Casio Computer DQR300K-1 433MHz RF Thermo & Hygro Receiver User Manual eg DQR300 5

Casio Computer Co Ltd 433MHz RF Thermo & Hygro Receiver eg DQR300 5

User Manual

User's  GuideGuida dell’utilizzatoreDQR-300K(DTX-1010 : SUB-UNIT)MAX/MINTEMPTIME ZONEDSTMAX/MINHUMIDITYSETWAVERE-SYNCSELECTRESETCLEARSNZONOFFALMMAX/MINTEMPMAX/MINHUMIDITYSET-+WAVERE-SYNCSELECTRESETCLEARSNZONOFFALMRESETSELECTIONRESETSELECTIONRESETSELECTION℃/°FRESETSELECTION ℃/°FENGLISHA sticker is affixed to the glass of this clock when you purchase it. Be sure to remove the sticker before using theclock. Depending on the clock model, the configuration of your clock may differ somewhat from that shown in theillustration.Alarm Off Alarm OnOPERATING PRECAUTIONSDo not use or store this clock in areas exposed to temperature extremes, strong magnetism, strong vibration, orstrong impact.Heat can shorten battery life and cause malfunction. Keep the clock away from heaters and direct sunlight whenusing it.Never use the clock in a bathroom or any other area subject to high humidity.Never try to take the clock apart. Doing so can cause malfunction.To clean the clock, use a soft, dry cloth or a cloth moistened in a solution of water and a mild neutral detergent.Wring out all excess moisture from the cloth. Never use thinner, benzene, alcohol or other similar agents.Keep your manual and all information handy for future reference.  This product is warranted to be free of defects in manufacturing for 1 year after purchase. Defective clock should be  returned to the place of retail purchase.Warning : Changes or modifications to this unit not expressly approved by the party responsible for compliance could                void the user's authority to operate the equipment.LIABILITY DISCLAIMER :  The manufacturer and supplier cannot accept any responsibility for any incorrect readings and consequences that occar should an inaccurate reading take place.  This product is not to be used for medical purposes or for public information.  The specifications of the product may change without prior notice.  This product is not a toy. Keep out of the reach of children.  No part of this manual may be reproduced without written authorization of the manufacture.Customer Service Dept.Equity Industries Corp5721 Bayside RoadVirginia Beach, VA 23455 U.S.AUSING THE CLOCKAny of the following procedures can be used to set current date and time.Auto receive of the time calibration signalManual receive of the time calibration signalManual setting without using the time calibration signalAuto ReceiveThe clock receives the time calibration signal eight time each day (2:00, 5:00, 8:00, 11:00, 14:00, 17:00, 20:00,23:00).A signal receive operation takes from two to ten minutes under good signal conditions.A receive indicator shows the current status of the receive operation.Antenna IconReceive in progress: Icon flashesReceive failed: Icon not displayedReceive successful: Icon displayedWAVE OK IndicatorReceive in Progress: OK not displayedAll receives over the past 24 hours failed:  OK not displayedAt least one successful receive over the past 24 hours: OK displayedUnsuccessful Signal ReceptionThe antenna icon disappears from the display when a signal receive operation is unsuccessful. If this happens, trychanging the position or orientation of the clock, and press the WAVE button () to receive again.The time calibration signal includes both Standard Time and Daylight Saving Time (summer time) data.Important!Do not perform any button or switch operation while a signal receive operation is in progress.Manual ReceivePress the WAVE button () to start a calibration signal receive operation.Use the WAVE button () to perform a receive operation after replacing the clock’s batteries or if the autoreceive operation was not performed correctly for some reason.The clock beeps and display illumination flashes for about three seconds when a receive operation trigged by theWAVE button () is successful.Setting the Time and Date ManuallyWhen using the clock that is outside of the range of the transmitters in Fort Collins or in an area where signalreception is impossible for some reason, you need to manually adjust the time as required.1. Press the SET button () to cycle through the setting screens as shown below.2. While the screen you want is on the display,use the Alarm Time Set buttons  () to change the digits that areflashing.