Casio Dt 800Rf Users Manual
DT-800RF DT800
DT-800RF to the manual 8798f09d-fc1e-4723-ab57-3658d5c72aad
2015-01-21
: Casio Casio-Dt-800Rf-Users-Manual-242689 casio-dt-800rf-users-manual-242689 casio pdf
Open the PDF directly: View PDF .
Page Count: 64
Download | |
Open PDF In Browser | View PDF |
Supported Equipment Manual For the DT-800RF Device Manufactured by Casio Copyright © 1996 - 2006 by Connect, Inc. All rights reserved. This document may not be reproduced in full or in part, in any form, without prior written permission of Connect Inc., 1701 Quincy Avenue, Suites 5 & 6, Naperville, IL 60540. Connect, Inc. makes no representation or warranties with respect to the contents of this document and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Connect, Inc. reserves the right to revise this publication and to make changes to it from time to time without obligation to notify any person or organization of such revision or changes. Trademarks PowerNet OpenAir™, OpenAir Linux™, OpenAir Windows™, OpenAir 400™, PowerNet Twin Client™, and PowerNet AirLinc™ are trademarks of Connect, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Production This manual was written, edited, and produced by: Connect, Inc. 1701 Quincy Avenue, Suites 5 & 6 Naperville, IL 60540 www.connectrf.com Printed in the U.S.A. Please let us know about any errors in this document at: http://207.241.78.223/isoxpert/calltrak.nsf/WebTracking?OpenForm Table of Contents Chapter 1 • Introduction............................................................................................. 1-1 Description………………… ..........................................................................................1-1 Picture………………………...........................................................................................1-2 Setup Requirements…….. ...........................................................................................1-2 Accessories……………….............................................................................................1-2 Operating System………… ..........................................................................................1-4 Chapter 2 • Terminal Setup........................................................................................ 2-1 Running Setup from a Download File ........................................................................2-1 Installation………………… ...........................................................................................2-2 Running the Manager…… ………………………………………………………………….2-4 Quick Start………………… ...........................................................................................2-5 Configuring the Manager ....................................................................................2-5 Configuring the Terminal for Download ..............................................................2-9 Terminal Settings .............................................................................................2-10 Starting a Telnet Session .................................................................................2-11 Standard Setup…………….........................................................................................2-12 Setup Using Twin Client Manager ....................................................................2-12 Terminal Setup Using Twin Client Menus ........................................................2-18 Authorizing PowerNet.......................................................................................2-20 Software Management…… ........................................................................................2-22 Auto-Configuration ...........................................................................................2-22 Chapter 3 • Keypad Configuration ............................................................................ 3-1 Keypad Figures…………… ..........................................................................................3-1 Keypad Table……………… ..........................................................................................3-4 Chapter 4 • Error Message Resolution Guide .......................................................... 4-1 Supported Equipment Manual • March, 2006 iii This page is intentionally blank. iv Supported Equipment Manual • March, 2006 Chapter 1 • Introduction Description The DT-800RF has a versatile high-speed scanning (100 scans per second) that ensures a rapid first-time read rate and high data integrity. Its combination of distance and contact laser scanning allows bar codes to be easily read even when badly printed on curved and irregular surfaces. Amongst the lightest weight terminals in its class, the compact lightweight design of the DT-800RF reduces operator fatigue over extended usage periods. Its backlit display can be illuminated, enabling readings to be clearly seen in the darkest of work environments. This terminal has a world-class water splash proof (IPX II standard) that provides continuous operations, even in the rain. Using the latest multi-drop communications technology, data can be collected at many different networked points connected to a single PC. Low-power circuitry and an automatic power-off feature conserve battery life to the maximum and provide more usage time before replacement. A rechargeable battery reduces the need to dispose of dead batteries and helps to conserve the environment. The DT-800RF’s 160 x 160-dot screen displays extensive lines of information. This touch screen can also be used for entering data quickly and easily. You may choose between 2.6 or 10 Mbytes of memory to meet your specific requirements. Control functions (such as “Help” or “Send”) can be assigned to the DT-800RF special function keys to further enhance operation. Master I/O boxes, including SCSI or Ethernet connection, allow the configuration of a large-scale system with satellite I/O boxes for high speed, large volume data transfer. The DT-800RF can be set to read all common bar code symbologies with a narrow bar width as small as 0.125mm. Infrared communications on this terminal allow data to be downloaded or uploaded without the need to connect any cables, thus ensuring trouble-free connection to a host system. For more information, contact www.casio.com. Supported Equipment Manual • March, 2006 1-1 Introduction Picture Setup Requirements Installation of PowerNet Twin Client requires, at a minimum, the following: • A Pentium-class processor • 32 MB of RAM • 10 MB of free hard disk space available • Microsoft Windows 95, 98, ME, XP, or NT/2000 operating system Accessories The following accessories are available for the DT-800RF: I/O Box • DT-860IOE (satellite I/O box) • DT-865IOE (master I/O box) Charger (Single-Pack) • DT-820CHGE (Quick charger) Lithium Ion Battery Pack • 1-2 DT-823LI Supported Equipment Manual • March, 2006 Accessories AC Adaptors • DT-9020ADPG (AC adaptor (230V) for DT-820CHGE) • DT-9020ADPU (AC adaptor (120V) for DT-820CHGE) • DT-825ADP-G (AC adaptor (230V) for I/O boxes) • DT-825ADP-U (AC adaptor (120V) for I/O boxes) Cables • DT-881RSC-E: RS232C Modem cable • DT-882RSC-E: RS232C Cross cable (between DT860IO-E and PC: 25pin male) • DT-883RSC-E: RS232C Cross cable (between DT860IO-E and PC: 25pin female) • DT-887AX: RS232C Cross cable (between DT860IO-E and PC: 9pin female) • DT-888RSC: Modular Cable • DT-889AX: Cable (between DT-800RF and PC) • SB-751HF: SCSI cable (between DT865IO-E and PC: Centro 50pin full male) • SB-752HH: SCSI cable (between DT865IO-E and PC: Centro 50pin half male) • SB-753HP: SCSI cable (between DT865IO-E and PC: Pin type half 50pin male) Supported Equipment Manual • March, 2006 1-3 Introduction Operating System Version of the Operating System The version of the operating system on a DT-800RF terminal is 2.00. Finding the Version of the Operating System The version of operating system will appear on a terminal screen when the terminal is rebooted. For rebooting instructions, see Command Mode Boot in the Quick Start section. 