NOTE: To check the current cooling stage go to Run Status CoolCUR.S. If the C.TYP is either 1,2,3 or 5, and the unit is in a cool mode, then EC.C.P = the Cooling Control Point (Run Status VIEWCL.C.P). Economizer Suction Pressure Reset for Two-Stage Cooling — If the unit’s control type is set to either 2-stage thermostat or 2-stage space temperature control, then there is no cooling control point. Stages 1 and 2 are brought on based on demand, irrespective of the evaporator discharge temperature. In this case, the economizer monitors suction pressure and resets the economizer control point accordingly in order to protect the unit from freezing. For those conditions when the economizer opens up fully but is not able to make set point, and then a compressor comes on, it is conceivable that the coil might freeze. This can be indirectly monitored by checking suction pressure. Rather than fail a circuit, the control will attempt to protect the unit by resetting the economizer control point until the suction pressure rises out of freezing conditions. If either circuit’s suction pressure drops to within 5 psig of the low suction pressure trip point, the control will start adding reset to the economizer control point if it is active. It will be possible to reset the control point upwards, 10 degrees (2 degrees per psig), between the low suction pressure trip point of 52 psig for 48/50AJ,AK,AW,AY units or 93 psig for 48/50A2,A3,A4,A5 units. If this does not work, and if the suction pressure drops below the trip point, then the control will further reset the control point 1 degree every 15 seconds up to a maximum of 10 degrees. The resulting effect will be to warm up the mixed air entering the evaporator, thereby raising the suction pressure. Unoccupied Economizer Free Cooling Outside Lockout Temperature (FC.LO) — This configuration option allows the user to select an outside-air temperature below which unoccupied free cooling is not allowed. This is further explained in the logic section. Unoccupied Economizer Free Cooling Logic — The following qualifications that must be true for unoccupied free cooling to operate: • Unit configured for an economizer • Space temperature sensor enabled and sensor reading within limits • Unit is in the unoccupied mode • FC.CF set to 1 or FC.CF set to 2 and control is within FC.TM minutes of the next occupied period • Not in the Temperature Compensated Start Mode • Not in a cooling mode • Not in a heating mode • Not in a tempering mode • Outside-air temperature sensor reading within limits • Economizer would be allowed to cool if the fan were requested and in a cool mode • OAT > FC.LO (1.0° F hysteresis applied) • Unit not in a fire smoke mode • No fan failure when configured to for unit to shut down on a fan failure If all of the above conditions are satisfied: Unoccupied Economizer Free Cooling will start when both of the following conditions are true: {SPT > (OCSP + 2)} AND {SPT > (OAT + 8)} The Unoccupied Economizer Free Cooling Mode will stop when either of the following conditions are true: {SPT < OCSP} OR {SPT < (OAT + 3)} where SPT = Space Temperature and OCSP = Occupied Cooling Set Point. When the Unoccupied Economizer Free Cooling mode is active, the supply fan is turned on and the economizer damper modulated to control to the supply air set point (Setpoints SASP) plus any supply air reset that may be applied (Inputs RSETSA.S.R). ECONOMIZER OPERATION CONFIGURATION — The configuration items in the E.CFG menu group affect how the economizer modulates when attempting to follow an economizer cooling set point. Typically, they will not need adjustment. In fact, it is strongly advised not to adjust these configuration items from their default settings without first consulting a service engineering representative. In addition, the economizer cooling algorithm is designed to automatically slow down the economizer actuator’s rate of travel as outside air temperature decreases. ECONOMIZER DIAGNOSTIC HELP — Because there are so many conditions which might disable the economizer from being able to provide free cooling, the control has a display table to identify these potentially disabling sources. The user can check ACTV, the “Economizer Active” flag. If this flag is set to Yes there is no reason to check DISA (Economizer Disabling Conditions). If the flag is set to No, this means that at least one or more of the flags under the group DISA are set to Yes and the user can discover what is preventing the economizer from performing free cooling by checking the table. The economizer’s reported and commanded positions are also viewable, as well as outside air temperature, relative humidity, enthalpy and dew point temperature. The following information can be found under the Local Display Mode Run StatusECON. See Table 80. Economizer Control Point Determination Logic — Once the economizer is allowed to provide free cooling, the economizer must determine exactly what set point it should try to maintain. The set point the economizer attempts to maintain when “free Building Pressure Control — The building pressure control sequence provides control of the pressure in the building through the modulating flow rate function of the modulating power exhaust option. This function also provides control of the constant volume 2-stage power exhaust option. BUILDING PRESSURE CONFIGURATION — The building pressure configurations are found at the local display under ConfigurationBP. See Table 81. 63 Table 80 — Economizer Run Status Table ITEM ECN.P ECN.C ACTV DISA UNAV R.EC.D DBC DEW DDBC OAEC DEC EDT OAT FORC SFON CLOF OAQL HELD DH.DS O.AIR OAT OA.RH OA.E OA.D.T EXPANSION Economizer Act.Curr.Pos. Economizer Act.Cmd.Pos. Economizer Active ? ECON DISABLING CONDITIONS Econ Act. Unavailable? Remote Econ. Disabled? DBC - OAT Lockout? DEW - OA Dewpt.Lockout? DDBD- OAT > RAT Lockout? OAEC- OA Enth Lockout? DEC - Diff.Enth.Lockout? EDT Sensor Bad? OAT Sensor Bad ? Economizer Forced ? Supply Fan Not On 30s ? Cool Mode Not In Effect? OAQ Lockout in Effect ? Econ Recovery Hold Off? Dehumid. Disabled Econ.? OUTSIDE AIR INFORMATION Outside Air Temperature Outside Air Rel. Humidity Outside Air Enthalpy Outside Air Dewpoint Temp RANGE 0-100 0-100 YES/NO UNITS % % YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO WRITE STATUS forcible ECONUNAV ECONDISA DBC_STAT DEW_STAT DDBCSTAT OAECSTAT DEC_STAT EDT_STAT OAT_STAT ECONFORC SFONSTAT COOL_OFF OAQLOCKD ECONHELD DHDISABL dF % dF Building Pressure Config (BP.CF) — This configuration selects the type of building pressure control. • BP.CF = 0, No building pressure control • BP.CF = 1, constant volume two-stage power exhaust based on economizer position • BP.CF = 2, multiple stage building pressure control based on a building pressure sensor • BP.CF = 3, VFD building pressure control based on a building pressure sensor Building Pressure PID Run Rate (BP.RT) — This configuration selects the run time of the PID algorithm. This configuration is only active when BP.CF = 3. It is recommended that this value not be changed without guidance from Service Engineering. Building Pressure Proportional Gain (BP.P) — This configuration selects the proportional gain of the PID algorithm. This configuration is only active when BP.CF = 3. It is recommended that this value not be changed without guidance from Service Engineering. Building Pressure Integral Gain (BP.I) — This configuration selects the integral gain of the PID algorithm. This configuration is only active when BP.CF = 3. It is recommended that this value not be changed without guidance from Service Engineering. Building Pressure Derivative Gain (BP.D) — This configuration selects the derivative gain of the PID algorithm. This configuration is only active when BP.CF = 3. It is recommended that this value not be changed without guidance from Service Engineering. Building Pressure Set Point Offset (BP.SO) — This configuration is the value below the building pressure set point to which the building pressure must fall in order to turn off power exhaust control. This configuration is only active when BP.CF = 3. Building Pressure Minimum Speed (BP.MN) — This configuration is the minimum allowed VFD speed during building pressure control. This configuration is only active when BP.CF = 3. Building Pressure Maximum Speed (BP.MX) — This configuration is the maximum allowed VFD speed during building pressure control. This configuration is only active when BP.CF = 3. VFD Fire Speed (BP.FS) — This configuration is the VFD speed override when the control is in the purge or evacuation smoke control modes. This configuration is only active when BP.CF = 3. Power Exhaust Motors (BP.MT) — This configuration is machine dependent and instructs the building pressure control CCN POINT ECONOPOS ECONOCMD ECACTIVE OAT OARH OAE OADEWTMP forcible forcible algorithm as to whether the unit has 4 or 6 motors to control. The motors are controlled by three power exhaust relays A, B, and C. These relay outputs are located at the local display under OutputsFANSPE.A,B,C. The following table illustrates the number of motors each relay is in control of based on BP.MT: BP.MT 1 (4 motors) 2 (6 motors) PE_A Relay 1 Motor 1 Motor PE_B Relay 2 Motors 2 Motors PE_C Relay 1 Motor 3 Motors Building Pressure Sensor (BP.S) — This configuration allows the reading of a building pressure sensor when enabled. This is automatically enabled when BP.CF = 2 or 3. Building Pressure (+/–) Range (BP.R) — This configuration establishes the range in in. wg that a 4 to 20 mA sensor will be scaled to. The control only allows sensors that measure both positive and negative pressure. Building Pressure SETP (BP.SP) — This set point is the building pressure control set point. If the unit is configured for modulating building pressure control, then this is the set point that the control will control to. Power Exhaust on Setp.1 (BP.P1) — When configured for building pressure control type BP.CF = 1 (constant volume twostage control), the control will turn on the first power exhaust fan when the economizer’s position exceeds this set point. Power Exhaust on Setp.1 (BP.P2) — When configured for building pressure control type BP.CF = 1 (constant volume twostage control), the control will turn on the second power exhaust fan when the economizer’s position exceeds this set point. Modulating PE Algorithm Select (BP.SL) — This configuration selects the algorithm used to step the power exhaust stages. This must be set to 1 at all times. The other selections are not used. Building Pressure PID Evaluation Time (BP.TM) — This configuration is the run time rate of the multiple stage (modulating) power exhaust algorithm (BP.CF=2). Building Pressure Threshold Adjustment (BP.ZG) — This configuration is not used. It currently has no effect on building pressure control. High Building Pressure Level (BP.HP) — This configuration is the threshold level above the building pressure set point used to control stages of power exhaust when BP.SL=1. Low Building Pressure Level (BP.LP) — This configuration is the threshold level below the building pressure set point used to control stages of power exhaust when BP.SL=1. 64 The number of power exhaust stages available for this control algorithm is a function of the number of motors it supports. This number of motors is defined by the ConfigurationBP BP.MT configuration. Table 83 illustrates the staging tables for this control algorithm based on BP.MT. The following configurations are used in the controlling of building pressure with this algorithm: • ConfigurationBPB.CFGBP.HP (building pressure high threshold level) • ConfigurationBPB.CFGBP.LP (building pressure low threshold level) • ConfigurationBPB.CFGBP.TM (building pressure timer) This control function is allowed to add or select power exhaust stages at any time, except that a delay time must expire after a stage is added or subtracted. Any time a stage change is made, a timer is started which delays staging for 10 * BP.TM seconds. The default for BP.TM is 1, therefore the delay between stage changes is set to 10 seconds. The logic to add or subtract a stage of power exhaust is as follows: • If building pressure (PressuresAIR.PBP) is greater than the building pressure set point (Configuration BPBPSP) plus the building pressure high threshold level (ConfigurationBPB.CFGBP.HP) add a stage of power exhaust. CONSTANT VOLUME 2-STAGE CONTROL (BP.CF = 1) OPERATION — Two exhaust fan relays will be turned on and off based on economizer position. The two trip set points are BP.P1 and BP.P2. If the economizer is greater than or equal to BP.P1, then power exhaust stage 1 is requested and a 60-second timer is initialized. If the economizer is 5% below the BP.P1, then power exhaust stage 1 is turned off. Also, if the economizer position is less than BP.P1 and the 60-second timer has expired, power exhaust stage 1 is turned off. The same logic applies to the second power exhaust stage, except the BP.P2 trip point is monitored. If the economizer position is greater than or equal to BP.P2, then power exhaust stage 2 is energized and a 60-second timer is initialized. If the economizer is 5% below the BP.P2 the second power exhaust stage turned off. If the economizer is less than BP.P2 and the 60-second timer has expired, second stage power exhaust is turned off. For BP.CF=1, the Table 82 illustrates the power exhaust stages 1 and 2, relay combinations based upon Configuration BP.MT (4 or 6 motors). MULTIPLE POWER EXHAUST STAGE BUILDING PRESSURE CONTROL (BP.CF = 2) OPERATION — Building pressure control is active whenever the supply fan is running. The control algorithm to be used (BP.SL=1) is a timed threshold technique for bringing stages of power exhaust on and off. Table 81 — Building Pressure Configuration ITEM BP BP.CF BP.RT BP.P BP.I BP.D BP.SO BP.MN BP.MX BP.FS BP.MT BP.S BP.R BP.SP BP.P1 BP.P2 B.CFG BP.SL BP.TM BP.ZG BP.HP BP.LP EXPANSION BUILDING PRESS. CONFIG Building Press. Config Bldg.Pres.PID Run Rate Bldg. Press. Prop. Gain Bldg.Press.Integ.Gain Bldg.Press.Deriv.Gain BP Setpoint Offset BP VFD Minimum Speed BP VFD Maximum Speed VFD/Act. Fire Speed/Pos. Power Exhaust Motors Building Pressure Sensor Bldg Press (+/–) Range Building Pressure Setp. Power Exhaust On Setp.1 Power Exhaust On Setp.2 BP ALGORITHM CONFIGS Modulating PE Alg. Slct. BP PID Evaluation Time BP Threshold Adjustment High BP Level Low BP Level RANGE 0-3 5-120 0-5 0-2 0-5 0.0 - 0.5 0-100 0-100 0-100 1-2 Enable/Dsable 0 - 1.00 -0.25 -> 0.25 0 - 100 0 - 100 1-3 0 - 10 0.1 - 10.0 0 - 1.000 0 - 1.000 UNITS CCN POINT "H2O "H2O % % BLDG_CFG BPIDRATE BLDGP_PG BLDGP_IG BLDGP_DG BPSO BLDGPMIN BLDGPMAX BLDGPFSO PWRM BPSENS BP_RANGE BPSP PES1 PES2 min "H2O "H2O "H2O BPSELECT BPPERIOD BPZ_GAIN BPHPLVL BPLPLVL sec "H2O % % % DEFAULT 0* 10 0.5 0.5 0.3 0.05 10 100 100 1* Dsable* 0.25 0.05 35 75 1 1 1 0.05 0.04 *Some configurations are machine dependent. Table 82 — Power Exhaust Staging (BP.CF = 1) BP.MT = 1 (4 motors) Power Exhaust Stage 0 Power Exhaust Stage 1 Power Exhaust Stage 2 PE.A OFF OFF ON PE.B OFF ON ON PE.C OFF OFF ON BP.MT = 2 (6 motors) Power Exhaust Stage 0 Power Exhaust Stage 1 Power Exhaust Stage 2 PE.A OFF OFF ON PE.B OFF OFF ON PE.C OFF ON ON 65 Table 83 — Power Exhaust Staging (BP.CF = 2) BP.MT = 1 (4 motors) Power Exhaust Stage 0 Power Exhaust Stage 1 Power Exhaust Stage 2 Power Exhaust Stage 3 Power Exhaust Stage 4 PE.A OFF ON OFF ON ON PE.B OFF OFF ON ON ON PE.C OFF OFF OFF OFF ON BP.MT = 2 (6 motors) Power Exhaust Stage 0 Power Exhaust Stage 1 Power Exhaust Stage 2 Power Exhaust Stage 3 Power Exhaust Stage 4 Power Exhaust Stage 5 Power Exhaust Stage 6 PE.A OFF ON OFF ON ON OFF ON PE.B OFF OFF ON ON OFF ON ON PE.C OFF OFF OFF OFF ON ON ON • If building pressure (PressuresAIR.PBP) is less than the building pressure set point (Configuration BPBPSP) minus the building pressure low threshold level (ConfigurationBPB.CFGBP.LP) subtract a stage of power exhaust. VFD POWER EXHAUST BUILDING PRESSURE CONTROL (BP.CF = 3) — A 4 to 20mA analog output from Economizer Control Board 1 (ECB-1, AO1) is provided as a speed reference for a field-installed VFD power exhaust accessory. If building pressure (PressuresAIR.PBP) rises above the building pressure set point (BP.SP) and the supply fan is on, then building pressure control is initialized. Thereafter, if the supply fan relay goes off or if the building pressure drops below the BP.SP minus the building pressure set point offset (BP.SO) for 5 continuous minutes, building pressure control will be stopped. The 5-minute timer will continue to reinitialize if the VFD is still commanded to a speed > 0%. If the building pressure falls below the set point, the VFD will slow down automatically. Control is performed with a PID loop where: Error = BP – BP.SP K = 1000 * BP.RT/60 (normalize the PID control for run rate) P = K * BP.P * (error) I = K * BP.I * (error) + “I” calculated last time through the PID D = K * BP.D * (error – error computed last time through the PID) VFD speed reference (clamped between BP.MN and BP.MX%) = P + I + D Smoke Purge — TB6-13 and 15 Each mode must be energized individually on discrete inputs and the corresponding alarm is initiated when a mode is activated. The fire system provides a normally closed dry contact closure. Multiple smoke control inputs, sensed by the control will force the unit into a Fire Shutdown mode. FIRE-SMOKE INPUTS — These discrete inputs can be found on the local display under InputsFIRE. ITEM FIRE FSD PRES EVAC PURG EXPANSION RANGE FIRE-SMOKE INPUTS Fire Shutdown Input Pressurization Input Evacuation Input Smoke Purge Input ALRM/NORM ALRM/NORM ALRM/NORM ALRM/NORM CCN WRITE POINT STATUS FSD PRES EVAC PURG forcible forcible forcible forcible Fire Shutdown Mode — This mode will cause an immediate and complete shutdown of the unit. Pressurization Mode — This mode attempts to raise the pressure of a space to prevent smoke infiltration from an adjacent space. Opening the economizer (thereby closing the return air damper), shutting down power exhaust and turning the indoor fan on will increase pressure in the space. Evacuation Mode — This mode attempts to lower the pressure of the space to prevent infiltrating an adjacent space with its smoke. Closing the economizer (thereby opening the returnair damper), turning on the power exhaust and shutting down the indoor fan decrease pressure in the space. Smoke Purge Mode — This mode attempts to draw out smoke from the space after the emergency condition. Opening the economizer (thereby closing the return-air damper), turning on both the power exhaust and indoor fan will evacuate smoke and bring in fresh air. AIRFLOW CONTROL DURING THE FIRE-SMOKE MODES — All non-smoke related control outputs will get shut down in the fire-smoke modes. Those related to airflow will be controlled as explained below. The following matrix specifies all actions the control shall undertake when each mode occurs (outputs are forced internally with CCN priority number 1 - “Fire”): Smoke Control Modes — There are four smoke con- trol modes that can be used to control smoke within areas serviced by the unit: Pressurization mode, Evacuation mode, Smoke Purge mode, and Fire Shutdown. Evacuation, Pressurization and Smoke Purge modes require the Controls Expansion Board (CEM). The Fire Shutdown input is located on the main board (MBB) on terminals TB5-10 and 11. The unit may also be equipped with a factory-installed return air smoke detector that is wired to TB5-10 and 11 and will shut the unit down if a smoke condition is determined. Field-monitoring wiring can be connected to terminal TB5-8 and 9 to monitor the smoke detector. Inputs on the CEM board can be used to put the unit in the Pressurization, Evacuation, and Smoke Purge modes. These switches or inputs are connected to TB6 as shown below. Refer to Major System Components section on page 101 for wiring diagrams. Pressurization — TB6-12 and 13 Evacuation — TB6-13 and 14 DEVICE Economizer Indoor Fan — VFD Power Exhaust Heat Interlock Relay FIRE PRESSURIZATION PURGE EVACUATION SHUTDOWN 100% 100% 0% 0% ON/FSO* ON/FSO* OFF OFF OFF ON/FSO* ON/FSO* OFF ON ON OFF OFF *“FSO” refers to the supply VFD fire speed override configurable speed. 66 configurable amount, which is referred to as Differential Air Quality Low Limit (DAQ.L). If OAQ is not being measured, OAQ can be manually configured. It should be set at around 400 to 450 ppm or measured with a handheld sensor during the commissioning of the unit. The OAQ reference level can be set using the OAQ Reference Set Point (OAQ.U). When the differential between IAQ and OAQ reaches the configurable Diff. Air Quality Hi Limit (DAQ.H), then the economizer position will be EC.MN. When the IAQ–OAQ differential is between DAQ.L and DAQ.H, the control will modulate the damper between IAQ.M and EC.MN as shown in Fig. 12. The relationship is a linear relationship but other non-linear options can be used. The damper position will never exceed the bounds specified by IAQ.M and EC.MN during IAQ control. If the building is occupied and the indoor fan is running and the differential between IAQ and OAQ is less than DAQ.L, the economizer will remain at IAQ.M. The economizer will not close completely. The damper position will be 0 when the fan is not running or the building is unoccupied. The damper position may exceed EC.MN in order to provide free cooling. The ComfortLink controller is configured for air quality sensors which provide 4 mA at 0 ppm and 20 mA at 2000 ppm. If a sensor has a different range, these bounds must be reconfigured. These pertinent configurations for ranging the air quality sensors are IQ.R.L, IQ.R.H, OQ.R.L and OQ.R.H. The bounds represent the PPM corresponding to 4 mA (low) and 20 mA (high) for IAQ and OAQ, respectively. If OAQ exceeds the OAQ Lockout Value (OAQ.L), then the economizer will remain at IAQ.M. This is used to limit the use of outside air which outdoor air CO2 levels are above the OAQ.L limit. Normally a linear control of the damper vs. the IAQ control signal can be used, but the control also supports non-linear control. Different curves can be used based on the Diff.AQ Responsiveness Variable (IAQ.R). See Fig. 13. SETTING UP THE SYSTEM — The IAQ configuration options are under the Local Display Mode ConfigurationIAQ. See Table 84. Economizer Min Position (ConfigurationIAQDCV.C EC.MN) — This is the fully occupied minimum economizer position. IAQ Demand Vent Min Pos. (ConfigurationIAQDCV.C IAQ.M) — This configuration will be used to set the minimum damper position in the occupied period when there is no IAQ demand. IAQ Analog Sensor Config (ConfigurationIAQ AQ.CFIQ.A.C) — This is used to configure the type of IAQ position control. It has the following options: • IQ.A.C = 0 (No analog input). If there is no other minimum position control, the economizer minimum position will be ConfigurationIAQDCV.CEC.MN and there will be no IAQ control. • IQ.A.C = 1 (IAQ analog input). An indoor air (space or return air) CO2 sensor is installed. If an outdoor air CO2 sensor is also installed, or OAQ is broadcast on the CCN, or if a default OAQ value is used, then the unit can perform IAQ control. • IQ.A.C = 2 (IAQ analog input with minimum position override) — If the differential between IAQ and OAQ is above ConfigurationIAQAQ.SPDAQ.H, the economizer minimum position will be the IAQ override position (ConfigurationIAQAQ.SPIQ.O.P). • IQ.A.C = 3 (4 to 20 mA minimum position) — With a 4 to 20 mA signal connected to TB5-6 and 7, the economizer minimum position will be scaled linearly from 0% (4 mA) to EC.MX (20 mA). RELEVANT ITEMS The economizer’s commanded output can be found in OutputsECONECN.C. The configurable fire speed override for supply fan VFD is in ConfigurationSPSP.FS. The supply fan relay’s commanded output can be found in OutputsFANSS.FAN. The supply fan VFD’s commanded speed can be found in OutputsFANSS.VFD. Indoor Air Quality Control — The indoor air quality (IAQ) function will admit fresh air into the space whenever space air quality sensors detect high levels of CO2. When a space or return air CO2 sensor is connected to the unit control, the unit’s IAQ routine allows a demand-based control for ventilation air quantity, by providing a modulating outside air damper position that is proportional to CO2 level. The ventilation damper position is varied between a minimum ventilation level (based on internal sources of contaminants and CO2 levels other than from the effect of people) and the maximum design ventilation level (determined at maximum populated status in the building). Demand control ventilation (DCV) is also available when the ComfortLink™ unit is connected to a CCN system using ComfortID™ terminal controls. This function also provides alternative control methods for controlling the amount of ventilation air being admitted, including fixed outdoor air ventilation rates (measured as cfm), external discrete sensor switch input and externally generated proportional signal controls. The IAQ function requires the installation of the factoryoption economizer system. The DCV sequences also require the connection of accessory (or field-supplied) space or return air CO2 sensors. Fixed cfm rate control requires the factoryinstalled outdoor air cfm option. External control of the ventilation position requires supplemental devices, including a 4 to 20 mA signal, a 10 kilo-ohm potentiometer, or a discrete switch input, depending on the method selected. Outside air CO2 levels may also be monitored directly and high CO2 economizer restriction applied when an outdoor air CO2 sensor is connected. (The outdoor CO2 sensor connection requires installation of the CEM.) The ComfortLink control system has the capability of DCV using an IAQ sensor. The indoor air quality (IAQ) is measured using a CO2 sensor whose measurements are displayed in parts per million (ppm). The IAQ sensor can be field-installed in the return duct. There is also an accessory space IAQ sensor that can be installed directly in the occupied space. The sensor must provide a 4 to 20 mA output signal and must include its own 24-v supply. The sensor connects to terminal TB5-6 and 7. Be sure to leave the 182-ohm resistor in place on terminals 6 and 7. OPERATION — The unit’s indoor air quality algorithm modulates the position of the economizer damper between two user configurations depending upon the relationship between the IAQ and the outdoor air quality (OAQ). Both of these values can be read at the InputsAIR.Q submenu. The lower of these two configurable positions is referred to as the IAQ Demand Vent Min Position (IAQ.M), while the higher is referred to as Economizer Minimum Position (EC.MN). The IAQ.M should be set to an economizer position that brings in enough fresh air to remove contaminants and CO2 generated by sources other than people. The EC.MN value should be set to an economizer position that brings in enough fresh air to remove contaminants and CO2 generated by all sources including people. The EC.MN value is the design value for maximum occupancy. The logic that is used to control the dampers in response to IAQ conditions is shown in Fig. 12. The ComfortLink™ controls will begin to open the damper from the IAQ.M position when the IAQ level begins to exceed the OAQ level by a 67 • IQ.A.C = 4 (10K potentiometer minimum position) — With a 10K linear potentiometer connected to TB5-6 and 7, the economizer minimum position will be scaled linearly from 0% (0 kilo-ohms) to EC.MX (10 kilo-ohms). IAQ Analog Fan Config (ConfigurationIAQAQ.CF IQ.A.F) — This configuration is used to configure the control of the indoor fan. If this option is used then the IAQ sensor must be in the space and not in the return duct. It has the following configurations: • IQ.A.F = 0 (No Fan Start) — IAQ demand will never override normal indoor fan operation during occupied or unoccupied period and turn it on. • IQ.A.F = 1 (Fan On If Occupied) — IAQ demand will override normal indoor fan operation and turn it on (if off) only during the occupied period (CV operation with automatic fan). • IQ.A.F = 2 (Fan On Occupied/Unoccupied) — IAQ demand will always override normal indoor fan operation and turn it on (if off) during both the occupied and unoccupied period. For IQ.A.F = 1 or 2, the fan will be turned on as described above when DAQ is above the DAQ Fan On Set Point (ConfigurationIAQAQ.SPD.F.ON). The fan will be turned off when DAQ is below the DAQ Fan Off Set Point (ConfigurationIAQAQ.SPD.F.OF). The control can also be set up to respond to a discrete IAQ input. The discrete input is connected to TB5-6 and 7. IAQ Discrete Input Config (ConfigurationIAQAQ.CF IQ.I.C) — This configuration is used to set the type of IAQ sensor. The following are the options: • IQ.I.C = 0 (No Discrete Input) — This is used to indicate that no discrete input will be used and the standard IAQ sensor input will be used. • IQ.I.C = 1 (IAQ Discrete Input) — This will indicate that the IAQ level (high or low) will be indicated by the discrete input. When the IAQ level is low, the economizer minimum position will be Configuration IAQDCV.CIAQ.M. • IQ.I.C = 2 (IAQ Discrete Input with Minimum Position Override) — This will indicate that the IAQ level (high or low) will be indicated by the discrete input and the economizer minimum position will be the IAQ override position, IQ.O.P (when high). It is also necessary to configure how the fan operates when using the IAQ discrete input. IAQ Discrete Fan Config (ConfigurationIAQAQ.CF IQ.I.F) — This is used to configure the operation of the fan during an IAQ demand condition. It has the following configurations: • IQ.I.F = 0 (No Fan Start) — IAQ demand will never override normal indoor fan operation during occupied or unoccupied period and turn it on. • IQ.I.F = 1 (Fan On If Occupied) — IAQ demand will override normal indoor fan operation and turn it on (if off) only during the occupied period (CV operation with automatic fan). • IQ.I.F = 2 (Fan On Occupied/Unoccupied) — IAQ demand will always override normal indoor fan operation and turn it on (if off) during both the occupied and unoccupied period. OAQ 4-20 mA Sensor Config (ConfigurationIAQ AQ.CFOQ.A.C) — This is used to configure the type of outdoor sensor that will be used for OAQ levels. It has the following configuration options: • OQ.A.C = 0 (No Sensor) — No sensor will be used and the internal software reference setting will be used. • OQ.A.C = 1 (OAQ Sensor with DAQ) — An outdoor CO2 sensor will be used. • OQ.A.C = 2 (4 to 20 mA Sensor without DAQ). MINIMUM IAQ DAMPER POSITION INCREASING VENTILATION ECONOMIZER MINIMUM DAMPER POSITION VENTILATION FOR PEOPLE VENTILATION FOR SOURCES 100 500 AQ DIFFERENTIAL LOW (DAQ.L) 700 1000 INSIDE/OUTSIDE CO2 DIFFERENTIAL INSIDE CO2 CONCENTRATION AQ DIFFERENTIAL HIGH (DAQ.H) A48-7209 Fig. 12 — IAQ Control A48-7711 NOTE: Calculating the IAQ.M and EC.MN damper position based on differential IAQ measurement. Based on the configuration parameter IAQREACT, the reaction to damper positioning based on differential air quality ppm can be adjusted. IAQREACT = 1 to 5 (more responsive) IAQREACT = 0 (linear) IAQREACT = –1 to –5 (less responsive) Fig. 13 — IAQ Response Curve 68 IAQ Econo Override Pos (ConfigurationIAQAQ.SP IQ.O.P) — This configuration is the position that the economizer goes to when override is in effect. Diff. Air Quality Lo Limit (ConfigurationIAQAQ.SP DAQ.L) — This is the differential CO2 level at which IAQ control of the dampers will be initiated. Diff. Air Quality Hi Limit (ConfigurationIAQ AQ.SP DAQ.H) — This is the differential CO2 level at which IAQ control of the dampers will be at maximum and the dampers will be at the Configuration IAQDCV.CEC.MN. DAQ ppm Fan Off Set Point (ConfigurationIAQ AQ.SPD.F.OF) — This is the CO2 level at which the indoor fan will be turned off. DAQ ppm Fan On Set Point (Configuration IAQAQ.SPD.F.ON) — This is the CO2 level at which the indoor fan will be turned on. Diff. IAQ Responsiveness (ConfigurationIAQAQ.SP IAQ.R) — This is the configuration that is used to select the IAQ response curves as shown in Fig. 13. OAQ Lockout Value (ConfigurationIAQAQ.SP OAQ.L) — This is the maximum OAQ level above which demand ventilation will be disabled. User Determined OAQ (ConfigurationIAQAQ.SP OAQ.U) — If an OAQ sensor is unavailable, the user can manually set the OAQ reading. IAQ Low Reference (ConfigurationIAQAQ.S.R IQ.R.L) — This is the reference that will be used with a non-Carrier IAQ sensor that may have a different characteristic curve. It represents the CO2 level at 4 mA. IAQ High Reference (ConfigurationIAQAQ.S.R IQ.R.H) — This is the reference that will be used with a non-Carrier IAQ sensor that may have a different characteristic curve. It represents the CO2 level at 20 mA. OAQ Low Reference (ConfigurationIAQAQ.S.R OQ.R.L) — This is the reference that will be used with a non-Carrier OAQ sensor that may have a different characteristic curve. It represents the CO2 level at 4 mA. OAQ High Reference (ConfigurationIAQAQ.S.R OQ.R.H) — This is the reference that will be used with a nonCarrier OAQ sensor that may have a different characteristic curve. It represents the CO2 level at 20 mA. PRE-OCCUPANCY PURGE — The control has the option for a pre-occupancy purge to refresh the air in the space prior to occupancy. This feature is enabled by setting ConfigurationIAQ IAQ.PIQ.PG to Yes. The IAQ purge will operate under the following conditions: • IQ.PG is enabled • the unit is in the unoccupied state • Current Time is valid • Next Occupied Time is valid • time is within two hours of the next occupied period • time is within the purge duration (Configuration IAQIAQ.PIQ.P.T) If all of the above conditions are met, the following logic is used: If OAT IQ.L.O and OAT OCSP and economizer is available then purge will be enabled and the economizer will be commanded to 100%. If OAT < IQ.L.O then the economizer will be positioned to the IAQ Purge LO Temp Min Pos (Configuration IAQIAQ.PIQ.P.L) If neither of the above are true then the dampers will be positioned to the IAQ Purge HI Temp Min Pos (Configuration IAQIAQ.PIQ.P.H) If this mode is enabled the indoor fan and heat interlock relay (VAV) will be energized. IAQ Purge (Configuration IAQ IAQ.P IQ.PG) — This is used to enable IAQ pre-occupancy purge. IAQ Purge Duration (ConfigurationIAQIAQ.P IQ.P.T) — This is the maximum amount of time that a purge can occur. IAQ Purge Lo Temp Min Pos (ConfigurationIAQ IAQ.PIQ.P.L) — This is used to configure a low limit for damper position to be used during the purge mode. IAQ Purge Hi Temp Min Pos (ConfigurationIAQ IAQ.PIQ.P.H) — This is used to configure a maximum position for the dampers to be used during the purge cycle. IAQ Purge OAT Lockout Temp (ConfigurationIAQ IAQ.PIQ.L.O) — Nighttime lockout temperature below which the purge cycle will be disabled. Dehumidification and Reheat — The Dehumidification function will override comfort condition set points based on dry bulb temperature and deliver cooler air to the space in order to satisfy a humidity set point at the space or return air humidity sensor. The Reheat function will energize a suitable heating system concurrent with dehumidification sequence should the dehumidification operation result in excessive cooling of the space condition. The dehumidification sequence requires the installation of a space or return air humidity sensor or a discrete switch input. An ECB option is required to accommodate an RH (relative humidity) sensor connection. A CEM (option or accessory) is required to accomodate an RH switch. Reheat is possible when multiple-step staged gas control option or hydronic heat fieldinstalled coil is installed. Reheat is also possible using a heat reclaim coil (field-supplied and installed) or a DX (direct expansion) reheat coil. Dehumidification and reheat control are allowed during Cooling and Vent modes in the Occupied period. On constant volume units using thermostat inputs (C.TYP = 3 or 4), the discrete switch input must be used as the dehumidification control input. The commercial Thermidistat™ device is the recommended accessory device. SETTING UP THE SYSTEM — The settings for dehumidification can be found at the local display at Configuration DEHU. See Table 85. Dehumidification Configuration (D.SEL) — The dehumidification configuration can be set for the following settings: • D.SEL = 0 — No dehumidification and reheat. • D.SEL = 1 — The control will perform dehumidification and reheat with staged gas only. • D.SEL = 2 — The control will perform both dehumidification and reheat with third party heat via an alarm relay. In the case of D.SEL=2, during dehumidification, the alarm relay will close to convey the need for reheat. A typical application might be to energize a 3-way valve to perform DX reheat. Dehumidification Sensor (D.SEN) — The sensor can be configured for the following settings: • D.SEN = 1 — Initiated by return air relative humidity sensor. • D.SEN = 2 — Initiated by discrete input. Economizer Disable in Dehum Mode (D.EC.D) — This configuration determines economizer operation during Dehumidification mode. • D.EC.D = YES — Economizer disabled during dehumidification (default). • D.EC.D = NO — Economizer not disabled during dehumidification. 69 Table 84 — Indoor Air Quality Configuration ITEM DCV.C EC.MN IAQ.M AQ.CF IQ.A.C IQ.A.F IQ.I.C IQ.I.F OQ.A.C AQ.SP IQ.O.P DAQ.L DAQ.H D.F.OF D.F.ON IAQ.R OAQ.L OAQ.U AQ.S.R IQ.R.L IQ.R.H OQ.R.L OQ.R.H IAQ.P IQ.PG IQ.P.T IQ.P.L IQ.P.H IQ.L.O EXPANSION DCV ECONOMIZER SETPOINTS Economizer Min.Position IAQ Demand Vent Min.Pos. AIR QUALITY CONFIGS IAQ Analog Sensor Config IAQ 4-20 ma Fan Config IAQ Discrete Input Config IAQ Disc.In. Fan Config OAQ 4-20ma Sensor Config AIR QUALITY SETPOINTS IAQ Econo Override Pos. Diff.Air Quality LoLimit Diff. Air Quality HiLimit DAQ PPM Fan Off Setpoint DAQ PPM Fan On Setpoint Diff. AQ Responsiveness OAQ Lockout Value User Determined OAQ AIR QUALITY SENSOR RANGE IAQ Low Reference IAQ High Reference OAQ Low Reference OAQ High Reference IAQ PRE-OCCUPIED PURGE IAQ Purge IAQ Purge Duration IAQ Purge LoTemp Min Pos IAQ Purge HiTemp Min Pos IAQ Purge OAT Lockout RANGE UNITS 0 - 100 0 - 100 CCN POINT % % 0-4 0-2 0-2 0-2 0-2 0 - 100 0 - 1000 100 - 2000 0 - 2000 0 - 2000 -5 - 5 0 - 2000 0 - 5000 % 0 - 5000 0 - 5000 0 - 5000 0 - 5000 Yes/No 5 - 60 0 - 100 0 - 100 35 - 70 min % % dF DEFAULT ECONOMIN IAQMINP 5 0 IAQANCFG IAQANFAN IAQINCFG IAQINFAN OAQANCFG 0 0 0 0 0 IAQOVPOS DAQ_LOW DAQ_HIGH DAQFNOFF DAQFNON IAQREACT OAQLOCK OAQ_USER 100 100 700 200 400 0 0 400 IAQREFL IAQREFH OAQREFL OAQREFH 0 2000 0 2000 IAQPURGE IAQPTIME IAQPLTMP IAQPHTMP IAQPNTLO No 15 10 35 50 Table 85 — Dehumidification Configuration ITEM DEHU D.SEL D.SEN D.EC.D D.V.CF D.V.RA D.V.HT D.C.SP D.RH.S EXPANSION DEHUMIDIFICATION CONFIG. Dehumidification Config Dehumidification Sensor Econ disable in DH mode? Vent Reheat Setpt Select Vent Reheat RAT offset Vent Reheat Setpoint Dehumidify Cool Setpoint Dehumidify RH Setpoint RANGE 0-2 1-2 Yes/No 0-1 0-8 55-95 40-55 10-90 UNITS ^F dF dF % CCN POINT DHSELECT DHSENSOR DHECDISA DHVHTCFG DHVRAOFF DHVHT_SP DHCOOLSP DHRELHSP DEFAULT 0 1 Yes 0 0 70 45 55 NOTE: Configuring ConfigurationDEHUD.SEN to 2 will enable the CEM board along with the sensor selected for control. NOTE: If ConfigurationDEHUD.SEL = 1 or 2, then staged gas control will be automatically enabled (ConfigurationHEATHT.CF will be set to 3). If a tempering, unoccupied or “mechanical cooling locked out” HVAC mode is present, dehumidification will be disabled. An HVAC Off, Vent or Cool mode must be in effect to launch either a Reheat or Dehumidification mode. If an associated sensor responsible for dehumidification fails, dehumidification will not be attempted (SPRH, RARH). Initiating a Reheat or Dehumidification Mode — To call out a Reheat mode in the Vent or the Off HVAC mode, or to call out a Dehumidification mode in a Cool HVAC mode, one of the following conditions must be true: • The space is occupied and the humidity is greater than the relative humidity trip point (D.RH.S). • The space is occupied and the discrete humidity input is closed. Dehumidification and Reheat Control — If a dehumidification mode is initiated, the rooftop will attempt to lower humidity as follows: • Economizer Cooling — The economizer, if allowed to perform free cooling, will have its control point (Run StatusVIEWEC.C.P) set to ConfigurationDEHU D.C.SP. If ConfigurationDEHUD.EC.D is disabled, the economizer will always be disabled during dehumidification. • Cooling — For all cooling control types: A High Cool HVAC mode will be requested internally to the control to Vent Reheat Set Point Select (D.V.CF) — This configuration determines how the vent reheat set point is selected. • D.V.CF = 0 — Reheat follows an offset subtracted from return air temperature (D.V.RA). • D.V.CF = 1 — Reheat follows a dehumidification heat set point (D.V.HT). Vent Reheat RAT Offset (D.V.RA) — Set point offset used only during the vent mode. The air will be reheated to returnair temperature less this offset. Vent Reheat Set Point (D.V.HT) — Set point used only during the vent mode. The air will be reheated to this set point. Dehumidify Cool Set Point (D.C.SP) — This is the dehumidification cooling set point. Dehumidity RH Set Point (D.RH.S) — This is the dehumidification relative humidity trip point. OPERATION — Dehumidification and reheat can only occur if the unit is equipped with either staged gas or hydronic heat. Dehumidification without reheat can be done on any unit but ConfigurationDEHUD.SEL must be set to 2. If the machine’s control type is a TSTAT type (ConfigurationUNITC.TYP=3 or 4) and the discrete input selection for the sensor is not configured (D.SEN not equal to 2), dehumidification will be disabled. If the machine’s control type is a TSTAT type (ConfigurationUNITC.TYP=3 or 4) and the economizer is able to provide cooling, a dehumidification mode may be called out, but the control will not request mechanical cooling. If a 2-stage control type is selected (ConfigurationUNIT C.TYP = 4 or 6), then the economizer, if active, locks out mechanical cooling during the Dehumidification mode. 70 maintain diagnostics, although the end user will see a Dehumidification mode at the display. In addition, for multi-stage cooling units the cooling control point will be set to ConfigurationDEHUD.C.SP (no SASP reset is applied). • Reheat When Cooling Demand is Present — For reheat control during dehumidification: If reheat follows an offset subtracted from return-air temperature (ConfigurationDEHUD.SEL = 2), then no heating will be initiated and the alarm relay will be energized. If ConfigurationDEHUD.SEL = 1 and ConfigurationHEATHT.CF = staged gas or hot water valve, then the selected heating control type will operate in the low heat/modulating mode. • The heating control point will be whatever the actual cooling set point would have been (without any supply air reset applied). • Reheat During Vent Mode — If configured (ConfigurationDEHUD.V.CF = 0), the heating control point will be equal to RAT – D.V.RA. If configured (ConfigurationDEHUD.V.CF=1), the heating control point will be equal to the D.V.HT set point. Ending Dehumidification and Reheat Control — When either the humidity sensor fall 5% below the set point (ConfigurationDEHUD.RH.S) or the discrete input reads “LOW”, the Dehumidification mode will end. occupied state. Once set, Temperature Compensated mode will stay on until the unit goes into the Occupied mode. The Start Bias Time will be written into the CCN Linkage Equipment Table if the unit is controlled in DAV mode. If the Unoccupied Economizer Free Cool mode is active (Operating Modes HVAC = “UNOCC FREE COOL”) when temperature compensated start begins, the Unoccupied Free Cool mode will be stopped. Carrier Comfort Network® (CCN) System — It is possible to configure the ComfortLink™ control to participate as an element of the Carrier Comfort Network (CCN) system directly from the local display. This section will deal with explaining the various programmable options which are found under the CCN sub-menu in the Configuration mode. The major configurations for CCN programming are located in the local displays at ConfigurationCCN. See Table 86. CCN Address (CCNA) — This configuration is the CCN address the rooftop is assigned. CCN Bus Number (CCNB) — This configuration is the CCN bus the rooftop is assigned. CCN Baud Rate (BAUD) — This configuration is the CCN baud rate. For units equipped with the optional UPC, the CCN Baud Rate must be set to 9600. CCN Time/Date Broadcast (TM.DT) — If this configuration is set to ON, the control will periodically send the time and date out onto the CCN bus once a minute. If this device is on a CCN network then it will be important to make sure that only one device on the bus has this configuration set to ON. If more than one time broadcaster is present, problems with the time will occur. NOTE: Only the time and date broadcaster can perform daylight savings time adjustments. Even if the rooftop is stand alone, the user may want to set this to ON to accomplish the daylight/savings function. CCN OAT Broadcast (OAT.B) — If this configuration is set to ON, the control will periodically broadcast its outside-air temperature at a rate of once every 30 minutes. CCN OARH Broadcast (ORH.B) — If this configuration is set to ON, the control will periodically broadcast its outside air relative humidity at a rate of once every 30 minutes. CCN OAQ Broadcast (OAQ.B) — If this configuration is set to ON, the control will periodically broadcast its outside air quality reading at a rate of once every 30 minutes. Global Schedule Broadcast (G.S.B) — If this configuration is set to ON and the schedule number (SCH.N) is between 65 and 99, then the control will broadcast the internal time schedule once every 2 minutes. CCN Broadcast Acknowledger (B.ACK) — If this configuration is set to ON, then when any broadcasting is done on the bus, this device will respond to and acknowledge. Only one device per bus can be configured for this option. Schedule Number (SCH.N) — This configuration determines what schedule the control may follow. SCH.N = 0 The control is always occupied. SCH.N = 1 The control follows its internal time schedules. The user may enter any number between 1 and 64 but it will be overwritten to “1” by the control as it only has one internal schedule. SCH.N = 65-99 The control is either set up to receive to a broadcasted time schedule set to this number or the control is set up to broadcast its internal time schedule (G.S.B) to the network and this is the global schedule number it is broadcasting. If this is the case, then the control still follows its internal time schedules. Temperature Compensated Start — This logic is used when the unit is in the unoccupied state. The control will calculate early Start Bias time based on Space Temperature deviation from the occupied cooling and heating set points. This will allow the control to start the unit so that the space is at conditioned levels when the occupied period starts. This is required for ASHRAE 90.1 compliance. A space sensor is required for non-linkage applications. SETTING UP THE SYSTEM — The settings for temperature compensated start can be found in the local display under ConfigurationUNIT. ITEM TCS.C TCS.H EXPANSION RANGE UNITS CCN POINT Temp.Cmp.Strt.Cool Factr 0 - 60 min TCSTCOOL Temp.Cmp.Strt.Heat Factr 0 - 60 min TCSTHEAT TCST-Cool Factor (TCS.C) — This is the factor for the start time bias equation for cooling. TCST-Heat Factor (TCS.H) — This is the factor for the start time bias equation for heating. NOTE: Temperature compensated start is disabled when these factors are set to 0. TEMPERATURE COMPENSATED START LOGIC — The following conditions must be met: • Unit is in unoccupied state. • Next occupied time is valid. • Current time of day is valid. • Valid space temperature reading is available (sensor or DAV-Linkage). The algorithm will calculate a Start Bias time in minutes using the following equations: If (space temperature > occupied cooling set point) Start Bias Time = (space temperature – occupied cooling set point)* TCS.C If (space temperature < occupied heating set point) Start Bias Time = (occupied heating set point – space temperature)*TCS.H When the Start Bias Time is greater than zero the algorithm will subtract it from the next occupied time to calculate the new start time. When the new start time is reached, the Temperature Compensated Start mode is set (Operating ModesMODE T.C.ST), the fan is started and the unit controlled as in an 71 Table 86 — CCN Configuration ITEM CCN CCNA CCNB BAUD BROD TM.DT OAT.B ORH.B OAQ.B G.S.B B.ACK SC.OV SCH.N HOL.T O.T.L. OV.EX SPT.O T58.O GL.OV EXPANSION CCN CONFIGURATION CCN Address CCN Bus Number CCN Baud Rate CCN BROADCST DEFINITIONS CCN Time/Date Broadcast CCN OAT Broadcast CCN OARH Broadcast CCN OAQ Broadcast Global Schedule Broadcst CCN Broadcast Ack'er CCN SCHEDULES-OVERRIDES Schedule Number