+Press   to decrease the flashing digits.Press + to increase the flashing digits.Holding down + or -  changes the flashing digits at high speed.You can set the year in the range of 2000 to 2039. The day of the week is set automatically in accordance withthe date setting.Pressing + or -  while the Time Setting Screen is on the display causes the seconds count to be reset to 00.Each press of + or -  while the 12-hour/24-hour Timekeeping Screen is on the display toggles between 12-hourand 24-hour timekeeping.3. After making the settings you want, use the SET button ()  to display the Normal Timekeeping Screen.The clock automatically returns to the Normal Timekeeping Screen if you leave a setting screen on the display forabout three minutes without performing any operation.USING THE ALARMThe alarm sounds and the backlight turns on when the alarm time you set is reached. You can also use the AlarmMode selector () to select the snooze alarm feature.Setting the Alarm TimeUse the Alarm Time Set buttons ( )  to set the alarm time.Pressing the Alarm Time Set buttons  () causes the alarm time to appear in place of the date on the display.+Press to change the alarm time setting ( )Press to change the alarm time setting (+)Holding down + or -  changes the digits at high speed.Turning the Alarm On and OffUse the Alarm Mode selector  ( ) on the side of the clock to turn the alarm on and off, and to select the snoozefeature.The alarm time appears in place of the date on the display whenever the Alarm Mode selector(⑤) is set to ON or SNOOZE.The backlight also turns on for the first four seconds that the alarm sounds.The alarm sound changes over four levels as it sounds.Stopping the AlarmWhen alarm is sounding, press the LIGHT/SNOOZE button  () to stop it. When the snooze feature is turnedon, the alarm will sound again in about five minutes.To turn off the snooze feature, slide the Alarm Mode selector  () to OFF.USING THE LIGHTBATTERY REPLACEMENTMAIN UNIT/SUB UNIT COMMUNICATION PRECAUTIONSPressing the LIGHT button () turns on the light and illuminates the display for easy reading in the dark.Important!Overuse of the light can shorten battery life.To replace main unit batteriesReplace batteries whenever the following :  When RF communication cannot be successful.  When RCC cannot receive.  When backlight cannot be lid.  When LCD dimmed.  When sound low.1. Open the battery compartment cover as shown in the illustration.2. Remove all of the old batteries.3. Load full set of new batteries. Make sure that their positive (+) and negative (-) ends face in the correct     directions. If you load batteries incorrectly, they can burst and damage the clock.4. Replace the battery compartment cover.5. Press the RESET button (⑥). Be sure to press the RESET button (⑥) after replacing batteries.  To replace sub-unit batteriesReplace batteries whenever the following :  When RF communication cannot be successful.  When LCD dimmed.1. Open the stand so you can see the back cover.2. Remove the back cover screw, and then open the back cover.3. Remove both old batteries.4. Load full set of new batteries. Make sure that their positive (+) and negative (-) ends face in the correct     directions.If you load batteries incorrectly, they can burst and damage the product.5. Replace the back cover and secure it in place with the screw.6. Press the RESET button  (⑮). Be sure to press the RESET button (⑮) after replacing batteries.7. Press the RE-SYNC button (⑪).THERMOMETER FUNCTIONSBoth the main unit and the sub-unit are equipped with their own temperature sensors. Temperature data measuredby the sub-unit is sent by wireless transfer to the main unit. You can toggle the main unit display between the mainunit temperature reading and the sub-unit temperature reading. This make it possible to view both the indoor andoutdoor temperature on the main unit display.Temperature MeasurementsBoth the main unit and the sub-unit take temperature measurements every 16 seconds.The temperature display shows LO for temperatures below  - 58 ¡F (-50¡C) and  HI  for temperatures above158¡F (70 ¡C).Though temperature readings are displayed up to 32¡F(0 ¡C).and greater than105¡C (41¡F), note that suchreadings are actually outside the guaranteed temperature range of this clock.Switching between Celsius and FahrenheitPush the  ¡C / ¡F button¡C / ¡F button  () to select either Fahrenheit (¡F) or Celsius (¡C). Celsius (¡C)Fahrenheit (¡F) ()¡C¡FSwitching between Main Unit and Sub-unit Temperature DataPress the SELECT button () to toggle the display between the main unit (INDOOR) temperature and the sub-unit (OUTDOOR) temperature.Main unit temperature:  INDOOR