Module No. 1209/1299
GENERAL GUIDE

1209/1299-1

Alarm Mode

• Press C to change from mode to mode.
• In any mode, press D to illuminate the display for about three seconds. The watch can be set
so that the backlight flashes whenever an alarm sounds.

1

2

3

4

Countdown Alarm Mode

5

1

2

3

4

5

Timekeeping Mode

A

A

B

B
1

2

3

4

The operational procedures for
Module 1209 and 1299 are identical. All of the illustrations in this
manual show Module 1209.

5

P

C

E

C

D

D
[Module 1209]

TIMEKEEPING MODE

Date

Day of week

B

A
1

2

3

4

E

Hour Minutes

Seconds

Seconds

Hour

Both OFF

Day of
Week

Date

Hold down E while in the Alarm Mode to sound the alarm.

COUNTDOWN ALARM MODE

Month

About the backlight
When you switch the backlight function on, the backlight of the watch flashes whenever a daily
alarm or countdown alarm is sounding, or when various signals are sounded in the Stopwatch and
Alarm Modes. For details of each of these operations, see the applicable sections of this manual.
• The backlight of this watch employs an electro-luminescent (EL) light, which loses its illuminating
power after very long term use.
To switch the backlight function on and off

Current time
Mode indicator
A

B
1

2

3

4

E

C

2

3

4

5

2

3

4

seconds

Minutes

To use the countdown timer
1. Press E while in the Countdown Alarm Mode to start the countdown timer.
2. Press E again to stop the countdown timer.
• You can continue countdown timer operation by pressing E.
3. Stop the timer and then press B to reset the countdown time to its starting value.
• The countdown time is automatically reset to its starting value after the alarm stops.

A

B

3

4

5

The Stopwatch Mode lets you measure elapsed time, split times,
and two finishes. You also get Auto-Start and Target Time
functions. The range of the stopwatch is 23 hours, 59 minutes,
59.99 seconds.

To measure elapsed time

When the Daily Alarm is switched on, the alarm sounds for
20 seconds at the preset time each day. Press any button
to stop the alarm after it starts to sound.
When the Hourly Time Signal is switched on, the watch
beeps every hour on the hour.

1. Press E to start the stopwatch.
2. Press E to stop the stopwatch.
• You can resume the measurement operation by pressing E
1/100 second
again.
3. Press B to clear the stopwatch to all zeros (0H 00'00"00).
Seconds

C

E

D

Minutes

To record split times
1. Press E to start the stopwatch.
2. Press B to display the timing up to that point. Stopwatch timing continues internally.
3. Press B to clear the split time and to continue time measurement on the display.
• You can repeat steps 2 and 3 as many times as you want.
4. Press E to stop the time measurement.
5. Press B to clear the stopwatch to all zeros.

To time first and second place finishes

5

To set the alarm time
C

B
2

OFF

ALARM MODE

A

STOPWATCH MODE

5

• The backlight function indicator remains on the display in all modes.
• The above operation controls operation of the backlight function only. It does not affect operation
of audible tones and signals.
• Pressing D at any time illuminates the display for about three seconds, regardless of the
backlight’s on/off setting.
• The watch will emit an audible sound whenever the display is illuminated. This is caused by a
transistor that vibrates when the EL panel lights up. It does not indicate malfunction of the watch.

Hourly time signal on indicator
Mode indicator
Current time

Seconds

1/10 second

3. Press E to increase the selected number or B to decrease it. Holding down either button
changes the selection at high speed.
4. After you set the countdown time, press A to return to the Countdown Alarm Mode.

1

ON

1. Press A while in the Countdown Alarm Mode. The minutes
digit flashes on the display because it is selected .
2. Press C to change the selection in the following sequence.

D

Minutes

Mode indicator Hours
1

The countdown timer can be set within a range of 1 second to 60
minutes. When the countdown reaches zero, an alarm sounds
for 10 seconds or until you press any button.

To set the countdown time

5

In the Timekeeping Mode, hold down B for one or two seconds to switch the backlight function on
and off.

