Casio Sgw300H 1Av Wrist Watch Users Manual QW 3202
SGW300H-1AV to the manual e9a34c9e-5aa8-4e7b-9a52-88b17f49ddca
2015-01-21
: Casio Casio-Casio-Sgw300H-1Av-Wrist-Watch-Sgw300H-1Av-Users-Manual-243981 casio-casio-sgw300h-1av-wrist-watch-sgw300h-1av-users-manual-243981 casio pdf
Open the PDF directly: View PDF .
Page Count: 5
- About This Manual
- Things to check before using the watch
- Mode Reference Guide
- Timekeeping
- Configuring Home City Settings
- Configuring Current Time and Date Settings
- Barometer/Thermometer
- Altimeter
- Specifying Temperature, Barometric Pressure, and Altitude Units
- Precautions Concerning Simultaneous Measurement of Altitude and Temperature
- Checking the Current Time in a Different Time Zone
- Using the Stopwatch
- Using the Countdown Timer
- Using the Alarm
- Illumination
- Button Operation Tone
- Troubleshooting
- Specifications
- City Code Table
Operation Guide 3202
1
Congratulations upon your selection of this CASIO watch.
Applications
The built-in sensors of this watch measure barometric pressure, temperature and
altitude. Measured values are then shown on the display. Such features make this
watch useful when hiking, mountain climbing, or when engaging in other such outdoor
activities.
Warning !
•
The measurement functions built into this watch are not intended for taking
measurements that require professional or industrial precision. Values produced
by this watch should be considered as reasonable representations only.
• Note that CASIO COMPUTER CO., LTD. assumes no responsibility for any
damage or loss suffered by you or any third party arising through the use of
this product or its malfunction.
About This Manual
• Depending on the model of your watch, display text
appears either as dark figures on a light background, or
light figures on a dark background. All sample displays
in this manual are shown using dark figures on a light
background.
• Button operations are indicated using the letters shown
in the illustration.
• Note that the product illustrations in this manual are
intended for reference only, and so the actual product
may appear somewhat different than depicted by an
illustration.
Things to check before using the watch
1. Check the Home City and the daylight saving time (DST) setting.
Use the procedure under “To configure Home City settings” to configure your Home
City and daylight saving time settings.
Important!
Proper World Time Mode data depend on correct Home City, time, and date settings
in the Timekeeping Mode. Make sure you configure these settings correctly.
2. Set the current time.
See “Configuring Current Time and Date Settings”.
The watch is now ready for use.
Mode Reference Guide
Your watch has 7 “modes”. The mode you should select depends on what you want to do.
To do this: Enter this mode:
• View the current time and date in the Home City
•
Configure Home City and daylight saving time (DST) settings
• Configure time and date settings
Timekeeping Mode
View the barometric pressure and temperature at your
current location
Barometer/Thermometer
Mode
• View the altitude at your current location
• Determine the altitude differential between two locations
(reference point and current location)
Altimeter Mode
View the current time in one of 48 cities (31 time zones)
around the globe World Time Mode
Use the stopwatch to measure elapsed time Stopwatch Mode
Use the countdown timer Countdown Timer Mode
Set an alarm time Alarm Mode
MO1004-EB
Selecting a Mode
• The illustration below shows which buttons you need to press to navigate between
modes.
• In any mode (except when a setting screen, with flashing digits is on the display),
press B to illuminate the display.
World Time
Mode
Barometer/
Thermometer Mode
Stopwatch Mode
Countdown
Timer Mode Alarm Mode
Altimeter Mode
Timekeeping Mode
World Time
Mode
Barometer/
Thermometer Mode
Stopwatch Mode
Countdown
Timer Mode Alarm Mode
Altimeter Mode
Timekeeping Mode
General Functions (All Modes)
The functions and operations described in this section can be used in all of the modes.
Auto Return Features
• The watch returns to the Timekeeping Mode automatically if you do not perform any
button operation for two or three minutes in the Alarm Mode.
• The watch will return to the Timekeeping Mode automatically if you do not perform
any operation for about one hour after entering the Barometer/Thermometer Mode.
•
If you leave a setting screen with flashing digits on the display for two or three minutes
without performing any operation, the watch exits the setting screen automatically.
Initial Screens
When you enter the World Time Mode or Alarm Mode, the data you were viewing
when you last exited the mode appears first.
Scrolling
The B and D buttons are used on the setting screen to scroll through data on the
display. In most cases, holding down these buttons during a scroll operation scrolls
through the data at high speed.
Timekeeping
Use the Timekeeping Mode to set and view the current
time and date.
• In the Timekeeping Mode, the graphic in the center of
the display indicates the passage of seconds.
PM
indicator
Day of
week
Month
Day
Seconds
Graphi
c
Hour : Minutes
PM
indicator
Day of
week
Month
Day
Seconds
Graphi
c
Hour : Minutes
Configuring Home City Settings
There are two Home City settings: actually selecting the Home City and selecting
either standard time or daylight saving time (DST).