indicator displayedSub-unit temperature:  OUTDOOR indicator displayedThe display does not change to the sub-unit (OUTDOOR) temperature if no data has been received from the sub-unit yet.Holding down the SELECT button( )for about two seconds turns on auto display switching (    displayed),which causes the temperature display to alternate between the main unit temperature and sub-unit temperature at five-second intervals. To turn off auto display switching (     not displayed), hold down the SELECT button (⑫)for about two seconds again.Main unit Sub-unitSELECT button ( )INDOOR OUTDOORHigh Temperature and Low Temperature MemoryThe following data is stored in memory automatically.Main unit high temperature and low temperatureSub-unit high temperature and low temperature.To clear the high temperature and low temperature data memory, press the CLEAR button(⑨).New data starts to be stored after memory is cleared.HYGROMETER FUNCTIONSBoth the main unit and the sub-unit are equipped with their own humidity sensors. Humidity data measured by thesub-unit is sent by wireless transfer to the main unit. You can toggle the main unit display between the main unithumidity reading and the sub-unit humidity reading. This make it possible to view both the indoor and outdoorhumidity on the main unit display.Humidity MeasurementsBoth the main unit and the sub-unit take humidity measurements every 16 seconds.The humidity display shows  LO  for humidity below 10% and “HI” for humidity above 90%.Switching between Main Unit and Sub-unit Humidity DataPress the SELECT button () to toggle the display between the main unit (INDOOR) humidity and the sub-unit(OUTDOOR) humidity .Main unit humidity:  INDOOR indicator displayedSub-unit humidity:  OUTDOOR indicator displayedThe display does not change to the sub-unit (OUTDOOR) humidity if no data has been received from the sub-unityet.Holding down the SELECT button( )for about two seconds turns on auto display switching (    displayed),which causes the humidity display to alternate between the main unit humidity and sub-unit humidity at five-second intervals. To turn off auto display switching (     not displayed), hold down the SELECT button  (⑫) for about two seconds again.  Main unit Sub-unitSELECT button ( )INDOOR OUTDOORHigh Humidity and Low Humidity MemoryThe following data is stored in memory automatically.Main unit high humidity and low humiditySub-unit high humidity and low humidityTo clear the high humidity and low humidity data memory, press the CLEAR button  ().New data starts to be stored after memory is cleared.USING THE SUB-UNITData Transfer from the Sub-unitData is transferred from the sub-unit to the main unit every three minutes.The sub-unit is able to send data to the main unit up to an unobstructed distance of about 30 meters.The data receive status is indicated on the display of the main unit by the icons shown below.Receive successful Receive unsuccessfulIf a receive operation is not successful for some reason, the display of the main unit shows dashes (-) in place of the sub-unit temperature and humidity values. If you experience problems with data transfer, press the RE-SYNC button (⑪) to synchronize the two units.Ifthis does not eliminate the problem,try changing the positions or orientations of the main unit and sub-unit.The transferred data includes temperature and humidity data. Switching between Celsius and FahrenheitPush the  ¡C / ¡F button () to select either Fahrenheit (¡F) or Celsius (¡C). Celsius (¡C)Fahrenheit (¡F) ¡C / ¡F button ()Switching between Current Temperature and HumidityPress the SELECTION button () to toggle the display between the current temperature and current humidityHolding down SELECTION button () for about two seconds causes the display to continually toggle betweenthe temperature and humidity at five-second intervals. Temperature HumiditySELECTION button ( )LocationPlace the sub-unit in a location where it will not be exposed directly to rain or other elements.USING THE WEATHER FORECAST FEATUREA built in pressure sensor makes it possible to forecast upcoming weather over the next 12 hours based on changesin barometric pressure. Note that these forecast are not absolutely accurate, and are intended for generalreference only.Weather ForecastsBarometric pressure readings are taken every 15 minutes. Weather forecast are based on the last sixreadings. Upcoming weather forecasts are displayed using the graphic indicators shown below. Sunny Sunny, some clouds CloudyRain StormyUpcoming weather trends are