1-4 Supported Equipment Manual • March, 2006 Chapter 2 • Terminal Setup Running Setup from a Download File The downloaded file is a compressed archive. After extraction using a utility such as WinZip or PKWARE, folders are created on the hard disk as shown in the following figure. Click on the Disk1 folder to view the files as shown in the following figure. Click on the Setup application and proceed to the following section entitled Installation for further instructions. Supported Equipment Manual • March, 2006 2-1 Terminal Setup Installation The InstallShield wizard runs and presents the following screen. Click on Next to begin the installation process. 2-2 Supported Equipment Manual • March, 2006 Installation To change the default Destination Location, click on Browse and select a location. Then click on Next. The default folder is PowerNet. This default may be changed either by selecting an existing program group or by typing in a new name at the prompt. Then click on Next. When the installation is complete, reboot the system to initialize the Twin Client software. Supported Equipment Manual • March, 2006 2-3 Terminal Setup a. To reboot the system immediately, click on Finish. b. To reboot later, click on the option to restart the computer later, and click on Finish. Running the Manager The PowerNet Twin Client Manager is the utility that manages the terminal software and configurations. Select Start, Programs, PowerNet, and Twin Client Manager. The PowerNet Twin Client Manager screen appears as shown in the following figure. This is the administrator's main screen, and all functions are accessed from its menu bar, tool bar, and tabs. Menu Bar The menu bar provides access to the functions used to configure the terminals and manage their software. Toolbar Under the menu bar, the tool bar provides shortcuts to major features. The toolbar can be turned on or off by changing the Toolbar parameter found on the View menu. The shortcuts available from the toolbar are as follows: Create a new terminal configuration. Open an existing terminal configuration. Save the current terminal configuration. Download the configuration to terminal. Download software to terminal. Configure terminals automatically over the wireless network. View PowerNet Twin Client Manager version. The PowerNet Twin Client Manager is now successfully installed and ready for use. The Quick Start section below provides detailed instructions for quickly configuring the terminal and starting a telnet session. 2-4 Supported Equipment Manual • March, 2006 Quick Start Quick Start Quick Start describes how to prepare the Twin Client Manager and the Casio terminal for a Telnet session with the host. Following an initial serial download, the terminal software and configuration is managed automatically, over the wireless network. Configuring the Manager The first step is to configure the Twin Client Manager to meet site-specific requirements, and then prepare it for the automatic management of the terminal software and IP addresses. This simple procedure will require only a few minutes to complete. Setting the Emulation Click on Start, Programs, PowerNet, and Twin Client Manager. Select the Settings menu, as shown below. Click on Emulation, select the desired emulation, and click on OK. Setting the Servers The Servers are the Telnet host systems the terminals will access. Supported Equipment Manual • March, 2006 2-5 Terminal Setup To set these addresses from the Settings menu, click on Servers and then click on Add. Enter the name of each server, its IP Address and IP port (normally 23 for Telnet servers), and emulation type. Then click on OK. Repeat this step for each telnet server the terminals are required to access. If an error is made in the name, IP Address, IP Port number, or Terminal emulation type, click on the line that is in error and then click on the Edit button to make the corrections. Setting Terminal Model and COM Port The default terminal model is DT800, and the default serial connection to the Casio cradle is through COM1. To select a specific Casio terminal model and keypad, or to change the COM port assignment, click on the Options menu as shown. The default terminal model, DT800, represents the default setup for all Casio terminals under PowerNet. To maintain compatibility with existing Casio Telnet client keyboard layouts, a specific terminal model and keypad must be selected from the Terminal Model window. 2-6 Supported Equipment Manual • March, 2006 Quick Start Saving the Configuration Click File and Save As. Enter a name for this configuration. For the purposes of this example, the name is vt100. Supported Equipment Manual • March, 2006 2-7 Terminal Setup Download Files to Terminal Select Terminal and Send Program Files to Terminal from the menu bar. The program asks if you want to include configuration files. Select Yes. The Casio Load Options screen appears telling you what actions to perform on the terminal. The first three of these instructions perform the terminal reboot. The remainder perform the actual download. Click OK. The Casio CD-ROM, distributed with Casio terminals, contains LMWIN2 in the directory \Tool\Dt800\LMWIN201. Copy the LMWIN2 utility into any directory on your PC. Next, install the PowerNet Twin Client software on the Casio terminal. To do this, connect the serial load cable from a serial port on the PC to the communications port of the terminal cradle or to a Casio terminal. On the PC, the Download/Upload Utility screen is displayed. Note that this program is LMWIN.EXE, which is distributed separately. 2-8 Supported Equipment Manual • March, 2006 Quick Start Select Execute from the menu bar, then select Link Manager and select Start Link Manager. Note: A shortcut is to just click on the start icon. To stop the download, select Execute then Link Manager Stop, or press the Stop key, the fifth icon from the left under the Download/Upload Utility menu. After the files are sent, close the Download/Upload Utility to return to the Twin Client Configuration Utility main screen and proceed. The PowerNet Twin Client startup screen is displayed on the terminal as follows. Twin Client © 1991-2006 Connect, Inc. Keypress to Continue Note: The date of 2006 is updated on the terminal at the time of a new release. The terminal is now ready to establish a telnet session with the Host system. Configuring the Terminal for Download The terminal is prepared for the addition of Twin Client by booting to command mode, and setting the serial port parameters as described in this section. This simple procedure is described in the following sections, and requires only a few minutes to complete. Supported Equipment Manual • March, 2006 2-9 Terminal Setup Connecting the