To configure Home City settings
1. In the Timekeeping Mode, hold down A until the
currently selected city code (Home City) starts to flash.
This is the city code setting screen.
• Before the city code starts to flash, the message
SET Hold will appear on the display. Keep A
depressed until SET Hold disappears and the city
code starts to flash.
• The watch will exit the setting mode automatically if
you do not perform any operation for about two or
three minutes.
• For details about city codes, see the “City Code
Table”.
2. Press D (East) and B (West) to select the city code
you want to use as your Home City.
• Keep pressing D or B until the city code you want
to select as your Home City appears on the display.
3. Press C to display the DST setting screen.
4.
Press
D
to toggle between Daylight Saving Time (On)
and Standard Time (OFF).
• Note that you cannot switch between standard
time and daylight saving time (DST) while UTC is
selected as your Home City.
5.
After all the settings are the way you want, press A to return to the Timekeeping Mode.
• The DST indicator appears to indicate that Daylight Saving Time is turned on.
Note
• After you specify a city code, the watch will use UTC* offsets in the World Time
Mode to calculate the current time for other time zones based on the current
time in your Home City.
* Coordinated Universal Time, the world-wide scientific standard of timekeeping.
The reference point for UTC is Greenwich, England.
PM
indicator
City
code
Second
s
Hour : Minutes
PM
indicator
City
code
Second
s
Hour : Minutes
Setting
DST indicator
Setting
DST indicator
Operation Guide 3202
2
To change the Daylight Saving Time (summer time) setting
1. In the Timekeeping Mode, hold down A until the
currently selected city code (Home City) starts to flash.
This is the city code setting screen.
• Before the city code starts to flash, the message
SET Hold will appear on the display. Keep A
depressed until SET Hold disappears and the city
code starts to flash.
2. Press C to display the DST setting screen.
3. Press D to toggle between Daylight Saving Time (On)
and Standard Time (OFF).
4. After all the settings are the way you want, press A to
return to the Timekeeping Mode.
• The DST indicator appears to indicate that Daylight
Saving Time is turned on.
Configuring Current Time and Date Settings
You can use the procedure below to adjust the current time and date settings if they
are off.
To change the current time and date settings
1. In the Timekeeping Mode, hold down A until the
currently selected city code (Home City) starts to flash.
This is the city code setting screen.
• Before the city code starts to flash, the message
SET Hold will appear on the display. Keep A
depressed until SET Hold disappears and the city
code starts to flash.
2. Use D and B to select the city code you want.
• Select your Home City code before changing any
other setting.
• For full information on city codes, see the “City
Code Table”.
3.
Press C to move the flashing in the sequence shown below to select the other settings.
Barometer
unit
Temperature
unit
Illumination
Duration
Button Operation
Tone On/Off Day
City
Code DST
Altitude
unit
12/24-Hour
Format Seconds Hour Minute Year Month
• The following steps explain how to configure timekeeping settings only.
4. When the timekeeping setting you want to change is flashing, use B and/or D to
change it as described below.
Screen To do this: Do this:
Change the city code Use D (East) and
B (West).
Toggle between Daylight Saving Time (On)
and Standard Time (OFF). Press D.
Toggle between 12-hour (12H) and 24-hour
(24H) timekeeping. Press D.
50 Reset the seconds to 00 Press D.
Change the hour or minute
Use D (+) and B
(–).
Change the year, month, or day
5. Press A to exit the setting screen.
Note
• For information about selecting a Home City and configuring the DST setting, see
“Configuring Home City Settings”.
• While 12-hour format is selected for timekeeping, a P (PM) indicator will appear for
times from noon to 11:59 p.m. No indicator appears for times from midnight to
11:59 a.m. With 24-hour format, time is displayed from 0:00 to 23:59, without any P
(PM) indicator.
• The watch’s built-in full automatic calendar makes allowances for different month
lengths and leap years. Once you set the date, there should be no reason to
change it except after you have the watch’s battery replaced.
Barometer/Thermometer
This watch uses a pressure sensor to measure air pressure (barometric pressure) and
a temperature sensor to measure temperature.
To enter and exit the Barometer/Thermometer Mode
1. While in the Timekeeping Mode, press C to enter the
Barometer/Thermometer Mode.
•BARO will appear on the display, indicating
that barometric pressure and temperature
measurements are in progress. The measurement
results will appear on the display after about five
seconds.
• After you press C, the watch will take readings
every five seconds for the first three minutes, and
then every two minutes after that.
2. Press C five times to return to the Timekeeping Mode.
•
The watch will return to the Timekeeping Mode automatically if you do not perform
any operation for about one hour after entering the Barometer/Thermometer Mode.
