Casio Fx 220Plus Owners Manual 82MS_fx 82SX PLUS_fx 85MS_fx 220 300MS_fx 350MS_Eng

Casio-Fx-220-Plus-Users-Manual-242783 casio-fx-220-plus-users-manual-242783

Fx-82Sx-220Plus-Etc-E fx-82sx-220plus-etc-e

User manual fx-82SX_220PLUS_etc_E Casio fx-220PLUS Calculator User Manuals and Instruction Guides

FX-82SX PLUS fx-82SX_220PLUS_etc_EN

FX-220 PLUS to the manual 31bed75d-f6a5-4387-a237-f4809ad214f6

2015-03-09

: Casio Casio-Fx-220Plus-Owners-Manual-590293 casio-fx-220plus-owners-manual-590293 casio pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadCasio Casio-Fx-220Plus-Owners-Manual- Fx-82MS_fx-82SX PLUS_fx-85MS_fx-220 PLUS_fx-300MS_fx-350MS_Eng  Casio-fx-220plus-owners-manual
Open PDF In BrowserView PDF
fx-82MS
fx-82SX PLUS
fx-85MS
fx-220 PLUS
fx-300MS
fx-350MS

E

6. Removing the Hard Case

Auto Power Off
Your calculator will turn off automatically if you do not perform any
operation for about 10 minutes.

http://edu.casio.com
http://edu.casio.com/forum/

SA0912-A

Printed in China

1. Important Information

2. Sample Operations
Sample operations in this manual are indicated by a
icon. Unless
specifically stated, all sample operations assume that the calculator is
in its initial default setup. Use the procedure under “3. Initializing the
Calculator” to return the calculator to its initial default setup.

3. Initializing the Calculator
Perform the following procedure when you want to initialize the
calculator and return the calculation mode and setup to their initial
default settings. Note that this operation also clears all data currently
in calculator memory.
fx-82MS/85MS/300MS/350MS: p!,(CLR)3(All)=
fx-82SX PLUS/220 PLUS: pr3(All)=

4. Safety Precautions
Battery
• Keep batteries out of the reach of small children.
• Use only the type of battery specified for this calculator in this
manual.

5. Handling Precautions
• Dim figures on the display of the calculator indicate that battery
power is low. Continued use of the calculator when the battery
is low can result in improper operation. Replace the battery
as soon as possible when display figures becomes dim. Even
if the calculator is operating normally, replace the battery at
least once every two years (fx-82MS/82SX PLUS/220 PLUS), or
three years (fx-85MS/300MS/350MS). A dead battery can leak,
causing damage to and malfunction of the calculator. Never
leave a dead battery in the calculator.
• The battery that comes with the calculator discharges slightly
during shipment and storage. Because of this, it may require
replacement sooner than the normal expected battery life.
• Do not use an oxyride battery* or any other type of nickel-based
primary battery with this product. Incompatibility between
such batteries and product specifications can result in shorter
battery life and product malfunction.
• Avoid use and storage of the calculator in areas subjected
to temperature extremes, and large amounts of humidity and
dust.
• Do not subject the calculator to excessive impact, pressure,
or bending.

1. Press the , key a number of times until
you reach the setup screen shown to the
right.
2. Press c.
3. Use d and e to adjust contrast.
4. After the setting is the way you want, press A.
Important: If adjusting display contrast does not improve display
readability, it probably means that battery power is low. Replace
the battery.

Indicators
Input expression

General calculations

N1(COMP)

Standard deviation

N2(SD)

Regression calculations (fx-82MS/85MS/
300MS/350MS only)

N3(REG)

Note: • The initial default calculation mode is the COMP Mode.
• Mode indicators appear in the upper part of the display. Be sure to
check the current calculation mode (COMP, SD, REG) and angle unit
setting (Deg, Rad, Gra) before beginning a calculation.