Accept Global Holidays? Override Time Limit Timed Override Hours SPT Override Enabled ? T58 Override Enabled ? Global Sched. Override ? RANGE UNITS POINT DEFAULT 1 - 239 0 - 239 1-5 CCNADD CCNBUS CCNBAUDD 1 0 3* ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF CCNBC OATBC OARHBC OAQBC GSBC CCNBCACK On Off Off Off Off Off 0 - 99 YES/NO 0-4 0-4 YES/NO YES/NO YES/NO SCHEDNUM HOLIDAYT OTL OVR_EXT SPT_OVER T58_OVER GLBLOVER 1 No 1 0 Yes Yes No HRS HRS * For units equipped with optional UPC, the CCN Baud Rate must be set to 3. evaporator discharge temperature (EDT) Low Alert Limit (SA.L.O), then Alert 302 will be generated and cooling operation will be stopped but heating operation will continue. The alert will automatically reset. EDT High Alert Limit/Occ (SA.H.O) — If the evaporator discharge temperature is above the configurable occupied EDT High Alert Limit (SA.H.O), then Alert 303 will be generated and heating operation will be stopped but cooling operation will continue. The alert will automatically reset. EDT Low Alert Limit/Unocc (SA.L.U) — If the evaporator discharge temperature is below the configurable unoccupied EDT Low Alert Limit (SA.L.U), then Alert 302 will be generated and cooling operation will be stopped but heating operation will continue. The alert will automatically reset. EDT High Alert Limit/Unocc (SA.H.U) — If the evaporator discharge temperature is above the configurable unoccupied EDT High Alert Limit (SA.H.U), then Alert 303 will be generated and heating operation will be stopped but cooling operation will continue. The alert will automatically reset. RAT Low Alert Limit/Occ (RA.L.O) — If the return-air temperature is below the configurable occupied RAT Low Alert Limit (RA.L.O), then Alert 304 will be generated and internal routines will be modified. Unit operation will continue but VAV heating operation will be disabled. The alert will automatically reset. RAT High Alert Limit/Occ (RA.H.O) — If the return-air temperature is above the configurable occupied RAT High Alert Limit (RA.H.O), then Alert 305 will be generated and operation will continue. The alert will automatically reset. RAT Low Alert Limit/Unocc (RA.L.U) — If the return-air temperature is below the configurable unoccupied RAT Low Alert Limit (RA.L.U), then Alert 304 will be generated. Unit operation will continue but VAV heating operation will be disabled. The alert will automatically reset. RAT High Alert Limit/Unocc (RA.H.U) — If the return-air temperature is above the configurable unoccupied RAT High Alert Limit (RA.H.U), then Alert 305 will be generated. Operation will continue. The alert will automatically reset. RARH Low Alert Limit (R.RH.L) — If the unit is configured to use a return air relative humidity sensor (ConfigurationUNITSENSRRH.S), and the measured level is below the configurable RH Low Alert Limit (R.RH.L), then Alert 308 will occur. The unit will continue to run and the alert will automatically reset. RARH High Alert Limit (R.RH.H) — If the unit is configured to use a return air relative humidity sensor (ConfigurationUNITSENSRRHS), and the measured level is above the configurable RARH High Alert Limit (R.RH.H), Accept Global Holidays? (HOL.T) — If a device is broadcasting the time on the bus, it is possible to accept the time yet not accept the global holiday from the broadcast message. Override Time Limit (O.T.L) — This configuration allows the user to decide how long an override occurs when it is initiated. The override may be configured from 1 to 4 hours. If the time is set to 0, the override function will become disabled. Timed Override Hours (OV.EX) — This displays the current number of hours left in an override. It is possible to cancel an override in progress by writing “0” to this variable, thereby removing the override time left. SPT Override Enabled? (SPT.O) — If a space sensor is present, then it is possible to override an unoccupied period by pushing the override button on the T55 or T56 sensor. This option allows the user to disable this function by setting this configuration to NO. T58 Override Enabled? (T58.O) — The T58 sensor is a CCN device that allows cooling/heating set points to be adjusted, space temperature to be written to the rooftop unit, and the ability to initiate a timed override. This option allows the user to disable the override initiated from the T58 sensor by setting this option to NO. Global Schedule Override? (GL.OV) — If the control is set to receive global schedules then it is also possible for the global schedule broadcaster to call out an override condition as well. This configuration allows the user to disable the global schedule broadcaster from overriding the control. Alert Limit Configuration — The ALLM submenu is used to configure the alert limit set points. A list is shown in Table 87. SPT Low Alert Limit/Occ (SP.L.O) — If the space temperature is below the configurable occupied SPT Low Alert Limit (SP.L.O), then Alert 300 will be generated and the unit will be stopped. The alert will automatically reset. SPT High Alert Limit/Occ (SP.H.O) — If the space temperature is above the configurable occupied SPT High Alert Limit (SP.H.O), then Alert 301 will be generated and the unit will be stopped. The alert will automatically reset. SPT Low Alert Limit/Unocc (SP.L.U) — If the space temperature is below the configurable unoccupied SPT Low Alert Limit (SP.L.U), then Alert 300 will be generated and the unit will be stopped. The alert will automatically reset. SPT High Alert Limit/Unocc (SP.H.U) — If the space temperature is above the configurable unoccupied SPT High Alert Limit (SP.H.U), then Alert 301 will be generated and the unit will be stopped. The alert will automatically reset. EDT Low Alert Limit/Occ (SA.L.O) — If the evaporator discharge temperature is below the configurable occupied 72 Air Temperature Leaving Supply Fan Sensor (SAT.T) — This variable is used to adjust the supply fan temperature sensor reading. The sensor reading can be adjusted ± 10° F to match the actual measured temperature. Return Air Temperature Sensor Trim (RAT.T) — This variable is used to adjust the return air temperature sensor reading. The sensor reading can be adjusted ± 10° F to match the actual measured temperature. Outdoor Air Temperature Sensor Trim (OAT.T) — This variable is used to adjust the outdoor air temperature sensor reading. The sensor reading can be adjusted ± 10° F to match the actual measured temperature. Space Temperature Sensor Trim (SPT.T) — This variable is used to adjust the space temperature sensor reading. The sensor reading can be adjusted ± 10° F to match the actual measured temperature. Circuit A Saturated Condenser Temperature Trim (CTA.T) — This variable is used to adjust the saturated condenser temperature sensor reading for circuit A. The sensor reading can be adjusted ± 30° F to match the actual measured temperature. Used on 48/50AJ,AK,AW,AY units only. Circuit B Saturated Condenser Temperature Trim (CTB.T) — This variable is used to adjust the saturated condenser temperature sensor reading for circuit B. The sensor reading can be adjusted ± 30° F to match the actual measured temperature. Used on 48/50AJ,AK,AW,AY units only. Suction Pressure Circuit A Trim (SP.A.T) — This variable is used to adjust the suction pressure sensor reading for circuit A. The sensor reading can be adjusted ± 50 psig to match the actual measured pressure. Suction Pressure Circuit B Trim (SP.B.T) — This variable is used to adjust the suction pressure sensor reading for circuit B. The sensor reading can be adjusted ± 50 psig to match the actual measured pressure. then Alert 309 will occur. The unit will continue to run and the alert will automatically reset. Supply Duct Pressure Low Alert Limit (SP.L) — If the unit is a VAV unit with a supply duct pressure sensor and the measured supply duct static pressure is below the configurable SP Low Alert Limit (DP.L), then Alert 310 will occur. The unit will continue to run and the alert will automatically reset. Supply Duct Pressure High Alert Limit (SP.H) — If the unit is a VAV unit with a supply duct pressure sensor and the measured supply duct static pressure is above the configurable SP High Alert Limit (SP.H), then Alert 311 will occur. The unit will continue to run and the alert will automatically reset. Building Pressure Low Alert Limit (BP.L) — If the unit is configured to use modulating power exhaust then a building static pressure limit can be configured using the BP Low Alert Limit (BP.L). If the measured pressure is below the limit then Alert 312 will occur. Building Pressure High Alert Limit (BP.H) — If the unit is configured to use modulating power exhaust then a building static pressure limit can be configured using the BP Hi Alert Limit (BP.H). If the measured pressure is above the limit, then Alert 313 will occur. Indoor Air Quality High Alert Limit (IAQ.H) — If the unit is configured to use a CO2 sensor and the level is above the configurable IAQ High Alert Limit (IAQ.H) then the alert will occur. The unit will continue to run and the alert will automatically reset. Sensor Trim Configuration — The TRIM submenu is used to calibrate the sensor trim settings. The trim settings are used when the actual measured reading does not match the sensor output. The sensor can be adjusted to match the actual measured reading with the trim function. A list is shown in Table 88. IMPORTANT: Sensor trim must not be used to extend unit operation past the allowable operating range. Doing so may void the warranty. Table 87 — Alert Limit Configuration ITEM SP.L.O SP.H.O SP.L.U SP.H.U SA.L.O SA.H.O SA.L.U SA.H.U RA.L.O RA.H.O RA.L.U RA.H.U R.RH.L R.RH.H SP.L SP.H BP.L BP.H IAQ.H EXPANSION SPT lo alert limit/occ SPT hi alert limit/occ SPT lo alert limit/unocc SPT hi alert limit/unocc EDT lo alert limit/occ EDT hi alert limit/occ EDT lo alert limit/unocc EDT hi alert limit/unocc RAT lo alert limit/occ RAT hi alert limit/occ RAT lo alert limit/unocc RAT hi alert limit/unocc RARH low alert limit RARH high alert limit SP low alert limit SP high alert limit BP lo alert limit BP high alert limit IAQ high alert limit RANGE -10-245 -10-245 -10-245 -10-245 -40-245 -40-245 -40-245 -40-245 -40-245 -40-245 -40-245 -40-245 0-100 0-100 0-5 0-5 -0.25-0.25 -0.25-0.25 0-5000 UNITS dF dF dF dF dF dF dF dF dF dF dF dF % % "H2O "H2O "H2O "H2O POINT SPLO SPHO SPLU SPHU SALO SAHO SALU SAHU RALO RAHO RALU RAHU RRHL RRHH SPL SPH BPL BPH IAQH DEFAULT 60 85 45 100 40 100 40 100 60 90 40 100 0 100 0 2 -0.25 0.25 1200 Table 88 — Sensor Trim Configuration ITEM SAT.T RAT.T OAT.T SPT.T CTA.T CTB.T SP.A.T SP.B.T DP.A.T DP.B.T EXPANSION Air Temp Lvg SF Trim RAT Trim OAT Trim SPT Trim Cir A Sat. Cond. Temp Trim Cir B Sat. Cond. Temp Trim Suct.Press.Circ.A Trim Suct.Press.Circ.B Trim Dis.Press.Circ.A Trim Dis.Press.Circ.B Trim RANGE -10 - 10 -10 - 10 -10 - 10 -10 - 10 -30 - 30 -30 - 30 -50 - 50 -50 - 50 -50 - 50 -50 - 50 73 UNITS ^F ^F ^F ^F ^F ^F PSIG PSIG PSIG PSIG POINT SAT_TRIM RAT_TRIM OAT_TRIM SPT_TRIM SCTA_TRIM SCTB_TRIM SPA_TRIM SPB_TRIM DPA_TRIM DPB_TRIM DEFAULT 0 0 0 0 0 0 0 0 0 0 Discharge Pressure Circuit A Trim (DP.A.T) — This variable is used to adjust the discharge pressure sensor reading for circuit A. The sensor reading can be adjusted ± 50 psig to match the actual measured pressure. Used on 48/ 50A2,A3,A4,A5 units only. Discharge Pressure Circuit B Trim (DP.B.T) — This variable is used to adjust the discharge pressure sensor reading for circuit B. The sensor reading can be adjusted ± 50 psig to match the actual measured pressure. Used on 48/ 50A2,A3,A4,A5 units only. 4 to 20 mA Inputs — There are a number of 4 to 20 mA inputs which may be calibrated. These inputs are located in Inputs4-20. They are: • SP.M.T — static pressure milliamp trim • BP.M.T — building pressure milliamp trim • OA.M.T — outside air cfm milliamp trim • RA.M.T — return air cfm milliamp trim • SA.M.T — supply air cfm milliamp trim IAQ Discrete Input — Low (IAQ.L) — The IAQ discrete input is set for normally open when low. If a field-supplied IAQ discrete input is used that is normally closed, change this variable to closed. Fire Shutdown — Off (FSD.L) — The fire shutdown input is set for normally open when off. If a field-supplied fire shutdown input is used that is normally closed, change this variable to closed. Pressurization Switch — Off (PRS.L) — The pressurization input is set for normally open when off. If a field-supplied pressurization input is used that is normally closed, change this variable to closed. Evacuation Switch — Off (EVC.L) — The evacuation input is set for normally open when off. If a field-supplied evacuation input is used that is normally closed, change this variable to closed. Smoke Purge — Off (PRG.L) — The smoke purge input is set for normally open when off. If a field-supplied smoke purge input is used that is normally closed, change this variable to closed. Discrete Switch Logic Configuration — The SW.LG Display Configuration — The DISP submenu is used to configure the local display settings. A list is shown in Table 90. Test Display LEDs (TEST) — This is used to test the operation of the ComfortLink™ display. Metric Display (METR) — This variable is used to change the display from English units to Metric units. Language Selection (LANG) — This variable is used to change the language of the ComfortLink display. At this time, only English is available. Password Enable (PAS.E) — This variable enables or disables the use of a password. The password is used to restrict use of the control to change configurations. Service Password (PASS) — This variable is the 4-digit numeric password that is required if enabled. submenu is used to configure the normally open/normally closed settings of switches and inputs. This is used when field-supplied switches or input devices are used instead of Carrier devices. The normally open or normally closed setting may be different on a field-supplied device. These points are used to match the control logic to the field-supplied device. The defaults for this switch logic section will not normally need changing. However, if a field-installed switch is used that is different from the Carrier switch, these settings may need adjustment. IMPORTANT: Many of the switch inputs to the control can be configured to operate as normally open or normally closed. Settings for switch logic are found at the local displays under the ConfigurationSW.LG submenu. See Table 89. Filter Status Input — Clean (FTS.L) — The filter status input for clean filters is set for normally open. If a field-supplied filter status switch is used that is normally closed for a clean filter, change this variable to closed. IGC Feedback — Off (IGC.L) — The input for IGC feedback is set for normally open for off. If a field-supplied IGC feedback switch is used that is normally closed for feedback off, change this variable to closed. Remote Switch — Off (RMI.L) — The remote switch is set for normally open when off. If a field-supplied control switch is used that is normally closed for an off signal, change this variable to closed. Economizer Switch — No (ECS.L) — The economizer switch is set for normally open when low. If a field-supplied economizer switch is used that is normally closed when low, change this variable to closed. Fan Status Switch — Off (SFS.L) — The fan status switch input is set for normally open for off. If a field-supplied fan status switch is used that is normally closed, change this variable to closed. Demand Limit Switch 1 — Off (DL1.L) — The demand limit switch no. 1 input is set for normally open for off. If a field-supplied demand limit switch is used that is normally closed, change this variable to closed. Demand Limit Switch 2/Dehumidify — Off (DL2.L) — The demand limit switch no. 2 input is set for normally open for off. If a field-supplied demand limit switch is used that is normally closed, change this variable to closed. Remote Control Switch Input — The remote switch input is located on the ECB-1 board and connected to TB6 terminals 1 and 3. The switch can be used for several remote control functions. See Table 91. Remote Input State (InputsGEN.IREMT) — This is the actual real time state of the remote input. Remote Switch Config (ConfigurationUNIT RM.CF) — This is the configuration that allows the user to assign different types of functionality to the remote discrete input. • 0 — NO REMOTE SW — The remote switch will not be used. • 1 — OCC-UNOCC SW — The remote switch input will control the occupancy state. When the remote switch input is ON, the unit will forced into the occupied mode. When the remote switch is OFF, the unit will be forced into the unoccupied mode. • 2 — STRT/STOP — The remote switch input will start and stop the unit. When the unit is commanded to stop, any timeguards in place on compressors will be honored first. When the remote switch is ON, the unit will be commanded to stop. When the remote switch is OFF the unit will be enabled to operate. • 3 — OVERRIDE SW — The remote switch can be used to override any internal or external time schedule being used by the control and force the unit into an occupied mode when the remote input state is ON. When the remote switch is ON, the unit will be forced into an occupied state. When the remote switch is OFF, the unit will use its internal or external time schedules. 74 Table 89 — Switch Logic Configuration ITEM SW.LG FTS.L IGC.L RMI.L ECS.L SFS.L DL1.L DL2.L IAQ.L FSD.L PRS.L EVC.L PRG.L EXPANSION SWITCH LOGIC: NO / NC Filter Status Inpt-Clean IGC Feedback - Off RemSw Off-Unoc-Strt-NoOv Economizer Switch - No Fan Status Sw. - Off Dmd.Lmt.Sw.1 - Off Dmd.Lmt.2 Dehumid - Off IAQ Disc.Input - Low Fire Shutdown - Off Pressurization Sw. - Off Evacuation Sw. - Off Smoke Purge Sw. - Off RANGE CCN POINT Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close FLTSLOGC GASFANLG RMTINLOG ECOSWLOG SFSLOGIC DMD_SW1L DMD_SW2L IAQINLOG FSDLOGIC PRESLOGC EVACLOGC PURGLOGC DEFAULT Open Open Open Open Open Open Open Open Open Open Open Open Table 90 — Display Configuration ITEM TEST METR LANG PAS.E PASS EXPANSION Test Display LEDs Metric Display Language Selection Password Enable Service Password RANGE ON/OFF ON/OFF 0-1(multi-text strings) ENABLE/DISABLE 0000-9999 REMT RM.CF RMI.L EXPANSION RANGE Remote Input State ON/OFF Remote Switch Config 0 - 3 RemSw Open/Close Off-Unoc-Strt-NoOv TIME CLOCK CONFIGURATION This section describes each Time Clock menu item. Not every point will need to be configured for every unit. Refer to the Controls Quick Start section for more information on what set points need to be configured for different applications. The Time Clock menu items are discussed in the same order that they are displayed in the Time Clock table. The Time Clock table is shown in Table 93. Hot Gas Bypass — Hot gas bypass is an active part of the A-Series ComfortLink™ capacity staging and minimum evaporator load protection functions. It is controlled though the Minimum Load Valve function. The hot gas bypass option consists of a solenoid valve with a fixed orifice sized to provide a nominal 3-ton evaporator load bypass. A hot gas refrigerant line routes the bypassed hot gas from Circuit A’s discharge line to Circuit A’s evaporator distributor. When the unit control calls for hot gas bypass, the hot gas enters the evaporator coil and adds refrigeration load to the compressor circuit to reduce the cooling effect from Circuit A. The hot gas bypass system is a factory-installed option installed on Circuit A only. This function is enabled at ConfigurationCOOLMLV. When this function is enabled, an additional stage of cooling capacity is provided by the unit control staging sequences (see Tables 52, 54, 58, and 60). Hour and Minute (HH.MM) — The hour and minute of the time clock are displayed in 24-hour, military time. Time can be adjusted manually by the user. When connected to the CCN, the unit can be configured to transmit time over the network or receive time from a network device. All devices on the CCN should use the same time. Only one device on the CCN should broadcast time or problems will occur. Month of Year (MNTH) — This variable is the current month of the calendar year. Day of Month (DOM) — This variable is the current Space Temperature Offset — Space temperature off- day (1 to 31) of the month. set corresponds to a slider on a T56 sensor that allows the occupant to adjust the space temperature by a configured range during an occupied period. This sensor is only applicable to units that are configured as either 2-Stage SPT or Multi-Stage SPT control (ConfigurationUNITC.TYP = 5 or 6). SP.O.S SP.O.R SPTO EXPANSION Space Temp Offset Sensor Space Temp Offset Range Space Temperature Offset RANGE UNITS Day of Week (DAY) — This variable is the current day of the week (Monday = 1 through Sunday = 7). Year (YEAR) — This variable is the current year (for example, 2005). CCN POINT SPTOSENS Enable/ Disable 1 - 10 SPTO_RNG +- SP.O.R ^F SPTO DEFAULT Off Off 0 Enable 1111 of the offset slider. Space Temperature Offset Range (Configuration UNITSENSSP.O.R) — This configuration establishes the range, in degrees F, that the T56 slider can affect SPTO when adjusting the slider from the far left (-SP.O.R) to the far right (+SP.O.R). The default is 5° F. Space Temperature Offset Value (TemperaturesAIR.T SPTO) — The Space Temperature Offset Value is the reading of the slider potentiometer in the T56 that is resolved to delta degrees based on SP.O.R. CCN POINT RMTIN RMTINCFG RMTINLOG Remote Switch Logic Configuration (Configuration SW.LGRMI.L) — The control allows for the configuration of a normally open/closed status of the remote input switch via RMI.L. If this variable is configured OPEN, then when the switch is open, the remote input switch perceives the logic state as OFF. Correspondingly, if RMI.L is set to CLOSED, the remote input switch will perceive a closed switch as meaning OFF. See Table 92. ITEM POINT TEST DISPUNIT LANGUAGE PASS_EBL PASSWORD Space Temperature Offset Sensor (ConfigurationUNIT SENSSP.O.S) — This configuration disables the reading Table 91 — Remote Switch Configuration ITEM UNITS Local Time Schedule (SCH.L) — This submenu is used to program the time schedules. There are 8 periods (PER.1 through PER.8). Each time period can be used to set up a local schedule for the unit. 75 Table 92 — Remote Switch Logic Configuration REMOTE SWITCH LOGIC CONFIGURATION (RMI.L) OPEN CLOSED SWITCH STATUS REMOTE INPUT STATE (REMT) OPEN CLOSED OPEN CLOSED OFF ON ON OFF 0 REMOTE SWITCH CONFIGURATION (RM.CF) 1 2 3 No Remote Switch Occ-Unocc Switch Start/Stop Override xxxxx xxxxx xxxxx xxxxx Unoccupied Occupied Occupied Unoccupied Start Stop Stop Start No Override Override Override No Override Monday In Period (PER.XDAYSMON) — This variable is used to include or remove Monday from the schedule. Each period is assigned an occupied on and off time. If this variable is set to YES, then Monday will be included in that period’s occupied time schedule. If this variable is set to NO, then the period’s occupied time schedule will not be used on Monday. This variable can be set for Periods 1 through 8. Tuesday In Period (PER.XDAYSTUE) — This variable is used to include or remove Tuesday from the schedule. Each period is assigned an occupied on and off time. If this variable is set to YES, then Tuesday will be included in that period’s occupied time schedule. If this variable is set to NO, then the period’s occupied time schedule will not be used on Tuesday. This variable can be set for Periods 1 through 8. Wednesday In Period (PER.XDAYSWED) — This variable is used to include or remove Wednesday from the schedule. Each period is assigned an occupied on and off time. If this variable is set to YES, then Wednesday will be included in that period’s occupied time schedule. If this variable is set to NO, then the period’s occupied time schedule will not be used on Wednesday. This variable can be set for Periods 1 through 8. Thursday In Period (PER.XDAYSTHU) — This variable is used to include or remove Thursday from the schedule. Each period is assigned an occupied on and off time. If this variable is set to YES, then Thursday will be included in that period’s occupied time schedule. If this variable is set to NO, then the period’s occupied time schedule will not be used on Thursday. This variable can be set for Periods 1 through 8. Friday In Period (PER.XDAYSFRI) — This variable is used to include or remove Friday from the schedule. Each period is assigned an occupied on and off time. If this variable is set to YES, then Friday will be included in that period’s occupied time schedule. If this variable is set to NO, then the period’s occupied time schedule will not be used on Friday. This variable can be set for Periods 1 through 8. Saturday In Period (PER.XDAYSSAT) — This variable is used to include or remove Saturday from the schedule. Each period is assigned an occupied on and off time. If this variable is set to YES, then Saturday will be included in that period’s occupied time schedule. If this variable is set to NO, then the period’s occupied time schedule will not be used on Saturday. This variable can be set for Periods 1 through 8. Sunday In Period (PER.XDAYSSUN) — This variable is used to include or remove Sunday from the schedule. Each period is assigned an occupied on and off time. If this variable is set to YES, then Sunday will be included in that period’s occupied time schedule. If this variable is set to NO, then the period’s occupied time schedule will not be used on Sunday. This variable can be set for Periods 1 through 8. Holiday In Period (PER.XDAYSHOL) — This variable is used to include or remove a Holiday from the schedule. Each period is assigned an occupied on and off time. If this variable is set to YES, then holidays will be included in that period’s occupied time schedule. If this variable is set to NO, then the period’s occupied time schedule will not be used on holidays. This variable can be set for Periods 1 through 8. Occupied From (PER.XOCC) — This variable is used to configure the start time of the Occupied period. All days in the same period set to YES will enter into Occupied mode at this time. Occupied To (PER.XUNC) — This variable is used to configure the end time of the Occupied period. All days in the same period set to YES will exit Occupied mode at this time. Local Holiday Schedules (HOL.L) — This submenu is used to program the local holiday schedules. Up to 30 holidays can be configured. When a holiday occurs, the unit will follow the occupied schedules that have the HOLIDAY IN PERIOD point set to YES. Holiday Start Month (HD.01 to HD.30MON) — This is the start month for the holiday. The numbers 1 to 12 correspond to the months of the year (e.g., January = 1). Holiday Start Day (HD.01 to HD.30DAY) — This is the start day of the month for the holiday. The day can be set from 1 to 31. Holiday Duration (HD.01 to HD.30LEN) — This is the length in days of the holiday. The holiday can last up to 99 days. Daylight Savings Time (DAY.S) — The daylight savings time function is used in applications where daylight savings time occurs. The function will automatically correct the clock on the days configured for daylight savings time. DAYLIGHT SAVINGS START (DS.ST) — This submenu configures the start date and time for daylight savings. Daylight Savings Start Month (DS.STST.MN) — This is the start month for daylight savings time. The numbers 1 to 12 correspond to the months of the year (e.g., January = 1). Daylight Savings Start Week (DS.STST.WK) — This is the start week of the month for daylight savings. The week can be set from 1 to 5. Daylight Savings Start Day (DS.STST.DY) — This is the start day of the week for daylight savings. The day can be set from 1 to 7 (Sunday=1, Monday=2, etc.). Daylight Savings Minutes To Add (DS.STMIN.A) — This is the amount of time that will be added to the time clock for daylight savings. DAYLIGHT SAVINGS STOP (DS.SP) — This submenu configures the end date and time for daylight savings. Daylight Savings Stop Month (DS.SPSP.MN) — This is the stop month for daylight savings time. The numbers 1 to 12 correspond to the months of the year (e.g., January = 1). Daylight Savings Stop Week (DS.SPSP.WK) — This is the stop week of the month for daylight savings. The week can be set from 1 to 5. Daylight Savings Stop Day (DS.SPSP.DY) — This is the stop day of the week for daylight savings. The day can be set from 1 to 7 (Sunday=1, Monday=2, etc.). Daylight Savings Minutes To Subtract (DS.SPMIN.S) — This is the amount of time that will be removed from the time clock after daylight savings ends. 76 Table 93 — Time Clock Configuration ITEM TIME HH.MM DATE MNTH DOM DAY YEAR SCH.L PER.1 PER.1DAYS PER.1DAYSMON PER.1DAYSTUE PER.1DAYSWED PER.1DAYSTHU PER.1DAYSFRI PER.1DAYSSAT PER.1DAYSSUN PER.1DAYSHOL PER.1OCC PER.1UNC Repeat for periods 2-8 HOL.L HD.01 HD.01MON HD.01DAY HD.01LEN Repeat for holidays 2-30 DAY.S DS.ST DS.STST.MN DS.STST.WK DS.STST.DY DS.STMIN.A DS.SP DS.SPSP.MN DS.SPSP.WK DS.SPSP.DY DS.SPMIN.S EXPANSION TIME OF DAY Hour and Minute MONTH,DATE,DAY AND YEAR Month of Year Day of Month Day of Week Year LOCAL TIME SCHEDULE PERIOD 1 DAY FLAGS FOR PERIOD 1 Monday in Period Tuesday in Period Wednesday in Period Thursday in Period Friday in Period Saturday in Period Sunday in Period Holiday in Period Occupied from Occupied to LOCAL HOLIDAY SCHEDULES HOLIDAY SCHEDULE 01 Holiday Start Month Start Day Duration (Days) RANGE DAYLIGHT SAVINGS TIME DAYLIGHT SAVINGS START Month Week Day Minutes to Add DAYLIGHTS SAVINGS STOP Month Week Day Minutes to Subtract POINT DEFAULT 00:00 TIME multi-text strings 0-31 multi-text strings e.g. 2003 MOY DOM DOWDISP YOCDISP YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO 00:00 00:00 PER1MON PER1TUE PER1WED PER1THU PER1FRI PER1SAT PER1SUN PER1HOL PER1_OCC PER1_UNC 0-12 0-31 0-99 HOL_MON1 HOL_DAY1 HOL_LEN1 1 - 12 1-5 1-7 0 - 90 STARTM STARTW STARTD MINADD 4 1 7 60 1 - 12 1-5 1-7 0 - 90 STOPM STOPW STOPD MINSUB 10 5 7 60 Period 1 only Yes Yes Yes Yes Yes Yes Yes Yes 00:00 24:00 Thermistor Troubleshooting — The electronic control uses five 5K-thermistors for the saturated condensing temperature on 48/50AJ,AK,AW,AY units (SCT.A and SCT.B). See Tables 97 and 98 for temperature vs. resistance data. When replacing thermistors SCT.A and SCT.B, reuse the original hardware. These thermistors must be clamped tightly to the hairpins of the condenser. The EDT, OAT, RAT, LAT, T55, T56, and T58 space temperature sensors use 10K thermistors. Resistances at various temperatures are listed in Tables 99 and 100. THERMISTOR/TEMPERATURE SENSOR CHECK — A high quality digital volt-ohmmeter is required to perform this check. 1. Connect the digital voltmeter across the appropriate thermistor terminals at the J8 terminal strip on the main base board. 2. Using the voltage reading obtained, read the sensor temperature from Tables 97-100. 3. To check thermistor accuracy, measure temperature at probe location with an accurate thermocouple-type temperature-measuring instrument. Insulate thermocouple to avoid ambient temperatures from influencing reading. Temperature measured by thermocouple and temperature determined from thermistor voltage reading should be close, 5° F (3° C) if care was taken in applying thermocouple and taking readings. If a more accurate check is required, unit must be shut down and thermistor removed and checked at a known temperature (freezing point or boiling point of water) using either voltage drop measured across thermistor at the J8 terminal, or by determining the resistance with unit shut down and thermistor disconnected from J8. Compare the values determined with the value read by the control in the Temperatures mode using the scrolling marquee display. TROUBLESHOOTING The scrolling marquee display shows the actual operating conditions of the unit while it is running. If there are alarms or there have been alarms, they will be displayed in either the current alarm list or the history alarm list. The Service Test mode allows proper operation of the compressors, fans, and other components to be checked while the unit is not operating. Complete Unit Stoppage — There are several conditions that can cause the unit not to provide heating or cooling. If an alarm is active which causes the unit to shut down, diagnose the problem using the information provided in the Alarms and Alerts section on page 93, but also check for the following: • Cooling and heating loads are satisfied. • Programmed schedule. • General power failure. • Tripped control circuit transformers circuit breakers. • Tripped compressor circuit breakers. • Unit is turned off through the CCN network. Single Circuit Stoppage — If a single circuit stops incorrectly, there are several possible causes. The problem should be investigated using information from the Alarms and Alerts section on page 93. Service Analysis — Detailed service analysis can be found in Tables 94-96 and in Fig. 14. Restart Procedure — Before attempting to restart the machine, check the alarm list to determine the cause of the shutdown. If the shutdown alarm for a particular circuit has occurred, determine and correct the cause before allowing the unit to run under its own control again. When there is problem, the unit should be diagnosed in Service Test mode. The alarms must be reset before the circuit can operate in either Normal mode or Service Test mode. 77 the suction and discharge pressure of circuits A and B. The pressure/voltage characteristics of these transducers are shown in Tables 103 and 104. The accuracy of these transducers can be verified by connecting an accurate pressure gage to the second refrigerant port in the suction line. Transducer Troubleshooting — On 48/50AJ,AK, AW,AY units, the electronic control uses 2 suction pressure transducers to measure the suction pressure of circuits A and B. The pressure/voltage characteristics of these transducers are in shown in Tables 101 and 102. On 48/50A2,A3,A4,A5 units, the electronic control uses 4 pressure transducers to measure Table 94 — Cooling Service Analysis PROBLEM COMPRESSOR DOES NOT RUN Active Alarm Contactor Open 1. Power off. 2. Fuses blown in field power circuit. 3. No control power. SOLUTION Check active alarms using local display. 1. Restore power. 2. After finding cause and correcting, replace with correct size fuse. 3. Check secondary fuse(s); replace with correct type and size. Replace transformer if primary windings receiving power. 4. Check for excessive compressor current draw. Reset breaker; replace if defective. 5. Reset lockout circuit at circuit breaker. 6. Check for refrigerant overcharge, obstruction of outdoor airflow, air in system or whether compressor discharge valve is fully open. Be sure outdoor fans are operating correctly. 7. Tighten all connections. 4. Compressor circuit breaker tripped. 5. Safety device lockout circuit active. 6. High-pressure switch open. 7. Loose electrical connections. Contactor Closed 1. Compressor leads loose. 2. Motor windings open. 3. Single phasing. 1. Check connections. 2. See compressor service literature. 3. Check for blown fuse. Check for loose connection at compressor terminal. 4. Allow 30 to 120 minutes for cool down. See Compressor Safeties section on page 39. 4. ASTP activated (48/50A2,A3,A4,A5 only) COMPRESSOR STOPS ON HIGH PRESSURE Outdoor Fan On 1. High-pressure switch faulty. 2. Airflow restricted. 3. Air recirculating. 4. Noncondensables in system. 5. Refrigerant overcharge. 6. Line voltage incorrect. 7. Refrigerant system restrictions. 1. 2. 3. 4. 5. 6. 7. Replace switch. Remove obstruction. Clear airflow area. Purge and recharge as required. Purge as required. Consult power company. Check or replace filter drier, expansion valve, etc. Check that compressor discharge valve is fully open. 8. Correct wiring. 8. Fan running in reverse direction. Outdoor Fan Off 1. Fan slips on shaft. 2. Motor not running. 3. Motor overload open. 4. Motor burned out. COMPRESSOR CYCLES ON LOW PRESSURE Indoor-Air Fan Running 1. Filter drier plugged. 2. Expansion valve power head defective. 3. Low refrigerant charge. 4. Faulty pressure transducer. Airflow Restricted 1. Coil iced up. 2. Coil dirty. 3. Air filters dirty. 4. Dampers closed. Indoor-Air Fan Stopped 1. Electrical connections loose. 2. Fan relay defective. 3. Motor overload open. 4. Motor defective. 5. Fan belt broken or slipping. LEGEND ASTP — Advanced Scroll Temperature Protection VFD — Variable Frequency Drive 78 1. 2. 3. 4. Tighten fan hub setscrews. Check power and capacitor. Check overload rating. Check for fan blade obstruction. Replace motor. 1. 2. 3. 4. Replace filter drier. Replace power head. Add charge. Check that pressure transducer is connected and secured to suction line. If still not functioning, replace transducer. 1. 2. 3. 4. Check refrigerant charge. Clean coil fins. Clean or replace filters. Check damper operation and position. 1. 2. 3. 4. 5. Tighten all connections. Replace relay. Power supply. Replace motor. Replace or tighten belt. Table 94 — Cooling Service Analysis (cont) PROBLEM COMPRESSOR RUNNING BUT COOLING INSUFFICIENT Suction Pressure Low 1. Refrigerant charge low. 2. Head pressure low. 3. Air filters dirty. 4. Expansion valve power head defective. 5. Indoor coil partially iced. 6. Indoor airflow restricted. Suction Pressure High Heat load excessive. UNIT OPERATES TOO LONG OR CONTINUOUSLY 1. Low refrigerant charge. 2. Control contacts fused. 3. Air in system. 4. Partially plugged expansion valve or filter drier. SYSTEM IS NOISY 1. Piping vibration. 2. Compressor noisy. COMPRESSOR LOSES OIL 1. Leak in system. 2. Crankcase heaters not energized during shutdown. FROSTED SUCTION LINE Expansion valve admitting excess refrigerant. HOT LIQUID LINE 1. Shortage of refrigerant due to leak. 2. Expansion valve opens too wide. FROSTED LIQUID LINE Restricted filter drier. INDOOR FAN CONTACTOR OPEN 1. Power off. 2. Fuses blown in field power circuit. 3. No control power. SOLUTION 1. 2. 3. 4. 5. 6. Add refrigerant. Check refrigerant charge. Clean or replace filters. Replace power head. Check low-pressure setting. Remove obstruction. Check for open doors or windows. 1. 2. 3. 4. Add refrigerant Replace control. Purge and evacuate system. Clean or replace. 1. Support piping as required. 2. Replace compressor. 1. Repair leak. 2. Check wiring and relays. Check heater and replace if defective. Adjust expansion valve. 1. Repair leak and recharge. 2. Adjust expansion valve. Remove restriction or replace. 1. Restore power. 2. After finding cause and correcting, replace with correct fuses. 3. Check secondary fuses. Replace with correct type and size. Replace transformer if primary windings are receiving power. INDOOR FAN CONTACTOR CLOSED 1. VFD overload function tripped. 1. Refer to separate VFD technical manual for troubleshooting instructions. 2. Check connections at motor lead junction box. 3. Check motor windings. 4. Check for blown fuse. Check for loose connections at motor junction box. 5. Check belts. Replace as complete set if necessary. 6. Check for excessive current draw. Reset breaker. Replace if defective. 2. Motor leads loose. 3. Motor windings open. 4. Single phasing. 5. Belts broken or thrown. 6. Circuit breaker tripped. LEGEND ASTP — Advanced Scroll Temperature Protection VFD — Variable Frequency Drive 79 Table 95 — Gas Heating Service Analysis PROBLEM Burners Will Not Ignite. CAUSE Active alarm. No power to unit. No power to IGC (Integrated Gas Control). Heaters off due to time guard to prevent short cycling. Control calling for Cooling. No gas at main burners. Inadequate Heating. Water in gas line. Dirty air filters. Gas input too low. Control calling for W1only (low heat). Unit undersized for load. Restricted airflow. Too much outdoor air. Limit switch cycles main burners. Poor Flame Characteristics. Incomplete combustion (lack of combustion air) results in: Aldehyde odors, CO, sooting flame, or floating flame. Burners Will Not Turn Off. Unit is in minimum on-time. Unit running in Service Test mode. REMEDY Check active alarms using ComfortLink™ scrolling marquee. Check power supply, fuses, wiring, and circuit breakers. Check fuses and plugs. Check using ComfortLink scrolling marquee. Check using ComfortLink scrolling marquee. Check gas line for air and purge as necessary. After purging gas line of air, allow gas to dissipate for at least 5 minutes before attempting to re-light unit. Drain water and install drip. Replace air filters. Check gas pressure at manifold. Refer to gas valve adjustment in Installation, Start-up, and Service Manual. Allow time for W2 to energize. Decrease load. Remove restriction. Check economizer position and configuration. Adjust minimum position using ComfortLink scrolling marquee. Check rotation of blower, thermostat heat anticipator settings, and temperature rise of unit. Adjust as needed. Check all screws around flue outlets and burner compartment. Tighten as necessary. Cracked heat exchanger, replace. Unit is over-fired, reduce input. Adjust gas line or manifold pressure. Check vent for restriction. Clean as necessary. Check orifice to burner alignment. Check using ComfortLink scrolling marquee. Check using ComfortLink scrolling marquee. Table 96 — Electric Heat Service Analysis PROBLEM No Heat. CAUSE Power failure. Fuse blown or circuit breaker tripped. Thermostat occupancy schedule set point not calling for Heating. No 24 vac at primary contactor. No power (high voltage) to L2 of primary contactor. Bad electrical elements. 80 REMEDY Call power company. Replace fuse or reset circuit breaker. Check using ComfortLink scrolling marquee. Check transformer and circuit breaker. Check safety switches “one-shot” backup and auto limit. Power off unit and remove high voltage wires. Check resistance of heater, replace if open. IDM — IGC — LEGEND Induced-Draft Motor Integrated Gas Unit Controller NOTE: Thermostat Fan Switch in the “AUTO” position. A48-5656 Fig. 14 — IGC Service Analysis Logic 81 Table 97 — 5K Thermistor Temperature vs. Resistance (SCT Sensors) (English) TEMP (F) –25 –24 –23 –22 –21 –20 –19 –18 –17 –16 –15 –14 –13 –12 –11 –10 –9 –8 –7 –6 –5 –4 –3 –2 –1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 VOLTAGE DROP (V) 3.699 3.689 3.679 3.668 3.658 3.647 3.636 3.624 3.613 3.601 3.588 3.576 3.563 3.550 3.536 3.523 3.509 3.494 3.480 3.465 3.450 3.434 3.418 3.402 3.386 3.369 3.352 3.335 3.317 3.299 3.281 3.262 3.243 3.224 3.205 3.185 3.165 3.145 3.124 3.103 3.082 3.060 3.038 3.016 2.994 2.972 2.949 2.926 2.903 2.879 2.856 2.832 2.808 2.784 2.759 2.735 2.710 2.685 2.660 2.634 2.609 2.583 2.558 2.532 2.506 2.480 2.454 2.428 2.402 2.376 2.349 2.323 2.296 2.270 2.244 2.217 2.191 2.165 2.138 2.112 2.086 2.060 2.034 2.008 RESISTANCE (Ohms) TEMP (F) 98,010 94,707 91,522 88,449 85,486 82,627 79,871 77,212 74,648 72,175 69,790 67,490 65,272 63,133 61,070 59,081 57,162 55,311 53,526 51,804 50,143 48,541 46,996 45,505 44,066 42,679 41,339 40,047 38,800 37,596 36,435 35,313 34,231 33,185 32,176 31,202 30,260 29,351 28,473 27,624 26,804 26,011 25,245 24,505 23,789 23,096 22,427 21,779 21,153 20,547 19,960 19,393 18,843 18,311 17,796 17,297 16,814 16,346 15,892 15,453 15,027 14,614 14,214 13,826 13,449 13,084 12,730 12,387 12,053 11,730 11,416 11,112 10,816 10,529 10,250 9,979 9,717 9,461 9,213 8,973 8,739 8,511 8,291 8,076 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 VOLTAGE DROP (V) 1.982 1.956 1.930 1.905 1.879 1.854 1.829 1.804 1.779 1.754 1.729 1.705 1.681 1.656 1.632 1.609 1.585 1.562 1.538 1.516 1.493 1.470 1.448 1.426 1.404 1.382 1.361 1.340 1.319 1.298 1.278 1.257 1.237 1.217 1.198 1.179 1.160 1.141 1.122 1.104 1.086 1.068 1.051 1.033 1.016 0.999 0.983 0.966 0.950 0.934 0.918 0.903 0.888 0.873 0.858 0.843 0.829 0.815 0.801 0.787 0.774 0.761 0.748 0.735 0.723 0.710 0.698 0.686 0.674 0.663 0.651 0.640 0.629 0.618 0.608 0.597 0.587 0.577 0.567 0.557 0.548 0.538 0.529 0.520 82 RESISTANCE (Ohms) TEMP (F) 7,686 7,665 7,468 7,277 7,091 6,911 6,735 6,564 6,399 6,238 6,081 5,929 5,781 5,637 5,497 5,361 5,229 5,101 4,976 4,855 4,737 4,622 4,511 4,403 4,298 4,196 4,096 4,000 3,906 3,814 3,726 3,640 3,556 3,474 3,395 3,318 3,243 3,170 3,099 3,031 2,964 2,898 2,835 2,773 2,713 2,655 2,597 2,542 2,488 2,436 2,385 2,335 2,286 2,239 2,192 2,147 2,103 2,060 2,018 1,977 1,937 1,898 1,860 1,822 1,786 1,750 1,715 1,680 1,647 1,614 1,582 1,550 1,519 1,489 1,459 1,430 1,401 1,373 1,345 1,318 1,291 1,265 1,240 1,214 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 VOLTAGE DROP (V) 0.511 0.502 0.494 0.485 0.477 0.469 0.461 0.453 0.445 0.438 0.430 0.423 0.416 0.408 0.402 0.395 0.388 0.381 0.375 0.369 0.362 0.356 0.350 0.344 0.339 0.333 0.327 0.322 0.317 0.311 0.306 0.301 0.296 0.291 0.286 0.282 0.277 0.272 0.268 0.264 0.259 0.255 0.251 0.247 0.243 0.239 0.235 0.231 0.228 0.224 0.220 0.217 0.213 0.210 0.206 0.203 0.200 0.197 0.194 0.191 0.188 0.185 0.182 0.179 0.176 0.173 0.171 0.168 0.165 0.163 0.160 0.158 0.155 0.153 0.151 0.148 0.146 0.144 0.142 0.140 0.138 0.135 0.133 RESISTANCE (Ohms) 1,190 1,165 1,141 1,118 1,095 1,072 1,050 1,029 1,007 986 965 945 925 906 887 868 850 832 815 798 782 765 750 734 719 705 690 677 663 650 638 626 614 602 591 581 570 561 551 542 533 524 516 508 501 494 487 480 473 467 461 456 450 445 439 434 429 424 419 415 410 405 401 396 391 386 382 377 372 367 361 356 350 344 338 332 325 318 311 304 297 289 282 Table 98 — 5K Thermistor Temperature vs. Resistance (SCT Sensors) (SI) TEMP (C) –32 –31 –30 –29 –28 –27 –26 –25 –24 –23 –22 –21 –20 –19 –18 –17 –16 –15 –14 –13 –12 –11 –10 –9 –8 –7 –6 –5 –4 –3 –2 –1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 VOLTAGE DROP (V) 3.705 3.687 3.668 3.649 3.629 3.608 3.586 3.563 3.539 3.514 3.489 3.462 3.434 3.406 3.376 3.345 3.313 3.281 3.247 3.212 3.177 3.140 3.103 3.065 3.025 2.985 2.945 2.903 2.860 2.817 2.774 2.730 2.685 2.639 2.593 2.547 2.500 2.454 2.407 2.360 2.312 2.265 2.217 2.170 2.123 2.076 2.029 RESISTANCE (Ohms) TEMP (C) 100,260 94,165 88,480 83,170 78,125 73,580 69,250 65,205 61,420 57,875 54,555 51,450 48,536 45,807 43,247 40,845 38,592 38,476 34,489 32,621 30,866 29,216 27,633 26,202 24,827 23,532 22,313 21,163 20,079 19,058 18,094 17,184 16,325 15,515 14,749 14,026 13,342 12,696 12,085 11,506 10,959 10,441 9,949 9,485 9,044 8,627 8,231 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 VOLTAGE DROP (V) 1.982 1.935 1.889 1.844 1.799 1.754 1.710 1.666 1.623 1.580 1.538 1.497 1.457 1.417 1.378 1.340 1.302 1.265 1.229 1.194 1.160 1.126 1.093 1.061 1.030 0.999 0.969 0.940 0.912 0.885 0.858 0.832 0.807 0.782 0.758 0.735 0.713 0.691 0.669 0.649 0.629 0.610 0.591 0.573 0.555 0.538 0.522 83 RESISTANCE (Ohms) TEMP (C) 7,855 7,499 7,161 6,840 6,536 6,246 5,971 5,710 5,461 5,225 5,000 4,786 4,583 4,389 4,204 4,028 3,861 3,701 3,549 3,404 3,266 3,134 3,008 2,888 2,773 2,663 2,559 2,459 2,363 2,272 2,184 2,101 2,021 1,944 1,871 1,801 1,734 1,670 1,609 1,550 1,493 1,439 1,387 1,337 1,290 1,244 1,200 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 VOLTAGE DROP (V) 0.506 0.490 0.475 0.461 0.447 0.433 0.420 0.407 0.395 0.383 0.371 0.360 0.349 0.339 0.329 0.319 0.309 0.300 0.291 0.283 0.274 0.266 0.258 0.251 0.244 0.237 0.230 0.223 0.217 0.211 0.204 0.199 0.193 0.188 0.182 0.177 0.172 0.168 0.163 0.158 0.154 0.150 0.146 0.142 0.138 0.134 RESISTANCE (Ohms) 1,158 1,118 1,079 1,041 1,006 971 938 906 876 836 805 775 747 719 693 669 645 623 602 583 564 547 531 516 502 489 477 466 456 446 436 427 419 410 402 393 385 376 367 357 346 335 324 312 299 285 Table 99 — 10K Thermistor vs. Resistance (T55, T56, OAT, RAT, EDT, LAT Sensors) (English) TEMP (F) –25 –24 –23 –22 –21 –20 –19 –18 –17 –16 –15 –14 –13 –12 –11 –10 –9 –8 –7 –6 –5 –4 –3 –2 –1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 VOLTAGE DROP (V) 4.758 4.750 4.741 4.733 4.724 4.715 4.705 4.696 4.686 4.676 4.665 4.655 4.644 4.633 4.621 4.609 4.597 4.585 4.572 4.560 4.546 4.533 4.519 4.505 4.490 4.476 4.461 4.445 4.429 4.413 4.397 4.380 4.363 4.346 4.328 4.310 4.292 4.273 4.254 4.235 4.215 4.195 4.174 4.153 4.132 4.111 4.089 4.067 4.044 4.021 3.998 3.975 3.951 3.927 3.903 3.878 3.853 3.828 3.802 3.776 3.750 3.723 3.697 3.670 3.654 3.615 3.587 3.559 3.531 3.503 3.474 3.445 3.416 3.387 3.357 3.328 3.298 3.268 3.238 3.208 3.178 3.147 3.117 3.086 3.056 3.025 RESISTANCE (Ohms) 196,453 189,692 183,300 177,000 171,079 165,238 159,717 154,344 149,194 144,250 139,443 134,891 130,402 126,183 122,018 118,076 114,236 110,549 107,006 103,558 100,287 97,060 94,020 91,019 88,171 85,396 82,729 80,162 77,662 75,286 72,940 70,727 68,542 66,465 64,439 62,491 60,612 58,781 57,039 55,319 53,693 52,086 50,557 49,065 47,627 46,240 44,888 43,598 42,324 41,118 39,926 38,790 37,681 36,610 35,577 34,569 33,606 32,654 31,752 30,860 30,009 29,177 28,373 27,597 26,838 26,113 25,396 24,715 24,042 23,399 22,770 22,161 21,573 20,998 20,447 19,903 19,386 18,874 18,384 17,904 17,441 16,991 16,552 16,131 15,714 15,317 TEMP (F) 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 VOLTAGE DROP (V) 