Barometric Pressure
• Barometric pressure is displayed in units of 1 hPa (or 0.05 inHg).
•
The displayed barometric pressure value changes to - - - if a measured barometric
pressure falls outside the range of 260 hPa to 1,100 hPa (7.65 inHg to 32.45 inHg).
The barometric pressure value will reappear as soon as the measured barometric
pressure is within the allowable range.
Setting
DST indicator
Setting
DST indicator
PM
indicator
Second
s
Hour : Minutes
City
code
PM
indicator
Second
s
Hour : Minutes
City
code
Temperature
Current time
Barometric
pressure
Pressure
differential
pointer
Temperature
Current time
Barometric
pressure
Pressure
differential
pointer
Temperature
• Temperature is displayed in units of 0.1°C (or 0.2°F).
• The displayed temperature value changes to --.- °C (or °F) if a measured
temperature falls outside the range of –10.0°C to 60.0°C (14.0°F to 140.0°F). The
temperature value will reappear as soon as the measured temperature is within the
allowable range.
Display Units
You can select either hectopascals (hPa) or inchesHg (inHg) as the display unit for the
measured barometric pressure, and Celsius (°C) or Fahrenheit (°F) as the display unit
for the measured temperature value. See “To specify temperature, barometric
pressure, and altitude units”.
Barometric Pressure Differential Pointer
This pointer indicates the relative difference between
the most recent barometric pressure reading and the
current barometric pressure value displayed in the
Barometer/Thermometer Mode.
Reading Barometric Pressure Differential Pointer
Pressure differential is indicated in the
range of ±5 hPa, in 1-hPa units.
If the pointer is
located here: It means this:
CLOUDY (–)
Pressure is falling and
weather will tend to
deteriorate.
FINE (+)
Pressure is rising and
weather will tend to
improve.
• The nearby screen shot, for example,
shows what the pointer would indicate
when the calculated pressure
differential is approximately – 3 hPa
(approximately – 0.09 inHg).
• Barometric pressure is calculated and displayed using hPa as the standard. The
barometric pressure differential also can be read in inHg units as shown in the
illustration (1 hPa = 0.03 inHg).
Pressure Sensor and Temperature Sensor Calibration
The pressure sensor and temperature sensor built into the watch are calibrated at the
factory and normally require no further adjustment. If you notice serious errors in the
pressure readings and temperature readings produced by the watch, you can calibrate
a sensor to the reading of another device to correct the errors.
Important!
• Incorrectly calibrating the temperature sensor can result in incorrect readings.
Carefully read the following before doing anything.
–
Compare the readings produced by the watch with those of another reliable and
accurate thermometer.
– If adjustment is required, remove the watch from your wrist and wait for 20 or 30
minutes to give the temperature of the watch time to stabilize.
To calibrate the pressure sensor and the temperature sensor
1.Take a reading with another measurement device to
determine the exact current barometric pressure or
temperature.
2. With the watch in the Timekeeping Mode, press C to
enter the Barometer/Thermometer Mode.
3. Hold down A until the current temperature value starts
to flash on the display. This is the setting screen.
• Before the temperature value starts to flash, the
message SET Hold will appear on the display.
Keep A depressed until SET Hold disappears.
4. Press C to move the flashing between the temperature
value and barometric pressure value, to select the one
you want to calibrate.
5.
Use D (+) and B (–) to adjust the calibration value in the units shown below.
Temperature 0.1°C (0.2°F)
Barometric Pressure 1 hPa (0.05 inHg)
• To return the currently flashing value to its initial factory default setting, press
B and D at the same time. OFF will appear at the flashing location for about
one second, followed by the initial default value.
6. Press A to return to the Barometer/Thermometer Mode screen.
Barometer and Thermometer Precautions
• The pressure sensor built into this watch measures changes in air pressure, which
you can then apply to your own weather predictions. It is not intended for use as a
precision instrument in official weather prediction or reporting applications.
• Sudden temperature changes can affect pressure sensor readings.
• Temperature measurements are affected by your body temperature (while you are
wearing the watch), direct sunlight, and moisture. To achieve a more accurate
temperature measurement, remove the watch from your wrist, place it in a well
ventilated location out of direct sunlight, and wipe all moisture from the case. It
takes approximately 20 to 30 minutes for the case of the watch to reach the actual
surrounding temperature.
Altimeter
The watch displays altitude values based on air pressure readings taken by a built-in
pressure sensor.
How the Altimeter Measures Altitude
The altimeter can measure altitude based on its own preset values (initial default
method) or using a reference altitude specified by you.
When you measure altitude based on preset values
Data produced by the watch’s barometric pressure sensor is converted to approximate
altitude based on ISA (International Standard Atmosphere) conversion values stored
in watch memory.
When you measure altitude using a reference altitude specified by you
After you specify a reference altitude, the watch uses
that value to convert barometric pressure readings to
altitude.