11. Configuring the Calculator Setup
Pressing the , key more than once displays additional setup
screens. Underlined ( ___ ) settings are initial defaults.
1Deg 2Rad 3Gra Specifies degrees,
radians or grads as the angle unit for value
input and calculation result display.
Note: In this manual, the v symbol next to a sample operation
indicates degrees.
1Fix 2Sci 3Norm
Specifies the
number of digits for display of a calculation
result.
Fix: The value you specify (from 0 to 9) controls the number of decimal
places for displayed calculation results. Calculation results are
rounded off to the specified digit before being displayed.
Example: 100 ÷ 7 = 14.286 (Fix 3)
Sci: The value you specify (from 1 to 10) controls the number of
significant digits for displayed calculation results. Calculation results
are rounded off to the specified digit before being displayed.
Example: 1 ÷ 7 = 1.4286 × 10–1 (Sci 5)
Norm: Selecting one of the two available settings (Norm 1, Norm
2) determines the range in which results will be displayed in nonexponential format. Outside the specified range, results are displayed
using exponential format.
Norm 1: 10–2  |x|, |x|  1010 Norm 2: 10–9  |x|, |x|  1010
Example: 1 ÷ 200 = 5 × 10–3 (Norm 1); 0.005 (Norm 2)
b

e
d

1ab/c 2 d/c Specifies either mixed fraction (ab/c) or improper
fraction (d/c) for display of fractions in calculation results.
1 Dot 2 Comma
Specifies whether to display a dot or a
comma for the calculation result decimal point. A dot is always
displayed during input.

15.

To recall the contents of M
fx-82MS/85MS/300MS/350MS:
(Continuing) tl(M)
fx-82SX PLUS/220 PLUS:
(Continuing) n

35.
35.

Note: Variable M is used for independent memory.

Independent memory and variable contents are retained even if you
press A, change the calculation mode, or turn off the calculator.
Perform the following procedure when you want to clear the contents
of all memories.
fx-82MS/85MS/300MS/350MS: p!,(CLR)1(Mcl)=
fx-82SX PLUS/220 PLUS: pr1(Mcl)=

k Calculation Priority Sequence

k Using Engineering Notation

When the priority of two expressions is the same, the calculation is
performed from left to right.

A simple key operation transforms a displayed value to engineering
notation.

1st

Function with parentheses: Pol(x, y), Rec(r, ),
RanInt#(a, b)* (*fx-82SX PLUS/220 PLUS only)

2nd

Type A functions: With these functions, the value is
entered and then the function key is pressed. (x3, x2, x−1,
x!, ° ’ ”, m, m1, m2, n, °, r, g)

3rd

Powers and roots: ^(xy), x'

4th

Fractions

5th

Implied multiplication of π, e (natural logarithm base),
memory name, or variable name: 2π, 3e, 5A, πA, etc.

6th

Type B functions: With these functions, the function key is
pressed and then the value is entered. (', 3', log, ln,
ex, 10x, sin, cos, tan, sin−1, cos−1, tan−1, sinh, cosh, tanh,
sinh−1, cosh−1, tanh−1, (−))

7th

Implied multiplication of Type B functions: 2'
3, Alog2, etc.

8th

Permutation (nPr), combination (nCr)

9th

Multiplication, division (×, ÷)

To delete a single character or function:
1234_ → ddD → 124
To insert a character or function into a calculation:
123_ → d!D(INS)e → 1243
• The cursor changes from “_” to “t”.
To clear all of the calculation you are inputting: Press A.

2+1 = 1
1
3 2
6

2$3+1$2=

1{1{6.

1 =1
2 2

4-3$1$2=

1{2.

Note: • Mixing fractions and decimal values in a calculation will cause
the result to be displayed as a decimal value. • Fractions in calculation
results are displayed after being reduced to their lowest terms.
To switch a calculation result between improper fraction and
mixed fraction format: Press 1$(d/c).
To switch a calculation result between fraction and decimal
format: Press $.

k Percent Calculations
150 * 20 1=(%)

30.

Calculate what percentage of 880 is 660. (75%)
660 / 880 1=(%)

75.

Increase 2500 by 15%. (2875)
2500 * 15 1=(%)+
Discount 3500 by 25%. (2625)
3500 * 25 1=(%)-

6.Disp
9.

14. Function Calculations

Transform the value 1234 to engineering notation, shifting the
decimal point to the right.
1234.
1234 =
W 1.234×103
W 1234.×100

In the COMP Mode, the calculator remembers up to approximately
150 bytes of data for the newest calculation. You can scroll through
calculation history contents using f and c.
1+1=2
2+2=4
3+3=6

1+1=
2+2=
3+3=
(Scrolls back.) f
(Scrolls back again.) f

2.
4.
6.
4.
2.