Cradle The terminal download requires a serial connection between the terminal and the PC through a cradle. Connect the serial load cable from a serial port on the PC to the communications port of the terminal cradle or to a Casio terminal. In preparation for this download perform the following: • Make sure you have copied the LMWIN utility to any directory on your PC. • Connect the selected serial port on the PC to the cradle with a null modem cable. Use COM Port 1. • Verify that the cradle is powered on. • If you are using a cradle, configure the cradle baud rate to 115200. • Set the dip switches on the bottom of the cradle. There are ten switches. The up position of a switch is the on position. The settings for the ten switches are shown below to set the cradle baud rate to 115200. Switch Setting 1 On 2 Off 3 Off 4 Off 5 On 6 Off 7 On 8 On 9 On 10 On When using a cable, the baud rate to select is also 115200. Terminal Settings Command Mode Boot On the portable terminal, power the terminal OFF, then boot the terminal using the key sequence as shown in the following table. Command Mode Boot Sequences Following Power OFF Terminal Model & Keypad DT-800RF Key Sequence Press the FNC and 0 keys, then press and release the PWR key, then release the FNC and 0 keys. The System Menu is displayed. 1. 2. 3. 4. 5. 6. 7. SYSTEM MENU EXECUTE AP SET MODE DATE/TIME TRANSMIT CALIBRATION VERSION SS UTILITY 1. Select 7: SS Utility and then 1: Environment. 2. Enter the IP Address, Netmask, Gateway, Domain, etc. 2-10 Supported Equipment Manual • March, 2006 Quick Start 3. 4. 5. 6. 7. 8. 9. 10. 11. Press the Clear key. Select 1: yes. Press the Clear key to return to the system menu. Select 4: Transmit, 4: Utility and 4: Change memory size. Enter 640 and then press the Enter key. Select yes to change the size. Press the Clear key to return to the system menu. Select 1: Execute AP. Select Enter for “yes” to execute the AP. The terminal is now configured to accept a download from Twin Client Manager. Starting a Telnet Session At the Twin Client main menu on the terminal, press any key to establish the connection. Until the terminal has been authorized, the following screen is displayed. RECOVERABLE ERROR Terminal not Authorized for Twin Client Keypress to Continue It is not necessary to authorize the terminal at this time, so press any key to continue. The terminal will establish a connection with the host system and start emulation. If the terminal fails to connect to the host, refer to the following table for the possible causes and the related corrective actions. Failure Cause Corrective Action Incorrect Host IP address Correct the Host List address on the terminal. Refer to Terminal Setup Using Twin Client Menus under Standard Setup for instructions. Access Radio Setup menu and correct the netmask value. Refer to Terminal Setup Using Twin Client Menus for instructions. Incorrect netmask value After a Telnet session has been successfully established, the terminal will remain in session for a maximum of 30 minutes at a time until it has been authorized. Once authorized, there is no software restriction on the session time. The instructions for authorizing the terminal are presented in Authorizing PowerNet. Supported Equipment Manual • March, 2006 2-11 Terminal Setup Standard Setup The default terminal setup is sufficient for most installations. However, to meet sitespecific requirements, it may be necessary to customize terminal operation. The standard setup options simplify this process and can be modified using one of the following methods: • Using the Twin Client Manager. • Using the Twin Client terminal menu system. Standard Setup describes how to use the Twin Client Manager and the terminal menu systems to set up the terminal. Also described are the methods for authorizing the terminal software. Setup Using Twin Client Manager The Twin Client Manager provides a Standard Settings tab for automatic setup of the terminals. The options within this tab vary according to the emulation selected, each of which is described below. VT Settings Select the VT emulation setup by clicking on the Settings menu and then the Emulation menu, as shown below. Then click on the VT100 or VT220 selection, as shown below. Click on OK after the selection is made, and return to the main Twin Client Manager menu. The standard settings tab will now reflect the settings for VT emulation. 2-12 Supported Equipment Manual • March, 2006 Standard Setup Quadrant Mode The scrolling list defines the rules by which the terminal display is positioned in the larger host display. As defined by Twin Client, quadrants are fixed position “windows” in the host display, and the terminal display is located on whatever quadrant contains the current cursor position. Off disables quadrant processing and Twin Client simply centers the current host input field in the terminal display. On enables quadrant processing. However, input fields that cross quadrant boundaries result in a shift to the left in order to locate as much of the current input field on the terminal display. Soft always positions on a quadrant boundary regardless of input field boundaries. Viewing keys are enabled. Hard is the same as Soft except the viewing keys are disabled. Lock locks the terminal display origin (upper left corner) to fixed row and column (x,y) coordinates in the host display. The coordinates are zero-based. Font Size This check box enables (checked) or disables (unchecked) the display of characters in 10x20 font. Key Click This check box enables (checked) or disables (unchecked) audible key clicks from the terminal. Default is on (checked). Supported Equipment Manual • March, 2006 2-13 Terminal Setup Printer Type This scrolling list selects the attached printer type. The default value is none, indicating no printer is attached. 5250 Settings Select the 5250 emulation setup by clicking on the Settings menu and then the Emulation menu, as shown below. Then click on the 5250 selection, as shown below. Click on OK after the selection is made, and return to the main Twin Client Manager menu. The standard settings tab will now reflect the settings for 5250 emulation. 2-14 Supported Equipment Manual • March, 2006 Standard Setup Quadrant Mode The scrolling list defines the rules by which the terminal display is positioned in the larger host display. As defined by Twin Client, quadrants are fixed position “windows” in the host display, and the terminal display is located on whatever quadrant contains the current cursor position. Off disables quadrant processing and Twin Client simply centers the current host input field in the terminal display. On enables quadrant processing. However, input fields that cross quadrant boundaries result in a shift to the left in order to locate as much of the current input field on the terminal display. Soft always positions on a quadrant boundary regardless of input field boundaries. Viewing keys are enabled. Hard is the same as Soft except the viewing keys are disabled. Lock locks the terminal display origin (upper left corner) to fixed row and column (x,y) coordinates in the host display. The coordinates are zero-based. Font Size This check box enables (checked) or disables (unchecked) the display of characters in 10x20 font. Key Click This check box enables (checked) or disables (unchecked) audible key clicks from the terminal. Default is on (checked). Supported Equipment Manual • March, 2006 2-15 Terminal Setup Printer Type This scrolling list selects the attached printer type. The default value is none, indicating no printer is attached. 