Barometric
pressure
differential
pointer
Barometric
pressure
differential
pointer
−0.15 0 0.15
−5 0 5
inHg values
hPa values
Current pressure
less than most
recent measured
pressure
Current pressure
greater than most
recent measured
pressure
−0.15 0 0.15
−5 0 5
inHg values
hPa values
Current pressure
less than most
recent measured
pressure
Current pressure
greater than most
recent measured
pressure
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
A
B
A
B
Operation Guide 3202
3
• When mountain climbing, you can specify a reference altitude value in accordance
with a marker along the way or altitude information from a map. After that, the
altitude readings produced by the watch will be more accurate than they would
without a reference altitude value.
To take an altimeter reading
1. Make sure the watch is in the Timekeeping Mode.
2. Press
D
to start Altimeter measurement.
•ALTI will appear on the display, indicating that
Altimeter measurement is in progress. The first
reading will appear on the display after about four
or five seconds.
• The current altitude value is displayed in units of 5
meters (20 feet).
• After the first reading is obtained, the watch
continues to take altimeter readings automatically
every five seconds for the first three minutes, and
then every two minutes after that.
• If you leave the watch in the Altimeter Mode, it will update the displayed altitude
value regularly.
• Temperature is measured in the Barometer/Thermometer Mode and in the
Altimeter Mode. For details about temperature readings, see "Temperature".
3. After you are finished using the Altimeter, press
C
to return to the Timekeeping
Mode and stop auto measurement.
• The watch will return to the Timekeeping Mode automatically if you do not
perform any operation for about 10 hours after entering the Altimeter Mode.
Note
• The measurement range for altitude is –700 to 10,000 meters (–2,300 to 32,800
feet).
• The displayed altitude value changes to - - - - if an altitude reading falls outside the
measurement range. An altitude value will reappear as soon as the altitude reading
is within the allowable range.
•
Normally, displayed altitude values are based on the watch’s preset conversion
values. You also can specify a reference altitude value, if you want. See “Specifying
a Reference Altitude Value” below.
• You can change the unit for displayed altitude values to either meters (m) or feet (ft).
See “To specify temperature, barometric pressure, and altitude units”.
Specifying a Reference Altitude Value
The altitude readings produced by this watch are subject to error caused by changes
in air pressure. Because of this, we recommend that you update the reference altitude
value whenever accurate altitude information is available during your climb. After you
specify a reference altitude value, the watch adjusts its air-pressure-to-altitude
conversion calculation accordingly.
To specify a reference altitude value
1. In the Altimeter Mode, hold down A until the current
reference altitude value starts to flash. This is the
setting screen.
• Before the reference altitude value starts to flash,
the message SET Hold will appear on the display.
Keep A depressed until SET Hold disappears.
2. Press D (+) or B (–) to change the current reference
altitude value by 5 meters (or 20 feet).
• Specify a reference altitude value based on
accurate altitude information about your current
location from a map, etc.
• You can set the reference altitude value within the range of –10,000 to 10,000
meters (–32,800 to 32,800 feet).
•
Pressing B and D at the same time returns to OFF (no reference altitude value),
so the watch performs air pressure to altitude conversions based on preset data
only.
3. Press A to exit the setting screen.
How does the altimeter work?
Generally, air pressure and temperature decrease as altitude increases. This watch
bases its altitude measurements on International Standard Atmosphere (ISA) values
stipulated by the International Civil Aviation Organization (ICAO). These values define
relationships between altitude, air pressure, and temperature.
0 m 500 m
1000 m
1500 m
2000 m
2500 m
3000 m
3500 m
4000 m
899 hPa
795 hPa
701 hPa
616 hPa
8.5°C
2°C
–4.5°C
–11°C
15°C1013 hPa
About 6.5°C
per 1000 m
About 8 hPa per 100 m
About 9 hPa per 100 m
About 10 hPa per 100 m
About 11 hPa per 100 m
About 12 hPa per 100 m
Altitude Air Pressure Temperature
0 ft. 2000 ft.
4000 ft.
6000 ft.
8000 ft.
10000 ft.
12000 ft.
14000 ft.
25.84 inHg
22.23 inHg
19.03 inHg
44.7°F
30.5°F
16.2°F
59.0°F29.92 inHg
About 3.6°F
per 1000 ft.
About 0.15 inHg per 200 ft.
About 0.17 inHg per 200 ft.
About 0.192 inHg per 200 ft.
About 0.21 inHg per 200 ft.
Source: International Civil Aviation Organization
• Note that the following conditions will prevent you from obtaining accurate readings:
When air pressure changes because of changes in the weather
Extreme temperature changes
When the watch itself is subjected to strong impact
There are two standard methods of expressing altitude: Absolute altitude and relative
altitude. Absolute altitude expresses an absolute height above sea level. Relative
altitude expresses the difference between the height of two different places.