π : π is displayed as 3.141592654, but π = 3.14159265358980 is
used for internal calculations.

e (fx-82MS/85MS/300MS/350MS only): e is displayed as
2.718281828, but e = 2.71828182845904 is used for internal
calculations.
sin, cos, tan, sin−1, cos−1, tan−1 : Trigonometric functions. Specify
the angle unit before performing calculations. See 1 .
sinh, cosh, tanh, sinh−1, cosh−1, tanh−1 : Hyperbolic functions. The
angle unit setting does not affect calculations. See 2 .
°, r, g : These functions specify the angle unit. ° specifies degrees,
radians, and g grads. Input a function from the menu that appears
when you perform the following key operation: 1G(DRG').
See 3 .

r

10x, ex : Exponential functions. See
log : Logarithmic function. See

4.

5.

ln : Natural logarithm to base e. See 6 .
x2, x3, ^(xy), ', 3', x', x−1 : Powers, power roots, and

reciprocals. See

7.

Note: Calculation history data is all cleared whenever you press O,
when you change to a different calculation mode, or whenever you
initialize modes and settings.

Pol, Rec : Pol converts rectangular coordinates to polar coordinates,
while Rec converts polar coordinates to rectangular coordinates.
See 8 .

k Replay (Not included on the fx-82SX PLUS)

Pol(x, y) = (r, )

Rec(r, ) = (x, y)

Rectangular
Coordinates (Rec)

Polar
Coordinates (Pol)

4 × 3 + 2.5 = 14.5
4 * 3 + 2.5 =
4 × 3 − 7.1 = 4.9
(Continuing) dYYYY- 7.1 =

k Fraction Calculations

150 × 20% = 30

3 + 3 Sr(:) 3 * 3 =
=

While a calculation result is on the display, you can press d or e
to edit the expression you used for the previous calculation.

13. Basic Calculations

4−3

3+3:3×3

k Calculation History (Not included on the fx-82SX PLUS)

k Correcting and Clearing an Expression

Perform this key
operation:

Convert 2°15´18˝ to its decimal equivalent.
2 $ 15 $ 18 $= 2°15°18.
(Converts sexagesimal to decimal.) $
2.255
(Converts decimal to sexagesimal.) !$(←) 2°15°18.

To subtract the result of 10 + 5 from M
(Continuing) 10 + 5 1l(M–)

k Clearing the Contents of All Memories

10th Addition, subtraction (+, –)

When you want to perform this type of
operation:

3°0°0.

50.

You can use the colon character (:) to connect two or more
expressions and execute them in sequence from left to right when
you press =.

Calculation result

10. Specifying the Calculation Mode

2°20´30˝ + 39´30˝ = 3°00´00˝
2 $ 20 $ 30 $+ 0 $ 39 $ 30 $=

To add the result of 10 × 5 to M
(Continuing) 10 * 5 l

Note: • The memory area used for calculation input can hold 79
“steps”. One step is taken up each time you press a number key
or arithmetic operator key (+, -, *, /). A ! or a (fx82MS/85MS/300MS/350MS only) key operation does not take up a
step, so inputting !W(3'), for example, takes up only one step.
• Whenever you input the 73rd step of any calculation, the cursor
changes from “_” to “k” to let you know memory is running low.

9. Reading the Display
The display of the calculator shows expressions you input, calculation
results, and various indicators.

Note: You must always input something for the degrees and minutes,
even if they are zero.

k Multi-Statements (fx-82MS/85MS/300MS/350MS only)

8. Adjusting Display Contrast

• The displays and illustrations (such as key markings) shown in
this User’s Guide are for illustrative purposes only, and may differ
somewhat from the actual items they represent.
• The contents of this manual are subject to change without notice.
• In no event shall CASIO Computer Co., Ltd. be liable to anyone
for special, collateral, incidental, or consequential damages in
connection with or arising out of the purchase or use of this product
and items that come with it. Moreover, CASIO Computer Co., Ltd.
shall not be liable for any claim of any kind whatsoever by any other
party arising out of the use of this product and the items that come
with it.
• Be sure to keep all user documentation handy for future reference.

LY700-4E_091226.indd 1

4 *s 30 *( 30 + 10 * 3 )=

Press O to turn on the calculator.
Press 1A(OFF) to turn off the calculator.