3270 Settings Select the 3270 emulation setup by clicking on the Settings menu and then the Emulation menu, as shown below. Then click on the 3270 selection, as shown below. Click on OK after the selection is made, and return to the main Twin Client Manager menu. The standard settings tab will now reflect the settings for 3270 emulation. 2-16 Supported Equipment Manual • March, 2006 Standard Setup Quadrant Mode The scrolling list defines the rules by which the terminal display is positioned in the larger host display. As defined by Twin Client, quadrants are fixed position “windows” in the host display, and the terminal display is located on whatever quadrant contains the current cursor position. Off disables quadrant processing and Twin Client simply centers the current host input field in the terminal display. On enables quadrant processing. However, input fields that cross quadrant boundaries result in a shift to the left in order to locate as much of the current input field on the terminal display. Soft always positions on a quadrant boundary regardless of input field boundaries. Viewing keys are enabled. Hard is the same as Soft except the viewing keys are disabled. Lock locks the terminal display origin (upper left corner) to fixed row and column (x,y) coordinates in the host display. The coordinates are zero-based. Font Size This check box enables (checked) or disables (unchecked) the display of characters in 10x20 font. Key Click This check box enables (checked) or disables (unchecked) audible key clicks from the terminal. Default is on (checked). Supported Equipment Manual • March, 2006 2-17 Terminal Setup Printer Type This scrolling list selects the attached printer type. The default value is none, indicating no printer is attached. Terminal Setup Using Twin Client Menus The Twin Client terminal software provides an internal menu system for configuring certain parameters on the terminal and for switching between “server” and “telnet” mode of operation. To access this menu system, press the uppercase C at the startup screen as shown in the following figure. Twin Client © 1991-2006, Connect, Inc. Keypress to Continue The next screen displays the menu options. Cursor to the appropriate option and press Enter. Edit Menu Options Edit Mobile Unit IP Edit Server/Host IPs Edit License Key Run Site Survey Switch Client Modes Run Client Emulator Exit to OS Use the Up-Arrow and Down-Arrow keys to navigate the menu, and press Enter to select the highlighted option. Each menu option is described below. Edit Mobile Unit IP The IP list contains the terminal IP address, the Subnet mask, and the Router IP address. Enter the appropriate address and select F3 to save and/or F7 to quit. IP 206.232.71.38 SN 255.255.255.0 RT 206.232.71.1Save Quit Press F3 to save the configurations. Edit Server/Host IPs If you wish to change the host IP address or addresses using the terminal menus, select this option and enter up to four Host IP addresses as required. 2-18 Supported Equipment Manual • March, 2006 Standard Setup Host 0 IP 206.183.67.155 Port 23__ Save Quit Press F3 to save the configurations. Edit License Key The client software can be authorized automatically, as described in the next section, Authorizing PowerNet. This menu option permits authorization of each terminal manually. Select this option to obtain the terminal's Identification Code, which is used to obtain the Authorization code from the Connect web site, as described in the next section. The 12-digit value displayed at the top of the terminal screen is the Identification Code for the terminal. 00A0F826E614 Authorization ______________ not authorized Save Quit Type the authorization code into the field as it appears on the WEB site. Punctuation characters, such as the hyphen (-), are not required. Press F3 to save the authorization code. Run Site Survey This option (a feature of Spectrum 1) is applicable to Release 5.0 and may be obsolete for your terminal. Switch Client Modes The PowerNet Twin Client normally operates in "telnet" mode, which provides direct connection to Telnet hosts. It can also operate in "server" mode, through a PowerNet OpenAir server. Select this menu option to switch between server and telnet modes of operation. Note that the host socket address for the PowerNet OpenAir servers is 1800, which must also be changed in the Edit Server/Host IPs menu described at the beginning of this section. Run Client Emulator After all desired changes have been made, select this option to return to the Twin Client main menu. Then press any key to establish the Telnet session and begin emulation. Refer to Starting a Telnet Session under Quick Start for further instructions. Supported Equipment Manual • March, 2006 2-19 Terminal Setup Authorizing PowerNet Each PowerNet Twin Client will run for 30 minutes at a time without authorization. Uninterrupted operation for a production environment is the result of authorizing the software. Authorization codes are obtained from the Connect Website at http://www.connectrf.com on the Partner Services page. Click on the Generate Authorization icon at the top of the page. Manual Authorization The procedure for manually setting the Authorization code on the terminal is described in the section entitled Edit License Key in Terminal Setup Using Twin Client Menus. Add Licenses The Add Licenses feature is used when adding additional licenses to an already site licensed Twin Client manager. An example of this is the instance in which Twin Client manager is licensed for 10 licenses, and the customer purchases another 10 licenses to make a total of 20 licenses. From Twin Client manager, choose Authorization from under the Settings menu. Click on the Add Licenses button. A pop-up box appears with the machine ID and a space for the additional licenses authorization code. 2-20 Supported Equipment Manual • March, 2006 Standard Setup Enter the additional license’s authorization code and click on OK. Use the machine ID in the pop-up box instead of the original machine ID to get your authorization code. If adding users, click on the Add Licenses button before generating the authorization code to get the most current machine ID. Transfer Authorization The Transfer Authorization feature is used when moving a site license from one PC to another. After Twin Client manager is installed on a new PC, you will need the system/machine ID for it. From Twin Client manager, select Authorization from under the Settings menu. Note: This feature only works if there are licenses remaining on the old PC. Supported Equipment Manual • March, 2006 2-21 Terminal Setup Software Management In addition to providing functions for the download of files to the terminal via the traditional serial connection, the Twin Client Manager also provides for the management of terminal software and configurations automatically over the wireless network. This section entitled Software Management describes the automated capability in detail. Additional manual operations involving serial download options are described at the end of this section. Auto-Configuration The Auto-Configuration form is accessed from the Twin Client Manager Settings menu. Note: If no options are displayed, click the Advanced<< button. Enabling Automatic Downloads Click to put a check in the box that allows terminal to be automatically configured via RF to enable automatic downloading. In the event another PC on the network is already configured and active, the following warning message is displayed. 