Height of building 130 m
(relative altitude)
Rooftop at an altitude of
230 m above sea level
(absolute altitude)
Sea Level
Current time
Current
altitude Temperature
Current time
Current
altitude Temperature
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Altimeter Precautions
• This watch estimates altitude based on air pressure. This means that altitude
readings for the same location may vary if air pressure changes.
• The semiconductor pressure sensor used by the watch for altitude measurements
is also affected by temperature. When taking altitude measurements, do not subject
the watch to temperature changes.
• Do not rely upon this watch for altitude measurements or perform button operations
while sky diving, hang gliding, or paragliding, while riding a gyrocopter, glider, or
any other aircraft, or while engaging in any other activity where there is the chance
of sudden altitude changes.
• Do not use this watch for measuring altitude in applications that demand
professional or industrial level precision.
• Remember that the air inside of a commercial aircraft is pressurized. Because of
this, the readings produced by this watch will not match the altitude readings
announced or indicated the flight crew.
Specifying Temperature, Barometric Pressure, and Altitude Units
Use the procedure below to specify the temperature, barometric pressure, and altitude
units to be used in the Barometer/Thermometer Mode and the Altimeter Mode.
Important!
When TYO (Tokyo) is selected as the Home City, the
altitude unit is set automatically to meters (m), the
barometric pressure unit to hectopascals (hPa), and the
temperature unit to Celsius (°C). These settings cannot
be changed.
To specify temperature, barometric pressure, and altitude units
1. In the Timekeeping Mode, hold down A until the currently selected city code starts
to flash. This is the city code setting screen.
• Before the city code starts to flash, the message SET Hold will appear on
the display. Keep A depressed until SET Hold disappears and the city code
starts to flash.
2. Keep pressing C until TEMP (temperature), ALTI (altitude), or BARO (barometric
pressure) appears in the upper left corner of the screen.
• See step 3 under “To change the current time and date settings” for information
about how to scroll through setting screens.
3. Perform the operations below to specify the units you want.
To specify this unit: Press this key: To toggle between these settings:
Temperature D°C (Celsius) and °F (Fahrenheit)
Altitude Dm (meters) and ft (feet)
Barometric Pressure DhPa (hectopascals) and inHg (inches of mercury)
4. After the settings are the way you want, press A to exit the setting screen.
Precautions Concerning Simultaneous Measurement of Altitude and Temperature
Though you can perform altitude and temperature measurements at the same time,
you should remember that each of these measurements requires different conditions
for best results. With temperature measurement, it is best to remove the watch from
your wrist in order to eliminate the effects of body heat. In the case of altitude
measurement, on the other hand, it is better to leave the watch on your wrist, because
doing so keeps the watch at a constant temperature, which contributes to more
accurate altitude measurements.
• To give altitude measurement priority, leave the watch on your wrist or in any other
location where the temperature of the watch is kept constant.
• To give temperature measurement priority, remove the watch from your wrist and
allow it to hang freely from your bag or in another location where it is not exposed
to direct sunlight. Note that removing the watch from your wrist can affect pressure
sensor readings momentarily.
Checking the Current Time in a Different Time Zone
You can use the World Time Mode to view the current
time in one of 31 time zones (48 cities) around the globe.
The city that is currently selected in the World Time Mode
is called the “World Time City”.
To enter the World Time Mode
Use C to select the World Time Mode (WT) as shown in
“Selecting a Mode”.
•
WT will appear on the display for about one second.
Next, the display will change to show the city code of
the currently selected World Time City.
To view the time in another time zone
In the World Time Mode, use D (East) to scroll through
city codes.
To specify standard time or daylight saving time (DST) for a city
1. In the World Time Mode, use D (East) to display the
city code (time zone) whose Standard Time/Daylight
Saving Time setting you want to change.
2. Hold down A until DST Hold appears on the display
and then disappears. Release A after DST Hold
disappears.
• This toggles the city code you selected in step
1 between Daylight Saving Time (DST indicator
displayed) and standard time (DST indicator not
displayed).
• You cannot use the World Time Mode to change the current standard time/
daylight saving time (DST) setting of the Home City.
• Note that you cannot switch between standard time/daylight saving time
(DST) while UTC is selected as the World Time City.
• Note that the standard time/daylight saving time (DST) setting affects only the
currently selected time zone. Other time zones are not affected.
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Currently selected
World Time City
Current time in the currently
selected World Time City
Current Timekeeping
Mode time
Currently selected
World Time City
Current time in the currently
selected World Time City
Current Timekeeping
Mode time
DST indicatorDST indicator
Operation Guide 3202
4
Using the Stopwatch
The stopwatch measures elapsed time, split times, and two finishes.
To enter the Stopwatch Mode
Use C to select the Stopwatch Mode (STW) as shown in
“Selecting a Mode”.