2.994 2.963 2.932 2.901 2.870 2.839 2.808 2.777 2.746 2.715 2.684 2.653 2.622 2.592 2.561 2.530 2.500 2.470 2.439 2.409 2.379 2.349 2.319 2.290 2.260 2.231 2.202 2.173 2.144 2.115 2.087 2.059 2.030 2.003 1.975 1.948 1.921 1.894 1.867 1.841 1.815 1.789 1.763 1.738 1.713 1.688 1.663 1.639 1.615 1.591 1.567 1.544 1.521 1.498 1.475 1.453 1.431 1.409 1.387 1.366 1.345 1.324 1.304 1.284 1.264 1.244 1.225 1.206 1.187 1.168 1.150 1.132 1.114 1.096 1.079 1.062 1.045 1.028 1.012 0.996 0.980 0.965 0.949 0.934 0.919 0.905 84 RESISTANCE (Ohms) 14,925 14,549 14,180 13,824 13,478 13,139 12,814 12,493 12,187 11,884 11,593 11,308 11,031 10,764 10,501 10,249 10,000 9,762 9,526 9,300 9,078 8,862 8,653 8,448 8,251 8,056 7,869 7,685 7,507 7,333 7,165 6,999 6,838 6,683 6,530 6,383 6,238 6,098 5,961 5,827 5,698 5,571 5,449 5,327 5,210 5,095 4,984 4,876 4,769 4,666 4,564 4,467 4,370 4,277 4.185 4,096 4,008 3,923 3,840 3,759 3,681 3,603 3,529 3,455 3,383 3,313 3,244 3,178 3,112 3,049 2,986 2,926 2,866 2,809 2,752 2,697 2,643 2,590 2,539 2,488 2,439 2,391 2,343 2,297 2,253 2,209 TEMP (F) 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 VOLTAGE DROP (V) 0.890 0.876 0.862 0.848 0.835 0.821 0.808 0.795 0.782 0.770 0.758 0.745 0.733 0.722 0.710 0.699 0.687 0.676 0.666 0.655 0.645 0.634 0.624 0.614 0.604 0.595 0.585 0.576 0.567 0.558 0.549 0.540 0.532 0.523 0.515 0.507 0.499 0.491 0.483 0.476 0.468 0.461 0.454 0.447 0.440 0.433 0.426 0.419 0.413 0.407 0.400 0.394 0.388 0.382 0.376 0.370 0.365 0.359 0.354 0.349 0.343 0.338 0.333 0.328 0.323 0.318 0.314 0.309 0.305 0.300 0.296 0.292 0.288 0.284 0.279 0.275 0.272 0.268 0.264 RESISTANCE (Ohms) 2,166 2,124 2,083 2,043 2,003 1,966 1,928 1,891 1,855 1,820 1,786 1,752 1,719 1,687 1,656 1,625 1,594 1,565 1,536 1,508 1,480 1,453 1,426 1,400 1,375 1,350 1,326 1,302 1,278 1,255 1,233 1,211 1,190 1,169 1,148 1,128 1,108 1,089 1,070 1,052 1,033 1,016 998 981 964 947 931 915 900 885 870 855 841 827 814 800 787 774 762 749 737 725 714 702 691 680 670 659 649 639 629 620 610 601 592 583 574 566 557 Table 100 — 10K Thermistor vs. Resistance (T55, T56, OAT, RAT, EDT, LAT Sensors) (SI) TEMP (C) –32 –31 –30 –29 –28 –27 –26 –25 –24 –23 –22 –21 –20 –19 –18 –17 –16 –15 –14 –13 –12 –11 –10 –9 –8 –7 –6 –5 –4 –3 –2 –1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 VOLTAGE DROP (V) 4.762 4.748 4.733 4.716 4.700 4.682 4.663 4.644 4.624 4.602 4.580 4.557 4.533 4.508 4.482 4.455 4.426 4.397 4.367 4.335 4.303 4.269 4.235 4.199 4.162 4.124 4.085 4.044 4.003 3.961 3.917 3.873 3.828 3.781 3.734 3.686 3.637 3.587 3,537 3.485 3.433 3.381 3.328 3.274 3.220 3.165 3.111 RESISTANCE (Ohms) 200,510 188,340 177,000 166,342 156,404 147,134 138,482 130,402 122,807 115,710 109,075 102,868 97,060 91,588 86,463 81,662 77,162 72,940 68,957 65,219 61,711 58,415 55,319 52,392 49,640 47,052 44,617 42,324 40,153 38,109 36,182 34,367 32,654 31,030 29,498 28,052 26,686 25,396 24,171 23,013 21,918 20,883 19,903 18,972 18,090 17,255 16,474 TEMP (C) 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 VOLTAGE DROP (V) 3.056 3.000 2.944 2.889 2.833 2.777 2.721 2.666 2.610 2.555 2.500 2.445 2.391 2.337 2.284 2.231 2.178 2.127 2.075 2.025 1.975 1.926 1.878 1.830 1.784 1.738 1.692 1.648 1.605 1.562 1.521 1.480 1.439 1.400 1.362 1.324 1.288 1.252 1.217 1.183 1.150 1.117 1.086 1.055 1.025 0.996 0.968 RESISTANCE (Ohms) 15,714 15,000 14,323 13,681 13,071 12,493 11,942 11,418 10,921 10,449 10,000 9,571 9,164 8,776 8,407 8,056 7,720 7,401 7,096 6,806 6,530 6,266 6,014 5,774 5,546 5,327 5,117 4,918 4,727 4,544 4,370 4,203 4,042 3,889 3,743 3,603 3,469 3,340 3,217 3,099 2,986 2,878 2,774 2,675 2,579 2,488 2,400 TEMP (C) 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 VOLTAGE DROP (V) 0.940 0.913 0.887 0.862 0.837 0.813 0.790 0.767 0.745 0.724 0.703 0.683 0.663 0.645 0.626 0.608 0.591 0.574 0.558 0.542 0.527 0.512 0.497 0.483 0.470 0.457 0.444 0.431 0.419 0.408 0.396 0.386 0.375 0.365 0.355 0.345 0.336 0.327 0.318 0.310 0.302 0.294 0.287 0.279 0.272 0.265 RESISTANCE (Ohms) 2,315 2,235 2,157 2,083 2,011 1,943 1,876 1,813 1,752 1,693 1,637 1,582 1,530 1,480 1,431 1,385 1,340 1,297 1,255 1,215 1,177 1,140 1,104 1,070 1,037 1,005 974 944 915 889 861 836 811 787 764 742 721 700 680 661 643 626 609 592 576 561 Table 101 — Suction Pressure Transducer Pressure (PSIG) vs. Voltage (SP-A, SP-B, SP.XR=0, 48/50AJ,AK,AW,AY Units Only) PRESSURE (PSIG) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 VOLTAGE DROP (V) 0.290 0.324 0.357 0.391 0.425 0.458 0.492 0.526 0.560 0.593 0.627 0.661 0.694 0.728 0.762 0.795 0.829 0.863 0.897 0.930 0.964 0.998 1.031 1.065 1.099 1.132 1.166 1.200 1.234 1.267 1.301 1.335 1.368 1.402 PRESSURE (PSIG) 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 VOLTAGE DROP (V) 1.436 1.470 1.503 1.537 1.571 1.604 1.638 1.672 1.705 1.739 1.773 1.807 1.840 1.874 1.908 1.941 1.975 2.009 2.042 2.076 2.110 2.144 2.177 2.211 2.245 2.278 2.312 2.346 2.380 2.413 2.447 2.481 2.514 2.548 PRESSURE (PSIG) 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 85 VOLTAGE DROP (V) 2.582 2.615 2.649 2.683 2.717 2.750 2.784 2.818 2.851 2.885 2.919 2.952 2.986 3.020 3.054 3.087 3.121 3.155 3.188 3.222 3.256 3.290 3.323 3.357 3.391 3.424 3.458 3.492 3.525 3.559 3.593 3.627 3.660 3.694 PRESSURE (PSIG) 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 VOLTAGE DROP (V) 3.728 3.761 3.795 3.829 3.862 3.896 3.930 3.964 3.997 4.031 4.065 4.098 4.132 4.166 4.200 4.233 4.267 4.301 4.334 4.368 4.402 4.435 4.469 4.503 4.537 4.570 4.604 4.638 4.671 4.705 4.739 4.772 4.806 4.840 Table 102 — Suction Pressure Transducer Pressure (PSIG) vs. Voltage (SP-A, SP-B, SP.XR = 1, 48/50AJ,AK,AW,AY Units Only) PRESSURE (PSIG) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 VOLTAGE DROP (V) 0.500 0.520 0.540 0.560 0.580 0.600 0.620 0.640 0.660 0.680 0.700 0.720 0.740 0.760 0.780 0.800 0.820 0.840 0.860 0.880 0.900 0.920 0.940 0.960 0.980 1.000 1.020 1.040 1.060 1.080 1.100 1.120 1.140 1.160 1.180 1.200 1.220 1.240 1.260 1.280 1.300 1.320 1.340 1.360 1.380 1.400 1.420 1.440 1.460 1.480 1.500 PRESSURE (PSIG) 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 VOLTAGE DROP (V) 1.520 1.540 1.560 1.580 1.600 1.620 1.640 1.660 1.680 1.700 1.720 1.740 1.760 1.780 1.800 1.820 1.840 1.860 1.880 1.900 1.920 1.940 1.960 1.980 2.000 2.020 2.040 2.060 2.080 2.100 2.120 2.140 2.160 2.180 2.200 2.220 2.240 2.260 2.280 2.300 2.320 2.340 2.360 2.380 2.400 2.420 2.440 2.460 2.480 2.500 PRESSURE (PSIG) 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 86 VOLTAGE DROP (V) 2.520 2.540 2.560 2.580 2.600 2.620 2.640 2.660 2.680 2.700 2.720 2.740 2.760 2.780 2.800 2.820 2.840 2.860 2.880 2.900 2.920 2.940 2.960 2.980 3.000 3.020 3.040 3.060 3.080 3.100 3.120 3.140 3.160 3.180 3.200 3.220 3.240 3.260 3.280 3.300 3.320 3.340 3.360 3.380 3.400 3.420 3.440 3.460 3.480 3.500 PRESSURE (PSIG) 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 VOLTAGE DROP (V) 3.520 3.540 3.560 3.580 3.600 3.620 3.640 3.660 3.680 3.700 3.720 3.740 3.760 3.780 3.800 3.820 3.840 3.860 3.880 3.900 3.920 3.940 3.960 3.980 4.000 4.020 4.040 4.060 4.080 4.100 4.120 4.140 4.160 4.180 4.200 4.220 4.240 4.260 4.280 4.300 4.320 4.340 4.360 4.380 4.400 4.420 4.440 4.460 4.480 4.500 Table 103 — Suction Pressure Transducer (PSIG) vs. Voltage (SP-A, SP-B, 48/50A2,A3,A4,A5 Units Only) PRESSURE (PSIG) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 VOLTAGE DROP (V) 0.466 0.476 0.486 0.495 0.505 0.515 0.525 0.535 0.545 0.554 0.564 0.574 0.584 0.594 0.604 0.614 0.623 0.633 0.643 0.653 0.663 0.673 0.682 0.692 0.702 0.712 0.722 0.732 0.741 0.751 0.761 0.771 0.781 0.791 0.801 0.810 0.820 0.830 0.840 0.850 0.860 0.869 0.879 0.889 0.899 0.909 0.919 0.928 0.938 0.948 0.958 0.968 0.978 0.988 0.997 1.007 1.017 1.027 1.037 1.047 1.056 1.066 1.076 1.086 1.096 1.106 1.116 1.125 1.135 1.145 1.155 1.165 1.175 1.184 1.194 1.204 1.214 1.224 1.234 1.243 1.253 1.263 1.273 1.283 1.293 1.303 1.312 1.322 1.332 1.342 1.352 1.362 1.371 1.381 1.391 1.401 1.411 1.421 1.430 1.440 1.450 1.460 1.470 1.480 1.490 1.499 PRESSURE (PSIG) 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 VOLTAGE DROP (V) 1.509 1.519 1.529 1.539 1.549 1.558 1.568 1.578 1.588 1.598 1.608 1.618 1.627 1.637 1.647 1.657 1.667 1.677 1.686 1.696 1.706 1.716 1.726 1.736 1.745 1.755 1.765 1.775 1.785 1.795 1.805 1.814 1.824 1.834 1.844 1.854 1.864 1.873 1.883 1.893 1.903 1.913 1.923 1.932 1.942 1.952 1.962 1.972 1.982 1.992 2.001 2.011 2.021 2.031 2.041 2.051 2.060 2.070 2.080 2.090 2.100 2.110 2.120 2.129 2.139 2.149 2.159 2.169 2.179 2.188 2.198 2.208 2.218 2.228 2.238 2.247 2.257 2.267 2.277 2.287 2.297 2.307 2.316 2.326 2.336 2.346 2.356 2.366 2.375 2.385 2.395 2.405 2.415 2.425 2.434 2.444 2.454 2.464 2.474 2.484 2.494 2.503 2.513 2.523 2.533 PRESSURE (PSIG) 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 87 VOLTAGE DROP (V) 2.543 2.553 2.562 2.572 2.582 2.592 2.602 2.612 2.622 2.631 2.641 2.651 2.661 2.671 2.681 2.690 2.700 2.710 2.720 2.730 2.740 2.749 2.759 2.769 2.779 2.789 2.799 2.809 2.818 2.828 2.838 2.848 2.858 2.868 2.877 2.887 2.897 2.907 2.917 2.927 2.936 2.946 2.956 2.966 2.976 2.986 2.996 3.005 3.015 3.025 3.035 3.045 3.055 3.064 3.074 3.084 3.094 3.104 3.114 3.124 3.133 3.143 3.153 3.163 3.173 3.183 3.192 3.202 3.212 3.222 3.232 3.242 3.251 3.261 3.271 3.281 3.291 3.301 3.311 3.320 3.330 3.340 3.350 3.360 3.370 3.379 3.389 3.399 3.409 3.419 3.429 3.438 3.448 3.458 3.468 3.478 3.488 3.498 3.507 3.517 3.527 3.537 3.547 3.557 3.566 PRESSURE (PSIG) 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 VOLTAGE DROP (V) 3.576 3.586 3.596 3.606 3.616 3.626 3.635 3.645 3.655 3.665 3.675 3.685 3.694 3.704 3.714 3.724 3.734 3.744 3.753 3.763 3.773 3.783 3.793 3.803 3.813 3.822 3.832 3.842 3.852 3.862 3.872 3.881 3.891 3.901 3.911 3.921 3.931 3.940 3.950 3.960 3.970 3.980 3.990 4.000 4.009 4.019 4.029 4.039 4.049 4.059 4.068 4.078 4.088 4.098 4.108 4.118 4.128 4.137 4.147 4.157 4.167 4.177 4.187 4.196 4.206 4.216 4.226 4.236 4.246 4.255 4.265 4.275 4.285 4.295 4.305 4.315 4.324 4.334 4.344 4.354 4.364 4.374 4.383 4.393 4.403 4.413 4.423 4.433 4.442 4.452 4.462 4.472 4.482 4.492 4.502 4.511 4.521 4.531 4.541 4.551 4.561 4.570 4.580 4.590 4.600 Table 104 — Discharge Pressure Transducer (PSIG) vs. Voltage (DP-A, DP-B, 48/50A2,A3,A4,A5 Units Only) PRESSURE (PSIG) 14.5 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 VOLTAGE DROP (V) 0.500 0.509 0.515 0.521 0.528 0.534 0.540 0.546 0.552 0.558 0.564 0.570 0.577 0.583 0.589 0.595 0.601 0.607 0.613 0.620 0.626 0.626 0.632 0.638 0.644 0.650 0.656 0.662 0.669 0.675 0.681 0.687 0.693 0.699 0.705 0.711 0.718 0.724 0.730 0.736 0.742 0.748 0.754 0.761 0.767 0.773 0.779 0.785 0.791 0.797 0.803 0.810 0.816 0.822 0.828 0.834 0.840 0.846 0.852 0.859 0.865 0.871 0.877 0.883 0.889 0.895 0.902 0.908 0.914 0.920 0.926 0.932 0.938 0.944 0.951 0.957 0.963 0.969 0.975 0.981 0.987 PRESSURE (PSIG) 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 VOLTAGE DROP (V) 0.993 1.000 1.006 1.012 1.018 1.024 1.030 1.036 1.043 1.049 1.055 1.061 1.067 1.073 1.079 1.085 1.092 1.098 1.104 1.110 1.116 1.122 1.128 1.134 1.141 1.147 1.153 1.159 1.165 1.171 1.177 1.184 1.190 1.196 1.202 1.208 1.214 1.220 1.226 1.233 1.239 1.245 1.251 1.257 1.263 1.269 1.275 1.282 1.288 1.294 1.300 1.306 1.312 1.318 1.325 1.331 1.337 1.343 1.349 1.355 1.361 1.367 1.374 1.380 1.386 1.392 1.398 1.404 1.410 1.416 1.423 1.429 1.435 1.441 1.447 1.453 1.459 1.466 1.472 1.478 1.484 PRESSURE (PSIG) 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 88 VOLTAGE DROP (V) 1.490 1.496 1.502 1.508 1.515 1.521 1.527 1.533 1.539 1.545 1.551 1.557 1.564 1.570 1.576 1.582 1.588 1.594 1.600 1.606 1.613 1.619 1.625 1.631 1.637 1.643 1.649 1.656 1.662 1.668 1.674 1.680 1.686 1.692 1.698 1.705 1.711 1.717 1.723 1.729 1.735 1.741 1.747 1.754 1.760 1.766 1.772 1.778 1.784 1.790 1.797 1.803 1.809 1.815 1.821 1.827 1.833 1.839 1.846 1.852 1.858 1.864 1.870 1.876 1.882 1.888 1.895 1.901 1.907 1.913 1.919 1.925 1.931 1.938 1.944 1.950 1.956 1.962 1.968 1.974 1.980 PRESSURE (PSIG) 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 VOLTAGE DROP (V) 1.987 1.993 1.999 2.005 2.011 2.017 2.023 2.029 2.036 2.042 2.048 2.054 2.060 2.066 2.072 2.079 2.085 2.091 2.097 2.103 2.109 2.115 2.121 2.128 2.134 2.140 2.146 2.152 2.158 2.164 2.170 2.177 2.183 2.189 2.195 2.201 2.207 2.213 2.220 2.226 2.232 2.238 2.244 2.250 2.256 2.262 2.269 2.275 2.281 2.287 2.293 2.299 2.305 2.311 2.318 2.324 2.330 2.336 2.342 2.348 2.354 2.361 2.367 2.373 2.379 2.385 2.391 2.397 2.403 2.410 2.416 2.422 2.428 2.434 2.440 2.446 2.452 2.459 2.465 2.471 2.477 Table 104 — Discharge Pressure Transducer (PSIG) vs. Voltage (DP-A, DP-B, 48/50A2,A3,A4,A5 Units Only) (cont) PRESSURE (PSIG) 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 VOLTAGE DROP (V) 2.483 2.489 2.495 2.502 2.508 2.514 2.520 2.526 2.532 2.538 2.544 2.551 2.557 2.563 2.569 2.575 2.581 2.587 2.593 2.600 2.606 2.612 2.618 2.624 2.630 2.636 2.643 2.649 2.655 2.661 2.667 2.673 2.679 2.685 2.692 2.698 2.704 2.710 2.716 2.722 2.728 2.734 2.741 2.747 2.753 2.759 2.765 2.771 2.777 2.784 2.790 2.796 2.802 2.808 2.814 2.820 2.826 2.833 2.839 2.845 2.851 2.857 2.863 2.869 2.875 2.882 2.888 2.894 2.900 2.906 2.912 2.918 2.925 2.931 2.937 2.943 2.949 2.955 2.961 2.967 2.974 2.980 2.986 PRESSURE (PSIG) 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 VOLTAGE DROP (V) 2.992 2.998 3.004 3.010 3.016 3.023 3.029 3.035 3.041 3.047 3.053 3.059 3.066 3.072 3.078 3.084 3.090 3.096 3.102 3.108 3.115 3.121 3.127 3.133 3.139 3.145 3.151 3.157 3.164 3.170 3.176 3.182 3.188 3.194 3.200 3.206 3.213 3.219 3.225 3.231 3.237 3.243 3.249 3.256 3.262 3.268 3.274 3.280 3.286 3.292 3.298 3.305 3.311 3.317 3.323 3.329 3.335 3.341 3.347 3.354 3.360 3.366 3.372 3.378 3.384 3.390 3.397 3.403 3.409 3.415 3.421 3.427 3.433 3.439 3.446 3.452 3.458 3.464 3.470 3.476 3.482 3.488 3.495 PRESSURE (PSIG) 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 89 VOLTAGE DROP (V) 3.501 3.507 3.513 3.519 3.525 3.531 3.538 3.544 3.550 3.556 3.562 3.568 3.574 3.580 3.587 3.593 3.599 3.605 3.611 3.617 3.623 3.629 3.636 3.642 3.648 3.654 3.660 3.666 3.672 3.679 3.685 3.691 3.697 3.703 3.709 3.715 3.721 3.728 3.734 3.740 3.746 3.752 3.758 3.764 3.770 3.777 3.783 3.789 3.795 3.801 3.807 3.813 3.820 3.826 3.832 3.838 3.844 3.850 3.856 3.862 3.869 3.875 3.881 3.887 3.893 3.899 3.905 3.911 3.918 3.924 3.930 3.936 3.942 3.948 3.954 3.961 3.967 3.973 3.979 3.985 3.991 3.997 4.003 PRESSURE (PSIG) 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 VOLTAGE DROP (V) 4.010 4.016 4.022 4.028 4.034 4.040 4.046 4.052 4.059 4.065 4.071 4.077 4.083 4.089 4.095 4.102 4.108 4.114 4.120 4.126 4.132 4.138 4.144 4.151 4.157 4.163 4.169 4.175 4.181 4.187 4.193 4.200 4.206 4.212 4.218 4.224 4.230 4.236 4.243 4.249 4.255 4.261 4.267 4.273 4.279 4.285 4.292 4.298 4.304 4.310 4.316 4.322 4.328 4.334 4.341 4.347 4.353 4.359 4.365 4.371 4.377 4.384 4.390 4.396 4.402 4.408 4.414 4.420 4.426 4.433 4.439 4.445 4.451 4.457 4.463 4.469 4.475 4.482 4.488 4.494 4.500 Run StatusVIEWHT.ST — This variable displays the current number of heating stages active (for staged gas control option only). Compare to following point. Run StatusVIEWH.MAX — This variable displays the maximum number of heat stages available for this model. ECONOMIZER RUN STATUS — The Economizer Run Status display table provides information about the economizer and can be used to troubleshoot economizer problems. See Table 106. The current position, commanded position, and whether the economizer is active can be displayed. All the disabling conditions for the economizer and outside air information is also displayed. COOLING INFORMATION — The Cooling Information run status display table provides information on the cooling operation of the unit. See Table 107. Current Running Capacity (C.CAP) — This variable represents the amount of capacity currently running as a percent. Current Cool Stage (CUR.S) — This variable represents the cool stage currently running. Requested Cool Stage (REQ.S) — This variable represents the requested cool stage. Cooling relay time guards in place may prevent the requested cool stage from matching the current cool stage. Maximum Cool Stages (MAX.S) — This variable is the maximum number of cooling stages the control is configured for and capable of controlling. Active Demand Limit (DEM.L) — If demand limit is active, this variable will represent the amount of capacity that the control is currently limited to. Capacity Load Factor (SMZ) — This factor builds up or down over time (–100 to +100) and is used as the means of adding or subtracting a cooling stage during run time. It is a normalized representation of the relationship between “Sum” and “Z”. See the SUMZ Cooling Algorithm section on page 46. Next Stage EDT Decrease (ADD.R) — This variable represents (if adding a stage of cooling) how much the temperature should drop in degrees depending on the R.PCT calculation and how much additional capacity is to be added. ADD.R = R.PCT * (C.CAP – capacity after adding a cooling stage) For example: If R.PCT = 0.2 and the control would be adding 20% cooling capacity by taking the next step up, 0.2 times 20 = 4 F ADD.R. Next Stage EDT Increase (SUB.R) — This variable represents (if subtracting a stage of cooling) how much the temperature should rise in degrees depending on the R.PCT calculation and how much capacity is to be subtracted. SUB.R = R.PCT * (C.CAP – capacity after subtracting a cooling stage) For Example: If R.PCT = 0.2 and the control would be subtracting 30% capacity by taking the next step down, 0.2 times –30 = –6 F SUB.R. Rise Per Percent Capacity (R.PCT) — This is a real time calculation that represents the amount of degrees of drop/rise across the evaporator coil versus percent of current running capacity. R.PCT = (MAT – EDT)/C.CAP Cap Deadband Subtracting (Y.MIN) — This is a control variable used for Low Temp Override (L.TMP) and Slow Change Override (SLOW). Y.MIN = –SUB.R*0.4375 Cap Deadband Adding (Y.PLU) — This is a control variable used for High Temp Override (H.TMP) and Slow Change Override (SLOW). Y.PLU = –ADD.R*0.4375 Forcing Inputs and Outputs — Many variables may be forced both from the CCN and directly at the local display. This can be useful during diagnostic testing and also during operation, typically as part of an advanced third party control scheme. See Appendices A and B. NOTE: In the case of a power reset, any force in effect at the time of the power reset will be cleared. CONTROL LEVEL FORCING — If any of the following points are forced with a priority level of 7 (consult CCN literature for a description of priority levels), the software clears the force from the point if it has not been written to or forced again within the timeout periods defined below: TemperaturesAIR.TOAT TemperaturesAIR.TRAT TemperaturesAIR.TSPT InputsRSETSP.RS InputsREL.HOA.RH InputsAIR.QOAQ Outside Air Temperature Return Air Temperature Space Temperature Static Pressure Reset Outside Air Relative Humidity Outside Air Quality 30 minutes 3 minutes 3 minutes 30 minutes 30 minutes 30 minutes Run Status Menu — The Run Status menu provides the user important information about the unit. The Run Status table can be used to troubleshoot problems and to help determine how and why the unit is operating. AUTO VIEW OF RUN STATUS — The Auto View of Run Status display table provides the most important unit information. The HVAC Mode (Run StatusVIEWHVAC) informs the user what HVAC mode the unit is currently in. Refer to the Modes section on page 32 for information on HVAC modes. The occupied status, unit temperatures, unit set points, and stage information can also be shown. See Table 105. Run StatusVIEWHVAC — Displays the current HVAC Mode(s) by name. HVAC Modes include: OFF VENT HIGH HEAT STARTING UP HIGH COOL FIRE SHUT DOWN SHUTTING DOWN LOW COOL PRESSURIZATION DISABLED UNOCC FREE COOL EVACUATION SOFTSTOP REQUEST TEMPERING HICOOL SMOKE PURGE REM SW DISABLE TEMPERING LOCOOL COMP STUCK ON TEMPERING VENT TEST LOW HEAT Run StatusVIEWOCC — This variable displays the current occupancy status of the control. Run StatusVIEWMAT — This variable displays the current value for mixed-air temperature. This value is calculated based on return-air and outside-air temperatures and economizer damper position. Run StatusVIEWEDT — This variable displays the current evaporator discharge air temperature during Cooling modes. This value is read at the supply air thermistor location (or at cooling coil thermistor array if unit is equipped with hydronic heating coil). Run StatusVIEWLAT — This variable displays the current leaving-air temperature during Vent and Hydronic Heating modes. This value is read at the supply air thermistor location. Run StatusVIEWEC.C.P — This variable displays the current economizer control point value (a target value for air temperature leaving the evaporator coil location). Run StatusVIEWECN.P — This variable displays the current actual economizer position (in percentage open). Run StatusVIEWCL.C.P — This variable displays the current cooling control point (a target value for air temperature leaving the evaporator coil location). Run StatusVIEWC.CAP — This variable displays the current amount of unit cooling capacity (in percent of maximum). Run StatusVIEWHT.C.P — This variable displays the current heating control point, for use with staged gas control option only (a target value for air temperature leaving the supply duct). 90 Slow Change Cap Override (SLOW) — With a rooftop unit, the design rise at 100% total unit capacity is generally around 30 F. For a unit with 4 stages, each stage represents about 7.5F of change to EDT. If stages could reliably be cycled at very fast rates, the set point could be maintained very precisely. Since it is not desirable to cycle compressors more than 6 cycles per hour, slow change override takes care of keeping the PID under control when “relatively” close to set point. MODE TRIP HELPER — The Mode Trip Helper table provides information on the unit modes and when the modes start and stop. See Table 108. This information can be used to help determine why the unit is in the current mode. CCN/LINKAGE DISPLAY TABLE — The CCN/Linkage display table provides information on unit linkage. See Table 109. COMPRESSOR RUN HOURS DISPLAY TABLE — The Compressor Run Hours Display Table displays the number of run time hours for each compressor. See Table 110. COMPRESSOR STARTS DISPLAY TABLE — The Compressor Starts Display Table displays the number of starts for each compressor. See Table 111. TIME GUARD DISPLAY TABLE — The Time Guard Display Table delay time for each compressor and heat relay. See Table 112. SOFTWARE VERSION NUMBERS DISPLAY TABLE — The Software Version Numbers Display Table displays the software version numbers of the unit boards and devices. See Table 113. Cap Threshold Subtracting (Z.MIN) — This parameter is used in the calculation of SMZ and is calculated as follows: Z.MIN = ConfigurationCOOLZ.GN * (–10 + (4* (–SUB.R))) * 0.6 Cap Threshold Adding (Z.PLU) — This parameter is used in the calculation of SMZ and is calculated as follows: Z.PLU = ConfigurationCOOLZ.GN * (10 + (4* (–ADD.R))) * 0.6 High Temp Cap Override (H.TMP) — If stages of mechanical cooling are on and the error is greater than twice Y.PLU, and the rate of change of error is greater than 0.5 F, then a stage of mechanical cooling will be added every 30 seconds. This override is intended to react to situations where the load rapidly increases. Low Temp Cap Override (L.TMP) — If the error is less than twice Y.MIN, and the rate of change of error is less than –0.5F, then a mechanical stage will be removed every 30 seconds. This override is intended to quickly react to situations where the load is rapidly reduced. Pull Down Cap Override (PULL) — If the error from set point is above 4F, and the rate of change is less than –1F per minute, then pulldown is in effect, and “SUM” is set to 0. This keeps mechanical cooling stages from being added when the error is very large, but there is no load in the space. Pulldown for units is expected to rarely occur, but is included for the rare situation when it is needed. Most likely pulldown will occur when mechanical cooling first becomes available shortly after the control goes into an occupied mode (after a warm unoccupied mode). Table 105 — Auto View of Run Status Display Table ITEM VIEW HVAC OCC MAT EDT LAT EC.C.P ECN.P CL.C.P C.CAP HT.C.P HT.ST H.MAX EXPANSION AUTO VIEW OF RUN STATUS ascii string spelling out the hvac modes Occupied ? Mixed Air Temperature Evaporator Discharge Tmp Leaving Air Temperature Economizer Control Point Economizer Act.Curr.Pos. Cooling Control Point Current Running Capacity Heating Control Point Requested Heat Stage Maximum Heat Stages RANGE UNITS string OCCUPIED MAT EDT LAT ECONCPNT ECONOPOS COOLCPNT CAPTOTAL HEATCPNT HT_STAGE HTMAXSTG YES/NO 0-100 POINT dF dF dF dF % dF dF WRITE STATUS forcible Table 106 — Economizer Run Status Display Table ITEM ECON ECN.P ECN.C ACTV DISA UNAV R.EC.D DBC DEW DDBC OAEC DEC EDT OAT FORC SFON CLOF OAQL HELD O.AIR OAT OA.RH OA.E OA.D.T EXPANSION ECONOMIZER RUN STATUS Economizer Act.Curr.Pos. Economizer Act.Cmd.Pos. Economizer Active ? ECON DISABLING CONDITIONS Econ Act. Unavailable? Remote Econ. Disabled? DBC - OAT Lockout? DEW - OA Dewpt.Lockout? DDBD- OAT > RAT Lockout? OAEC- OA Enth Lockout? DEC - Diff.Enth.Lockout? EDT Sensor Bad? OAT Sensor Bad ? Economizer Forced ? Supply Fan Not On 30s ? Cool Mode Not In Effect? OAQ Lockout in Effect ? Econ Recovery Hold Off? OUTSIDE AIR INFORMATION Outside Air Temperature Outside Air Rel. Humidity Outside Air Enthalpy OutsideAir Dewpoint Temp RANGE 0-100 0-100 YES/NO UNITS % % YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO ECONOPOS ECONOCMD ECACTIVE WRITE STATUS forcible ECONUNAV ECONDISA DBC_STAT DEW_STAT DDBCSTAT OAECSTAT DEC_STAT EDT_STAT OAT_STAT ECONFORC SFONSTAT COOL_OFF OAQLOCKD ECONHELD dF % dF 91 POINT OAT OARH OAE OADEWTMP forcible forcible Table 107 — Cooling Information Display Table ITEM COOL C.CAP CUR.S REQ.S MAX.S DEM.L SUMZ SMZ ADD.R SUB.R R.PCT Y.MIN Y.PLU Z.MIN Z.PLU H.TMP L.TMP PULL SLOW EXPANSION COOLING INFORMATION Current Running Capacity Current Cool Stage Requested Cool Stage Maximum Cool Stages Active Demand Limit COOL CAP. STAGE CONTROL Capacity Load Factor Next Stage EDT Decrease Next Stage EDT Increase Rise Per Percent Capacity Cap Deadband Subtracting Cap Deadband Adding Cap Threshold Subtracting Cap Threshold Adding High Temp Cap Override Low Temp Cap Override Pull Down Cap Override Slow Change Cap Override RANGE UNITS POINT % WRITE STATUS CAPTOTAL COOL_STG CL_STAGE CLMAXSTG DEM_LIM % –100 +100 forcible SMZ ADDRISE SUBRISE RISE_PCT Y_MINUS Y_PLUS Z_MINUS Z_PLUS HI_TEMP LOW_TEMP PULLDOWN SLO_CHNG ^F ^F Table 108 — Mode Trip Helper Display Table ITEM TRIP UN.C.S UN.C.E OC.C.S OC.C.E TEMP OC.H.E OC.H.S UN.H.E UN.H.S HVAC EXPANSION MODE TRIP HELPER Unoccup. Cool Mode Start Unoccup. Cool Mode End Occupied Cool Mode Start Occupied Cool Mode End Ctl.Temp RAT,SPT or Zone Occupied Heat Mode End Occupied Heat Mode Start Unoccup. Heat Mode End Unoccup. Heat Mode Start ascii string spelling out the hvac modes RANGE UNITS POINT WRITE STATUS UCCLSTRT UCCL_END OCCLSTRT OCCL_END CTRLTEMP OCHT_END OCHTSTRT UCHT_END UCHTSTRT string Table 109 — CCN/Linkage Display Table ITEM LINK MODE L.Z.T L.C.SP L.H.SP EXPANSION CCN - LINKAGE Linkage Active - CCN Linkage Zone Control Tmp Linkage Curr. Cool Setpt Linkage Curr. Heat Setpt RANGE UNITS POINT ON/OFF WRITE STATUS MODELINK LZT LCSP LHSP dF dF dF Table 110 — Compressor Run Hours Display Table ITEM HRS HR.A1 HR.A2 HR.B1 HR.B2 EXPANSION COMPRESSOR RUN HOURS Compressor A1 Run Hours Compressor A2 Run Hours Compressor B1 Run Hours Compressor B2 Run Hours RANGE 0-999999 0-999999 0-999999 0-999999 UNITS HRS HRS HRS HRS POINT HR_A1 HR_A2 HR_B1 HR_B2 WRITE STATUS config config config config Table 111 — Compressor Starts Display Table ITEM STRT ST.A1 ST.A2 ST.B1 ST.B2 EXPANSION COMPRESSOR STARTS Compressor A1 Starts Compressor A2 Starts Compressor B1 Starts Compressor B2 Starts RANGE 0-999999 0-999999 0-999999 0-999999 92 UNITS POINT CY_A1 CY_A2 CY_B1 CY_B2 WRITE STATUS config config config config Table 112 — Time Guard Display Table ITEM TMGD TG.A1 TG.A2 TG.B1 TG.B2 TG.H1 TG.H2 TG.H3 TG.H4 TG.H5 TG.H6 EXPANSION TIMEGUARDS Compressor A1 Timeguard Compressor A2 Timeguard Compressor B1 Timeguard Compressor B2 Timeguard Heat Relay 1 Timeguard Heat Relay 2 Timeguard Heat Relay 3 Timeguard Heat Relay 4 Timeguard Heat Relay 5 Timeguard Heat Relay 6 Timeguard RANGE UNITS POINT WRITE STATUS CMPA1_TG CMPA2_TG CMPB1_TG CMPB2_TG HS1_TG HS2_TG HS3_TG HS4_TG HS5_TG HS6_TG Table 113 — Software Version Numbers Display Table ITEM VERS MBB ECB1 ECB2 SCB CEM MARQ NAVI EXPANSION SOFTWARE VERSION NUMBERS CESR131343-xx-xx CESR131249-xx-xx CESR131249-xx-xx CESR131226-xx-xx CESR131174-xx-xx CESR131171-xx-xx CESR130227-xx-xx RANGE UNITS POINT WRITE STATUS string string string string string string string operation. When this occurs, the control turns off the compressor and logs a strike for the respective circuit. These alerts reset automatically. If the current sensor board reads OFF while the compressor relay has been commanded ON for a period of 4 continuous seconds, an alert is generated. Any time this alert occurs, a strike will be called out on the affected compressor. If three successive strikes occur the compressor will be locked out requiring a manual reset or power reset of the circuit board. The clearing of strikes during compressor operation is a combination of 3 complete cycles or 15 continuous minutes of run time operation. So, if there are one or two strikes on the compressor and three short cycles (ON-OFF, ON-OFF, ON-OFF) less than 15 minutes each occur, the strikes will be reset to zero for the affected compressor. Also, if the compressor turns on and runs for 15 minutes straight with no compressor failure, the compressor’s strikes are cleared as well. NOTE: Until the compressor is locked out, for the first two strikes, the alert will not be broadcast to the network, nor will the alarm relay be closed. The possible causes are: • High-pressure switch (HPS) open. The HPS is wired in series with compressor relays on the MBB. If the high-pressure switch opens during compressor operation, the compressor stops, and the CS no longer detects current, causing the control to activate this alert. For 48/50AJ,AK,AW,AY units: • Compressor internal overload protection is open. The internal overloads are used on the Scroll Tech compressors (black) and smaller Maneurop compressors used on the size 020, 025, 027, 030, 035 units and 040 A1, A2 compressors. • Internal compressor temperature sensor trip. The large Maneurop compressors (blue) used on the size 040 (B1, B2), 050, and 060 units have an internal temperature sensor. • Circuit breaker trip. The compressors are protected from short circuit by a breaker in the control box. On the size 020-035 and 040 A1, A2 units there is one breaker per two compressors and on the size 040 (B1, B2), 050, and 060 compressors there is one breaker per compressor because there are not internal overloads. • Wiring error. A wiring error might not allow the compressor to start. Alarms and Alerts — There are a variety of different alerts and alarms in the system. • P — Pre-Alert: Part of the unit is temporarily down. The alarm is not broadcast on the CCN network. The alarm relay is not energized. After an allowable number of retries, if the function does not recover, the pre-alert will be upgraded to an alert or an alarm. • T — Alert: Part of the unit is down, but the unit is still partially able to provide cooling or heating. • A — Alarm: The unit is down and is unable to provide cooling or heating. All alarms are displayed with a code of AXXX where the A is the category of alarm (Pre-Alert, Alert, or Alarm) and XXX is the number. The response of the control system to various alerts and alarms depends on the seriousness of the particular alert or alarm. In the mildest case, an alert does not affect the operation of the unit in any manner. An alert can also cause a “strike.” A “striking” alert will cause the circuit to shut down for 15 minutes. This feature reduces the likelihood of false alarms causing a properly working system to be shut down incorrectly. If three strikes occur before the circuit has an opportunity to show that it can function properly, the circuit will strike out, causing the shutdown alarm for that particular circuit. Once activated, the shutdown alarm can only be cleared via an alarm reset. Circuits with strikes are given an opportunity to reset their strike counter to zero. As discussed above, a strike typically causes the circuit to shut down. Fifteen minutes later, that circuit will once again be allowed to run. If the circuit is able to run for 1 minute, its replacement circuit will be allowed to shut down (if not required to run to satisfy requested stages). However, the “troubled” circuit must run continuously for 5 minutes with no detectable problems before the strike counter is reset to zero. All the alarms and alerts are summarized in Table 114. DIAGNOSTIC ALARM CODES AND POSSIBLE CAUSES T051, P051 (Circuit A, Compressor 1 Failure) T052, P052 (Circuit A, Compressor 2 Failure) T055, P055 (Circuit B, Compressor 1 Failure) T056, P056 (Circuit B, Compressor 2 Failure) — Alert codes 051, 052, 055, and 056 are for compressors A1, A2, B1, and B2 respectively. These alerts occur when the current sensor (CS) does not detect compressor current during compressor 93 Table 114 — Alert and Alarm Codes ALARM OR ALERT DESCRIPTION NUMBER A051 Circuit A, Compressor 1 Stuck On Failure ACTION TAKEN BY CONTROL Turn off all compressors Compressor locked off Welded contact High pressure switch, compressor current, wiring error Exceeded 3 strike limit Welded contact High pressure switch, compressor current, wiring error Exceeded 3 strike limit Welded contact High pressure switch, compressor current, wiring error Exceeded 3 strike limit Welded contact High pressure switch, compressor current, wiring error Exceeded 3 strike limit Use OAT for head pressure control Automatic Faulty thermistor or wiring error Circuit A, Compressor 1 Failure Add strike to compressor T051 A052 Circuit A, Compressor 1 Failure Circuit A, Compressor 2 Stuck On Failure Compressor locked off Turn off all compressors P052 Circuit A, Compressor 2 Failure Add strike to compressor T052 A055 Circuit A, Compressor 2 Failure Circuit B, Compressor 1 Stuck On Failure Compressor locked off Turn off all compressors P055 Circuit B, Compressor 1 Failure Add strike to compressor T055 A056 Circuit B, Compressor 1 Failure Circuit B, Compressor 2 Stuck On Failure Compressor locked off Turn off all compressors P056 Circuit B, Compressor 2 Failure Add strike to compressor T056 T072 T073 T074 T075 T076 T078 T082 T090 T091 T092 T093 T110 T111 Circuit B, Compressor 2 Failure Circuit A Saturated Condensing Thermistor Failure (48/50AJ,AK,AW,AY units only) Circuit B Saturated Condensing Thermistor Failure (48/50AJ,AK,AW,AY units only) Evaporator Discharge Reset Sensor Failure Outside Air Temperature Thermistor Failure Space Temperature Thermistor Failure Return Air Thermistor Failure Outside Air Relative Humidity Sensor Failure Return Air Relative Humidity Sensor Failure Space Temperature Offset Sensor Failure Circuit A Discharge Pressure Transducer Failure Circuit B Discharge Pressure Transducer Failure Circuit A Suction Pressure Transducer Failure Circuit B Suction Pressure Transducer Failure Circuit A Loss of Charge Circuit B Loss of Charge A120 Circuit A Low Saturated Suction Temperature Alarm. P120 Circuit A Low Saturated Suction Temp-Comp A2 Shutdown T120 T065 PROBABLE CAUSE Manual Automatic (max 3) Manual Manual Automatic (max 3) Manual Manual Automatic (max 3) Manual Manual Automatic (max 3) Manual P051 T064 RESET METHOD Use OAT for head pressure control Automatic Faulty thermistor or wiring error Unit shutdown Stop use of economizer Unit shutdown Continue to run unit Use OAT changeover control Use differential dry bulb changeover Use Space temperature without offset Stop circuit Stop circuit Stop circuit Stop circuit Stop circuit Stop circuit Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Manual Manual Stop circuit Manual Compressor A2 shutdown Automatic Circuit A Low Saturated Suction Temperature Alert. Stop circuit Automatic A121 Circuit B Low Saturated Suction Temperature Alarm. Stop circuit Manual P121 Circuit B Low Saturated Suction Temp-Comp B2 Shutdown Compressor B2 shutdown Automatic T121 Circuit B Low Saturated Suction Temperature Alert. Stop circuit Automatic T122 T123 Circuit A High Saturated Suction Temperature Circuit B High Saturated Suction Temperature Stop circuit Stop circuit Manual Manual T126 Circuit A High Head Pressure Stop circuit Automatic Stop circuit Automatic Stop unit Stop unit Stop unit Stop unit Stop unit Stop unit Stop unit Stop gas heat Stop options on CEM Stop economizer & power exh Stop unit Stop demand limiting Stop static pressure reset/VFD Stop unit Close economizer, stop exhaust Stop unit Stop IAQ control Use a default value for IAQ Use software configured minimum Manual Manual Manual Manual Manual Manual Manual Automatic Automatic Automatic Automatic Automatic Automatic Manual Automatic Automatic Automatic Automatic Faulty remote input on CEM board Faulty thermistor or wiring error Faulty thermistor or wiring error Faulty thermistor or wiring error Faulty sensor or wiring error Faulty sensor or wiring error Faulty sensor or wiring error Faulty sensor, wiring error Faulty sensor, wiring error Faulty sensor, wiring error Faulty sensor, wiring error Low refrigerant charge Low refrigerant charge Low refrigerant charge, low airflow, dirty coil, broken fan belt, TXV problem Low refrigerant charge, low airflow, dirty coil, broken fan belt, TXV problem Low refrigerant charge, low airflow, dirty coil, broken fan belt, TXV problem Low refrigerant charge, low airflow, dirty coil, broken fan belt, TXV problem Low refrigerant charge, low airflow, dirty coil, broken fan belt, TXV problem Low refrigerant charge, low airflow, dirty coil, broken fan belt, TXV problem TXV problem, high load. TXV problem, high load. Dirty condenser, condenser fan failure, system overcharged Dirty condenser, condenser fan failure, system overcharged Incorrect compressor wiring External shutdown command Control Board failure, check lights Control Board failure, check lights Control Board failure, check lights Control Board failure, check lights Control Board failure, check lights Control Board failure, check lights Control Board failure, check lights Control Board failure, check lights Control Board failure, check lights Input failure, wiring error Input Failure, wiring error Wiring errors, board failures Sensor failure, wiring error Sensor failure, wiring error Sensor failure, wiring error Sensor failure, wiring error Automatic Input failure, wiring error T127 Circuit B High Head Pressure A140 A150 T153 A154 T155 A156 A157 A171 A172 A173 A174 T177 T178 A200 T210 T211 T220 T221 Reverse Rotation Detected Unit is in Emergency Stop Real Time Clock Hardware Failure Serial EEPROM Hardware Failure Serial EEPROM Storage Failure Error Critical Serial EEPROM Storage Failure Error A/D Hardware Failure Staged Gas Control Board Comm Failure Controls Expansion Module Comm Failure ECB1 Board Communication Failure ECB2 Board Communication Failure 4-20 MA Demand Limit Failure 4-20 MA Static Pressure Reset/VFD Fail Linkage Timeout Error - Communication Failure Building Pressure Transducer Failure Static Pressure Transducer Failure Indoor Air Quality Sensor Failure Outdoor Air Quality Sensor Failure T229 Economizer Minimum Position Override Input Failure 94 Table 114 — Alert and Alarm Codes (cont) ALARM OR ALERT NUMBER DESCRIPTION T300 Space Temperature Below Limit T301 Space Temperature Above Limit T302 Supply Temperature Below Limit T303 ACTION TAKEN BY CONTROL Stop cooling, but continue to heat Stop heating, but continue to cool RESET METHOD PROBABLE CAUSE Automatic Outdoor dampers stuck, no load Automatic High load, dampers open Continue to run unit Automatic Supply Temperature Above Limit Continue to run unit Automatic T304 Return Temperature Below Limit Continue to run unit Automatic T305 Return Temperature Above Limit Continue to run unit Automatic T308 Return Air Relative Humidity Below Limit Alert Automatic T309 Return Air Relative Humidity Above Limit Continue to run unit Automatic T310 T311 T312 T313 T314 Supply Duct Static Pressure Below Limit Supply Duct Static Pressure Above Limit Building Static Pressure Below Limit Building Static Pressure Above Limit IAQ Above Limit Continue to run unit Continue to run unit Continue to run unit Continue to run unit Continue to run unit Automatic Automatic Automatic Automatic Automatic Unit Shutdown Automatic Run power exhaust Run supply fan Run supply and exhaust fans Continue to run unit Stop unit Continue to run unit Automatic Automatic Automatic Automatic Automatic Automatic A404 Fire Shut Down Emergency Mode (fire-smoke) A405 A406 A407 T408 A409 T409 Evacuation Emergency Mode Pressurization Emergency Mode Smoke Purge Emergency Mode Dirty Air Filter Supply Fan Status Failure Supply Fan Status Failure T414 Loss of Communication with the Belimo Actuator T414 T414 T414 T414 Belimo Actuator Direction Error Belimo Actuator Failure Belimo Actuator Jammed Belimo Actuator Range Error R-W1 Jumper Must Be Installed to Run Heat in Service Test Thermostat Y2 Input ON without Y1 ON Thermostat W2 Input ON without W1 ON Thermostat Y and W Inputs ON Thermostat G Input OFF on a Call for Cooling Current Sensor Board Failure - A1 Current Sensor Board Failure - A2 Current Sensor Board Failure - B1 Current Sensor Board Failure - B2 Supply Air Temperature Sensor Failure Staged Gas Thermistor 1 Failure Staged Gas Thermistor 2 Failure Staged Gas Thermistor 3 Failure Staged Gas Leaving Air Temp Sum Total Failure Limit Switch Thermistor Failure T420 T421 T422 T423 T424 T500 T501 T502 T503 A700 T701 T702 T703 A704 T705 Axxx CEM IAQ OAT — — — — LEGEND Alarm Controls Expansion module Indoor Air Quality Outdoor Air Temperature Pxxx Txxx TXV VFD — — — — Close economizer Automatic Close economizer Attempt to close economizer Close economizer Close economizer Automatic Automatic Automatic Automatic Dampers open, check configuration setpoint Dampers open, check configuration setpoint Dampers open, check configuration setpoint Dampers open, check configuration setpoint Configuration error, or sensor error Dampers open, check configuration setpoint VFD problem, broken fan belt VFD problem, broken fan belt Exhaust issues, check setpoint Exhaust issues, check setpoint Damper or IAQ control issues Smoke detector switch or external switch Special fire mode control Special fire mode control Special fire mode control Dirty filter, switch setting Fan drive failure Fan drive failure, or sensor failure Calibrate economizer, economizer failure, wiring Motor direction switch wrong, wiring Motor failure Obstruction in damper Calibrate economizer No heat Automatic Add red wire jumpers Assume Y2 is Y1 Assume W2 is W1 Alert Turn fan on Stop compressor A1 Stop compressor A2 Stop compressor B1 Stop compressor B2 Stop staged gas heat Stop staged gas heat Stop staged gas heat Stop staged gas heat Stop staged gas heat Stop staged gas heat Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Thermostat wiring error Thermostat wiring error Thermostat issues Thermostat or wiring issues Faulty board or wiring Faulty board or wiring Faulty board or wiring Faulty board or wiring Faulty sensor or wiring error Faulty sensor or wiring error Faulty sensor or wiring error Faulty sensor or wiring error Faulty sensor or wiring error Faulty switch or wiring Pre-Alert Alert Thermostatic Expansion Valve Variable Frequency Drive size units there is one breaker per two compressors and on the 060 size units there is one breaker per compressor. • Wiring Error. A wiring error might not allow the compressor to start. To check out alerts 051, 052, 055 and 056: 1. Turn on the compressor in question using Service Test mode. If the compressor does not start, then most likely the problem is one of the following: HPS open, open internal protection, circuit breaker trip, incorrect safety wiring, or incorrect compressor wiring. 2. If the compressor does start verify it is rotating in the correct direction. For 48/50A2,A3,A4,A5 units: • Compressor internal overload protector is open. Internal overload protectors are used in the Copeland compressors in all units except size 60 ton units with voltages of 208/230-v, 380-v, and 575-v. • Compressor external overload protector (Kriwan module) has activated. The Copeland compressors in size 60 ton units with voltages of 208/230-v, 380-v, and 575-v use external overload protector modules that are mounted in the compressor wiring junction box. Temperature sensors embedded in the compressor motor windings are the inputs to the module. The module is powered with 120 vac from the units main control box. The module output is a normally closed contact that is wired in series with the compressor contactor coil. In a compressor motor overload condition, the contact opens de-energizing the compressor contactor. • Circuit breaker trip. The compressors are protected from short circuit by a breaker in the control box. On the 020-050 IMPORTANT: Prolonged operation in the wrong direction can damage the compressor. Correct rotation can be verified by a gage set and looking for a differential pressure rise on start-up. 95 The cause of the alert is usually a faulty thermistor, a shorted or open thermistor caused by a wiring error, or a loose connection. T072 (Evaporator Discharge Reset Sensor Failure) — If the unit is configured to use the remote EDT 4 to 20 mA reset input (ConfigurationEDT.RRES.S) and the sensor reading is less than 2 mA then the alert will occur. When this occurs the control will default to the internal set points. The sensor is connected to the optional CEM module. For this sensor to be used, the EDT 4 to 20 mA reset input (Configuration EDT.RRES.S) must be set to “enabled.” T073 (Outside Air Temperature Thermistor Failure) — This alert occurs when the outside air temperature sensor (TemperaturesAIR.TOAT) is outside the range –40 to 240 F (–40 to 116 C). Failure of this thermistor (TemperaturesAIR.TOAT) will disable any elements of the control which requires its use. Economizer control beyond the vent position and the calculation of mixed-air temperature for the sumZ algorithm will not be possible. This alert resets automatically. The cause of the alert is usually a faulty thermistor, a shorted or open thermistor caused by a wiring error, or a loose connection. T074 (Space Temperature Thermistor Failure) — This alert occurs when the space temperature sensor (Temperatures AIR.TSPT) is outside the range –40 to 240 F (–40 to 116 C). This alert will only occur if the unit is configured to use a space temperature sensor. Configuration is done through the Unit Control Type (ConfigurationUNITC.TYP) configuration. Failure of this thermistor (TemperaturesAIR.TSPT) will disable any elements of the control which requires its use. If the unit is configured for SPT 2 stage or SPT multi-stage operation and the sensor fails, no cooling or heating mode may be chosen. This alert resets automatically. The cause of the alert is usually a faulty thermistor in the T55, T56, or T58 device, a shorted or open thermistor caused by a wiring error, or a loose connection. T075 (Return Air Thermistor Failure) — This alert occurs when the return air temperature sensor (TemperaturesAIR.TRAT) is outside the range –40 to 240 F (–40 to 116 C). The RAT is standard on all units and is located in the return section near the auxiliary control box. This alert resets automatically. The cause of the alert is usually a faulty thermistor, a shorted or open thermistor caused by a wiring error, or a loose connection. Failure of this thermistor (TemperaturesAIR.TRAT) will disable any elements of the control which requires its use. Elements of failure include: • the calculation of mixed air temperature for sumZ control • the selection of a mode for VAV units • economizer differential enthalpy or dry bulb control • return air temperature supply air reset T076 (Outside Air Relative Humidity Sensor Failure) — This alert occurs when the outside air humidity sensor (InputsREL.HOA.RH) has a reading less than 2 mA. Failure of this sensor will disable any elements of the control which requires its use including economizer outdoor and differential enthalpy control. The OA.RH sensor is located in the economizer hood and is used for control of the economizer. The sensor is a loop powered 4 to 20 mA sensor. This alert resets automatically. The cause of the alert is usually a faulty sensor, a shorted or open sensor caused by a wiring error, or a loose connection. The unit must be configured to use the sensor through the Outside Air RH Sensor (ConfigurationECONORH.S) setting. T078 (Return Air Relative Humidity Sensor Failure) — This alert occurs when the return air humidity sensor (InputsREL.HRA.RH) has a reading less than 2 mA. Failure of this sensor (InputsREL.HRA.RH) will disable IMPORTANT: If the compressor starts, verify that the indoor and outdoor fans are operating properly. IMPORTANT: If the CS is always detecting current, then verify that the compressor is on. If the compressor is on, check the contactor and the relay on the MBB. If the compressor is off and there is no current, verify CS wiring and replace if necessary. IMPORTANT: Return to Normal mode and observe compressor operation to verify that compressor current sensor is working and condenser fans are energized after compressor starts. A051 (Circuit A, Compressor 1 Stuck On Failure) A052 (Circuit A, Compressor 2 Stuck On Failure) A055 (Circuit B, Compressor 1 Stuck On Failure) A056 (Circuit B, Compressor 2 Stuck On Failure) — Alarm codes 051, 052, 055, and 056 are for compressors A1, A2, B1, B2 respectively. These alarms occur when the current sensor (CS) detects current when the compressor should be off. When this occurs, the control turns off the compressor and logs a strike for the respective circuit. Use the scrolling marquee to reset the alarm. If the current sensor board reads ON while the compressor relay has been commanded OFF for a period of 4 continuous seconds, an alarm is generated. These alarms are only monitored for a period of 10 seconds after the compressor relay has been commanded OFF. This is done to facilitate a service technician forcing a relay to test a compressor. In addition, if a compressor stuck failure occurs and the current sensor board reports the compressor and the request off, certain diagnostics will take place. 