2-22 Supported Equipment Manual • March, 2006 Software Management Synchronizing Configuration Files Click to put a check in the Synchronize Configuration Files box to enable automatic synchronization of configuration files on the terminal. When the terminal is command booted, its configuration files will be compared with the most recent on the PC. The terminal is updated automatically if it does not have the latest revision. Synchronizing Program Files Click to put a check in the Synchronize Program Files box to enable automatic synchronization of program files on the terminal. When the terminal is command booted, its program files will be compared with the most recent on the PC. The terminal is updated automatically if it does not have the latest revision. Automatic IP Address Assignment New terminals will be assigned IP addresses automatically if the following box is checked. Note: Do not check this option if a DHCP server is configured to manage address assignments. To set the addresses, click on the Addresses button to access the Segment Address Assignments dialog box, as shown in the following figure. Enter the desired range in the From and To boxes as shown above, and then click on Add. Supported Equipment Manual • March, 2006 2-23 Terminal Setup Creating New Groups New groups, with different configurations, can be created by clicking on Terminal Group Manager, and then clicking the right mouse button as shown. After the new group has been created, the group settings option becomes available for change, as shown below. After the Configuration File and all of the other parameters have been set, the group is made active by clicking on the Active check box. 2-24 Supported Equipment Manual • March, 2006 Software Management Setting the Segment Checking the Segment button restricts a terminal group to a range of IP addresses. The IP Address can be any valid address on the segment, as it is used only to identify the segment. The setting of the Net Mask can be used to restrict the range. This feature is useful for segregating terminal groups by location. Setting Force Reload Clicking on the Force Reload button forces all terminals within a group to be automatically updated. The following warning message appears. Click on the Yes button to force the reload. Setting the Default Terminal Group New terminals that have not yet been assigned to any group are initially assigned to the default group in effect when they are command booted. Supported Equipment Manual • March, 2006 2-25 Terminal Setup Any group can be made the default group by clicking on the group, and then clicking on the right mouse button. Then click on the Make Default option. Reassigning Terminals After a terminal has been configured and assigned to the default group, it can be reassigned to a new group by clicking on the terminal icon as shown below. Then, holding the mouse button down, drag the terminal icon to the desired group as shown next. Release the mouse button, which reassigns the terminal. The next time the terminal is rebooted, it will be reconfigured as defined in the group specification. 2-26 Supported Equipment Manual • March, 2006 Chapter 3 • Keypad Configuration Keypad Figures Casio DT-800RF 5250 del FNC reset BS LOCK PWR L R newline F17 F7 numbovr F8 redraw F9 7 8 9 F17 F7 F18 F8 dup F4 refresh insert F5 stat 4 F19 F9 nullend F6 dup 5 6 F14 F24F F15 F5 F17 F1 help 18 F2 print 1 F11 F16 2 3 F21F1 F12 F22 clear F10 sreq F20 attn F23 F3 fexit ENT fld- F2 roll↑ fld+ vw↑ F6 roll↓ F4 F3 vw← home vw→ F5 F13 0 CLR F1 F6 FF3 fm top vw↓ F7 bot F8 Left Func Right keytop Left + Func Supported Equipment Manual • March, 2006 Right + Func 3-1 Keypad Configuration Casio DT-800RF, 3270 del FNC BS LOCK PWR L F17 R F7 F8 F9 7 8 9 F18 F4 4 F15 pa2 F6 F3 3 F12 F22 F23 ENT 0 sreq F13 F10 CLR F20 attn fld- F2 home vw→ F5 F16 pa3 2 F21 clear vw← 6 F5 F2 print 1 F1 F6 5 F14 F4 F24 pa1 F1 help F11 F19 F5 fld+ F4 F3 eof vw↑ F6 vw↓ F7 F8 Left Func Right keytop Left + Func 3-2 Right + Func Supported Equipment Manual • March, 2006 Keypad Figures Casio DT-800RF, VT del FNC BS LOCK L R F7 F8 F9 7 8 9 F17 F7 F4 F18 F8 F5 4 F14 F1 F19 F9 F6 5 F24 F15 6 F5 F2 1 F11 PWR F16 F6 F3 2 F21 clear F12 3 F10 F22 ENT 0 CLR F23 F13 F20 F2 F1 vw← F5 F4 F3 vw→ vw↑ F6 vw↓ F7 F8 Left Func Right keytop Left + Func Supported Equipment Manual • March, 2006 Right + Func 3-3 Keypad Configuration Keypad Table The keypad tables in this section are organized by terminal model, keypad configuration, and emulation. The key values represent the default keypad assignments applied to the terminal in Twin Client advanced mode. Table entries that are blank indicate the key is not assigned, or not relevant to the emulation. KEY 1 2 3 4 5 6 7 8 9 0 ATTENTION BACK TAB BACKSPACE BOTTOM CLEAR DELETE DUP ENTER EOF FIELD ADVANCE FIELD EXIT FIELD MINUS FM HELP HOME INSERT LOCK NEWLINE NULLEND NUMBOVR PRINT REDRAW REFRESH RESET ROLL DOWN ROLL UP SPACE STAT SYS REQUEST TAB TOP VIEW DOWN VIEW LEFT VIEW RIGHT VIEW UP PA1 PA2 PA3 F1 F2 3-4 5250 <1> <2> <3> <4> <5> <6> <7> <8> <9> <0> <4> <6> <3> <1> <5> <7> <6> <8> <2> <9> <4> <5> <1> <2> 3270 <1> <2> <3> <4> <5> <6> <7> <8> <9> <0> VT <1> <2> <3> <4> <5> <6> <7> <8> <9> <0> <1> <2> <1> <2> <3> <1> <2> <1> <2> Supported Equipment Manual • March, 2006 Keypad Table F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 F17 F18 F19 F20 F21 F22 F23 F24 . ▲ ▼ ◄ ► dash period <3> <4> <5> <6> <7> <8> <9> <0> <1> <2> <3> <4> <5> <6> <7> <8> <9> <0> <1> <2> <3> <4> Supported Equipment Manual • March, 2006 <3> <4> <5> <6> <7> <8> <9> <0> <1> <2> <3> <4> <5> <6> <7> <8> <9> <0> <1> <2> <3> <4> <3> <4> <5> <6> <7> <8> <9> <0> <1> <2> <3> <4> <5> <6> <7> <8> <9> <0> <1> <2> <3> <4> 3-5 Keypad Configuration This page is intentionally blank. 3-6 Supported Equipment Manual • March, 2006 Chapter 4 • Error Message Resolution Guide Twin Client Error Message Resolution Guide Message Reason ENTRY TOO LONG; Trying to key beyond the field size. Ensure that you are entering input into the correct field. --- ALPHABETIC ONLY; Trying to key a character that is not Ensure that you are entering input into the alphabetic. correct field. --- MINUS NOT VALID; Trying to key a Minus sign. Ensure that you are entering input into the correct field. --- DECIMAL NOT VALID; Trying to key a Decimal (period). Ensure that you are entering input into the correct field. --- ALPHANUMERIC ONLY; Trying to key characters other than Ensure that you are entering input into the Alphabetic and numeric. correct field. --- NUMERIC ONLY; Trying to key characters other than Ensure that you are entering input into the numeric. correct field. --- ENTRY TOO SHORT; Trying to exit the field before it is filled. --- Supported Equipment Manual • March, 2006 Solution Ensure that you are entering input into the correct field. Reference Tech Note 4-1 Error Message Resolution Guide Message Reason Solution Reference Tech Note INVALID KEY; The key pressed is not valid. Ensure that you are entering input into the correct field. --- MUST