CASIO EDUCATIONAL FORUM

Perform the following procedure to initialize the calculator, which
returns the calculation mode to COMP and returns all other settings,
including setup menu settings, to their initial defaults.
fx-82MS/85MS/300MS/350MS: p1,(CLR)c(Mode)=
fx-82SX PLUS/220 PLUS: prc(Mode)=

4 × sin30 × (30 + 10 × 3) = 120 v

7. Turning Power On and Off

CASIO Worldwide Education Website

k Initializing Calculator Settings

12. Inputting Expressions and Values

Before using the calculator, slide
its hard case downwards to
remove it, and then affix the hard
case to the back of the calculator
as shown in the illustration
nearby.

User’s Guide

RJA521989-001V01

• Never try to take the calculator apart.
• Use a soft, dry cloth to clean the exterior of the calculator.
• Whenever discarding the calculator or batteries, be sure to
do so in accordance with the laws and regulations in your
particular area.
* Company and product names used in this manual may be registered
trademarks or trademarks of their respective owners.

2875.
2625.

If 300 grams are added to a test sample originally weighing
500 grams, what is the percentage increase in weight?
(160%)
160.
300+500!=(%)
What is the percentage change when a value is increased
from 40 to 46? (15%)
46-40!=(%)
15.

k Degree, Minute, Second (Sexagesimal)
Calculations
The following is the input format for a sexagesimal value: {degrees}
$ {minutes} $ {seconds} $.

14.5
4.9

Specify the angle unit
before performing
calculations.
Calculation result θ is
displayed in the range
of −180°  θ  180°.

k Answer Memory (Ans)

x ! : Factorial function. See

The last calculation result obtained is stored in Ans (answer) memory.
Ans memory contents are updated whenever a new calculation
result is displayed.

Ran# : Generates a 3-digit pseudo random number that is less than
1. See 10.

To divide the result of 3 × 4 by 30
3*4=

123 + 456 =
(Continuing) 789 -G=

RanInt# (fx-82SX PLUS/220 PLUS only): For input of the function
of the form RanInt#(a, b), which generates a random integer within
the range of a to b. See 11.

12.

nPr, nCr : Permutation (nPr) and combination (nCr) functions. See

579.
210.

Rnd : The argument of this function is made a decimal value and
then rounded in accordance with the current number of display digits
setting (Norm, Fix, or Sci). With Norm 1 or Norm 2, the argument is
rounded off to 10 digits. See 13.

12.

(Continuing) / 30 =
123 + 456 = 579
789 – 579 = 210

9.

k Variables (A, B, C, D, E, F, X, Y)
(fx-82MS/85MS/300MS/350MS only)
Your calculator has eight preset variables named A, B, C, D, E, F,
X, and Y.

Note: Using functions can slow down a calculation, which may delay
display of the result. To interrupt an ongoing calculation before its
result appears, press A.

k Examples
v

s 30 =

sin−10.5 = 30° v

1s(sin−1) 0.5 =

1 sin 30°= 0.5
To assign the result of 3 + 5 to variable A
3 + 5 1t(STO)y(A)

8.

To multiply the contents of variable A by 10
(Continuing) Sy(A)* 10 =

80.

To recall the contents of variable A
(Continuing) ty(A)

8.

To clear the contents of variable A
0 1t(STO)y(A)

0.

2

sinh 1 = 1.175201194
cosh–1 1 = 0

ws(sinh) 1 = 1.175201194

w1c(cosh−1) 1 =

3 π /2 radians = 90°, 50 grads = 45°

You can add calculation results to or subtract results from independent
memory. The “M” appears on the display when there is any value
other than zero stored in independent memory.

0.

v

(1E(π)/ 2 )1G(DRG')c(R)=
50 1G(DRG')d(G)=

90.
45.

4 To calculate e5 × 2 to three significant digits (Sci 3)
N

k Independent Memory (M)

0.5
30.

2(Sci)3

5 log 1000 = 3

1i(ex) 5 * 2 = 2.97×102
l 1000 =

3.

6 To calculate ln 90 (= loge 90) to three significant digits (Sci 3)
To clear the contents of M
fx-82MS/85MS/300MS/350MS:
0 1t(STO)l(M)
fx-82SX PLUS/220 PLUS:
0 1n(Min)

N

0.
0.

2(Sci)3

i 90 = 4.50×100

7 1.2 × 103 = 1200

1.2 * 10 M 3 =

(52)3 = 15625

( 5 x)W=

1200.
15625.