1. If any of the 4 compressors are diagnosed as stuck on and the current sensor board is on and the request is off, the control will request the supply fan which will automatically start building airflow control. Condenser fans will also be commanded on to maintain normal head pressure. 2. Heating will be disabled while any one of the compressors has this problem. The possible causes are: • welded contactor • frozen compressor relay on MBB To check out alarms 051, 052, 055, and 056: 1. Place the unit in Service Test mode. All compressors should be off. 2. Verify that there is not 24 v at the contactor coil. If there is 24 v at the contactor, check relay on MBB and wiring. 3. Check for welded contactor. 4. Verify CS wiring. 5. Return to Normal mode and observe compressor operation to verify that compressor current sensor is working and condenser fans are energized after compressor starts. T064 (Circuit A Saturated Condensing Thermistor Failure) T065 (Circuit B Saturated Condensing Thermistor Failure) — Alert codes 064 and 065 are for circuits A and B, respectively. This alert code is for 48/50AJ,AK,AW,AY units only. These alerts occur when the saturated condensing temperatures (TemperaturesREF.TSCT.A and SCT.B) are outside the range –40 to 240 F (–40 to 116 C). When this occurs, the control uses the outdoor temperature (OAT) to control the outdoor fans. The control will default to control based on the OAT sensor and will turn on OFC.B when the ambient is above 65 F and off when the ambient is below 50 F. If the SCT and OAT sensors have all failed then the control should turn on OFC.B when compressors are on. 96 any elements of the control which requires its use including economizer differential enthalpy control. The RA.RH sensor is located in the return air section near the auxiliary control box. The sensor is a loop powered 4 to 20 mA sensor. This alert resets automatically. The cause of the alert is usually a faulty sensor, a shorted or open sensor caused by a wiring error, or a loose connection. The unit must be configured to use the sensor through the Outside Air RH Sensor (ConfigurationUNITSENSRRH.S) setting. T082 (Space Temperature Offset Sensor Failure) — If the unit is configured to use a space temperature sensor and is using a T56 sensor with an offset potentiometer, then the alert will occur if the potentiometer is outside the allowable range. The control will default to the software applicable set point because there is no offset available that may be applied to space temperature. The alert will automatically clear. The unit must be configured for one of the SPT control options through the Unit Control Type (ConfigurationUNITC.TYP) configuration. T090 (Circuit A Discharge Pressure Transducer Failure) T091 (Circuit B Discharge Pressure Transducer Failure) — Alert codes 090, and 091 are for circuits A and B respectively. These alerts occur when the unit is configured for pressure transducers (ConfigurationUNITDP.XR) and the pressure is outside the range 0.0 to 667.0 psig. A circuit cannot run when this alert is active. Use the scrolling marquee to reset the alert. The cause of the alert is usually a faulty transducer, faulty 5v power supply, or a loose connection. Although the software supports this option, it is not possible at the time of the writing of this specification to order the optional discharge pressure transducers. T092 (Circuit A Suction Pressure Transducer Failure) T093 (Circuit B Suction Pressure Transducer Failure) — Alert codes 092, and 093 are for circuits A and B respectively. These alerts occur when the pressure is outside the following ranges: 0.5 to 134.5 psig when SP.XR=0, 0.0 to 200.0 psig when SP.XR=1, and 0.0 to 420.0 psig on all 48/50A2,A3,A4,A5 units. A circuit cannot run when this alert is active. Use the scrolling marquee to reset the alert. The cause of the alert is usually a faulty transducer, faulty 5 v power supply, or a loose connection. T110 (Circuit A Loss of Charge) T111 (Circuit B Loss of Charge) — Alert codes 110, and 111 are for circuits A, and B respectively. These alerts occur when the compressor is OFF and the suction pressure is less than 5 psig for 48/50AJ,AK,AW,AY units or 18 psig for 48/50A2, A3,A4,A5 units and the OAT is above –5 F for 1 continuous minute. The alert will automatically clear when the suction pressure transducer reading is valid and greater than 15 psig for 48/50AJ,AK,AW,AY units or 54 psig for 48/50A2,A3,A4,A5 units. The cause of the alert is usually low refrigerant pressure or a faulty suction pressure transducer. P120 (Circuit A Low Saturated Suction Temperature — Compressor A2 Shutdown) T120 (Circuit A Low Saturated Suction Temperature Alert) A120 (Circuit A Low Saturated Suction Temperature Alarm) P121 (Circuit B Low Saturated Suction Temperature — Compressor B2 Shutdown) T121 (Circuit B Low Saturated Suction Temperature Alert) A121 (Circuit B Low Saturated Suction Temperature Alarm) — This alert/alarm is used to keep the evaporator coils from freezing and the saturated suction temperature above the low limit for the compressors. There will be a start-up delay if the outside-air temperature is too low. When the outdoor ambient is below 60 F, during initial start-up, saturated suction temperature will be ignored for a period of 5 minutes. When TemperaturesREF.TSSTA or TemperaturesREF.TSSTB is less than 20 F for 4 minutes, less than 10 F for 2 minutes, less than 0° F for 1 minute or less than –20 F for 20 seconds continuously, the second compressor of the affected circuit, if it exists, will be shut down with a local alert (P120, P121) and a 10-minute timeguard will be added to the compressor. If saturated suction temperature continues to be less than 20 F for 4 minutes, less than 10 F for 2 minutes, less than 0° F for 1 minute or less than –20 F for 20 seconds continuously then compressor no. 1 will be shut down and then an alert or alarm will be issued. This failure follows a 3 strike methodology whereby the first two times a circuit goes down entirely, an alert will be generated which keeps the circuit off for 15 minutes before allowing the circuit to try again. The third time this happens, an alarm will be generated which will necessitate a manual reset to get the circuit back running. It is important to note that a “strike” is called out only if all compressors in the circuit are off at the time of alert/alarm. To prevent nuisance alerts, P120 and P121 show up in the alarm history and locally at the display but are not broadcast to the network. To recover from these alerts, a 10-minute holdoff timer must elapse and the saturated suction temperature must rise above 29.32 F. If recovery occurs, staging will be allowed on the circuit again. Again, a “strike” is tied to the circuit going off entirely, not reducing capacity and recovering. Therefore it is possible that multiple P120 or P121 alerts may be stored in alarm history but not broadcast. If there are 1 or 2 strikes on the circuit and the circuit recovers for a period of time, it is possible to clear out the strikes thereby resetting the strike counter automatically. The control must have saturated suction temperature greater than or equal to 34 F for 60 minutes in order to reset the strike counters. T122 (Circuit A High Saturated Suction Temperature) T123 (Circuit B High Saturated Suction Temperature) — Alert codes 122 and 123 occur when compressors in a circuit have been running for at least 5 to 30 minutes (Configuration COOLH.SST). On 48/50AJ,AK,AW,AY units, this alert code occurs if the circuit saturated suction temperature is greater than 60 F. On 48/50A2,A3,A4,A5 units, this alert code occurs if the circuit saturated suction temperature is greater than 65 F when one compressor is running or 60 F when two compressors are running. For all units, the high saturated suction alert is generated and the circuit is shut down. Alert code 122 is for circuit A and 123 for circuit B. T126 (Circuit A High Head Pressure) T127 (Circuit B High Head Pressure) — Alert codes 126, and 127 are for circuits A and B respectively. On 48/ 50AJ,AK,AW,AY units, these alerts occur when the appropriate saturated condensing temperature is greater 145 F. Prior to the alert, the control will shut down one compressor on a circuit if that circuit's saturated condensing temperature is greater than 140 F. If SCT continues to rise to greater than 145 F, the alert will occur and the circuit's remaining compressor will shut down. On 48/50A2,A3,A4,A5 units, these alerts occur when the appropriate saturated condensing temperature is greater than 150 F. Prior to the alert, the control will shut down one compressor on a circuit if that circuit's saturated condensing temperature is greater than 145 F. If SCT continues to rise to greater than 150 F, the alert will occur and the circuit's remaining compressor will shut down. The cause of the alarm is usually an overcharged system, high outdoor ambient temperature coupled with dirty outdoor coil, plugged filter drier, or a faulty high-pressure switch. The alert will clear automatically or when the OAT drops 5° F from the time of the alert. A140 (Reverse Rotation Detected) — A test is made once, on power up, for suction pressure change on the first activated circuit. The unit control determines failure is as follows: The suction pressure of both circuits is sampled 5 seconds before the compressor is brought on, right when the 97 T177 (4-20 mA Demand Limit Failure) — This alert indicates a problem with the optional remote 4 to 20 mA demand limit signal (Inputs4-20DLM.M) that is connected to the CEM module (if the signal reads less than 2 mA). If this occurs, then demand limiting will be disabled. The unit must be configured for 4 to 20 mA Demand Limiting using the Demand Limit Select (ConfigurationDMD.LDM.L.S). T178 (4-20 mA Static Pressure Reset/VFD Failure) — If this transducer fails (if the signal reads less than 2 mA on the input of the CEM module), and the unit is configured to perform static pressure reset or remote control of the supply fan VFD with this transducer, no static pressure reset or VFD control will be performed and an alert will be generated. Recovery is automatic. Reason for error is either a faulty sensor, wiring error, or damaged input on the CEM control board. A200 (Linkage Timeout Error — Comm Failure) — If linkage is established via the CCN with ComfortID™ terminals, a 5-minute timeout on loss of communication will be monitored. If 5 minutes expires since the last communication from a VAV Linkage Master, the unit will remove the link and flag the alert. When the rooftop looses its link, the temperature and set points are derived locally. Recovery is automatic on re-establishment of communications. Reason for failure may be wiring error, too much bus activity, or damaged 485 drivers. T210 (Building Pressure Transducer Failure) — The building pressure transducer (PressuresAIR.PBP) fails if the signal from the 4 to 20 mA building pressure transducer (used to control the power exhaust fans and the building pressure) is below 2 mA. If the alert occurs, then the economizer will be closed and the power exhaust fans turned off. This alert will automatically reset. Check the building pressure transducer and sensor tubing. The sensor is located in the auxiliary control box. The alert will automatically reset. T211 (Static Pressure Transducer Failure) — The static pressure transducer (PressuresAIR.PSP) fails if the signal from the 4 to 20 mA static pressure transducer (used to control the VFD speed) is below 2 mA. This failure will cause the unit to stop due to the potential damage that could occur due to over-pressurization. Check the pressure transducer and sensor tubing. The sensor is located in the auxiliary control box. The alert will automatically reset. T220 (Indoor Air Quality Sensor Failure) — The indoor air quality sensor (InputsAIR.QIAQ) fails if the signal from the 4 to 20 mA sensor is below 2 mA. If the indoor air quality sensor fails, demand control ventilation is not possible. The control defaults to the maximum vent position. Recovery is automatic. Reason for error is either a faulty sensor, wiring error, or damaged input on the MBB control board. T221 (Outdoor Air Quality Sensor Failure) — The indoor air quality sensor (InputsAIR.QOAQ) fails if the signal from the 4 to 20 mA sensor is below 2 mA. If the outdoor air quality sensor fails, OAQ defaults to 400 ppm and demand control ventilation will continue. Recovery is automatic. Reason for error is either a faulty sensor, wiring error, or damaged input on the CEM control board. T229 (Economizer Minimum Position Override Input Failure) — If the unit is configured to use the remote position override for the economizer and the input Econo Min. Pos. Override (ConfigurationIAQAQ.SPIQ.O.P) input 4 to 20 mA reading is less than 2 mA then an alert will occur and the default software minimum position will be used for the economizer. The alert will automatically reset. T300 (Space Temperature Below Limit) — If the space temperature is below the configurable SPT Low Alert Limits (occupied [ConfigurationALLMSP.L.O] for 5 minutes or unoccupied [ConfigurationALLMSP.L.U] for 10 minutes), then an alert will be broadcast. The alert will automatically reset. compressor is brought on and 5 seconds afterwards. The rate of suction pressure change from 5 seconds before the compressor is brought on to when the compressor is brought on is calculated. Then the rate of suction pressure change from when the compressor is brought on to 5 seconds afterwards is calculated. With the above information, the test for reverse rotation is made. If the suction pressure change 5 seconds after compression is greater than the suction pressure change 5 seconds before compression – 1.25, then there is a reverse rotation error. This alarm will disable mechanical cooling and will require a manual reset. This alarm may be disabled once the reverse rotation check has been verified by setting Configuration COOLREV.R = Yes. A150 (Unit is in Emergency Stop) — If the fire safety input condition occurs to indicate a fire or smoke condition, then Alarm code 150 will occur and the unit will be immediately stopped. Through separate inputs the unit can be put into purge, evacuation, and pressurization. This requires a manual reset. If the CCN point name “EMSTOP” in the System table is set to emergency stop, the unit will shut down immediately and broadcast an alarm back to the CCN indicating that the unit is down. This alarm will clear when the variable is set back to “enable.” T153 (Real Time Clock Hardware Failure) — A problem has been detected with the real timeclock on the MBB. Try resetting the power and check the indicator lights. If the alert continues, the board should be replaced. A154 (Serial EEPROM Hardware Failure) — A problem has been detected with the EEPROM on the MBB. Try resetting the power and check the indicator lights. If the alarm continues, the board should be replaced. T155 (Serial EEPROM Storage Failure Error) — A problem has been detected with the EEPROM storage on the MBB. Try resetting the power and check the indicator lights. If the alert continues, the board should be replaced. A156 (Critical Serial EEPROM Storage Failure Error) — A problem has been detected with the EEPROM storage on the MBB. Try resetting the power and check the indicator lights. If the alarm continues, the board should be replaced. A157 (A/D Hardware Failure) — A problem has been detected with A/D conversion on the boards. Try resetting the power and check the indicator lights. If the alarm continues, the board should be replaced. A171 (Staged Gas Control Board Comm Failure) — This alarm indicates that there are communications problems with the staged gas heat control board, which is located in the gas section on units equipped with staged gas heat. If this alarm occurs, the staged gas heat will be disabled. The alarm will automatically reset. A172 (Controls Expansion Module Comm Failure) — This alarm indicates that there are communications problems with the controls expansion board. All functions performed by the CEM will stop, which can include demand limit, reset, fire control modes, and the fan status switch. The alarm will automatically reset. A173 (ECB1 Board Communication Failure) — This alarm indicates that there are communications problems with the economizer control board. This will result in the economizer and the power exhaust not working and the dampers to be fully closed. The exhaust fans will stop. The alarm will automatically reset. A174 (ECB2 Board Communication Failure) — This alarm indicates that there are communications problems with the ECB2 which controls the VAV unit indoor fan inverter speed and hot gas bypass on CV and VAV units. Because the control of the fan is critical to unit operation, the unit will be stopped. The alarm will automatically reset. 98 configured using the BP HI Alert Limit (Configuration ALLMBP.H). If the measured pressure (PressuresAIR.PBP) is above the limit for 5 minutes, then the alert will occur. T314 (IAQ Above Limit) — If the unit is configured to use an CO2 sensor and the level (InputsAIR.QIAQ) is above the configurable IAQ High Alert Limit (Configuration ALLMIAQ.H) for 5 minutes then the alert will occur. The unit will continue to run and the alert will automatically reset. A404 (Fire Shutdown Emergency Mode) — This alarm occurs when the fire shutdown input is active (either open or closed depending upon its configuration). If the fire shutdown input is energized (fire shutdown is in effect), or if two fire smoke modes are incorrectly energized at the same time, a fire shutdown mode will occur. This is an emergency mode requiring the complete shutdown of the unit. Recovery is automatic when the inputs are no longer on. This alarm is usually caused by an auxiliary device that is trying to shut down the unit (e.g., smoke detector). The input for Fire Shutdown is at InputsFIREFSD. The switch logic configuration for this switch input can be found at variable ConfigurationSW.LGFSD.L. Verify that the configuration is set correctly, verify the wiring and auxiliary device. This alarm resets automatically. A405 (Evacuation Emergency Mode) — Unit has been placed in the fire evacuation mode by means of the external command for evacuation (InputsFIREEVAC). If the evacuation input on the CEM is energized, an evacuation mode occurs which flags an alarm. This mode attempts to lower the pressure of the space to prevent smoke from moving into another space. This is the reverse of the Pressurization mode. Closing the economizer, opening the return-air damper, turning on the power exhaust, and shutting down the indoor fan will decrease pressure in the space. Recovery is automatic when the input is no longer on. A406 (Pressurization Emergency Mode) — Unit has been placed in the fire pressurization mode by means of the External command for pressurization (InputsFIREPRES). If the pressurization input on the CEM is energized, a pressurization mode occurs which flags an alarm. This mode attempts to raise the pressure of a space to prevent smoke infiltration from another space. The space with smoke should be in an Evacuation mode attempting to lower its pressure. Opening the economizer, closing the return-air damper, shutting down power exhaust, and turning the indoor fan on will increase pressure in the space. Recovery is automatic when the input is no longer on. A407 (Smoke Purge Emergency Mode) — Unit has been placed in the fire pressurization mode by means of the external command for pressurization (InputsFIREPURG). If the smoke purge input on the CEM is energized, a smoke purge mode occurs which flags an alarm. This mode attempts to draw out smoke from the space after the emergency condition. Opening the economizer, closing the return-air damper, and turning on both the power exhaust and indoor fan will evacuate smoke and bring in fresh air. Recovery is automatic when the input is no longer on. T408 (Dirty Air Filter) — If no dirty filter switch is installed, the switch will read “clean filter” all the time. Therefore the dirty filter routine runs continuously and diagnoses the input. Because of the different possible times it takes to generate static pressure, this routine waits 2 minutes after the fan starts before the dirty filter switch is monitored. If the dirty filter switch reads “dirty filter” for 2 continuous minutes, an alert is generated. No system action is taken. This is a reminder that it is time to change the filters in the unit. Recovery from this alert is through a clearing of all alarms (manual) or after the dirty filter switch reads clean for 30 continuous seconds (automatic). T301 (Space Temperature Above Limit) — If the space temperature is above the configurable SPT High Alert Limits (occupied [ConfigurationALLMSP.H.O] for 5 minutes or unoccupied [ConfigurationALLMSP.H.U] for 10 minutes), then an alert will be broadcast. The alert will automatically reset. T302 (Supply Temperature Below Limit) — If the supply-air temperature measured by the supply temperature sensor is below the configurable SAT LO Alert Limit/Occ (ConfigurationALLMSA.L.O) for 5 minutes or the SAT LO Alert Limit/Unocc (ConfigurationALLMSA.L.U) for 10 minutes, then an alert will be broadcast. T303 (Supply Temperature Above Limit) — If the supply temperature is above the configurable SAT HI Alert Limit Occ (ConfigurationALLMSAH.O) for 5 minutes or the SAT HI Alert Limit/Unocc (ConfigurationALLMSA.H.U) for 10 minutes, then an alert will be broadcast. The alert will automatically reset. T304 (Return Air Temperature Below Limit) — If the returnair temperature measured by the RAT sensor is below the configurable RAT LO Alert Limit/Occ (Configuration ALLMRA.L.O) for 5 minutes or RAT HI Alert Limit/Occ (ConfigurationALLMRA.L.U) for 10 minutes, then an alert will be broadcast. T305 (Return Air Temperature Above Limit) — If the returnair temperature is below the RAT HI Alert Limit/Occ (ConfigurationALLMRA.H.O) for 5 minutes or RAT HI Alert Limit/Occ (ConfigurationALLMRA.H.U) for 10 minutes, then an alert will be broadcast. The alert will automatically reset. T308 (Return Air Relative Humidity Below Limit) — If the unit is configured to use a return air relative humidity sensor through the Return Air RH Sensor (Configuration UNITSENSRRH.S) setting, and the measured level is below the configurable RH Low Alert Limit (Configuration ALLMR.RH.L) for 5 minutes, then the alert will occur. The unit will continue to run and the alert will automatically reset. T309 (Return Air Relative Humidity Above Limit) — If the unit is configured to use a return air relative humidity sensor through the Return Air RH Sensor (Configuration UNITSENSRRH.S) setting, and the measured level is above the configurable RH High Alert Limit (Configuration ALLMR.RH.H) for 5 minutes, then the alert will occur. Unit will continue to run and the alert will automatically reset. T310 (Supply Duct Static Pressure Below Limit) — If the unit is a VAV unit with a supply duct pressure sensor and the measured supply duct static pressure (Pressures AIR.PSP) is below the configurable SP Low Alert Limit (ConfigurationALLMSP.L) for 5 minutes, then the alert will occur. The unit will continue to run and the alert will automatically reset. T311 (Supply Duct Static Pressure Above Limit) — If the unit is a VAV unit with a supply duct pressure sensor and the measured supply duct static pressure (Pressures AIR.PSP) is above the configurable SP Low Alert Limit (ConfigurationALLMSP.H) for 5 minutes, then the alert will occur. The unit will continue to run and the alert will automatically reset. T312 (Building Static Pressure Below Limit) — If the unit is configured to use a VFD controlled power exhaust or a modulating power exhaust then a building static pressure limit can be configured using the BP Low Alert Limit (Configuration ALLMBP.L). If the measured pressure (PressuresAIR.PBP) is below the limit for 5 minutes then the alert will occur. T313 (Building Static Pressure Above Limit) — If the unit is configured to use a VFD controlled power exhaust or a modulating power exhaust then a building static pressure limit can be 99 on, the software will behave as if Y1 and Y2 are both on. When Y2 turns off, the software will behave as if Y1 and Y2 are both Off. This alert resets automatically when Y1 is turned on. T422 (Thermostat W2 Input On without W1 On) — This alert occurs in Thermostat Mode when W2 is energized and W1 is not. Verify thermostat and thermostat wiring. When W2 turns on, the software will behave as if W1 and W2 are both on. When W2 turns off, the software will behave as if W1 and W2 are both off. This alert resets automatically when W1 is turned on. T423 (Thermostat Y and W Inputs On) — This alert occurs in Thermostat Mode when Y1 or Y2 is energized simultaneously with W1 or W2. Verify thermostat and thermostat wiring. The software will enter either the cooling or heating mode depending upon which input turned on first. This alert resets automatically when Y1 and Y2 are not on simultaneously with W1 and W2. T424 (Thermostat G Input Off On a Cooling Call) — This alert occurs in Thermostat Mode when the fan is not requested (G = ON) during cooling (Y1 or Y2 = ON). Verify thermostat and thermostat wiring. T500 (Current Sensor Board Failure – A1) T501 (Current Sensor Board Failure – A2) T502 (Current Sensor Board Failure – B1) T503 (Current Sensor Board Failure – B2) — Alert codes 500, 501, 502, and 503 are for compressors A1, A2, B1, and B2 respectively. These alerts occur when the output of the current sensor (CS) is a constant high value. These alerts reset automatically. If the problem cannot be resolved and the CS board must be replaced, the CS board can be temporarily disabled while securing a replaced board. A CS board is disabled by setting ConfigurationCOOLCS.A1, CS.A2, CS.B1 or CS.B2 to Disable. If the current sensor board malfunctions or is not properly connected to its assigned digital input, an alert will be generated. It takes 2 to 4 seconds to log the alert. If the alert is logged, it stays for a minimum of 15 seconds to provide the application a reasonable time to catch the failure. Compressors will be not be inhibited by this failure. Recovery is automatic. Reason for failure may be a faulty current sensor board, incorrect wiring, or a damaged input on the MBB control board. A700 (Supply Air Temperature Sensor Failure) — This alarm indicates a failure of the sensor supply air temperature sensor or the leaving air temperature sensor (if using hydronic heat). This alarm occurs when the temperature sensor (TemperaturesAIR.TSAT) is outside the range –40 to 240 F (–40 to 116 C). This alarm resets automatically. The cause of the alarm is usually a faulty thermistor, a shorted or open thermistor caused by a wiring error, or a loose connection. T701 (Staged Gas 1 Thermistor Failure) T702 (Staged Gas 2 Thermistor Failure) T703 (Staged Gas 3 Thermistor Failure) — If any of the staged gas thermistors (TemperaturesAIR.TS.G.L1-3) fails, an alert will be generated and the remaining thermistors will be averaged together (TemperaturesAIR.TS.G.LS) without the failed thermistor. Recovery is automatic. Reason for failure may be incorrect wiring, faulty thermistor, or a damaged input on the staged gas control board (SCB). A704 (Staged Gas Leaving Air Temperature Sum Total Failure) — If all three staged gas thermistors (TemperaturesAIR.TS.G.L1-3) fail (the sensor is outside the range of –40 F to 240 F), staged gas will be shut down and this alarm will be generated. Recovery is automatic. Reason for failure may be faulty wiring, faulty thermistors, or damaged inputs on the staged gas control board (SCB). Because the Dirty Air Filter switch can be configured normally opened or closed, the switch might be open or closed. The configuration for this switch input can be found at variable ConfigurationSW.LGSFS.L. Verify that the configuration is set correctly. Verify the wiring and filter status switch. The hose should be connected to the low side of the switch. This alert resets automatically. The dirty filter switch is enabled at ConfigurationUNITSENSFLT.S. A409 (Supply Fan Commanded On, Sensed Off Failure) A409 (Supply Fan Commanded Off, Sensed On Failure) T409 (Supply Fan Commanded On, Sensed Off Failure) T409 (Supply Fan Commanded Off, Sensed On Failure) — Both the alert and the alarm refer to the same failure. The only difference between the alarm and alert is that in the case where the supply fan status configuration to shut down the unit is set to YES (ConfigurationUNITSFS.S), the alarm will be generated AND the unit will be shut down. It is possible to configure ConfigurationUNITSSFS.M to either a switch or to monitor a 0.2-in. wg rise in duct pressure if the unit is VAV with duct pressure control. The timings for failure for both are the same and are illustrated in the following table: UNIT TYPE/MODE CV (no gas heat) CV (gas heat) VAV (IGV/no gas heat) VAV (VFD/no gas heat) VAV (IGV/gas heat) VAV (VFD/gas heat) MINIMUM ON TIME 30 seconds 2 minutes 2 minutes 1 minute 4 minutes 3 minutes MINIMUM OFF TIME 1 minute 4 minutes 4 minutes 1 minute 4 minutes 4 minutes Recovery is manual. Reason for failure may be a broken fan belt, failed fan relay or failed supply fan status switch. T414 (Loss of Communication with Belimo Actuator) — The Belimo economizer motor is a digital controlled motor. The ComfortLink™ controls can monitor the status of the motor. If there is a problem, this alert will occur. The control will attempt to close the economizer dampers. T414 (Belimo Actuator Direction Error) — This alert occurs when the economizer damper direction switch is in the wrong position. The direction switch should be in the clockwise position and the actuator should be mounted so that the CW face of the actuator is accessible. Correct if necessary. This alert clears automatically. T414 (Belimo Actuator Failure) — This alert occurs when the commanded damper position is changing too rapidly. This alert resets automatically. T414 (Belimo Actuator Jammed) — This alert occurs when the control software has detected that the damper is stuck. Check the mechanical actuation of the dampers. T414 (Belimo Actuator Range Error) — This alert occurs when the economizer range of motion is less than 90 degrees. Initiate economizer calibration (Service TestINDP E.CAL) using the Service Test menu. T420 (R-W1 Jumper Must be Installed to Run Heat in Service Test) — This alert occurs when a request for a heat output has occurred yet the W1 input is not high. A jumper must be installed between R and W1 when trying to test heat in Service Test. The alert will clear when Service Test is exited or if another Service Test mode is selected. Remove jumper when done using Service Test if the unit is operating with a thermostat. The jumper should only be left in place if the unit is operating with a space temperature sensor. T421 (Thermostat Y2 Input On without Y1 On) — This alert occurs in Thermostat Mode when Y2 is energized and Y1 is not. Verify thermostat and thermostat wiring. When Y2 turns 100 VAV BOARD (ECB2) — The VAV board (which is the same hardware as the ECB1) is used to control the supply fan on VAV units. See Fig. 27. It sends a 4 to 20 mA signal to the VFD based on a supply duct pressure sensor connected to the board. The board also accepts a signal from another pressure sensor that monitors building pressure and controls the operation of the optional modulating power exhaust motors. The board will also be used on CV units with the optional building pressure control feature and modulating power exhaust. This board is also used to control a digitally controlled hot gas bypass solenoid with an integral orifice for use in low load applications. This board is located in the auxiliary control box. Input and output assignments are summarized in Table 117. STAGED GAS HEAT BOARD (SCB) — When optional staged gas heat is used on CV and VAV units, the SCB board is installed and controls operation of the gas valves. See Fig. 28. The SCB also provides additional sensors for monitoring of the supply-air temperature. This board is located in the gas heat section of the unit. The inputs and outputs are summarized in Table 118. CONTROL EXPANSION MODULE (CEM) — The optional CEM (also available as an accessory) is used to accept inputs for additional sensors or control sequence switches, including: • smoke control mode field switches • VAV Supply Air Temperature Set Point reset using an external 4 to 20 mA signal • outdoor air CO2 sensor (for supply duct pressure reset using an eternal 4 to 20 mA signal) • external fan status pressure switch input (CV units) • demand limit sequence proportional signal or discrete switches The CEM board is located in the main control box. See Fig. 29. The inputs and outputs are summarized in Table 119. INTEGRATED GAS CONTROL (IGC) — One IGC is provided with each bank of gas heat exchangers (2 used on the size 020-050 units and 3 on size 051 and 060 units). The IGC controls the direct spark ignition system and monitors the rollout switch, limit switches, and induced-draft motor Hall Effect switch. The IGC is equipped with an LED (lightemitting diode) for diagnostics. See Table 120. COMPRESSOR PROTECTION BOARD (CS) — This board monitors the status of the compressor by sensing the current flow to the compressors and then provides digital status signal to the MBB. T705 (Limit Switch Thermistor Failure) — A failure (the sensor is outside the range of –40 F to 240 F) of this thermistor (TemperaturesAIR.TS.G.LM) will cause an alert to occur and a disabling of the limit switch monitoring function for the staged gas control board (SCB). Recovery is automatic. Reason for failure may be due to faulty wiring, a faulty thermistor, or a damaged input on the staged gas control board (SCB). MAJOR SYSTEM COMPONENTS General — The 48/50A Series package rooftop units with electric cooling and with gas heating (48A units) or electric cooling and electric heating (50A units) contain the ComfortLink™ electronic control system that monitors all operations of the rooftop. The control system is composed of several components as listed below. See Fig. 15-23 for typical control and power component schematics. Figures 24 and 25 show the layout of the control box, unit, and thermistor and transducer locations. Factory-Installed Components MAIN BASE BOARD (MBB) — See Fig 26. The MBB is the center of the ComfortLink control system. The MBB contains the major portion of the operating software and controls the operation of the unit. The MBB has 22 inputs and 11 outputs. See Table 115 for the inputs and output assignments. The MBB also continuously monitors additional data from the optional ECB1, ECB2, SCB, and CEM boards through the LEN communications port. The MBB also interfaces with the Carrier Comfort Network® system through the CCN communications port. The board is located in the main control box. ECONOMIZER BOARD (ECB1) — The ECB1 controls the economizer actuator and the power exhaust fans. The ECB1 operates the economizer motor using a digital communication signal that also provides status and diagnostics for the economizer motor. See Fig. 27. The ECB1 also controls the operation of the power exhaust motors and provides up to 6 stages of digitally sequenced power exhaust either based on the economizer motor position or the building pressure. The board has 4 inputs and 6 outputs. Additionally, ECB1 provides an output that will send a 4 to 20 mA signal to a field-installed VFD power exhaust accessory. Details can be found in Table 116. The ECB1 board is located in an auxiliary box located at the end of the unit behind the filter access door. The board also contains a second LEN port than can be used with the accessory Navigator™ display. 101 ~ ~~ ~~ ~~ ~ RED JUMPER WIRE MUST BE ADDED BETWEEN R AND W1 FOR UNITS EQUIPPED WITH HEAT IN NON-THERMOSTAT APPLICATIONS Fig. 15 — Typical Main Control Box Wiring Schematic (48/50AJ,AK,AW,AY Units) a48-8355 102 TO NEXT PAGE ~ ~ ~ ~~ ~~~ Fig. 15 — Typical Main Control Box Wiring Schematic (48/50AJ,AK,AW,AY Units) (cont) a48-8355 103 a48-8355 104 Fig. 16 — Typical Main Control Box Wiring Schematic (48/50A2,A3,A4,A5 Units) ~ ~ ~ ~~ ~ ~~ ~ ~ ~ TO NEXT PAGE ~~~ A48-7294 Fig. 17 — Typical Auxiliary Control Box Wiring Schematic 105 ~ ~ ~~ ~~~ ~~~~ ~~ ~ a48-8356 Fig. 17 — Typical Auxiliary Control Box Wiring Schematic (cont) 106 a48--8357 Fig. 18 — Typical 2 Stage Gas Heat Wiring Schematic (Size 051 and 060 Units Shown) 107 ~~ TO NEXT PAGE A48-7296 Fig. 19 — Typical Staged Gas Heat Wiring Schematic (Size 051 and 060 Units Shown) 108 ~~ A48-8358 Fig. 19 — Typical Staged Gas Heat Wiring Schematic (Size 051 and 060 Units Shown) (cont) 109 a50-8228 110 Fig. 20 — Typical Electric Heat Control Schematic — (50 Series Size 051 and 060 Units Shown) TO NEXT PAGE A48-7298 Fig. 21 — Typical Power Schematic (48/50AJ,AK,AW,AY051 and 060 Units Shown) 111 FROM PREVIOUS PAGE a48-8360 Fig. 21 — Typical Power Schematic (48/50AJ,AK,AW,AY051 and 060 Units Shown) (cont) 112 113 Fig. 22 — Typical Power Schematic (48/50A2,A3,A4,A5060 Unit Shown) a48-8361 114 Fig. 23 — Typical Controls Option Wiring Schematic SW2 OR DEHUMIDIFY SWITCH SW1 a48-8362 115 Fig. 24 — Typical Small Chassis Component Location (Size 020-035 Units) A48-7302 116 Fig. 25 — Typical Large Chassis Component Locations (Size 036-060 Units) LEGEND AND NOTES FOR FIG. 15-25 LEGEND A AUX B BP C CAP CB CCB CCH CCN CEM COMP CR CS CSB DP DPT DS ECB-1 ECB-2 EDT FIOP FS FU GND HC HGBP HIR HPS HR HS IAQ IDF IDM IFC IFCB IFM IGC IP LAT LEN LS MBB MGV NEC OARH OAT OFC OFM PEC PEM — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — PL RARH RAT RLA RLY RS SCB SCT SDU SST T-55 T-56 TB TRAN VAV VFD Circuit A Auxiliary Contact Circuit B Building Pressure Transducer Contactor, Compressor Capacitor Circuit Breaker Control Circuit Breaker Crankcase Heater Carrier Comfort Network® Controls Expansion Module Compressor Motor Control Relay Compressor Safety Compressor Current Sensing Board Duct Pressure Sensor Discharge Pressure Transducer Disconnect Switch Economizer Control Board Building and Supplier Air Control Board Evaporator Discharge Air Temperature Factory-Installed Option Flame Sensor Fuse Ground Heat Contactor Hot Gas Bypass Heat Interlock Relay High Pressure Switch Heat Relay Hall Effect Induced Draft Motor Switch Indoor Air Quality Induced Draft Fan Induced Draft Motor Indoor Fan Contactor Indoor Fan Circuit Breaker Indoor Fan Motor Integrated Gas Control Board Internal Compressor Protector Staged Gas Temperature Sensor Local Equipment Network Limit Switch Main Base Board Main Gas Valve National Electrical Code Outdoor Air Relative Humidity Outdoor Air Temperature Sensor Outdoor Fan Contactor Outdoor Fan Motor Power Exhaust Contactor Power Exhaust Motor — — — — — — — — — — — — — — — — Plug Return Air Relative Humidity Return Air Temperature Sensor Rated Load Amps Relay Rollout Switch Staged Gas Heat Control Board Saturated Condensing Temperature Sensor Scrolling Marquee Display Saturated Suction Temperature Sensor Room Temperature Sensor Room Temperature Sensor with Setpoint Terminal Block Transformer Variable Air Volume Variable Frequency Drive Terminal Block Terminal (Unmarked) Terminal (Marked) Splice Factory Wiring Field Wiring To indicate common potential only. Not to represent wiring. To Indicate FIOP or Accessory THERMOSTAT MARKINGS BM — Blower Motor C — Common CM — Inducer Motor CS — Centrifugal Switch G — Fan IFO — Indoor Fan On L1 — Line 1 R — Thermostat Power RT — Power Supply SS — Speed Sensor W1 — Thermostat Heat Stage 1 W2 — Thermostat Heat Stage 2 X — Alarm Output Y1 — Thermostat Cooling Stage 1 Y2 — Thermostat Cooling Stage 2 NOTES: 1. Factory wiring is in accordance with the National Electrical Codes. Any field modifications or additions must be in compliance with all applicable codes. 2. Use 75° C min wire for field power supply, use copper wires for all units. 3. All circuit breakers “Must Trip Amps” are equal to or less than 156% RLA. 4. Compressor and fan motors are thermally protected — three phase motors protected against primary single phase conditions. 5. Red jumper wire must be added between R, W1, and W2 for space temperature sensor and all VAV units with heat and temporarily during Service Test mode when the heaters need to operate. 