CLEAR FIELD; Trying to enter data in a field that must be cleared first. Ensure that you are entering input into the correct field. --- SCAN NOT ALLOWED; Trying to scan into a key only field. Ensure that you are entering input into the correct field. --- KEY NOT ALLOWED; Trying to key into a scan only field. Ensure that you are entering input into the correct field. --- ENTRY TOO SHORT; Trying to exit the field before it is filled. Ensure that you are entering input into the correct field. --- RECOVERABLE ERROR; Encountered an error from which you can continue. Verify that your configuration settings for the hardware being used, usually a printer and cable issue. --- UNRECOVERABLE ERROR; Encountered an error from which you can NOT continue. Verify that your Network settings are correct T1113, T1114, T1161, and you are in the correct mode using the T1171, T1187 and correct Port. T1194 FUNCTION: \n\nFILE: \nLINE: \nCODE; Encountered an error from which you can NOT continue. Notify Connect over the WEB incident reporting system. --- Press any key\nFor More Details...; Press Enter for more information. Advisory message. --- Press any key; Press a key to continue. Advisory message. --- 4-2 Supported Equipment Manual • March, 2006 Error Message Resolution Guide Message Reason Solution Reference Tech Note Connection ERROR.\nREBOOT MOBILE UNIT; Could not Connect. Verify that your Network settings are correct T1113, T1114, T1161, and you are in the correct mode using the T1171, T1187 and correct Port. T1194 Disconnect ERROR.\nREBOOT MOBILE UNIT; Could not Disconnect. Verify that your Network settings are correct T1113, T1114, T1161, and you are in the correct mode using the T1171, T1187 and correct Port. T1194 RF Send ERROR.\nREBOOT MOBILE Could not Send. UNIT; Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 RF Receive ERROR.\nREBOOT MOBILE UNIT; Could not Receive. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 RF Check ERROR.\nREBOOT MOBILE UNIT; Could not run the RF Survey. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 RF Timeout ERROR.\nREBOOT MOBILE UNIT; Have been trying to contact the Most likely a range, access point, radio, host for the radio timeout period (2 host or network issue. Troubleshoot the minutes default). customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 REBOOT MOBILE UNIT; Reboot the Mobile Unit do to loss of connection. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Retry (Y/N)?; Try again. Try to send or receive again, or perhaps ensure that the printer is cabled to the Mobile Unit and is on. --- Supported Equipment Manual • March, 2006 4-3 Error Message Resolution Guide Message Reason Solution Reference Tech Note TIMEOUT\n\nSending Data; Mobile Unit out of the coverage area. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 TIMEOUT\n\nReceiving Data; Mobile Unit out of the coverage area. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Host Received Data\nAwaiting App Reply!; Mobile Unit has sent and received an acknowledgement from the IP stack and is waiting for the application to return data. Most likely a host or network issue. Troubleshoot the customer’s environment. Probable causes are Database record locking, application program failure, Host failure or network failure. T1113, T1114, T1161, T1171, T1187 and T1194 * WAITING TO SEND *; Mobile Unit out of the coverage area. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 TCP Error Reading\nMAC Address.\nREBOOT MOBILE UNIT; Could not obtain the Mac Address Possible hardware, driver or stack problem from the Mobile Unit. Contact the Mobile Unit manufacturer. --- Invalid TIP Command; Bad internal protocol. Notify Connect over the WEB incident reporting system. --- Session Ended\nBy User or Host; User, Host, application or network has ended the session. If the user did not end the session, most likely host or network issues. Troubleshoot the customer’s environment. Server Packet Error; Bad Protocol detected. Usually a result of bad cabling, power or faulty transceiver. Also, will receive this if the Mobile Unit is in the wrong mode for server operation. 4-4 T1113, T1114, T1161, T1171, T1187 and T1194 Supported Equipment Manual --- • March, 2006 Error Message Resolution Guide Message Reason Solution Error receiving host\nlist from Server; Bad Protocol detected. --- Unexpected Server\ndata received; Bad Protocol detected. Error starting\nhost application; Connected to the server but can not connect to the distant end. Usually a result of bad cabling, power or faulty transceiver. Also, will receive this if the Mobile Unit is in the wrong mode for server operation. Usually a result of bad cabling, power or faulty transceiver. Also, will receive this if the Mobile Unit is in the wrong mode for server operation. Configure the server handler to access the host application. Select Host or App; Need to choose your Host/application destination. User selection required. --- Connecting...; Attempting to connect to the Host/application. Advisory message. --- TCP Error\nReading IP Address\nREBOOT MOBILE UNIT; Mobile Unit missing Network IP information. Configure the Mobile Unit with the correct network IP information. --- Printer start error; Could not initialize the printer. Cable or power issue with the printer. --- Battery too low\nto print; Not enough power to print. Replace the battery with a fully recharged battery. --- Paper Feed Error\nFix Then Hit Enter; Paper in the printer is not ready. Replace the paper or rethread the paper in the printer. --- Printer Error\nPrint Ended; Can not print. Check cable, battery, communication settings and paper in the printer. --- Supported Equipment Manual • March, 2006 Reference Tech Note --- --- 4-5 Error Message Resolution Guide Message Reason Solution Reference Tech Note User Count Exceeded.\n Session Ended; Possible authorization issue. Verify that you have the correct number of licenses for the number of Mobile Units you are using. --- Primary Unavailable\nTrying Alternate; First Host IP address not available Verify the host address. trying the remaining addresses in the Host list. --- APMAC.DAT Error\nSession Ended; Access point Media Access Control Most likely a range, access point, radio, error. host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 MUIP.DAT Error\nSession Ended; Mobile Unit IP Error. Most likely a Mobile Unit network setting issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Missing Subnet IP\nSession Ended; Mobile Unit IP Netmask Error. Most likely a Mobile Unit network setting issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Error Opening File; File is missing. Verify that the configuration files are on the Mobile Unit. Or perhaps there is a hardware failure. --- Telnet API\nnot found; Program files are missing. Reload program files. --- Battery Low Warning\n\nReplace Battery Soon; Not enough power to operate the Mobile Unit. Replace the battery with a fully recharged battery. --- No Host List.