09.12.26 10:02:55 AM

51M(x') 32 =
2.
32 = 2
To calculate '
(=
3
=
4.242640687...) to three
'
2
2×3
decimal places (Fix 3)
N 1(Fix)3
12*3=
4.243
5

8 To convert rectangular coordinates ('
2,'
2 ) to polar
coordinates v
fx-82MS/85MS/300MS/350MS:
r = 2.
r9 2 ,9 2 )=
~t(F)
 = 45.
• Press ~c(E) to display the value of r, or ~t(F) to
display the value of .
fx-82SX PLUS/220 PLUS:
r9 2 ((,)9 2 )=
r = 2.
!q(y,)=
 = 45.
• Press ! r ( x , r ) = to display the value of r , or
!q(y,)= to display the value of .
To convert polar coordinates ('
2 , 45°) to rectangular
coordinates v
fx-82MS/85MS/300MS/350MS:
!r(Rec( )9 2 , 45 =
x = 1.
~t(F)
y = 1.
• Press ~c(E) to display the value of x, or ~t(F) to
display the value of y.
fx-82SX PLUS/220 PLUS: q9 2 ((,) 45 =
x = 1.
!q(y, )=
y = 1.
• Press ! r ( x , r ) = to display the value of x , or
!q(y,)= to display the value of y.
9 (5 + 3) ! = 40320

( 5 + 3 )1E(x!)=

40320.

10 To obtain two random three-digit integers
1000 1.(Ran#)=
=

459.
48.

(Actual results will differ.)

11 To generate random integers in the range of 1 to 6 (fx-82SX
PLUS/220 PLUS only)
12(RanInt) 1 1((,) 6 )=
=

2.
6.

(Actual results will differ.)

12 To determine the number of permutations and combinations
possible when selecting four people from a group of 10
Permutations:
Combinations:

10 1{(nPr) 4 =
10 {4 =

5040.
210.

13 To perform the following calculations when Fix 3 is selected
for the number of display digits: 10 ÷ 3 × 3 and Rnd(10 ÷ 3)
×3
N

1(Fix)3
10 / 3 * 3 =
10 / 3 =10(Rnd)* 3 =

10.000
9.999

15. Statistical Calculations (SD, REG*)
*fx-82MS/85MS/300MS/350MS only
To select this type of statistical
calculation: (Regression formula
shown in parentheses)

Perform this key
operation:

Single-variable (X)

,2(SD)

k Data Input Precautions

k Calculating Estimated Values

• While inputting data or after inputting data is complete, you can use
the f and c keys to scroll through data you have input. If you
input multiple entries of the same data using !,(;) (!)(;) on
the fx-82SX PLUS/220 PLUS) to specify the data frequency (number
of data items) as described above, scrolling through data shows
both the data item and a separate screen for the data frequency
(Freq).
• Input the new value and then press the = key to replace the old
value with the new one. This also means that if you want to perform
some other operation, you should always press the A key first to
exit data display.
• Pressing the 7 key instead of = after changing a value on the
display registers the value you input as a new data item, and leaves
the old value as it is.
• You can delete a data value displayed using f and c by pressing
!l(CL). Deleting a data value causes all values following it to
be shifted up.
• The message “Data Full” appears and you will not be able to input
any more data if there is no memory left for data storage. If this
happens, press the = key to display the screen shown below.
Press c to exit data input without registering
the value you just input.
Press b if you want to register the value
you just input. If you do this, however, you will not be able to display
or edit any of the data you have input.
• After inputting statistical data in the SD Mode or REG Mode, you
will be unable to display or edit individual data items any longer
after perform either the following operations: changing to another
mode; changing the regression type.
• Entering the REG Mode and selecting a regression type (Lin, Log,
Exp, Pwr, Inv, Quad) clear variables A through F, X, and Y.
• Do not use variables A through F, X, or Y to store data when
performing statistical calculations.

Based on the regression formula obtained by paired-variable
statistical calculation, the estimated value of y can be calculated for
a given x-value. The corresponding x-value (two values, x1 and x2, in
the case of quadratic regression) also can be calculated for a value
of y in the regression formula.