117 Table 115 — Main Control Board (MBB) Inputs and Outputs POINT NAME INPUTS GASFAN FSD G W2 W1 Y2 Y1 CSB_A1 CSB_A2 CSB_B1 CSB_B2 DP_A/SCTA DP_B/SCTB SP_A/SSTA SP_B/SSTB RAT SA_TEMP OAT SPT SPTO IAQ/IAQMINOV FLTS OUTPUTS CMPB2 CMPB1 CMPA2 CMPA1 CONDFANB CONDFANA HS2 HS1 HIR SF ALRM POINT DESCRIPTION YAC Indoor Fan relay (fan request from YAC) Fire Shutdown switch input Thermostat ‘G’ input Thermostat ‘W2’ input Thermostat ‘W1’ input Thermostat ‘Y2’ input Thermostat ‘Y1’ input Compressor A1 current sensor Compressor A2 current sensor Compressor B1 current sensor Compressor B2 current sensor Circuit A saturated condensing pressure/temp Circuit B saturated condensing pressure/temp Circuit A saturated suction pressure/temp Circuit B saturated suction pressure/temp Return air temperature Supply air temperature Outdoor air temperature Space temperature (T55/56) Space temperature offset (T56) IAQ analog input Filter Status Compressor B2 Compressor B1 Compressor A2 Compressor A1 Condenser fan B Condenser fan A Heat stage 2 Heat stage 1 Heat interlock relay Supply fan Alarm output relay I/O POINT NAME PLUG AND PIN REFERENCE DI1 DI2 DI3 DI4 DI5 DI6 DI7 DIG1 DIG2 DIG3 DIG4 J6, 3-4 J6, 5-6 J7, 1-2 J7, 3-4 J7, 5-6 J7, 7-8 J7, 9-10 J9, 10-12 J9, 7-9 J9, 4-6 J9, 1-3 AN1 J8, 21-23 AN2 J8, 24-26 AN3 J8, 15-17 SIGNAL PIN(S) PORT STATE 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac 0 = 5vdc, 1 = 0vdc 0 = 5vdc, 1 = 0vdc 0 = 5vdc, 1 = 0vdc 0 = 5vdc, 1 = 0vdc AN4 J8, 18-20 AN5 AN6 AN7 AN8 AN9 AN10 AN11 J8, 9-10 J8, 11-12 J8, 13-14 J8, 1-2 J8, 3-4 J8, 5-6 J8, 7-8 4 6 2 4 6 8 10 10=5v, 11=Vin, 12=GND 7=5v, 8=Vin, 9=GND 4=5v, 5=Vin, 6 =GND 1=5v, 2=Vin, 3=GND 21=5v, 22=Vin, 23=GND (thermistor 21-22) 24=5v, 25=Vin, 26=GND (thermistor 24-25) 15=5v, 16=Vin, 17=GND (thermistor 15-16) 18=5v, 19=Vin, 20=GND (thermistor 18-20) 9 11 13 1 3 5 7 RLY 1 RLY 2 RLY 3 RLY 4 RLY 5 RLY 6 RLY7 RLY 8 RLY 9 RLY 10 RLY 11 J10, 20-21 J10, 22-23 J10, 24-25 J10, 26-27 J10, 10-11 J10, 12-13 J10, 14-16 J10, 17-19 J10, 4-6 J10, 7-9 J10, 1-3 20 = RLY1A (=RLY2A), 21 = RLY1B 22 = RLY2A (=RLY1A), 23 = RLY2B 24 = RLY3A (=RLY4A), 25 = RLY3B 26 = RLY4A (=RLY3A), 27 = RLY4B 10 = RLY5A (=RLY6A), 11 = RLY5B 12 = RLY6A (=RLY5A), 13 = RLY6B 14 = 15 = RLY7A, 16 = RLY7B 17 = 18 = RLY8A, 19 = RLY8B 4 = 5 = RLY9A, 6 = RLY9B 7 = 8 = RLY10A, 9 = RLY10B 1 = 2 = RLY11A, 3 = RLY11B (0-5vdc, thermistor, ohms) (0-5vdc, thermistor, ohms) (0-5vdc, thermistor, ohms) (0-5vdc, thermistor, ohms) (thermistor, ohms) (thermistor, ohms) (thermistor, ohms) (thermistor, ohms) (thermistor, ohms) (thermistor, ohms) (thermistor, ohms) 1 = Closes RLY1A/RLY1B 1 = Closes RLY2A/RLY2B 1 = Closes RLY3A/RLY3B 1 = Closes RLY4A/RLY4B 1 = Closes RLY5A/RLY5B 1 = Closes RLY6A/RLY6B 1 = Closes RLY7A/RLY7B 1 = Closes RLY8A/RLY8B 1 = Closes RLY9A/RLY9B 1 = Closes RLY10A/RLY10B 1 = Closes RLY11A/RLY11B YAC — Gas Heat Unit RED LED - STATUS GREEN LEDLEN (LOCAL EQUIPMENT NETWORK) YELLOW LED CCN (CARRIER COMFORT NETWORK) INSTANCE JUMPER (SET TO 1) CEPL130346-01 HK 50AA029 CE BO 430346 J1 J4 STATUS J2 J10 LEN J3 J5 J6 A48-7811 J7 J8 Fig. 26 — Main Base Board (MBB) 118 J9 Table 116 — Economizer Control Board (ECB1) Inputs and Outputs POINT NAME INPUTS RMTIN ECONENBL, ECOORIDE RARH OARH OUTPUTS ECB1_AO1 ECONOCMD PE_A PE_B PE_C ECON_PWR I/O POINT NAME PLUG AND PIN REFERENCE SIGNAL PIN(S) PORT STATE Remote occupancy DI1 J4, 1-2 2 24VAC = 1, 0VAC = 0 Economizer enable DI2 J4, 3-4 4 24VAC = 1, 0VAC = 0 Return air relative humidity Outdoor air relative humidity AN1 AN2 J5, 1-3 J5, 4-6 1=24VDC, 2=0-20mA in, 3=GND 4=24VDC, 5=0-20mA in, 6=GND 0-20mA 0-20mA ECB1, analog output 1 Economizer actuator (digital control) Power Exhaust stage A Power Exhaust stage B Power Exhaust stage C Economizer Power AO1 J9, 1-2 1=0-20mA, 2=GND 0-20mA OUT PP/MP J7, 1-3 1=PP/MP Data, 2=24VAC, 3=GND Belimo PP/MP Protocol RLY1 RLY 2 RLY 3 RLY 6 J8, 1-3 J8, 4-6 J8, 7-9 J8, 16-18 1 = 2 = RLY1A, 3 = RLY1B 4 =5 = RLY2A, 6 = RLY2B 7 = 8 = RLY3A, 9 = RLY3B 16 = 17 = RLY6A, 18 = RLY6B 1 = Closes RLY1A/RLY1B 1 = Closes RLY2A/RLY2B 1 = Closes RLY3A/RLY3B 1 = Closes RLY6A/RLY6B POINT DESCRIPTION A48-7706 Fig. 27 — Economizer Control Board (ECB1) and VAV Control Board (ECB2) 119 Table 117 — VAV Control Board (ECB2) Inputs and Outputs POINT NAME INPUTS POINT DESCRIPTION I/O POINT NAME PLUG AND PIN REFERENCE SIGNAL PIN(S) PORT STATE DI1 DI2 AN1 AN2 J4, 1-2 J4, 3-4 J5, 1-3 J5, 4-6 2 4 1=24VDC, 2=0-20mA in, 3=GND 4=24VDC, 5=0-20mA in, 6=GND 24VAC = 1, 0VAC = 0 24VAC = 1, 0VAC = 0 0-20mA 0-20mA AO1 PP/MP RLY1 RLY 2 RLY 3 RLY 6 J9, 1-2 J7, 1-3 J8, 1-3 J8, 4-6 J8, 7-9 J8, 16-18 1=0-20mA, 2=GND 1=PP/MP Data, 2=24VAC, 3=GND 1 = 2 = RLY1A, 3 = RLY1B 4 =5 = RLY2A, 6 = RLY2B 7 = 8 = RLY3A, 9 = RLY3B 16 = 17 = RLY6A, 18 = RLY6B 0-20mA OUT Belimo PP/MP Protocol 1 = Closes RLY1A/RLY1B 1 = Closes RLY2A/RLY2B 1 = Closes RLY3A/RLY3B 1 = Closes RLY6A/RLY6B BP Building static pressure SP Supply Duct static pressure OUTPUTS SFAN_VFD Supply Fan Inverter speed Minimum load valve ADDRESS DIP SWITCHES ALL ON RED LEDSTATUS CEBD430427 GREEN LEDLEN (LOCAL EQUIPMENT NETWORK) HK50AA032 CEPL130427 J2 J1 PWR PWR J4 1 1 LEN LEN 4 J3 13 4 13 10 10 7 XDCR/THERM 7 RELAYS 4-POSITION DIP SWITCH A48-7707 1 J9 MLV J5 J6 J7 4 7 XDCR/THERM 1 3 1 J8 3 THERM 1 0-20mA OUT Fig. 28 — Staged Gas Heat Control Board (SCB) 120 Table 118 — Staged Gas Control Board (SCB) Inputs and Outputs POINT NAME INPUTS POINT DESCRIPTION I/O POINT NAME PLUG AND PIN REFERENCE SIGNAL PIN(S) PORT STATE AN1 AN2 AN3 AN4 AN5 AN6 AN7 AN8 AN9 AN10 J5, 1-3 J5, 4-6 J5, 7-9 J5, 10-12 J5, 13-15 J6, 1-3 J6, 4-6 J6, 7-9 J7, 1-2 J7, 3-4 1=5v, 2=Vin, 3=GND (thermistor 1-2) 4=5v, 5=Vin, 6=GND (thermistor 4-5) 7=5v, 8=Vin, 9=GND (thermistor 7-8) 10=5v, 11=Vin, 12=GND (thermistor 10-11) 13=5v, 14=Vin, 15=GND (thermistor 13-14) 1=5v, 2=Vin, 3=GND (thermistor 1-2) 4=5v, 5=Vin, 6=GND (thermistor 4-5) 7=5v, 8=Vin, 9=GND (thermistor 7-8) 1 3 (0-5VDC, thermistor, ohms) (0-5VDC, thermistor, ohms) (0-5VDC, thermistor, ohms) (0-5VDC, thermistor, ohms) (0-5VDC, thermistor, ohms) (0-5VDC, thermistor, ohms) (0-5VDC, thermistor, ohms) (0-5VDC, thermistor, ohms) (thermistor, ohms) (thermistor, ohms) AO1 AO2 RLY1 RLY 2 RLY 3 RLY 4 RLY 5 J8, 1-2 J8, 3-4 J9, 1-3 J9, 4-6 J9, 7-9 J9, 10-12 J9, 13-15 1=0-20mA, 2=GND 3=0-20mA, 4=GND 1 = 2 = RLY1A, 3 = RLY1B 4 = 5 = RLY2A, 6 = RLY2B 7 = 8 = RLY3A, 9 = RLY3B 10 = 11= RLY4A, 12 = RLY4B 13 = 14 = RLY5A, 15 = RLY5B 0-20mA OUT 0-20mA OUT 1 = Closes RLY1A/RLY1B 1 = Closes RLY2A/RLY2B 1 = Closes RLY3A/RLY3B 1 = Closes RLY4A/RLY4B 1 = Closes RLY5A/RLY5B LAT1SGAS Leaving air temperature 1 LAT2SGAS Leaving air temperature 2 LAT3SGAS Leaving air temperature 3 OUTPUTS HS3 HS4 HS5 HS6 Heat Stage 3 Heat Stage 4 Heat Stage 5 Heat Stage 6 J2 LEN J3 TEST 1 PWR J4 J1 STATUS CEPL130351-01 CEBD430351 J5 J7 J6 RED LED - STATUS TEST 2 GREEN LED LEN (LOCAL EQUIPMENT NETWORK) Fig. 29 — Controls Expansion Board (CEM) 121 ADDRESS DIP SWITCH (ALL ON) A48-7708 Table 119 — Controls Expansion Board (CEM) Inputs POINT NAME INPUTS SFS DMD_SW1 DMD_SW2/ DHD ISCIN PRES EVAC PURG IAQIN DMDLMTMA EDTRESMA OAQ SPRESET CEM_10K1/ CEM_4201 CEM_10K2/ CEM_4202 CEM_10K3/ CEM_4203 CEM_10K4/ CEM_4204 POINT DESCRIPTION I/O POINT NAME PLUG AND PIN REFERENCE SIGNAL PIN(S) PORT STATE DI 1 DI 2 J7, 1-2 J7, 3-4 2 4 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac DI 3 J7, 5-6 6 0 = 24vac, 1= 0vac DI 4 DI 5 DI 6 DI 7 AN7 AN8 AN9 AN10 AN10 J7, 7-8 J7, 9-10 J7, 11-12 J7, 13-14 J6, 1-3 J6, 4-6 J6, 7-9 J6, 10-12 J6, 10-12 8 10 12 14 2 (1 = loop power) 5 (4 = loop power) 8 (7 = loop power) 11 (10 = loop power) 11 (10 = loop power) 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac 0 = 24vac, 1= 0vac (0-20mA input) (0-20mA input) (0-20mA input) (0-20mA input) (0-20mA input) AN1 J5, 1-2 1 (thermistor, ohms) AN2 J5, 3-4 3 (thermistor, ohms) AN3 J5, 5-6 5 (thermistor, ohms) AN4 J5, 7-8 7 (thermistor, ohms) AN5 AN6 J5, 9-10 J5, 11-12 9 11 (thermistor, ohms) (thermistor, ohms) Supply Fan Status switch Demand Limit - SW1 Demand Limit - SW2/ Dehumidification Switch Input Pressurization Evacuation Purge Indoor Air Quality Switch 4-20mA Demand Limit 4-20mA Evaporator Discharge SP Reset Outside Air CO2 Sensor SP Reset milliamps CEM AN1 10k temp J5,1-2/ CEM AN1 4-20 ma J5,1-2 CEM AN2 10k temp J5,3-4/ CEM AN2 4-20 ma J5,3-4 CEM AN3 10k temp J5,5-6/ CEM AN3 4-20 ma J5,5-6 CEM AN4 10k temp J5,7-8/ CEM AN4 4-20 ma J5,7-8 pressures typically obtained from gages. The control includes a full alarm history, which can be accessed from the display. In addition, through the scrolling marquee the user can access a built-in test routine that can be used at start-up commission and to diagnose operational problems with the unit. The scrolling marquee is located in the main control box and is standard on all units. SUPPLY FAN — The size 020 to 050 units are equipped with two 15 x 11-in. forward-curved fans. The size 051 and 060 units have three 15 x 11-in. fans. They are on a common shaft and are driven by single belt drive 3-phase motor. The fan is controlled directly by the ComfortLink™ controls. VARIABLE FREQUENCY DRIVE (VFD) — On variable volume units, the supply fan speed is controlled by a 3-phase VFD. The VFD is located in the fan section behind a removable panel as shown in Fig. 24 and 25. The VFD speed is controlled directly by the ComfortLink controls through a 4 to 20 mA signal based on a supply duct pressure sensor. The inverter has a display, which can be used for service diagnostics, but setup of the supply duct pressure set point and control loop factors is done through the scrolling marquee display. The VFD is powered during normal operation to prevent condensation from forming on the boards during the off mode and is stopped by driving the speed to 0 (by sending a 2 mA signal to the VFD). The A Series units use ABB ACH550 VFDs. The interface wiring for the VFDs is shown in Fig. 31. Terminal designations are shown in Table 121. Table 120 — IGC Board Inputs and Outputs POINT NAME INPUTS RT W G LS RS SS CS FS OUTPUTS CM IFO R SPARK LED POINT DESCRIPTION 24 Volt Power Supply Heat Demand Fan Limit Switch Rollout Switch Hall Effect Sensor Centrifugal Switch (Not Used) Flame Sense Induced Draft Motor Indoor Fan 24 Volt Power Output (Not Used) Sparker Display LED CONNECTOR PIN NO. R1,C 2 3 7,8 5,6 1,2,3 9,10 FS CM IFO R — SCROLLING MARQUEE — This device is the keypad interface used to access the control information, read sensor values, and test the unit. The scrolling marquee display is a 4-key, 4-character, 16-segment LED display as well as an Alarm Status LED. See Fig. 30. The display is easy to operate using 4 buttons and a group of 11 LEDs that indicate the following menu structures: • Run Status • Service Test • Temperatures • Pressures • Set points • Inputs • Outputs • Configuration • Timeclock • Operating Modes • Alarms Through the scrolling marquee the user can access all the inputs and outputs to check on their values and status. Because the unit is equipped with suction pressure transducers and discharge saturation temperature sensors it can also display MODE Run Status Service Test Temperature Pressures Setpoints Inputs Alarm Status Outputs Configuration Time Clock Operating Modes Alarms ESCAPE ENTER A30-2239 Fig. 30 — Scrolling Marquee 122 + – A48-7709 Fig. 31 — VFD Wiring accurate control of the motors as well as feedback information and diagnostics information. The control has a self-calibration routine that allows the motor position to be configured at initial unit start-up. The motor is located on the economizer and can be reached through the filter access door. THERMISTORS AND PRESSURE TRANSDUCERS — The 48/50AJ,AK,AW,AY units are equipped with thermistors and pressure transducers. These units have two thermistors connected to the condenser coil and two pressure transducers that are connected to the low side of the system. The 48/50A2,A3,A4,A5 units are equipped with four pressure transducers. These units have two pressure transducers connected to the low side of the system and two pressure transducers connected to the high side of the system. By using either temperature sensors or transducers, the ComfortLink controller displays the high and low side pressures and saturation temperatures. A normal gage set is not required. SMOKE DETECTOR — The units can be equipped with an optional smoke detector located in the return air. The detector is wired to the ComfortLink controls and, if activated, will stop the unit by means of a special fire mode. The smoke detector can also be wired to an external alarm system through TB5 terminals 10 and 11. The sensor is located in the return air section behind the filter access door. FILTER STATUS SWITCH — The units can be equipped with an optional filter status switch. The switch measures the pressure drop across the filters and closes when an adjustable pressure set point is exceeded. The sensor is located in the return air section behind the filter access door. RETURN AIR CO2 SENSOR — The unit can also be equipped with a return air IAQ CO2 sensor that is used for the demand control ventilation. The sensor is located in the return air section and can be accessed from the filter access door. Table 121 — VFD Terminal Designations TERMINAL U1 V1 W1 U2 V2 W2 X1-11 (GND) X1-12 (COMMON) X1-10 (24 VDC) X1-13 (DI-1) X1-10 (24 VDC) X1-16 (DI-4) X1-2 (AI-1) X1-3 (AGND) FUNCTION Three-Phase Main Circuit Input Power Supply Three-Phase AC Output to Motor, 0 V to Maximum Input Voltage Level Factory-supplied jumper Run (factory-supplied jumper) Start Enable 1 (factory-supplied jumper). When opened the drive goes to emergency stop. Factory wired for 4 to 20 mA remote input POWER EXHAUST — The units can be equipped with an optional power exhaust system. The power exhaust fans are forward-curved fans with direct-drive motors. The motors are controlled directly by the ComfortLink™ controls through the ECB1 board. On the 48/50A020-050 units there are 4 fans. On the 48/50A051 and 060 units there are 6 fans. The fan sequences are controlled to provide 4 stages on the 48/50A020-050 units and 6 stages on the 48/50A051 and 060 units. There are two control methods. For CV applications the fans can be configured for 2 stages based on adjustable economizer damper positions. For VAV applications and CV units with the building pressure control option, the fans are sequenced to maintain a building pressure set point based on a building pressure transducer. ECONOMIZER MOTOR — The economizer outside air and return air dampers are gear-driven dampers without linkage. A digitally controlled economizer motor controls their position. The motor position is controlled by the ECB1 board by means of a digital two-way communication signal. This allows for 123 • outdoor air enthalpy curves • differential enthalpy • custom curves (a combination of an enthalpy/dewpoint curve and a dry bulb curve). The units are equipped as standard with an outside air and return air dry bulb sensor which supports the dry bulb changeover methods. If the other methods are to be used, then a fieldinstalled humidity sensor must be installed for outdoor air enthalpy and customer curve control and two humidity sensors must be installed for differential enthalpy. Installation holes are pre-drilled and wire harnesses are installed in every unit for connection of the humidity sensors. The ComfortLink controls convert the measured humidity into enthalpy, dewpoint, and the humidity changeover curves. MOTORMASTER® V CONTROL — For operation below 32 F when an economizer is not used, the units can be equipped with an accessory Motormaster V control, which controls the speed of the stage 1 condenser fans. The Motormaster V control is a 3-phase inverter that controls the speed of the fans based on a pressure transducer connected to the liquid line. On 48/ 50A020-035 units, one fan will be controlled. On 48/50A036060 units, two fans will be controlled. For units equipped with an economizer, there should not be a need for this control because the economizer can provide free cooling using outside air, which will be significantly lower in operating cost. The accessory Motormaster V speed control is a completely self-contained control and is not controlled by the unit’s ComfortLink controller. On 48/50A051 and 060 units with 6 fan motors, the Motormaster control configuration (M.M.) must be set to YES. See page 39. ACCESSORY NAVIGATOR™ DISPLAY — The accessory handheld Navigator display can be used with the 48/50A series units. See Fig. 34. The Navigator display operates the same way as the scrolling marquee device. The ECB1 and ECB2 boards contain a second LEN port (J3 connection) than can be used with the handheld Navigator display. CONTROL MODULE COMMUNICATIONS Red LED — Proper operation of the control boards can be visually checked by looking at the red status LEDs as shown on Fig. 26-29. When operating correctly, the red status LEDs should blink in unison at a rate of once every 2 seconds. If the red LEDs are not blinking in unison, verify that correct power is being supplied to all modules. Also, be sure that the main base board is supplied with the current software. If necessary, reload current software. If the problem still persists, replace the MBB. A board LED that is lit continuously or blinking at a rate of once per second or faster indicates that the board should be replaced. BOARD ADDRESSES — Each board in the system has an address. The MBB has a default address of 1 but it does have an instance jumper that should be set to 1 as shown in Fig. 26. For the other boards in the system there is a 4-dip switch header on each board that should be set as shown below. BOARD ECB1 ECB2 SCB CEM SW1 0 1 0 0 SW2 0 0 0 0 SW3 0 0 0 0 SW4 0 0 0 0 0 = On; 1 = Off FIELD CONNECTION TERMINAL STRIPS — Field connection terminal strips are located in the main control box. See Fig. 32 and Table 122. Accessory Control Components — In addition to the factory-installed options, the units can also be equipped with several field-installed accessories that expand the control features of the unit. The following hardware components can be used as accessories. ROOM THERMOSTATS (48/50AJ,AW,A2,A4 UNITS ONLY) — The ComfortLink™ controls support a conventional electro-mechanical or electronic thermostat that uses the Y1, Y2, W1, W2, and G signals. The control also supports an additional input for an occupied/unoccupied command that is available on some new thermostats. The ComfortLink controls can be configured to run with multiple stages of capacity which allows up to 6 stages of capacity. Although the unit can be configured for normal 2-stage control, it is recommended that the multi-stage control be used. The room thermostat is connected to TB4. SPACE SENSOR — The ComfortLink controls support the use of space temperature sensors. The T55 and T56 sensors and CCN communicating T58 room sensor can be used. The T55 and T56 sensors are connected to TB5 terminal 3, 4, and 5. The T58 sensor is connected to the CCN connections on TB3. When a T55, T56, or T58 sensor is used, the user must install the red jumpers from R to W1, and W2 on TB4 for the heat function to work correctly. SPACE CO2 SENSORS — The ComfortLink controls also support a CO2 IAQ sensor that can be located in the space for use in demand ventilation. The sensor must be a 4 to 20 mA sensor and should be connected to TB5 terminal 6 and 7. See Fig. 33 for sensor wiring. ECONOMIZER HUMIDITY CHANGEOVER SENSORS — The ComfortLink controls support 5 different changeover schemes for the economizer. These are: • outdoor air dry bulb • differential dry bulb + C 1 - GRD 3 5 7 9 11 13 15 TB3 LEN CCN TB5 CCN R Y1 Y2 W1 W2 G C X 1 2 7 8 TB4 3 4 5 6 2 4 6 8 10 12 14 16 1 3 5 7 9 11 13 15 TB6 2 A48-7081 4 6 8 10 12 Fig. 32 — Field Connection Terminal Strips (Main Control Box) 124 14 16 Table 122 — Field Connection Terminal Strips TERMINAL TERMINAL DESCRIPTION BOARD NO. TB-1 - POWER CONNECTION OR DISCONNECT (in Main Control Box) 11 L1 power supply TB1 12 L2 power supply 13 L3 power supply TB-2 - GROUND (in Main Control Box) TB2 1 Neutral Power TB-3 - CCN COMMUNICATIONS (HY84HA096) (in Main Control Box) 1 LEN + 2 LEN C 3 LEN – 4 24 VAC TB3 5 CCN + 6 CCN c 7 CCN – 8 Grd TB-4 - THEROMSTAT CONNECTIONS (HY84HA090) (in Main Control Box) 1 Thermostat R 2 Thermostat Y1 3 Thermostat Y2 4 Thermostat W1 TB4 5 Thermostat W2 6 Thermostat G 7 Thermostat C 8 Thermostat X TB-5 - FIELD CONNECTIONS (HY84HA101) (in Main Control Box) 1 VAV Heater Interlock Relay, Ground 2 VAV Heater Interlock Relay, 24 VAC 3 T56 Sensor 4 T56/T58 Ground 5 T58 Setpoint 6 Indoor Air IAQ Remote Sensor/Remote Pot/Remote 4-20 mA 7 Indoor Air IAQ Remote Sensor/Remote Pot/Remote 4-20 mA 8 Smoke Detector Remote Alarm TB5 9 Smoke Detector Remote Alarm 10 Fire Shutdown 11 Fire Shutdown 12 Fire Control Common 13 Fire Pressurization 14 Fire Evacuation 15 Fire Smoke Purge 16 Not Used TB-6 - FIELD CONNECTIONS (HY84HA101) (in Main Control Box) 1 Remote Occupied/Economizer Enable 24 VAC 2 Remote Economizer Contact 3 Remote Occupied Contact 4 Demand Limit Contacts Common 5 Demand Limit Switch 1 6 Demand Limit Switch 2/Dehumidify Switch Input 7 Demand Limit 4-20 mA 8 Demand Limit 4-20 mA TB6 9 Remote Supply Air Setpoint 4-20 mA 10 Remote Supply Air Setpoint 4-20 mA 11 Outdoor Air IAQ 4-20 mA 12 Outdoor Air IAQ 4-20 mA 13 IAQ Remote Switch 14 IAQ Remote Switch 15 Supply Fan Status Switch 16 Supply Fan Status Switch TB-7 - ELECTRIC HEAT POWER BLOCK (in Electric Heat section) 1 L1 Power Supply TB7 2 L2 Power Supply 3 L3 Power Supply 125 TYPE 208-230/460/575/380/-3-60, 400-3-50 208-230/460/575/380/-3-60, 400-3-50 208-230/460/575/380/-3-60, 400-3-50 5 VDC, logic 5 VDC, logic 5 VDC, logic 24 VAC 5 VDC, logic 5 VDC, logic 5 VDC, logic ground 24VAC 24VAC 24VAC 24VAC 24VAC 24VAC 24VAC 24VAC external 24 VDC relay external 24 VDC relay 5VDC 5VDC 5VDC 4-20 mA, ext. powered w/res or 0-5 VDC 4-20 mA, ext. powered w/res or 0-5 VDC external contacts external contacts 24 VAC external external contact external contact external contact external contact external contact — external 24 VAC contact external 24 VAC contact external 24 VAC contact external 24 VAC contact external 24 VAC contact external 24 VAC contact externally powered 4-20 mA externally powered 4-20 mA externally powered 4-20 mA externally powered 4-20 mA externally powered 4-20 mA externally powered 4-20 mA external contact external contact — — 208-230/460/575/380/-3-60, 400-3-50 208-230/460/575/380/-3-60, 400-3-50 208-230/460/575/380/-3-60, 400-3-50 UNIT CONTROL BOX TB4 1 2 3 4 5 6 7 6 7 TB5 1 2 1 2 3 4 5 3 1 2 J4 3 2 1 J3 J5 OVERRIDE J6 B4 A48-7306 Fig. 33 — CO2 and Space Temperature Sensor Wiring (33ZCT55CO2 and 33ZCT56CO2) Green LED — The boards also have a green LED, which is the indicator of the operation of the LEN communications, which is used for communications between the boards. On the MBB board the Local Equipment Network (LEN) LED should always be blinking whenever power is on. All other boards have a LEN LED that will blink whenever power is on and there is communication occurring. If LEN LED is not blinking, check LEN connections for potential communication errors (J3 and J4 connectors). A 3-wire sensor bus accomplishes communication between modules. These 3 wires run in parallel from module to module. Yellow LED — The MBB has one yellow LED. The Carrier Comfort Network® (CCN) LED will blink during times of network communication. The other boards do not have a CCN communications port. CARRIER COMFORT NETWORK INTERFACE — The 48/50A Series units can be connected to the CCN interface if desired. The communication bus wiring is a shielded, 3-conductor cable with drain wire and is field supplied and installed. See the Installation Instructions for wiring information. The system elements are connected to the communication bus in a daisy chain arrangement. The positive pin of each system element communication connector must be wired to the positive pins of the system elements on either side of it. This is also required for the negative and signal ground pins of each system element. Wiring connections for CCN should be made at TB3. See Fig. 35. Consult the CCN Contractor’s Manual for further information. NOTE: Conductors and drain wire must be 20-AWG (American Wire Gage) minimum stranded, tinned copper. Individual conductors must be insulated with PVC, PVC/ nylon, vinyl, Teflon, or polyethylene. An aluminum/polyester 100% foil shield and an outer jacket of PVC, PVC/nylon, chrome vinyl, or Teflon with a minimum operating temperature range of –20 C to 60 C is required. It is important when connecting to a CCN communication bus that a color-coding scheme be used for the entire network to simplify the installation. It is recommended that red be used for the signal positive, black for the signal negative and white for the signal ground. Use a similar scheme for cables containing different colored wires. At each system element, the shields of its communication bus cables must be tied together. If the communication bus is entirely within one building, the resulting continuous shield must be connected to a ground at one point only. If the communication bus cable exits from one building and enters another, the shields must be connected to grounds at the lightning suppressor in each building where the cable enters or exits the building (one point per building only). Co m NA T IM E EWT LW T SETP MO fort VIG Li n k ATO R 12. 54. 58 44. 6 F 4 4 . 01 F F DE Run Statu s Servi ce Te st Temp eratur es Pres sures Setpo ints Inputs Al ar m St atu s Outpu ts Confi gurat ion Time Cloc k Opera ting Mode Alarm s s ENT ESC ER Fig. 34 — Accessory Navigator Display 126 5. Restore power to unit. To connect the unit to the network: 1. Turn off power to the control box. 2. Cut the CCN wire and strip the ends of the red (+), white (ground), and black (–) conductors. (Substitute appropriate colors for different colored cables.) 3. Connect the red wire to (+) terminal on TB3 of the plug, the white wire to COM terminal, and the black wire to the (–) terminal. 4. The RJ14 CCN connector on TB3 can also be used, but is only intended for temporary connection (for example, a laptop computer running Service Tool). IMPORTANT: A shorted CCN bus cable will prevent some routines from running and may prevent the unit from starting. If abnormal conditions occur, unplug the connector. If conditions return to normal, check the CCN connector and cable. Run new cable if necessary. A short in one section of the bus can cause problems with all system elements on the bus. CCN BUS ROOFTOP UNIT ROOFTOP UNIT CL CL COMPUTER WITH COMPUTER WITH ComfortVIEW™ ComfortView™ SOFTWARE SOFTWARE CCN WEB OR NETWORK OPTIONS ROOFTOP UNIT ROOFTOP UNIT CL CL HEATING/COOLING UNITS REMOTE CCN SITE TELINK BRIDGE (RECOMMENDED) TO ADDITIONAL TERMINALS CL CID ROOFTOP UNIT CID COMFORT ID AIR TERMINAL CID COMFORT ID AIR TERMINAL COMFORT ID FAN POWERED MIXING BOX NON CARRIER HVAC EQUIPMENT COMFORT CONTROLLER CCN CID CL HVAC — — — — AIR DISTRIBUTION-DIGITAL AIR VOLUME CONTROL (DAV) LEGEND Carrier Comfort Network® ComfortID™ Controls ComfortLink™ Controls Heating, Ventilation, and Air Conditioning Fig. 35 — CCN System Architecture 127 A48-7307 FLUE GAS PASSAGEWAYS — The flue collector box and heat exchanger cells may be inspected by removing gas section access panel, flue box cover, collector box, and main burner assembly (Fig. 38 and 39). Refer to Main Burners section on page 139 for burner removal sequence. If cleaning is required, clean all parts with a wire brush. Reassemble using new hightemperature insulation for sealing. SERVICE WARNING Before performing service or maintenance operations on unit, turn off main power switch to unit. Electrical shock could cause personal injury. Service Access — All unit components can be reached through clearly labelled hinged access doors. These doors are not equipped with tiebacks, so if heavy duty servicing is needed, either remove them or prop them open to prevent accidental closure. Each door is held closed with 3 latches. The latches are secured to the unit with a single 1/4-in. - 20 x 1/2-in. long bolt. See Fig. 36. To open, loosen the latch bolt using a 7/16-in. wrench. Pivot the latch so it is not in contact with the door. Open the door. To shut, reverse the above procedure. NOTE: Disassembly of the top cover may be required under special service circumstances. It is very important that the orientation and position of the top cover be marked on the unit prior to disassembly. This will allow proper replacement of the top cover onto the unit and prevent rainwater from leaking into the unit. A48-3821 Fig. 36 — Door Latch IMPORTANT: After servicing is completed, make sure door is closed and relatched properly, and that the latches are tight. Failure to do so can result in water leakage into the evaporator section of the unit. Cleaning — Inspect unit interior at beginning of each heating and cooling season and as operating conditions require. Remove unit side panels and/or open doors for access to unit interior. MAIN BURNERS — At the beginning of each heating season, inspect for deterioration or blockage due to corrosion or other causes. Observe the main burner flames and adjust if necessary. Check spark gap. See Fig. 37. Refer to Main Burners section on page 139. A48-4022 Fig. 37 — Spark Gap Adjustment NOTES: 1. Torque set screws on blower wheel to 70 in. lb ± 2 in. lb. 2. Torque set screw on propeller fan to 15 in. lb ± 2 in. lb. 3. Dimensions are in inches. A48-3822 Fig. 38 — Typical Gas Heating Section 128 of the coil. Failure to clean the coils may result in reduced durability in the environment. Avoid the use of: • coil brighteners • acid cleaning prior to painting • high pressure washers • poor quality water for cleaning Totaline environmentally sound coil cleaner is non-flammable, hypoallergenic, nonbacterial, and a USDA accepted biodegradable agent that will not harm the coil or surrounding components such as electrical wiring, painted metal surfaces, or insulation. Use of non-recommended coil cleaners is strongly discouraged since coil and unit durability could be affected. Totaline Environmentally Sound Coil Cleaner Application Equipment • 21/2 gallon garden sprayer • water rinse with low velocity spray nozzle A48-3727 Fig. 39 — Gas Heat Section Details CAUTION COMBUSTION-AIR BLOWER — Clean periodically to assure proper airflow and heating efficiency. Inspect blower wheel every fall and periodically during heating season. For the first heating season, inspect blower wheel bi-monthly to determine proper cleaning frequency. To inspect blower wheel, remove heat exchanger access panel. Shine a flashlight into opening to inspect wheel. If cleaning is required, remove motor and wheel assembly by removing screws holding motor mounting plate to top of combustion fan housing (Fig. 38 and 39). The motor, scroll, and wheel assembly can be removed from the unit. Remove scroll from plate. Remove the blower wheel from the motor shaft and clean with a detergent or solvent. Replace motor and wheel assembly. ROUND TUBE PLATE FIN COIL MAINTENANCE AND CLEANING RECOMMENDATIONS — Routine cleaning of coil surfaces is essential to maintain proper operation of the unit. Elimination of contamination and removal of harmful residues will greatly increase the life of the coil and extend the life of the unit. The following maintenance and cleaning procedures are recommended as part of the routine maintenance activities to extend the life of the coil. Remove Surface Loaded Fibers — Surface loaded fibers or dirt should be removed with a vacuum cleaner. If a vacuum cleaner is not available, a soft non-metallic bristle brush may be used. In either case, the tool should be applied in the direction of the fins. Coil surfaces can be easily damaged (fin edges can be easily bent over and damage to the coating of a protected coil) if the tool is applied across the fins. NOTE: Use of a water stream, such as a garden hose, against a surface loaded coil will drive the fibers and dirt into the coil. This will make cleaning efforts more difficult. Surface loaded fibers must be completely removed prior to using low velocity clean water rinse. Periodic Clean Water Rinse — A periodic clean water rinse is very beneficial for coils that are applied in coastal or industrial environments. However, it is very important that the water rinse is made with very low velocity water stream to avoid damaging the fin edges. Monthly cleaning as described below is recommended. Routine Cleaning of Coil Surfaces — Monthly cleaning with Totaline® environmentally sound coil cleaner is essential to extend the life of coils. This cleaner is available from Carrier Replacement parts division as part number P902-0301 for a one gallon container, and part number P902-0305 for a 5 gallon container. It is recommended that all coils, including copper tube aluminum fin, pre-coated fin, copper fin, or E-coated coils be cleaned with the Totaline environmentally sound coil cleaner as described below. Coil cleaning should be part of the unit’s regularly scheduled maintenance procedures to ensure long life Harsh chemicals, household bleach or acid or basic cleaners should not be used to clean outdoor or indoor coils of any kind. These cleaners can be very difficult to rinse out of the coil and can accelerate corrosion at the fin/tube interface where dissimilar materials are in contact. If there is dirt below the surface of the coil, use the Totaline environmentally sound coil cleaner as described above. CAUTION High velocity water from a pressure washer, garden hose, or compressed air should never be used to clean a coil. The force of the water or air jet will bend the fin edges and increase airside pressure drop. Reduced unit performance or nuisance unit shutdown may occur. Totaline Environmentally Sound Coil Cleaner Application Instructions 1. Remove any foreign objects or debris attached to the core face or trapped within the mounting frame and brackets. 2. Put on personal protective equipment including safety glasses and/or face shield, waterproof clothing and gloves. It is recommended to use full coverage clothing. 3. Remove all surface loaded fibers and dirt with a vacuum cleaner as described above. 4. Thoroughly wet finned surfaces with clean water and a low velocity garden hose, being careful not to bend fins. 5. Mix Totaline environmentally sound coil cleaner in a 21/2 gallon garden sprayer according to the instructions included with the cleaner. The optimum solution temperature is 100 F. NOTE: Do NOT USE water in excess of 130 F, as the enzymatic activity will be destroyed. 6. Thoroughly apply Totaline environmentally sound coil cleaner solution to all coil surfaces including finned area, tube sheets and coil headers. 7. Hold garden sprayer nozzle close to finned areas and apply cleaner with a vertical, up-and-down motion. Avoid spraying in horizontal pattern to minimize potential for fin damage. 8. Ensure cleaner thoroughly penetrates deep into finned areas. 9. Interior and exterior finned areas must be thoroughly cleaned. 10. Finned surfaces should remain wet with cleaning solution for 10 minutes. 129 11. Ensure surfaces are not allowed to dry before rinsing. Reapplying cleaner as needed to ensure 10-minute saturation is achieved. 12. Thoroughly rinse all surfaces with low velocity clean water using downward rinsing motion of water spray nozzle. Protect fins from damage from the spray nozzle. MICROCHANNEL HEAT EXCHANGER (MCHX) CONDENSER COIL MAINTENANCE AND CLEANING RECOMMENDATIONS Evaporator Fan Performance Adjustment (Fig. 40) — Fan motor pulleys are designed for speed shown in Physical Data table in unit Installation Instructions (factory speed setting). IMPORTANT: Check to ensure that the unit drive matches the duct static pressure using Tables 3-38. To change fan speeds, change pulleys. To align fan and motor pulleys: 1. Shut off unit power supply. 2. Loosen fan shaft pulley bushing. 3. Slide fan pulley along fan shaft. 4. Make angular alignment by loosening motor from mounting plate. 5. Retighten pulley. 6. Return power to the unit. CAUTION Do not apply any chemical cleaners to MCHX condenser coils. These cleaners can accelerate corrosion and damage the coil. Routine cleaning of coil surfaces is essential to maintain proper operation of the unit. Elimination of contamination and removal of harmful residues will greatly increase the life of the coil and extend the life of the unit. The following steps should be taken to clean MCHX condenser coils: 1. Remove any foreign objects or debris attached to the core face or trapped within the mounting frame and brackets. 2. Put on personal protective equipment including safety glasses and/or face shield, waterproof clothing and gloves. It is recommended to use full coverage clothing. 3. Start high pressure water sprayer and purge any soap or industrial cleaners from sprayer before cleaning condenser coils. Only clean potable water is authorized for cleaning condenser coils. 4. Clean condenser face by spraying the core steady and uniformly from top to bottom while directing the spray straight toward the core. Do not exceed 900 psig or 30 degree angle. The nozzle must be at least 12 in. from the core face. Reduce pressure and use caution to prevent damage to air centers. CAUTION Excessive water pressure will fracture the braze between air centers and refrigerant tubes. A48-4036 CONDENSATE DRAIN — Check and clean each year at start of cooling season. In winter, keep drains and traps dry. FILTERS — Clean or replace at start of each heating and cooling season, or more often if operating conditions require. Refer to Installation Instructions for type and size. NOTE: The unit requires industrial grade throwaway filters capable of withstanding face velocities up to 625 fpm. OUTDOOR-AIR INLET SCREENS — Clean screens with steam or hot water and a mild detergent. Do not use disposable filters in place of screens. Fig. 40 — Evaporator-Fan Alignment and Adjustment Evaporator Fan Coupling Assembly — If the coupling has been removed for other blower assembly component repair or replacement, it is critical that the coupling be reassembled and aligned correctly to prevent premature failures. REASSEMBLING THE COUPLING INTO THE UNIT (Fig. 41) 1. Prior to reassembling the coupling, loosen the 4 bearing mounting bolts, which secure the 2 bearings on either side of the coupling. Remove the drive belts. 2. Reassemble the coupling with the bearings loose. This allows the coupling to find its own self-alignment position. 3. Check the hub-to-shaft fit for close fitting clearances. Replace hubs if high clearances are determined. 4. Check the key for close-fitted clearances on the sides and 0.015 in. clearance over the top of the key. Replace key if necessary. 5. Be sure that hub flanges, flex members, spacer, and hardware are clean and free of oil. 6. Place the flanges onto the shafts with the hub facing outward. Do not tighten the set screws at this time. Lubrication FAN SHAFT BEARINGS — Lubricate bearings at least every 6 months with suitable bearing grease. Do not over grease. Typical lubricants are given below: MANUFACTURER LUBRICANT Texaco Regal AFB-2* Mobil Mobilplex EP No. 1 Sunoco Prestige 42 Texaco Multifak 2 *Preferred lubricant because it contains rust and oxidation inhibitors. CONDENSER AND EVAPORATOR-FAN MOTOR BEARINGS — The condenser and evaporator-fan motors have permanently sealed bearings, so no field lubrication is necessary. 130 CENTER DRIVE SHAFT FLEX MEMBER SHAFT FLANGE SHAFT BEARINGS A50-5146 Fig. 41 — Evaporator Fan Coupling 6. Adjust bolts and nut on mounting plate to secure motor in 7. Outside of the unit, assemble the flex members to the cenfixed position. Recheck belt tension after 24 hours of ter drive shaft with 4 bolts and nuts. The flex members operation. Adjust as necessary. Refer to Installation Inhave collars that need to be inserted into the smaller hole structions for proper tension values. of the drive shaft flange. 7. Restore power to unit. 8. Assemble the flex member/drive shaft assembly to one of the shaft flanges, using 2 bolts and nuts. Slide the other Evaporator-Fan Motor Replacement shaft flange towards the assembly and assemble using 2 bolts and nuts. If the shafts are not misaligned, the collar 1. Turn off unit power supply. in the flex member should line up with the shaft flange 2. Remove upper outside panel and open hinged door to holes. gain access to motor. 9. Torque nuts properly to 95 to 100 ft-lb. Do not turn a cou3. Fully retract motor plate adjusting bolts. pling bolt. Always turn the nut. Always use thread lubri4. Loosen the 2 rear (nearest the evaporator coil) motor plate cant or anti-seize compound to prevent thread galling. nuts. 10. The ends of the shafts should be flush with the inside of 5. Remove the 2 front motor plate nuts and carriage bolts. the shaft flange. Torque the set screws to 25 ft-lb. 6. Slide motor plate to the rear (toward the coil) and remove 11. After assembly is complete, slowly rotate the shafts by fan belt(s). hand for 30 to 60 seconds. 7. Slide motor plate to the front and hand tighten one of the 12. Tighten the bearing mounting bolts, using care not to rear motor plate nuts (tight enough to prevent the motor place any loads on the shaft which would cause flexure to plate from sliding back but loose enough to allow the the shafts. plate to pivot upward). 13. Reinstall drive belts. (Refer to Belt Tension Adjustment 8. Pivot the front of the motor plate upward enough to allow section below.) access to the motor mounting hex bolts and secure in 14. Visually inspect the assembly. If the shafts are overly misplace by inserting a prop. aligned, the drive shaft flange will not be parallel with the 9. Remove the nuts from the motor mounting hex bolts and shaft flanges. remove motor. 15. Recheck nut torque after 1 to 2 hours of operation. Bolts 10. Replace the locktooth washer under the motor base with a tend to relax after being initially torqued. new washer. Be sure that the washer contacts the motor base surface. Evaporator Fan Service and Replacement 11. Reverse above steps to install new motor. 1. Turn off unit power supply. 2. Remove supply-air section panels. 3. Remove belt and blower pulley. 4. Loosen setscrews in blower wheels. 5. Remove locking collars from bearings. 6. Remove shaft. 7. Remove venturi on opposite side of bearing. 8. Lift out wheel. 9. Reverse above procedure to reinstall fan. 10. Check and adjust belt tension as necessary. 11. Restore power to unit. Belt Tension Adjustment — To adjust belt tension: 1. 2. 3. 4. Turn off unit power supply. Loosen motor mounting nuts and bolts. See Fig. 42. Loosen fan motor nuts. Turn motor jacking bolts to move motor mounting plate left or right for proper belt tension. A slight bow should be present in the belt on the slack side of the drive while running under full load. 5. Tighten nuts. A48-3729 Fig. 42 — Belt Tension Adjustment 131 on the chart, add or remove charge in 1/4 lb increments until complete. Ensure that all fans are on and all compressors are running when using charging charts. To Use the Cooling Charging Chart — Use the outdoor air temperature, saturated suction temperature and saturated condensing temperature (available on the ComfortLink™ display), and find the intersection point on the cooling charging chart. If intersection point is above the line, carefully recover some of the refrigerant. If intersection point is below the line, carefully add refrigerant. NOTE: Indoor-air cfm must be within normal operating range of unit. Condenser-Fan Adjustment NOTE: Condenser fans on size 060 MCHX units are not adjustable. 1. Turn off unit power supply. 2. Remove fan guard. 3. Loosen fan hub setscrews. 4. Adjust fan height on shaft using a straightedge placed across venturi and measure per Fig. 43. 5. Fill hub recess with permagum if rubber hubcap is missing. 6. Tighten setscrews and replace panel(s). 7. Turn on unit power. Thermostatic Expansion Valve (TXV) — Each circuit has a TXV. The TXV is adjustable and is factory set to maintain 8 to 12° F superheat leaving the evaporator coil. The TXV controls flow of liquid refrigerant to the evaporator coils. Adjusting the TXV is not recommended. Four-Inch Filter Replacement — The 4-Inch Filter Change Mode variable is used to service the unit when 4-in. filters are used. When the filters need to be changed, set Service TestF.4.CH = YES. The unit will be placed in Service Test mode and the economizer will move to the 40% open position to facilitate removal of the 4-in. filters. After the filters have been changed, set Service TestF.4.CH = NO to return the unit to normal operation. Gas Valve Adjustment NATURAL GAS — The 2-stage gas valve opens and closes in response to the thermostat or limit control. When power is supplied to valve terminals 3 and 4, the pilot valve opens to the preset position. When power is supplied to terminals 1 and 2, the main valve opens to its preset position. The regular factory setting is stamped on the valve body (3.5 in. wg). To adjust regulator: 1. Set thermostat at setting for no call for heat. 2. Switch main gas valve to OFF position. 3. Remove 1/8-in. pipe plug from manifold. Install a water manometer pressure-measuring device. 4. Switch main gas valve to ON position. 5. Set thermostat at setting to call for heat (high fire). 6. Remove screw cap covering regulator adjustment screw (See Fig. 51). 7. Turn adjustment screw clockwise to increase pressure or counterclockwise to decrease pressure. 8. Once desired pressure is established, set unit to no call for heat (3.3-in. wg high fire). 9. Switch main gas valve to OFF position. 10. Remove pressure-measuring device and replace 1/8-in. pipe plug and screw cap. 11. Turn main gas valve to ON position and check heating operation. Power Failure — The economizer damper motor is a spring return design. In event of power failure, dampers will return to fully closed position until power is restored. Refrigerant Charge — Amount of refrigerant charge is listed on unit nameplate. Refer to Carrier GTAC II; Module 5; Charging, Recovery, Recycling, and Reclamation section for charging methods and procedures. Unit panels must be in place when unit is operating during charging procedure. NOTE: Do not use recycled refrigerant as it may contain contaminants. NO CHARGE — Use standard evacuating techniques. After evacuating system, weigh in the specified amount of refrigerant from the unit nameplate. LOW CHARGE COOLING All Units with Round Tube-Plate Fin Condenser Coils — Connect the gage set and a temperature-measuring device to the liquid line. Ensure that all condenser fans are operating. It may be necessary to block part of the coil on cold days to ensure that condensing pressures are high enough to turn on the fans. Adjust the refrigerant charge in each circuit to obtain state point liquid subcooling for specific models as listed in Table 123. NOTE: Indoor-air cfm must be within normal operating range of unit. Table 123 – Round Tube, Plate Fin Unit Charge UNIT 48/50 AJ,AK,AW,AY A2,A3,A4,A5 REFRIGERANT TYPE R-22 R-410A SIZE 020, 025, 027, 030, 035, 040, 050, 060 036 041, 051 020, 027, 040, 050, 060 030, 035 025 LIQUID SUBCOOLING A 20 F ± 2 F 18 F ± 2 F 15 F ± 2 F 15 F ± 2 F 20 F ± 2 F 12 F ± 2 F 48/50A2,A3,A4,A5 Units with MCHX Condenser — Due to the compact, all aluminum design, microchannel heat exchangers will reduce refrigerant charge and overall operating weight. As a result, charging procedures for MCHX units require more accurate measurement techniques. Charge should be added in small increments. Using cooling charging charts provided (Fig. 44-50), add or remove refrigerant until conditions of the chart are met. As conditions get close to the point UNIT SIZE DIMENSION “A” (in.) 020-035, 050 1.30 ± 0.12 036-041, 051, 060 0.87 ± 0.12 Fig. 43 — Condenser-Fan Adjustment (All Units Except Size 060 MCHX) 132 20 Ton MCHX CIRCUIT A Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 Saturated Discharge Temperature (deg F) 145 SST= 55 F SST= 45 F 140 SST= 35 F 135 130 125 Reduce Charge if Above Curve 120 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temperature (deg F) 20 Ton MCHX CIRCUIT B Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 SST= 55 F SST= 45 F SST= 35 F Saturated Discharge Temperature (deg F) 145 140 135 130 125 Reduce Charge if Above Curve 120 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temperature (deg F) LEGEND a48-8401 MCHX— Microchannel Heat Exchanger SST — Saturated Suction Temperature Fig. 44 — Charging Chart — 48/50A2,A3,A4,A5020 with R-410A Refrigerant 133 25 and 27 Ton MCHX CIRCUIT A Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 S S T= 5 5 F 145 Saturated Condensing Temperature (deg F) S S T= 4 5 F 140 S S T= 3 5 F 135 Reduce Charge if Above Curve 130 125 120 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temperature (deg F) 25 and 27 Ton MCHX CIRCUIT B Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 Saturated Condensing Temperature (deg F) 145 S S T= 5 5 F 140 S S T= 4 5 F 135 S S T= 3 5 F 130 125 Reduce Charge if Above Curve 120 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temperature (deg F) a48-8402 LEGEND MCHX— Microchannel Heat Exchanger SST — Saturated Suction Temperature Fig. 45 — Charging Chart — 48/50A2,A3,A4,A5025 and 027 with R-410A Refrigerant 134 30 Ton MCHX CIRCUIT A Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 Saturated Condensing Temperature (deg F) 145 S S T= 5 5 F S S T= 4 5 F 140 S S T= 3 5 F 135 130 125 Reduce Charge if Above Curve 120 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temperature (deg F) 30 Ton MCHX CIRCUIT B Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 S S T= 5 5 F Saturated Condensing Temperature (deg F) 145 S S T= 4 5 F S S T= 3 5 F 140 135 130 125 Reduce Charge if Above Curve 120 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temperature (deg F) LEGEND MCHX— Microchannel Heat Exchanger SST — Saturated Suction Temperature Fig. 46 — Charging Chart — 48/50A2,A3,A4,A5030 with R-410A Refrigerant 135 35 Ton MCHX CIRCUIT A Charging Chart Saturated Condensing Temperature (deg F) All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 SST= 55 F 145 SST= 45 F SST= 35 F 140 135 130 Reduce Charge if Above Curve 125 120 115 Add Charge if Below Curve 110 105 100 95 90 85 55 60 65 70 75 80 85 90 95 100 105 110 115 120 Outdoor Air Temperature (deg F) 35 Ton MCHX CIRCUIT B Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating SST= 55 F 155 SST= 45 F SST= 35 F Saturated Condensing Temperature (deg F) 150 145 140 135 Reduce Charge if Above Curve 130 125 120 115 Add Charge if Below Curve 110 105 100 95 90 85 55 60 65 70 75 80 85 90 95 100 105 110 115 Outdoor Air Temperature (deg F) LEGEND MCHX— Microchannel Heat Exchanger SST — Saturated Suction Temperature Fig. 47 — Charging Chart — 48/50A2,A3,A4,A5035 with R-410A Refrigerant 136 120 40 Ton MCHX Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 Saturated Condensing Temperature (deg F) S S T= 5 5 F 145 S S T= 4 5 F 140 S S T= 3 5 F 135 130 125 120 Reduce Charge if Above Curve 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temperature (deg F) LEGEND MCHX— Microchannel Heat Exchanger SST — Saturated Suction Temperature Fig. 48 — Charging Chart — 48/50A2,A3,A4,A5040 with R-410A Refrigerant 50 Ton MCHX Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 S S T= 5 5 F S S T= 4 5 F 145 Saturated Condensing Temperature (deg F) S S T= 3 5 F 140 135 130 125 120 Reduce Charge if Above Curve 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temperature (deg F) LEGEND MCHX— Microchannel Heat Exchanger SST — Saturated Suction Temperature Fig. 49 — Charging Chart — 48/50A2,A3,A4,A5050 with R-410A Refrigerant 137 60 Ton MCHX CIRCUIT A Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 Saturated Condensing Temperature (deg F) 145 S S T= 5 5 F S S T= 4 5 F 140 S S T= 3 5 F 135 130 125 Reduce Charge if Above Curve 120 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temperature (deg F) 60 Ton MCHX CIRCUIT B Charging Chart All Compressors on a Circuit Must be Operating All Outdoor Fans Must be Operating 150 S S T= 5 5 F Saturated Condensing Temperature (deg F) 145 S S T= 4 5 F S S T= 3 5 F 140 135 130 125 Reduce Charge if Above Curve 120 115 110 105 Add Charge if Below Curve 100 95 90 85 80 75 70 55 60 65 70 75 80 85 90 95 100 105 110 115 120 Outdoor Air Temperature (deg F) LEGEND MCHX— Microchannel Heat Exchanger SST — Saturated Suction Temperature Fig. 50 — Charging Chart — 48/50A2,A3,A4,A5060 with R-410A Refrigerant 138 125 Main Burners — For all applications, main burners are factory set and should require no adjustment. MAIN BURNER REMOVAL (Fig. 52) 1. Shut off (field-supplied) manual main gas valve. 2. Shut off power supply to unit. 3. Remove heating access panel. 4. Disconnect gas piping from gas valve inlet. 5. Remove wires from gas valve. 6. Remove wires from rollout switch. 7. Remove sensor wire and ignitor cable from IGC board. 8. Remove 2 screws securing manifold bracket to basepan. 9. Remove 4 screws that hold the burner support plate flange to the vestibule plate. 