• STW will appear on the display for about one second.
Next, the display will change to show the stopwatch
hours.
To perform an elapsed time operation
DD D D A
Start Stop (Restart) (Stop) Reset
To pause at a split time
DA A D A
Start Split
(SPL displayed)
Split release
Stop Reset
To measure two finishes
DADAA
Start Split
First runner
finishes.
Display time of
first runner
Stop
Second runner
finishes.
Split release
Display time of
second runner
Reset
Note
• The Stopwatch Mode can indicate elapsed time up to 23 hours, 59 minutes, 59.99
seconds.
• Once started, stopwatch timing continues until you press A to stop it, even if you
exit the Stopwatch Mode to another mode and even if timing reaches the stopwatch
limit defined above.
• Exiting the Stopwatch Mode while a split time is frozen on the display clears the
split time and returns to elapsed time measurement.
Using the Countdown Timer
The countdown timer can be configured to start at a preset time, and sound an alarm
when the end of the countdown is reached.
To enter the Countdown Timer Mode
Use C to select the Countdown Timer Mode (TMR) as
shown in “Selecting a Mode”.
• TMR will appear on the display for about one second.
Next, the display will change to show the countdown
time hours.
To specify the countdown start time
1. Enter the Countdown Timer Mode.
• If a countdown is in progress (indicated by the
seconds counting down), press D to stop it and
then press A to reset to the current countdown
start time.
• If a countdown is paused, press A to reset to the
current countdown start time.
2. Hold down A until the hour setting of the current countdown start time starts to
flash. This is the setting screen.
• Before the hour setting starts to flash, the message SET Hold will appear
on the display. Keep A depressed until SET Hold disappears and the hour
setting starts to flash.
3. Press C to move the flashing between the hour and minute settings.
4. Use D (+) and B (–) to change the flashing item.
• To set the starting value of the countdown time to 24 hours, set 0H 00’00.
5. Press A to exit the setting screen.
To perform a countdown timer operation
DDDDA
Start Stop (Restart) (Stop) Reset
• Before starting a countdown timer operation, check to make sure that a countdown
operation is not already in progress (indicated by the seconds counting down). If it
is, press D to stop it and then A to reset to the countdown start time.
• An alarm sounds for five seconds when the end of the countdown is reached. This
alarm will sound in all modes. The countdown time is reset to its starting value
automatically when the alarm sounds.
To stop the alarm
Press any button.
Using the Alarm
You can set five independent daily alarms. When a daily
alarm is turned on, an alarm tone will sound for about 10
seconds each day when the time in the Timekeeping
Mode reaches the preset alarm time. This is true even if
the watch is not in the Timekeeping Mode.
You can also turn on an Hourly Time Signal, which will
cause the watch to beep twice every hour on the hour.
To enter the Alarm Mode
Use
C
to select the Alarm Mode (ALM) as shown in
“Selecting a Mode”.
• ALM will appear on the display for about one second.
Next, the display will change to show an alarm number
(AL1 through AL5) or the SIG indicator. The alarm
number indicates an alarm screen. SIG is shown when
the Hourly Time Signal screen is on the display.
• When you enter the Alarm Mode, the data you were
viewing when you last exited the mode appears first.
Hours
1/100 second
Second
s
Minutes
Current
time
Hours
1/100 second
Second
s
Minutes
Current
time
Current time
Countdown time
(Hour, minutes,
seconds)
Current time
Countdown time
(Hour, minutes,
seconds)
Alarm
number or
SIG
Alarm time
(Hour : Minutes)
Current time
Alarm
number or
SIG
Alarm time
(Hour : Minutes)
Current time
To set an alarm time
1. In the Alarm Mode, use D to scroll through the alarm
screens until the one whose time you want to set is
displayed.
AL1 AL2 AL3
SIG AL5 AL4
2. Hold down A until the alarm time starts to flash. This is the setting screen.
• Before the alarm time starts to flash, the message SET Hold will appear on
the display. Keep A depressed until SET Hold disappears and the alarm time
starts to flash.
3. Press C to move the flashing between the hour and minute settings.
4. While a setting is flashing, use D (+) and B (–) to change it.
• When setting the alarm time using the 12-hour format, take care to set the time
correctly as a.m. (no indicator) or p.m. (P indicator).
5. Press A to exit the setting screen.
To test the alarm
In the Alarm Mode, hold down D to sound the alarm.
To turn an alarm and the Hourly Time Signal on and off
1. In the Alarm Mode, use D to select an alarm or the Hourly Time Signal.
2. When the alarm or the Hourly Time Signal you want is selected, press A to toggle
it between on and off.
• The alarm on indicator (when any alarm is on) and
the Hourly Time Signal on indicator (when the
Hourly Time Signal is on) are shown on the display
in all modes.
To stop the alarm
Press any button.
Illumination
The display of the watch is illuminated for easy reading in
the dark.