indicated as shown below. Improving weather Deteriorating weather Stable weatherWARRANTY CLEAR button ( ) CLEAR button ( )Alarm Mode selectorSNZALARM ON()ALM OFFDescriptionThe alarm sounds at the preset time for one minute, and seven moretimes every five minutes thereafter. Even if you stop the alarm soundby pressing the LIGHT/SNOOZE button (①), the alarm operation isperformed again five minutes later.The indicator (      ) flashes on the display to indicate that thesnooze feature is activated. The alarm sounds at the preset time for one minute.The alarm does not sound.Current temperature and humidityMAX/MIN HUMIDITY button ( )Main unit high humidity and low humiditySub-unit high humidity and low humidityAlarm onindicatorCASIO COMPUTER CO., LTD.6-2, Hon-machi 1-c homeS hibuya-ku, Tokyo 151-8543, J apanPrinted in ChinaETL0501-AMAX/MIN TEMP button (  )Main unit high temperature and low temperatureSub-unit high temperature and low temperatureGENERAL GUIDEMain unit①SNOOZE/LIGHT button  Press this button to illuminate the display for about three seconds.  Pressing this button while the alarm is sounding stops the alarm.②AlarmTime Set buttonsUse these buttons to change the alarm time or current time setting.③SET buttonUse this button when setting the current time.④WAVE buttonPress this button to receive the time calibration signal and adjust timekeeping.⑤Alarm Mode selectorSNZ: Snooze alarm onON: Alarm onOFF: Alarm off⑥RESET buttonPress this button to reset the clock after replacing its batteries.⑦MAX/MIN TEMP. buttonPress this button to display the high and low temperature values.⑧MAX/MIN HUMIDITY buttonPress this button to display the high and low humidity values.⑨CLEAR buttonPress this button to clear the currently displayed high/low temperature or humidity.⑩℃/゜ Press this button to toggle the temperature units between Celsius and Fahrenheit.⑪RE-SYNC buttonPress this button to re-synchronize the timing of the main unit and the sub-unit.⑫SELECT buttonPress this button to toggle the display between main unit (INDOOR) and sub-unit (OUTDOOR) data.⑬DST/TIME ZONE button  Press this button to select the appropriate time zone.  Press this button to toggle between dst on and dst off.Sub-unit⑭SELECTION buttonPress this button to toggle the display between the current temperature and humidity.⑮RESET buttonPress this button to reset the sub-unit after replacing its batteries.⑯TEST buttonThis button is for testing the unit. Normally, you should not press it. If you do, be sure to press the RESET button(⑮)next.⑰℃/゜ Press this button to toggle the temperature units between Celsius and Fahrenheit.Main unitSub-unitPM indicatorWAVE OK indicatorAntenna IconCurrent HumidityUpcomimg weatherindicatorCurrent time(Hour, minutes, second) Day of the weekDATE (month - date)Current TemperatureSnooze on indicatorAlarm timeInside, amongbuildings, or nearneon signsInside a vehicle Near refrigeratorsor other householdappliances, nearoffice equipment,mobile phones orwireless LANdevices.Near aconstruction site,airport, or othersources ofelectrical  noise,underground or intunnels, nearrailroads,highways, or radiostations withinterferingfrequencies.Near high-tensionpower linesAmong or behindmountainsNormal Timekeeping ScreenYear Setting Screen 12-hour/24-hour Timekeeping ScreenMonth and Day Setting Screen Time Setting ScreenTIME CALIBRATION SIGNAL RECEPTION PRECAUTIONSWith the Radio-Controlled Clock, you have the most accurate timepiece within the continent. It can receive the time signal transmitted by the National Institute of Standards and Technology (NIST), which is regulated by 3 atomic clocks and deviates less than 1 second within 3,000 years.The NIST broadcasts the time signal (WWVB, 60kHz) continuously from Fort Collins, Colorado. This signal can be received anywhere in the continental USA that long wave (AM) radio reception is possible with a portable radio. It is expected that the signal can reach a distance of  2,000 miles from the transmitter. Therefore, your clock will receive  the signal within the broadcast range anywhere an AM signal can be received; generally the signal cannot be picked up in massive metal and concrete structures unless near a window. In addition, some environmental effects (see below) may affect the transmitting distance.Signal reception is normally better at night than during the day.Radio interference can make signal reception impossible.Strong electrostatic charge can result in the wrong time being set.If you are in an area where proper time calibration signal reception is impossible, the clock keeps time with theprecision noted in "SPECIFICATIONS".For more information, please study the WWVB   WEB page of NIST at:http://www.boulder.nist.gov/timefreq/WAORCANVUTIDAZ NMCOWYMT NDSDNEKSOKTXMNMIIAMOARLAWIILTNKYIN OHMS AL GAFLSCNCVAWVPANYMEMARICTNJDEMDNHVTMIEasternStandardTimeCentralStandardTimeMountainStandardTimePacificStandardTimeFort Collins2000 miles1200 milesSetting the Time Zone and Daylight Saving Time1. Press the DST/TIME ZONE button( ) to select the appropriate time zone.2. The unit is default with DST activated. If it is used in regions do not observe DST, please follow the  following procedures to deactivate DST: i.  