\nPress any key\nTo Edit Host IP's; Have not configured your target hosts. Configure the target host IP addresses. --- Unable to Allocate\nFont Memory; Mobile Unit does not have enough Reduce the fonts in use or expand the memory to load the fonts. memory in the Mobile Unit. 4-6 Supported Equipment Manual --- • March, 2006 Error Message Resolution Guide Message Reason Solution Reference Tech Note Font Loading Error; Could not load the font. Ensure that the font is available to load. --- Printer Not Ready\nPress R to Retry\nC to Cancel Print; Can not print. Check cable, battery, communication settings and paper in the printer. --- Mobile Unit in\nDemonstration Mode\nfor TwinClient; Running in demo mode. Purchase a license from Connect. --- Connected to Host; Successful connection to the target Advisory message. Host. --- Telnet Mode not\nsupported on\nthis Mobile Unit; Telnet Setup files\nnot found. Reload\nfiles then switch; This Mobile Unit must be used with Order a Connect Server. a Connect Server. Customer specific configuration Load the configuration files into the Mobile files are missing. Unit from Twin Client Manager. ----- Switched Client to\nTelnet Direct Mode; Mobile Unit running in Telnet mode Advisory message. direct to the target Host. --- Switched Client to\nServer Based Mode; Mobile Unit running through a Connect server in server mode usually at port 1800. Advisory message. --- Port 23 is only\nallowed in Telnet Mode; Can not set the port to 23 in server Advisory message. mode. Port 23 is the standard Telnet port. --- Not Enough Memory\nTo Run; Mobile Unit does not have the capacity to run the program do to memory restrictions. Expand the Mobile Unit memory. --- Press any key; Press a key to continue. Advisory message. --- Supported Equipment Manual • March, 2006 4-7 Error Message Resolution Guide Message Reason Solution TwinClient Telnet; Prompt. Advisory message. --- TwinClient Server; Prompt. Advisory message. --- TwinClient TN3270; Prompt. Advisory message. --- TwinClient TN5250; Prompt. Advisory message. --- TwinClient TNVT; Prompt. Advisory message. --- (c) 1991-2006 Connect; Prompt. Advisory message. --- Edit Menu Options; Menu Title. Advisory message. --- Edit Mobile Unit IP; Menu Option. Advisory message. --- Edit Server/Host IPs; Menu Option. Advisory message. --- Edit Radio Option; Menu Option. Advisory message. --- 4-8 Reference Tech Note Supported Equipment Manual • March, 2006 Error Message Resolution Guide Message Reason Solution Edit License Key; Menu Option. Advisory message. --- Run Site Survey; Menu Option. Advisory message. --- Switch Client Modes; Menu Option. Advisory message. --- Run TwinClient; Menu Option. Advisory message. --- Exit to OS; Menu Option. Advisory message. --- Printer may not be\nplugged in or\nturned on!; Can not print. Check cable, battery, communication settings and paper in the printer. --- OUT OF RANGE OF BASE; Mobile Unit out of the coverage area. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 CONNECT SERIAL CABLE; Serial cable not connected to the Mobile Unit. Check cable, battery and communication settings for the Mobile Unit. --- REMOVE SERIAL CABLE; Remove serial cable from to the Mobile Unit. Check cable, battery and communication settings for the Mobile Unit. --- PLACE IN CRADLE; Place the Mobile Unit in the cradle. Advisory message. Supported Equipment Manual • March, 2006 Reference Tech Note --- 4-9 Error Message Resolution Guide Message Reason Solution REMOVE FROM CRADLE; Remove Mobile Unit from the cradle. Advisory message. --- ACQUIRING CRADLE BUS; Attempting to access the cradle through the serial port you have configured. Advisory message. --- Printer Out\nOf Range; Printer out of the coverage area. Most likely a range, access point or radio issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Connection Refused\nBy Host; You connected to the target host but the host disconnected you. Verify that the configuration file has the correct Mobile Unit type and New environment variable set. Fallback to the Connect Default to verify the connection. --- Connection Timed Out; You connected to the host but did Modify the Host parameters for login. not logon in the appropriate time so the host disconnected you. Connection Failed\nHost Not Responding; Could not connect to the Host. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Connection Failed\nHost Unreachable; Could not connect to the Host. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Mobile Unit Out\nOf Range, Unable\nTo Transmit; Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 4-10 Mobile Unit out of the coverage area. Reference Tech Note --- Supported Equipment Manual • March, 2006 Error Message Resolution Guide Message Reason Solution Mobile Unit Out\nOf Range, Unable\nTo Receive; Mobile Unit out of the coverage area. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. --- Printer Not\nResponding; Can not print. Check cable, battery, communication settings and paper in the printer. --- Printer Out\nOf Range; Printer out of the coverage area. Most likely a range, access point or radio issue. Troubleshoot the customer’s environment. Print Complete; Prompt. Advisory message. --- Reprint (Y/N)?; Yes or No prompt for a reprint. Advisory message. --- WARNING; Prompt. Advisory message. --- Turning power off\nduring a session\nwill cause the\nprogram to restart; This Mobile Unit will disconnect the Mobile Unit manufacturer limitation. session if powered off. Advisory message. --- Are you sure (y/n)?; Yes or No prompt for a confirmation. Advisory message. --- You Sure? (YyNn); Yes or No prompt for a confirmation. Advisory message. --- Supported Equipment Manual • March, 2006 Reference Tech Note T1113, T1114, T1161, T1171, T1187 and T1194 4-11 Error Message Resolution Guide Message Reason Solution Domain Name Server\nNot Set; DOMAIN NAME SERVER not configured. Configure the Mobile Unit with the correct network IP information. --- Domain Name Server\nQuery Memory Memory error on the Mobile Unit Error; Expand the Mobile Unit memory or return the Mobile Unit for repair. --- Domain Name Server\nQuery Sending Mobile Unit out of the coverage Error; area. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Domain Name Server\nQuery Receive Mobile Unit out of the coverage Error; area. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Domain Name Server\nUnavailable; Could not connect to the DOMAIN Most likely a range, access point, radio, NAME SERVER. host or network issue. Troubleshoot the customer’s environment. T1113, T1114, T1161, T1171, T1187 and T1194 Error loading\nparameter file; Could not load the parameter file. Reload the correct configuration files. --- Could not open\ntelnet interface; Could not telnet. Reload the program files. --- Could not set\mtelnet options; Could not use the telnet configuration. Reload the correct configuration files. --- Setup file\nsetting mismatch\nReload Setup; Emulation program selected is not Remove the emulation and configuration compatible with the configuration files. Run clear Telnet on the Mobile Unit file on the Mobile Unit. then reload the Mobile Unit with the proper emulation and configuration files. 