To turn on illumination
In any mode (except when a setting screen is on the
display), press B to illuminate the display.
• You can use the procedure below to select either one
second or three seconds as the illumination duration.
When you press B, the display will remain illuminated
for about one second or three seconds, depending on
the current illumination duration setting.
To change the illumination duration
1. In the Timekeeping Mode, hold down A until the currently selected city code starts
to flash. This is the city code setting screen.
• Before the city code starts to flash, the message SET Hold will appear on the
display. Keep A depressed until SET Hold disappears and the city code
starts to flash.
2. Keep pressing C until LT1 or LT3 is displayed in the upper left corner of the
display.
• See step 3 under “To change the current time and date settings” for
information about how to scroll through setting screens.
3. Press D to toggle the illumination duration between three seconds (LT3 displayed)
and one second (LT1 displayed).
4. After the settings are the way you want, press A to exit the setting screen.
Illumination Precautions
• Illumination may be hard to see when viewed under direct sunlight.
• Illumination turns off automatically whenever an alarm sounds.
• Frequent use of illumination runs down the battery.
Button Operation Tone
The button operation tone sounds any time you press one of the watch’s buttons. You
can turn the button operation tone on or off as desired.
• Even if you turn off the button operation tone, the alarm, Hourly Time Signal, and
Countdown Timer Mode alarm all operate normally.
To turn the button operation tone on and off
1. In the Timekeeping Mode, hold down A until the
currently selected city code starts to flash. This is the
city code setting screen.
• Before the city code starts to flash, the message
SET Hold will appear on the display. Keep A
depressed until SET Hold disappears and the city
code starts to flash.
2. Keep pressing C until MUTE or KEY is displayed in the upper left corner of the
display.
• See step 3 under “To change the current time and date settings” for information
about how to scroll through setting screens.
3.
Press D to toggle the button operation tone between on
(KEY ) and off (MUTE).
4. After the settings are the way you want, press A to exit
the setting screen.
Note
• The mute indicator is displayed in all modes when
the button operation tone is turned off.
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Alarm ON/OFF
indicator
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Alarm ON/OFF
indicator
Alarm on indicator
Hourly time signal
on indicator
Alarm on indicator
Hourly time signal
on indicator
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Mute indicatorMute indicator
Operation Guide 3202
5
Troubleshooting
Time Setting
■ The current time setting is off by hours.
Your Home City setting may be wrong. Check your Home City setting and correct it, if
necessary.
■ The current time setting is off by one hour.
You may need to change your Home City’s standard time/daylight saving time (DST)
setting. Use the procedure under “To change the current time and date settings” to
change the standard time/daylight saving time (DST) setting.
Sensor modes
■ I can’t change the temperature, barometric pressure, and altitude units.
When TYO (Tokyo) is selected as the Home City, the altitude unit is set automatically
to meters (m), the barometric pressure unit to hectopascals (hPa), and the
temperature unit to Celsius (°C). These settings cannot be changed.
■ The battery indicator ( ) appears while a sensor operation is being
performed.
The battery indicator appears in the upper left corner of the digital
display whenever there is not enough battery power available to
perform a sensor operation in the Barometer/Thermometer Mode
or Altimeter Mode. Sensor operation is disabled while the battery
indicator is displayed.
• Normal operation should return after battery power recovers.
■ “ERR” appears while a sensor operation is in progress.
Subjecting the watch to strong impact can cause sensor malfunction or improper
contact of internal circuitry. When this happens, ERR (error) will appear on the display
and sensor operations will be disabled.
Barometric
Pressure/Temperature
Measurement
Altitude
Measurement
•
If ERR appears while a measurement operation is being performed in a sensor mode,
restart the measurement. If ERR appears on the display again, it can mean there is
something wrong with the sensor.
•
Barometer/Thermometer Mode and Altimeter Mode sensor operations are disabled
whenever there is not enough battery power available to perform a sensor operation.
This is true regardless of the current battery level. In this case, ERR will appear on
the display. This does not indicate malfunction, and sensor operation should resume
once battery voltage returns to its normal level.
• If ERR keeps appearing during measurement, it could mean there is a problem with
the applicable sensor.
Whenever you have a sensor malfunction, take the watch to your original dealer or
nearest authorized CASIO distributor as soon as possible.
■ The barometric pressure differential pointer does not appear on the display
when I enter the Barometer/Thermometer Mode.
• This could indicate sensor error. Try using C to re-enter the Barometer/
Thermometer Mode.
•
The barometric pressure differential pointer is not displayed when the displayed current
barometric value is outside of the allowable measurement range (260 to 1,100 hPa).
World Time Mode
■ The time for my World Time City is off in the World Time Mode.
This could be due to incorrect switching between standard time and daylight saving
time. See “To specify standard time or daylight saving time (DST) for a city” for more
information.