Supported statistical variables and the keys you should press to recall
them are shown below.
fx-82SX PLUS/220 PLUS:
Sum: Σx2, Σx, Number of Items: n, Mean: o, Population Standard
Deviation: σx , Sample Standard Deviation: sx
!e to j
fx-82MS/85MS/300MS/350MS:
For single-variable statistical calculations, the variables marked with
an asterisk (*) are available.
Sum: Σx2*, Σx*, Σy2, Σy, Σxy, Σx3, Σx2y, Σx4, Number of Items: n*
Σx2, Σx, n ........... !b(S-SUM) b to d
Σy2, Σy, Σxy ........ !b(S-SUM)e b to d
Σx3, Σx2y, Σx4 ..... !b(S-SUM)ee b to d(Quadratic
Regression only)
Mean: o*, p, Population Standard Deviation: σx*, σy, Sample
Standard Deviation: sx*, sy
o, σx , sx .............. !c(S-VAR) b to d
p, σy, sy ............... !c(S-VAR)e b to d
Regression Coefficients: A, B, Correlation Coefficient: r
Regression Coefficients for Quadratic Regression: A, B, C
!c(S-VAR)ee b to d
Estimated Values: m, n
Estimated Values for Quadratic Regression: m1, m2, n
!c(S-VAR)eee b to c (or d)
• m, m1, m2 and n are not variables. They are commands of the type
that take an argument immediately before them. See “Calculating
Estimated Values” for more information.
1 To calculate the mean (o) and population standard
deviation (σx ) for the following data: 55, 54, 51, 55, 53, 53,
54, 52
,c(SD)
55 7 54 7 51 7 55 7 53 77 54 7 52 7
fx-82SX PLUS/220 PLUS:

Paired-variable (X, Y), logarithmic
,3(REG)2(Log)
regression
( y = A + Blnx)

Paired-variable (X, Y), quadratic
,3(REG)e3(Quad)
regression
( y = A + Bx + Cx2)

k Inputting Data
• In the SD Mode and REG Mode, the l key operates as the 7
key.
• Always start data input with ! , (CLR) b (Scl) =
(rb(Scl)= on the fx-82SX PLUS/220 PLUS) to clear statistical
memory.
• Input data using the key sequence shown below.
SD Mode:  7
REG Mode:  ,  7
• 77 inputs the same data twice.
• You can also input multiple entries of the same data using !,(;)
(!)(;) on the fx-82SX PLUS/220 PLUS).

LY700-4E_091226.indd 2

!h(o)=
53.375
!i(σx )= 1.316956719

fx-82MS/85MS/300MS/350MS:
!c(S-VAR)b(o)
53.375
!c(S-VAR)c(σx ) 1.316956719

Paired-variable (X, Y), e
,3(REG)3(Exp)
exponential regression ( y = AeBx )

Paired-variable (X, Y), inverse
,3(REG)e2(Inv)
regression
( y = A + B/x)

Important: Regression coefficient, correlation coefficient, and
estimated value calculations can take considerable time when there
are a large number of data items.

16. Calculation Ranges, Number of
Digits, and Precision
k Calculation Range and Precision
Calculation Range: ±1 × 10–99 to 9.999999999 × 1099 or 0
Number of Digits for Internal Calculation: 15 digits
Precision: In general, ±1 at the 10th digit for a single calculation.
Precision for exponential display is ±1 at the least significant digit.
Errors are cumulative in the case of consecutive calculations.

k Function Calculation Input Ranges and Precision
Functions

2

fx-82MS/85MS/300MS/350MS: To calculate the linear
regression and logarithmic regression correlation
coefficients (r) for the following paired-variable data
and determine the regression formula for the strongest
correlation: (x, y) = (20, 3150), (110, 7310), (200, 8800),
(290, 9310). Specify Fix 3 (three decimal places) for results.
,3(REG)1(Lin) , 1(Fix)3
20, 3150 7 110 , 7310 7 200 , 8800 7 290 ,
9310 7
!2(S-VAR)ee3(r)=
0.923
,3(REG)2(Log)
20 , 3150 7 110 , 7310 7 200 , 8800 7 290 ,
9310 7
!2(S-VAR)ee3(r)=
0.998
!2(S-VAR)ee1(A)=
−3857.984
!2(S-VAR)ee2(B)=
2357.532
Logarithmic Regression Formula:
y = –3857.984 + 2357.532lnx

Input Range
DEG 0  |x|  9 × 109

sinx
cosx

RAD 0  |x|  157079632.7
GRA 0  |x|  1 × 1010

k Obtaining Statistical Values from Input Data

Paired-variable (X, Y), linear
,3(REG)1(Lin)
regression
( y = A + Bx)