10. Lift burner assembly out of unit. 11. Reverse procedure to re-install burners. OUTLET PRESSURE TAP (ON SIDE) 1/8-IN. 27 NPT HIGH-FIRE REGULATOR ADJUSTMENT SCREW LOW-FIRE REGULATOR ADJUSTMENT SCREW INLET PRESSURE TAP (ON SIDE) 1/8-IN. 27 NPT ON/OFF SWITCH A48-8364 Fig. 51 — Gas Valve (Part Number EF33CW271) Filter Drier — Replace whenever refrigerant system is ex- posed to atmosphere. Replacement Parts — A complete list of replacement parts may be obtained from any Carrier distributor upon request. A48-3733 Fig. 52 — Main Burner Removal 139 APPENDIX A — LOCAL DISPLAY TABLES MODE — RUN STATUS ITEM VIEW HVAC OCC MAT EDT LAT EC.C.P ECN.P CL.C.P C.CAP HT.C.P HT.ST H.MAX ECON ECN.P ECN.C ACTV DISA DISAUNAV DISAR.EC.D DISADBC DISADEW DISADDBC DISAOAEC DISADEC DISAEDT DISAOAT DISAFORC DISASFON DISACLOF DISAOAQL DISAHELD DISADH.DS O.AIR O.AIROAT O.AIROA.RH O.AIROA.E O.AIROA.D.T COOL C.CAP CUR.S REQ.S MAX.S DEM.L SUMZ SUMZSMZ SUMZADD.R SUMZSUB.R SUMZR.PCT SUMZY.MIN SUMZY.PLU SUMZZ.MIN SUMZZ.PLU SUMZH.TMP SUMZL.TMP SUMZPULL SUMZSLOW TRIP UN.C.S UN.C.E OC.C.S OC.C.E TEMP OC.H.E OC.H.S UN.H.E UN.H.S HVAC LINK MODE L.Z.T L.C.SP L.H.SP HRS HR.A1 HR.A2 HR.B1 HR.B2 STRT ST.A1 ST.A2 ST.B1 ST.B2 EXPANSION AUTO VIEW OF RUN STATUS ascii string spelling out the hvac modes Occupied ? Mixed Air Temperature Evaporator Discharge Tmp Leaving Air Temperature Economizer Control Point Economizer Act.Curr.Pos. Cooling Control Point Current Running Capacity Heating Control Point Requested Heat Stage Maximum Heat Stages ECONOMIZER RUN STATUS Economizer Act.Curr.Pos. Economizer Act.Cmd.Pos. Economizer Active ? ECON DISABLING CONDITIONS Econ Act. Unavailable? Remote Econ. Disabled ? DBC - OAT Lockout? DEW - OA Dewpt.Lockout? DDBD- OAT > RAT Lockout? OAEC- OA Enth Lockout? DEC - Diff.Enth.Lockout? EDT Sensor Bad? OAT Sensor Bad ? Economizer Forced ? Supply Fan Not On 30s ? Cool Mode Not In Effect? OAQ Lockout in Effect ? Econ Recovery Hold Off? Dehumid. Disabled Econ? OUTSIDE AIR INFORMATION Outside Air Temperature Outside Air Rel. Humidity Outside Air Enthalpy OutsideAir Dewpoint Temp COOLING INFORMATION Current Running Capacity Current Cool Stage Requested Cool Stage Maximum Cool Stages Active Demand Limit COOL CAP. STAGE CONTROL Capacity Load Factor Next Stage EDT Decrease Next Stage EDT Increase Rise Per Percent Capacity Cap Deadband Subtracting Cap Deadband Adding Cap Threshold Subtracting Cap Threshold Adding High Temp Cap Override Low Temp Cap Override Pull Down Cap Override Slow Change Cap Override MODE TRIP HELPER Unoccup. Cool Mode Start Unoccup. Cool Mode End Occupied Cool Mode Start Occupied Cool Mode End Ctl.Temp RAT,SPT or Zone Occupied Heat Mode End Occupied Heat Mode Start Unoccup. Heat Mode End Unoccup. Heat Mode Start ascii string spelling out the hvac modes CCN - LINKAGE Linkage Active - CCN Linkage Zone Control Tmp Linkage Curr. Cool Setpt Linkage Curr. Heat Setpt COMPRESSOR RUN HOURS Compressor A1 Run Hours Compressor A2 Run Hours Compressor B1 Run Hours Compressor B2 Run Hours COMPRESSOR STARTS Compressor A1 Starts Compressor A2 Starts Compressor B1 Starts Compressor B2 Starts RANGE UNITS YES/NO 0-100 dF dF dF dF % dF dF 0-100 0-100 YES/NO % % YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO dF % forcible OAT OARH OAE OADEWTMP CAPTOTAL COOL_STG CL_STAGE CLMAXSTG DEM_LIM forcible forcible 90,91 90,91 90,91 90,91 90,91 50,63,70,90,91 90,91 41,42,63,90,91 90,91 53,90,91 54-56,90,91 54,90,91 50,64,91 64,91 42,50,64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 64,91 SMZ ADDRISE SUBRISE RISE_PCT Y_MINUS Y_PLUS Z_MINUS Z_PLUS HI_TEMP LOW_TEMP PULLDOWN SLO_CHNG UCCLSTRT UCCL_END OCCLSTRT OCCL_END CTRLTEMP OCHT_END OCHTSTRT UCHT_END UCHTSTRT string 46,53,92 46,53,92 46,53,92 46,53,92 46,53,92 46,53,92 46,53,92 46,53,92 46,53,92 46,53,92 dF dF dF MODELINK LZT LCSP LHSP 92 92 92 92 HRS HRS HRS HRS HR_A1 HR_A2 HR_B1 HR_B2 config config config config 92 92 92 92 CY_A1 CY_A2 CY_B1 CY_B2 config config config config 92 92 92 92 ON/OFF 140 ECONOPOS ECONOCMD ECACTIVE forcible PAGE NO. 46,47,49,90,92 46,47,63,90,92 46,47,90,92 46,47,90,92 46-48,90,92 46,47,90,92 46,47,90,92 43,46,47,90,92 46,47,90,92 46,47,90,92 46,47,90,92 46,47,90,92 46,47,91,92 46,47,91,92 46,47,91,92 46,47,91,92 46,47,91,92 47,91,92 % ^F ^F 0-999999 0-999999 0-999999 0-999999 string OCCUPIED MAT EDT LAT ECONCPNT ECONOPOS COOLCPNT CAPTOTAL HEATCPNT HT_STAGE HTMAXSTG WRITE STATUS ECONUNAV ECONDISA DBC_STAT DEW_STAT DDBCSTAT OAECSTAT DEC_STAT EDT_STAT OAT_STAT ECONFORC SFONSTAT COOL_OFF OAQLOCKD ECONHELD DHDISABL dF % 0-999999 0-999999 0-999999 0-999999 CCN POINT forcible APPENDIX A — LOCAL DISPLAY TABLES (cont) MODE — RUN STATUS (cont) ITEM TMGD TG.A1 TG.A2 TG.B1 TG.B2 TG.H1 TG.H2 TG.H3 TG.H4 TG.H5 TG.H6 VERS MBB ECB1 ECB2 SCB CEM MARQ NAVI EXPANSION TIMEGUARDS Compressor A1 Timeguard Compressor A2 Timeguard Compressor B1 Timeguard Compressor B2 Timeguard Heat Relay 1 Timeguard Heat Relay 2 Timeguard Heat Relay 3 Timeguard Heat Relay 4 Timeguard Heat Relay 5 Timeguard Heat Relay 6 Timeguard SOFTWARE VERSION NUMBERS CESR131343-xx-xx CESR131249-xx-xx CESR131249-xx-xx CESR131226-xx-xx CESR131174-xx-xx CESR131171-xx-xx CESR130227-xx-xx RANGE UNITS CCN POINT WRITE STATUS PAGE NO. CMPA1_TG CMPA2_TG CMPB1_TG CMPB2_TG HS1_TG HS2_TG HS3_TG HS4_TG HS5_TG HS6_TG 93 93 93 93 93 93 93 93 93 93 string string string string string string string 93 93 93 93 93 93 93 MODE — SERVICE TEST ITEM TEST STOP S.STP FAN.F F.4.CH INDP ECN.C E.PWR E.CAL PE.A PE.B PE.C H.I.R ALRM FANS S.FAN S.VFD CD.F.A CD.F.B COOL A1 A2 MLV B1 B2 HEAT HT.ST HT.1 HT.2 HT.3 HT.4 HT.5 HT.6 EXPANSION Service Test Mode Local Machine Disable Soft Stop Request Supply Fan Request 4 in. Filter Change Mode TEST INDEPENDENT OUTPUTS Economizer Act.Cmd.Pos. Economizer Power Test Calibrate the Economizer? Power Exhaust Relay A Power Exhaust Relay B Power Exhaust Relay C Heat Interlock Relay Remote Alarm/Aux Relay TEST FANS Supply Fan Relay Supply Fan VFD Speed Condenser Fan Circuit A Condenser Fan Circuit B TEST COOLING Compressor A1 Relay Compressor A2 Relay Min. Load Valve (HGBP) Compressor B1 Relay Compressor B2 Relay TEST HEATING Requested Heat Stage Heat Relay 1 Heat Relay 2 Relay 3 W1 Gas Valve 2 Relay 4 W2 Gas Valve 2 Relay 5 W1 Gas Valve 3 Relay 6 W2 Gas Valve 3 RANGE ON/OFF YES/NO YES/NO YES/NO YES/NO UNITS CCN POINT MAN_CTRL UNITSTOP SOFTSTOP SFANFORC FILT4CHG WRITE STATUS config forcible forcible PAGE NO. 27,29,30 29,30 29,30 29,30 ECONCTST ECONPTST ECON_CAL PE_A_TST PE_B_TST PE_C_TST HIR_TST ALRM_TST 30 30 30 30 30 30 30 30 SFAN_TST SGVFDTST CNDA_TST CNDB_TST 30 30 30 30 ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF CMPA1TST CMPA2TST MLV_TST CMPB1TST CMPB2TST 30 30 30 30 30 0-MAX ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF HTST_TST HS1_TST HS2_TST HS3_TST HS4_TST HS5_TST HS6_TST 30 30 30 30 30 30 30 ON/OFF ON/OFF ON/OFF 0-100 ON/OFF ON/OFF % MODE — TEMPERATURES ITEM AIR.T CTRL CTRLEDT CTRLLAT CTRLMAT CTRLR.TMP CTRLS.TMP SAT OAT RAT SPT SPTO S.G.LS S.G.L1 S.G.L2 S.G.L3 S.G.LM REF.T SCT.A SST.A SCT.B SST.B EXPANSION AIR TEMPERATURES CONTROL TEMPS Evaporator Discharge Tmp Leaving Air Temperature Mixed Air Temperature Controlling Return Temp Controlling Space Temp Air Tmp Lvg Supply Fan Outside Air Temperature Return Air Temperature Space Temperature Space Temperature Offset Staged Gas LAT Sum Staged Gas LAT 1 Staged Gas LAT 2 Staged Gas LAT 3 Staged Gas Limit Sw.Temp REFRIGERANT TEMPERATURES Cir A Sat.Condensing Tmp Cir A Sat.Suction Temp. Cir B Sat.Condensing Tmp Cir B Sat.Suction Temp. RANGE –40 - 240 –40 - 240 141 UNITS CCN POINT dF dF dF dF dF dF dF dF dF ^F dF dF dF dF dF EDT LAT MAT RETURN_T SPACE_T SAT OAT RAT SPT SPTO LAT_SGAS LAT1SGAS LAT2SGAS LAT3SGAS LIMSWTMP dF dF dF dF SCTA SSTA SCTB SSTB WRITE STATUS forcible forcible forcible forcible forcible forcible APPENDIX A — LOCAL DISPLAY TABLES (cont) MODE — PRESSURES ITEM AIR.P SP BP REF.P DP.A SP.A DP.B SP.B EXPANSION AIR PRESSURES Static Pressure Building Pressure REFRIGERANT PRESSURES Cir A Discharge Pressure Cir A Suction Pressure Cir B Discharge Pressure Cir B Suction Pressure RANGE UNITS CCN POINT "H2O "H2O SP BP PSIG PSIG PSIG PSIG DP_A SP_A DP_B SP_B WRITE STATUS MODE — SET POINTS ITEM OHSP OCSP UHSP UCSP GAP V.C.ON V.C.OF SASP SA.HI SA.LO SA.HT T.PRG T.CL T.V.OC T.V.UN DESCRIPTION Occupied Heat Setpoint Occupied Cool Setpoint Unoccupied Heat Setpoint Unoccupied Cool Setpoint Heat-Cool Setpoint Gap VAV Occ. Cool On Delta VAV Occ. Cool Off Delta Supply Air Setpoint Supply Air Setpoint Hi Supply Air Setpoint Lo Heating Supply Air Setpt Tempering Purge SASP Tempering in Cool SASP Tempering Vent Occ SASP Tempering Vent Unocc. SASP RANGE 40-99 40-99 40-99 40-99 2-10 0-25 1-25 45-75 45-75 45-75 80-120 –20-80 5-75 –20-80 –20-80 UNITS dF dF dF dF ^F ^F ^F dF dF dF dF dF dF dF dF CCN POINT OHSP OCSP UHSP UCSP HCSP_GAP VAVOCON VAVOCOFF SASP SASP_HI SASP_LO SASPHEAT TEMPPURG TEMPCOOL TEMPVOCC TEMPVUNC DEFAULT 68 75 55 90 5 3.5 2 55 55 60 85 50 5 65 50 MODE — INPUTS ITEM GEN.I FLT.S G.FAN REMT E.SW E.ENA E.OVR S.FN.S DL.S1 DL.S2 DH.IN FD.BK CS.A1 CS.A2 CS.B1 CS.B2 STAT G W1 W2 Y1 Y2 FIRE FSD PRES EVAC PURG REL.H OA.RH OA.EN OA.DP RA.RH RA.EN AIR.Q IAQ.I IAQ OAQ DAQ IQ.P.O RSET SA.S.R SP.RS EXPANSION GENERAL INPUTS Filter Status Input Fan Request From IGC Remote Input State Economizer Control Input Remote Economizer Enable Econo Position Override Supply Fan Status Switch Demand Limit Switch 1 Demand Limit Switch 2 Dehumidify Switch Input COMPRESSOR FEEDBACK Compressor A1 Feedback Compressor A2 Feedback Compressor B1 Feedback Compressor B2 Feedback THERMOSTAT INPUTS Thermostat G Input Thermostat W1 Input Thermostat W2 Input Thermostat Y1 Input Thermostat Y2 Input FIRE-SMOKE INPUTS Fire Shutdown Input Pressurization Input Evacuation Input Smoke Purge Input RELATIVE HUMIDITY Outside Air Rel. Humidity Outdoor Air Enthalpy OutsideAir Dewpoint Temp Return Air Rel. Humidity Return Air Enthalpy AIR QUALITY SENSORS IAQ - Discrete Input IAQ - PPM Return CO2 OAQ - PPM Return CO2 Diff.Air Quality in PPM IAQ Min.Pos. Override RESET INPUTS Supply Air Setpnt. Reset Static Pressure Reset RANGE UNITS CCN POINT WRITE STATUS DRTY/CLN ON/OFF * YES/NO YES/NO YES/NO ON/OFF ON/OFF ON/OFF ON/OFF FLTS IGCFAN RMTIN ECOSW ECONENBL ECOORIDE SFS DMD_SW1 DMD_SW2 DHDISCIN ON/OFF ON/OFF ON/OFF ON/OFF CSB_A1 CSB_A2 CSB_B1 CSB_B2 ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF G W1 W2 Y1 Y2 forcible forcible forcible forcible forcible ALARM/NORMAL ALARM/NORMAL ALARM/NORMAL ALARM/NORMAL FSD PRES EVAC PURG forcible forcible forcible forcible OARH OAE OADEWTMP RARH RAE forcible % dF % HIGH/LOW % ^F forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible IAQIN IAQ OAQ DAQ IAQMINOV forcible forcible forcible SASPRSET SPRESET forcible forcible forcible *The display text changes depending on the remote switch configuration (ConfigurationUNITRM.CF). If RM.CF is set to 0 (No Remote Switch), then the display text will be “On” or “Off.” If RM.CF is set to 1 (Occupied/Unoccupied Switch), then the display text will be “Occupied” or “Unoccupied.” If RM.CF is set to 2 (Start/Stop), then the display text will be “Stop” or “Start.” If RM.CF is set to 3 (Override Switch), then the display text will be “No Override” or “Override.” 142 APPENDIX A — LOCAL DISPLAY TABLES (cont) MODE — INPUTS (cont) ITEM 4-20 IAQ.M OAQ.M SP.R.M DML.M EDR.M ORH.M RRH.M BP.M BP.M.T SP.M SP.M.T EXPANSION 4-20 MILLIAMP INPUTS IAQ Milliamps OAQ Milliamps SP Reset milliamps 4-20 ma Demand Signal EDT Reset Milliamps OARH Milliamps RARH Milliamps BP Milliamps Bldg. Pressure Trim (ma) SP Milliamps Static Press. Trim (ma) RANGE UNITS ma ma ma ma ma ma ma ma CCN POINT WRITE STATUS IAQ_MA OAQ_MA SPRST_MA DMDLMTMA EDTRESMA OARH_MA RARH_MA BP_MA BPMATRIM SP_MA SPMATRIM –2.0 - 2.0 ma –2.0 - 2.0 forcible config config *The display text changes depending on the remote switch configuration (ConfigurationUNITRM.CF). If RM.CF is set to 0 (No Remote Switch), then the display text will be “On” or “Off.” If RM.CF is set to 1 (Occupied/Unoccupied Switch), then the display text will be “Occupied” or “Unoccupied.” If RM.CF is set to 2 (Start/Stop), then the display text will be “Stop” or “Start.” If RM.CF is set to 3 (Override Switch), then the display text will be “No Override” or “Override.” MODE — OUTPUTS ITEM FANS S.FAN S.VFD P.E.A P.E.B P.E.C CD.F.A CD.F.B COOL A1 A2 MLV B1 B2 HEAT HT.1 HT.2 HT.3 HT.4 HT.5 HT.6 H.I.R ECON ECN.P ECN.C E.PWR GEN.O ALRM EXPANSION FANS Supply Fan Relay Supply Fan VFD Speed Power Exhaust Relay A Power Exhaust Relay B Power Exhaust Relay C Condenser Fan Circuit A Condenser Fan Circuit B COOLING Compressor A1 Relay Compressor A2 Relay Min. Load Valve (HGBP) Compressor B1 Relay Compressor B2 Relay HEATING Heat Relay 1 Heat Relay 2 Relay 3 W1 Gas Valve 2 Relay 4 W2 Gas Valve 2 Relay 5 W1 Gas Valve 3 Relay 6 W2 Gas Valve 3 Heat Interlock Relay ECONOMIZER Economizer Act.Curr.Pos. Economizer Act.Cmd.Pos. Economizer Power Relay GENERAL OUTPUTS Remote Alarm/Aux Relay RANGE ON/OFF 0-100 ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF UNITS CCN POINT WRITE STATUS SFAN_RLY SFAN_VFD PE_A PE_B PE_C CONDFANA CONDFANB % ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF CMPA1 CMPA2 MLV CMPB1 CMPB2 ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF HS1 HS2 HS3 HS4 HS5 HS6 HIR forcible ECONOPOS ECONOCMD ECON_PWR forcible forcible ALRM forcible 0-100 0-100 ON/OFF % % ON/OFF MODE — CONFIGURATION ITEM UNIT C.TYP CV.FN RM.CF CEM TCS.C TCS.H SFS.S SFS.M VAV.S SIZE DP.XR SP.XR RFG.T CND.T MAT.S MAT.R MAT.D ALTI DLAY STAT AUX.R SENS SENSSPT.S SENSSP.O.S SENSSP.O.R SENSRRH.S SENSFLT.S EXPANSION UNIT CONFIGURATION Machine Control Type Fan Mode (0=Auto, 1=Cont) Remote Switch Config CEM Module Installed Temp.Cmp.Strt.Cool Factr Temp.Cmp.Strt.Heat Factr Fan Fail Shuts Down Unit Fan Stat Monitoring Type VAV Unocc.Fan Retry Time Unit Size (20-60) Disch.Press. Transducers Suct. Pres. Trans. Type Refrig: 0=R22 1=R410A Cnd HX Typ:0=RTPF 1=MCHX MAT Calc Config Reset MAT Table Entries? MAT Outside Air Default Altitude……..in feet: Startup Delay Time TSTAT-Both Heat and Cool Auxiliary Relay Config INPUT SENSOR CONFIG Space Temp Sensor Space Temp Offset Sensor Space Temp Offset Range Return Air RH Sensor Filter Stat.Sw.Enabled ? RANGE UNITS CCN POINT DEFAULT 1 - 6 (multi-text strings) CTRLTYPE 4 0 - 1 (multi-text strings) 0 - 3 (multi-text strings) Yes/No 0 - 60 0 - 60 Yes/No 0 - 2 (multi-text strings) 0 - 720 20 - 60 Yes/No 0 - 1 (multi-text strings) 0 - 1 (multi-text strings) 0 - 1 (multi-text strings) 0 - 2 (multi-text strings) Yes/No 0-100 0 - 60000 0 - 900 Yes/No 0-3 FAN_MODE RMTINCFG CEM_BRD TCSTCOOL TCSTHEAT SFS_SHUT SFS_MON SAMPMINS UNITSIZE DP_TRANS SPXRTYPE REFRIG_T COILTYPE MAT_SEL MATRESET MATOADOS ALTITUDE DELAY TSTATALL AUXRELAY 1 0 No 0 0 No 0 50 20 No 0 1 0 1 No 20 0 0 No 0 SPTSENS SPTOSENS SPTO_RNG RARHSENS FLTS_ENA Disable Disable 5 Disable Disable Enable/Disable Enable/Disable 1 - 10 Enable/Disable Enable/Disable 143 min min min % sec PAGE NO. 27,28,32,35-37, 63,75,96 27,28,35,36 31,35,36,74 35,36 35,36 36 36,60,100 35,36,60,100 36 36,38,42,49 36,97 36 36,38,49 36,38,49 36,47,48 36,47,48 36,37 36,37 36,37 36,37 36,37 36 27,28,36,37 36,37,75 36,37,75 36,37,61,97,99 36,37,60,100 APPENDIX A — LOCAL DISPLAY TABLES (cont) MODE — CONFIGURATION (cont) ITEM COOL Z.GN MC.LO C.FOD MLV M.M. HPSP A1.EN A2.EN B1.EN B2.EN CS.A1 CS.A2 CS.B1 CS.B2 REV.R H.SST EDT.R RS.CF RTIO LIMT RES.S HEAT HT.CF HT.SP OC.EN LAT.M G.FOD E.FOD SG.CF SG.CFHT.ST SG.CFCAP.M SG.CFM.R.DB SG.CFS.G.DB SG.CFRISE SG.CFLAT.L SG.CFLIM.M SG.CFSW.H.T SG.CFSW.L.T SG.CFHT.P SG.CFHT.D SG.CFHT.TM SP SP.CF SP.FN SP.S SP.LO SP.HI SP.SP SP.MN SP.MX SP.FS SP.RS SP.RT SP.LM SP.EC S.PID S.PID->SP.TM S.PID->SP.P S.PID->SP.I S.PID->SP.D S.PID->SP.SG ECON EC.EN EC.MN EC.MX EXPANSION COOLING CONFIGURATION Capacity Threshold Adjst Compressor Lockout Temp Fan-Off Delay, Mech Cool Min. Load Valve? (HGBP) Motor Master Control Head Pressure Setpoint Enable Compressor A1 Enable Compressor A2 Enable Compressor B1 Enable Compressor B2 CSB A1 Feedback Alarm CSB A2 Feedback Alarm CSB B1 Feedback Alarm CSB B2 Feedback Alarm Rev Rotation Verified ? Hi SST Alert Delay Time EVAP.DISCHRGE TEMP RESET EDT Reset Configuration Reset Ratio Reset Limit EDT 4-20 ma Reset Input HEATING CONFIGURATION Heating Control Type Heating Supply Air Setpt Occupied Heating Enabled MBB Sensor Heat Relocate Fan-Off Delay, Gas Heat Fan-Off Delay, Elec Heat STAGED GAS CONFIGS Staged Gas Heat Type Max Cap Change per Cycle S.Gas DB min.dF/PID Rate St.Gas Temp. Dead Band Heat Rise dF/sec Clamp LAT Limit Config Limit Switch Monitoring? Limit Switch High Temp Limit Switch Low Temp Heat Control Prop. Gain Heat Control Derv. Gain Heat PID Rate Config SUPPLY STATIC PRESS.CFG. Static Pressure Config Static Pres.Fan Control? Static Pressure Sensor Static Press. Low Range Static Press. High Range Static Pressure Setpoint VFD Minimum Speed VFD Maximum Speed VFD Fire Speed Override Stat. Pres. Reset Config SP Reset Ratio (/dF) SP Reset Limit in iwc() SP Reset Econo.Position STAT.PRESS.PID CONFIGS Stat.Pres.PID Run Rate Static Press. Prop. Gain Static Pressure Intg. Gain Static Pressure Derv. Gain Static Press.System Gain ECONOMIZER CONFIGURATION Economizer Installed? Economizer Min.Position Economizer Max.Position E.TRM E.SEL OA.E.C OA.EN OAT.L O.DEW ORH.S E.TYP EC.SW E.CFG E.CFGE.P.GN E.CFGE.RNG E.CFGE.SPD E.CFGE.DBD UEFC UEFCFC.CF UEFCFC.TM UEFCFC.L.O Economzr Trim For SumZ ? Econ ChangeOver Select OA Enthalpy ChgOvr Selct Outdr.Enth Compare Value High OAT Lockout Temp OA Dewpoint Temp Limit Outside Air RH Sensor Economizer Control Type Economizer Switch Config ECON.OPERATION CONFIGS Economizer Prop.Gain Economizer Range Adjust Economizer Speed Adjust Economizer Deadband UNOCC.ECON.FREE COOLING Unoc Econ Free Cool Cfg Unoc Econ Free Cool Time Un.Ec.Free Cool OAT Lock RANGE –10 - 10 –20 - 55 0 - 600 Yes/No Yes/No 80 - 150 Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Yes/No 5 - 30 0 - 3 (multi-text strings) 0 - 10 0 - 20 Enable/Disable 0-4 80 - 120 Yes/No Yes/No 45-600 10-600 0-4 5 - 45 0-5 0-5 0.05 - 0.2 0 - 20 Yes/No 110 - 180 100 - 170 0 - 1.5 0 - 1.5 60 - 300 0 - 1 (multi-text strings) Yes Enable/Disable –10 - 0 0 - 10 0-5 0 - 100 0 - 100 0 - 100 0-4 (multi-text strings) 0 - 2.00 0 - 2.00 0 - 100 1 - 200 0 - 100 0 - 50 0 - 50 0 - 50 Yes/No 0 - 100 0 - 100 Yes/No 0 - 3 (multi-text strings) 1 - 5 (multi-text strings) 18 - 28 -40 - 120 50 - 62 Enable/Disable 1-3 (multi-text strings) 0 - 2 (multi-text strings) UNITS dF sec dF min ^F dF ^F ^F dF dF sec "H2O % % % % sec % % dF dF CCN POINT 1 40 60 No No 113 Enable Enable Enable Enable Enable Enable Enable Enable No 10 39,46,91 39,48 39 39,75 39,49 39,49 39 39 39 39 39,100 39,100 39,100 39,100 39,98 39,97 EDRSTCFG RTIO LIMT EDTRSENS 0 2 10 Disable 28,38 28,38 28,38 28,35,38,96 HEATTYPE SASPHEAT HTOCCENA HTLATMON GAS_FOD HEAT_FOD 0 85 No No 45 30 50,51,56,71 50,51 51 51 51 51 HTSTGTYP HTCAPMAX HT_MR_DB HT_SG_DB HTSGRISE HTLATLIM HTLIMMON HT_LIMHI HT_LIMLO HT_PGAIN HT_DGAIN HTSGPIDR 0 45 0.5 2 0.06 10 No 170 160 1 1 90 51,53-56 51,53,54 51,53,54 51,53,54 51,53,54 51,53,54 51,53,54 51,53,54 51,53,54 51,53,54 51,53,54 51,53,54 STATICFG STATPFAN SPSENS SP_LOW SP_HIGH SPSP STATPMIN STATPMAX STATPFSO SPRSTCFG SPRRATIO SPRLIMIT ECONOSPR No Yes Disable 0 5 1.5 20 100 100 0 0.2 0.75 5 SPIDRATE STATP_PG STATP_IG STATP_DG STATP_SG 2 20 2 0 1 31,57,58,60 57,58 57,58 57,58 57,58 28,57,58 58 58 58,67 31,58,59 58 58 58 58,59 58,59 58,59 58,59 58,59 58,59 ECON_ENA ECONOMIN ECONOMAX Yes 5 98 ECONTRIM ECON_SEL OAEC_SEL OAEN_CFG OAT_LOCK OADEWCFG OARHSENS ECON_CTL ECOSWCFG Yes 1 4 24 60 55 Disable 1 0 28,60,62 28,60,62 28,42,43,50,60, 62 28,48,60,62 28,61,62 28,61,62 28,61,62 28,61,62 28,61,62 28,61,62,96 61,62 61,62 1 2.5 0.75 0.5 62 62 62 62 0 120 50 62 62 62 ^F EC_PGAIN EC_RANGE EC_SPEED EC_DBAND 0-2 (multi-text strings) 0 - 720 40 - 70 min dF UEFC_CFG UEFCTIME UEFCNTLO 144 PAGE NO. Z_GAIN OATLCOMP COOL_FOD MLV_SEL MOTRMAST HPSP CMPA1ENA CMPA2ENA CMPB1ENA CMPB2ENA CSB_A1EN CSB_A2EN CSB_B1EN CSB_B2EN REVR_VER HSSTTIME 0.7 - 3.0 0.5 - 5.0 0.1 - 10.0 0.1 - 2.0 ^F DEFAULT APPENDIX A — LOCAL DISPLAY TABLES (cont) MODE — CONFIGURATION (cont) ITEM BP BP.CF BP.RT BP.P BP.I BP.D BP.SO BP.MN BP.MX BP.FS BP.MT BP.S BP.R BP.SP BP.P1 BP.P2 B.CFG B.CFGBP.SL B.CFGBP.TM B.CFGBP.ZG B.CFGBP.HP B.CFGBP.LP D.LV.T L.H.ON H.H.ON L.H.OF L.C.ON H.C.ON L.C.OF C.T.LV H.T.LV C.T.TM H.T.TM DMD.L DM.L.S D.L.20 SH.NM SH.DL SH.TM D.L.S1 D.L.S2 IAQ DCV.C DCV.CEC.MN DCV.CIAQ.M AQ.CF AQ.CFIQ.A.C AQ.CFIQ.A.F AQ.CFIQ.I.C AQ.CFIQ.I.F AQ.CFOQ.A.C AQ.SP AQ.SPIQ.O.P AQ.SPDAQ.L AQ.SPDAQ.H AQ.SPD.F.OF AQ.SPD.F.ON AQ.SPIAQ.R AQ.SPOAQ.L AQ.SPOAQ.U AQ.S.R AQ.S.RIQ.R.L AQ.S.RIQ.R.H AQ.S.ROQ.R.L AQ.S.ROQ.R.H IAQ.P IAQ.PIQ.PG IAQ.PIQ.P.T IAQ.PIQ.P.L IAQ.PIQ.P.H IAQ.PIQ.L.O DEHU D.SEL D.SEN D.EC.D D.V.CF D.V.RA D.V.HT D.C.SP D.RH.S EXPANSION BUILDING PRESS. CONFIG Building Press. Config Bldg.Pres.PID Run Rate Bldg. Press. Prop. Gain Bldg.Press.Integ.Gain Bldg.Press.Deriv.Gain BP Setpoint Offset BP VFD Minimum Speed BP VFD Maximum Speed VFD/Act. Fire Speed/Pos. Power Exhaust Motors Building Pressure Sensor Bldg Press (+/-) Range Building Pressure Setp. Power Exhaust On Setp.1 Power Exhaust On Setp.2 BP ALGORITHM CONFIGS Modulating PE Alg. Slct. BP PID Evaluation Time BP Threshold Adjustment High BP Level Low BP Level COOL/HEAT SETPT. OFFSETS Dmd Level Lo Heat On Dmd Level(+) Hi Heat On Dmd Level(-) Lo Heat Off Dmd Level Lo Cool On Dmd Level(+) Hi Cool On Dmd Level(-) Lo Cool Off Cool Trend Demand Level Heat Trend Demand Level Cool Trend Time Heat Trend Time DEMAND LIMIT CONFIG. Demand Limit Select Demand Limit at 20 ma Loadshed Group Number Loadshed Demand Delta Maximum Loadshed Time Demand Limit Sw.1 Setpt. Demand Limit Sw.2 Setpt. INDOOR AIR QUALITY CFG. DCV ECONOMIZER SETPOINTS Economizer Min.Position IAQ Demand Vent Min.Pos. AIR QUALITY CONFIGS IAQ Analog Sensor Config IAQ 4-20 ma Fan Config IAQ Discrete Input Config IAQ Disc.In. Fan Config OAQ 4-20ma Sensor Config AIR QUALITY SETPOINTS IAQ Econ Override Pos. Diff.Air Quality LoLimit Diff.Air Quality HiLimit DAQ PPM Fan Off Setpoint DAQ PPM Fan On Setpoint Diff. AQ Responsiveness OAQ Lockout Value User Determined OAQ AIR QUALITY SENSOR RANGE IAQ Low Reference IAQ High Reference OAQ Low Reference OAQ High Reference IAQ PRE-OCCUPIED PURGE IAQ Purge IAQ Purge Duration IAQ Purge LoTemp Min Pos IAQ Purge HiTemp Min Pos IAQ Purge OAT Lockout DEHUMIDIFICATION CONFIG. Dehumidification Config Dehumidification Sensor Econ disable in DH mode? Vent Reheat Setpt Select Vent Reheat RAT offset Vent Reheat Setpoint Dehumidify Cool Setpoint Dehumidify RH Setpoint RANGE 0-3 5-120 0-5 0-2 0-5 0.0 - 0.5 0-100 0-100 0-100 1-2 Enable/Dsable 0 - 1.00 –0.25 -> 0.25 0 - 100 0 - 100 UNITS CCN POINT DEFAULT PAGE NO. “H2O "H2O % % BLDG_CFG BPIDRATE BLDGP_PG BLDGP_IG BLDGP_DG BPSO BLDGPMIN BLDGPMAX BLDGPFSO PWRM BPSENS BP_RANGE BPSP PES1 PES2 0 10 0.5 0.5 0.3 0.05 10 100 100 1 Dsable 0.25 0.05 35 75 1-3 0 - 10 0.1 - 10.0 0 - 1.000 0 - 1.000 min “H2O “H2O “H2O BPSELECT BPPERIOD BPZ_GAIN BPHPLVL BPLPLVL 1 1 1 0.05 0.04 29,64,65 64,65 64,65 64,65 64,65 64,65 64,65 64,65 64,65 64,65 64,65 64,65 29,64,65 29,64,65 29,64,65 64,65 64,65 64,65 64,65 64,65 64-66 –1 - 2 0.5 - 20.0 0.5 - 2 –1 - 2 0.5 - 20.0 0.5 - 2 0.1 - 5 0.1 - 5 30 - 600 30 - 600 ^F ^F ^F ^F ^F ^F ^F ^F sec sec DMDLHON DMDHHON DMDLHOFF DMDLCON DMDHCON DMDLCOFF CTRENDLV HTRENDLV CTRENDTM HTRENDTM 1.5 0.5 1 1.5 0.5 1 0.1 0.1 120 120 27,28,52 27,28,52 27,28,52 27,28,52 27,28,52 27,28,52 52 52 52 52 % min % % DMD_CTRL DMT20MA SHED_NUM SHED_DEL SHED_TIM DLSWSP1 DLSWSP2 0 100 0 0 60 80 50 31,35,48,49,98 31,49 49 49 49 31,49 31,49 % % ECONOMIN IAQMINP 5 0 29,31,32,67-70 29,31,67-70 IAQANCFG IAQANFAN IAQINCFG IAQINFAN OAQANCFG 0 0 0 0 0 32,67,69,70 32,68-70 31,35,67-70 32,68-70 35,68-70 IAQOVPOS DAQ_LOW DAQ_HIGH DAQFNOFF DAQFNON IAQREACT OAQLOCK OAQ_USER 100 100 700 200 400 0 0 400 32,67,69,70,98 68-70 32,68-70 32,68-70 32,68-70 69,70 69,70 32,69,70 IAQREFL IAQREFH OAQREFL OAQREFH 0 2000 0 2000 32,69,70 32,69,70 69,70 69,70 min % % dF IAQPURGE IAQPTIME IAQPLTMP IAQPHTMP IAQPNTLO No 15 10 35 50 69,70 69,70 69,70 69,70 69,70 ^F dF dF % DHSELECT DHSENSOR DHECDISA DHVHTCFG DHVRAOFF DHVHT_SP DHCOOLSP DHRELHSP 0 1 Yes 0 0 70 45 55 69-71 69,70 69,70 70,71 70,71 70,71 70,71 70,71 0 - 3 (multi-text strings) 0 - 100 0 - 99 0 - 60 0 - 120 0 - 100 0 - 100 0 - 100 0 - 100 sec “H2O % % % % 0 - 4 (multi-text strings) 0 - 2 (multi-text strings) 0 - 2 (multi-text strings) 0 - 2 (multi-text strings) 0 - 2 (multi-text strings) 0 - 100 0 - 1000 100 - 2000 0 - 2000 0 - 2000 –5 - 5 0 - 2000 0 - 5000 % 0 - 5000 0 - 5000 0 - 5000 0 - 5000 Yes/No 5-60 0-100 0-100 35-70 0-2 (multi-text strings) 1-2 (multi-text strings) Yes/No 0-1 (multi-text strings) 0-8 55-95 40-55 10-90 145 APPENDIX A — LOCAL DISPLAY TABLES (cont) MODE — CONFIGURATION (cont) ITEM CCN CCNA CCNB BAUD BROD BRODTM.DT BRODOAT.B BRODORH.B BRODOAQ.B BRODG.S.B BRODB.ACK SC.OV SC.OVSCH.N SC.OVHOL.T SC.OVO.T.L. SC.OVOV.EX SC.OVSPT.O SC.OVT58.O SC.OVGL.OV ALLM SP.L.O SP.H.O SP.L.U SP.H.U SA.L.O SA.H.O SA.L.U SA.H.U RA.L.O RA.H.O RA.L.U RA.H.U R.RH.L R.RH.H SP.L SP.H BP.L BP.H IAQ.H TRIM SAT.T RAT.T OAT.T SPT.T CTA.T CTB.T SP.A.T SP.B.T DP.A.T DP.B.T SW.LG FTS.L IGC.L RMI.L ECS.L SFS.L DL1.L DL2.L IAQ.L FSD.L PRS.L EVC.L PRG.L DISP TEST METR LANG PAS.E PASS EXPANSION CCN CONFIGURATION CCN Address CCN Bus Number CCN Baud Rate CCN BROADCST DEFINITIONS CCN Time/Date Broadcast CCN OAT Broadcast CCN OARH Broadcast CCN OAQ Broadcast Global Schedule Broadcst CCN Broadcast Ack'er CCN SCHEDULES-OVERRIDES Schedule Number Accept Global Holidays? Override Time Limit Timed Override Hours SPT Override Enabled ? T58 Override Enabled ? Global Sched. Override ? ALERT LIMIT CONFIG. SPT lo alert limit/occ SPT hi alert limit/occ SPT lo alert limit/unocc SPT hi alert limit/unocc EDT lo alert limit/occ EDT hi alert limit/occ EDT lo alert limit/unocc EDT hi alert limit/unocc RAT lo alert limit/occ RAT hi alert limit/occ RAT lo alert limit/unocc RAT hi alert limit/unocc RARH low alert limit RARH high alert limit SP low alert limit SP high alert limit BP lo alert limit BP high alert limit IAQ high alert limit SENSOR TRIM CONFIG. Air Temp Lvg SF Trim RAT Trim OAT Trim SPT Trim Cir A Sat.Cond.Temp Trim Cir B Sat.Cond.Temp Trim Suct.Press.Circ.A Trim Suct.Press.Circ.B Trim Dis.Press.Circ.A Trim Dis.Press.Circ.B Trim SWITCH LOGIC: NO / NC Filter Status Inpt-Clean IGC Feedback - Off RemSw Off-Unoc-Strt-NoOv Economizer Switch - No Fan Status Sw. - Off Dmd.Lmt.Sw.1 - Off Dmd.Lmt.Sw.2 - Dehumid - Off IAQ Disc.Input - Low Fire Shutdown - Off Pressurization Sw. - Off Evacuation Sw. - Off Smoke Purge Sw. - Off DISPLAY CONFIGURATION Test Display LEDs Metric Display Language Selection Password Enable Service Password RANGE UNITS CCN POINT DEFAULT PAGE NO. 1 - 239 0 - 239 1 - 5 (multi-text strings) CCNADD CCNBUS CCNBAUDD 1 0 3 71,72 71,72 71,72 ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF CCNBC OATBC OARHBC OAQBC GSBC CCNBCACK On Off Off Off Off Off 71,72 71,72 71,72 71,72 71,72 71,72 0 - 99 YES/NO 0-4 0-4 YES/NO YES/NO YES/NO SCHEDNUM HOLIDAYT OTL OVR_EXT SPT_OVER T58_OVER GLBLOVER 1 No 1 0 Yes Yes No 27-29,71,72 72 27,72 72 27,72 27,72 72 HRS HRS –10-245 –10-245 –10-245 –10-245 –40-245 –40-245 –40-245 –40-245 –40-245 –40-245 –40-245 –40-245 0-100 0-100 0-5 0-5 –0.25-0.25 –0.25-0.25 0-5000 dF dF dF dF dF dF dF dF dF dF dF dF % % "H2O "H2O "H2O "H2O SPLO SPHO SPLU SPHU SALO SAHO SALU SAHU RALO RAHO RALU RAHU RRHL RRHH SPL SPH BPL BPH IAQH 60 85 45 100 40 100 40 100 60 90 40 100 0 100 0 2 -0.25 0.25 1200 72,73,98 72,73,99 72,73,98 72,73,99 43,72,73,99 72,73,99 72,73,99 72,73,99 72,73,99 72,73,99 72,73,99 72,73,99 72,73,99 72,73,99 73,99 73,99 73,99 73,99 73,99 –10 - 10 –10 - 10 –10 - 10 –10 - 10 –30 - 30 –30 - 30 –50 - 50 –50 - 50 –50 - 50 –50 - 50 ^F ^F ^F ^F ^F ^F PSIG PSIG PSIG PSIG SAT_TRIM RAT_TRIM OAT_TRIM SPT_TRIM SCTATRIM SCTBTRIM SPA_TRIM SPB_TRIM DPA_TRIM DPB_TRIM 0 0 0 0 0 0 0 0 0 0 73 73 73 73 73 73 73 73 73,74 73,74 Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close FLTSLOGC GASFANLG RMTINLOG ECOSWLOG SFSLOGIC DMD_SW1L DMD_SW2L IAQINLOG FSDLOGIC PRESLOGC EVACLOGC PURGLOGC Open Open Open Open Open Open Open Open Open Open Open Open 74,75 74,75 31,74,75 74,75 74,75,100 31,74,75 31,74,75 31,32,74,75 74,75,99 74,75 74,75 74,75 ON/OFF ON/OFF 0-1(multi-text strings) ENABLE/DISABLE 0000-9999 TEST DISPUNIT LANGUAGE PASS_EBL PASSWORD Off Off 0 Enable 1111 74,75 74,75 74,75 74,75 74,75 146 APPENDIX A — LOCAL DISPLAY TABLES (cont) MODE — TIME CLOCK ITEM TIME HH.MM DATE MNTH DOM DAY YEAR SCH.L PER.1 PER.1DAYS PER.1DAYSMON PER.1DAYSTUE PER.1DAYSWED PER.1DAYSTHU PER.1DAYSFRI PER.1DAYSSAT PER.1DAYSSUN PER.1DAYSHOL PER.1OCC PER.1UNC Repeated for periods 2-8……….. HOL.L HD.01 HD.01MON HD.01DAY HD.01LEN Repeated for holidays 2-30…….. DAY.S DS.ST DS.STST.MN DS.STST.WK DS.STST.DY DS.STMIN.A DS.SP DS.SPSP.MN DS.SPSP.WK DS.SPSP.DY DS.SPMIN.S EXPANSION TIME OF DAY Hour and Minute MONTH,DATE,DAY AND YEAR Month of Year Day of Month Day of Week Year LOCAL TIME SCHEDULE PERIOD 1 DAY FLAGS FOR PERIOD 1 Monday in Period Tuesday in Period Wednesday in Period Thursday in Period Friday in Period Saturday in Period Sunday in Period Holiday in Period Occupied from Occupied to LOCAL HOLIDAY SCHEDULES HOLIDAY SCHEDULE 01 Holiday Start Month Start Day Duration (Days) DAYLIGHT SAVINGS TIME DAYLIGHT SAVINGS START Month Week Day Minutes to Add DAYLIGHTS SAVINGS STOP Month Week Day Minutes to Subtract RANGE UNITS CCN POINT DEFAULT PAGE NO. 00:00 TIME 75,77 multi-text strings 0-31 multi-text strings e.g. 2003 MOY DOM DOWDISP YOCDISP 75,77 75,77 75,77 75,77 27,28,75,77 YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO YES/NO 00:00 00:00 PER1MON PER1TUE PER1WED PER1THU PER1FRI PER1SAT PER1SUN PER1HOL PER1_OCC PER1_UNC 0-12 0-31 0-99 HOL_MON1 HOL_DAY1 HOL_LEN1 1 - 12 1-5 1-7 0 - 90 STARTM STARTW STARTD MINADD 4 1 7 60 76,77 76,77 76,77 76,77 1 - 12 1-5 1-7 0 - 90 STOPM STOPW STOPD MINSUB 10 5 7 60 76,77 76,77 76,77 76,77 Period 1 only Yes Yes Yes Yes Yes Yes Yes Yes 00:00 24:00 76,77 76,77 76,77 76,77 76,77 76,77 76,77 76,77 76,77 76,77 76,77 76,77 76,77 76,77 MODE — OPERATING MODES ITEM SYS.M HVAC CTRL MODE OCC T.OVR DCV SA.R DMD.L T.C.ST IAQ.P LINK LOCK H.NUM EXPANSION ascii string spelling out the system mode ascii string spelling out the hvac modes ascii string spelling out the “control type” MODES CONTROLLING UNIT Currently Occupied Timed Override in Effect DCV Resetting Min Pos Supply Air Reset Demand Limit in Effect Temp.Compensated Start IAQ Pre-Occ Purge Active Linkage Active - CCN Mech.Cooling Locked Out HVAC Mode Numerical Form RANGE UNITS CCN POINT string string string ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF 0-24 MODEOCCP MODETOVR MODEADCV MODESARS MODEDMLT MODETCST MODEIQPG MODELINK MODELOCK MODEHVAC MODE — ALARMS ITEM CURR R.CUR HIST EXPANSION CURRENTLY ACTIVE ALARMS this is a dynamic list of active alarms Reset All Current Alarms ALARM HISTORY this is a record of the last 20 alarms RANGE YES/NO UNITS CCN POINT strings ALRESET strings 147 WRITE STATUS ram config APPENDIX B — CCN TABLES In the following tables the structure of the tables which are used with the Service Tool as well as the names and data that are included in each table are shown. As a reference the equivalent scrolling marquee tables and names are included. There are several CCN variables that are not displayed through the scrolling marquee and are used for more extensive diagnostics and system evaluations. All A Series units with ComfortLink™ controls have a port for interface with the Carrier Comfort Network® (CCN) system. On TB3 there is a J11 jack which can be used for temporary connection to the CCN network or to computers equipped with CCN software like the Service Tool. Also on TB3 there are screw connections that can be used for more permanent CCN connections. STATUS DISPLAY TABLES TABLE COOLING DISPLAY NAME HVAC Mode…………..: Control Mode………..: RANGE UNITS POINT NAME WRITE STATUS ascii text strings ascii text strings Current Running Capacity Cooling Control Point Evaporator Discharge Tmp Mixed Air Temperature % dF dF dF CAPTOTAL COOLCPNT EDT MAT PSIG PSIG dF dF CMPA1 CSB_A1 CMPA1_TG CMPA2 CSB_A2 CMPA2_TG MLV DP_A SP_A SCTA SSTA PSIG PSIG dF dF CMPB1 CSB_B1 CMPB1_TG CMPB2 CSB_B2 CMPB2_TG DP_B SP_B SCTB SSTB COOL_A Compressor A1 Relay Compressor A1 Feedback Compressor A1 Timeguard Compressor A2 Relay Compressor A2 Feedback Compressor A2 Timeguard Minimum Load Valve Cir A Discharge Pressure Cir A Suction Pressure Cir A Sat.Condensing Tmp Cir A Sat.Suction Temp. COOL_B Compressor B1 Relay Compressor B1 Feedback Compressor B1 Timeguard Compressor B2 Relay Compressor B2 Feedback Compressor B2 Timeguard Cir B Discharge Pressure Cir B Suction Pressure Cir B Sat.Condensing Tmp Cir B Sat.Suction Temp. ECONDIAG Economizer Active ? Yes/No ECACTIVE Conditions which prevent economizer being active: Econ Act. Unavailable? Remote Econ. Disabled ? DBC - OAT lockout? DEW - OA Dewpt. lockout? DDBC- OAT > RAT lockout? OAEC- OA Enth Lockout? DEC - Diff.Enth.Lockout? EDT Sensor Bad ? OAT Sensor Bad ? Economizer forced ? Supply Fan not on 30s ? Cool Mode not in effect? OAQ lockout in effect ? Econ recovery hold off? Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No ECONUNAV ECONDISA DBC_STAT DEW_STAT DDBCSTAT OAECSTAT DEC_STAT EDT_STAT OAT_STAT ECONFORC SFONSTAT COOL_OFF OAQLOCKD ECONHELD ECONOMZR Economizer Act.Curr.Pos. Economizer Act.Cmd.Pos. % % ECONOPOS ECONOCMD Economizer Active ? Economizer Control Point dF ECACTIVE ECONCPNT Outside Air Temperature Evaporator Discharge Tmp Controlling Return Temp dF dF dF OAT EDT RETURN_T 148 forcible forcible forcible APPENDIX B — CCN TABLES (cont) STATUS DISPLAY TABLES (cont) TABLE GENERAL DISPLAY NAME Occupied ? RANGE UNITS Yes/No POINT NAME OCCUPIED WRITE STATUS forcible Static Pressure Building Pressure "H2O "H2O SP BP Outside Air Rel.Humidity Return Air Rel.Humidity % % OARH RARH forcible forcible Space Temperature Offset Supply Air Setpnt. Reset Static Pressure Reset ^F ^F SPTO SASPRSET SPRESET forcible forcible forcible % IAQ OAQ IAQMINOV forcible forcible forcible dF HT_STAGE HEATCPNT IAQ - PPM Return CO2 OAQ - PPM Return CO2 IAQ Min.Pos.Override GENERIC 20 points dependent upon the configuration of the “generics” table in the Service-Config section on page 155. HEATING HVAC Mode…………..: Control Mode………..: Heat Control Type……: Re-Heat Control Type Heating Mode………..: ascii text strings ascii text strings ascii text strings ascii text strings ascii text strings Current Heat Stage Heating Control Point Heat Relay 1 Heat Relay 2 Relay 3 W1 Gas Valve 2 Relay 4 W2 Gas Valve 2 Relay 5 W1 Gas Valve 3 Relay 6 W2 Gas Valve 3 Heat Interlock Relay HS1 HS2 HS3 HS4 HS5 HS6 HIR Heat Stage 1 Timeguard Heat Stage 2 Timeguard Heat Stage 3 Timeguard Heat Stage 4 Timeguard Heat Stage 5 Timeguard Heat Stage 6 Timeguard HS1_TG HS2_TG HS3_TG HS4_TG HS5_TG HS6_TG forcible MODEDISP System Mode…………: HVAC Mode…………..: Control Mode………..: Currently Occupied Timed Override in effect DCV resetting min pos Supply Air Reset Demand Limit in Effect Temp.Compensated Start IAQ pre-occ purge active Linkage Active - DAV Mech.Cooling Locked Out HVAC Mode Numerical Form ascii text strings ascii text strings ascii text strings On/Off On/Off On/Off On/Off On/Off On/Off On/Off On/Off On/Off number MODEOCCP MODETOVR MODEADCV MODESARS MODEDMLT MODETCST MODEIQPG MODELINK MODELOCK MODEHVAC MODETRIP Unoccup. Cool Mode Start Unoccup. Cool Mode End Occupied Cool Mode Start Occupied Cool Mode End UCCLSTRT UCCL_END OCCLSTRT OCCL_END Ctl.Temp RAT,SPT or Zone CTRLTEMP Occupied Heat Mode End Occupied Heat Mode Start Unoccup. Heat Mode End Unoccup. Heat Mode Start HVAC Mode…………..: OCHT_END OCHTSTRT UCHT_END UCHTSTRT string ascii text strings TEMPCTRL Evaporator Discharge Tmp Leaving Air Temperature Mixed Air Temperature Controlling Return Temp Controlling Space Temp dF dF dF dF dF 149 EDT LAT MAT RETURN_T SPACE_T forcible forcible APPENDIX B — CCN TABLES (cont) STATUS DISPLAY TABLES (cont) TABLE TEMPS DISPLAY NAME RANGE Air Temp Lvg Supply Fan Return Air Temperature Outside Air Temperature Space Temperature Space Temperature Offset Staged Gas LAT Sum Staged Gas LAT 1 Staged Gas LAT 2 Staged Gas LAT 3 Staged Gas Limit Sw.Temp Cir A Sat.Condensing Tmp Cir B Sat.Condensing Tmp Cir A Sat.Suction Temp. Cir B Sat.Suction Temp. UNITS dF dF dF dF ^F dF dF dF dF dF dF dF dF dF POINT NAME SAT RAT OAT SPT SPTO LAT_SGAS LAT1SGAS LAT2SGAS LAT23SGAS LIMSWTMP SCTA SCTB SSTA SSTB WRITE STATUS forcible forcible forcible forcible TSTAT Control Mode………..: ascii text strings Thermostat Y1 Input Thermostat Y2 Input Thermostat W1 Input Thermostat W2 Input Thermostat G Input On/Off On/Off On/Off On/Off On/Off Y1 Y2 W1 W2 G forcible forcible forcible forcible forcible Filter Status Input Fan request from IGC Fire Shutdown Switch Thermostat G Input Thermostat W2 Input Thermostat W1 Input Thermostat Y2 Input Thermostat Y1 Input Economizer Control Input Remote Economizer Enable Econo Position Override Remote Input State Supply Fan Status Switch Demand Limit Switch 1 Demand Limit Switch 2 Pressurization Input Evacuation Input Smoke Purge Input IAQ - Discrete Input Dehumidify Switch Input Dirty/Clean On/Off Alarm/Normal On/Off On/Off On/Off On/Off On/Off On/Off Yes/No Yes/No On/Off On/Off On/Off On/Off Alarm/Normal Alarm/Normal Alarm/Normal High/Low On/Off FLTS IGCFAN FSD G W2 W1 Y2 Y1 ECOSW ECONENBL ECOORIDE RMTIN SFS DMD_SW1 DMD_SW2 PRES EVAC PURG IAQIN DHDISCIN forcible UINPUTS forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible UOUTPUTS FANS Supply Fan Relay Supply Fan VFD Speed Supply Fan Request Power Exhaust Relay A Power Exhaust Relay B Power Exhaust Relay C Condenser Fan A Condenser Fan B COOLING Compressor A1 Relay Compressor A2 Relay Minimum Load Valve Compressor B1 Relay Compressor B2 Relay HEATING Heat Relay 1 Heat Relay 2 Relay 3 W1 Gas Valve 2 Relay 4 W2 Gas Valve 2 Relay 5 W1 Gas Valve 3 Relay 6 W2 Gas Valve 3 Heat Interlock Relay ECONOMIZER Economizer Act.Curr.Pos. Economizer Act.Cmd.Pos. Economizer Power Relay GENERAL OUTPUTS Remote Alarm/Aux Relay On/Off 0-100 Yes/No On/Off On/Off On/Off On/Off On/Off % SFAN_RLY SFAN_VFD SFANFORC PE_A PE_B PE_C CONDFANA CONDFANB forcible On/Off On/Off On/Off On/Off On/Off CMPA1 CMPA2 MLV CMPB1 CMPB2 On/Off On/Off On/Off On/Off On/Off On/Off On/Off HS1 HS2 HS3 HS4 HS5 HS6 HIR forcible ECONOPOS ECONOCMD ECON_PWR forcible forcible ALRM forcible 0-100 0-100 On/Off % % On/Off 150 APPENDIX B — CCN TABLES (cont) SET POINT TABLE TABLE SET_PNT NAME RANGE Occupied Heat Setpoint Occupied Cool Setpoint Unoccupied Heat Setpoint Unoccupied Cool Setpoint Heat-Cool Setpoint Gap VAV Occ. Cool On Delta VAV Occ. Cool Off Delta Supply Air Setpoint Supply Air Setpoint Hi Supply Air Setpoint Lo Heating Supply Air Setpt Tempering Purge SASP Tempering in Cool SASP Tempering in Vent Occ SASP Tempering Vent Unocc. SASP 40-99 40-99 40-99 40-99 2-10 0-25 1-25 45-75 45-75 45-75 80-100 –20-80 5-75 –20-80 –20-80 UNITS POINT NAME dF dF dF dF ^F ^F ^F dF dF dF dF dF dF dF dF OHSP OCSP UHSP UCSP HCSP_GAP VAVOCON VAVOCOFF SASP SASP_HI SASP_LO SASPHEAT TEMPPURG TEMPCOOL TEMPVOCC TEMPVUNC DEFAULT 68 75 55 90 5 3.5 2 55 55 60 85 50 5 65 50 CONFIG TABLES TABLE ALARMDEF NAME RANGE Alarm Routing Control Equipment Priority Comm Failure Retry Time Re-Alarm Time Alarm System Name 00000000-11111111 0-7 1 - 240 1 - 255 up to 8 alphanum CCN Time/Date Broadcast CCN OAT Broadcast CCN OARH Broadcast CCN OAQ Broadcast Global Schedule Broadcst Daylight Savings Start: Month Week Day Minutes to Add Daylight Savings Stop: Month Week Day Minutes to Subtract Device Name: Description: Location: Software Part Number: Model Number: Serial Number: Reference Number: Broadcast Supervisory Holiday Start Month Start Day Duration (days) Occupancy Supervisory Timed Override Hours Period 1 DOW (MTWTFSSH) Occupied From Occupied To Period 2 DOW (MTWTFSSH) Occupied From Occupied To Period 3 DOW (MTWTFSSH) Occupied From Occupied To Period 4 DOW (MTWTFSSH) Occupied From Occupied To Period 5 DOW (MTWTFSSH) Occupied From Occupied To Period 6 DOW (MTWTFSSH) Occupied From Occupied To Period 7 DOW (MTWTFSSH) Occupied From Occupied To Period 8 DOW (MTWTFSSH) Occupied From Occupied To A-Series A Series Rooftop UNITS POINT NAME DEFAULT ALRM_CNT EQP_TYPE RETRY_TM RE-ALARM ALRM_NAM 11000000 5 10 30 A-SERIES Off/On Off/On Off/On Off/On Off/On CCNBC OATBC OARHBC OAQBC GSBC Off Off Off Off Off 1 - 12 1-5 1-7 0 - 90 STARTM STARTW STARTD MINADD 4 1 7 60 1 - 12 1-5 1-7 0 - 90 STOPM STOPW STOPD MINSUB 10 5 7 60 1-12 1-31 1-99 HOL-MON HOL-DAY HOL-LEN 0 0 0 0 00000000 0:00 0:00 00000000 0:00 0:00 00000000 0:00 0:00 00000000 0:00 0:00 00000000 0:00 0:00 00000000 0:00 0:00 00000000 0:00 0:00 00000000 0:00 0:00 OVR-EXT DOW1 OCCTOD1 UNOCTOD1 DOW2 OCCTOD2 UNOCTOD2 DOW3 OCCTOD3 UNOCTOD3 DOW4 OCCTOD4 UNOCTOD4 DOW5 OCCTOD5 UNOCTOD5 DOW6 OCCTOD6 UNOCTOD6 DOW7 OCCTOD7 UNOCTOD7 DOW8 OCCTOD8 UNOCTOD8 min min BRODEFS Ctlr-ID HOLIDAY HOLDY01S to HOLDY30S OCCDEFCS CESR131343-XX-XX 151 APPENDIX B — CCN TABLES (cont) CONFIG TABLES (cont) TABLE SCHEDOVR NAME RANGE Schedule Number Accept Global Holidays? Override Time Limit Timed Override Hours Accepting an Override: SPT Override Enabled ? T58 Override Enabled ? Allowed to Broadcast a Global Sched. Override ? 0-99 Yes/No 0-4 0-4 Occupied Heat Setpoint Occupied Cool Setpoint Unoccupied Heat Setpoint Unoccupied Cool Setpoint Heat-Cool Setpoint Gap VAV Occ. Cool On Delta VAV Occ. Cool Off Delta Supply Air Setpoint Supply Air Setpoint Hi Supply Air Setpoint Lo Heating Supply Air Setpt Tempering Purge SASP 55-80 55-80 40-80 75-95 2-10 0-25 1-25 45-75 45-75 45-75 90-145 –20-80 UNITS POINT NAME DEFAULT SCHEDNUM HOLIDAYT OTL OVR_EXT 0 No 1 0 Yes/No Yes/No SPT_OVER T58_OVER Yes Yes Yes/No GLBLOVER No OHSP OCSP UHSP UCSP HCSP_GAP VAVOCON VAVOCOFF SASP SASP_HI SASP_LO SASPHEAT TEMPPURG 68 75 55 90 5 3.5 2 55 55 60 85 50 hours hours SET_PNT dF dF dF dF ^F ^F ^F dF dF dF dF dF SERVICE-CONFIG TABLES TABLE ALLM NAME RANGE SPT lo alert limit/occ SPT hi alert limit/occ SPT lo alert limit/unocc SPT hi alert limit/unocc EDT lo alert limit/occ EDT hi alert limit/occ EDT lo alert limit/unocc EDT hi alert limit/unocc RAT lo alert limit/occ RAT hi alert limit/occ RAT lo alert limit/unocc RAT hi alert limit/unocc RARH low alert limit RARH high alert limit SP low alert limit SP high alert limit BP lo alert limit BP high alert limit IAQ high alert limit –10-245 –10-245 –10-245 –10-245 –40-245 –40-245 –40-245 –40-245 –40-245 –40-245 –40-245 –40-245 0-100 0-100 0-5 0-5 –0.25-0.25 –0.25-0.25 0-5000 Building Press. Config Bldg.Pres.PID Run Rate Bldg. Press. Prop. Gain Bldg.Press.Integ.Gain Bldg.Press.Deriv.Gain BP Setpoint Offset BP VFD Minimum Speed BP VFD Maximum Speed VFD/Act. Fire Speed/Pos. Power Exhaust Motors 0=None,1=4 Mtr, 2=6 Mtr Building Pressure Sensor Bldg Press (+/-) Range Building Pressure Setp. Power Exhaust On Setp.1 Power Exhaust On Setp.2 Modulating PE Alg. Slct. BP PID Evaluation Time BP Threshold Adjustment High BP Level Low BP Level UNITS dF dF dF dF dF dF dF dF dF dF dF dF % % "H2O "H2O "H2O "H2O POINT NAME DEFAULT SPLO SPHO SPLU SPHU SALO SAHO SALU SAHU RALO RAHO RALU RAHU RRHL RRHH SPL SPH BPL BPH IAQH 60 85 45 100 40 100 40 100 60 90 40 100 0 100 0 2 -0.25 0.25 1200 0-3 5-120 0-5 0-2 0-5 0.0 - 0.5 0-100 0-100 0-100 0-2 BLDG_CFG BPIDRATE BLDGP_PG BLDGP_IG BLDGP_DG BPSO BLDGPMIN BLDGPMAX BLDGPFSO PWRM 0 10 0.5 0.5 0.3 0.05 10 100 100 1 Enable/Disable 0-1 –0.25 -> 0.25 0-100 0-100 1-3 0-10 0.1-10 0-1 0-1 BPSENS BP_RANGE BPSP PES1 PES2 BPSELECT BPPERIOD BPZ_GAIN BPHPLVL BPLPLVL Dsable 0.25 0.05 35 75 1 1 1 0.05 0.04 BP__ 152 "H2O % % min APPENDIX B — CCN TABLES (cont) SERVICE-CONFIG TABLES (cont) TABLE COOL NAME RANGE Capacity Threshold Adjust Compressor Lockout Temp Fan-off Delay, Mech Cool Minimum Load Valve? Motor Master Control ? Head Pressure Setpoint Enable Compressor A1 Enable Compressor A2 Enable Compressor B1 Enable Compressor B2 CSB A1 Feedback Alarm CSB A2 Feedback Alarm CSB B1 Feedback Alarm CSB B2 Feedback Alarm Rev. Rotation Verified ? Hi SST Alert Delay Time –10 -> 10 –20 -> 55 0-600 Yes/No Yes/No 80-150 Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Yes/No 5-30 Dehumidification Config Dehumidification Sensor Econ disable in DH mode? Vent Reheat Setpt Select Vent Reheat RAT offset Vent Reheat Setpoint Dehumidify Cool Setpoint Dehumidify RH Setpoint 0-2 1-2 Yes/No 0-1 0-8 55-95 40-55 10-90 Metric Display Language Selection Password Enable Service Password Contrast Adjustment Brightness Adjustment Off/On 0-1 Enable/Disable 0000-9999 –255 - 255 –255 - 255 Dmd Level Lo Heat On Dmd Level(+) Hi Heat On Dmd Level(-) Lo Heat Off Dmd Level Lo Cool On Dmd Level(+) Hi Cool On Dmd Level(-) Lo Cool Off Cool Trend Demand Level Heat Trend Demand Level Cool Trend Time Heat Trend Time –1 - 2 0.5 - 20.0 0.5 - 2 –1 - 2 0.5 - 20.0 0.5 - 2 0.1 - 5 0.1 - 5 30 - 600 30 - 600 Demand Limit Select Demand Limit at 20 ma Loadshed Group Number Loadshed Demand Delta Maximum Loadshed Time Demand Limit Sw.1 Setpt. Demand Limit Sw.2 Setpt. 0-3 0 - 100 0 - 99 0 - 60 0 - 120 0 - 100 0 - 100 Economizer Installed ? Economizer Min.Position Economizer Max.Position Economzr trim for sumZ ? Econ ChangeOver Select OA Enthalpy ChgOvr Selct Outdr.Enth Compare Value High OAT Lockout Temp OA Dewpoint Temp Limit Outside Air RH Sensor Economizer Control Type Economizer Switch Config Economizer Prop.Gain Economizer Range Adjust Economizer Speed Adjust Economizer Deadband Unoc Econ Free Cool Cfg Unoc Econ Free Cool Time Un.Ec.Free Cool OAT Lock Yes/No 0 - 100 0 - 100 Yes/No 0-3 1-5 18 - 28 55 - 120 50 - 62 Enable/Disable 1-3 0-2 0.7 - 3.0 0.5 - 5 0.1 - 10 0.1 - 2 0-2 0-720 40-70 EDT Reset Configuration Reset Ratio Reset Limit EDT 4-20 ma Reset Input 0-3 0 - 10 0 - 20 Enable/Disable UNITS POINT NAME DEFAULT min Z_GAIN OATLCOMP COOL_FOD MLV_SEL MOTRMAST HPSP CMPA1ENA CMPA2ENA CMPB1ENA CMPB2ENA CSB_A1EN CSB_A2EN CSB_B1EN CSB_B2EN REVR_VER HSSTTIME 1 40 60 No No 110 Enable Enable Enable Enable Enable Enable Enable Enable No 10 ^F dF dF % DHSELECT DHSENSOR DHECONEN DHVHTCFG DHVRAOFF DHVHT_SP DHCOOLSP DHRELHSP 0 1 No 0 0 70 45 55 DISPUNIT LANGUAGE PASS_EBL PASSWORD CNTR_ADJ BRTS_ADJ Off 0 Enable 1111 0 0 DMDLHON DMDHHON DMDLHOFF DMDLCON DMDHCON DMDLCOFF CTRENDLV HTRENDLV CTRENDTM HTRENDTM 1.5 0.5 1 1.5 0.5 1 0.1 0.1 120 120 DMD_CTRL DMT20MA SHED_NUM SHED_DEL SHED_TIM DLSWSP1 DLSWSP2 0 100 0 0 60 80 50 ECON_ENA ECONOMIN ECONOMAX ECONTRIM ECON_SEL OAEC_SEL OAEN_CFG OAT_LOCK OADEWCFG OARHSENS ECON_CTL ECOSWCFG EC_PGAIN EC_RANGE EC_SPEED EC_DBAND UEFC_CFG UEFCTIME UEFCNTLO Yes 20 98 Yes 1 2 24 60 55 Disable 1 0 1 2.5 0.75 0.5 0 120 50 EDRSTCFG RTIO LIMT EDTRSENS 0 2 10 Disable dF sec dF DEHU DISP DLVT ^F ^F ^F ^F ^F ^F ^F ^F sec sec DMDL % % min % % ECON % % dF dF ^F ^F min dF EDTR 153 ^F APPENDIX B — CCN TABLES (cont) SERVICE-CONFIG TABLES (cont) TABLE HEAT NAME RANGE Heating Control Type Heating Supply Air Setpt Occupied Heating Enabled MBB Sensor Heat Relocate Fan-off Delay, Gas Heat Fan-off Delay, Elec Heat Staged Gas Heat Type Max Cap Change per Cycle S.Gas DB min.dF/PID Rate St.Gas Temp. Dead Band Heat Rise dF/sec Clamp LAT Limit Config Heat Control Prop. Gain Heat Control Derv. Gain Heat PID Rate Config 0-4 80-120 Yes/No Yes/No 45-600 10-600 0-4 5 - 45 0-5 0-5 0.05 - 0.2 0 - 20 0 - 1.5 0 - 1.5 60 - 300 Economizer Min.Position IAQ Demand Vent Min.Pos. IAQ Analog Sensor Config IAQ 4-20 ma Fan Config IAQ Discrete Input Config IAQ Disc.In. Fan Config OAQ 4-20ma Sensor Config IAQ Econo Override Pos. Diff.Air Quality LoLimit Diff. Air Quality HiLimit DAQ PPM Fan Off Setpoint DAQ PPM Fan On Setpoint Diff. AQ Responsiveness OAQ Lockout Value User determined OAQ IAQ Low Reference IAQ High Reference OAQ Low Reference OAQ High Reference IAQ Purge IAQ Purge Duration IAQ Purge LoTemp Min Pos IAQ Purge HiTemp Min Pos IAQ Purge OAT Lockout 0 - 100 0 - 100 0-4 0-2 0-2 0-2 0-2 0 - 100 0 - 1000 100 - 2000 0 - 2000 0 - 2000 –5 - 5 0 - 2000 0-5000 0 - 5000 0 - 5000 0 - 5000 0 - 5000 Yes/No 5-60 0-100 0-100 35-70 Static Pres.VFD Control? Static Pres.Fan Control? Static Pressure Sensor Static Press. Low Range Static Press. High Range Static Pressure Setpoint VFD Minimum Speed VFD Maximum Speed VFD Fire Speed Override Stat. Pres. Reset Config SP Reset Ratio ("/dF) SP Reset Limit in iwc(") SP Reset Econo.Position Stat.Pres.PID Run Rate Static Press. Prop. Gain Static Pressure Intg. Gain Static Pressure Derv. Gain Static Press.System Gain No Yes Enable/Disable –10 - 0 0 - 10 0-5 10 - 50 50 - 100 0 - 100 0-4 (multi-text strings) 0 - 2.00 0 - 2.00 0 - 100 1 - 200 0 - 100 0 - 50 0 - 50 0 - 50 Air Temp Lvg SF Trim RAT Trim OAT Trim SPT Trim Cir A Sat.Cond.Temp Trim Cir B Sat.Cond.Temp Trim Suct.Press.Circ.A Trim Suct.Press.Circ.B Trim Dis.Press.Circ.A Trim Dis.Press.Circ.B Trim Static Press. Trim (ma) Bldg. Pressure Trim (ma) –10 - 10 –10 - 10 –10 - 10 –10 - 10 –30 - 30 –30 - 30 –50 - 50 –50 - 50 –50 - 50 –50 - 50 –2 - 2 –2 - 2 UNITS dF ^F ^F sec POINT NAME DEFAULT HEATTYPE SASPHEAT HTOCCENA HTLATMON GAS_FOD ELEC_FOD HTSTGTYP HTCAPMAX HT_MR_DB HT_SG_DB HTSGRISE HTLATLIM HT_PGAIN HT_DGAIN HTSGPIDR 0 85 No No 45 30 0 45 0.5 2 0.06 10 1 1 90 ECONOMIN IAQMINP IAQANCFG IAQANFAN IAQINCFG IAQINFAN OAQANCFG IAQOVPOS DAQ_LOW DAQ_HIGH DAQFNOFF DAQFNON IAQREACT OAQLOCK OAQ_USER IAQREFL IAQREFH OAQREFL OAQREFH IAQPURGE IAQPTIME IAQPLTMP IAQPHTMP IAQPNTLO 5 0 0 0 0 0 0 100 100 700 200 400 0 0 400 0 2000 0 2000 No 15 10 35 50 STATICFG STATPFAN SPSENS SP_LOW SP_HIGH SPSP STATPMIN STATPMAX STATPFSO SPRSTCFG SPRRATIO SPRLIMIT ECONOSPR SPIDRATE STATP_PG STATP_IG STATP_DG STATP_SG No Yes Disable 0 5 1.5 20 100 100 0 0.2 0.75 5 2 20 2 0 1 SAT_TRIM RAT_TRIM OAT_TRIM SPT_TRIM SCTATRIM SCTBTRIM SPA_TRIM SPB_TRIM DPA_TRIM DPB_TRIM SPMATRIM BPMATRIM 0 0 0 0 0 0 0 0 0 0 0 0 IAQ_ % % % min % % dF SP__ "H2O % % % % sec TRIM 154 ^F ^F ^F ^F ^F ^F PSI PSI PSI PSI APPENDIX B — CCN TABLES (cont) SERVICE-CONFIG TABLES (cont) TABLE SWLG NAME RANGE UNITS POINT NAME DEFAULT Filter Status Inpt-Clean IGC Feedback - Off RemSw Off-Unoc-Strt-NoOv Economizer Switch - No Fan Status Sw. - Off Dmd.Lmt.Sw.1 - Off Dmd.Lmt.-Dehumid - Off IAQ Disc.Input - Low Fire Shutdown - Off Press. Switch - Off Evacuation Sw. - Off Smoke Purge Sw. - Off Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close FLTSLOGC GASFANLG RMTINLOG ECOSWLOG SFSLOGIC DMD_SW1L DMD_SW2L IAQINLOG FSDLOGIC PRESLOGC EVACLOGC PURGLOGC Open Open Open Open Open Open Open Open Open Open Open Open Machine Control Type Fan Mode (0=auto, 1=cont) Remote Switch Config CEM Module installed Temp.Cmp.Strt.Cool Factr Temp.Cmp.Strt.Heat Factr Fan fail shuts down unit Fan Stat Monitoring Type VAV Unocc.Fan Retry time Unit Size (20-60) 20,25,27,30,35,40,50,60 Disch. Press. Transducer Suct. Pres. Trans. Type Refrig: 0=R22 1=R410A Cnd HX Typ:0=RTPF 1=MCHX MAT Calc Config Reset MAT Table Entries? MAT Outside Air Default Altitude……..in feet: Startup Delay Time TSTAT-Both Heat and Cool Auxiliary Relay Config Space Temp Sensor Space Temp Offset Sensor Space Temp Offset Range Return Air RH Sensor Filter Stat.Sw.Enabled ? 