Hold down the DST/TIME ZONE button( ) for about 4 seconds, the unit will give 3 short beeps with  "DST" and "On" blinking on the LCD display. ii.  Press the + or - button, the display will become "DST" and "Off to indicate DST being deactivated. iii.  Press the DST/TIME ZONE button( )again for normal operation.TIME ZONEDSTF button①⑤⑧③②⑪⑫⑦⑨⑥④⑬F buttonTESTTEST⑰⑭⑮⑯1212④④④④③②③⑤②②⑤①⑤①⑩⑩⑫⑫⑫⑫⑦⑨⑫⑫⑫⑧⑨⑨⑰⑰⑭⑭⑭⑬⑬⑬2TEST¡C / ¡FTEST¡C / ¡FSPECIFICATIONS (Main unit)Signal Receiver : Long-wave (Frequency : 60.0kHz) National Institute of Standard and Technology (NIST) WWVB;       Fort Collins, Accuracy at normal temperature : Within 60 seconds per month when signal reception is not possible.Calendar system : Auto-calendar pre-programmed from the year 2000 to 2039Alarm : Daily Alarm, Snooze Alarm (7 repeats)Thermometer Functions : Measuring range : -58¡F to 158¡F (-50¡C to 70¡C)Temperature Sensor Precision : 4¡F (2¡C) in range of 32¡F to 104¡F (0¡C to 40¡C)Hygrometer Function : Measuring range : 10% to 90%, when temperature is 32¡F to 104¡F (0¡C to 40¡C)Humidity Sensor Precision : 10%, when temperature is 32¡F to 104¡F (0¡C to 40¡C)Weather Forecast Function : Barometric pressure reading at 15-minute intervals; upcoming weather forecasts.Other:  LED light;12/24-hour timekeepingBattery : Four AAA size batteries (Type : LR03)Battery life : Approximately 1 year, 8 time calibration signal reception per day,                       One 1 minutes alarm operation per day2 second light operation per dayOperating temperature:  32¡F to 104¡F (0¡C to 40¡C)SPECIFICATIONS (Sub-unit)RF transmission frequency : 433.92MHzRF transmission range : 30m, unobstructedThermometer Functions : Measuring range : -58¡F to 158¡F (-50¡C to 70¡C)Temperature Sensor Precision : 2¡C (4¡F) in range of 32¡F to 104¡F (0¡C to 40¡C)Hygrometer Function : Measuring range : 10% to 90%, when temperature is 32¡F to 104¡F (0¡C to 40¡C)Humidity Sensor Precision : 10%, when temperature is 32¡F to 104¡F (0¡C to 40¡C)Battery : Two AA size batteries (Type : R6P)Battery life : Approximately 1 yearOperating temperature:  14¡F to 140¡F (-10¡C to 60¡C)Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could                  void the user's authority to operatethe equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to            Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful           interference in a residential installation. This equipment generates, uses and can radiate radio frequency            energy and, if not installed and used in accordance with the instructions, may cause harmful interference to            radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.Under the environment with radio frequency interference, the unit may malfunction and require user to reset the unit.FOR CUSTOMER INQUIRIES :EMAIL :  shelley@eic.hrcoxmail.comWeb : www.skyscaninfo.comTel : 757-460-2483Battery precautions   Keep batteries out of the reach of small children.  If a battery is accidentally swallowed, contact your physician    immediately   Be sure to load the batteries with their positive (+) and negative (-) ends facing correctly.   Never charge the batteries that come with the clock.   Should batteries ever leak while in the clock, wipe out the fluid with a cloth, taking care not to let any get into    your skin.   Replace the batteries at least once a year, even if the current batteries are working properly.   The batteries that come with the clock lose some of their power during transport and storage.UP DOWN(   ) (   )+UP(   )  Certain environmental cinditions can greally reduce the communication range.  Locating the sub-unit near a device that transmits radio signals using the same frequency as this product can  cause communication failure of this product.  Avoid using multiple product in the same area. Doing so can mixing of their signals.

Navigation menu