1

Hourly Time
Signal only

Minutes

3. While the seconds digits are selected (flashing), press E to reset the seconds to “00”. If you
press E while the seconds count is in the range of 30 to 59, the seconds are reset to “00” and
1 is added to the minutes. If the seconds count is in the range of 00 to 29, the minutes count
is unchanged.
4. While any other digits (besides seconds) are selected (flashing), press E to increase the
number or B to decrease it. While the day of the week is selected, pressing E advances to
the next day and B goes to the previous day. Holding down either button changes the current
selection at high speed.
5. After you set the time and date, press A to return to the Timekeeping Mode.
• The watch does not make any allowance for leap years. Be sure to manually set February 29
(when one occurs) to the appropriate date.
• If you do not operate any button for a few minutes while a selection is flashing, the flashing stops
and the watch goes back to the Timekeeping Mode automatically.

Backlight
function
indicator

Daily Alarm
only

To test the alarm

PM indicator

4

5

[Alarm ON Indicator/Hourly Time Signal ON Indicator]

Both ON

1. Press A while in the Timekeeping Mode. The seconds
digits flash on the display because they are selected.
2. Press C to change the selection in the following
sequence.

D

3

4

5

C

2

3

Press B while in the Alarm Mode to change the status of the Daily Alarm and Hourly Time Signal
in the following sequence.

To set the time and date

1

2

To switch the Daily Alarm and Hourly Time Signal on and off

This watch is equipped with a backlight that can be set to
flash whenever an alarm sounds. For details, see “About
the backlight”.
• In the Timekeeping Mode, press E to switch between
the 12-hour and 24-hour formats.
• In the Timekeeping Mode, the Graphic Display indicates
the counting of seconds.

Month

1

E

[Module 1299]

Graphic display

Stopwatch Mode

E
D

Hour Minutes
Alarm on indicator

1. Press A while in the Alarm Mode. The hour digits flash
on the display because they are selected .
• At this time the Daily Alarm is switched on automatically.
2. Press C to change the selection in the following
sequence.
Hour

Minutes

3. Press E to increase the selected digits and B to decrease them. Holding down either button
changes the selection at high speed.
• The format (12-hour and 24-hour) of the alarm time matches the format you select for normal
timekeeping.
• When setting the alarm time using the 12-hour format, take care to set the time correctly as
morning or afternoon (P) .
4. After you set the alarm time, press A to return to the Alarm Mode.

1.
2.
3.
4.
5.

Press
Press
Press
Press
Press

E to start the stopwatch.
B when the first finisher crosses the line, and record the time.
E when the second finisher crosses the line.
B to display the finishing time of the second finisher.
B again to clear the stopwatch to all zeros.

About the Auto-Start function
With the Auto-Start function, the watch performs a 5-second countdown. When the countdown
reaches zero, stopwatch operation starts automatically. During the final three seconds of the
countdown, a beeper sounds with each second.
To use the Auto-Start function
B

A
1

2

3

4

5

E

C
D

1. While the display is showing all zeros (0H00'00"00) in the
Stopwatch Mode, press B.
• The upper display shows a count of 5 seconds, which is the
starting value of the Auto-Start countdown.
2. Press E to start the countdown. When the countdown
reaches zero, the watch emits a long beep and the stopwatch
begins operation.
• To stop the Auto-Start countdown and return to the initial
countdown display, press B.
• Pressing E while the Auto-Start countdown is in progress
immediately starts the stopwatch.

1209/1299-2
About the Target Time function
With the Target Time function, an alarm sounds for five seconds whenever the time being kept by
the stopwatch reaches a target time you have preset. To activate the Target Time function, simply
set a target time. The function is automatically deactivated whenever the target time is set to
0H00'00".
To set the Target Time
Target time indicator
B

A
1

2

3

4

5

E
C
D

1. While the display is showing all zeros (0H00'00"00) in the
Stopwatch Mode, press A, and the hours digit of the target
time starts to flash. It flashes because it is selected .
• You can also press A in the above procedure after pressing
B to display the Auto-Start countdown time.
2. Press C to change the selection in the following sequence.
Hours

Minutes

Seconds



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 1997:08:29 20:57:48
Producer                        : Acrobat Distiller 3.0 for Power Macintosh
Keywords                        : WAT
Subject                         : 
Creator                         : Adobe PageMaker 6.0J
Title                           : QW-1209/1299 (Operation)
Author                          : MAS
Modify Date                     : 1998:11:13 18:19:07
Page Count                      : 2
Page Mode                       : UseThumbs
EXIF Metadata provided by EXIF.tools

Navigation menu