1-6 0-1 0 -3 Yes/No 0-60 0-60 Yes/No 0-2 0-720 20-60 CTRLTYPE FAN_MODE RMTINCFG CEM_BRD TCSTCOOL TCSTHEAT SFS_SHUT SFS_MON SAMPMINS UNITSIZE 4 1 0 No 0 0 No 0 50 20 DP_TRANS SPXRTYPE REFRIG_T COILTYPE MAT_SEL MATRESET MATOAPOS ALTITUDE DELAY TSTATALL AUXRELAY SPTSENS SPTOSENS SPTO_RNG RARHSENS FLTS_ENA No 0 POINT_01 Definition POINT_02 Definition POINT_03 Definition POINT_04 Definition POINT_05 Definition POINT_06 Definition POINT_07 Definition POINT_08 Definition POINT_09 Definition POINT_10 Definition POINT_11 Definition POINT_12 Definition POINT_13 Definition POINT_14 Definition POINT_15 Definition POINT_16 Definition POINT_17 Definition POINT_18 Definition POINT_19 Definition POINT_20 Definition 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII 8 CHAR ASCII UNIT Yes/No 0-1 0-1 0-1 0-2 Yes/No 0-100 0-60000 0-900 Yes/No 0-3 Enable/Disable Enable/Disable 1 - 10 Enable/Disable Enable/Disable min min min TONS % sec ^F generics 155 POINT_01 POINT_02 POINT_03 POINT_04 POINT_05 POINT_06 POINT_07 POINT_08 POINT_09 POINT_10 POINT_11 POINT_12 POINT_13 POINT_14 POINT_15 POINT_16 POINT_17 POINT_18 POINT_19 POINT_20 1 No 20 0 0 No 0 Disable Disable 5 Disable Disable APPENDIX B — CCN TABLES (cont) MAINTENANCE DISPLAY TABLES TABLE ALARMS01 DISPLAY NAME RANGE UNITS POINT NAME Active Alarm ------------------------ ascii ascii ALARM_01 Active Alarm ------------------------ ascii ascii ALARM_02 Active Alarm ------------------------ ascii ascii ALARM_03 Active Alarm ------------------------ ascii ascii ALARM_04 Compressor A1 Relay Compressor A1 Feedback Curr.Sens.Brd. A1 Status CSB A1 Feedback Alarm Comp A1 Locked Out ? Compressor A1 Strikes Enable Compressor A1 Compressor A2 Relay Compressor A2 Feedback Curr.Sens.Brd. A2 Status CSB A2 Feedback Alarm Comp A2 Locked Out ? Compressor A2 Strikes Enable Compressor A2 Compressor B1 Relay Compressor B1 Feedback Curr.Sens.Brd. B1 Status CSB B1 Feedback Alarm Comp B1 Locked Out ? Compressor B1 Strikes Enable Compressor B1 Compressor B2 Relay Compressor B2 Feedback Curr.Sens.Brd. B2 Status CSB B2 Feedback Alarm Comp B2 Locked Out ? Compressor B2 Strikes Enable Compressor B2 On/Off On/Off ascii Enable/Disable Yes/No CMPA1 CSB_A1 CSBA1ASC CSB_A1EN CMPA1LOK CMPA1STR CMPA1ENA CMPA2 CSB_A2 CSBA2ASC CSB_A2EN CMPA2LOK CMPA2STR CMPA2ENA CMPB1 CSB_B1 CSBB1ASC CSB_B1EN CMPB1LOK CMPB1STR CMPB1ENA CMPB2 CSB_B2 CSBB2ASC CSB_B2EN CMPB2LOK CMPB2STR CMPB2ENA WRITE STATUS follow same format for… ALARMS02 ALARMS03 ALARMS04 ALARMS05 COMPRESR Enable/Disable On/Off On/Off ascii Enable/Disable Yes/No Enable/Disable On/Off On/Off ascii Enable/Disable Yes/No Enable/Disable On/Off On/Off ascii Enable/Disable Yes/No Enable/Disable config config config config config config config config DMANDLIM Active Demand Limit Percent Total Capacity Demand Limit Select Demand Limit Switch 1 Demand Limit Switch 2 Demand Limit Sw.1 Setpt. Demand Limit Sw.2 Setpt. 4-20 ma Demand Signal Demand Limit at 20 ma CCN Loadshed Signal Loadshed Group Number Loadshed Demand Delta Maximum Loadshed Time 0-100 0-100 0-3 On/Off On/Off 0-100 0-100 4-20 0-100 0-99 0-99 0-60 0-120 156 % % % % ma % % min DEM_LIM CAPTOTAL DMD_CTRL DMD_SW1 DMD_SW2 DLSWSP1 DLSWSP2 DMDLMTMA DMT20MA DL_STAT SHED_NUM SHED_DEL SHED_TIM forcible config forcible forcible config config forcible config config config config APPENDIX B — CCN TABLES (cont) MAINTENANCE DISPLAY TABLES (cont) TABLE ECON_MIN DISPLAY NAME RANGE Econo Damper Command Pos Econo Damper Current Pos Econo Current Min. Pos. Diff.Air Quality in PPM Econo Position Override IAQ Min.Pos.Override Econ Remote 10K Pot Val. IAQ - PPM Return CO2 OAQ - PPM Return CO2 IAQ - Discrete Input IAQ Demand Vent Min.Pos. Economizer Min.Position IAQ Analog Sensor Config IAQ 4-20 ma Fan Config IAQ Discrete Input Confg IAQ Disc.In. Fan Config IAQ Econo Override Pos. Diff.Air Quality LoLimit Diff.Air Quality HiLimit DAQ PPM Fan Off Setpoint DAQ PPM Fan On Setpoint Diff. AQ Responsiveness IAQ Low Reference IAQ High Reference OAQ Lockout Value OAQ 4-20ma Sensor Config IAQ milliamps OAQ milliamps UNITS % % % % % % % ma ma POINT NAME ECONOCMD ECONOPOS ECMINPOS DAQ ECOORIDE IAQMINOV ECON_POT IAQ OAQ IAQIN IAQMINP ECONOMIN IAQANCFG IAQANFAN IAQINCFG IAQINFAN IAQOVPOS DAQ_LOW DAQ_HIGH DAQFNOFF DAQFNON IAQREACT IAQREFL IAQREFH OAQLOCK OAQANCFG IAQ_MA OAQ_MA WRITE STATUS forcible forcible forcible forcible forcible forcible forcible config config config config config config config config config config config config config config config config EC_DIAG Economizer Active ? Conditions which prevent economizer being active: Econ Act. Unavailable? Remote Econ. Disabled ? DBC - OAT lockout? DEW - OA Dewpt. lockout? DDBC- OAT > RAT lockout? OAEC- OA Enth Lockout? DEC - Diff.Enth.Lockout? EDT Sensor Bad ? OAT Sensor Bad ? Economizer forced ? Supply Fan not on 30s ? Cool Mode not in effect? OAQ lockout in effect ? Econ recovery hold off? Outside Air Temperature OutsideAir DewPoint Temp Outside Air Rel.Humidity Outdoor Air Enthalpy Return Air Temperature Return Air Rel.Humidity Return Air Enthalpy High OAT Lockout Temp Econ ChangeOver Select OA Enthalpy ChgOvr Selct Outdr.Enth Compare Value OA Dewpoint Temp Limit Supply Fan State Economizer Act.Cmd.Pos. Economizer Act.Curr.Pos. Evaporator Discharge Tmp Economizer Control Point EDT Trend in degF/minute Economizer Prop.Gain Economizer Range Adjust Economizer Speed Adjust Economizer Deadband Economizer Timer Yes/No ECACTIVE Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No ECONUNAV ECONDISA DBC_STAT DEW_STAT DDBCSTAT OAECSTAT DEC_STAT EDT_STAT OAT_STAT ECONFORC SFONSTAT COOL_OFF OAQLOCKD ECONHELD OAT OADEWTMP OARH OAE RAT RARH RAE OAT_LOCK ECON_SEL OAEC_SEL OAEN_CFG OADEWCFG SFAN ECONOCMD ECONOPOS EDT ECONCPNT EDTTREND EC_PGAIN EC_RANGE EC_SPEED EC_DBAND ERATETMR dF dF % dF % dF dF % % dF dF ^F ^F ^F sec 157 forcible forcible forcible forcible config config config config config forcible config config config config config APPENDIX B — CCN TABLES (cont) MAINTENANCE DISPLAY TABLES (cont) TABLE ENTHALPY DISPLAY NAME RANGE Outdoor Air Enthalpy Outside Air Temperature Outside Air Rel.Humidity Outside Air RH Sensor OA Dewpoint Temp Limit OutsideAir DewPoint Temp OutsideAir Humidty Ratio OA H2O Vapor Sat.Pressur OA H2O Partial.Press.Vap Return Air Enthalpy Return Air Temperature Controlling Return Temp Return Air Rel.Humidity Return Air Temp Sensor Return Air RH Sensor Altitude……..in feet: Atmospheric Pressure UNITS dF % dF dF "Hg "Hg dF dF % "Hg POINT NAME OAE OAT OARH OARHSENS OADEWCFG OADEWTMP OA_HUMR OA_PWS OA_PWS RAE RAT RETURN_T RARH RATSENS RARHSENS ALTITUDE ATMOPRES WRITE STATUS forcible forcible config config forcible forcible forcible config config config config LINKDATA Supervisory Element # Supervisory Bus Supervisory Block Number Average Occup. Heat Stp. Average Occup. Cool Stp. Average Unocc. Heat Stp. Average Unocc. Cool Stp. Average Zone Temperature Average Occup. Zone Temp Linkage System Occupied? Next Occupied Day Next Occupied Time Next Unoccupied Day Next Unoccupied Time Last Unoccupied Day Last Unoccupied Time dF dF dF dF dF dF SUPE-ADR SUPE-BUS BLOCKNUM AOHS AOCS AUHS AUCS AZT AOZT LOCC LNEXTOCD LNEXTOCC LNEXTUOD LNEXTUNC LLASTUOD LLASTUNC MILLIAMP IAQ milliamps OAQ milliamps SP Reset milliamps 4-20 ma Demand Signal EDT Reset milliamps OARH milliamps RARH milliamps BP milliamps SP milliamps ma ma ma ma ma ma ma ma ma IAQ_MA OAQ_MA SPRST_MA DMDLMTMA EDTRESMA OARH_MA RARH_MA BP_MA SP_MA MODES System Mode…………: HVAC Mode…………..: Control Mode………..: Currently Occupied Timed Override in effect DCV resetting min pos Supply Air Reset Demand Limit in Effect Temp.Compensated Start IAQ pre-occ purge active Linkage Active - DAV Mech.Cooling Locked Out HVAC Mode Numerical Form ascii text strings ascii text strings ascii text strings On/Off On/Off On/Off On/Off On/Off On/Off On/Off On/Off On/Off 0-24 Current Day, Time & Date: Occupancy Controlled By: ascii date & time ascii text ascii text ascii text Yes/No MODEOCCP MODETOVR MODEADCV MODESARS MODEDMLT MODETCST MODEIQPG MODELINK MODELOCK MODEHVAC OCCDEFME Currently Occupied Current Occupied Time Current Unoccupied Time Next Occupied Day & Time Next Unocc. Day & Time Last Unocc. Day & Time Current Occup. Period # Timed-Override in Effect Timed-Override Duration Yes/No hours 158 TIMEDATE OCDFTXT1 OCDFTXT2 OCDFTXT3 MODE_OCC STRTTIME ENDTIME NXTOC_DT NXTUN_DT PRVUN_DT PER_NO OVERLAST OVR_HRS forcible APPENDIX B — CCN TABLES (cont) MAINTENANCE DISPLAY TABLES (cont) TABLE PRESBLDG DISPLAY NAME RANGE UNITS Building Pressure Econo Damper Current Pos Power Exhaust Stage A Power Exhaust Stage B Power Exhaust Stage C BP Load Factor BP Rise Per Stage BP PID/Integral Term BP PID Threshold BP Deadband Building Pressure Error Rate of Chng of BPERROR High BP Override Low BP Override "H2O % Static Pressure Supply Fan VFD Speed Static Pressure Setpoint Static Pressure Reset "H2O % "H2O POINT NAME WRITE STATUS BP ECONOPOS PE_A PE_B PE_C BPSMZ BPRISE BPINT BPZ BPY BPERROR BPRATE BPHPOVRD BPLPOVRD config config config config config config config SP SFAN_VFD SPSP SPRESET config forcible PRESDUCT STAGEGAS Heating Mode………..: Requested Heat Stage Heating Control Point Staged Gas LAT Sum Staged Gas LAT 1 Staged Gas LAT 2 Staged Gas LAT 3 Staged Gas Limit Sw.Temp Heat PID Timer Staged Gas Capacity Calc Current Running Capacity Proportional Cap. Change Derivative Cap. Change Maximum Heat Stages Hi Limit Switch Tmp Mode LAT Cutoff Mode Capacity Clamp Mode dF dF dF dF dF sec % % HT_STAGE HEATCPNT LAT_SGAS LAT1SGAS LAT2SGAS LAT3SGAS LIMSWTMP HTSGTIMR HTSGCALC HTSG_CAP HTSG_P HTSG_D HTMAXSTG LIMTMODE LATCMODE CAPMODE STRTHOUR Compressor A1 Run Hours Compressor A2 Run Hours Compressor B1 Run Hours Compressor B2 Run Hours Compressor A1 Starts Compressor A2 Starts Compressor B1 Starts Compressor B2 Starts hours hours hours hours HR_A1 HR_A2 HR_B1 HR_B2 CY_A1 CY_A2 CY_B1 CY_B2 Cooling Control Point Mixed Air Temperature Evaporator Discharge Tmp Return Air Temperature Outside Air Temperature Econo Damper Current Pos Capacity Threshold Adjst Capacity Load Factor Next Stage EDT Decrease Next Stage EDT Increase Rise Per Percent Capacity Cap Deadband Subtracting Cap Deadband Adding Cap Threshold Subtracting Cap Threshold Adding High Temp Cap Override Low Temp Cap Override Pull Down Cap Override Slow Change Cap Override dF dF dF dF dF % On/Off On/Off On/Off On/Off COOLCPNT MAT EDT RAT OAT ECONOPOS Z_GAIN SMZ ADDRISE SUBRISE RISE_PCT Y_MINUS Y_PLUS Z_MINUS Z_PLUS HI_TEMP LOW_TEMP PULLDOWN SLO_CHNG Reset All Current Alarms Reset the Device Local Machine Disable Soft Stop Request Emergency Stop CEM AN1 10K temp J5,1-2 CEM AN2 10K temp J5,3-4 CEM AN3 10K temp J5,5-6 CEM AN4 10K temp J5,7-8 CEM AN1 4-20 ma J5,1-2 CEM AN2 4-20 ma J5,3-4 CEM AN3 4-20 ma J5,5-6 CEM AN4 4-20 ma J5,7-8 Yes/No Yes/No Yes/No Yes/No Enable/Disable -40 - 240 -40 - 240 -40 - 240 -40 - 240 0-20 0-20 0-20 0-20 ALRESET RESETDEV UNITSTOP SOFTSTOP EMSTOP CEM10K1 CEM10K2 CEM10K3 CEM10K4 CEM4201 CEM4202 CEM4203 CEM4204 config config config config config config config config SUMZ SYSTEM 159 dF dF dF dF ma ma ma ma config config config forcible forcible forcible forcible forcible forcible forcible forcible forcible forcible APPENDIX B — CCN TABLES (cont) MAINTENANCE DISPLAY TABLES (cont) TABLE TESTCOOL DISPLAY NAME RANGE Compressor A1 Relay Compressor A2 Relay Min. Load Valve (HGBP) Compressor B1 Relay Compressor B2 Relay ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF Supply Fan Relay Supply Fan VFD Speed Condenser Fan Circuit A Condenser Fan Circuit B ON/OFF 0-100 ON/OFF ON/OFF Requested Heat Stage Heat Relay 1 Heat Relay 2 Relay 3 W1 Gas Valve 2 Relay 4 W2 Gas Valve 2 Relay 5 W1 Gas Valve 3 Relay 6 W2 Gas Valve 3 UNITS POINT NAME WRITE STATUS CMPA1TST CMPA2TST MLV_TST CMPB1TST CMPB2TST test test test test test SFAN_TST SGVFDTST CNDA_TST CNDB_TST test test test test 0-MAX ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF HTST_TST HS1_TST HS2_TST HS3_TST HS4_TST HS5_TST HS6_TST test test test test test test test Economizer Position Test Economizer Power Test Calibrate the Economizer? Power Exhaust Relay A Power Exhaust Relay B Power Exhaust Relay C Heat Interlock Relay Remote Alarm/Aux Relay ON/OFF ON/OFF ECONCTST ECONPTST ECON_CAL PE_A_TST PE_B_TST PE_C_TST HIR_TST ALRM_TST test test test test test test test test MBB CESR131343ECB1 CESR131249ECB2 CESR131249SCB CESR131226CEM CESR131174MARQUEE CESR131171NAVIGATOR CESR130227- ascii version# ascii version# ascii version# ascii version# ascii version# ascii version# ascii version# MBB_SW ECB1_SW ECB2_SW SCB_SW CEM_SW MARQ_SW NAVI_SW TESTFANS % TESTHEAT TESTINDP VERSIONS TIME SCHEDULE CONFIG TABLE Allowable Entries: Day not selected = 0 Day selected = 1 Period 1: Period 2: Period 3: Period 4: Period 5: Period 6: Period 7: Period 8: DAY FLAGS MTWTFSSH OCCUPIED TIME UNOCCUPIED TIME 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00:00 00:00 00:00 00:00 00:00 00:00 00:00 00:00 00:00 00:00 00:00 00:00 00:00 00:00 00:00 00:00 160 APPENDIX C — VFD INFORMATION condensation from forming on the boards during the off mode and is stopped by driving the speed to 0 (by sending a 4 mA signal to the VFD). The A Series units use ABB VFDs. The interface wiring for the VFDs is shown in Fig. A. The VFD connects through an isolation board to the 4 to 20 mA RCB board. Terminal designations are shown in Table A. Configurations are shown in Table B. On variable air volume units with optional VFD, the supply fan speed is controlled by a 3-phase VFD. The VFD is located in the supply fan section behind a removable panel. The VFD speed is controlled directly by the ComfortLink™ controls through a 4 to 20 mA signal based on a supply duct pressure sensor. The VFD has a display, which can be used for service diagnostics, but setup of the building pressure and control loop factors should be done through the scrolling marquee display. The VFD is powered during normal operation to prevent Table A — VFD Terminal Designations TERMINAL U1 V1 W1 U2 V2 W2 X1-11 (GND) X1-12 (COMMON) X1-10 (24 VDC) X1-13 (DI-1) X1-10 (24 VDC) X1-16 (DI-4) X1-2 (AI-1) X1-3 (AGND) FUNCTION Three-Phase Main Circuit Input Power Supply Three-Phase AC Output to Motor, 0 V to Maximum Input Voltage Level Factory-supplied jumper Run (factory-supplied jumper) Start Enable 1 (Factory-supplied jumper). When opened the drive goes to emergency stop. Factory wired for 4 to 20 mA remote input A48-7712 Fig. A — VFD Wiring 161 APPENDIX C — VFD INFORMATION (cont) Table B — VFD Configurations PARAMETER GROUP Start-Up Data Start/Stop/Dir Analog Inputs Relay Outputs System Controls OVER RIDE Accel/Decel MOTOR PARAMETER TITLE LANGUAGE APPLIC MACRO MOTOR CTRL MODE MOTOR NOM VOLT MOTOR NOM CURR MOTOR NOM FREQ MOTOR NOM SPEED EXT1 COMMANDS DIRECTION MINIMUM AI1 MAXIMUM AI1 RELAY OUTPUT 1 RELAY OUTPUT 2 RELAY OUTPUT 3 RUN ENABLE START ENABLE 1 OVERRIDE SEL OVERRIDE FREQ OVERRIDE SPEED OVER PASS CODE OVERRIDE STOP FUNCTION ACCELER TIME 1 DECELER TIME 1 SWITCHING FREQ PARAMETER INDEX 9901 9902 9904 9905 9906 9907 9908 1001 1003 1301 1302 1401 1402 1403 1601 1608 1701 1702 1703 1704 1705 2102 2202 2203 2606 VFD Operation — The VFD keypad is shown in Fig. B. The function of SOFT KEYS 1 and 2 change depending on what is displayed on the screen. The function of SOFT KEY 1 matches the word in the lower left-hand box on the display screen. The function of SOFT KEY 2 matches the word in the lower right-hand box on the display screen. If the box is empty, then the SOFT KEY does not have a function on that specific screen. The UP and DOWN keys are used to navigate through the menus. The OFF key is used to turn off the VFD. The AUTO key is used to change control of the drive to automatic control. The HAND key is used to change control of the drive to local (hand held) control. The HELP button is used to access the help screens. CARRIER DEFAULT ENGLISH USER 1 SCALAR: FREQ 460v *TBD* 60 Hz 1750 rpm DI-1 REVERSE 20.0 % 100.0 % STARTED RUN FAULT (-1) NOT SELECTED DI-4 DI-3 60 Hz 1750 rpm ENTERED ON RAMP 30.0s 30.0s 8 kHz START UP WITH ASSISTANT — Initial start-up has been performed at the factory. To start up the VFD with the Start-Up Assistant or reset the VFD with the Carrier defaults, perform the following procedure: 1. Select MENU (SOFT KEY 2). The Main menu will be displayed. 2. Use the UP or DOWN keys to highlight ASSISTANTS on the display screen and press ENTER (SOFT KEY 2). 3. Use the UP or DOWN keys to highlight Carrier Assistant and press SEL (SOFT KEY 2). 4. The Carrier Assistant will ask questions to determine the correct parameters for the VFD. Select the desired values and press SAVE (SOFT KEY 2) after every change. The process will continue until all the parameters are set. a. The Carrier Assistant will ask “Is this an Air Handler or Rooftop?” Select “Rooftop.” b. The Carrier Assistant will ask “Is this a High E or Premium E motor?” Select the correct efficiency type. c. If the VFD can be used with two different size (HP) motors, then the Carrier Assistant will ask the user to choose the proper HP. Select the correct motor horsepower. START UP BY CHANGING PARAMETERS INDIVIDUALLY — Initial start-up is performed at the factory. To start up the VFD with by changing individual parameters, perform the following procedure: 1. Select MENU (SOFT KEY 2). The Main menu will be displayed. 2. Use the UP or DOWN keys to highlight PARAMETERS on the display screen and press ENTER (SOFT KEY 2). 3. Use the UP or DOWN keys to highlight the desired parameter group and press SEL (SOFT KEY 2). A39-2918 Fig. B — VFD Keypad 162 APPENDIX C — VFD INFORMATION (cont) 4. Use the UP or DOWN keys to highlight the desired parameter and press EDIT (SOFT KEY 2). 5. Use the UP or DOWN keys to change the value of the parameter. 6. Press SAVE (SOFT KEY 2) to store the modified value. Press CANCEL (SOFT KEY 1) to keep the previous value. Any modifications that are not saved will not be changed. 7. Choose another parameter or press EXIT (SOFT KEY 1) to return to the listing of parameter groups. Continue until all the parameters have been configured and then press EXIT (SOFT KEY 1) to return to the main menu. NOTE: The current parameter value appears above the highlight parameter. To view the default parameter value, press the UP and DOWN keys simultaneously. To restore the default factory settings, select the application macro “HVAC Default.” A48-7713 Fig. C — Standard Display Example To adjust the speed in HAND mode, press the UP or DOWN buttons (the reference changes immediately). The reference can be modified in the local control (HAND) mode, and can be parameterized (using Group 11 reference select) to also allow modification in the remote control mode. PARAMETERS MODE — The Parameters mode is used to change the parameters on the drive. To change parameters, perform the following procedure: 1. Select MENU (SOFT KEY 2). The Main menu will be displayed. 2. Use the UP or DOWN keys to highlight PARAMETERS on the display screen and press ENTER (SOFT KEY 2). 3. Use the UP or DOWN keys to highlight the desired parameter group and press SEL (SOFT KEY 2). 4. Use the UP or DOWN keys to highlight the desired parameter and press EDIT (SOFT KEY 2). 5. Use the UP or DOWN keys to change the value of the parameter. 6. Press SAVE (SOFT KEY 2) to store the modified value. Press CANCEL (SOFT KEY 1) to keep the previous value. Any modifications that are not saved will not be changed. 7. Choose another parameter or press EXIT (SOFT KEY 1) to return to the listing of parameter groups. Continue until all the parameters have been configured and then press EXIT (SOFT KEY 1) to return to the main menu. NOTE: The current parameter value appears above the highlight parameter. To view the default parameter value, press the UP and DOWN keys simultaneously. To restore the default factory settings, select the Carrier application macro. START-UP ASSISTANT MODE — To use the Start-Up Assistant, perform the following procedure: 1. Select MENU (SOFT KEY 2). The Main menu will be displayed. 2. Use the UP or DOWN keys to highlight ASSISTANTS on the display screen and press ENTER (SOFT KEY 2). 3. Use the UP or DOWN keys to highlight Commission Drive and press SEL (SOFT KEY 2). 4. The Start-Up Assistant will display the parameters that need to be configured. Select the desired values and press SAVE (SOFT KEY 2) after every change. The process will continue until all the parameters are set. The assistant checks to make sure that entered values are in range. The assistant is divided into separate tasks. The user can activate the tasks one after the other or independently. The tasks are typically done in this order: Application, References 1 and 2, Start/Stop Control, Protections, Constant Speeds, PID Control, Low Noise Setup, Panel Display, Timed Functions, and Outputs. VFD Modes — The VFD has several different modes for configuring, operating, and diagnosing the VFD. The modes are: • Standard Display mode — shows drive status information and operates the drive • Parameters mode — edits parameter values individually • Start-up Assistant mode — guides the start-up and configuration • Changed Parameters mode — shows all changed parameters • Drive Parameter Backup mode — stores or uploads the parameters • Clock Set mode — sets the time and date for the drive • I/O Settings mode — checks and edits the I/O settings STANDARD DISPLAY MODE — Use the standard display mode to read information on the drive status and operate the drive. To reach the standard display mode, press EXIT until the LCD display shows status information as described below. See Fig. C. The top line of the LCD display shows the basic status information of the drive. The HAND icon indicates that the drive control is local from the control panel. The AUTO icon indicates that the drive is in remote control mode, such as the basic I/O (X1) or field bus. The arrow icon indicates the drive and motor rotation status. A rotating arrow (clockwise or counterclockwise) indicates that the drive is running and at set point and the shaft direction is forward or reverse. A rotating blinking arrow indicates that the drive is running but not at set point. A stationary arrow indicates that the drive is stopped. For Carrier rooftop units, the correct rotation is counterclockwise. The upper right corner shows the frequency set point that the drive will maintain. Using parameter group 34, the middle of the LCD display can be configured to display 3 parameter values. The default display shows parameters 0103 (OUTPUT FREQ) in percentages, 0104 (CURRENT) in amperes, and 0120 (AI1) in milliamperes. The bottom corners of the LCD display show the functions currently assigned to the two soft keys. The lower middle displays the current time (if configured to show the time). The first time the drive is powered up, it is in the OFF mode. To switch to local hand-held control and control the drive using the control panel, press and hold the HAND button. Pressing the HAND button switches the drive to hand control while keeping the drive running. Press the AUTO button to switch to remote input control. To start the drive press the HAND or AUTO buttons, to stop the drive press the OFF button. 163 APPENDIX C — VFD INFORMATION (cont) 5. The text “Restoring Parameters” will be displayed with a progress indicator. To stop the process, select ABORT (SOFT KEY 1). 6. When the download is complete, the text “Parameter download successful” will be displayed. 7. The display will then return to the PAR BACKUP menu. Select EXIT (SOFT KEY 1) to return to the main menu. 8. The control panel can now be disconnected from the drive. Download Application Parameters — To download application parameters only to the control panel from the VFD, perform the following procedure: 1. Install the control panel with the correct parameters onto the VFD. 2. Select MENU (SOFT KEY 2). The Main menu will be displayed. 3. Use the UP or DOWN keys to highlight PAR BACKUP on the display screen and press ENTER (SOFT KEY 2). 4. Use the UP or DOWN keys to highlight DOWNLOAD APPLICATION and press SEL (SOFT KEY 2). 5. The text “Downloading Parameters (partial)” will be displayed with a progress indicator. To stop the process, select ABORT (SOFT KEY 1). 6. When the download is complete, the text “Parameter download successful” will be displayed. 7. The display will then return to the PAR BACKUP menu. Select EXIT (SOFT KEY 1) to return to the main menu. 8. The control panel can now be disconnected from the drive. CLOCK SET MODE — The clock set mode is used for setting the date and time for the internal clock of the VFD. In order to use the timer functions of the VFD control, the internal clock must be set. The date is used to determine weekdays and is visible in the fault logs. To set the clock, perform the following procedure: 1. Select MENU (SOFT KEY 2). The Main menu will be displayed. 2. Use the UP or DOWN keys to highlight CLOCK SET on the display screen and press ENTER (SOFT KEY 2). The clock set parameter list will be displayed. 3. Use the UP or DOWN keys to highlight CLOCK VISIBILITY and press SEL (SOFT KEY 2). This parameter is used to display or hide the clock on the screen. Use the UP or DOWN keys to change the parameter setting. Press OK (SOFT KEY 2) to save the configuration and return to the Clock Set menu. 4. Use the UP or DOWN keys to highlight SET TIME and press SEL (SOFT KEY 2). Use the UP or DOWN keys to change the hours and minutes. Press OK (SOFT KEY 2) to save the configuration and return to the Clock Set menu. 5. Use the UP or DOWN keys to highlight TIME FORMAT and press SEL (SOFT KEY 2). Use the UP or DOWN keys to change the parameter setting. Press OK (SOFT KEY 2) to save the configuration and return to the Clock Set menu. 6. Use the UP or DOWN keys to highlight SET DATE and press SEL (SOFT KEY 2). Use the UP or DOWN keys to change the day, month, and year. Press OK (SOFT KEY 2) to save the configuration and return to the Clock Set menu. CHANGED PARAMETERS MODE — The Changed Parameters mode is used to view and edit recently changed parameters on the drive. To view the changed parameters, perform the following procedure: 1. Select MENU (SOFT KEY 2). The Main menu will be displayed. 2. Use the UP or DOWN keys to highlight CHANGED PAR on the display screen and press ENTER (SOFT KEY 2). A list of the recently changed parameters will be displayed. 3. Use the UP or DOWN keys to highlight the desired parameter group and press EDIT (SOFT KEY 2) to change the parameter if desired. 4. Press EXIT (SOFT KEY 1) to exit the Changed Parameters mode. DRIVE PARAMETER BACKUP MODE — The drive parameter back up mode is used to export the parameters from one drive to another. The parameters can be uploaded from a VFD to the removable control panel. The control panel can then be transferred to another drive and the parameters downloaded into memory. Depending on the motor and application, there are two options available. The first option is to download all parameters. This copies both application and motor parameters to the drive from the control panel. This is recommended when using the same application for drives of the same size. This can also be used to create a backup of the parameters group for the drive. The second option downloads only the application parameters to the drive. This is recommended when using the same application for drives of different sizes. Parameters 9905, 9906, 9907, 9908, 9909, 1605, 1607, 5201, and group 51 parameters and internal motor parameters are not copied. Upload All Parameters — To upload and store parameters in the control panel from the VFD, perform the following procedure: 1. Select MENU (SOFT KEY 2). The Main menu will be displayed. 2. Use the UP or DOWN keys to highlight PAR BACKUP on the display screen and press ENTER (SOFT KEY 2). 3. Use the UP or DOWN keys to highlight UPLOAD TO PANEL and press SEL (SOFT KEY 2). 4. The text “Copying Parameters” will be displayed with a progress indicator. To stop the process, select ABORT (SOFT KEY 1). 5. When the upload is complete, the text “Parameter upload successful” will be displayed. 6. The display will then return to the PAR BACKUP menu. Select EXIT (SOFT KEY 1) to return to the main menu. 7. The control panel can now be disconnected from the drive. Download All Parameters — To download all parameters from the control panel to the VFD, perform the following procedure: 1. Install the control panel with the correct parameters onto the VFD. 2. Select MENU (SOFT KEY 2). The Main menu will be displayed. 3. Use the UP or DOWN keys to highlight PAR BACKUP on the display screen and press ENTER (SOFT KEY 2). 4. Use the UP or DOWN keys to highlight DOWNLOAD TO DRIVE ALL and press SEL (SOFT KEY 2). 164 APPENDIX C — VFD INFORMATION (cont) The fault code on the control panel display is temporary. Pressing the MENU, ENTER, UP button or DOWN buttons removes the fault message. The message reappears after a few seconds if the control panel is not touched and the fault is still active. ALARMS (GREEN LED FLASHING) — For less severe errors, called alarms, the diagnostic display is advisory. For these situations, the drive is simply reporting that it had detected something unusual. In these situations, the drive: • flashes the green LED on the drive (does not apply to alarms that arise from control panel operation errors) • sets an appropriate bit in an Alarm Word parameter (0308 or 0309) • overrides the control panel display with the display of an alarm code and/or name Alarm messages disappear from the control panel display after a few seconds. The message returns periodically as long as the alarm condition exists. CORRECTING FAULTS — The recommended corrective action for faults is shown in the Fault Listing Table C. The VFD can also be reset to remove the fault. If an external source for a start command is selected and is active, the VFD may start immediately after fault reset. To reset a fault indicated by a flashing red LED, turn off the power for 5 minutes. To reset a fault indicated by a red LED (not flashing), press RESET from the control panel or turn off the power for 5 minutes. Depending on the value of parameter 1604 (FAULT RESET SELECT), digital input or serial communication could also be used to reset the drive. When the fault has been corrected, the motor can be started. HISTORY — For reference, the last three fault codes are stored into parameters 0401, 0412, 0413. For the most recent fault (identified by parameter 0401), the drive stores additional data (in parameters 0402 through 0411) to aid in troubleshooting a problem. For example, a parameter 0404 stores the motor speed at the time of the fault. To clear the fault history (all of Group 04, Fault History parameters), follow these steps: 1. In the control panel, Parameters mode, select parameter 0401. 2. Press EDIT. 3. Press the UP and DOWN buttons simultaneously. 4. Press SAVE. CORRECTING ALARMS — To correct alarms, first determine if the Alarm requires any corrective action (action is not always required). Use Table D to find and address the root cause of the problem. If diagnostics troubleshooting has determined that the drive is defective during the warranty period, contact ABB Automation Inc., at 1-800-435-7365, option 4, option 3. A qualified technician will review the problem with the caller and make a determination regarding how to proceed. This may involve dispatching a designated service station (DSS) representative from an authorized station, dispatching a replacement unit, or advising return for repair. 7. Use the UP or DOWN keys to highlight DATE FORMAT and press SEL (SOFT KEY 2). Use the UP or DOWN keys to change the parameter setting. Press OK (SOFT KEY 2) to save the configuration and return to the Clock Set menu. 8. Press EXIT (SOFT KEY 1) twice to return to the main menu. I/O SETTINGS MODE — The I/O Settings mode is used for viewing and editing the I/O settings. To configure the I/O settings, perform the following procedure: 1. Select MENU (SOFT KEY 2). The Main menu will be displayed. 2. Use the UP or DOWN keys to highlight I/O SETTINGS on the display screen and press ENTER (SOFT KEY 2). The I/O Settings parameter list will be displayed. 3. Use the UP or DOWN keys to highlight the desired I/O setting and press SEL (SOFT KEY 2). 4. Use the UP or DOWN keys to select the parameter to view. Press OK (SOFT KEY 2). 5. Use the UP or DOWN keys to change the parameter setting. Press SAVE (SOFT KEY 2) to save the configuration. Press CANCEL (SOFT KEY 1) to keep the previous value. Any modifications that are not saved will not be changed. 6. Press EXIT (SOFT KEY 1) twice to return to the main menu. Third Party Controls — For conversion to third party control of the VFD, perform the following procedure: 1. Remove the factory-installed jumper between X1-10 and X1-13 (control of VFD start/stop). 2. Remove the factory-installed jumper between X1-10 and X1-16 and replace with a normally closed safety contact for control of VFD start enable. 3. Install speed signal wires to AI-1 and AGND. This input is set at the factory for a 4 to 20 mA signal. If a 0 to 10 vdc signal is required, change DIP switch J1 (located above the VFD control terminal strip) to OFF (right position to left position) and change parameter 1301 to 0% from 20%. VFD Diagnostics — The drive detects error situations and reports them using: • the green and red LEDs on the body of the drive (located under the keypad) • the status LED on the control panel • the control panel display • the Fault Word and Alarm Word parameter bits (parameters 0305 to 0309) The form of the display depends on the severity of the error. The user can specify the severity for many errors by directing the drive to ignore the error situation, report the situation as an alarm, or report the situation as a fault. FAULTS (RED LED LIT) — The VFD signals that it has detected a severe error, or fault, by: • enabling the red LED on the drive (LED is either steady or flashing) • setting an appropriate bit in a Fault Word parameter (0305 to 0307) • overriding the control panel display with the display of a fault code • stopping the motor (if it was on) VFD Maintenance — If installed in an appropriate envi- ronment, the VFD requires very little maintenance. Table E lists the routine maintenance intervals recommended by Carrier. HEAT SINK — The heat sink fins accumulate dust from the cooling air. Since a dusty sink is less efficient at cooling the drive, overtemperature faults become more likely. In a normal environment check the heat sink annually, in a dusty environment check more often. 165 APPENDIX C — VFD INFORMATION (cont) Table C — Fault Codes FAULT CODE FAULT NAME IN PANEL 1 OVERCURRENT 2 DC OVERVOLT 3 DEV OVERTEMP 4 5 SHORT CIRC OVERLOAD 6 DC UNDERVOLT 7 AI1 LOSS 8 AI2 LOSS 9 MOT OVERTEMP 10 PANEL LOSS 11 ID RUN FAIL 12 MOTOR STALL 13 14 15 RESERVED EXT FAULT 1 EXT FAULT 2 16 EARTH FAULT 17 UNDERLOAD 18 19 20 21 22 23 THERM FAIL OPEX LINK OPEX PWR CURR MEAS SUPPLY PHASE RESERVED 24 OVERSPEED 25 26 27 RESERVED DRIVE ID CONFIG FILE 28 SERIAL 1 ERR 29 30 31 32 33 34 35 101-105 201-206 EFB CON FILE FORCE TRIP EFB 1 EFB 2 EFB 3 MOTOR PHASE OUTP WIRING SYSTEM ERROR SYSTEM ERROR 1000 PAR HZRPM 1001 PAR PFA REFNG 1002 PAR PFA IOCNF 1003 PAR AI SCALE 1004 PAR AO SCALE 1005 PAR PCU 2 1006 PAR EXT RO 1007 PAR FBUS 1008 PAR PFA MODE 1009 PAR PCU 1 1010 OVERRIDE/PFA CONFLICT DESCRIPTION AND RECOMMENDED CORRECTIVE ACTION Output current is excessive. Check for excessive motor load, insufficient acceleration time (parameters 2202 ACCELER TIME 1, default 30 seconds), or faulty motor, motor cables or connections. Intermediate circuit DC voltage is excessive. Check for static or transient over voltages in the input power supply, insufficient deceleration time (parameters 2203 DECELER TIME 1, default 30 seconds), or undersized brake chopper (if present). Drive heat sink is overheated. Temperature is at or above 115 C (239 F). Check for fan failure, obstructions in the air flow, dirt or dust coating on the heat sink, excessive ambient temperature, or excessive motor load. Fault current. Check for short-circuit in the motor cable(s) or motor or supply disturbances. Inverter overload condition. The drive output current exceeds the ratings. Intermediate circuit DC voltage is not sufficient. Check for missing phase in the input power supply, blown fuse, or under voltage on main circuit. Analog input 1 loss. Analog input value is less than AI1 FLT LIMIT (3021). Check source and connection for analog input and parameter settings for AI1 FLT LIMIT (3021) and 3001 AI2002 MAXIMUM SPEED 2007 MINIMUM FREQ > 2008 MAXIMUM FREQ 2001 MINIMUM SPEED / 9908 MOTOR NOM SPEED is outside of the range: -128/+128 2002 MAXIMUM SPEED / 9908 MOTOR NOM SPEED is outside of the range: -128/+128 2007 MINIMUM FREQ / 9907 MOTOR NOM FREQ is outside of the range: - 128/+128 2008 MAXIMUM FREQ / 9907 MOTOR NOM FREQ is outside of the range: - 128/+128 Parameter values are inconsistent. Check that 2007 MINIMUM FREQ is negative, when 8123 PFA ENABLE is active. Parameter values are inconsistent. The number of programmed PFA relays does not match with Interlock configuration, when 8123 PFA ENABLE is active. Check consistency of RELAY OUTPUT parameters 1401 through 1403, and 1410 through 1412. Check 8117 NR OF AUX MOTORS, 8118 AUTOCHANGE INTERV, and 8120 INTERLOCKS. Parameter values are inconsistent. Check that parameter 1301 AI 1 MIN > 1302 AI 1 MAX and that parameter 1304 AI 2 MIN > 1305 AI 2 MAX. Parameter values are inconsistent. Check that parameter 1504 AO 1 MIN > 1505 AO 1 MAX and that parameter 1510 AO 2 MIN > 1511 AO 2 MAX. Parameter values for power control are inconsistent: Improper motor nominal kVA or motor nominal power. Check the following parameters: 1.1 < (9906 MOTOR NOM CURR * 9905 MOTOR NOM VOLT * 1.73 / PN) < 2.6 Where: PN = 1000 * 9909 MOTOR NOM POWER (if units are kW) or PN = 746 * 9909 MOTOR NOM POWER (if units are HP, e.g., in US) Parameter values are inconsistent. Check the extension relay module for connection and 1410 through 1412 RELAY OUTPUTS 4 through 6 have non-zero values. Parameter values are inconsistent. Check that a parameter is set for field bus control (e.g., 1001 EXT1 COMMANDS = 10 (COMM)), but 9802 COMM PROT SEL = 0. Parameter values are inconsistent. The 9904 MOTOR CTRL MODE must = 3 (SCALAR SPEED) when 8123 PFA ENABLE activated. Parameter values for power control are inconsistent or improper motor nominal frequency or speed. Check for both of the following: 1 < (60 * 9907 MOTOR NOM FREQ / 9908 MOTOR NOM SPEED < 16 0.8 < 9908 MOTOR NOM SPEED / (120 * 9907 MOTOR NOM FREQ / Motor poles) < 0.992 Override mode is enabled and PFA is activated at the same time. This cannot be done because PFA interlocks cannot be observed in the override mode. 166 APPENDIX C — VFD INFORMATION (cont) Table D — Alarm Codes ALARM CODE ALARM NAME IN PANEL 2001 — Reserved 2002 — Reserved 2003 — Reserved 2004 DIR LOCK 2005 I/O COMM 2006 AI1 LOSS 2007 AI2 LOSS 2008 PANEL LOSS 2009 — 2010 MOT OVERTEMP 2011 UNDERLOAD 2012 MOTOR STALL 2013* AUTORESET 2014* AUTOCHANGE 2015 PFA INTERLOCK 2016 2017* — OFF BUTTON 2018* PID SLEEP 2019 2020 ID RUN OVERRIDE START ENABLE 1 MISSING START ENABLE 2 MISSING EMERGENCY STOP 2021 2022 2023 DESCRIPTION AND RECOMMENDED CORRECTIVE ACTION The change in direction being attempted is not allowed. Do not attempt to change the direction of motor rotation, or Change parameter 1003 DIRECTION to allow direction change (if reverse operation is safe). Field bus communication has timed out. Check fault setup (3018 COMM FAULT FUNC and 3019 COMM FAULT TIME). Check communication settings (Group 51 or 53 as appropriate). Check for poor connections and/or noise on line. Analog input 1 is lost, or value is less than the minimum setting. Check input source and connections. Check the parameter that sets the minimum (3021) and the parameter that sets the Alarm/Fault operation (3001). Analog input 2 is lost, or value is less than the minimum setting. Check input source and connections. Check parameter that sets the minimum (3022) and the parameter that sets the Alarm/Fault operation (3001). Panel communication is lost and either the VFD is in local control mode (the control panel displays HAND), or the VFD is in remote control mode (AUTO) and is parameterized to accept start/stop, direction or reference from the control panel. To correct, check the communication lines and connections, Parameter 3002 PANEL LOSS, and parameters in groups 10 COMMAND INPUTS and 11 REFERENCE SELECT (if drive operation is REM). Reserved Motor is hot, based on either the VFD estimate or on temperature feedback. This alarm warns that a Motor Overload fault trip may be near. Check for overloaded motor. Adjust the parameters used for the estimate (3005 through 3009). Check the temperature sensors and Group 35 parameters. Motor load is lower than expected. This alarm warns that a Motor Underload fault trip may be near. Check that the motor and drive ratings match (motor is NOT undersized for the drive). Check the settings on parameters 3013 to 3015. Motor is operating in the stall region. This alarm warns that a Motor Stall fault trip may be near. This alarm warns that the drive is about to perform an automatic fault reset, which may start the motor. To control automatic reset, use parameter group 31 (AUTOMATIC RESET). This alarm warns that the PFA autochange function is active. To control PFA, use parameter group 81 (PFA) and the Pump Alternation macro. This alarm warns that the PFA interlocks are active, which means that the drive cannot start any motor (when Autochange is used), or a speed regulated motor (when Autochange is not used). Reserved This alarm indicates that the OFF button has been pressed. This alarm warns that the PID sleep function is active, which means that the motor could accelerate when the PID sleep function ends. To control PID sleep, use parameters 4022 through 4026 or 4122 through 4126. The VFD is performing an ID run. Override mode is activated. This alarm warns that the Start Enable 1 signal is missing. To control Start Enable 1 function, use parameter 1608. To correct, check the digital input configuration and the communication settings. This alarm warns that the Start Enable 2 signal is missing. To control Start Enable 2 function, use parameter 1609. To correct, check the digital input configuration and the communication settings. Emergency stop is activated. *This alarm is not indicated by a relay output, even when the relay output is configured to indicate alarm conditions, parameter 1401 RELAY OUTPUT = 5 (ALARM) or 16 (FLT/ALARM). Check the heat sink as follows (when necessary): 1. Remove power from drive. 2. Remove the cooling fan. 3. Blow clean compressed air (not humid) from bottom to top and simultaneously use a vacuum cleaner at the air outlet to trap the dust. If there a risk of the dust entering adjoining equipment, perform the cleaning in another room. 4. Replace the cooling fan. 5. Restore power. Table E — Maintenance Intervals 167 MAINTENANCE INTERVAL Heat Sink Temperature Check and Cleaning Main Cooling Fan Replacement Internal Enclosure Cooling Fan Replacement Capacitor Change (Frame Size R5 and R6) HVAC Control Panel Battery Change Every 6 to 12 months (depending on the dustiness of the environment) Every five years Every three years Every ten years Every ten years APPENDIX C — VFD INFORMATION (cont) MAIN FAN REPLACEMENT — The main cooling fan of the VFD has a life span of about 60,000 operating hours at maximum rated operating temperature and drive load. The expected life span doubles for each 18 F drop in the fan temperature (fan temperature is a function of ambient temperatures and drive loads). Fan failure can be predicted by the increasing noise from fan bearings and the gradual rise in the heat sink temperature in spite of heat sink cleaning. If the drive is operated in a critical part of a process, fan replacement is recommended once these symptoms start appearing. Replacement fans are available from Carrier. To replace the main fan for frame sizes R1 through R4, perform the following (see Fig. D): 1. Remove power from drive. 2. Remove drive cover. 3. For frame sizes R1 and R2, press together the retaining clips on the fan cover and lift. For frame sizes R3 and R4, press in on the lever located on the left side of the fan mount, and rotate the fan up and out. 4. Disconnect the fan cable. 5. Install the new fan by reversing Steps 2 to 4. 6. Restore power. To replace the main fan for frame sizes R5 and R6, perform the following (see Fig. E): 1. Remove power from drive. 2. Remove the screws attaching the fan. 3. Disconnect the fan cable. 4. Install the fan in reverse order. 5. Restore power. INTERNAL ENCLOSURE FAN REPLACEMENT — The VFD IP 54 / UL Type 12 enclosures have an additional internal fan to circulate air inside the enclosure. To replace the internal enclosure fan for frame sizes R1 to R4, perform the following (see Fig. F): 1. Remove power from drive. 2. Remove the front cover. 3. The housing that holds the fan in place has barbed retaining clips at each corner. Press all four clips toward the center to release the barbs. 4. When the clips/barbs are free, pull the housing up to remove from the drive. 5. Disconnect the fan cable. 6. Install the fan in reverse order, noting the following: the fan airflow is up (refer to arrow on fan); the fan wire harness is toward the front; the notched housing barb is located in the right-rear corner; and the fan cable connects just forward of the fan at the top of the drive. To replace the internal enclosure fan for frame sizes R5 or R6, perform the following: 1. Remove power from drive. 2. Remove the front cover. 3. Lift the fan out and disconnect the cable. 4. Install the fan in reverse order. 5. Restore power. 3 3 4 2 A39-2922 Fig. D — Main Fan Replacement (Frame Sizes R1-R4) Bottom View (R5) 3 2 A48-7714 Bottom View (R6) 3 2 A48-7715 Fig. E — Main Fan Replacement (Frame Sizes R5 and R6) CONTROL PANEL CLEANING — Use a soft damp cloth to clean the control panel. Avoid harsh cleaners which could scratch the display window. BATTERY REPLACEMENT — A battery is only used in assistant control panels that have the clock function available and enabled. The battery keeps the clock operating in memory during power interruptions. The expected life for the battery is greater than ten years. To remove the battery, use a coin to rotate the battery holder on the back of the control panel. Replace the battery with type CR2032. 168 APPENDIX C — VFD INFORMATION (cont) A48-7716 Fig. F — Internal Enclosure Fan Replacement 169 APPENDIX D — MODE SELECTION PROCESS { HVAC mode: ("Off ") — The unit is off and no operating modes are active. HVAC mode: ("Tempering Vent ") — The economizer is at minimum vent position but the supply air temperature has dropped below the tempering vent set point. Gas heat is used to temper the ventilation air. HVAC mode: ("Tempering LoCool") — The economizer is at minimum vent position but the combination of the outside-air temperature and the economizer position has dropped the supply-air temperature below the tempering cool set point. Gas heat is used to temper the ventilation air. HVAC mode: ("Tempering HiCool") — The economizer is at minimum vent position but the combination of the outside air temperature and the economizer position has dropped the supply air temperature below the tempering cool set point. Gas heat is used to temper the ventilation air. HVAC mode: (“Re-Heat”) — The unit is operating in reheat mode. HVAC mode: (“Dehumidification”) — The unit is operating in dehumidification mode. HVAC mode: ("Vent ") — This is a normal operation mode where no heating or cooling is required and outside air is being delivered to the space to control IAQ levels. HVAC mode: ("Low Cool ") — This is a normal cooling mode when a low cooling demand exists. HVAC mode: ("High Cool ") — This is a normal cooling mode when a high cooling demand exists. HVAC mode: ("Low Heat ") — This is a normal heating mode when a low heating demand exists. HVAC mode: ("High Heat ") — This is a normal heating mode when a high heating demand exists. HVAC mode: ("Unocc. Free Cool") — In this mode the unit will operate in cooling but will be using the economizer for free cooling. Entering this mode will depend on the status of the outside air. The unit can be configured for outside air changeover, differential dry bulb changeover, outside air enthalpy changeover, differential enthalpy changeover, or a custom arrangement of enthalpy/dewpoint and dry bulb. See the Economizer section for further details.