Paired-variable (X, Y), power
,3(REG)e1(Pwr)
regression
( y = AxB)

To determine the estimate value for y when x = 160 in the
regression formula produced by logarithmic regression of
the data in 2 . Specify Fix 3 for the result. (Perform the
following operation after completing the operations in 2 .)
8106.898
160 12(S-VAR)eee2(n)=

3

DEG Same as sinx, except when |x| = (2n–1) × 90.
tanx

RAD Same as sinx, except when |x| = (2n–1) × π/2.
GRA

Same as sinx, except when |x| = (2n–1) ×
100.

sin–1x
cos–1x

0  |x|  1

tan–1x

0  |x|  9.999999999 × 1099

sinhx
coshx

0  |x|  230.2585092

sinh–1x

0  |x|  4.999999999 × 1099

cosh–1x

1  x  4.999999999 × 1099

tanhx

0  |x|  9.999999999 × 1099

tanh–1x

0  |x|  9.999999999 × 10–1

logx/lnx

0  x  9.999999999 × 1099

10x
x

e

–9.999999999 × 1099  x  99.99999999
–9.999999999 × 1099  x  230.2585092

x
'

0  x  1 × 10100

x

|x|  1 × 1050

x –1

|x|  1 × 10100; x G 0

3

|x|  1 × 10100

2

x
'
x!

nPr
nCr

0  x  69 (x is an integer)
0  n  1 × 1010, 0  r  n (n, r are integers)
1  {n!/(n–r)!}  1 × 10100
0  n  1 × 1010, 0  r  n (n, r are integers)
1  n!/r!  1 × 10100 or 1  n!/(n–r)!  1 × 10100

Pol(x, y)

|x|, |y|  9.999999999 × 1099
x2 + y2  9.999999999 × 1099

Rec(r, )

0  r  9.999999999 × 1099
: Same as sinx

°’ ”

|a|, b, c  1 × 10100; 0  b, c
The display seconds value is subject to an error of
±1 at the second decimal place.

• Precision is basically the same as that described under “Calculation
Range and Precision”, above.
• Calculations that use any of the functions or settings shown below
require consecutive internal calculations to be performed, which can
cause accumulation of error that occurs with each calculation.
y , 3', x!, nPr, nCr; °, r, g (angle unit: radians); σx, sx, regression
xy, x'
coefficient.
• Error is cumulative and tends to be large in the vicinity of a function’s
singular point and inflection point.
• Accumulation of errors tends to occur during statistical calculations
involving data in which there is a large number of decimal places
and there is little difference between data items. Input of statistical
data is limited to six decimal places.

17. Error Messages
The calculator will display an error message whenever an error occurs
for any reason during a calculation.
• Press d or e to return to the calculation screen. The cursor will
be positioned at the location where the error occurred, ready for
input. Make the necessary corrections to the calculation and execute
it again. (Not included on the fx-82SX PLUS)
• Press A to return to the calculation screen. Note that this also
clears the calculation that contained the error.
Math ERROR
Cause: • The intermediate or final result of the calculation you
are performing exceeds the allowable calculation range. • Your
input exceeds the allowable input range. • The calculation you are
performing contains an illegal mathematical operation (such as
division by zero).
Action: • Check the input values and reduce the number of digits.
• When using independent memory or a variable as the argument of
a function, make sure that the memory or variable value is within the
allowable range for the function.

20. Specifications
Power Requirements:
fx-82MS/82SX PLUS/220 PLUS: AA-size battery R6P (SUM-3) × 1
fx-350MS: Button battery LR44 (GPA76) × 1
fx-85MS/300MS: Built-in solar cell; button battery LR44 (GPA76)
×1
Approximate Battery Life:
fx-82MS/82SX PLUS/220 PLUS: 17,000 hours (continuous display
of flashing cursor)
fx-350MS: 9,000 hours (continuous operation)
fx-85MS/300MS: 3 years (based on one hour of operation per day)
Power Consumption:
0.0001 W (fx-82MS/82SX PLUS/220 PLUS/350MS)
Operating Temperature: 0°C to 40°C (32°F to 104°F)
Dimensions (H × W × D)/Approximate Weight (including the battery)
fx-82MS

