MA1010-EA

Operation Guide 5203 5204
••Your watch may differ somewhat from the one shown in the illustration.

To set the time

Hour hand
Minute hand
First click
(Setting Day)

Second click
(Setting Time)
Crown
(Normal position)

24-hour disk
Day
Second hand

1. Pull the crown out to the
second click.
••At this time, the second
hand will move to the
12 o’clock position and
stop there.
2. Set the hands by rotating the
crown. Rotate the crown to
move the hands clockwise.
Move the minute hand four or
five minutes past the time you
want to set, and then back it
up to the proper setting.
••Make sure that you also
set the 24-hour disk to the
correct hour of the day.
3. Push the crown back in to
the normal position to restart
timekeeping.

To set the day

1. Pull the crown out to the first click.
2. Set the day by rotating the crown towards you.
3. Push the crown back in to the normal position.
••Avoid changing the date setting while the current time is between 9:00 p.m. and
1:00 a.m.

■■ For a watch with an elapsed time bezel
mark with the
Rotate the elapsed time bezel to align the
minute hand.
After certain amount of time elapsed, read the graduation on
the elapsed time bezel which the minute hand points to.
The elapsed time is indicated.
Elapsed time bezel

••Some water resistant models are equipped with a screw
lock crown.
••With such models, you must unscrew the crown in the
direction noted in the illustration to loosen it before you can
pull it out. Do not pull too forcibly on such crowns.
••Also note that such watches are not water resistant while
their crowns are loosened. Be sure to screw the crowns
back in as far as they will go after making any setting.

Specifications
Accuracy at normal temperature: ± 20 seconds a month
Display: 3 analog hands (timekeeping hour and minutes, stopwatch 1/100 seconds),
3 dials (timekeeping 24-hour and seconds, stopwatch minutes), day
Stopwatch function: Measuring capacity: 59'59.99"/Measuring unit: 1/100 second
Measuring modes: Elapsed time
Battery: One silver oxide battery (Type: SR927W)
Approximately 2 years on type SR927W (assuming one stopwatch operation 60 min./
day)

Using the Stopwatch
Stopwatch minute hand
* This hand rotates and
indicates the second
count during the first
60 seconds.

Stopwatch
1/100 second hand
Stopwatch second
hand

The stopwatch lets you measure elapsed time up to 59 minutes, 59.99 seconds.

To measure elapsed time (First 60 seconds)

1. Press A to start the stopwatch.
2. Press A to stop the stopwatch.
••You can resume the measurement operation by pressing A again.
3. Check the elapsed time.
••The example below shows an elapsed time of 40.30 seconds.

Stopwatch 1/100 second hand
[30]
Stopwatch second hand
[40 seconds]

••Press B to reset the stopwatch.
This will enter the Timekeeping Mode.

To measure elapsed time (After the first 60 seconds)

1. Press A to start the stopwatch.
••During elapsed time measurement, the stopwatch 1/100 second hand
automatically rotates for the final second of each minute.
2. Press A to stop the stopwatch.
••You can resume the measurement operation by pressing A again.
3. Press A and the stopwatch 1/100 second hand will move to the
1/100 second count.
••If the elapsed time operation was stopped during the final second of each
minute, the stopwatch 1/100 second hand will already be pointing at the
1/100 second count. Do not press A at this time, because doing so will
restart the elapsed time operation.
4. Check the elapsed time.
••The example below shows an elapsed time of two minutes, 40.30 seconds.
Stopwatch minute hand
[2 minutes]

Stopwatch 1/100 second hand
[30]

Stopwatch second hand
[40 seconds]

••Press B to reset the stopwatch.
This will enter the Timekeeping Mode.
Notes:
••Do not try to perform stopwatch operations while the crown is pulled out either
to the first or second click. If you try to press a button, you might accidentally
cause the crown to rotate and change the current time or day setting.
••If the starting positions of the stopwatch second hand and 1/100 second hand
become misaligned, use the following procedures to adjust the positions of the
hands so they point to 12 o’clock when the stopwatch is reset.

To adjust the positions of the stopwatch hands

1. Press B to reset the stopwatch, and check the alignment of the stopwatch
second hand and 1/100 second hand.
2. Pull out the crown to the second click.
3. Press A to move the stopwatch 1/100 second hand.
4. If the stopwatch minute hand is aligned correctly, proceed to step 5. If the
stopwatch minute hand is also misaligned, press B to move the stopwatch
second hand.
5. After making the adjustments you want, push the crown back in to its normal
position.
••Note that pulling the crown out also stops the timekeeping second hand. After
performing the above procedure, you should also adjust the timekeeping setting.

1



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 2010:11:04 17:38:45+09:00
Creator                         : Adobe InDesign CS3_J (5.0)
Modify Date                     : 2010:11:04 17:51:27+09:00
Title                           : QW-5203_5204
Author                          : CASIO COMPUTER CO., LTD.
XMP Toolkit                     : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24
Instance ID                     : uuid:1181ad66-25c5-4403-9277-9e07dad2add1
Document ID                     : adobe:docid:indd:354bfa74-e7e8-11df-be45-d340c212d82f
Rendition Class                 : proof:pdf
Derived From Instance ID        : 354bfa73-e7e8-11df-be45-d340c212d82f
Derived From Document ID        : adobe:docid:indd:354bfa72-e7e8-11df-be45-d340c212d82f
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:f7ceeac3-baa8-4332-9164-3a6a44c446b7, uuid:3b6c4ce7-c49d-40ec-b8dd-a54a7cd39ddb, uuid:bb6ec153-63e0-4530-a570-49bb400c841d, uuid:21508c92-b8e9-4e7b-b90b-660efadf5ff1, uuid:d238c346-b30a-4069-9c07-36bbb5ed7d01, uuid:2f6501f2-f535-4c1e-8d36-3902c2e07d5d, uuid:45f983a8-9f23-482b-b0d4-7a634e33ec3c, uuid:d06431d2-ca23-400a-ba13-65bad3b7b178
Manifest Reference Document ID  : uuid:284ceb60-712f-4fcb-857d-1d666b79fe76, uuid:284ceb60-712f-4fcb-857d-1d666b79fe76, uuid:284ceb60-712f-4fcb-857d-1d666b79fe76, uuid:284ceb60-712f-4fcb-857d-1d666b79fe76, uuid:892e2ca8-9434-4a14-92f5-3b8049c9d683
Metadata Date                   : 2010:11:04 17:38:46+09:00
Creator Tool                    : Adobe InDesign CS3_J (5.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 12643 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 1
Page Mode                       : UseOutlines
Page Layout                     : OneColumn
EXIF Metadata provided by EXIF.tools

Navigation menu