Specifications
Accuracy at normal temperature: ±30 seconds a month
Timekeeping: Hour, minutes, seconds, p.m. (P), month, day, day of the week
Time format: 12-hour and 24-hour
Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099
Other: Home City code (can be assigned one of 48 city codes); Standard Time /
Daylight Saving Time (summer time)
Altimeter:
Measurement range: –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference
altitude
Display range: –10,000 to 10,000 m (or –32,800 to 32,800 ft.)
Negative values can be caused by readings produced based on a reference
altitude or due to atmospheric conditions.
Display unit: 5 m (or 20 ft.)
Measurement timing: 5-second interval for first 3 minutes followed by 2-minute
interval for next 10 hours
Other: Reference altitude setting
Barometer:
Measurement and display range:
260 to 1,100 hPa (or 7.65 to 32.45 inHg)
Display unit: 1 hPa (or 0.05 inHg)
Measurement timing: 5-second interval for first 3 minutes followed by 2-minute
interval for next 10 hours in the Barometer/Thermometer Mode
Other: Calibration; Barometric pressure differential pointer
Thermometer:
Measurement and display range: –10.0 to 60.0°C (or 14.0 to 140.0°F)
Display unit: 0.1°C (or 0.2°F)
Measurement timing: 5-second interval for first 3 minutes followed by 2-minute
interval for next 10 hours
Other: Calibration
Battery indicatorBattery indicator
Pressure Sensor Precision:
Conditions
(Altitude) Altimeter Barometer
Fixed
temperature
0 to 6000 m
0 to 19680 ft.
± (altitude differential × 2%
+ 15 m) m
± (altitude differential × 2%
+ 50 ft.) ft. ± (pressure differential × 2%
+ 2 hPa) hPa
± (pressure differential × 2%
+ 0.059 inHg) inHg
6000 to 10000 m
19680 to 32800 ft.
± (altitude differential × 2%
+ 25 m) m
± (altitude differential × 2%
+ 90 ft.) ft.
Effect of
variable
temperature
0 to 6000 m
0 to 19680 ft.
± 50 m every 10°C
± 170 ft. every 50°F ± 5 hPa every 10°C
± 0.148 inHg every 50°F
6000 to 10000 m
19680 to 32800 ft.
± 70 m every 10°C
± 230 ft. every 50°F
• Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
• Precision is lessened by strong impact to either the watch or the sensor, and by
temperature extremes.
Temperature Sensor Precision:
±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)
World Time: 48 cities (31 time zones)
Other: Daylight Saving Time/Standard Time
Stopwatch:
Measuring unit: 1/100 second
Measuring capacity: 23:59' 59.99"
Measuring modes: Elapsed time, split time, two finishes
Countdown Timer:
Measuring unit: 1 second
Countdown start time setting range: 1 minute to 24 hours (1-hour increments and
1-minute increments)
Alarms: 5 Daily alarms; Hourly time signal
Illumination: LED (Light-emitting diode); Selectable illumination duration
(approximately 1 second or 3 seconds)
Other: Low-temperature resistance (–10°C/14°F); Button operation tone on/off
Battery: One lithium battery (Type: CR2016)
Approximate battery operating time: 3 years under the following conditions:
• 1 illumination operation (1.5 seconds) per day
• 10 seconds of alarm operation per day
• 10 hours of altimeter measurement, once per month
Frequent use of illumination runs down the battery.
City Code Table
City
Code City UTC Offset/
GMT Differential
PPG Pago Pago –11
HNL Honolulu –10
ANC Anchorage –9
YVR Vancouver –8
LAX Los Angeles
YEA Edmonton –7
DEN Denver
MEX Mexico City –6
CHI Chicago
NYC New York –5
SCL Santiago –4
YHZ Halifax
YYT St. Johns –3.5
RIO Rio De Janeiro –3
FEN Fernando de
Noronha –2
RAI Praia –1
UTC
0LIS Lisbon
LON London
MAD Madrid
+1
PAR Paris
ROM Rome
BER Berlin
STO Stockholm
ATH Athens
+2CAI Cairo
JRS Jerusalem
City
Code City UTC Offset/
GMT Differential
MOW Moscow +3
JED Jeddah
THR Tehran +3.5
DXB Dubai +4
KBL Kabul +4.5
KHI Karachi +5
DEL Delhi +5.5
KTM Kathmandu +5.75
DAC Dhaka +6
RGN Yangon +6.5
BKK Bangkok +7
SIN Singapore
+8
HKG Hong Kong
BJS Beijing
TPE Taipei
SEL Seoul +9
TYO Tokyo
ADL Adelaide +9.5
GUM Guam +10
SYD Sydney
NOU Noumea +11
WLG Wellington +12
• Based on data as of December 2009.
• The rules governing global times (GMT
differential and UTC offset) and
summer time are determined by each
individual country.