18.6 × 85 × 156 mm
3
/4 × 33/8 × 61/8

115 g
(4.1 oz)

fx-82SX PLUS
fx-220 PLUS

19.5 × 78 × 155 mm
3
/4 × 31/8 × 61/8

115 g
(4.1 oz)

fx-85MS
fx-300MS
fx-350MS

1

12.2 × 85 × 155 mm
/2 × 33/8 × 61/8

100 g
(3.5 oz)

Stack ERROR
Cause: The calculation you are performing has caused the capacity
of the numeric stack or the command stack to be exceeded.
Action: • Simplify the calculation expression. • Try splitting the
calculation into two or more parts.
Syntax ERROR
Cause: There is a problem with the format of the calculation you
are performing.
Action: Make necessary corrections.
Arg ERROR
Cause: Improper use of an argument.
Action: Make necessary corrections.

18. Before Assuming Malfunction of the
Calculator...
Perform the following steps whenever an error occurs during a
calculation or when calculation results are not what you expected.
Note that you should make separate copies of important data before
performing these steps.
1. Check the calculation expression to make sure that it does not
contain any errors.
2. Make sure that you are using the correct mode for the type of
calculation you are trying to perform.
3. If the above steps do not correct your problem, press the O
key.
4. Initialize all modes and settings. See “Initializing Calculator
Settings”.

19. Replacing the Battery
Important: Removing the battery will cause all of the calculator’s
memory contents to be deleted.
1. Press 1A(OFF) to turn off the calculator.
• To ensure that you do not accidentally turn on power while
replacing the battery, slide the hard case onto the front of the
calculator (fx-350MS).
2. Remove the cover as shown in the illustration and replace the
battery, taking care that its plus (+) and minus (–) ends are facing
correctly.
Screw
Screw

Screw

Screw

Screw

|x|  1 × 10
Decimal ↔ Sexagesimal Conversions
0°0´0˝  |x|  9999999°59´
100

y

x

x  0: –1 × 10100  ylogx  100
x = 0: y  0
x  0: y = n, 1 (n is an integer)
2n+1
However: –1 × 10100  ylog |x|  100

y
'

y  0: x G 0, –1 × 10100  1/x logy  100
y = 0: x  0
y  0: x = 2n+1, 1 (n G 0; n is an integer)
n
However: –1 × 10100  1/x log |y|  100

a b/c

Total of integer, numerator, and denominator must
be 10 digits or less (including division marks).

RanInt#(a, b)

a  b; |a|, |b|  1 × 1010; b – a  1 × 1010 (a, b are
integers)

x

Manufacturer:
CASIO COMPUTER CO., LTD.
6-2, Hon-machi 1-chome
Shibuya-ku, Tokyo 151-8543, Japan
fx-82MS/82SX PLUS/
220 PLUS

fx-350MS

fx-85MS/300MS

3. Replace the cover.
4. Initialize the calculator. See “3. Initializing the Calculator”.
• Do not skip the above step!

Responsible within the European Union:
CASIO EUROPE GmbH
Casio-Platz 1
22848 Norderstedt, Germany
This mark applies in EU countries only.
RJA521989-001V01

09.12.26 10:02:57 AM



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 2011:07:01 16:09:01+09:00
GTS PDFX Conformance            : PDF/X-1a:2001
GTS PDFX Version                : PDF/X-1:2001
Modify Date                     : 2011:07:01 17:18:33+09:00
Trapped                         : False
Producer                        : Acrobat Distiller 9.0.0 (Macintosh)
Creation Date                   : 2011:07:01 16:09:01+09:00
Mod Date                        : 2011:07:01 17:18:33+09:00
Author                          : CASIO COMPUTER CO., LTD.
Creator Tool                    : Adobe InDesign CS2_J (4.0.5)
Metadata Date                   : 2011:07:01 17:18:33+09:00
Document ID                     : uuid:5cebd400-f1bb-11de-b6c5-001451628961
Instance ID                     : uuid:1b6aa6d4-a040-4c14-8b34-93d0ac8e0a24
Format                          : application/pdf
Creator                         : CASIO COMPUTER CO., LTD.
Title                           : fx-82MS_fx-82SX PLUS_fx-85MS_fx-220 PLUS_fx-300MS_fx-350MS_Eng
Page Count                      : 2
Page Layout                     : OneColumn
EXIF Metadata provided by EXIF.tools

Navigation menu