4-12 Reference Tech Note Supported Equipment Manual --- • March, 2006 Error Message Resolution Guide Message Reason Solution Display formatting\ntoo large for\ncurrent screen; Mobile Unit does not have enough Expand the Mobile Unit memory or order a memory to run your configured server from Connect. reformatted screens. --- Mobile Unit\ninitialization error; Mobile Unit problem. --- Return the Mobile Unit to the manufacturer for repair. Reference Tech Note Host/App/Network\nclosed the session; Customer’s environment disconnected the Mobile Unit session. Most likely a range, access point, radio, host or network issue. Troubleshoot the customer’s environment. Disconnecting...; Prompt. Advisory message. --- Scan Barcode; Bar code scanning test. Advisory message. --- Enter Setup\nPassword; Prompt. Advisory message. --- Enter Profile \nPassword; Prompt. Advisory message. --- Host IP; Host IP address prompt. Enter target host IP address. --- Host Name; Host name prompt. Enter target host Name. --- Port; Host IP port required. Enter 23 for telnet or 1800 for a Connect server. Could also be a different number depending on the customer’s environment. Supported Equipment Manual • March, 2006 T1113, T1114, T1161, T1171, T1187 and T1194 T1113, T1114, T1161, T1171, T1187 and T1194 4-13 Error Message Resolution Guide Message Reason Solution Mobile Unit Type; Prompt. Advisory message. --- WARNING: This will \nend any\ncurrent Prompt. session; Advisory message. --- Continue (Y/N)?; Prompt. Advisory message. --- HOST ENTRY; Prompt. Advisory message. --- VT(100/220) Setup; Prompt. Advisory message. --- Mobile Unit Info; Prompt. Advisory message. --- Emulation Setup; Prompt. Advisory message. --- ANSI Setup; Prompt. Advisory message. --- Miscellaneous Setup; Prompt. Advisory message. --- Mobile Unit Type; Prompt. Advisory message. --- 4-14 Reference Tech Note Supported Equipment Manual • March, 2006 Error Message Resolution Guide Message Reason Solution Control Codes; Prompt. Advisory message. --- Local Echo; Prompt. Advisory message. --- Sends; Prompt. Advisory message. --- New Line Mode; Prompt. Advisory message. --- Insert Mode; Prompt. Advisory message. --- Autowrap Mode; Prompt. Advisory message. --- Cursor; Prompt. Advisory message. --- EMULATION SETUP; Prompt. Advisory message. --- Mobile Unit Type; Prompt. Advisory message. --- Local Echo; Prompt. Advisory message. --- Supported Equipment Manual • March, 2006 Reference Tech Note 4-15 Error Message Resolution Guide Message Reason Solution Map Underline; Prompt. Advisory message. --- Break Key; Prompt. Advisory message. --- ANSI Setup; Prompt. Advisory message. --- Control Codes; Prompt. Advisory message. --- Backspace Key; Prompt. Advisory message. --- MISCELLANEOUS SETUP; Prompt. Advisory message. --- Test Options; Prompt. Advisory message. --- Login Options; Prompt. Advisory message. --- TEST OPTIONS; Prompt. Advisory message. --- Printer Test; Prompt. Advisory message. --- 4-16 Reference Tech Note Supported Equipment Manual • March, 2006 Error Message Resolution Guide Message Reason Solution Scan Code Test; Prompt. Advisory message. --- LOGIN OPTIONS; Prompt. Advisory message. --- User Name; Prompt. Advisory message. --- User Password; Prompt. Advisory message. --- ON; Prompt. Advisory message. --- OFF; Prompt. Advisory message. --- Map; Prompt. Advisory message. --- Don't Map; Prompt. Advisory message. --- Enable Break; Prompt. Advisory message. --- Disable Break; Prompt. Advisory message. --- Supported Equipment Manual • March, 2006 Reference Tech Note 4-17 Error Message Resolution Guide Message Reason Solution 7 bit; Prompt. Advisory message. --- 8 bit; Prompt. Advisory message. --- Send Delete; Prompt. Advisory message. --- Send Backspace; Prompt. Advisory message. --- Mobile Unit Setup; Prompt. Advisory message. --- Scanner Options; Prompt. Advisory message. --- Program Options; Prompt. Advisory message. --- Special Options; Prompt. Advisory message. --- Beeper Options; Prompt. Advisory message. --- Exit to DOS; Prompt. Advisory message. --- 4-18 Reference Tech Note Supported Equipment Manual • March, 2006 Error Message Resolution Guide Message Reason Solution Backlight Time; Prompt. Advisory message. --- Enter Key Action; Prompt. Advisory message. --- Reset Options; Prompt. Advisory message. --- Font Size; Prompt. Advisory message. --- Portable Printer; Prompt. Advisory message. --- Reprint Option; Prompt. Advisory message. --- Data IDs; Prompt. Advisory message. --- Internal/External; Prompt. Advisory message. --- Modify Beeps; Prompt. Advisory message. --- Message Beeps; Prompt. Advisory message. --- Supported Equipment Manual • March, 2006 Reference Tech Note 4-19 Error Message Resolution Guide Message Reason Solution Scan Identifier; Prompt. Advisory message. --- AID Scan Setup; Prompt. Advisory message. --- Long Scans; Prompt. Advisory message. --- Scan Send; Prompt. Advisory message. --- Yes; Prompt. Advisory message. --- No; Prompt. Advisory message. --- Normal; Prompt. Advisory message. --- Double Wide; Prompt. Advisory message. --- Double High; Prompt. Advisory message. --- Double High and Wide; Prompt. Advisory message. --- 4-20 Reference Tech Note Supported Equipment Manual • March, 2006 Error Message Resolution Guide Message Reason Solution Errors Only; Prompt. Advisory message. --- Automatic; Prompt. Advisory message. --- All Messages; Prompt. Advisory message. --- Reject; Prompt. Advisory message. --- Truncate; Prompt. Advisory message. --- Split; Prompt. Advisory message. --- Do Not Send; Prompt. Advisory message. --- Always Send; Prompt. Advisory message. --- Last Field Only; Prompt. Advisory message. --- Internal; Prompt. Advisory message. --- Supported Equipment Manual • March, 2006 Reference Tech Note 4-21 Error Message Resolution Guide Message Reason Solution External; Prompt. Advisory message. --- none; Prompt. Advisory message. --- monarch; Prompt. Advisory message. --- pddumb; Prompt. Advisory message. --- comtec; Prompt. Advisory message. --- rascal; Prompt. Advisory message. --- codewriter; Prompt. Advisory message. --- comtec(S); Prompt. Advisory message. --- User Name; Prompt. Advisory message. --- Password; Prompt. Advisory message. --- 4-22 Reference Tech Note Supported Equipment Manual • March, 2006 Error Message Resolution Guide Message Reason Solution Prompt. Advisory message. --- Prompt. Advisory message. --- ms; Prompt. Advisory message. --- Select Scanner; Prompt. Advisory message. --- Setup Scanner; Prompt. Advisory message. --- Scan Test; Prompt. Advisory message. --- Scan Operation; Prompt. Advisory message. --- Laser; Prompt. Advisory message. --- Contact/Pulse; Prompt. Advisory message. --- Contact/No Pulse; Prompt. Advisory message. --- Frequency: Duration: Delay: Hz; ms; Supported Equipment Manual • March, 2006 Reference Tech Note 4-23 Error Message Resolution Guide Message Reason Solution Auto/Pulse; Prompt. Advisory message. --- Auto/No Pulse; Prompt. Advisory message. --- Wand Simulation; Prompt. Advisory message. --- VT100; Prompt. Advisory message. --- VT220; Prompt. Advisory message. --- SETUP; Prompt. Advisory message. --- Mobile Unit IP/Radio; Prompt. Advisory message. --- Host List; Prompt. Advisory message. --- NULL; Prompt. Advisory message. --- 4-24 Reference Tech Note Supported Equipment Manual • March, 2006
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 64 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:8192833b-b509-4dbc-8cee-4dbe9e04277c Producer : Acrobat Distiller 6.0 (Windows) Company : Technical Documentation, Inc. Source Modified : D:20060317164052 Headline : Creator Tool : Acrobat PDFMaker 6.0 for Word Modify Date : 2006:03:17 10:52:40-06:00 Create Date : 2006:03:17 10:41:41-06:00 Metadata Date : 2006:03:17 10:52:40-06:00 Document ID : uuid:c1c67eab-9014-43e6-9217-36ac88b529fd Version ID : 42 Format : application/pdf Title : Creator : Chris Christofferson Subject : Tagged PDF : Yes Author : Chris ChristoffersonEXIF Metadata provided by EXIF.tools