} NOTE: There is also a transitional mode whereby the machine may be waiting for relay timeguards to expire before shutting the machine completely down: HVAC mode: ("Shutting Down ") The following section is to be used in conjunction with Fig. 4 on page 34. To help determine why the unit controls are in a certain mode, the programming logic is provided below. The software will proceed, step by step, until a mode is reached. If an “If” statement is true, then that mode will be entered. The “Else” statement refers to other possible choices. If the System Mode is OFF: { If the fire shut down input (InputsFIREFSD) is in “alarm”: HVAC mode: ("Fire Shut Down ") OFF Else HVAC mode: ("Disabled ") OFF} Else If: The rooftop is not in “factory test” and a fire smoke-control mode is “alarming”: { If the pressurization input (InputsFIREPRES) is in “alarm”: HVAC mode: ("Pressurization ") Else If the evacuation input (InputsFIREEVAC) is in “alarm”: HVAC mode: ("Evacuation ") Else If the smoke purge input (InputsFIREPURG) is in “alarm”: HVAC mode: ("Smoke Purge ")} Else If: Someone changed the machine’s control type (ConfigurationUNITC.TYP) during run time, a 15 second delay is called out: { HVAC mode: ("Disabled ") OFF} Else If: The System Mode is TEST: { HVAC mode: ("Test ")} Else If: The “soft stop” command (Service TestS.STP) is forced to YES: { HVAC mode: ("SoftStop Request")} Else If: The remote switch config (Configuration UNITRM.CF)=2; “start/stop”, and the remote input state (InputsGEN.IREMT)=ON: { HVAC mode: ("Rem. Sw. Disable") OFF} Else If: Configured for static pressure control (ConfigurationSPSP.CF = 1,2) and the static pressure sensor (PressuresAIR.PSP) fails: { HVAC mode: ("Static Pres.Fail") OFF} Else If: Configured for supply fan status monitoring (ConfigurationUNITSFS.M = 1,2) and configured to shut the unit down on fan status fail (ConfigurationUNITSFS.S = YES) { HVAC mode: ("Fan Status Fail ") OFF} Else If: The unit is just waking up from a power reset { HVAC mode: ("Starting Up ") OFF} Else If: A compressor is diagnosed as being “Stuck On” { HVAC mode: ("Comp. Stuck On ") Else The control is free to select the normal heating/ cooling HVAC modes: 170 APPENDIX E — UPC OPEN CONTROLLER 5 6 6 2 34 7 8 9 0 10's 1 user must give the UPC Open controller an address that is unique on the BACnet* network. Perform the following procedure to assign an address: 1. If the UPC Open controller is powered, pull the screw terminal connector from the controller's power terminals labeled Gnd and HOT. The controller reads the address each time power is applied to it. 2. Using the rotary switches (see Fig. A and B), set the controller's address. Set the Tens (10's) switch to the tens digit of the address, and set the Ones (1's) switch to the ones digit. As an example in Fig. A, if the controller’s address is 25, point the arrow on the Tens (10's) switch to 2 and the arrow on the Ones (1's) switch to 5. 5 To Address the UPC Open Controller — The 2 34 7 8 9 0 1 The following section is used to configure the UPC Open. The UPC Open controller is mounted in a separate enclosure below the main control box. a48-8578 1's Fig. A — Address Rotary Switches BACNET DEVICE INSTANCE ADDRESS — The UPC Open controller also has a BACnet Device Instance address. This Device Instance MUST be unique for the complete BACnet system in which the UPC Open controller is installed. The Device Instance is auto generated by default and is derived by adding the MAC address to the end of the Network Number. The Network Number of a new UPC Open controller is 16101, but it can be changed using i-Vu® Tools or BACView device. By default, a MAC address of 20 will result in a Device Instance of 16101 + 20 which would be a Device Instance of 1610120. a48-8579 BT485 TERMINATOR BACNET CONNECTION (BAS PORT) POWER LED Tx1 LED Rx1 LED Tx2 LED Rx2 LED 23 45 01 8 67 9 EIA-485 JUMPERS 01 8 67 9 23 45 BACNET BAUD RATE DIP SWITCHES ADDRESS ROTARY SWITCHES RUN LED ERROR LED Fig. B — UPC Open Controller * Sponsored by ASHRAE (American Society of Heating, Refrigerating, and Air Conditioning Engineers). 171 APPENDIX E — UPC OPEN CONTROLLER (cont) Configuring the BAS Port for BACnet MS/ TP — Use the same baud rate and communication settings for all controllers on the network segment. The UPC Open controller is fixed at 8 data bits, No Parity, and 1 Stop bit for this protocol's communications. If the UPC Open controller has been wired for power, pull the screw terminal connector from the controller's power terminals labeled Gnd and HOT. The controller reads the DIP Switches and jumpers each time power is applied to it. Set the BAS Port DIP switch DS3 to “enable.” Set the BAS Port DIP switch DS4 to “E1485.” Set the BMS Protocol DIP switches DS8 through DS5 to”MSTP.” See Table A. a48-8580 Fig. C — DIP Switches Table A — SW3 Protocol Switch Settings for MS/TP DS8 Off DS7 Off DS6 Off DS5 Off DS4 On Wire the controllers on an MS/TP network segment in a daisy-chain configuration. Wire specifications for the cable are 22 AWG (American Wire Gage) or 24 AWG, low-capacitance, twisted, stranded, shielded copper wire. The maximum length is 2000 ft. Install a BT485 terminator on the first and last controller on a network segment to add bias and prevent signal distortions due to echoing. See Fig. B, D, and E. To wire the UPC Open controller to the BAS network: 1. Pull the screw terminal connector from the controller's BAS Port. 2. Check the communications wiring for shorts and grounds. 3. Connect the communications wiring to the BAS port’s screw terminals labeled Net +, Net -, and Shield. NOTE: Use the same polarity throughout the network segment. 4. Insert the power screw terminal connector into the UPC Open controller's power terminals if they are not currently connected. 5. Verify communication with the network by viewing a module status report. To perform a module status report using the BACview keypad/display unit, press and hold the “FN” key then press the “.” Key. DS3 Off Verify that the EIA-485 jumpers below the CCN Port are set to EIA-485 and 2W. The example in Fig. C shows the BAS Port DIP Switches set for 76.8k (Carrier default) and MS/TP. Set the BAS Port DIP Switches DS2 and DS1 for the appropriate communications speed of the MS/TP network (9600, 19.2k, 38.4k, or 76.8k bps). See Fig. C and Table B. Table B — Baud Selection Table BAUD RATE 9,600 19,200 38,400 76,800 DS2 Off On Off On DS1 Off Off On On Wiring the UPC Open Controller to the MS/TP Network — The UPC Open controller communicates using BACnet on an MS/TP network segment communications at 9600 bps, 19.2 kbps, 38.4 kbps, or 76.8 kbps. Fig. D — Network Wiring a48-8581 172 APPENDIX E — UPC OPEN CONTROLLER (cont) a48-8582 Fig. E — BT485 Terminator Installation temperature rating specifications list two acceptable alternatives. The Halar specification has a higher temperature rating and a tougher outer jacket than the SmokeGard specification, and it is appropriate for use in applications where the user is concerned about abrasion. The Halar jacket is also less likely to crack in extremely low temperatures. NOTE: Use the specified type of wire and cable for maximum signal integrity. To install a BT485 terminator, push the BT485 terminator, on to the BT485 connector located near the BACnet connector. NOTE: The BT485 terminator has no polarity associated with it. To order a BT485 terminator, consult Commercial Products i-Vu® Open Control System Master Prices. MS/TP Wiring Recommendations — Recommen- dations are shown in Tables C and D. The wire jacket and UL Table C — MS/TP Wiring Recommendations SPECIFICATION Cable Conductor Insulation Color code Twist Lay Shielding Jacket DC resistance Capacitance Characteristic impedance Weight UL Temperature Rating Voltage Listing AWG CL2P DC FEP NEC O.D. TC UL — — — — — — — — RECOMMMENDATION Single twisted pair, low capacitance, CL2P, 22 AWG (7x30), TC foam FEP, plenum rated cable 22 or 24 AWG stranded copper (tin plated) Foamed FEP 0.015 in. (0.381 mm) wall 0.060 in. (1.524 mm) O.D. Black/White 2 in. (50.8 mm) lay on pair 6 twists/foot (20 twists/meter) nominal Aluminum/Mylar shield with 24 AWG TC drain wire SmokeGard Jacket (SmokeGard PVC) 0.021 in. (0.5334 mm) wall 0.175 in. (4.445 mm) O.D. Halar Jacket (E-CTFE) 0.010 in. (0.254 mm) wall 0.144 in. (3.6576 mm) O.D. 15.2 Ohms/1000 feet (50 Ohms/km) nominal 12.5 pF/ft (41 pF/meter) nominal conductor to conductor 100 Ohms nominal 12 lb/1000 feet (17.9 kg/km) SmokeGard 167°F (75°C) Halar -40 to 302°F (-40 to 150°C) 300 Vac, power limited UL: NEC CL2P, or better LEGEND American Wire Gage Class 2 Plenum Cable Direct Current Fluorinated Ethylene Polymer National Electrical Code Outside Diameter Tinned Copper Underwriters Laboratories 173 APPENDIX E — UPC OPEN CONTROLLER (cont) Table D — Open System Wiring Specifications and Recommended Vendors WIRING SPECIFICATIONS Wire Type RECOMMENDED VENDORS AND PART NUMBERS Connect Air Contractors Belden RMCORP Wire and Cable International Description 22 AWG, single twisted shielded pair, low capacitance, CL2P, TC foam FEP, plenum rated. See MS/TP Installation Guide for specifications. MS/TP Network (RS-485) 24 AWG, single twisted shielded pair, low capacitance, CL2P, TC foam FEP, plenum rated. See MS/TP Installation Guide for specifications. Rnet 4 conductor, unshielded, CMP, 18 AWG, plenum rated. AWG CL2P CMP FEP TC — — — — — W221P-22227 — 25160PV CLP0520LC W241P-2000F 82841 25120-OR — W184C-2099BLB 6302UE 21450 CLP0442 LEGEND American Wire Gage Class 2 Plenum Cable Communications Plenum Rated Fluorinated Ethylene Polymer Tinned Copper be running on a laptop computer that is connected to the local access port on the UPC Open controller. The laptop will require an additional USB link cable for connection. See the BACview Installation and User Guide for instructions on connecting and using the BACview6 device. To order a BACview6 Handheld (BV6H), consult Commercial Products i-Vu Open Control System Master Prices. Local access to the UPC Open — The user can use a BACview6 handheld keypad display unit or the Virtual BACview software as a local user interface to an Open controller. These items let the user access the controller network information. These are accessory items and do not come with the UPC Open controller. The BACview6 unit connects to the local access port on the UPC Open controller. See Fig. F. The BACview software must a48-8583 Fig. F — BACview6 Device Connection 174 APPENDIX E — UPC OPEN CONTROLLER (cont) Troubleshooting — If there are problems wiring or ad- Configuring the UPC Open Controller's Properties — The UPC Open device and ComfortLink™ con- dressing the UPC Open controller, contact Carrier Technical Support. COMMUNICATION LEDS — The LEDs indicate if the controller is communicating with the devices on the network. See Tables E and F. The LEDs should reflect communication traffic based on the baud rate set. The higher the baud rate the more solid the LEDs become. See Fig. B for location of LEDs on UPC Open module. REPLACING THE UPC OPEN BATTERY — The UPC Open controller's 10-year lithium CR2032 battery provides a minimum of 10,000 hours of data retention during power outages. trols must be set to the same CCN Address (Element) number and CCN Bus number. The factory default settings for CCN Element and CCN Bus number are 1 and 0 respectively. If modifications to the default Element and Bus number are required, both the ComfortLink and UPC Open configurations must be changed. The following configurations are used to set the CCN Address and Bus number in the ComfortLink controls. These configurations can be changed using the scrolling marquee display or accessory Navigator handheld device. Configuration→CCN→CCN.A (CCN Address) Configuration→CCN→CCN.B (CCN Bus Number) The following configurations are used to set the CCN Address and Bus Number in the UPC Open controller. These configurations can be changed using the accessory BACview6 display. Navigation: BACview→CCN Home: Element Comm Stat Element: 1 Bus: 0 IMPORTANT: Power must be ON to the UPC Open when replacing the battery, or the date, time, and trend data will be lost. Remove the battery from the controller, making note of the battery's polarity. Insert the new battery, matching the battery's polarity with the polarity indicated on the UPC Open controller. Table E — LED Status Indicators LED Power Rx Tx Run Error STATUS Lights when power is being supplied to the controller. The UPC Open controller is protected by internal solid-state polyswitches on the incoming power and network connections. These polyswitches are not replaceable and will reset themselves if the condition that caused the fault returns to normal. Lights when the controller receives data from the network segment; there is an Rx LED for Ports 1 and 2. Lights when the controller transmits data to the network segment; there is an Rx LED for Ports 1 and 2. Lights based on controller status. See Table F. Lights based on controller status. See Table F. Table F — Run and Error LEDs Controller and Network Status Indication RUN LED 2 flashes per second 2 flashes per second 2 flashes per second 2 flashes per second 2 flashes per second 5 flashes per second 5 flashes per second 7 flashes per second 14 flashes per second ERROR LED Off 2 flashes, alternating with Run LED 3 flashes, then off 1 flash per second On On Off 7 flashes per second, alternating with Run LED 14 flashes per second, alternating with Run LED 175 STATUS Normal Five minute auto-restart delay after system error Controller has just been formatted Controller is alone on the network Exec halted after frequent system errors or control programs halted Exec start-up aborted, Boot is running Firmware transfer in progress, Boot is running Ten second recovery period after brownout Brownout APPENDIX E — UPC OPEN CONTROLLER (cont) NETWORK POINTS LIST BACNET OBJECT ID POINT NAME READ ONLY UNITS DEFAULT VALUE RANGE BACNET OBJECT NAME UNIT POINT AV:9 Active Demand Limit W % n/a 0-100 dem_lim_1 DEM_LIM AV:10 Air Temp Lvg Supply Fan R °F n/a n/a sat_1 SAT AV:11 CEM AN1 4-20 ma J5,1-2 W mA n/a 0-20 cem4201_1 CEM4201 AV:12 CEM AN1 10K temp J5,1-2 W °F n/a -40-240 cem10k1_1 CEM10K1 AV:13 CEM AN2 4-20 ma J5,3-4 W mA n/a 0-20 cem4202_1 CEM4202 AV:14 CEM AN2 10K temp J5,3-4 W °F n/a -40-240 cem10k2_1 CEM10K2 AV:15 Temper Supply Air Setpt W °F n/a 0-100 sasptemp_1 SASPTEMP AV:16 BP PID Evaluation Time Level W min 1 0-10 bpperiod_1 BPPERIOD AV:17 BP Setpoint Offset W in H2O 0.05 0-0.5 bpso_1 BPSO AV:18 BP Threshold Adjustment W n/a 1 0.1-10 bpz_gain_1 BPZ_GAIN AV:22 Capacity Load Factor R % n/a n/a smz_1 SMZ AV:23 Capacity Threshold Adj W n/a 1 0-10 z_gain_1 Z_GAIN AV:24 Compressor A1 Run Hours R hr n/a n/a hr_a1_1 HR_A1 AV:25 Compressor A1 Starts R n/a n/a n/a cy_a1_1 CY_A1 AV:26 Compressor A1 Strikes R n/a n/a n/a cmpa1str_1 CMPA1STR AV:27 Compressor A1 Timeguard R n/a n/a n/a cmpa1_tg_1 CMPA1_TG AV:28 Compressor A2 Run Hours R hr n/a n/a hr_a2_1 HR_A2 AV:29 Compressor A2 Starts R n/a n/a n/a cy_a2_1 CY_A2 AV:30 Compressor A2 Strikes R n/a n/a n/a cmpa2str_1 CMPA2STR AV:31 Compressor A2 Timeguard R n/a n/a n/a cmpa2_tg_1 CMPA2_TG AV:32 Compressor B1 Run Hours R hr n/a n/a hr_b1_1 HR_B1 AV:33 Compressor B1 Starts R n/a n/a n/a cy_b1_1 CY_B1 AV:34 Compressor B1 Strikes R n/a n/a n/a cmpb1str_1 CMPB1STR AV:35 Compressor B1 Timeguard R n/a n/a n/a cmpb1_tg_1 CMPB1_TG AV:36 Compressor B2 Run Hours R hr n/a n/a hr_b2_1 HR_B2 AV:37 Compressor B2 Starts R n/a n/a n/a cy_b2_1 CY_B2 AV:38 Compressor B2 Strikes R n/a n/a n/a cmpb2str_1 CMPB2STR AV:39 Compressor B2 Timeguard R n/a n/a n/a cmpb2_tg_1 CMPB2_TG AV:40 Compressor Lockout Temp W °F 40 -20-55 oatlcomp_1 OATLCOMP AV:41 Cool Trend Demand Level W °^F 0.1 0.1-5 ctrendlv_1 CTRENDLV AV:42 Cool Trend Time (secs) W sec 120 30-600 ctrendtm_1 CTRENDTM AV:43 Ctl.Temp RAT,SPT or ZONE R °F n/a n/a ctrltemp_1 CTRLTEMP AV:44 Current Running Capacity R % n/a n/a htsg_cap_1 HTSG_CAP AV:45 DAQ PPM Fan Off Setpoint W n/a 200 0-2000 daqfnoff_1 DAQFNOFF AV:46 DAQ PPM Fan On Setpoint W n/a 400 0-2000 daqfnon_1 DAQFNON AV:49 Dehumidify Cool Setpoint W °F 45 40-55 dhcoolsp_1 DHCOOLSP AV:50 Dehumidify RH Setpoint W % 55 10-90 dhrelhsp_1 DHRELHSP AV:52 Demand Limit Select W n/a 0 0-3 dmd_ctrl_1 DMD_CTRL AV:53 Demand Limit Sw.1 Setpt. W % 80 0-100 dlswsp1_1 DLSWSP1 AV:54 Demand Limit Sw.2 Setpt. W % 50 0-100 dlswsp2_1 DLSWSP2 AV:56 Diff.Air Quality in PPM R n/a n/a n/a daq_1 DAQ AV:58 Diff. AQ Responsiveness W n/a 0 -5-5 iaqreact_1 IAQREACT AV:59 Dmd Level(-) Low Cool OFF W °^F 1 0.5-2 dmdlcoff_1 DMDLCOFF AV:60 Dmd Level(-) Low Heat OFF W °^F 1 0.5-2 dmdlhoff_1 DMDLHOFF See legend on page 182. 176 APPENDIX E — UPC OPEN CONTROLLER (cont) NETWORK POINTS LIST (cont) BACNET OBJECT ID POINT NAME READ ONLY UNITS DEFAULT VALUE RANGE BACNET OBJECT NAME UNIT POINT AV:61 Dmd Level(+) Hi Cool ON W °^F 0.5 0.5-20 dmdhcon_1 DMDHCON AV:62 Dmd Level(+) Hi Heat ON W °^F 0.5 0.5-20 dmdhhon_1 DMDHHON AV:63 Dmd Level Low Cool ON W °^F 1.5 0.5-2 dmdlcon_1 DMDLCON AV:64 Dmd Level Low Heat ON W °^F 1.5 0.5-2 dmdlhon_1 DMDLHON AV:66 Econo Current Min. Pos. R % n/a n/a min_pos_1 MIN_POS AV:67 Economizer Act. Cmd. Pos. W % n/a 0-100 econocmd_1 ECONOCMD AV:68 Economizer Control Point R °F n/a n/a econpnt_1 ECONCPNT AV:70 Economizer Max.Position W % 98 0-100 economax_1 ECONOMAX AV:76 Evaporator Discharge Tmp R °F n/a n/a edt_1 EDT AV:77 Fan Mode W n/a 1 0-1 fan_mode_1 FAN_MODE AV:78 Fan-Off Delay, Elec Heat W n/a 30 10-600 elec_fod_1 ELEC_FOD AV:79 Fan-Off Delay, Gas Heat W n/a 45 45-600 gas_fod_1 GAS_FOD AV:80 Fan-Off Delay, Mech Cool W sec 60 0-600 cool_fod_1 COOL_FOD AV:83 Heat-Cool Setpoint Gap W °^F 5 2-10 hcsp_gap_1 HCSP_GAP AV:85 Heating Supply Air Setpt W °F 85 80-120 saspheat_1 SASPHEAT AV:86 High BP Level W n/a 0.05 0-1 bphplvl_1 BPHPLVL AV:87 Low BP Level W n/a 0.04 0-1 bplplvl_1 BPLPLVL AV:93 IAQ Econo Override Pos. W % 100 0-100 iaqovpos_1 IAQOVPOS AV:95 IAQ High Reference W n/a 2000 0-5000 iaqrefh_1 IAQREFH AV:96 IAQ Low Reference W n/a 0 0-5000 iaqrefl_1 IAQREFL AV:97 IAQ Min.Pos.Override W % n/a 0-100 iaqminov_1 IAQMINOV AV:98 IAQ Purge Duration W min 15 5-60 iaqptime_1 IAQPTIME AV:99 IAQ Purge HiTemp Min Pos W % 35 0-100 iaqphtmp_1 IAQPHTMP AV:100 IAQ Purge LoTemp Min Pos W % 10 0-100 iaqpltmp_1 IAQPLTMP AV:101 IAQ Purge OAT Lockout W °F 50 35-70 iaqpntlo_1 IAQPNTLO AV:102 LAT Limit Config W °^F 10 0-20 htlatlim_1 HTLATLIM AV:107 Maximum Heat Stages R n/a n/a n/a htmaxstg_1 HTMAXSTG AV:112 OAQ Lockout Value W n/a 0 0-2000 oaqlock_1 OAQLOCK AV:113 OAQ - PPM Outdoor CO2 W n/a n/a 0-5000 oaq_1 OAQ AV:114 Occupied Cool Mode End R °F n/a n/a occl_end_1 OCCL_END AV:115 Occupied Cool Mode Start R °F n/a n/a occlstrt_1 OCCLSTRT AV:116 Occupied Heat Mode End R °F n/a n/a ocht_end_1 OCHT_END AV:117 Occupied Heat Mode Start R °F n/a n/a ochtstrt_1 OCHTSTRT AV:118 Outside Air Humidity Ratio R n/a n/a n/a oa_humr_1 OA_HUMR AV:119 Outside Air Relative Humidity W % n/a 0-100 oarh_1 OARH AV:120 Override Time Limit W hr 1 0-4 otl_1 OTL AV:121 Power Exhaust Motors W n/a 1 0-2 pwrm_1 PWRM AV:122 Power Exhaust On Setp.1 W % 35 0-100 pes1_1 PES1 AV:123 Power Exhaust On Setp.2 W % 75 0-100 pes2_1 PES2 AV:130 Remote Switch Config W n/a 0 0-3 rmtincfg_1 RMTINCFG AV:131 Reset Limit W °^F 10 0-20 limt_1 LIMT AV:132 Reset Ratio W n/a 2 0-10 rtio_1 RTIO AV:133 Return Air Enthalpy R n/a n/a n/a rae_1 RAE See legend on page 182. 177 APPENDIX E — UPC OPEN CONTROLLER (cont) NETWORK POINTS LIST (cont) BACNET OBJECT ID POINT NAME READ ONLY UNITS DEFAULT VALUE RANGE BACNET OBJECT NAME UNIT POINT AV:134 Return Air Relative Humidity W % n/a 0-100 rarh_1 RARH AV:135 Return Air Temperature W °F n/a -40-240 rat_1 RAT AV:136 Schedule Number W n/a 0 0-99 schednum_1 SCHEDNUM AV:137 Space Temperature W °F n/a -40-240 spt_1 SPT AV:138 Space Temperature Offset W °^F n/a -10-10 spto_1 SPTO AV:139 Space Temp Offset Range W °^F 5 1-10 spto_rng_1 SPTO_RNG AV:143 SP Reset Limit W n/a 0.75 0-2 sprlimit_1 SPRLIMIT AV:144 SP Reset Ratio W n/a 0.2 0-2 sprratio_1 SPRRATIO AV:150 Staged Gas LAT 1 R °F n/a n/a lat1sgas_1 LAT1SGAS AV:151 Staged Gas LAT 2 R °F n/a n/a lat2sgas_1 LAT2SGAS AV:152 Staged Gas LAT 3 R °F n/a n/a lat3sgas_1 LAT3SGAS AV:153 Staged Gas LAT Sum R °F n/a n/a lat_sgas_1 LAT_SGAS AV:154 Staged Gas Limit Sw Temp R °F n/a n/a limswtmp_1 LIMSWTMP AV:155 Startup Delay Time W sec 0 0-900 delay_1 DELAY AV:156 Stat. Pres. Reset Config W n/a 0 0-4 sprstcfg_1 SPRSTCFG AV:157 Static Pressure Reset W n/a n/a 0-15 spreset_1 SPRESET AV:158 Supply Air Setpnt. Reset W °^F n/a 0-20 sasprset_1 SASPRSET AV:159 Temp Comp Start Cool Factor W min 0 0-60 tcstcool_1 TCSTCOOL AV:160 Temp Comp Start Heat Factor W min 0 0-60 tcstheat_1 TCSTHEAT AV:161 Tempering in Cool SASP W n/a 5 5-75 tempcool_1 TEMPCOOL AV:162 Tempering Purge SASP W n/a 50 -20-80 temppurg_1 TEMPPURG AV:163 Tempering Vent Occ SASP W n/a 65 -20-80 tempvocc_1 TEMPVOCC AV:164 Temper Vent Unocc W n/a 50 -20-80 tempvunc_1 TEMPVUNC AV:165 Supply Fan VFD Speed W % n/a 0-100 sf_vfd_output_1 SFVFDTST AV:166 Un.Ec.Free Cool OAT Lock W °F 50 40-70 uefcntlo_1 UEFCNTLO AV:168 Unoccupied Cool Mode End R °F n/a n/a uccl_end_1 UCCL_END AV:169 Unoccupied Cool Mode Start R °F n/a n/a ucclstrt_1 UCCLSTRT AV:170 Unoccupied Heat Mode End R °F n/a n/a ucht_end_1 UCHT_END AV:171 Unoccupied Heat Mode Start R °F n/a n/a uchtstrt_1 UCHTSTRT AV:172 Unoc Econ Free Cool Cfg W n/a 0 0-2 uefc_cfg_1 UEFC_CFG AV:173 Unoc Econ Free Cool Time W min 120 0-720 uefctime_1 UEFCTIME AV:179 User Determined OAQ W n/a 400 0-5000 oaq_user_1 OAQ_USER AV:180 VAV Occ. Cool Off Delta W °^F 2 1-25 vavocoff_1 VAVOCOFF AV:181 VAV Occ. Cool On Delta W °^F 3.5 0-25 vavocon_1 VAVOCON AV:182 VAV Unocc Fan Retry Time W min 60 0-720 sampmins_1 SAMPMINS AV:183 Vent Reheat RAT Offset W °^F 0 0-8 dhvraoff_1 DHVRAOFF AV:184 Vent Reheat Setpoint W °F 70 55-95 dhvht_sp_1 DHVHT_SP AV:185 Vent Reheat Setpt Select W n/a 0 0-1 dhvhtcfg_1 DHVHTCFG AV:186 VFD/Act. Fire Speed/Pos. W % 100 0-100 bldgpfso_1 BLDGPFSO AV:187 VFD Fire Speed Override W % 100 0-100 statpfso_1 STATPFSO AV:188 VFD Maximum Speed W % 100 0-100 statpmax_1 STATPMAX AV:189 VFD Minimum Speed W % 20 0-100 statpmin_1 STATPMIN AV:1003 Outside Air Temperature W °F n/a -40-240 oat_1 OAT See legend on page 182. 178 APPENDIX E — UPC OPEN CONTROLLER (cont) NETWORK POINTS LIST (cont) BACNET OBJECT ID POINT NAME READ ONLY UNITS DEFAULT VALUE RANGE BACNET OBJECT NAME UNIT POINT AV:1009 IAQ - PPM Indoor CO2 W n/a n/a 0-5000 iaq_1 IAQ AV:1016 Static Pressure R in H2O n/a n/a static_press_1 SP AV:1022 HVAC Mode Numerical Form R n/a n/a n/a hvac_mode_1 MODEHVAC AV:1023 Current Running Capacity R % n/a n/a cool_capacity_1 CAPTOTAL AV:1024 Cooling Control Point R °F n/a n/a cool_ctrl_point_1 COOLCPNT AV:1025 Heating Control Point R °F n/a n/a heat_ctrl_point_1 HEATCPNT AV:1027 Leaving Air Temperature R °F n/a n/a lvg_air_temperature_1 LAT AV:1028 Economizer Act. Curr. Pos R % n/a n/a econ_pos_1 ECONOPOS AV:1030 Controlling Return Temp W °F n/a -40-240 ra_temp_1 RETURN_T AV:1070 Building Pressure R in H2O n/a n/a bldg_static_press_1 BP AV:1500 Mixed Air Temperature R °F n/a n/a ma_temp_1 MAT AV:1600 Cir A Suction Pressure R psig n/a n/a suction_press_a_1 SP_A AV:1601 Cir A Discharge Pressure R psig n/a n/a discharge_press_a_1 DP_A AV:1602 Cir A Sat. Condensing Temperature R °F n/a n/a sat_cond_temp_a_1 SCTA AV:1603 Cir A Sat. Suction Temperature R °F n/a n/a sat_suction_temp_a_1 SSTA AV:1604 Cir B Suction Pressure R psig n/a n/a suction_press_b_1 SP_B AV:1605 Cir B Discharge Pressure R psig n/a n/a discharge_press_b_1 DP_B AV:1606 Cir B Sat. Condensing Temperature R °F n/a n/a sat_cond_temp_b_1 SCTB AV:1607 Cir B Sat. Suction Temperature R °F n/a n/a sat_suction_temp_b_1 SSTB AV:2003 Requested Heat Stage R n/a n/a n/a heat_run_1 HT_STAGE AV:2007 Controlling Space Temp W °F n/a -40-240 space_temp_1 SPACE_T AV:2050 Supply Fan VFD Speed R % n/a n/a sfvfdtst_1 SFAN_VFD AV:2075 Exhaust Fan VFD Speed R % n/a n/a ef_vfd_output_1 EFAN_VFD AV:2901 User Defined Analog 1 n/a n/a n/a n/a user_analog_1_1 n/a AV:2902 User Defined Analog 2 n/a n/a n/a n/a user_analog_2_1 n/a AV:2903 User Defined Analog 3 n/a n/a n/a n/a user_analog_3_1 n/a AV:2904 User Defined Analog 4 n/a n/a n/a n/a user_analog_4_1 n/a AV:2905 User Defined Analog 5 n/a n/a n/a n/a user_analog_5_1 n/a AV:3001 Cooling Occupied Setpoint W °F 75 40-99 occ_cl_stpt_1 OCSP AV:3002 Heating Occupied Setpoint W °F 68 409-99 occ_ht_stpt_1 OHSP AV:3003 Cooling Unoccupied Setpoint W °F 90 40-99 unocc_cl_stpt_1 UCSP AV:3004 Heating Unoccupied Setpoint W °F 55 40-99 unocc_ht_stpt_1 UHSP AV:3007 Supply Air Setpoint W °F 55 45-75 sa_temp_stpt_1 SASP AV:3016 IAQ Demand Vent Min.Pos. W % 0 0-100 iaq_min_pos_1 IAQMINP AV:3050 Static Pressure Setpoint W in H2O 1.5 0-5 sa_static_stpt_1 SPSP 0.05 -0.250.25 bldg_press_stpt_1 BPSP AV:3070 Building Pressure Setp. W in H2O AV:4005 Economizer Min.Position W % 5 0-100 econ_min_1 ECONOMIN AV:9008 High OAT Lockout Temp W °F 60 -40-120 econ_oat_lockout_1 OAT_LOCK See legend on page 182. 179 APPENDIX E — UPC OPEN CONTROLLER (cont) NETWORK POINTS LIST (cont) BACNET OBJECT ID POINT NAME READ ONLY UNITS DEFAULT VALUE RANGE BACNET OBJECT NAME UNIT POINT BV:9 Alarm State R n/a n/a n/a alm_1 ALM BV:10 Capacity Clamp Mode R n/a n/a n/a capmode_1 CAPMODE BV:11 Fan request from IGC R n/a n/a n/a igcfan_1 IGCFAN BV:12 Comp A1 Locked Out ? R n/a n/a n/a cmpa1lok_1 CMPA1LOK BV:13 Comp A2 Locked Out ? R n/a n/a n/a cmpa2lok_1 CMPA2LOK BV:14 Comp B1 Locked Out ? R n/a n/a n/a cmpb1lok_1 CMPB1LOK BV:15 Comp B2 Locked Out ? R n/a n/a n/a cmpb2ok_1 CMPB2LOK BV:16 Compressor A1 Relay R n/a n/a n/a cmpa1_1 CMPA1 BV:17 Compressor A2 Relay R n/a n/a n/a cmpa2_1 CMPA2 BV:18 Compressor B1 Relay R n/a n/a n/a cmpb1_1 CMPB1 BV:19 Compressor B2 Relay R n/a n/a n/a cmpb2_1 CMPB2 BV:20 Cool Mode Not In Effect? R n/a n/a n/a cool_off_1 COOL_OFF BV:21 Override Modes in Effect R n/a n/a n/a modes_1 MODES BV:22 Supply Fan not on 30s ? R n/a n/a n/a sfonstat_1 SFONSTAT BV:25 DBC - OAT Lockout? R n/a n/a n/a dbc_stat_1 DBC_STAT BV:26 DCV Resetting Min Pos R n/a n/a n/a modeadcv_1 MODEADCV BV:27 DDBC- OAT > RAT Lockout? R n/a n/a n/a ddbcstat_1 DDBCSTAT BV:28 DEC - Diff.Enth.Lockout? R n/a n/a n/a dec_stat_1 DEC_STAT BV:29 Dehumid. Disabled Econ.? R n/a n/a n/a dhdisabl_1 DHDISABL BV:30 Dehumidify Input W n/a n/a 0-1 dhdiscin_1 DHDISCIN BV:31 Demand Limit In Effect R n/a n/a n/a modedmlt_1 MODEDMLT BV:32 DEW - OA Dewpt.Lockout? R n/a n/a n/a dew_stat_1 DEW_STAT BV:34 Econ Act. Unavailable? R n/a n/a n/a econunav_1 ECONUNAV BV:35 Econ disable in DH mode? W n/a 1 0-1 dhecdisa_1 DHECDISA BV:36 Economizer Active? R n/a n/a n/a ecactive_1 ECACTIVE BV:37 Economizer Control Input W n/a n/a 0-1 ecosw_1 ECOSW BV:38 Economizer Forced ? R n/a n/a n/a econforc_1 ECONFORC BV:41 Econo Position Override W n/a n/a 0-1 ecooride_1 ECOORIDE BV:42 Econ Recovery Hold Off? R n/a n/a n/a econheld_1 ECONHELD BV:44 EDT Sensor Bad ? R n/a n/a n/a edt_stat_1 EDT_STAT BV:45 Emergency Stop W n/a n/a 0-1 emstop_1 EMSTOP BV:46 Enable Compressor A1 W n/a Enable 0-1 cmpa1ena_1 CMPA1ENA BV:47 Enable Compressor A2 W n/a Enable 0-1 cmpa2ena_1 CMPA2ENA BV:48 Enable Compressor B1 W n/a Enable 0-1 cmpb1ena_1 CMPB1ENA BV:49 Enable Compressor B2 W n/a Enable 0-1 cmpb2ena_1 CMPB2ENA BV:50 Fan Fail Shuts Down Unit W n/a 0 0-1 sfs_shut_1 SFS_SHUT BV:52 Heat Relay 1 R n/a n/a n/a hs1_1 HS1 BV:53 Heat Relay 2 R n/a n/a n/a hs2_1 HS2 BV:54 High BP Override R n/a n/a n/a bphpovrd_1 BPHPOVRD BV:55 Hi Limit Switch Tmp Mode R n/a n/a n/a limtmode_1 LIMTMODE BV:56 IAQ Pre-Occ Purge Active R n/a n/a n/a modeiqpg_1 MODEIQPG BV:57 IAQ Purge W n/a 0 0-1 iaqpurge_1 IAQPURGE BV:58 LAT Cutoff Mode R n/a n/a n/a latcmode_1 LATCMODE See legend on page 182. 180 APPENDIX E — UPC OPEN CONTROLLER (cont) NETWORK POINTS LIST (cont) BACNET OBJECT ID POINT NAME READ ONLY UNITS DEFAULT VALUE RANGE BACNET OBJECT NAME UNIT POINT BV:59 Local Machine Disable W n/a No 0-1 unitstop_1 UNITSTOP BV:60 Low BP Override R n/a n/a n/a bplpovrd_1 BPLPOVRD BV:61 Low Temp Cap Override R n/a n/a n/a low_temp_1 LOW_TEMP BV:63 Mech Cooling Locked Out R n/a n/a n/a modelock_1 MODELOCK BV:64 Min. Load Valve (HGBP) R n/a n/a n/a mlv_1 MLV BV:67 OAEC- OA Enth Lockout? R n/a n/a n/a oaecstat_1 OAECSTAT BV:68 OAQ Lockout In Effect ? R n/a n/a n/a oaqlockd_1 OAQLOCKD BV:69 OAT Sensor Bad ? R n/a n/a n/a oat_stat_1 OAT_STAT BV:70 Occupied Heating Enabled W n/a No 0-1 htoccena_1 HTOCCENA BV:72 Power Exhaust Relay A R n/a n/a n/a pe_a_1 PE_A BV:73 Power Exhaust Relay B R n/a n/a n/a pe_b_1 PE_B BV:74 Power Exhaust Relay C R n/a n/a n/a pe_c_1 PE_C BV:75 Pull Down Cap Override R n/a n/a n/a pulldown_1 PULLDOWN BV:76 Relay 3 W1 Gas Valve 2 R n/a n/a n/a hs3_1 HS3 BV:77 Relay 4 W2 Gas Valve 2 R n/a n/a n/a hs4_1 HS4 BV:78 Relay 5 W1 Gas Valve 3 R n/a n/a n/a hs5_1 HS5 BV:79 Relay 6 W2 Gas Valve 3 R n/a n/a n/a hs6_1 HS6 BV:80 Remote Econ. Disabled ? R n/a n/a n/a econdisa_1 ECONDISA BV:81 Remote Input State W n/a n/a 0-1 rmtin_1 RMTIN BV:86 Slow Change Cap Override R n/a n/a n/a slo_chng_1 SLO_CHNG BV:87 Soft Stop Request W n/a n/a 0-1 softstop_1 SOFTSTOP BV:93 Supply Air Reset R n/a n/a n/a modesars_1 MODESARS BV:94 Supply Fan Relay R n/a n/a n/a sfan_rly_1 SFAN_RLY BV:95 Supply Fan Status Switch W n/a n/a 0-1 sfs_1 SFS BV:96 Temp Compensated Start R n/a n/a n/a modetcst_1 MODETCST BV:97 Timed Override In Effect R n/a n/a n/a modetovr_1 MODETOVR BV:98 Timed-Override in Effect R n/a n/a n/a overlast_1 OVERLAST BV:99 TSTAT Both Heat and Cool W n/a No 0-1 tstatall_1 TSTATALL BV:1005 Fire Shutdown Input W n/a n/a 0-1 firedown_status_1 FSD BV:1006 Demand Limit Switch 1 W n/a n/a 0-1 dmd_sw1_1 DMD_SW1 BV:1007 Demand Limit Switch 2 W n/a n/a 0-1 dmd_sw2_1 DMD_SW2 BV:1010 Remote Economizer Enable W n/a n/a 0-1 remote_econ_enable_1 ECONENBL BV:1017 Thermostat Y1 Input W n/a n/a 0-1 y1_input_1 Y1 BV:1018 Thermostat Y2 Input W n/a n/a 0-1 y2_input_1 Y2 BV:1019 Thermostat W1 Input W n/a n/a 0-1 w1_input_1 W1 BV:1020 Thermostat W2 Input W n/a n/a 0-1 w2_input_1 W2 BV:1021 Thermostat G Input W n/a n/a 0-1 g_input_1 G BV:1026 Heat Interlock Relay W n/a n/a 0-1 heat_interlock_relay_1 HIR BV:1050 IAQ - Discrete Input W n/a n/a 0-1 iaq_status_1 IAQIN See legend on page 182. 181 APPENDIX E — UPC OPEN CONTROLLER (cont) NETWORK POINTS LIST (cont) BACNET OBJECT ID POINT NAME READ ONLY UNITS DEFAULT VALUE RANGE BACNET OBJECT NAME UNIT POINT BV:1052 Filter Status Input W n/a n/a 0-1 filter_status_1 FLTS BV:1060 Evacuation Input W n/a n/a 0-1 smk_evac_1 EVAC BV:1061 Pressurization Input W n/a n/a 0-1 smk_press_1 PRES BV:1062 Smoke Purge Input W n/a n/a 0-1 smk_purg_1 PURG BV:2001 Supply Fan State R n/a n/a n/a sfan_1 SFAN BV:2004 Supply Fan Request W n/a n/a 0-1 sfan_forc_1 SFANFORC BV:2008 Occupied? W n/a n/a 0-1 occ_status_1 OCCUPIED BV:2012 Condenser Fan Circuit A R n/a n/a n/a cond_fan_a_1 CONDFANA BV:2013 Condenser Fan Circuit B R n/a n/a n/a cond_fan_b_1 CONDFANB BV:2014 Remote Alarm/Aux Relay W n/a n/a 0-1 aux_relay_1 ALRM BV:2911 User Defined Binary 1 n/a n/a n/a n/a user_binary_1_1 n/a BV:2912 User Defined Binary 2 n/a n/a n/a n/a user_binary_2_1 n/a BV:2913 User Defined Binary 3 n/a n/a n/a n/a user_binary_3_1 n/a BV:2914 User Defined Binary 4 n/a n/a n/a n/a user_binary_4_1 n/a BV:2915 User Defined Binary 5 n/a n/a n/a n/a user_binary_5_1 n/a BV:2999 Element Comm Status n/a n/a n/a n/a element_stat_1 n/a BP CEM DAQ DBC DDBC DEC DH IAQ LAT n/a OAEC OAT PID R RAT RH SASP SPT TSTAT VAV VFD W — — — — — — — — — — — — — — — — — — — — — — LEGEND Building Pressure Controls Expansion Module Differential Air Quality Dry Bulb Changeover Differential Dry Bulb Changeover Differential Enthalpy Changeover Dehumidification Indoor Air Quality Leaving Air Temperature Not Available Outdoor Air Enthalpy Changeover Outdoor Air Temperature Proportional, Integral, Derivative Read Return Air Temperature Relative Humidity Supply Air Set Point Space Temperature Thermostat Variable Air Volume Variable Frequency Drive Write 182 INDEX Accessory control components 124 Accessory installation 7 Accessory Navigator™ display 4, 124 Airflow control during fire-smoke modes 66 Alarm output 31 Alarms and alerts 93 Alert limit configuration 72 Auto view of run status 90 Basic control usage 3-6 Building pressure configuration 63 Building pressure control 63 Carrier Comfort Network® (CCN) System 71 CCN tables and display 5 CCN tables 148-160 Cleaning 128 ComfortLink™ controls 3 Complete unit stoppage 77 Compressor run hours display table 91 Compressor starts display table 91 Condenser-fan adjustment 132 Controls 7 Controls operation 4, 32-75 Controls quick start 27-29 Controls set point and configuration log CL-1 to CL-5 Conventions used in this manual 3 Cool mode selection process 40 Cooling 30 Cooling control 37 Cooling mode diagnostic help 46 Crankcase heaters 7 Dehumidification and reheat 69 Demand controlled ventilation control 31 Demand limit control 31, 48 Dirty filter switch 60 Discrete switch logic configuration 74 Display configuration 74 Economizer 60 Economizer diagnostic help 63 Economizer integration with mechanical cooling 50 Economizer operation 61 Economizer options 28 Economizer run status 90 Evacuation mode 66 Evaporator fan 7, 130, 131 Exhaust options 29 Factory-installed components 101 Fan status monitoring 59 Fans 30 Filter drier 139 Fire shutdown mode 66 Fire-smoke inputs 66 Four-inch filter replacement 132 Forcing inputs and outputs 90 Gas heat (48A only) 7 Gas valve adjustment (48A only) 132 Generics table 5 Head pressure control 49 Heat mode diagnostic help 52 Heat mode selection process 51 Heating 30 Heating control 50 Hot gas bypass 75 HVAC modes 33 Independent outputs 30 Indoor air quality control 67 Indoor air quality options 29 Internal wiring 7 Local display tables 140-147 Lubrication 130 Main burners 139 Major system components 101-127 Mode selection 170 Mode trip helper 91 Modes 32 Multi-stage constant volume units with mechanical thermostat 28 Multi-stage constant volume units with space sensor 28 Power failure 132 Pressurization mode 66 Programming operating schedules 29 Refrigerant charge 132 Remote control switch input 74 Remote switch 31 Replacement parts 139 Restart procedure 77 Run status menu 90 Safety considerations 2 Scrolling marquee 4, 122 Sensor trim configuration 73 Service 128-139 Service access 128 Service analysis 77 Service test 29, 30 Service test mode logic 29 Single circuit stoppage 77 Smoke control modes 66 Smoke purge mode 66 Software version numbers display table 91 Space temperature offset 75 Staged gas heating control 54-56 Start up 7-27 Static pressure control 57 Static pressure reset 58,59 SumZ cooling algorithm 46 Supply air reset 31 Supply fan status monitoring logic 60 System modes 33 System Pilot™ interface 5 Temperature compensated start 71 Temperature compensated start logic 71 Thermistor troubleshooting 77 Thermostat 31 Thermostatic expansion valve (TXV) 132 Third party control 31,32 Time clock configuration 75-77 Transducer troubleshooting 78 Troubleshooting 77-101 Two-stage constant volume units with mechanical thermostat 27 Two-stage constant volume units with space sensor 27 Unit Configuration submenu 35 Unit preparation 7 Unit setup 7 Unit staging tables 43-45 Unit start-up checklist CL-6 Unoccupied economizer free cooling 62 UPC Open controller 171-182 Variable air volume units using return air sensor or space temperature sensor 28 VFD control 31 VFD information 161-169 183 Copyright 2010 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480077-01 Printed in U.S.A. Form 48/50A-9T Pg 184 6-10 Replaces: 48/50A-7T CONTROLS SET POINT AND CONFIGURATION LOG MODEL NUMBER: Software Version SERIAL NUMBER: MBB CESR131343-- DATE: RCB CESR131249-- TECHNICIAN: ECB CESR131249-- NAVI CESR131227-- SCB CESR131226-- CEM CESR131174-- MARQ CESR131171-- ITEM UNIT C.TYP CV.FN RM.CF CEM TCS.C TCS.H SFS.S SFS.M VAV.S SIZE DP.XR SP.XR RFG.T CND.T MAT.S MAT.R MAT.D ALTI DLAY STAT AUX.R SENS SENSSPT.S SENSSP.O.S SENSSP.O.R SENSRRH.S SENSFLT.S COOL Z.GN MC.LO C.FOD MLV M.M. HPSP A1.EN A2.EN B1.EN B2.EN CS.A1 CS.A2 CS.B1 CS.B2 REV.R H.SST EDT.R RS.CF RTIO LIMT RES.S EXPANSION UNIT CONFIGURATION Machine Control Type Fan Mode (0=Auto, 1=Cont) Remote Switch Config CEM Module Installed Temp.Cmp.Strt.Cool Factr Temp.Cmp.Strt.Heat Factr Fan Fail Shuts Down Unit Fan Stat Monitoring Type VAV Unocc.Fan Retry Time Unit Size (20-60) Disch.Press. Transducers Suct. Pres. Trans. Type Refrig: 0=R22 1=R410A Cnd HX Typ:0=RTPF 1=MCHX MAT Calc Config Reset MAT Table Entries? MAT Outside Air Default Altitude……..in feet: Startup Delay Time TSTAT_Both Heat and Cool Auxiliary Relay Config INPUT SENSOR CONFIG Space Temp Sensor Space Temp Offset Sensor Space Temp Offset Range Return Air RH Sensor Filter Stat.Sw.Enabled ? COOLING CONFIGURATION Capacity Threshold Adjst Compressor Lockout Temp Fan-Off Delay, Mech Cool Min. Load Valve? (HGBP) Motor Master Control Head Pressure Setpoint Enable Compressor A1 Enable Compressor A2 Enable Compressor B1 Enable Compressor B2 CSB A1 Feedback Alarm CSB A2 Feedback Alarm CSB B1 Feedback Alarm CSB B2 Feedback Alarm Rev Rotation Verified ? Hi SST Alert DelayTime EVAP.DISCHRGE TEMP RESET EDT Reset Configuration Reset Ratio Reset Limit EDT 4-20 ma Reset Input RANGE 1 - 6 (multi-text strings) 0 - 1 (multi-text strings) 0 - 3 (multi-text strings) Yes/No 0 - 60 min 0 - 60 min Yes/No 0 - 2 (multi-text strings) 0 - 720 min 20 - 60 Yes/No 0 -1 (multi-text strings) 0 -1 (multi-text strings) 0 -1 (multi-text strings) 0 - 2 (multi-text strings) Yes/No 0-100% 0 - 60000 0 - 900 sec Yes/No 0-3 DEFAULT ENTRY 4 1 0 No 0 0 No 0 50 20 No 0 1 0 1 No 20 0 0 No 0 Enable/Disable Enable/Disable 1 - 10 Enable/Disable Enable/Disable Disable Disable 5 Disable Disable –10- 10 –20 - 55 dF 0 - 600 sec Yes/No Yes/No 80 - 150 dF Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Yes/No 5 - 30 min 1 40 60 No No 113 Enable Enable Enable Enable Enable Enable Enable Enable No 10 0 - 3 (multi-text strings) 0 - 10 0 - 20 ^F Enable/Disable 0 2 10 Disable Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480077-01 Printed in U.S.A. Form 48/50A-9T Pg CL-1 6-10 Replaces: 48/50A-7T EXPANSION HEATING CONFIGURATION Heating Control Type Heating Supply Air Setpt Occupied Heating Enabled MBB Sensor Heat Relocate Fan-Off Delay, Gas Heat Fan-Off Delay, Elec Heat STAGED GAS CONFIGS Staged Gas Heat Type Max Cap Change per Cycle S.Gas DB min.dF/PID Rate St.Gas Temp. Dead Band Heat Rise dF/sec Clamp LAT Limit Config Limit Switch Monitoring? Limit Switch High Temp Limit Switch Low Temp Heat Control Prop. Gain Heat Control Derv. Gain Heat PID Rate Config SUPPLY STATIC PRESS.CFG. Static Pressure Config Static Pres.Fan Control? Static Pressure Sensor Static Press. Low Range Static Press. High Range Static Pressure Setpoint VFD Minimum Speed VFD Maximum Speed VFD Fire Speed Override Stat. Pres. Reset Config SP Reset Ratio (/dF) SP Reset Limit in iwc () SP Reset Econo. Position STAT.PRESS.PID CONFIGS Stat.Pres.PID Run Rate Static Press. Prop. Gain Static Pressure Intg. Gain Static Pressure Derv. Gain Static Press.System Gain ECONOMIZER CONFIGURATION Economizer Installed? Economizer Min.Position Economizer Max.Position Economzr Trim For SumZ ? Econ ChangeOver Select OA Enthalpy ChgOvr Selct Outdr.Enth Compare Value High OAT Lockout Temp OA Dewpoint Temp Limit Outside Air RH Sensor Economizer Control Type Economizer Switch Config ECON.OPERATION CONFIGS Economizer Prop.Gain Economizer Range Adjust Economizer Speed Adjust Economizer Deadband UNOCC.ECON.FREE COOLING Unoc Econ Free Cool Cfg Unoc Econ Free Cool Time Un.Ec.Free Cool OAT Lock RANGE 0-4 80 - 120 dF Yes/No Yes/No 45-600 10-600 0-4 5 - 45 0-5 0 - 5 ^F 0.05 - 0.2 0 - 20 ^F Yes/No 110 - 180 dF 100 - 170 dF 0 - 1.5 0 - 1.5 60 - 300 sec 0 - 1 (multi-text strings) Yes Enable/Disable -10 - 0 0 - 10 0 - 5 "H2O 0 - 100 % 0 - 100 % 0 - 100 % 0 - 4 (multi-text strings) 0 - 2.00 in. wg/dF 0 - 2.00 in. wg 0 - 100 % 1 - 200 sec 0 - 100 0 - 50 0 - 50 0 - 50 Yes/No 0 - 100 % 0 - 100 % Yes/No 0 - 3 (multi-text strings) 1 - 5 (multi-text strings) 18 - 28 –40 - 120 dF 50 - 62 dF Enable/Disable 1-3 (multi-text strings) 0 - 2 (multi-text strings) CL-2 DEFAULT 0 85 No No 45 30 0 45 0.5 2 0.06 10 No 170 160 1 1 90 No Yes Disable 0 5 1.5 20 100 100 0 0.2 0.75 5 2 20 2 0 1 Yes 5 98 Yes 1 4 24 60 55 Disable 1 0 0.7 - 3.0 0.5 - 5.0 ^F 0.1 - 10.0 0.1 - 2.0 ^F 1 2.5 0.75 0.5 0-2 (multi-text strings) 0 - 720 min 40 - 70 dF 0 120 50 ENTRY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE ITEM HEAT HT.CF HT.SP OC.EN LAT.M G.FOD E.FOD SG.CF SG.CFHT.ST SG.CFCAP.M SG.CFM.R.DB SG.CFS.G.DB SG.CFRISE SG.CFLAT.L SG.CFLIM.M SG.CFSW.H.T SG.CFSW.L.T SG.CFHT.P SG.CFHT.D SG.CFHT.TM SP SP.CF SP.FN SP.S SP.LO SP.HI SP.SP SP.MN SP.MX SP.FS SP.RS SP.RT SP.LM SP.EC S.PID S.PIDSP.TM S.PIDSP.P S.PIDSP.I S.PIDSP.D S.PIDSP.SG ECON EC.EN EC.MN EC.MX E.TRM E.SEL OA.E.C OA.EN OAT.L O.DEW ORH.S E.TYP EC.SW E.CFG E.CFGE.P.GN E.CFGE.RNG E.CFGE.SPD E.CFGE.DBD UEFC UEFCFC.CF UEFCFC.TM UEFCFC.L.O ITEM BP BP.CF BP.RT BP.P BP.I BP.D BP.SO BP.MN BP.MX BP.FS BP.MT BP.S BP.R BP.SP BP.P1 BP.P2 B.CFG B.CFGBP.SL B.CFGBP.TM B.CFGBP.ZG B.CFGBP.HP B.CFGBP.LP D.LV.T L.H.ON H.H.ON L.H.OF L.C.ON H.C.ON L.C.OF C.T.LV H.T.LV C.T.TM H.T.TM DMD.L DM.L.S D.L.20 SH.NM SH.DL SH.TM D.L.S1 D.L.S2 IAQ DCV.C DCV.CEC.MN DCV.CIAQ.M AQ.CF AQ.CFIQ.A.C AQ.CFIQ.A.F AQ.CFIQ.I.C AQ.CFIQ.I.F AQ.CFOQ.A.C AQ.SP AQ.SPIQ.O.P AQ.SPDAQ.L AQ.SPDAQ.H AQ.SPD.F.OF AQ.SPD.F.ON AQ.SPIAQ.R AQ.SPOAQ.L AQ.SPOAQ.U AQ.S.R EXPANSION BUILDING PRESS. CONFIG Building Press. Config Bldg.Pres.PID Run Rate Bldg. Press. Prop. Gain Bldg.Press.Integ.Gain Bldg.Press.Deriv.Gain BP Setpoint Offset BP VFD Minimum Speed BP VFD Maximum Speed VFD/Act. Fire Speed/Pos. Power Exhaust Motors Building Pressure Sensor Bldg Press (+/-) Range Building Pressure Setp. Power Exhaust On Setp.1 Power Exhaust On Setp.2 BP ALGORITHM CONFIGS Modulating PE Alg. Slct. BP PID Evaluation Time BP Threshold Adjustment High BP Level Low BP Level COOL/HEAT SETPT. OFFSETS Dmd Level Lo Heat On Dmd Level(+) Hi Heat On Dmd Level(-) Lo Heat Off Dmd Level Lo Cool On Dmd Level(+) Hi Cool On Dmd Level(-) Lo Cool Off Cool Trend Demand Level Heat Trend Demand Level Cool Trend Time Heat Trend Time DEMAND LIMIT CONFIG. Demand Limit Select Demand Limit at 20 ma Loadshed Group Number Loadshed Demand Delta Maximum Loadshed Time Demand Limit Sw.1 Setpt. Demand Limit Sw.2 Setpt. INDOOR AIR QUALITY CFG. DCV ECONOMIZER SETPOINTS Economizer Min.Position IAQ Demand Vent Min.Pos. AIR QUALITY CONFIGS IAQ Analog Sensor Config IAQ 4-20 ma Fan Config IAQ Discrete Input Config IAQ Disc.In. Fan Config OAQ 4-20ma Sensor Config AIR QUALITY SETPOINTS IAQ Econ Override Pos. Diff.Air Quality LoLimit Diff.Air Quality HiLimit DAQ PPM Fan Off Setpoint DAQ PPM Fan On Setpoint Diff. AQ Responsiveness OAQ Lockout Value User Determined OAQ AIR QUALITY SENSOR RANGE RANGE 0-2 5-120 sec 0-5 0-2 0-5 0.0 - 0.5 “H2O 0-100% 0-100% 0-100% 1-2 Enable/Dsable 0 - 1.00 “H2O –0.25 0.25 "H2O 0 - 100 % 0 - 100 % ENTRY 0 10 0.5 0.5 0.3 0.05 10 100 100 1 Dsable 0.25 0.05 35 75 1-3 0 - 10 min 0.1 - 10.0 “H2O 0 - 1.000 “H2O 0 - 1.000 “H2O 1 1 1 0.05 0.04 –1 - 2 ^F 0.5 - 20.0 ^F 0.5 - 2 ^F –1 - 2 ^F 0.5 - 20.0 ^F 0.5 - 2 ^F 0.1 - 5 ^F 0.1 - 5 ^F 30 - 600 sec 30 - 600 sec 1.5 0.5 1 1.5 0.5 1 0.1 0.1 120 120 0 - 3 (multi-text strings) 0 - 100 % 0 - 99 0 - 60 % 0 - 120 min 0 - 100 % 0 - 100 % 0 100 0 0 60 80 50 0 - 100 % 0 - 100 % 5 0 0 - 4 (multi-text strings) 0 - 2 (multi-text strings) 0 - 2 (multi-text strings) 0 - 2 (multi-text strings) 0 - 2 (multi-text strings) 0 0 0 0 0 0 - 100 % 0 - 1000 100 - 2000 0 - 2000 0 - 2000 –5 - 5 0 - 2000 0 - 5000 CL-3 DEFAULT 100 100 700 200 400 0 0 400 DEHU D.SEL D.SEN D.EC.D D.V.CF D.V.RA D.V.HT D.C.SP D.RH.S CCN CCNA CCNB BAUD BROD BRODTM.DT BRODOAT.B BRODORH.B BRODOAQ.B BRODG.S.B BRODB.ACK SC.OV SC.OVSCH.N SC.OVHOL.T SC.OVO.T.L. SC.OVOV.EX SC.OVSPT.O SC.OVT58.O SC.OVGL.OV ALLM SP.L.O SP.H.O SP.L.U SP.H.U SA.L.O SA.H.O SA.L.U SA.H.U RA.L.O RA.H.O RA.L.U RA.H.U R.RH.L R.RH.H SP.L SP.H BP.L BP.H IAQ.H TRIM SAT.T RAT.T OAT.T SPT.T CTA.T CTB.T SP.A.T SP.B.T DP.A.T DP.B.T EXPANSION IAQ Low Reference IAQ High Reference OAQ Low Reference OAQ High Reference IAQ PRE-OCCUPIED PURGE IAQ Purge IAQ Purge Duration IAQ Purge LoTemp Min Pos IAQ Purge HiTemp Min Pos IAQ Purge OAT Lockout DEHUMIDIFICATION CONFIG. Dehumidification Config Dehumidification Sensor Econ disable in DH mode? Vent Reheat Setpt Select Vent Reheat RAT offset Vent Reheat Setpoint Dehumidify Cool Setpoint Dehumidify RH Setpoint CCN CONFIGURATION CCN Address CCN Bus Number CCN Baud Rate CCN BROADCST DEFINITIONS CCN Time/Date Broadcast CCN OAT Broadcast CCN OARH Broadcast CCN OAQ Broadcast Global Schedule Broadcst CCN Broadcast Ack'er CCN SCHEDULES-OVERRIDES Schedule Number Accept Global Holidays? Override Time Limit Timed Override Hours SPT Override Enabled ? T58 Override Enabled ? Global Sched. Override ? ALERT LIMIT CONFIG. SPT lo alert limit/occ SPT hi alert limit/occ SPT lo alert limit/unocc SPT hi alert limit/unocc EDT lo alert limit/occ EDT hi alert limit/occ EDT lo alert limit/unocc EDT hi alert limit/unocc RAT lo alert limit/occ RAT hi alert limit/occ RAT lo alert limit/unocc RAT hi alert limit/unocc RARH low alert limit RARH high alert limit SP low alert limit SP high alert limit BP lo alert limit BP high alert limit IAQ high alert limit SENSOR TRIM CONFIG. Air Temp Lvg SF Trim RAT Trim OAT Trim SPT Trim Cir A Sat.Cond.Temp Trim Cir B Sat.Cond.Temp Trim Suct.Press.Circ.A Trim Suct.Press.Circ.B Trim Dis.Press.Circ.A Trim Dis.Press.Circ.B Trim RANGE 0 - 5000 0 - 5000 0 - 5000 0 - 5000 Yes/No 5-60 min 0-100 % 0-100 % 35-70 dF 0-2(multi-text strings) 1-2(multi-text strings) Yes/No 0-1(multi-text strings) 0-8 ^F 55-95 dF 40-55 dF 10-90 % 1 - 239 0 - 239 1 - 5 (multi-text strings) ENTRY 0 2000 0 2000 No 15 10 35 50 0 1 Yes 0 0 70 45 55 1 0 3 ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF On Off Off Off Off Off 0 - 99 YES/NO 0 - 4 HRS 0 - 4 HRS YES/NO YES/NO YES/NO 1 No 1 0 Yes Yes No –10-245 dF –10-245 dF –10-245 dF –10-245 dF –40-245 dF –40-245 dF –40-245 dF –40-245 dF –40-245 dF –40-245 dF –40-245 dF –40-245 dF 0-100 % 0-100 % 0-5 "H2O 0-5 "H2O –0.25-0.25 "H2O –0.25-0.25 "H2O 0-5000 –10 - 10 ^F –10 - 10 ^F –10 - 10 ^F –10 - 10 ^F –30 - 30 ^F –30 - 30 ^F –50 - 50 PSIG –50 - 50 PSIG –50 - 50 PSIG –50 - 50 PSIG CL-4 DEFAULT 60 85 45 100 40 100 40 100 60 90 40 100 0 100 0 2 -0.25 0.25 1200 0 0 0 0 0 0 0 0 0 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE ITEM AQ.S.RIQ.R.L AQ.S.RIQ.R.H AQ.S.ROQ.R.L AQ.S.ROQ.R.H IAQ.P IAQ.PIQ.PG IAQ.PIQ.P.T IAQ.PIQ.P.L IAQ.PIQ.P.H IAQ.PIQ.L.O ITEM SW.LG FTS.L IGC.L RMI.L ECS.L SFS.L DL1.L DL2.L IAQ.L FSD.L PRS.L EVC.L PRG.L DISP TEST METR LANG PAS.E PASS EXPANSION SWITCH LOGIC: NO / NC Filter Status Inpt-Clean IGC Feedback - Off RemSw Off-Unoc-Strt-NoOv Economizer Switch - No Fan Status Sw. - Off Dmd.Lmt.Sw.1 - Off Dmd.Lmt.-Dehumid - Off IAQ Disc.Input - Low Fire Shutdown - Off Pressurization Sw. - Off Evacuation Sw. - Off Smoke Purge Sw. - Off DISPLAY CONFIGURATION Test Display LEDs Metric Display Language Selection Password Enable Service Password RANGE Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close ON/OFF ON/OFF 0-1(multi-text strings) ENABLE/DISABLE 0000-9999 CL-5 DEFAULT Open Open Open Open Open Open Open Open Open Open Open Open Off Off 0 Enable 1111 ENTRY MODEL NO.: _________________________________ SERIAL NO.: ______________________________________ SOFTWARE VERSION _________________________ TECHNICIAN: ____________________________________ DATE: _______________________________________ PRE-START-UP: VERIFY THAT DIP SWITCH SETTINGS ARE CORRECT VERIFY THAT ALL PACKING MATERIALS HAVE BEEN REMOVED FROM UNIT REMOVE ALL COMPRESSOR SHIPPING HOLDDOWN BOLTS AND BRACKETS PER INSTRUCTIONS VERIFY INSTALLATION OF ECONOMIZER HOOD VERIFY INSTALLATION OF ALL OPTIONS AND ACCESSORIES VERIFY THAT ALL ELECTRICAL CONNECTIONS AND TERMINALS ARE TIGHT CHECK GAS PIPING FOR LEAKS (48A ONLY) CHECK THAT RETURN-AIR FILTER AND OUTDOOR-AIR FILTERS ARE CLEAN AND IN PLACE VERIFY THAT UNIT IS LEVEL WITHIN TOLERANCES FOR PROPER CONDENSATE DRAINAGE CHECK FAN WHEELS AND PROPELLERS FOR LOCATION IN HOUSING/ORIFICE, AND SETSCREW IS TIGHT VERIFY THAT FAN SHEAVES ARE ALIGNED AND BELTS ARE PROPERLY TENSIONED VERIFY THAT SUCTION, DISCHARGE, AND LIQUID SERVICE VALVES ON EACH CIRCUIT ARE OPEN VERIFY THAT CRANKCASE HEATERS HAVE BEEN ON 24 HOURS BEFORE START-UP START-UP: ELECTRICAL SUPPLY VOLTAGE L1-L2 __________ __________ L3-L1 __________ COMPRESSOR AMPS — COMPRESSOR NO. 1 L1 __________ L2 __________ L3 _________ COMPRESSOR AMPS — COMPRESSOR NO. 2 L1 __________ L2 __________ L3 _________ SUPPLY FANS AMPS EXHAUST FAN AMPS __________ (CV) ________ (VAV) ________ * L2-L3 *VAV fan supply amps reading must be taken with a true RMS meter for accurate readings. TEMPERATURES OUTDOOR-AIR TEMPERATURE __________ F DB (Dry Bulb) RETURN-AIR TEMPERATURE __________ F DB __________ F WB (Wet Bulb) COOLING SUPPLY AIR __________ F GAS HEAT SUPPLY AIR __________ F (48A ONLY) ELECTRIC HEAT SUPPLY AIR __________ F (50A ONLY, IF EQUIPPED) PRESSURES GAS INLET PRESSURE __________ IN. WG (48A ONLY) GAS MANIFOLD PRESSURE STAGE NO. 1 __________ IN. WG STAGE NO. 2 __________IN. WG (48A ONLY) REFRIGERANT SUCTION CIRCUIT NO. 1 __________ PSIG CIRCUIT NO. 2__________ PSIG REFRIGERANT DISCHARGE CIRCUIT NO. 2 __________ PSIG CIRCUIT NO. 2__________ PSIG VERIFY REFRIGERANT CHARGE. Copyright 2010 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480077-01 Printed in U.S.A. Form 48/50A-9T Pg CL-6 6-10 Replaces: 48/50A-7T - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE UNIT START-UP CHECKLIST
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Title : 48_50a-9t.fm Creator : msdt05k Create Date : 2010:06:08 10:57:40-04:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2010:06:08 10:57:40-04:00 Producer : Acrobat Distiller 9.2.0 (Windows) Document ID : uuid:774c7deb-554a-4801-aac6-3960ea8100de Instance ID : uuid:61f10a86-076d-48cb-8da5-0201c5628b41 Page Count : 190 Author : msdt05kEXIF Metadata provided by EXIF.tools